Home
RACETIME 2 - Microgate
Contents
1. if the test is interrupted the data acquired up to this point is NOT saved The sequence described above 15 repeated for each of the tests set after which the statistical values are displayed in the ways previously described MICRO Q GATE Racetime 2 OptoJump Program A N modules 6 Start manual C Timeout 0s A B C more A Min step len 41 cm B Entrance Fr Inter C Autom acquis No A B C esc User manual 16 5 10 F2 Walkjump As well as contact and flight times the WalkJump test makes it possible to acquire data for the length of the steps taken during a run To obtain significant data it is essential to use a certain number of OptoJump modules connected to each other and then positioned along the sides of the test track After selecting WalkJump with F2 the following current system settings are displayed Number of modules press Fl to modify the value set specify the number of connected modules used for the test For the acquisition of step length data to be correct this value must correspond exactly to the number of modules installed Start mode press F2 to modify the value set specify manual if data acquisition is started by a signal on the starting line for example by a photocell situated at the beginning of the measurement base or by pressing the start key Select autom if you wish data acquisition to begin automatically when the athlete being tested enters the tes
2. If all values is chosen the average values of the measurements acquired flight times contact times etc are calculated on the basis of all the values acquired during the single test If the other hand excl min max is chosen the values for the jumps in which the minimum and maximum flight time has been measured will be excluded Note the exclusion of the minimum and maximum values occurs only if at least two jumps with flight and contact times different from zero exist i e if at least two jumps starting from inside the measurement base have been made or three jumps if the jumps are made outside the measurement base To modify your choice press F1 repeatedly F2 Key beep on off Select to deactivate beep emission when the keys are pressed To modify your choice press F2 repeatedly To return to the first screen display of the main menu press F4 MICRO Q Racetime 2 OptoJump Program A Preconf Tests CE B Jump test lt lt C Jump test time A B C more A Acoustic react CE B WalkJump lt lt C RollJump A B C menu User manual 9 5 New tests From this menu you can select the various types of test that you wish to make Press CE to return to the main menu MICRO Q GATE Racetime 2 OptoJump Program A SquatJump B CMJ C CMJ FA B A Technical test B Stiffness C Stiffness FA A B A Jump time 15s CE B Jump time 30s ce C Jump time 60s
3. menu Jump 0 Tc 0000 Tf 0000 5 Hei 00 0cm Rh 000j m 0 00 000 Acquisition Of step length Warning difference between acquired times and acquired steps User manual 17 5 11 When F4 esc is pressed the athlete s number and the number of the test for the trial to be performed are displayed Important the combination athlete s code test number is a single item that is to say Racetime 2 does not allow the same athlete to perform two tests indicated by the same test number To modify the athlete s code and or test number press F2 Edit Press F3 Impos to go back to modify the WalkJump test settings Press to confirm the settings and go on to the performance of the test Before each data acquisition the modules are initialized During initialization a message Please wait briefly appears It is important that the measurement area should not be crossed after acquisition before the start of the test otherwise the acquisition of step length may be incorrect When initialization is terminated the system is ready for acquisition which will begin when a START signal is received if manual start has been chosen or when the athlete being tested enters the measurement area if automatic start has been chosen The test finishes when another START signal is received if timeout is set to zero or after the time set as timeout from the start of the test has expired The te
4. number of jumps set is also given To go on to the next test press esc The values of the test performed are of course memorized for subsequent printing To obtain a printout of the values measured press F2 print for each jump contact time flight time height and instantaneous rhythm are printed The average values for some measurements are given as well as strength and work Note printing takes place automatically when you pass to the next test if the automatic print mode has been set see chap 4 MICRO QJ GATE Racetime 2 OptoJump Program JumpN 1 Tc 0589 Tf 0649ms Hei 51 7cm Rh 48j m esc clear 1T 3 JtiE 10j Tcm 0469 Tfm0487ms Heim30 4cm 62j m T 9 570 clear gt User manual 13 5 6 Press F3 values to pass to the screen display of the single jumps press keys J and T to view the next or previous jump respectively F2 clear eliminates the jump displayed Attention it is not possible to annul elimination F1 esc returns you to the display of average values 3 57 By pressing F4 you enter a second screen display in which you can see the average values for contact time flight time height and rhythm as well as the real duration of the test calculated from the first departure from the ground until the last contact with it if the start is from outside the measurement area if on the other hand the start takes place from inside the measurement area the first departu
