Depth Panel User Manual - Scientific Data Systems

image

Contents

1. o 4 2 T 2 o Eo a Sa WIRELIST DEPTH PANEL R9 USB Rear Panel Connectors DC Power In J1 A J10 1 12V Battery J1 B SW2 2 5 GND LUG Chassis Ground Line Weight Input from Transducer J2 A J2 E GND J2 B J11 3 4 20ma Signal J2 D J11 4 12 Excite J2 E J5 F J2 A GND Line Weight Retransmit to System J3 C J11 10 PAX Analog 19 0 20 Out J3 D J11 9 PAX Analog 18 0 20 Out External Lamp or Alarm J4 A 2 2 12 Reg J4 B PCB J9 8 External Lamp Quadrature Encoder Input J5 A 3 1 Encoder A J5 B PCB 3 2 Encoder B J5 D PCB 3 3 Encoder Power J5 F J2 E J6 F GND Buffered Quadrature to System J6 A PCB J1 4 Buffered A J6 B PCB J1 5 Buffered B J6 F J5 F J7 F GND Buffered Quadrature Spare J7 A PCB J1 2 Buffered A J7 B J1 3 Buffered B J7 F J6 F GND LUG GND USB Port to Computer Connected Directly to Board 10 24 2001 Front Panel Controls J10 1 J1 A 12V Battery J10 2 BZ Reg 12V LED J10 3 PCB_J9 5 Mute Switch J10 4 PCB_J2 4 Switched 12 Volt J10 5 PCB_J8 2 Led Control J10 6 GND LUG GND Front Panel Controls
2. 11 8 18 11 9 0 20 Out PAX 19 11 10 0 20 Out PAX 20 11 11 21 11 12 TNS ALM Depth and Li ne Speed DEPTH Meter TBA Control DP_TBA 3 LS 3 2 1 12 _ 5 _ 8 DP_TBC 5 _ 7 LS 7 SW2 6 PGM Mode DP TBA 8 DP TBA 10 GND DP TBA 9 PCB J9 2 Depth ALM DP TBA 10 DP TBA 8 LS 1 GND DP TBA 11 PCB J1 1 Reset Depth Meter TBC Depth DP TBC 1 DP TBC 5 2 3 GND DP TBC 2 LS TBC 2 PCB_J1 7 DIR DP 3 LS TBC 3 J1 6 PPR DP TBC 5 DP TBA 5 DP TBC 1 GND Depth Meter TBD Communications DP TBD 1 PCB J6 2 Meter Communications DP TBD 3 DP TBD 5 Meter Communications DP TBD 4 LS TBD 5 Meter Communications DP TBD 5 DP TBD 3 Meter Communications DP TBD 6 LS TBD 7 Meter Communications DP TBD 7 LS TBD 3 Meter Communications Line Speed Meter TBA Control LS 3 DP TBA 3 412V LS TBA 5 LS 8 LS 5 GND LS TBA 7 DP TBA 7 PGM Mode LS TBA 8 LS TBA 10 LS TBA 5 GND LS TBA 9 PCB J9 3 SPD ALM LS TBA 10 LS TBA 8 GND Line Speed Meter TBC Depth LS TBC 1 LS TBC 5 DP TBA 1 GND
3. PCB_J6 4 LS_TBD 1 Meter Communications PCB_J8 1 GND PCB_J8 2 Led Control PCB_J9 1 PCB_J9 2 Depth ALM PCB_J9 3 SPD ALM PCB_J9 4 TNS ALM PCB_J9 5 Mute Switch PCB_J9 8 External Lamp PCB_J9 9 Buzz Control Misc Items Fuse F1 2 SW1 2 12V Battery F1 2 P10 1 Fused 12V Power on off SW1 1 P10 4 Switched 12 Volt SW1 2 F1 1 Fused 12V Program Mode SW2 2 SW2 5 GND SW2 3 J11 5 PGM Mode SW2 5 SW2 2 GND SW2 6 DP TBA 7 PGM Mode Mute Button SW4 1 P10 6 GND SW4 2 P10 3 Mute Switch LED Alarm Indicator RED P10 2 Reg 12V LED WHT P10 5 Led Control BUZZER BZ J4 A Reg 12 BZ PCB_J9 9 Buzz Control GND LUG J2 3 PCB_J1 9 J10 6 J11 2
4. can be selected by pressing the DISP key The line tension meter contains the alarm for maximum line tension If the line tension becomes greater than this maximum it will activate the over tension alarm Any of the alarms will activate an audible alarm front panel LED and a rear panel external connector The audio alarm can be silenced for the duration of the cause of that alarm by pressing the ALM DIS button Once the alarm condition has passed the audio alarm will be enable again for the next alarm To enter a new preset