Home
Owner`s Manual - Sears PartsDirect
Contents
1. t off run after 3 minutes delay run i Run for about 1 minute without other When opening power actions Mist is blown from air B The high humidity air in room is i When cooling l conditioner cooled rapidly Slight click sound heard once begin Sound of initialization for electric running expand valve Hissing sound heard continuously The sound for gas refrigerant flowing when cooling in the unit P Hissing sound heard when staring or The sound for gas refrigerant stops Noise is heard from air a stopping flow conditioner Slight hissing sound heard when i l Sound for running of drainage system running or after running i The grating sound caused by expands Creak sound heard when running or f i of panel and other parts for the after running change of temperature Dust be blown for air Started up after long time s doesn t oe a Dust in indoor unit be blown out conditioner runs This is because when air conditioning Odor gives out from air odors or cigarette smoke from the E When running o conditioner room that was sucked in is discharged again w After sales Service When having quality or other problems when purchasing air conditioner please contact the local service center 3 Maintenance Method Maintenance Method When air conditioner won t be used for a long time please cut off the main power supply of air conditioner ZA Warning Do turn off the unit and cut off th
2. Follow all safety codes Wear safety glasses and work gloves Keep quenching cloth and fire extinguisher nearby when brazing Use care in handling rigging and setting bulky equipment Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit Consult local building codes and National Electrical Code NEC for special requirements Recognize safety information This is the safety alert symbol A When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation A WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death Before installing modifying or servicing system main electrical disconnect switch must be in the OFF position There may be more than 1 disconnect switch Lock out and tag switch with a suitable warning label A WARNING EXPLOSION HAZARD Failure to foll
3. Electrical Code for special requirements All wires must be sized per NEC or CEC and local codes Use Electrical Data table MCA minimum circuit amps and MOCP maximum over current protection to correctly size the wires and the disconnect fuse or breakers respectively Per caution note only copper conductors with a minimum 300 volt rating and 2 64 inch thick insulation must be used Communication Wiring A separate shielded copper conductor only with a minimum 300 volt rating and 2 64 inch thick insulation must be used as the communication wire from the outdoor unit to the indoor unit To minimize voltage drop of the control wire use the following wire size and maximum lengths shown in the chart below Length Wire Size ft m 18 AWG 50 15 16 AWG 50 15 to 100 30 a CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation e Wires should be sized based on NEC and local codes e Use copper conductors only with a minimum 300 volt rating and 2 64 inch thick insulation User Notice When operating the entire capacity of the cooperating indoor unit should be not larger than 150 of outdoor unit Otherwise it will cause the shortage of cooling heating capacity A Breaker or fuse need to be installed in every indoor unit and the capacity should in according with indoor unit s electrical parameter all the indoor units are r
4. if the operation is incorrect Note This mark means that it may cause casualty or property loss if the operation 15 incorrect Warning Do not adopt fuse with unsuitable capacity or adopt iron thread instead of fuse otherwise malfunction or fire may happened Cut down the main power switch immediately if malfunction such as smell the burning odor etc happened Maintain ventilation to prevent oxygen leakage in room Don t insert finger or stick like things into discharge vent or outlet grill Please make sure that the unit is installed in the place that can bear the weight of it adequately If the place is not strong enough the air conditioner may drop and cause casualty event Don t spray or smear any oil paint or insecticide on the surface of unit otherwise fire may be leaded Do not refit the conditioner Please contact the agency or prefect ional personnel to repair or move the conditioner An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring A Note Please check and make sure that the cord drainage pipe and tubes are connected in the correct way to prevent leakage of water refrigerant electric shock or fire The main power must connectable to the earth in order to assure the conditioner earthing effectively and to prevent electric shock Please don t connect the earthing line with the gas pipe water pipe lighte