5. operating life To recharge the batteries connect the Racetime 2 battery recharger to the corresponding socket on the back of the device If the chronometer is off information on the current status of the battery recharge management function will be immediately shown on the display Specifically the following messages will appear on the first line of the display 7 1 1 1 Status message Function description LED status Maintenance the chronometer is supplied by an external Brief blinking every power source and simultaneously the four seconds batteries are kept fresh by a weak recharge current Discharge at the beginning of a recharge cycle the LED continuously lit batteries are completely run down before being recharged Recharge recharge in progress On the first line of Blinking LED the display the time still to go until the end of recharge is shown If you see the letters Vext Ins blinking on the first line of the display this means that the voltage supplied at the recharge supply input is insufficient Attention when external power is insufficient recharging is interrupted so cannot be completed correctly and within the time anticipated 7 1 If the chronometer is in Maintenance press Rep charge disch to begin a new charge cycle This will start the running down of the batteries The duration of this discharge phase is variable and depends on how fully the batteries are charged The time
6. 99 starts from 1 N jumps or 4 If length in seconds Daytime start 9 HHMMSSdem includes the daytime of the test s beginning Never know 3 Reserved for future use Average ground contact time 5 in milliseconds Average flight time 5 in milliseconds Average rhythm 3 in jumps minute Average heigth 5 in millimeters lt 00999 Average length 5 in millimeters Specific power 5 in hundredths of W Kg Specific Work 5 in hundredths of Cal Kg Test length 6 MSSdcm TAB 1 9 09h Tabulator begin loop jumps Ground contact times 5 in milliseconds Flight times 5 in milliseconds Rhythm 3 in jumps minute Heigth 5 in millimeters lt 00999 Length 5 in millimeters LF 1 10 0Ah Line Feed end loop jumps CR 1 13 0Dh Carriage Return end loop test ETX 1 3 03h End of Text Checksum 1 Zascii module 128 MICRO QJ GATE 10 Appendix 2 Formulas for the calculation of power and work g i gt Bow Os bI ME 4 N sati gt Donato g XII 4 186 8 Specif power W Kg g gravitational force Specific work Cal Kg GATE Microgate S r l Via J Kravogl 8 39100 BOLZANO
7. A B Athlete 1 Test N 1 C more C menu Start from inside OK Edit Setup menu User manual 10 5 1 F1 Preconfigured tests Enables you to choose tests in which the mode of operation is predefined it is therefore not necessary to specify the number of jumps to be made the duration of the test or the start mode from inside or outside the measurement area Below you will find a list of the acquisition modes of the preconfigured tests Many tests have the same acquisition sequences They are dealt with separately so as to distinguish between the various tests according to the different body movements arms free arms at sides etc involved in each one Squatjump CMJ Countermovement CMJ FA Countermovement arms free Technical test 3 jumps starting from inside the measurement area Stiffness stiffness FA arms free 7 jumps starting from outside the measurement area Jump time 15 30 60s test with predefined duration of 15 30 60s starting from inside the measurement area After selecting the type of test you wish to perform you will see the number of the athlete and the number of the test for the trial you will carry out Important the combination athlete s code number of test is a single item which means that Racetime 2 does not allow the same athlete to perform two tests indicated by the same test number To modify the athlete s and or the test number press F2 Edit Press F3 Impo
