1. 8 0 5 4 Personal protective 8 0 5 5 First Ald aea tace se tap Pee RR 9 0 5 6 Storage of AdBlue Een rd 10 0 5 7 Spillage of SLT TEE 10 1 ADBLUE DISPENSERS TATSUNO BENG sccscssssscssssssssssssesssssssesscsssscsssssssesssssssessssnsssescensnsess 11 1 1 BASIC SPECIFICATIONS ERER Rara EE 11 1 2 ADBLUE DISPENSER DESCRIPTION ettet tette tette tette ns 12 1 3 SURVEY OF AVAILABLE TYPE MODELS essen 14 1 3 1 Dispenser marking seasann eaae raa ena eere E a Eaa r ar E ESS 14 1 3 1 AdBlue Dispenser models ee eterne tenente 14 1 3 2 Dimensions amp Weights rennen 14 1 3 3 AdBlue Dispenser 15 2 INSTALLATION e 17 2 1 OCCUPATIONAL SAFETY INSTRUCTIONS nennen netten teen tese tenente 17 2 2 ARRIVAL TRANSPORTATION UNPACKING cerent nennen nennen en 17 2 3 ADBLUE DISPENSER INSTALLATION AND LAYOUT eene tenente nennen 18 2 4 MECHANICAL ADBLUE DISPENSER 4 nennen nennen innen enne 19 2 5 ADBLUEG DISPENSER EL WIRI
2. Enter again displays the number of the parameter i e displays the line K litr unit grade price 4 Change editing of parameter value by the key Enter 5 Mode exit by the key lt REG gt Viewing of the parameters totalizers in the operator mode is done in the same way When depressing the key Shift lt REG gt the first parameter 01 will appear automatically Switching between the parameters by the keys lt Next gt and Shift lt Next gt between sub parameters by lt gt lt Shift gt lt gt By depressing the keys 1 and 2 parameter values can be monitored Operator mode exit by depressing the key lt REG gt 3 1 3 Data Monitoring in Setting Mode All data in the setting modes are displayed on the dispenser display When controlling by the remote controller the data are displayed on the dispenser side which the setting mode was recalled from by the controller Individual parameters are displayed as follows 00003 2 wii 7890 13 1 0 1 a L2 Pri Parameter number 01 Item numbet 2 Auxiliary code L Parameter value 327890 13 Auxiliary code Parameter number Fig 5 Example of parameter displaying 27 Version 2006 04 07 Bene INSTALLATION AND USER MANUAL ATI INC ADBLUEG DISPENSERS SHARK 3 1 4 Operator Mode The operator mode is started by pointing the dispenser display by the IR remote controller at the distance of ca 1 m from the dispenser
3. 4 3 2 Correct AdBlue Nozzle Usage dies echa pte 42 4 3 3 AdBlue Thermostat and Heaters ettet ttt tette tette etatis 43 4 3 4 Prezselection KeybO td e tre pedea 43 4 3 5 Electromechanical Litre Totalizers eee sese eee enne eene ennt 44 4 3 6 AdBlue dispenser Display Back lighting ettet 44 4 3 7 Signaling Diode SIG on the Display eese ener enne eene nene 44 4 3 8 Signaling Diode PWR on the Display seen 44 4 4 END OF ADBLUE DISPENSER OPERATION sscssssssssssssssscscssssscssssssusscsessusscesssessesessusscsessesscseeseeses 44 5 MAINTENANCE AND SERYV ICE ee oet o e XV a 45 5 1 SURVEY OF MAIN PRINCIPLES OF ADBLUE DISPENSER MAINTENANCE 45 5 2 PRINCIPLES OF ADBLUE DISPENSER CHECKING cette netter tens 46 5 3 ADBLUE DISPENSER ERROR MESSAGES retener retener tenis 46 5 4 DISPENSER SERVICE o nititur esa tst ete itat a ete t mete ut 46 5 5 WARRANTY AND COMPLAINTS einen aE tentent ettet entes teet tnnt 47 2 0 ACCESSORIES re RR rae e eae nor hace ERE x 47 APPENDICES APPENDIX ERROR MESSAGES APPENDIX B FOUNDATION PLANS amp FRAMES APPENDIX C ELECTRICAL SCHEMES APPENDIX D CERTIFICATES Version 2006 04 07 INSTALLATION AND USER MANUAL CB Y Introductory Information 0 1 Pictograms and Terms Used in
4. causing danger to all persons on the forecourt Take extra care in cold weather as the flexibility of the hose decreases and the ease of retraction is reduced 9 Ensure that the hose does not obstruct public passage nor constitute a trip hazard 10 Release nozzle trigger s when the required amount of fuel has been dispensed or until your tank s is are filled the delivery will cease automatically at this point 11 Remove the AdBlue nozzle from the AdBlue tank inlet and replace it in its holder refer to section 8 3 1 for correct AdBlue nozzle usage 12 Disconnect the adaptor where fitted 13 Ensure that payment is made as required 14 Drive away from the filling position slowly and carefully 4 3 2 Correct AdBlue Nozzle Usage AdBlue dispensers ate supplied with a special Elaflex AdBlue nozzle fitted to the end of the hose As a safety feature this nozzle may contain a magnet which only allows insertion of the AdBlue nozzle into dedicated AdBlue vehicle tanks Always follow the nozzle instructions positioned near the nozzle boot on the dispenser to ensure optimum cusomer safety and correct operation when dispensing AdBlue liquid The following directions are guidelines for using the most common AdBlue nozzle found on TATSUNO BENC dispensers In order to reduce the likelihood of AdBlue liquid freezing in the hose and nozzle the AdBlue nozzle is protected by a nozzle door Refuelling with the
