Home
Manual - EtherWAN
Contents
1. Communication Parameter Settings page 5 1 10 ForceTransmit Settings Please type 10 ForceTransmit Settings and press lt enter gt to enter ForceTransmit page The default ForceTransmit Settings is 0 ms Specify ForceTransmit for the serial port The data will be transmitted when the ForceTransmit is reached ForceTransmit 0 999 ms 0 999 ms Q Exit 1 ForceTransmit Please type 0 999 0 999 ms and press lt enter gt to set ForceTransmit for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 11 Save Config Please type 11 Save Config and press lt enter gt to save configuration Then press any key to exit to Serial Communication Parameter Settings page 20 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 5 1 12 Serial Status Please type 12 Serial Status and press lt enter gt to show status of serial port Then press any key to exit to Serial Communication Parameter Settings page 5 1 13 Exit Please type Q Exit and press lt enter gt to exit to Command page 5 2 Serial Port Status Please type 2 Serial Port Status and press lt enter gt to show status of serial port Then press any key to exit to Command page 5 3 Ring Status Please type 3 Ring Status and press lt ente
2. Serial Communication Parameter Settings page 5 1 2 Baud Rate Settings Please type 2 Baud Rate Settings and press lt enter gt to enter Baud Rate page The default Baud Rate Settings is 9600 bps Baud rate 1 50 11 4800 2 75 12 9600 3 110 13 19200 4 134 14 38400 5 150 15 57600 6 200 16 115200 7 300 17 230400 8 600 18 460800 9 1200 Q Exit 10 2400 1 Baud Rate Please type 1 18 50 460800 bps and press lt enter gt to set Baud rate for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 3 Data Bit Settings Please type 3 Data Bit Settings and press lt enter gt to enter Data bits page The default Data Bit Settings is 8 bits Data bits 15 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 5 2 6 B 7 4 8 Q Exit 1 Data bits Please type 1 4 5 8 bits and press lt enter gt to set Data bits for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 4 Stop Bit Settings Please type 4 Stop Bit Settings and press lt enter gt to enter Stop bits page The default Stop
3. Input Two Terminal Block power inputs ensure the continuous electrical stability DNP3 0 transparency Allows DNP protocol passed through Flexible Installation Method Aluminum housing with panel and DIN Rail mounting Warning Inform user by relay output in case of power failure Simple Configuration Supports DIP switch for Master Local settings Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 3 Console Configuration e Connect to the console port Connect the DB9 straight cable to the RS 232 serial port of the device and the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the console port e Configuration settings of the terminal emulation program Baud rate Data bits Parity Stop bit Flow control 19 200bps 8 none 1 none 19200 HyperTerminal File Edit View Call Transfer Help Dae 6 08 Please choice 1 to 8 Press any key to continue Command 11 1 Config Settings 2 Serial Port status 3 Ring Status 4 Synch Config 5 Reset to default 6 Firmware Version 7 Forward Delay 8 Synch Path Please choice Connected 0 00 35 VT100 19200 8 N 1 TSc Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 4 Self Healing Ring Self
4. Please type 2 No and press lt enter gt to exit to Command page 5 6 Firmware Version Please type 6 Firmware Version and press lt enter gt to show firmware version Then press any key to exit to Command page 5 7 Forward Delay Please type 7 Forward Delay and press lt enter gt to enter Set Forward Delay page The default Forward Delay is 10 seconds Set Forward Delay 10 100 second 10 100 seconds Q Exit 1 Set Forward Delay Please type 10 100 10 100 seconds and press lt enter gt to set Forward Delay for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Command page 5 8 Synch Path Please type 8 Synch Path and press lt enter gt to enter Synch Path page Synch Path 1 Yes 2 No 1 1 Yes 23 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Please type 1 Yes and press lt enter gt to synchronize path 2 2 No Please type 2 No and press lt enter gt to exit to Command page 24 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 6 Specifications 6 1 Overview Applicable IEEE 802 3u 100Base FX Standards Switching Method Store and Forward Forwarding Rate 100Base FX 200Mbps full duplex Performance 148 810pps for 100Mbps Cable 100Base FX 50 or 62 5 125um mul