8. RACETIME 2 OptoJump Program User Manual Microgate S r l Via J Kravogl 8 39100 BOLZANO Racetime 2 OptoJump Program User manual 2 Index MICRO Q GATE Racetime 2 OptoJump Program 1 Introduction User manual 3 The Optojump program for Racetime functions along the same lines as the Optojump program for PC with which it is totally compatible in this sense that it allows the transference of data acquired with Racetime 2 to the personal computer for subsequent elaboration and storage of the data 2 Connecting the OptoJump system Make sure that the Optojump modules are correctly aligned as indicated in the Optojump system assembly instructions Connect the cable coming from the interface battery for Optojump to the socket located at the rear of the Racetime 2 chronometer using the appropriate 9 pole 15 pole adaptor Now the system is ready to function Microgate Italy RACETIME2 Vxx y zz Ch HEH SiH Data are not valid Press enter Yes No System locked Contact Microgate Yes No Clear all stored data Yes No 3 Switching on Racetime 2 initialization Switch on Racetime 2 with the switch located on the back of the device The display will show several items of information about the software version installed on your Racetime 2 and the serial number of the device If you have to contact Microgate for any information or about any problems always give the serial number of
9. ables you to call up all the tests For example if you set 0 as the athlete s number and 1 as the test number the N 1 tests of all the athletes memorized will be displayed To modify the athlete s code and or test number press F2 Edit To confirm the settings press F1 OK 6 2 At this point you will see displayed the power and work values for the Jumptest jumps and Jumptest time tests only power for acoustic reaction tests or average length for the WalkJump or RollJump tests In the upper part of the display the athlete s number and the test number continue to be displayed together with the type of test according to the following code JnbE b JumpTest N jumps external start jumps JnbI b JumpTest N jumps internal start n jumps JteE 5 JumpTest time external start Z test duration Jtel 5 JumpTest time external start test duration Walk WalkJump Roll RollJump speed of mobile running board Press J or T to call up the other tests which correspond to the athlete s number and test number previously set Press F1 esc to return to the selection menu for the tests performed MICRO Q GATE Racetime 2 OptoJump Program Jump N 1 Tc 0589 Tf 0649ms Hei 51 7cm Rh 48j m esc clear N 1T 3 JtiE 10j Tcm 0469 Tfm0487ms Heim30 4cm Rhm 62j m T 9 570 clear User manual 21 Press F2 print to obtain a printout of all the valu
10. act and flight times during the run Step length is calculated for a known running board speed Operating modes and the data displayed are analogous to those of the WalkJump test Before starting the test the speed of the running board must be specified To start the test press the START key To finish it press START again Note the test can be started and concluded also when the athlete being tested is running In this case the length of individual steps is also displayed during data acquisition MICRO Q GATE Racetime 2 OptoJump Program A Preconfig Tests CE B Jump test lt lt C Jump test time M A B C more Athlete 0 Test N 0 O all OK Edit N 1T 3 JtiE 10j Power 23 87 W Kg Work 7 13 Cal Kg esc print values gt User manual 20 6 Tests performed Select this option to display print or delete afterwards tests previously performed Press CE to return to the main menu Attention if Racetime 2 finds no tests memorized the message Not found appears and it is not possible to enter the Tests performed mode First choose the type of test you wish to view The choices possible are obviously the same as those already listed in chapter 5 New tests An Memory on the third line of the display reminds us that we are in Display tests performed mode 6 1 After selecting the type of test set the athlete and the number of test you wish to view The number 0 zero en
11. calculation mode on all values Number of WalkJump modules 6 WalkJump start mode manual WalkJump timeout 05 deactivated WalkJump step minimum length 41cm WalkJump direction entrance from interface side WalkJump automatic acquisition deactivated e OptoJump test start from inside measurement base The meaning of each parameter will be clear when you have become familiar with the different types of test which are described in the following pages MICRO Q Racetime 2 OptoJump Program A New tests B Stored tests C Data transmission A B C more 5 1 6 1 4 1 F1 Start data transm Start User manual 5 4 Main menu After choosing the OptoJump program on the chronometer see chapter 3 choosing the program is obviously not necessary if your Racetime 2 is equipped with only the OptoJump program you enter the main menu from which it is possible to access all the available functions F1 New tests To enter the menu for the selection of the tests to be performed chap 5 F2 Tests done To access the menu for the display of previously memorized tests chap 6 Data transmission Activates the transmission of memorized data to the PC Connect the PC to Racetime 2 with the appropriate cable Cod CAB046 or Cod CAB047 Cod CAB001 and press F1 Start to confirm the start of transmission The memorized data is transmitted according to the protocol given in the Appendix For recept