5. or if his knowledge is insufficient to carry out such work he must immediately inform his superior about the detected safety deficiency Version 2006 04 07 INSTALLATION AND USER MANUAL v C Bene ADBLUE DISPENSERS SHARK This equally applies to 1 Work Materials which have not been correctly packed or correctly marked in order to meet safety requirements 2 Work Methods or work processes which have not been correctly coordinated or controlled in order to meet safety requirements 3 Where dangerous activities are carried out by several persons the need for a permanent faultless communication between them in order to avoid dangerous events shall require the appointing of one person in order to carry out overall supervision 0 5 3 Hazards Prior to starting work the dispenser must be isolated i e entirely disconnected from the mains supply and the mains supply switch locked in the OFF position The submerged pump if applicable and control signals from the dispenser must also be isolated This is done to provide safety for the technician As a further precaution switch off the mains supply in the service station shop and place a clear notice on the switch to avoid it being turned on again inadvertently It is not permitted to put a AdBlue dispenser into operation before an authorised official has inspected it and released it This depends upon the national regulations in force Dismantled packaging and cladding must be sto
6. 2006 04 07
7. 3 1 5 7 Displaying of History of Dispensing code 07 eese enne 31 3 1 5 6 Access Password code 06 esses sees eene eene enne tenerse nennen nnns 3l 3 1 5 9 History of Maintenance code 09 eene nennen 32 3 1 5 10 Operating AdBlue Dispenser Mode code 12 sees 32 3 1 5 11 Error Statistics code 13 esses eene ennt entren eene nennen nns 32 3 1 5 12 Current Operating Temperature code 14 essen 33 3 1 5 13 Daily Totalizer Resetting code 15 eese teen nnne nene 33 3 1 5 14 Operating Check Number code 16 essere eene 33 3 1 5 15 Text messages CODE 10 n eee 33 3 1 5 16 Displaying of Display Segment Error code 19 2 eee 35 3 2 CALCULATORS PUMA HT TE AND PUMA seen enne nennen nennen 35 3 3 CALCULATORS ADP M AND nennen enne nent enitn 36 4 OPERATION o ccsseuthccesescescesuscesceusccesessoscesecss scouessesdescssecsesescesuacsascesscassesse 39 4 1 INSTRUCTIONS FOR SAFE OPERATION cccssccesscecesecesscecsceesececsuceeeeeceaeeeneeceaseesaeecaceeeneecaeeeeaters 39 4 2 PUTTING ADBLUE DISPENSER INTO nennen enne nene 40 4 3 OPERATION OF ADBLUE DISPENSER scssscecssrcesseecseeeseeecesececeeceaeeesaeecsaeeeeaeecaceseneecsaeeeeaters 41 4 3 1 Dispensing AINE Soo secnm m Mit em ds M Ut E 41
8. Color version Possible Cable type Function current of wires of wires equivalent mm CMSMaRg ig es 3 18 ZZ C C CMSM3Bx25 switching calculator feeding CMSM 5C x 1 5 PDE ADP or 5 15 ZZ 3xC SM CMSM 5 2 5 ADPMPD calculator feeding CMSM 3C x 1 5 Puma HT TE 3 18 ZZ H SM CMSM 3C x 2 5 Puma MPD TRA SM TCEKFE 2P 1 0 CMSM 4D 1 5 communication line 4 15 ST Belden 88723 Notes ZZ green yellow brown C black M blue SM light blue ST shield Table 7 Characteristic features of cables RECOMMENDATION The pulse overvoltage can take place in any line due to lightning up to the distance of several kilometers or due to industrial activities The pulses arisen by lightning induction are quite enough for full destruction of the electronic unit For this purpose the advanced countries usually apply the ovetvoltage protection leading the ovetvoltage pulse power away into the earthing conductor thus protecting the unit in question Therefore the manufacturer of AdBlue dispensers recommends to protect the main and or the secondary switchboard feeding the AdBlue dispenser electronic unit computer POS etc and the data lines by overvoltage protection and lightning atresters RECOMMENDATION In order to provide trouble free operation of AdBlue dispensers it is necessary to secure the stabilized AdBlue dispenser feeding by the standby source UPS Power supply dropouts heavy
