1. V JDSU L3 2 56 screws x 4 Pil 21100 Instruments Page 18 207 LaserMount User s Manual 4 30 109 2 1 di 1 6 32 X 1 4 LONG PHIL FLAT HEAD UNDERCUT MACHINE SCREW 5 40 137 2 4 80 121 9 Y 3 2 70 168 6 m 50 127 LI I 4X 4 40 UNC 2 82 71 6 om 207 with Fiber Tray 2170 0 Instruments 3 35 85 1 2 30 58 4 207 LaserMount User s Manual Page 19 E S rrr 123456 9 Gy 2X 6 32 X 1 0 LONG SHCS J zc ud 30808 EE 3 25 82 5 e Ke 9 e eu 207 with Cover Instruments Page 20 207 LaserMount User s Manual Laser Diode Protection Electrostatic discharge and current spikes can be a significant cause of damage to laser diodes but when proper precautions are taken these risks can be greatly reduced or eliminated Arroyo Instruments controllers offer state of art laser diode protection but no instrument can fully shield the laser from damage Please take these considerations into account when operating your laser 1 Always set the current limit at or below the maximum current your laser can handle This prevent
2. Quick Disconnect Plug The 207 comes with one plug Additional plugs are available from Arroyo Instruments part number 1202 and we also offer pre wired connector assemblies for many common lasers Wired for JDSU L4 Laser Arroyo Instruments offers several different wiring harnesses for many popular lasers from JDSU LaserTel Alfalight Lumics and others Contact Arroyo Instruments for assistance in selecting the appropriate wire harness The quick disconnect plug has screw terminals for each position Simply strip off about of each wire s insulation insert into the appropriate position and tighten the screw 2110 0 Instruments 207 LaserMount User s Manual Page 5 Devices with Internal Temperature Sensors Some lasers include an internal temperature sensor typically a thermistor It is possible to use the device s internal sensor rather than the sensor in the 207 which will typically provide a higher degree of accuracy and stability On the back of the mount there is a SENSOR switch with two positions INT and EXT The INT position selects the thermistor in the 207 while the EXT position selects the sensor wired to the S and S connections of the quick disconnect interface NOTE Earth Grounding Considerations The DB 9 and DB 15 connectors are electrically connected to the housing and 8mm banana jack Depending on the wiring of your cables and instruments this may or may not p
3. H 2 59 65 8 207 Top and Rear Views Pr 21100 Instruments Page 16 207 LaserMount User s Manual Sus Gas Quo S Kou INSS XX T p d BE 9X 2 56 UNC 7 N ES pal 701178 1 5113 3218 2 1 23 5 7 E 1 20151 15 3 8 03 0 6 001 m 5 i 15 3 8 1 20 5 321821 P 39 9 9 E 51 13 6X 4 40 UNC x 7 70 17 8 N 4X 4 40 UNC N iu oa iq O SS SARE DETAIL A Detail View of Mounting Hole Pattern 2170 0 Instruments 207 LaserMount User s Manual Page 17 Mounting Locations for Standard Plate d e O O ff e Butterfly SP package Alfalight AM6 package 2 56 screws x 4 0 80 screws x 4 2 56 screws x 4 n o o O O e O A I I Lumics TO package STAR LED JDSU L4 4900 2 56 screws x 1 4 40 screws x 6 2 56 screws x 2
4. Mounting your device The cold plate often supports multiple laser hole patterns so first locate the holes appropriate for your laser Thread sizes will typically be 0 80 2 56 or 4 40 and screws included with your mount but if in doubt consult the mechanical drawing for the cold plate or contact Arroyo Instruments Using improper screws can permanently damage the threads When you screw in the mounting screws do not over tighten as you can strip the threads in the mounting plate Device Loaded Pr 2110 0 Instruments Page 8 207 LaserMount User s Manual Connector Pin Outs 207 LaserMount Connectors Description 1 PDC Photodiode cathode 2 PDA Photodiode anode 3 LDC Laser cathode 4 LDA Laser anode 5 5 Temperature sensor positive 6 S Temperature sensor negative Quick Disconnect Pin Out DB 9 Pin Description 1 3 No connection 4 amp 5 Laser cathode 6 Photodiode cathode 7 Photodiode anode 8 amp 9 Laser anode Laser DB 9 Connector Pin Out DB 15 Pin Description 1 2 9 TE 3 4 10 TE 7 Thermistor 8 Thermistor 11 Fan 12 Fan 5 6 13 15 No connection TEC DB 15 Connector Pin Out 2 0 0 Instruments 207 LaserMount User s Manual Page 9 Fan Power Connection The fan base can be powered either through a 2 1mm round DC jack center positive located on the rear of the fan base or via pins 11 amp 12 on the TEC DB 15 connector see above Using