12. echarging Racetime2 becomes slightly but noticeably warm This is absolutely normal It is also possible to access these functions when the chronometer is on In this way you can begin to recharge the device without interrupting your timing session To access recharge management choose Recharge from the third screen display of the main menu Flat batteries warning When the batteries have nearly run down completely and an external power source is not connected a warning symbol blinks in the upper part of the display From the time the symbol begins to blink you still have a considerable amount of time to finish your work nearly two hours without using the printer but much less if the printer is used frequently If it is not possible to quickly connect the chronometer to an external power source it might be better to disconnect the printer see para C8 10 in order to increase remaining autonomous functioning Remember that when fully charged the batteries can be used continuously for approximately 8 9 hours if the printout of a time is made every 20 seconds Length of duration may be less in particularly harsh climatic conditions or if the batteries are worn out It is absolutely normal for battery efficiency to decline after approximately 500 1000 recharge cycles If you notice a significant reduction in the duration of the batteries please contact Microgate for replacements A New tests B Stored tests C Da
13. es for the test displayed both average values and data for the single jump 6 3 Press F3 values to pass to the screen display of the single jumps press keys J and T to view the next or previous jump respectively F2 clear eliminates the jump displayed Attention it is not possible to annul elimination F1 esc returns you to the display of average values 6 4 By pressing F4 you enter a second screen display in which you can see the average values for contact time flight time height and rhythm as well as the real duration of the test calculated from the first departure from the ground until the last contact with it if the start is from outside the measurement area If on the other hand the start takes place from inside the measurement area the first departure from the ground is taken as the moment of the start From this screen display it is possible to completely eliminate the test performed by pressing F3 Attention it is not possible to annul elimination Press F4 again to return to the previous screen display MICRO Q GATE Racetime 2 OptoJump Program User manual 22 7 Recharging batteries The recharging of Racetime2 s internal batteries is managed entirely by the microprocessor which controls all of the chronometer s functions Consequently it has been possible to implement a recharge control which guarantees maximum battery efficiency at all times at the same time prolonging the chronometer s
14. i 46 9cm Rh 72j m T 0 03 371 Jump N 10 Tc 0235 Tf 0471ms Hei 27 2cm Rh 64j m T 9 570 CleTst OK N 1T 3 JtiE 10j Power 23 87 W Kg 7 13 Cal Kg values gt Work esc print User manual 12 5 4 At this point Racetime 2 is waiting for the start of the test If the athlete s position does not correspond to the start type settings from inside or outside the measurement base an error message is displayed During performance of the test the following information is displayed e Serial jump number Contact time for the present jump Flight time Height of jump shift of center of gravity of the athlete being tested Instantaneous rhythm in jumps minutes In the lower part of the display a running time indicator shows how much time has passed since the start of the test The end of the test is signaled by a beep The test can be interrupted before completion by pressing CE Attention if the test is interrupted the data acquired up to this point is NOT saved It is possible to confirm by pressing F4 OK or to annul the whole test by pressing F3 CleTst 5 5 If the test is confirmed F4 the specific power W Kg developed during the test and the specific work Cal Kg performed are displayed On the first line of the display appear the athlete s code and the test number and test type with the following meaning JnbE Jumptest jumps external start JnbI Jumptest jumps internal start After this the