9. IS ENERGIZED Electric and electronic parts assemblies may be serviced only and exclusively by the specialist liable for safety of the device After completed intervention the conductors must be reinstated Correct conductor installation must prevent any contact with the moving parts of the winding module Caution After each service intervention tightness of hydraulic assemblies has to be inspected possible medium leaks have to be removed 5 1 Survey of main principles of AdBlue dispenser maintenance e maintain all AdBlue dispenser assemblies clean so that possible unforeseeable fault can be identified easily and removed quickly e check condition of the nozzle and decide its repair or replacement depending on revealed defect e check door locks and nozzle accommodation boot for correct functioning e maintain the AdBlue dispenser clean pay attention particularly to cleanliness of calculator glass e lubricate the nozzle by silicone oil twice a week Maintenance of AdBlue dispenser body Parts of the AdBlue dispenser body lacquered or made of stainless steel need regular maintenance A great attention shall be paid to these parts particularly in winter season because aerosols of chloride preparations arisen from the salts used for road maintenance can result in permanent damage of lacquers of untreated body parts and or to intercrystalline corrosion guards made of stainless steel Regular main
10. NN ADBLUED DISPENSERS SHARK IAISUNQ S Send 1 The user can switch the mode of unit price setting by depressing the key 0 2 Inthe mode of unit price setting see Fig 13a e the first display line i e the line of the total price the number of the side which the unit price is set for will be displayed 1 page 2 page e the second display line i e on the line of the total volume the number of the nozzle which the unit price is set for will be displayed i e for ADP2 M always the nozzle No 1 the third display line ie on the unit price line the number representing the value to be set by the user will blink 3 User e using the key increases the value of the currently set i e blinking digit the value 9 is changed to 0 by depressing the key the user can scroll through the values 0 9 i e the auto repeat function e using the key shifts setting towards higher figure orders e from the highest order of the unit product price see the Fig 13b using the key shifts setting to the lowest order of the unit product price of another side see Fig 13c 4 This way the user can set the price for the side A and then for the side any and its product has a different price see the parameters No 46 5 The user can end setting of unit price values at any time by depressing the key 0 6 The set unit prices are written into the non
11. Pmax 0 6 MPa 6 bar Accuracy of dispensing 0 5 Operating temperature of the ambient air 30 50 C Electronic calculator Power 230 V 10 15 50 Hz 5 Hz max 84 VA Electromagnetic valves 24V DC max 0 500A Displays a 7 segments LCD displays with LED backlight type PDEDIL volume 0 01 az 9999 99 dm amount 1 to 999999 currency unit unit price 1 to 9999 currency unit dm figure height amount 2 54 mm 1 volume 2 54 mm 1 unit price 2 54 mm 1 b Alphanumeric LCD displays with LED backlight type PDELCD volume 0 01 to 9999 99 dm amount 1 to 999999 currency unit unit price 1 to 9999 currency unit dm figure height amount 40 mm 1 volume 2 54 mm 1 unit price 2 54 mm 1 Electromechanical volume totaliser 0000000 9999999 dm 11 Version 2006 04 07 C f N INSTALLATION AND USER MANUAL 2 ADBLUEG DISPENSERS SHARK 1 2 AdBlue Dispenser Description The AdBlue dispensers TATSUNO BENC version SHARK have the body parts guards doors covets made of fireproof laminate reinforced plastic approved for the scope of use by the State Test Laboratory Certificate of FTZ 04ST 0083 Supporting dispenser skeleton parts are made of steel lacquered sheet 0 8 1 mm thick and or of stainless sheet Standard colour version of the AdBlue dispensers TATSUNO BENC combination of white MM710 and grey colour RAL7040 Each AdBlue dispenser is equipped by the hydraulic unit of the Japan