5. 0 Instruments Page 6 207 LaserMount User s Manual Mount with Fiber Tray Installed Using the Optional Cover For applications that demand the best in thermal stability a cover is available for the 207 that insulates both the device and cold plate from air currents that can otherwise cause instability Two alignment pins locate the cover on the mount and prevent it from sliding around when the screws are not installed For more permanent installations two socket head screws are provided that can bolt the cover to the mount to prevent removal and also add additional protection for the device The cover can be used in conjunction with the fiber tray Mount with Cover and Fiber Tray Installed Pl ar 0yo Instruments 207 LaserMount User s Manual Page 7 Connecting to the Laser Diode Driver and TEC Controller Next connect the 207 to your laser diode driver and temperature controller NOTE Arroyo Instruments offers Laser and TEC cables designed to connect directly between our LaserSource and TECSource products If you use your own cables ensure the connections are properly made between the instrument and the mount and that proper grounding techniques are used The pin out of the connectors can be found later in this document Be sure you are properly ESD protected before handling your laser For additional information read the section titled Laser Diode Protection later in this manual
6. As an example assume your lab is at 20 C and you will be operating the mount at 25 C then the operating point is 5 C above the ambient temperature and the thermal capacity would be 14W the 5 C point on the x axis 207 Thermal Capacity 25 C Ambient 20 10 0 10 20 30 40 50 60 T from Ambient C The graph assumes the fan is operational The capacity of the mount without the fan will be significantly less Also when ambient temperature is significantly away from 25 C the actual capacity will be slightly different Pl Instruments Page 12 207 LaserMount User s Manual Using the Thermistor on Standard Versions The standard version of the 207 LaserMount is equipped with a 10kQ negative temperature coefficient NTC thermistor specifically the BetaTHERM 10 1 A thermistor works by translating temperature into resistance with resistance decreasing as temperature increases hence the negative coefficient Below is the response curve of the thermistor 50000 40000 30000 20000 Resistance Q 10000 0 10 00 10 00 30 00 50 00 170 00 90 00 110 00 Temperature C Resistance vs Temperature Graph As can be seen be the graph the resistance of the thermistor drops very quickly In the typical control range 0 C to 40 C typical 10K thermistors offer good sensitivity to changes in temperature and this is the
7. increases RTDs are also a fairly linear device meaning they can be used across a much broader temperature control range As per IEC751 the resistance temperature relationship is determined using one of two equations dependent on the temperature or resistance value being measured For resistances above the R value resistance at 0 C typically 1000 as is the case with the RTD used in the 207 150 of the RTD the following equation is used R R 1 AT Below Rg an additional term is added to the equation R R 1 AT BT C T 100 77 In both of these equations R is the resistance of the RTD at 0 C and A B and C are the coefficients as defined by IEC751 through regression analysis or by using the Callendar van Dusen method Pl 0 Instruments Page 14 207 LaserMount User s Manual For the Arroyo Instruments controllers that support RTD sensors the default coefficients are different for this mount They must be changed to use the 0 00385 curve which has the following coefficients A 3 9080x10 B 0 58019 10 4 2735 1012 100 These coefficients can be changed the Sensor menu 2 Wire versus 4 Wire Measurements One concern in using RTDs are their relatively low resistance typically 1000 at 0 C and small Because of these two factors the resistance of the cable used to connect to the sensor can create significant absolute error in the sensor measure
8. range in which most 10K thermistors are typically used 10K thermistors can be used at much higher temperatures but will suffer poorer temperature stability performance because of the lower sensitivity All Arroyo temperature controllers support operation using a 10 or 100 thermistor bias which limits the upper control range to 450 or 45 respectively To minimize noise and maximize stability you should select highest current while still allowing you full operation across your required temperature range The typical setting is 100pA but your application will determine the actual needs Pl arroyo Instruments 207 LaserMount User s Manual Page 13 The Steinhart Hart Equation As can be seen from the temperature versus resistance graph above resistance varies inversely with temperature in a non linear fashion This relationship can be accurately modeled by polynomial equations and one such being the Steinhart Hart equation L A B In R N R The coefficients for the BetaTHERM 10K3A1 thermistor are A 1 12924x10 2 34108 10 0 87755 107 These are the default coefficients for Arroyo Instruments temperature controllers Using the RTD on 150 C Versions 207 150 LaserMount is equipped with RTD sensor with 0 00385 Q C sensitivity Like thermistors RTDs also function by converting temperature into resistance but unlike thermistors RTDs increase in resistance as temperature