5. Primary path Primary Ring Green Flashing Ethernet port data transmitting Off No valid connection established S Ring Steady A valid connection through Secondary path Secondary Ring oe Green Flashing Ethernet port data transmitting Off No valid connection established There are Terminal Block power inputs can be used to power up this device Redundant power supplies function is supported Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 1 2 DIN Rail Kits and optional Panel Mounting Kits 1 1 3 DIP Switch Settings DIP switch for Master and Sub master Local mode settings DIP 1 2 switch 1 2 Up Master Function reserved we Sub master Local Down Function reserved Default There should be only one master in a ring and only master supports console configuration 1 1 4 Pin Assignments of Serial Port e DB 9 Pin 1 2 3 4 5 6 z 8 9 RS 232 DCD RxD TxD DTR Signal GND DSR RTS CTS RI RS 422 TxD RxD RxD Signal GND TxD 4 wire RS 485 2 wire RS 485 D D Signal GND Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 2 Functional Description Flexible Serial Ports Supports 2 ports of RS 232 422 485 Dual LAN Ports Supports network connection Self Healing Ring function Fiber Option Supports single mode and multi mode fiber optics for both LAN ports Redundant Power
6. Bit Settings is 1 bit Stop bits 1 1 2 2 Q Exit 1 Stop bits Please type 1 2 1 2 bits and press lt enter gt to set Stop bits for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 5 Parity Settings Please type 5 Parity Settings and press lt enter gt to enter Parity page The default Parity Settings is None Parity 1 None 16 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 2 Odd 3 Even 4 Mark 5 Space Q Exit 1 Parity Please type 1 5 None Odd Even Mark or Space and press lt enter gt to set Parity for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 6 Mode Settings Please type 6 Mode Settings and press lt enter gt to enter Mode page The default Mode Settings is RS232 Mode 1 RS232 2 RS485 3 RS422 Q Exit 1 Mode Please type 1 3 RS232 RS485 or RS422 and press lt enter gt to set Mode for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 7 Flow Control Settings Plea
7. Healing Ring Normal Status Primary Ring gt s master SS master Data flow Se T Fiber Ring f moe Master E 5 P s Master Local Sub master Loest Sub master P s Local Master f el A Sub amaster Fasting as Sub master Mode Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem LED status when Link Failure scenario 2 P Master Local Sub master Data flow ov Master Local Sub master P s i ma a Pe Master Local Sub master Data flow v Local Sub master P s Master Local Sub master ES Flashing as Sub master Mode P s Master Local Sub master P s RS 232 Master Loeal Sub master 1 1 1 1 1 1 1 2 1 1 3 1 1 4 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Table of Contents Quick Start Guide Physical Description The Port Status LEDs and Power Inputs DIN Rail Kits and optional Panel Mounting Kits DIP Switch Settings scsssssees Pin Assignments of Serial Port Functional Description Console Configuration Self Healing Ring Table of Conte nts sccccsssccssssscssssccsssscsesssecssssscccsssscccssscees TNC OMUCHOM sicssssscsnsstestesetscesesacecedecssasciestestaseedeconssebecssansseaseetete Overview Features Getting Started Packaging Interfaces Console Configuration C
8. Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 1 Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Self Healing Ring Fiber Modem Capable of operating at temperature extremes of 10 C to 60 C 1 1 Physical Description 1 1 1 The Port Status LEDs and Power Inputs clo P s ee o 2 U U _ Ay ONO ONO jee na o el o f Power Input Assignment 12 32VDC Power1 Power Ground Power2 12 32VDC Terminal Block Power Ground Earth Ground Relay Alarm Assignment Warning signal disable for following Relay The relay contact closes if Power1 and or Power2 are failed Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem LED State Indication System Power 1 Steady Power on Power 2 Green Off Power off Status Steady Functioned Green Flashing Reset Fault Steady Power or port link fails Orange 7 Off Well Functioned Machine mode Master Steady Master Mode Green Off Off status Sub master Local Steady Local Mode Green Flashing Sub master mode Off Off status Serial port Port 1 TX RX Flashing Data transmitting Port 2 TX RX Ethernet port 100Base FX P Ring Steady A valid connection through
9. and press lt enter gt to enter Protocol Timeout Detect page The default ProtocolTimeoutDetect Settings is Disable Protocol Timeout Detect 1 Enable 2 Disable Q Exit 1 1 Enable Please type 1 Enable and press lt enter gt to enter Set Protocol Timeout page and enable Industrial Serial Self Healing Ring Fiber Modem to automatically test the TCP connection to remote host If the TCP connection is idle the TCP connection will be closed and the serial port will be freed for other hosts Set Protocol Timeout 0 99 ms 0 99 ms Q Exit 0 99 ms Type a period of Protocol Timeout assigned to the serial port on the Industrial Serial Self Healing Ring Fiber Modem The connection will be closed and the serial port will be freed for connection with other hosts when serial port stops data transmission for a defined period of time Protocol Timeout The default Protocol Timeout is 0 ms Q Exit Please type Q and press lt enter gt to exit to Serial Communication Parameter Settings page 2 2 Disable Please type 2 Disable and press lt enter gt to disable 14 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Industrial Serial Self Healing Ring Fiber Modem to automatically test the TCP connection to remote host 3 Q Exit Please type Q Exit and press lt enter gt to exit to