5. to repair or move the conditioner w Check the following items before contacting maintenance center Phenomena Reason Remedial Measures Blow of fuse or breaker Change fuse or close breaker Power cut Air conditioner doesn t Don t connect with power Connect power well run at all Low batteries of wireless remote Change new batteries controller Wireless remote controller exceed l a Signal could be recetved within 8m remote control area Air conditioner runs but Blockage in inlet or outlet vent of Clean out blockage stops immediately indoor or outdoor unit Blockage in inlet or outlet vent of Clean out blockage indoor or outdoor unit i Adjust settings in wireless remote Improper of temp setting controller E Adjust settings in wireless remote Low setting of fan speed controller o COS Adjust settings in wireless remote Incorrect of wind direction controller Abnormal cooling or l Door or window opened heating Hang curtain or jalousie before Direct sun burn windows Too many people in room Too many heater in room Filter blocked by dirt Clean filter 12 Malfunction Debarring Instruction If problem still cannot found out after above checking please contact service center and instruct phenomena and model The following circumstance are not malfunction Malfunction Reason Start up unit immediately after turned The overload protects switch makes it Air conditioner doesn
6. 40GJ C Cassette Ductless Split System Sizes 12 to 24 E aner turn to the experts NJ Owner s Manual the environmental ty sound refrigerant NOTE Read the entire instruction manual before starting the installation NOTE TO EQUIPMENT OWNER Please read this Owner s Information Manual carefully before installing and using this appliance and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION DEALERSHIP CONTACT INFORMATION Model Company Name Serial Address INSTALLATION INFORMATION Date Installed Phone Number Technician Name SAFETY CONSIDERATIONS Installing starting up and servicing air conditioning equipment can be hazardous due to system pressures electrical components and equipment location roofs elevated structures etc Only trained qualified installers and service mechanics should install start up and service this equipment Untrained personnel can perform basic maintenance functions such as cleaning coils All other operations should be performed by trained service personnel When working on the equipment observe precautions in the literature and on tags stickers and labels attached to the equipment
7. Type Indoor Unit Drainage equipment inside type Discharge condensate water from indoor unit when cooling ee Drainage hose Guide louver placed in air outlet vent Air outlet vent gt gt Connecting pipe Air filter purifier in L air inlet grille Arr inlet grille 40GJQBI12C 3 40GJQB18C 3 40GJQB24C 3 10 Working Temperature Range Working Temperature Range Working Temperature Range Dry bulb Wet bulb Dry bulb Wet bulb temp temp temp temp Rated Cooling 80 6 F 27 C 66 2 F 19 C 95 F 35 C 75 2 FQ4C 89 6 F 32 C 73 4 F 23 C 118 4 F 48 C 78 8 F 26 C 69 8 F 21 C 59 F 15 C 64 4 F 18 C 68 F 20 C 59 F 15 C 44 6 F 7 C 42 8 F 6 C 80 6 F 27 C BFO 64 4 F 18 C 59 F 15 C 5 F 15 C 3 2 F 16 C Malfunction Debarring Malfunction Debarring A warnings Cut down the main power switch immediately if malfunction such as smell the burning odor etc happened and then contact service center If the abnormal state 15 maintained the unit may be damaged or electric shock or fire may be happened Do not refit the conditioner Please contact service center
8. ace where easy drain condensated coagulated water and easy connect with outdoor unit 6 Make sure that there are enough space for care and maintenance Make sure that the weight between the indoor unit and ground is above 70 6 7 in 1800 mm 7 When installing the steeve bolt check if the install place can stand the weight 4 times of the unit s If not reinforce before installation Refer to the install cardboard and fi d where should be reinforced A Note There will be lots of lampblack and dust stick on the acentric heat exchanger and water pump in dining room and kitchen which would reduce the capacity of heat exchanger lead water leakage and abnormal operation of the water pump The following treatment should be taken under this circumstance l Ensure that the smoke trap above cooker has enough capacity to obviate lampblack to prevent the indraft of the lampblack by the air conditioner 2 Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner Important notice To guarantee the good performance the unit must be installed by professional personnel according with this instruction 25 3 5 in 650 mm ee ae ed 22 4 9 in 570 mm 15 3 4 in 400 mm Refrigerant pipe 35 in 890 mm Ceiling opening 780 mm Gaps between hoisting screw rods Hoisting screw X4 30 5 7 in 37 2 5 in 950 mm Decorated surface board