12. ZVA AdBlue nozzle is only possible in combination with the ELAFIX 40 magnet adapter The fixed magnetic field within the filler neck opens the magnet switch in the spout so misfuelling into petrol or Diesel tanks is made impossible Vice versa the filling of the AdBlue tank with fuel is also excluded because petrol and Diesel spouts do not fit into the ELAFIX 40 magnet adapter see Fig Nozzle ZVA AdBlue Elaflex Hose Magnet Adapter ELAFIX40 s LL AdBl e 7 Fig 11 Example of canister refuelling with ZV A_AdBlue Nozzle and Magnet Adapter 42 Version 2006 04 07 INSTALLATION AND USER MANUAL Y The following instructions must be followed to ensure safe operation of the AdBlue dispenser 1 Where applicable remove the cap of the vehicle tank Check and remove any foreign matter 2 Open the door and remove the AdBlue nozzle 3 Extend the hose as required to insert the AdBlue nozzle into the vehicle AdBlue tank inlet 4 When filling is complete open the nozzle door and replace the nozzle securely in the nozzle boot 5 Where applicable refit the vehicle filler cap ATTENTION Avoid spillage of AdBlue onto the forecourt as this will cause a slippery surface Ensure the nozzle is correctly stowed onto the hook before closing the door 4 3 3 AdBlue Thermostat and Heaters All AdBlue dispensers are fitted with thermostatically controlled heaters designed to p
13. a way that the nozzle and hose need to be pulled over your vehicle in order to insert the nozzle in the tank opening 2 Apply the handbrake and switch off the ignition Switch off mobile telephones and extinguish any other sources of ignition e g cigarettes 3 Where applicable remove the cap of your vehicle tank opening s 4 Remove the AdBlue nozzle from the dispenser housing and insert into the vehicle tank inlet Refer to section 8 3 1 for correct AdBlue nozzle usage The AdBlue nozzle may be fitted with a magnet which automatically opens the AdBlue vehicle tank to allow insertion of the nozzle ATTENTION TATSUNO BENC generally advise against the use of adaptors however where they have to be used the adaptor must be connected first to the vehicle tank then thedispenser nozzle is connected to the adaptor 5 Ensuring the AdBlue nozzle and diesel nozzle where applicable is securely inserted into the vehicle tank opening commence filling 6 Verify that the calculator resets to display zero for the total volume and amount to pay 7 and where applicable the correct unit price for the selected fuel 41 Version 2006 04 07 d INSTALLATION AND USER MANUAL gt Nn Bent 8 Do not pull on the hose violently and do not allow it to be crushed flattened or kinked Avoid any contact between the hose and the exhaust pipe on the underside of your vehicle A hot exhaust could burn the hose
14. after AdBlue dispenser display resetting The current time has to be set after the AdBlue dispenser is switched off and on the current time setting is reset after the AdBlue dispenser is switched off The text message No 21 if permitted current date It will appear on the display always after AdBlue dispenser display resetting The text messages No 22 and 23 if permitted display the currency and quantity unit in case of data preset on the AdBlue dispenser auxiliary code description 0 Not display the text message 1 1 2 a2 20 Display text message 2 1 2 az 20 Text message editing Table 17 Setting of text message displaying code 18 The parameter may obtain the values from 0 to 2 The manufacturer s setting can be seen in the table 19 Value of the parameter for all text messages equals to 0 for the displays other than the alphanumeric display Messag Character set Default oe Message content e length Latin2 ASCII Cyrilic ae char Win 1251 Win 1251 1 ON 1 Product name No 1 7 Natural BenzBLF 95 1 2 Product name No 2 7 Special Benzin A 76 1 3 Product name No 3 7 Super Super 96 1 4 Product name No 4 7 Nafta Diesel 1 5 Product name No 5 7 Bio Bio 90 1 6 7 Reserved 8 Reserved 9 Text after completed dispensing 8 Zaplatit Payment 0 10 Text a
15. be reset at any time manager mode parameter 15 The daily totalizers show what fuel volume cash was dispensed by individual hoses since the latest resetting aux code item number description L 1 volume dispensed by the hose No 1 in litres A 1 amount dispensed by the hose No 1 in currency L 2 volume dispensed by the hose No 2 in litres A 9 amount dispensed by the hose No 9 in currency L H volume dispensed by the hose No 10 in litres A H amount dispensed by the hose No 10 in currency Table 12 Daily totalizers code 02 29 Version 2006 04 07 SN INSTALLATION AND USER MANUAL IAISUNQ 222 ADELUEO DISPENSERS SHARK 3 1 5 3 Fuel Product Unit Prices code 03 The function enables to display and set current unit prices of all fuel products i e prices per 1 litre of fuel sold for cash item number description default setting 1 unit price of product 1 00 00 2 unit price of product 2 00 00 3 unit price of product 3 00 00 4 unit price of product 4 00 00 5 unit price of product 5 00 00 Table 13 Unit prices of individual fuel products code 03 If the AdBlue dispenser calculator is connected to the control system then the price is updated after each calculator activation namely by the product values set in the control system 3 1 5 4 Current Time and Date code 04 The function enables to display and set the current date and time Setting can be