15. ion we recommend you use the OptoJump program on PC versions 3 20 and subsequent In this way the transferred data will be stored and can be viewed as if it had been acquired directly with the Personal Computer MICRO Q GATE Racetime 2 OptoJump Program User manual 6 4 1 F1 Synchronization Allows you to synchronize Racetime A Synchronisation 2 s internal clock This function should be used when you B Test WalkJump base employ two or more Racetime 2 systems in WalkJump mode C Automatic print Yes with automatic acquisition See chap 5 10 for further A B C more information Automatic printout Yes No Select Yes if you want the tests performed to be printed automatically after they have been confirmed Modify your choice Yes No by pressing F3 repeatedly Set the exact time and confirm with F3 OK To correct the Input daytime setting press F2 Edit 0 00 00 000 Edit OK menu Press START or activate the START input to synchronize the Input daytime internal clock 0 00 00 000 START to synchronize MICRO Q GATE Racetime 2 OptoJump Program N modules 6 Get out from base F2 start test Nmod Test WalkJump Base User manual 7 4 2 F2 WalkJump test base This functions allows you to verify the correct alignment of the OptoJump bars when two or more modules have been connected to each other for the acquisition of contact and flight times and
16. needed to discharge can last up to four hours After discharging the batteries Racetime2 will automatically begin to recharge this takes seven hours After recharging the words Charging over indicate that the process has Discharging been correctly completed If however battery malfunction A Imediate charge has caused premature interruption of charging the messages B Break process Err Batteries LV insufficient battery voltage or Err A B Batteries HV battery voltage too high will appear Trickle charge A rep charge disch A menu MICRO QJ GATE Racetime 2 OptoJump Program User manual 23 52 During discharging it is possible at any time to go straight Charging 7 00 00 over to charging by pressing F1 A Rep charge disch This A rep charge disch will shorten the time needed for recharging However you are B Break process advised not to charge the batteries without first discharging A B menu them as this could cause a reduction in the capacity of the batteries memory effect At any moment you can interrupt discharging recharging by pressing F2 B Interrupt Note 1 if the external power source is cut off during charging charging will be interrupted and resumed from the same point it had reached before being interrupted when the power source has been restored This represents an extra guarantee of the reliability of the recharge system Note 2 during discharging and r
17. of step lengths during a run WalkJump test After selecting the test press F2 Test as indicated on the display to begin the test itself Press F1 Nmod to set the number of modules present on the track ATTENTION for correct functioning of the test it is essential that the number of modules set on Racetime 2 corresponds exactly to the number actually present on the measurement base Select F3 menu to return to the main menu The alignment test checks the measurement base for about 10 seconds during this time the message Please wait is shown This time is normally enough to signal inaccurate alignments which cause intermittent interruptions at some points of the base and which therefore may escape detection by visual control green SIGNAL led on all the modules After data acquisition the points at which an interruption has been detected are displayed Each module includes 32 sensors numbered from 1 to 32 Module 1 and sensor 1 are considered to be those which are near the connection cable between modules TX and modules RX To view the next interrupted sensor press F1 Next Press F4 esc to return to the main menu If on the other hand alignment is perfect a message of confirmation is displayed MICRO Q GATE Racetime 2 OptoJump Program A Aver all values B Keyb beep On C Accu charge A B C menu User manual 8 4 3 Fl Averages all values minimum and maximum excluded
18. re from the ground is taken as the moment of the start From this screen display it is possible to completely eliminate the test performed by pressing F3 Attention it is not possible to annul elimination Press F4 again to return to the previous screen display MICRO Q GATE Racetime 2 OptoJump Program Start extern Length s 10 User manual 14 5 8 F3 Jump test time Select this mode to carry out tests of pre established duration After selecting the test choose the start mode ie the athlete s position at the start of the test with the keys F1 test start from inside the measurement area or F2 test start from outside the measurement area Press F4 OK to confirm your choice Insert the duration of the test in seconds Racetime 2 will then display the athlete s code and the test For performance of the test and the data displayed refer to the previous paragraph Jump test number of jumps During the display of average values at the end of the test the code will be shown as follows JtE Jumptest time external start JteI Jumptest time internal start MICRO Q GATE Racetime 2 OptoJump Program Num of jumps Athlete 1 Test N 1 Start from inside OK Edit Setup menu Step into the base F1 start test Test User manual 15 5 9 F1 Acoustic reaction The acoustic reaction test makes it possible to evaluate the reaction time of an athlete to a randomly generated acou