depth on either depth meter press the P2 key of that meter The last preset depth will be displayed The key directly under each digit will change the value of that digit After the desired changes have been made press the E Key to enter the value into preset depth memory To update the depth to the preset value press the R key to reset the depth To enter new alarm values on either depth meter press the P1 key of that meter After changes have been made press the E key to enter the value into preset alarm memory To enter a new alarm value on the line tension meter press the PAR key The F1 key and F2 key can then be used to change the value Press the PAR key again to store the new alarm value Depth Panel Circuit Description Power from the battery is routed to the PC board and regulated to approximately 11 5 volts and 5 volts by Q1 D1 and U1 respectively Encoder power may be selected from these two voltages by J
5. 10 1 1 2 12 10 2 LED RED Reg 12V LED P10 3 SW4 2 Mute Switch P10 4 SW1 i Switched 12 Volt P10 5 LED WHT Led Control P10 6 SWA 1 GND Line Tension Meter J11 1 J2 1 Reg 12 Volt J11 2 GND LUG GND J11 3 J2 B 4 20ma Signal J11 4 42 0 12 Excite 11 5 SW2 3 PGM Mode J11 6 PCB J4 1 DR J11 7 PCB_J4 2 DR J11 8 GND LUG GND J11 9 J3 D PAX Analog 18 0 20 Out J11 10 J3 C PAX Analog 19 0 20 Out J11 11 GND LUG GND 9 4 TNS ALM Line Tension Meter 11 1 1 Reg 12 Volt 11 2 2 11 3 4 4 20 Signal 11 4 6 12 Excite 11 5 8 Mode 11 6 12 DR 11 7 13 DR P11 8 PAX 14 GND 11 9 18 0 20 Out 11 10 19 0 20 Out 11 11 20 11 12 21 TNS ALM Line Tension Meter PAX 1 11 1 Reg 12 Volt PAX 2 PAX 7 GND PAX 4 11 3 4 20 Signal 6 11 4 12 Excite 7 2 8 11 5 12 11 6 DR PAX 13 11 7 DR PAX 14
6. 3 27 2002 26 1 Depth Panel Depth Tension Line Speed Panel USB 9 The Depth Line Speed and Line Tension Panel uses three industrial process meters to provide simultaneous digital readout of the three measurements Meter 1 is setup in a counting mode and can accommodate virtually any encoder resolution Meter 2 is setup in a rate counter indicator mode and runs from the same encoder signals as Meter 1 Meter 3 senses a 4 20 ma signal from a pressure transducer connected to the measure head weight indicator system Meters for other types of line weight sensor are available The panel is intended to be powered by a 12 volt battery and contains power supply providing regulated 12 0 volts and 5 0 volts for indicator and encoder power The panel also provides 24 volts excitation for the pressure transducer The encoder pulses are converted to depth and direction signals and routed to the depth and line speed meters and are also buffered and output to the rear panel connectors for input to the logging system A retransmitted 4 20 ma signal is also available at the rear panel also for input to the logging system DEPTH PANEL REAR PANEL JE J5 J4 J3 12 v POWER External TENSION BUFFERED ENCODER Alarm TRANSDUCER USB ENCODER h OUTPUT RETRANSMITTED TENSION TRANSDUCER STIP REAR PANEL The above diagram illustrates the connections to the rear of the depth panel and the connections between the depth