16. done by depressing the key lt Enter gt and by loading date and time 2405 00 Parameter The first line displays time in the format HHMMSS hours minutes and seconds the second line displays date in the format DDMMYY day month and year example 17 34 50 24 05 00 3 1 5 5 Displaying of Program Version and Check Sum code 05 The function displays the number of the program version of the dispenser calculator and the check sum of memory parameters e Line 1 amount check sum e Line 2 litres version number e g 3 34 version 3 34 3 1 5 6 Displaying of Latest Error Conditions of AdBlue Dispenser code 06 The function serves for displaying of the history of the latest ten error codes of faults occurred on the dispenser Table of error messages can be found in the Appendix D aux code item number description A 0 code of the last tenth error of the dispenser on display side A code of the last tenth error of the dispenser on display side B B 0 A 1 code of the last but one ninth error of the dispenser on side A B 1 code of the last but one ninth error of the dispenser on side B A 9 code of the error first in the history of the dispenser on side A B 9 code of the error first in the history of the dispenser on side B Table 14 Displaying of error conditions of tbe AdBlue dispenser code 06 30 Version 2006 04 07 INSTALLATION AND USER MANUAL AD
17. editing Amt Amt NATURAL NATURAL Ltrs Price Ltrs 3 1 5 16 Displaying of Display Segment Error code 19 The function enables disables displaying of the display segment error EI by the processor Parameter valle Description 0 Do not display the error of the display segment 1 Display the error of the display segment default setting Table 19 Displaying of the display segment fault error code 19 3 2 Calculators Puma HT TE and Puma MPD The calculators Puma HT TE and Puma MPD produced by the company Gilbarco Veederoot S p A the former company Logitron are set by the three key keyboard Fig 6 Keyboard of the calculators Puma HT TE and Puma MPD Functions of the keys are as follows Key Function Entry into the price setting mode after calculator switching m Selection of figures on the unit price display lt gt Value increase Price setting for manual mode Unit price setting is done in the manual mode namely as follows 35 Version 2006 04 07 feud INSTALLATION AND USER MANUAL ADBLUE DISPENSERS SHARK e switching the calculator ON OFF display mask removal depressing the key lt gt the calculator is switched to the price setting mode e sclection of the figure for the price the value of which is to be changed by the key lt gt e setting of the value of the selected figure by the key lt gt display mask
18. of carbon monoxide carbon dioxide nitrogen oxide and ammonia reducing the amount of oxygen in the air In the event of personal contact with AdBlue the following procedures should be carried out immediately Eye injuries If the eyes have come into contact with AdBlue e Pour copious amounts of water over the eyes immediately e Rinse eyes thoroughly by keeping eyes open and eyelids away from eyes e Continue to rinse the eyes with fresh running water for at least fifteen minutes e Removal of contact lenses after an eye injury must be undertaken by trained personnel e Seek medical advice if irritation continues Skin contact burns If the skin has come into contact with AdBlue e Immediately cool affected skin with cold water over the affected area e Carefully remove all clothing which has been in contact with AdBlue e Continue to rinse the affected area with ample water for at least fifteen minutes e Apply antiseptic bandages to the affected areas e Seek medical advice if irritation continues Inhalation of AdBlue luquid ammonia biuret Do NOT enter the danger zone without adequate protection including respiratory mask and or aforementioned protective clothing If any toxic fumes have been inhaled e If possible remove the person out of the contaminated area into fresh air e the person down and loosen their clothing keep warm and rested e If the person is unconscious place them in the recovery position e I