19. s rhythm and step length are printed Average values for the same measurements are also given Note printing takes place automatically when you pass to the next test if the automatic print mode has been set see chap 4 1 Press F3 values to pass to the screen display of the individual jumps press keys and T to view the next or previous jump respectively F2 clear eliminates the jump displayed Attention it is not possible to annul elimination F1 esc returns you to the display of average values By pressing F4 you enter a second screen display in which you can see the average values for contact time flight time height and rhythm as well as the real duration of the test If two photocells connected to the start line are used to register entering and exiting of the base the actual duration of the test coincides with the time taken to cover the distance of the base From this screen display it is possible to completely eliminate the test performed by pressing F3 Attention it is not possible to annul elimination Press F4 again to return to the previous screen display MICRO Q GATE Racetime 2 OptoJump Program 1 1 1 1 1 1Belt speed 0 Km h User manual 19 5 13 F3 RollJump The RollJump test has been devised so as to make it possible to use the OptoJump system in combination with the mobile running boards tapis roulant used to simulate running in the gymnasium The OptoJump system acquires cont
20. s to modify the test settings see following paragraph MICRO QJ Racetime 2 OptoJump Program Start extern Int Ext Start extern Num Of jumps Athlete 1 Test N 1 Start from inside OK Edit Setup menu User manual 11 To confirm the settings and to go on to the performance of the test press See the following paragraph for an explanation of the values displayed during the test 5 2 F2 Jump test jumps Select this mode to perform tests with a pre established number of jumps After selecting the test select the start mode i e the position of the athlete at the start of the test with the keys F1 test start from inside the measurement area or F2 test start from outside the measurement area Press F4 OK to confirm your choice Insert the number of jumps you wish to make 5 3 Racetime 2 will then show the athlete s code and test Important the combination athlete s code test number is a single item 1 Racetime 2 does not allow the same athlete to perform two tests indicated by the same test number Choose F1 OK to confirm the setting and to begin the test By pressing F2 Edit you can correct the number of the athlete and or test F3 Impos will return you to the setting of the start test mode and of the number of jumps To return to the New tests menu press F4 menu MICRO Q GATE Racetime 2 OptoJump Program JumpN 4 Tc 0205 Tf 0618ms He
21. st can be interrupted before completion by pressing CE It is possible to confirm by pressing F4 OK or to annul the whole test by pressing F3 CleTst Step length is acquired at the end of the test It is important that no one should enter the measurement area after the end of the test before the acquisition of step length has finished Acquisition can last a few seconds especially if many modules are used If the number of steps registered does not coincide with the number of contact and flight times acquired a warning message appears on the display However Racetime 2 memorizes all the information acquired if the number of steps is higher than the number of contact flight sequences the extra steps will be given zero contact and flight times should the opposite be the case number of contact flight sequences higher than steps acquired the length of the extra steps will be zero MICRO Q Racetime 2 OptoJump Program 1T 4Walk Lenm 42 4 cm esc print values gt 5 12 JumpN 1 Tc 0589 Tf 0649ms Hei 51 7cm Rh 48j m esc clear Len 183 4cm 5 13 N 1T 3 Walk Tcm 0469 Tfm0487ms Heim30 4cm Rhm 62j m T 9 570 clear 5 13 User manual 18 5 12 Press F1 esc to go on to the next test The values of the test made obviously remain in the memory for subsequent reprinting Press F2 print to obtain a printout of the values measured for each jump contact time flight time height instantaneou