7. LS 2 DP TBC 2 DIR LS 3 DP TBC 3 PPR LS TBC 5 LS TBA 5 LS 1 GND Line Speed Meter TBD Communications LS TBD 1 PCB J6 4 Meter Communications LS TBD 3 DP TBD 7 Meter Communications LS TBD 4 PCB J6 1 Meter Communications LS TBD 5 DP TBD 4 Meter Communications LS TBD 6 PCB J6 3 Meter Communications LS TBD 7 DP TBD 6 Meter Communications Encoder Connections PCB_J1 1 DP_TBA 11 Reset PCB_J1 2 J7 A Buffered A PCB_J1 3 J7 B Buffered B PCB_J1 4 J6 A Buffered A PCB J1 5 Je B Buffered B PCB J1 6 DP TBC 3 PPR PCB J1 7 DP 2 DIR PCB J1 9 PCB J3 4 GND LUG GND 12 Volt Power Distribution PCB J2 1 DP TBA 3 1 1 Reg 12 Volt PCB_J2 2 J4 A Reg 12V LED amp Buzzer PCB_J2 3 DP_TBC 1 GND LUG GND PCB_J2 4 J10 4 Switched 12 Volt PCB_J3 1 J5 A Encoder A PCB_J3 2 J5 B Encoder B PCB_J3 3 J5 D Encoder Power PCB_J3 4 PCB_J1 9 GND PCB_J4 1 J11 6 DR PCB_J4 2 J11 7 DR PCB_J6 1 LS_TBD 4 Meter Communications PCB_J6 2 DP_TBD 1 Meter Communications PCB_J6 3 LS_TBD 6 Meter Communications
8. P1 and JP2 DO NOT JUMPER BOTH AT THE SAME TIME The encoder pulses are buffered by the line receiver IC2 and routed to the depth and line speed meters and to the rear panel connectors The line tension sensor is powered by 18 volts from the line weight meter and the signal routed back to the meter This signal is retransmitted to a connector on the rear panel The process meters are connected so that they are fully programmable only when the switch S2 is held open This is to prevent inadvertent reprogramming from the front panels of the meters 26 6 3 27 2002 26 7 Depth Panel Interconnection Cables The cable to connect the depth panel buffered encoder output to the tool interface panel has the following connections Depth Panel 7 Pin Female Interface Panel 7 Pin Male SSeS D 0 G The cable to connect the depth panel encoder input to the depth encoder has the following connections Depth Panel 7 Pin Male Depth Encoder 7 Pin Female D mn cable for the retransmitted line tension from the depth panel to the system tool interface panel has the following connections Depth Panel 5 Pin Female Interface Panel 5 Pin Male B E E The cable for the depth panel line tension input to the pressure transducer has the following connections 26 7 3 27 2002 26 8 Depth Panel Depth Panel 5 Pin Male Pressure
9. Transducer D 1 Excite Usually Red 2 Signal Usually Black A E S Shield 3 Case E 26 8 T 19945 985 21 20 1002 61 6 19380 care su 015 231111 INI SH31SAS 9190 1411 3105 nse 94 120082 MZ WHO 02 200001 612 90 9 212124 914 ese p 86 8821 2190001 981 981 vu ANMTOONRDMD 034341404 119945 86 21 20 1002 61 6 19220 148qunwN dE T GLSNYddo 37111 NOS dETPTLOH SWSLSAS 9190 OIJILN3IOS 14119 05 di 1100 2100 SNIL 03395 d T ANMTOONDM 6X TONO Li 9 99859650 ZEZ 54 SU3134 OL 1n07I 1n0 I 2 NII TANTI of 9007 14384905 T 21901 9 5 1 398012 1994 86 21 20 1002 61 6 19320 JUSWNDOG 01 0 291111 fSH31SAS 9190 21411 3125 0 X oe ONS 0081 00X1 13d 1 1 33852 EUd 330 2Ud OTETZNY 221 deed Irc 621