9. al drain hoses join together Abovel00mm T tie in join drain hose The specs of the selected join drain hose should fits the running capacity of the unit Fig 10 2 Check the smoothness of drain after installation Check the drain state by immitting 36 3 5 in 600 cc water slowly from the outlet vent or test hole Check the drain in the state of refrigerating after installation of the electric circuit 6 Install of The Compact Panel Cassette Type Indoor Unit Way of immiting Drain hose T i est hole cover Drain vent for repair use plastic I ea stopper is included drain the water Test hole in waterspout by this outlet vent lt Immiting water from the rest hole gt Plastic water pot The length of the pipe should be about 4 in 100 mm lt Immiting water from the outlet vent terminal gt Fig 1 Electrical wiring A Note The power of the entire indoor unit must be connected in outdoor unit About the electrical wiring please see the circuit diagram attached with the unit All the installation of electrical wiring must be done by professional personnel Please do take the earthing treatment Wiring method of connection unit and controller Connection wiring communication Open electric box cover drag the wiring communication from the rubber plug A and impact them well individually by impact fastener 2 Wiring according to the indoor sid
10. ct separation of at least 3mm in all poles should be connected in fixed wiring Information regarding transport storage temperature 13 131 F 25 55 C is missing Main switch provided by end user main switch handle should be black or gray it can be locked in OFF position with padlock The main disconnection device should be explained in user manual and the height should be recommended at 0 6 1 7m over current protection is required UL 1995 CSA C22 2 The cooling range of the unit is the outdoor environment temp 23 118 4 F 5 48 C DB the heating range of the unit only for the heat pump type unit is the outdoor environment temp 5 80 6 FCI 5 27 C WB This product must not be disposed together with the domestic waste This product has to be disposed at an authorized place for recycling of electrical and electronic appliances Contents Sry OTa O l Instali of The Compact Panel Cassette Type dodoor UM 2 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 10 WOtk Hie Temiperatire a i ANNE 1 pa 12 Ma mtenante MeO a 14 Safety Information Safety Information Please read this manual carefully before use this unit and operate it correctly according to the guide in this manual Please take specially note to the meaning of these two marks A Warning This mark means that it may cause casualty or badly heart
11. e circuit diagram Fix the impact fastener after connection Entwine the small sponge on the electric wire do entwine it to prevent condensation Impact tightly by impact fastener after connection and then fit on the electric box Connect the 3 cord rubber wire to the counter terminal of the 3 way terminal board The power cord reference Power cord standard recommending table power supply 3 way terminal board h _ 4 16 rubber wire p To outdoor unit Impact fastener Fig 12 Power cord standard recommending table Power supply Min Sectional Area Min Sectional Area Model V Ph Hz of Earth Wire AWG of Power Cord AWG 40GIQB12C 3 208 203V 1Ph 60Hz UL1015 AWG 18 1 UL1015 AWG 183 3 40GJQOBL8C 208 203V 1Ph 60Hz UL1015 AWG 18 1 UL1015 AWG 183 40GIQB24C 3 208 203V 1Ph 60Hz UL1015 AWG 18 1 UL1015 AWG 183 Install of The Compact Panel Cassette Type Indoor Unit Install the panel 1 Set the panel to the indoor unit body by matching the position of the swing flap motor of the panel to the piping position of the panel to the piping position of the indoor unit as shown by fig 13 2 Install the panel Install the panel on the indoor unit temporarily When install hang the latch on the hook that is located on the opposite side of the swing flap on the panel of the indoor unit 2 positions 2 Hang the remaining 2 latches to the hooks on the sides of the indoor unit Be careful not to let the swing
12. e main power supply when cleaning the air conditioner otherwise electric shock or harm may happen It is forbidden to wash air conditioner by water rinsing otherwise electric shock may happen Cleaning air filter Air filters should be cleaned by professionals with proper operation to ensure personal safety When the usage environment has lots of dust air filter should be cleaned more frequently about once 6 months 1 Open air inlet grille Loosen two screws on the air inlet grille with a screwdriver And pull the 2 handle on air inlet grille at the same time with the direction showed by arrow in fig 17 pull down slowly Reverse when closing 2 Disassembly air filter As shown in fig 18 pull the handle behind air inlet grille raise it and disassembly Then discharge the 3 purifier fixed on filter VAG ane Socom aT onan aan Ne SOT _ _ eT fr rnc rf f PA MY ema ra Z X SLS RG ere aad 3 Clean Adopts cleaner or water to wash filter if the filter is too dirty like oil stain on it adopts warm water lower than 1 1 3 F 45 C with neutral scourer to clean it then dry it in the shade AN note Do not clean the filter by hot water whose temp is higher than 1 13 F 45 C to prevent fade or deformation Do not burn it on fire or the filter would catches fire or deformation 4 Install ai