10. ice 1 to 8 Press any key to continue Command 11 1 Config Settings 2 Serial Port status 3 Ring Status 4 Synch Config 5 Reset to default 6 Firmware Version 7 Forward Delay 8 Synch Path Please choice Connected 0 00 35 VT100 19200 8 N 1 TSc 12 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 5 Console Configuration 2 19200 HyperTerminal BEE File Edit View Call Transfer Help De 3 085 amp Please choice 1 to 8 Press any key to continue LL Command 13 1 Config Settings S Reset to default 6 Firmware Version 7 Forward Delay 8 Synch Path Please choice Connected 0 00 35 VT100 5 19200 8 N 1 SCROLL Command page 5 1 Config Settings Please type 1 Config Settings and press lt enter gt to enter Serial Communication Parameter Settings page Serial Communication Parameter Settings 1 ProtocolTimeoutDetect Settings 2 Baud Rate Settings 3 Data Bit Settings 4 Stop Bit Settings 5 Parity Settings 6 Mode Settings 7 Flow Control Settings 8 Use Delimiter 1 Settings 9 Use Delimiter 2 Settings 10 ForceTransmit Settings 11 Save Config 12 Serial Status 13 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Q Exit 5 1 1 ProtocolTimeoutDetect Settings Please type 1 ProtocolTimeoutDetect Settings
11. nt Power Input Two Terminal Block power inputs ensure the continuous electrical stability e DNP3 0 transparency Allows DNP protocol passed through e Flexible Installation Method Aluminum housing with panel and DIN Rail mounting e Warning Inform user by relay output in case of power failure e Simple Configuration Supports DIP switch for Master Local settings Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 4 Getting Started 4 1 Packaging e Industrial Serial to Ethernet Fiber Modem x 1 e Industrial Serial to Ethernet Fiber Modem Quick Start Guide x 1 e Product CD containing user s manual x 1 4 2 Interfaces rll o PY S e of oe U u DpswT 17 AR OVO OVO e e Hoy pi o Sny Industrial Serial to Ethernet Fiber Modem Interfaces LED State Indication System Power 1 Steady Power on Power 2 Green Off Power off Status Steady Functioned Green Flashing Reset Fault Steady Power or port link fails Orange F Off Well Functioned Machine mode 10 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Master Steady Master Mode Green Off Off status Sub master Local Steady Local Mode Green Flashing Sub master mode Off Off status Serial port Port 1 TX RX Flashing Data transmitting P
12. onsole Configuration 13 Config Settings ProtocolTimeoutDetect Settings Baud Rate Settings Data Bit Settings Stop Bit Settings Parity Settings Mode Settings Flow Control Settings Use Delimiter 1 Settings Use Delimiter 2 Settings ForceTransmit Settings Save Config Serial Status Serial Port Status Ring Status Synch Config Reset To Default Firmware Version Forward Delay Synch Path Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 3 Introduction 3 1 Overview This Industrial Serial to Ethernet Fiber Modem is a two serial ports to two Ethernet ports Industrial Self Healing Ring Fiber Modem It is an easy and reliable solution for bringing your serial based equipments to the Fast Ethernet networks This Industrial Serial to Ethernet Fiber Modem supports ring topology and an ability of auto switch to other data path when either link path fails The Self Healing Ring solution ensures the data is uninterrupted and in time notice administrator when any link fails This function provides redundant network connection for the serial devices connected to this Industrial Serial to Ethernet Fiber Modem 3 2 Features e Flexible Serial Ports Supports 2 ports of RS 232 422 485 e Dual LAN Ports Supports network connection Self Healing Ring function e Fiber Option Supports single mode and multi mode fiber optics for both LAN ports e Redunda
13. ort 2 TX RX Ethernet port 100Base FX P Ring Steady A valid connection through Primary path Primary Ring Green Flashing Ethernet port data transmitting Off No valid connection established S Ring Steady A valid connection through Secondary path Secondary Ring ae Green Flashing Ethernet port data transmitting Off No valid connection established Power Input Assignment 12 32VDC Power1 Power Ground Power2 12 32VDC Terminal Block Power Ground Earth Ground Relay Alarm Assignment Warning signal disable for following Relay The relay contact closes if Power1 and or Power2 are failed 11 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 4 3 Console Configuration e Connect to the console port Connect the DB9 straight cable to the RS 232 serial port of the device and the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the console port e Configuration settings of the terminal emulation program Baud rate Data bits Parity Stop bit Flow control 19 200bps 8 none 1 none 19200 HyperTerminal File Edit View Call Transfer Help Dae 6 08 Please cho