10. ate and Output2 to Counter 52 6 Set Rate Alarm control to Boundry 53 0 01 Set Rate Time Delay to minimum 54 3 Set Counter Termination to Terminate at Reset 55 0 01 Set Counter Time Delay to minimum 56 2 Set Reset Counter to Preset 2 61 4 Set Right hand Dummy Zeros to None 62 1 Set Time Rate to 1 Second 63 1 Set Rate Update Time 64 3 Set Rate Scale Multiplier to 10 65 2 Set Rate decimal point and leading zero blanking 66 2 Set Operator enabled functions to Reset and Preset only With the settings above to read out in feet per minute or meters per minute Scale factor 60 divided by encoder pulses per foot or meter JP5 Setting 120 ppr 400 ppr 600 ppr 1200 ppr 1 2 No Divide 0 5000 0 1500 0 1000 0 0500 3 4 2 1 0000 0 3000 0 2000 0 1000 5 6 4 2 000 0 6000 0 4000 0 2000 7 8 8 4 0000 1 2000 0 8000 0 4000 Scale factor for the Depth 2 Counter is the same as the Depth 1 Counter above 26 3 3 27 2002 26 4 Depth Panel Setup of Line Tension Programming may only be accomplished by activating the program enable switch at the rear of the panel Press the PAR Parameters key to enter program mode and select parameter groups Use the F1 and F2 keys to change selections Set each of the program groups as follows 1 INP Input Parameters Display Parameter Setting rAn6E Input Range 20MA 0 02A dECPt Display Resolution Full Lbs 0 rou
11. e Alarm Limit 1000 HYS 1 Setpoint Hystersis 2 tOn On Time Delay 0 0 tOF 1 Off Time Delay 0 0 out 1 Output Logic nor rSt 1 Reset Action AUto Stb 1 Standby Action NO Lit 1 Output Panel Light nor Alarm limit value that can be changed from front panel after programming 7 SrL Serial Communications Parameters Display Parameter Setting bAUd Baud Rate 2400 dAta Word Length 7 PAr Parity Odd Address 2 Abrv Abbreviated nO OPt Options nO 8 Out Analog Output Parameters Display Parameter Setting tYPE Analog Type 4 20 ASIn Analog Assignment InP An LO Analog Low Scale Value 0 00 Analog High Scale Value 10000 Update Time 0 0 9 FCS Factory Service Funtions Display Parameter Setting Code Service Access Code Restore Factory Setup 50 Normally will show 50 To clear all settings to factory defaults enter code 66 26 5 3 27 2002 26 6 Depth Panel Depth Panel Operation Depth entries and alarm setup points are entered from the key pads of each meter Depth1 meter contains the alarm for minimum depth If the depth counter becomes less than this minimum it will activate the depth alarm Depth2 Line Speed meter contains the alarm for maximum line speed If the line speed becomes greater than this maximum it will activate the overspeed alarm Depth2 meter will display both a depth and the line speed which
12. nd Display Rounding Increment 1 FILtr Filter Setting 2 0 bAnd Filter Enable Band 10 PtS Scaling Points Use 2 of 16 possible 2 StYLE Keyboard Entry or Calibration Applied KEY or APLY InP 1 Low Input reading in MA 4 000 dSP 1 Low Display Value in Pounds Kilos 0 InP 2 High Input reading 20 000 dSP 2 High Display Value in Pounds Kilos 10000 values for a 4 20ma sensor 0 10000 Ib Calibration 2 FNC External Input and Function Key Parameters Display Parameter Setting USr 1 User Input 1 PLOC USr 2 User Input 2 nO USr 3 User Input 3 nO F1 Function Key 1 nO F2 Function Key 2 nO rst Reset Key nO Sc F1 Secondary Function Key 1 nO Sc F2 Secondary Function Key 2 nO 3 LOC Parameter Lockouts Display Parameter Setting HI Maximum