13. e with the 4th step of Clean Air Filter Stand for purifier Fix bolt of purifier I5 Maintenance Method Function and usage period for air purifying Could adsorb CO CO benzene aldehydes and odor of gasoline ete Could adsorb deleterious material that is smaller than lum in air as dust pollen bacteria and virus Usage period is 6 months to year If it is necessary to be changed purchase new purifier in the nearest Gree special engaged maintenance center Clean Outlet vent and Surface Panel Clean the surface panel by soft dry cloth or wet cloth with neutral scourer It is forbidden to clean surface panel by gasoline benzene diluents cleansing powder ete Ifthe guide louver is too dirty it may be removed to be cleaned As narrated below Disassembly and install of guide louver 1 Disassembly guide louver Screw bolts in both end of guide louver to loose A note Do not wipe guide louver powerfully when cleaning otherwise fluff on surface would fall off 2 Install guide louver Rotate guide louver slightly could install the protruding edge of both end into grooves on both end of guide louver and then tighten bolts x Maintenance before or after usage season Check before the usage season Check if there is blockage in inlet or outlet vent of air conditioner Check if the earthing wire had earthed reliably Check if the air fil
14. equired to be centralized controlled by a total Switch this Switch can cut off the electric power supply in case of emergency The Breaker or fuse on each indoor units have the function of short circuit prevention and abnormal overload avoiding it should be connected in normal situation The total switch controlling the power supply of all the indoor units Before clearing and maintenance job being carried out to the indoor units it is very important to turn off the total power supply switch In order to turn on the units successfully the main power switch should be opened 8 hours before the operation After receiving the turn off signal every indoor unit will continue to work for 20 70sec to make use of the rest cool air or the rest heat air in the heat exchanger while preparing for the next operation And this 15 normal When the selected operating mode of the indoor unit are clash with the operating mode of the outdoor unit the malfunction light will blink after Ss on the indoor unit or remote controller showing that the operation clash then the indoor unit will stop At this time change the operation mode of the indoor unit to the one that would not clash with the outdoor operating mode to make the operation normal The cooling mode is not clash with the dry mode while the fan mode is not clash with any mode The appliance shall not be installed in the laundry An all pole disconnection switch having a conta
15. in raising pipe should be added To prevent bent of the drain hose the distance between hoisting stand should is 3 28 to 4 92 ft 1 to 1 5 m 3 28 to 4 92 ft 1 to 1 5 m Correct 1 100 or more gradient Fig 6 Use the drain hose and clamp attached Insert the drain hose to the drain vent and then tighten the clamp x wrong Entwine the big sponge on the clamp of drain hose to insulate heat Heat insulation should be done to indoor drain hose Install of The Compact Panel Cassette Type Indoor Unit Sponge attachment N N Sponge gray Drain hose Fig 7 Drain stepup pipe note The install height of the drain raising pipe should less than 11 in 280 mm The drain raising pipe should form a right angle with the unit and distance to unit should not beyond 300mm LIL ULL ERLA E Mints led Within 11 4 5 in 300 mm _ Hoisting stand Drain hose attachment saga below in 280 mm z 5 a cP S Fa caer FF en 2 ae z Ceiling Clamp attachment F Fig 8 Instruction The slant gradient of the attached drain hose should be within 3 in 75 mm so that the drain hole doesn t has to endure the unnecessary outside force rim oor z Drain hose attachment z Ee lt gt a lt E a A z oS 1 3 wD Fig 9 Please install the drain hose according to the following process if sever