9. USER S MANUAL TEC MOUNT J arroyo instruments Page 2 207 LaserMount User s Manual Table of Contents ntgorolVreio 3 Installation and USC 4 Connector Pin Outs cnet rit edt ee denne cxt 8 Technical Specifications eene 10 Thermal 11 Using the Thermistor on Standard Versions 12 Using the RTD on 150 C 13 Mechanical 15 Laser Diode Protection ecce e rege 20 21 Service and 21 Pl at 0yo Instruments 207 LaserMount User s Manual Page Introduction Thank you for choosing the 207 LaserMount from Arroyo Instruments The LaserMount is designed for high performance and long term use with innovative features not found in other mounts With the integrated fan selectable thermistor input and quick disconnect interface the 207 is an excellent choice for medium power laser and LED applications The 207 is a smaller version of the more powerful 264 LaserMount With 12W of thermal capacity the 207 works well with many fiber pigtailed lasers operating in the 5W to 10W optical power range The standard cold plate accepts lasers from several different manufacturers including JDSU Al
10. falight Lumics and others and custom mounting options are available The 207 also works with 200 TRAY fiber management tray and 200 C cover The fiber management tray provides an elegant solution for managing excess fiber without the use of clips or ties while the cover improves the thermal stability of the system by insulating the device and cold plate from air drafts Connecting your device is easy through the use of a pluggable interface allowing you to permanently connect the laser and TEC cables to the mount and use a simple quick disconnect fitting to make the connection to the device The LaserMount also offers all the features you would expect from a modern laser diode fixture including e Designed to be quickly integrated with Arroyo s LaserSource and TECSource instruments e Industry standard D sub connectors and pin outs allow for quick integration into existing laser applications e Optional fiber management tray p n 200 TRAY for managing excess fiber pigtail s e Optional cover p n 200 COVER when improves the temperature stability of the system e Additional quick disconnect plugs p n 1202 Pr 21100 Instruments Page 4 207 LaserMount User s Manual Installation and Use Wiring the connector to your device The 207 uses a removable connector to make the connection between your device and the mount Depending on the type of connections you have for your device you many use some or all of the terminals
11. graph Size H x W x D in mm 2 44 62 x 3 50 89 x 5 00 127 Weight Ibs kg 1 6 0 7 Fixture Mounting Holes 14 20 through hole 3 on center x2 Device Mounting Screws 0 80 x 1 8 stainless steel socket head x4 2 56 x 1 8 stainless steel socket head x4 4 40 x 1 8 stainless steel socket head x6 1 At 25 ambient fan running at 12VDC 2110 0 Instruments 207 LaserMount User s Manual Page 11 Thermal capacity is the ability of the mount to remove a given amount of heat When considering thermal capacity both the operating and ambient temperatures must be considered Higher ambient temperatures lower the thermal capacity of the mount as does lower operating temperatures Often a device may work fine at 25 C but not be able to reach 15 C or 20 C because of the amount of heat given off by the device In many applications the absolute temperature is not critical so when using devices with high thermal loads you may need to operate the device towards the upper end of the operating temperature range Make sure to consult the specifications to ensure you do not exceed the temperature range of the device To determine the thermal capacity determine how far above positive or below negative the ambient temperature you will be operating then consult the graph below which shows the capacity of the mount in terms of C away from the ambient temperature at a nominal 25 C ambient
12. ment Most Arroyo Instruments controllers offer two RTD measurement modes a conventional two wire measurement mode which is subject to this error and a four wire measurement mode that uses separate sense and source lines to remotely sense the actual resistance of the RTD and eliminate the cable and connector resistances In the 207 150 LaserMount the 4 wire connection is made inside the mount To use this measurement mode you must select RTD 4 wire as the sensor type The drawings below illustrate how 2 wire and 4 wire connections work Note that 4 wire measurements require all four wires to be brought through the cable to the mount The 1262 TECSource cables carry these connections through to the mount but the 1260B cable does not 4 Temperature Sensor Controller Sensor Temperature Controller RTD 4 wire Measurement 2110 0 Instruments 207 LaserMount User s Manual Page 15 Mechanical Specifications 1 50 38 1 1 1 10 27 9 Y 1 2 30 584 DEVICE PLATE C 2 40 61 5 00 127 2X 9 276 8 Y 4X 6 32 UNC ee Loser Mount TEC Loser TEC LaserMount 3007621 350 88907 4131321 4 7 59115 i da N ez CENE 2 441621 1 95 495 9 181 b ez 92 Y i931 1 1 07 27 3 H 2 19 55 6