14. r gt to enter MACs on the ring page MACs on the ring 1 All MACs 2 Refresh ring status Q Exit 5 3 1 All MACs Please type 1 All MACs and press lt enter gt to show all MAC addresses on the ring 5 3 2 Refresh Ring Status Please type 2 Refresh ring status and press lt enter gt to refresh ring status Then press any key to exit to MACs on the ring page 21 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 5 3 3 Exit Please type Q Exit and press lt enter gt to exit to Command page 5 4 Synch Config Please type 4 Synch Config and press lt enter gt to enter Synch Config page Synch Config H Yes 2 No 1 1 Yes Please type 1 Yes and press lt enter gt to synchronize configuration Then press any key to exit to Command page 2 2 No Please type 2 No and press lt enter gt to exit to Command page 5 5 Reset To Default Please type 5 Reset to default and press lt enter gt to enter Reset to default page Reset to default 1 Yes 2 No 1 1 Yes Please type 1 Yes and press lt enter gt to reset to default This Industrial Serial to Ethernet Fiber Modem will reboot and back to Command page 22 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 2 2 No
15. r gt to exit to Serial Communication Parameter Settings page 2 2 Disable Please type 2 Disable and press lt enter gt to disable Use Delimiter 1 Settings 3 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 9 Use Delimiter 2 Settings Please type 9 Use Delimiter 2 Settings and press lt enter gt to enter Delimiter 2 page The default Use Delimiter 2 Settings is Disable Enable Delimiter 1 The data will be transmitted if the Delimiter 1 is received Enable Delimiter 1 and Delimiter 2 The data will be transmitted if the Delimiter 1 and Delimiter 2 are received Delimiter 2 1 Enable 2 Disable Q Exit 1 1 Enable Please type 1 Enable and press lt enter gt to enter Set Delimiter 2 page Set Delimiter 2 00 ff hex 00 ff Q Exit 00 ff hex Please type 00 ff and press lt enter gt to set Delimiter 2 for serial port Q Exit 19 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Please type Q and press lt enter gt to exit to Serial Communication Parameter Settings page 2 2 Disable Please type 2 Disable and press lt enter gt to disable Use Delimiter 2 Settings 3 Q Exit Please type Q Exit and press lt enter gt to exit to Serial
16. se type 7 Flow Control Settings and press lt enter gt to enter Flow control page The default Flow Control Settings is None 17 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Flow control 1 None 2 Hardware 3 Software Q Exit 1 Flow control Please type 1 3 None Hardware or Software and press lt enter gt to set Flow control for serial port 2 Q Exit Please type Q Exit and press lt enter gt to exit to Serial Communication Parameter Settings page 5 1 8 Use Delimiter 1 Settings Please type 8 Use Delimiter 1 Settings and press lt enter gt to enter Delimiter 1 page The default Use Delimiter 1 Settings is Disable Enable Delimiter 1 The data will be transmitted if the Delimiter 1 is received Enable Delimiter 1 and Delimiter 2 The data will be transmitted if the Delimiter 1 and Delimiter 2 are received Delimiter 1 1 Enable 2 Disable Q Exit 1 1 Enable Please type 1 Enable and press lt enter gt to enter Set Delimiter 1 page Set Delimiter 1 00 ff hex 00 ff Q Exit 00 ff hex Please type 00 ff and press lt enter gt to set Delimiter 1 for serial port 18 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem Q Exit Please type Q and press lt ente
17. ti mode fiber 1310nm up to 2km 9 or 10 125um single mode fiber 1310nm up to 75km Serial Port Interface RS 232 422 485 Connector DB9 2 port RS 232 422 485 Serial Communication Parameters Parity None Even Odd Mark Space Data Bits 5 6 7 8 Stop Bit 1 2 Flow Control None Hardware Software Speed 50bps to 460 8Kbps LED Indicators Per unit Power status Power 1 2 Status Fault Master Sub master Local Ethernet port P Ring Primary Ring S Ring Secondary Ring Serial port Port 1 TX RX Port 2 TX RX Dimensions 100mm W x 125mm D x 30mm H 3 94 W x 4 92 D x 1 18 H Net Weight 0 3Kg 0 66lb Power Input Terminal Block 12 32VDC Power 5 76W Max 0 48A 12VDC 0 24A 24VDC Consumption Operating 10 C to 60 C 14 F to 140 F Temperature Storage 20 C to 85 C 4F to 185 F Temperature Humidity 5 95 non condensing Emission CE Mark Class A Compliance FCC Part 15 Class A VCCI Class A 25 Industrial 2 port RS 232 422 485 Self Healing Ring Fiber Modem 6 2 Pin Assignments Pin assignments for serial port DB 9 RS 422 Pin RS 232 4 wire RS 485 2 wire RS 485 1 DCD TxD 2 RxD RxD D 3 TxD RxD D 4 DTR 5 Signal GND Signal GND Signal GND 6 DSR 7 RTS TxD 8 CTS 9 RI 26