16. let vent by bolt 3 Adjust the unit to the suitable install place Refer to the fig 3 4 Check if the unit is horizontal Inner drainage pump and bobber switch are included in the indoor unit check if 4 angle of every unit are horizontal by water lever If the unit is slant toward the opposite of the coagulate water flow there may be malfunction of the bobber switch and lead water drop 5 Backout the gasket anchor board used to prevent gasket break off and tighten the nut on it 6 Backout the install cardboard Nut supplied at scene Gasket attachment iat stand Tighten double nuts attachment Fix the hoisting stand firmly Fix the gasket firmly Center of the ceiling iy ere a opening Install cardboard 5 vam 4 Sy J Water lever eg Ne ttn fe Bc ada hac Polyethylene pipe Bolt attachment _ Bolt attachmenb Fix the install cardboard Fig 4 A Note Please do tighten the nuts and bolts to prevent air conditioner break off Connection of the refrigerant pipe When connect the pipe to the unit or backout it from the unit please do use both spanner and torque wrench as shown in fig 5 When connect smear both inside and outside of the flare nut with freeze motor oil screw it by hand and then tighten it with spanner Refer to form to check if the wrench had been tightened too tight would mangle the nut and lead leakage Examine the connection pipe t
17. motor lead wire get caught in the sealing material 3 Screw the 4 hexagon head screws under the latches in about 3 5 in 15 mm The panel would rise 4 Adjust the panel by turning it toward the direction pointed by the arrow as shown in fig 13 so that the adjust board connect the ceiling well 5 Tighten the screws until the thickness of the sealing material between panel and indoor unit reduced to 5 S8mim Swing flap motor Indoor unit Ceiling Es Notes 1 Improper screwing of the screws may cause the troubles shown in fig 14 E ANE aA ee A Water condensatation water drop Fig 14 Install of The Compact Panel Cassette Type Indoor 0 2 If gap still exist between ceiling and decoration panel after tightening the screws readjust the height of the indoor unit As shown in fig 15 If the raising lever and drain hose are not affect can adjust the height of 7 indoor unit by the hole on the corner earner be of p anel H a a te oe pe Ne ee ap Fig 15 X After fixing be sure no gap left between the ceiling and the panel 3 Wiring of the decoration panel Fig 16 Connect the joints for swing flap motor lead wire at 2 places installed on the panel Fig 16 9 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit Constitutes and Names of Parts of Compact Panel Cassette
18. ning rod or the connecting line of telephone The air conditioner should be turned off at least after 5 mins operation otherwise it would affect the duration of the unit Don t let the children operate the air conditioner Please don t operate the unit by wet hand Please turn off the main power of the unit before cleaning the conditioner or change the filter Please cut off the main power if the conditioner will be used for a long time Install of The Compact Panel Cassette Type Indoor Unit Install of The Compact Panel Cassette Type Indoor Unit Schematic diagram of installation spaces Wall surface 5 in 20 mm 4 5 Wall Wall sur face aw H 5 9 T sur face a A 5 00 m m eee eet ate 59 in 70 6 7 in 1800 mm o 4060081203 o 14n unit in mm 40GJOB1I8C 3 an eat 4060594054 Fig l Select install location of the indoor unit 1 Obstruct should put away from the intake or outlet vent of the indoor unit so that the airflow can be blown though all the room 2 Make sure that the installation had accord with the requirement of the schematic diagram of installation spaces 3 Select the place where can stand 4 times of the weight of the indoor unit and would not increase the operating noise and oscillate 4 The horizontally of the installation place should be guaranteed 5 Select the pl
19. o see if it had gas leakage then take the treatment of heat insulation as shown in the fig S Only use median sponge to entwine the wiring interface of the gas pipe and heat preservation sheath of the gas collection tube Install of The Compact Panel Cassette Type Indoor Unit Smear freeze motoroil here Median sponge attachment en ect tases i entwine the wiring interface with seal mat N gt Heat preservation sheath of liquid inlet tube attachment for liquid tube Heat preservation sheath of gas collection Gas collection tube tube attachment for ee zas tube Liquid inlet tube 8 Fig 5 Form 1 Fhe tightening torque needed for tightening nut Wiring interface Flare nut Diameter Inch Surface thickness Cin mm Tightening torque 1 4 20 02 in 0 5 mm 20 34 40 68 0615 30 N m 20 03 in 0 71 mm 40 68 54 24 1000 40 N m 1 2 0 04 in 1 mm 61 02 67 8 ft 1b 45 50 N m 95 8 20 04 in 1 mm 81 36 88 14 ft 1b 60 65 N m 0 04 in 1 mm 94 93 101 7 ft 1b 70 75 N m Drainage hose l Install the drain hose The diameter of the drain hose should be equal or bigger than the connection pipe s The diameter of polythene pipe Outer diameter 1 in 25 mm Surface thickness 20 06 in 1 5 mm Drain hose should be short and drooping gradient should at less 1 100 to prevent the formation of air bubble If drain hose cannot has enough drooping gradient dra