13. rkmanship under normal use and service for a period of one 1 year from date of shipment It does not apply when the product has been misused altered or damaged by accident or abnormal conditions of operation If found to be defective during the warranty period the product will either be repaired or replaced at Arroyo Instruments s option THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARROYO INSTRUMENTS SHALL NOT BE LIABLE FOR ANY INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS Service Support For service and support contact your local distributor or Arroyo Instruments By mail Arroyo Instruments 624 Clarion Court San Luis Obispo CA 93401 USA By phone 1 805 543 1302 By fax 1 805 543 1303 By email support arroyoinstruments com On the web http www arroyoinstruments com Pr 21100 Instruments Page 22 207 LaserMount User s Manual NOTES 2110 0 Instruments 207 LaserMount User s Manual Page 23 NOTES Pl 21100 Instruments arroyo Instruments 624 Clarion Court San Luis Obispo CA 93401 Tel 805 543 1302 Fax 805 543 1303 sales arroyoinstruments com www arroyoinstruments com Copyright 2012 Arroyo Instruments All Rights Reserved 530 1021 Rev C
14. rovide earth grounding of the fixture Make sure the cable shell is earth grounded on both ends of the cable and that the instrument makes connection from its connector to earth ground If in doubt you can also use a grounding strap from the 8mm banana jack directly to earth ground Powering the Fan If you will be using the 5300 Series TECSource temperature controller to power the fan make sure to use 1260B or 1262 cable which has the additional connections for the fan power supply Otherwise you can use a 12V DC external power supply with a 2 1mm round DC power jack center positive It is possible to operate the fan as low as 6 5V if you would like to reduce the fan noise or vibration but low fan speeds will reduce the thermal capacity of the mount For lower power lasers the fan may not even be required Using the Optional Fiber Management Tray The 207 supports an optional fiber management tray p n 200 TRAY which makes managing excess fiber much simpler by providing a protected area to coil the fiber Unlike other solutions that use ties to retain the fiber our fiber tray has an upper lip that catches the fiber retaining it gently without needing any ties To install the tray simply use the provided screws Note that if you will be using the cover and screwing it down you will need to install only the front two screws as the socket head screws that come with the cover will use the rear two threaded holes Pri
15. s the device from accidentally driving the current too high either via the set point or from the modulation port This also provides additional current limiting protection from ESD 2 Always work in an ESD safe operating environment including the use of wrist straps ESD grounded work surfaces and floors and ESD safe tools 3 Where the AC power to the laser driver to temperature controller may be noisy use isolation transformers or uninterruptible power supplies that provide isolation 4 Make sure all cables are securely connected and fastening screws are screwed in tight 5 Do route power cords or other cables in parallel with the laser or temperature controller cables as coupling may occur between the cables and inject noise into the laser diode 6 While it is not possible to create a ground loop through the LaserSource because of it s isolation of all inputs it is possible when using other equipment Ensure that any other equipment is properly isolated to avoid any ground loop problems For additional ESD protection adding 3 5uH Mouser P N 542 FB73 287 ferrite beads as close to the laser diode as possible is recommended One ferrite bead should be used on each laser diode and photodiode diode anode and cathode with the wire going through the bead at least twice two turns Pl at 0yo Instruments 207 LaserMount User s Manual Page 21 Arroyo Instruments warrants this product to be free from defects in material and wo
16. the DC jack will disconnect the TEC DB 15 power connection preventing simultaneous connection of two power supplies to the fan SENSOR Switch The SENSOR switch is used to select which sensor input will be connected to the TEC DB 15 connector Selecting the INT position will connect the 207 s built in thermistor while selecting the EXT position will connect the S S terminals on the quick disconnect plug Instruments Page 10 207 LaserMount User s Manual Technical Specifications 207 TEC LaserMount LASER PACKAGE SUPPORTED Packages Standard plate support JDSU L3 amp L4 Alfalight AM6 various Lumics STAR LEDs standard butterfly Q Photonics SP Sheaumann SP 940 IPG iPLD 9 others Custom mounting available TEMPERATURE CONTROL Standard Version Temperature Range C 15 to 85 Sensor Type BetaTHERM 10K3A1IA Sensitivity 10kQ 25 C TE Module at 25 C 5 6 8 2V Recommended Controller 5240 TECSource or 485 04 08 TECPak High Temperature Version Temperature Range C 15 to 150 Sensor Type Platinum RTD Sensitivity 1000 9 0 C 0 00385 0 0 TE Module at 25 C 2 5A 14V Max Recommended Controller 5300 2 5 24 TECSource 2 5A 24V INPUT CONNECTOR Laser DB 9 male TEC DB 15 male DEVICE CONNECTOR Maximum Current 10A Part Number Arroyo Instruments p n 1202 Phoenix Contact p n 1778027 FAN POWER Connector 2 1mm round center positive Voltage Current 12V DC 150mA Thermal Capacity 12W at 25 C see