22. stic signal After selecting this type of test the number of jumps i e subsequent tests to be made must be set Racetime 2 will then show the athlete s code and the test code Important the combination athlete s code test number is a single item that is to say Racetime 2 does not allow the same athlete to perform two tests indicated by the same test number Choose F1 OK to confirm the setting and to begin the test By pressing F2 Edit you can correct the number of the athlete and or test F3 will return you to the setting of the number of tests To return to the New tests menu press F4 menu After confirming with F1 make sure that the athlete is situated inside the measurement area and confirm with F1 it is possible to return to the previous screen display with F4 An initial beep simply signals the start of the test From this moment within a time varying from 2 to 6 seconds a second beep will be emitted Racetime 2 measures the time between this signal and departure from the measurement area Flight time i e the time from departure from the base to the athlete s subsequent return to it is also measured Consequently the test can also be made by getting the athletes under trial to follow a pre established course so measuring the time taken to cover a distance It is clear that in this case the height measured is of no significance The test can be interrupted before completion by pressing CE Attention
23. t base Timeout press F3 to modify the value set time elapsed in seconds the acquisition of which is automatically interrupted If the value 0 zero is set acquisition finishes when an impulse on the starting line is sent or the start key is pressed When F4 other is pressed other settings are displayed namely Minimum step length press to modify the value set specify the minimum step length this value is used during the acquisition of step length data to filter possible false steps resulting from double contacts with the ground heel toe Values below 20cm are not accepted Racetime 2 always approximates the value set to a multiple of 3 1115cm which is the interaxis between two successive data acquisition points Entrance press F2 to modify the value set specify the running direction Int side the athlete runs the distance of the base after entering from the side with the interface for Racetime 2 or PC connection cable side the athlete runs the distance of the base after entering from the side with the connection cable between modules TX and RX Automatic acquisition press F3 to modify the value set select yes if you want the system to automatically set itself to acquisition mode after each passage of an athlete so as to make it possible to register two or more passages completely automatically MICRO Q GATE Racetime 2 OptoJump Program Athlete 1 Test 1 OK Edit Setup
24. ta transmission A B C more MICRO Q GATE Racetime 2 OptoJump Program User manual 24 8 Memory limits Racetime 2 makes possible the storage of data for about 2000 jumps the number varies according to the number of different trials made When its memory limit has been reached at each jump Racetime 2 displays the message memory full Previously memorized data is not canceled to enable the user if he so wishes to transfer information to the Personal Computer chap 4 To cancel the memory Racetime 2 must be switched off and the cancellation of data confirmed chap 3 MICRO Q GATE Racetime 2 OptoJump Program User manual 25 9 Appendix I Racetime 2 transmission protocol for Optojump data are transmitted in ASCII format values 127 7Fh only except the Program code fields are numeric ones padded with 0 Description N of data ASCII Dec Hex Notes Header STX 1 2 02 Start of Text Program code 10 R followed by 8 blanks CR 1 13 0Dh Carrage Return begin loop test Test type 3 02 Jumptest jumps start intern 03 Jumptest jumps start extern 04 Jumptest time start intern 05 Jumptest time start extern 06 Acoustic reaction 08 Walkjump 18 12h Squatjump 34 22h CMJ 50 32h 2 CMJ AF 66 42h Technical test 83 53h Stiffness 99 63h Stiffness AF 116 74h Jump 15s 132 84h Jump 30s 148 94h Jump 60s Athlete s Code 4 lt 9999 starts from 1 N test 3 lt 9
25. your system Press a key to continue At this point the following screen displays may appear Check to see if the device was completely emptied after the previous work session Any previously memorised data has been irretrievably lost Press ENTER to continue Check to see if any anomalies were discovered during initial tests on the machine Contact Microgate for further information Usually appears after switching on Press F3 to delete previously memorized data your choice must be confirmed MICRO Q Racetime 2 OptoJump Program A Single start B Group start C Simple stopwatch C more A B A Parallel mode B PC ON LINE mode C OptoJump A B C menu Clear all config data Yes User manual 4 Should you have canceled the memorized data if your Racetime 2 chronometer is equipped with other timing programs in addition to the Optojump management program you can select the function mode To select the Optojump program first press F4 other to pass to the second screen display Now press F3 C Optojump to enter Optojump mode These operations are not necessary if your Racetime 2 is equipped with only the Optojump program If the data memory has not been canceled or the Optojump mode was chosen in the previous work session you can set configuration parameters automatically on standard values namely e Automatic printout on confirmation of test deactivated Average value