20. ow this warning could result in death serious personal injury and or property damage Never use air or gases containing oxygen for leak testing or operating refrigerant compressors Pressurized mixtures of air or gases containing oxygen can lead to an explosion A CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Do not bury more than 36 in 914 mm of refrigerant pipe in the ground If any section of pipe is buried there must be a 6 in 152 mm vertical rise to the valve connections on the outdoor units If more than the recommended length is buried refrigerant may migrate to the cooler buried section during extended periods of system shutdown This causes refrigerant slugging and could possibly damage the compressor at start up SYSTEM REQUIREMENTS Allow sufficient space for airflow and servicing unit See Fig 1 for minimum required distances between unit and walls or ceilings Recommended Connection Method for Power and Communi cation Wiring To minimize communication wiring interfer Power Wiring The main power is supplied to the outdoor unit The field supplied connecting cable from the outdoor unit to indoor unit consists of three 3 wires and provides the power for the indoor unit Two wires are high voltage AC power and one is a ground wire Consult your local building codes and the NEC National Electrical Code or CEC Canadian
21. r filter Fix the 3 purifiers on filter install filter on the several bulges on top of air inlet grille pull the handle behind air inlet grille toward inside to fix filter As shown in fig 19 5 Close air inlet grille Refer to the 1 step Maintenance Method 14 Maintenance Method Tt TPR Kx XK RO POO D 1211111 Fig 19 Fig 20 yw Clean air inlet grille 1 Open air inlet grille the same with the Ist step of Clean Air Filter 2 Take out air filter the same with the 2nd step of Clean Air Filter 3 Take out air inlet grille Open air inlet grille for an angle of 45 as shown in fig 20 rise it 4 Clean Clean it by pubescence brush water and neutral cleaning then throw water or dry it AN note Do not use water above 13 F 45 C to wash the panel to prevent fade or deformation 5 Install air inlet grille refer to 3rd step 6 Install air filter refer to the 4th step of Clean Air Filter 7 Close air inlet grille refer to the Ist step yw Install and change of air purifier 1 Open air inlet grille the same the Ist step of Clean Air Filter 2 Disassembly purifier As shown in fig 21 disassembly air filter screw out fixing bolts fixed on purifier on filter then purifier could be disassembly 3 Take out the package sack of static fiber net filter then install the filter in stand of purifier and fix purifier on air filter 4 Install air filter the sam
22. s 22 4 9 in 370 mm 23 7 9 in 604 mm 25 3 5 in 650 mm a 0 ee k E _ 26719 in 680 mm Gaps between hoisting screw rods a __33n 840 mm Indoor unit ____35in 8 90mm Ceiling opening 37 2 5 in 950 mm Decorated surface boards Install dimension of mode A Fig 2 The drilling of holes in the ceiling must be done by the professional personnel Installation stands for main body of the unit ee VLILI LLALA N A SALIAS A A EAA E re E E eee ee f s4 N Ceiling 160 mm Fig 3 Notes The dimension for the ceiling openings with marks can be as large as 35 5 6 in 910 mm But the overlapping sections of the ceiling and the decorated surface boards should be maintained at no less than 4 6 in 20 mm Main body of hoisting air conditioner The primary step for install the indoor unit When attach the hoisting stand on hoisting screw do use nut and gasket individually at the upper and lower of the hoisting stand to fix it The use of gasket anchor board can prevent gasket break off 2 Use install cardboard Please refer to the install cardboard about the dimension of ceiling opening The central mark of the ceiling opening is marked on the install cardboard Install of The Compact Panel Cassette Type Indoor Unit Install the install cardboard on the unit by bolt 3 piece and fix the angle of the drainage pipe at the out
23. ter had been installed well In order to start up the air conditioner smoothly after long time s turned off turn on the main power supply 8 hours before turning on the air conditioner Maintenance after usage season Clean filter and body of air conditioner Cut off the main power supply of air conditioner The cooling or heating capacity and sound level are tested before leaving factory If the parameter changed refer to the data offered on nameplate 16 Copyright 2014 Carrier Corporation 7310 W Morris St Indianapolis IN 46237 Edition Date 11 14 Catalog No 40GJC 010M Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Replaces New 66129917011
Download Pdf Manuals
Related Search
Related Contents
56-2990 PC 250 Instruction New 取扱説明書 DPS-L / M デイリープラス Rose CrystalView DVI Fiber Manuel d`utilisation Pilulier électronique semainier 4 alarmes (réf Tender Document RobovieMaker for VS-RC003 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file