Reading Display LOC LO Minimum Reading Display LOC tOt Total Reading Display LOC SP 1 Setpoint 1 Entry Enabled Ent SP 2 Setpoint 2 LOC SP 3 Setpoint 3 LOC SP 4 Setpoint 4 LOC CodE Security Code 0 26 4 3 27 2002 26 5 Depth Panel 4 SEC Secondary Function Parameters These parameters are not used at this time 5 tOt Totalizer Parameters These parameters are not used at this time 6 SPt Setpoint Parameters Display Parameter Setting SPSEL Select Setpoint SP 1 ACt 1 Action for Setpoint Absolute High Ab HI SP 1 Setpoint Valu
13. panel and the SDS tool interface 26 1 3 27 2002 26 2 Depth Panel The Depth Panel is shipped from SDS with the process meters setup as indicated below These settings should be the most appropriate with optional settings as indicated Setup for Depth Counter 1 Two sets of DIP switches must be set for proper function of the Depth meter Switch one is located on the back of the meter Switch two is located on the right side as viewed from the front SW 1 On Meter 1 4 7 8 ON DOWN and 2 OFF UP SW 2 On Meter 1 2 ON DOWN 3 4 5 6 7 3 6 7 8 9 10 OFF UP Programming may only be accomplished by activating the program enable switch at the rear of the panel Other than changing the scale factor re programming should only be necessary upon installation of a new meter CODE ENTRY 41 1 Set unit personality to COUNTER 43 2 Set inputs to COUNT with UP DOWN Control 44 1 Set to SINGLE EDGE COUNTING 45 2 Set scale multiplier to 01 46 2 Set decimal point and leading zero blanking 51 2 Set reset mode to manual reset to preset 52 6 Set Output1 Alarm control to Boundry 53 0 01 Set Output1 Time Delay to minimum 54 3 Set Output2 Termination to Terminate at Reset 55 0 01 Set Output2 Time Delay to minimum 61 4 Set Right hand Dummy Zeros to None 66 2 Set Operator enabled functions to Reset and Preset only With the settings above to read out in feet o
14. r meters Scale factor 100 divided by encoder pulses per foot or encoder pulses per meter 120 400 600 1200 HE3 Seming Encoder Encoder Encoder Encoder 1 2 No Divide 0 8333 0 2500 0 1667 0 0833 3 4 2 1 6667 0 5000 0 3333 0 1666 5 6 4 3 3333 1 0000 0 6666 0 3333 7 8 8 6 6666 2 0000 1 3333 0 6666 Scale Factors Note placing a sign in front of scale factor reverses encoder direction 26 2 3 27 2002 26 3 Depth Panel Setup for Depth Counter 2 Line Speed Two sets of DIP switches must be set for proper function of the Depth Line Speed meter Switch one is located on the back of the meter Switch two is located on the right side as viewed from the front SW 1 On Meter 1 4 7 8 ON DOWN and 2 3 5 6 OFF UP SW 2 On Meter 1 2 10 ON DOWN and 4 5 7 8 9 OFF UP Programming may only be accomplished by activating the program enable switch at the rear of the panel Other than changing the scale factor re programming should only be necessary upon installation of a new meter CODE ENTRY 41 1 Set unit personality to RATEMETER COUNTER 42 3 Set Reset for both Rate and Counter 43 2 Set inputs to COUNT with UP DOWN Control 44 1 Set to SINGLE EDGE COUNTING 45 2 Set scale multiplier to 01 46 2 Set counter decimal point and leading zero blanking 51 1 Set Output1 to R