19. of the filling station by emergency symbols The operating instructions of the filling station and or the information about basic obligations must be available for the customer The AdBlue dispenser is activated by taking the nozzle out of the boot which operation resets el calculator data automatically Submersible AdBlue pump will be started and dispensing can be commenced Fuel flow rate is controlled by the nozzle Dispensing is terminated by nozzle locking release of the control lever The nozzle is then pushed into the nozzle boot which leads to switching OFF the pump el motor The data concerning the dispensed volume remains preserved until the next nozzle release or until the relevant cash amount is settled 4 3 1 Dispensing AdBlue The procedure for the AdBlue filling process is different to the one for petroleum and diesel fuels Prior to using the AdBlue dispenser ensure that you have read and understood all safety procedures referred to in section 0 of the User Manual If in doubt about any of the following procedures seek assistance from the Station Operator Always follow the instructions on the AdBlue dispenser ATTENTION Only vehicles equipped with a special AdBlue tank may accept this fuel 1 Select a filling position and park your vehicle in the filling position so that the AdBlue tank opening is adjacent to the AdBlue nozzle Where possible avoid parking your vehicle in such
20. the destruction of NOx through reaction with ammonia resulting in harmless water and nitrogen The Urea solution requited by the SCR system is called AdBlue It is stored in a tank on the vehicle and injected in the exhaust system where the reaction takes place To meet Euro IV expected AdBlue consumption is around 5 of the diesel consumption asking for tank sizes varying from 50 1 to 100 1 For Euro V this consumption is expected at 6 7 0 4 2 AdBlue AdBlue is a solution based on a mix of 32 5 of Urea water and some additives This mixture was chosen because it is has the lowest crystallisation temperature To ensure correct operation of the SCR over its lifetime AdBlue quality needs strict control and is therefore specified in a standard DIN 70070 Further physical properties of the AdBlue AdBlue freezes at 11 C AdBlue is highly corrosive since 67 5 is water AdBlue shows strong crystallisation and creep 0 5 Health amp Safety 0 5 1 Safety checklist Any smell of ammonia must be reported immediately It is obligatory that this checklist be fully complied with during all work at the filling station particularly construction or repair work It is the duty of the contractor to ensure that all workers employed by him obey each and all of the relevant laws directives and other regulations AdBlue liquid must only be stored in AdBlue compatible containers storage tanks Areas where special caution is
21. volatile memory and the calculator returns to the MAN mode Displaying of electronic totalizers Displaying of the electronic totalizer is carried out as follows e the AdBlue dispenser is at rest all transactions are transferred to the POS and all nozzles are suspended in the boot by directing the IR keyboard onto the AdBlue dispenser display and by depressing the key lt gt the volume litre totalizer of the first nozzle will appear e g U0000012345 90 by depressing the key lt gt the sum totalizer of the first nozzle will appear e g 00000235678 9 e depressing the key lt gt volume and price totalizers for other nozzles will appear e totalizet reading is ended by depressing the key lt 0 gt Setting or monitoring of parameters This operation is reserved to service technicians servicemen only 37 Version 2006 04 07 INSTALLATION AND USER MANUAL 2 IAISUNQ Send 2 AD BLUES DISPENSERS SHARK 38 Version 2006 04 07 INSTALLATION AND USER MANUAL CB Y 4 Operation 4 1 Instructions for Safe Operation The AdBlue dispenser is a complex device which must fulfill a number of demanding functions Prior to putting the AdBlue dispenser into operation the following operations have to be carried out a pressure testing of the AdBlue dispenser together with pipe systems by the pressure of 0 35 MPa inspection of el power distribution and check for correct wiring have to be c
22. 07 Height Width Length Weight Type of Dispenser mm mm mm kg BMP201LSSL AdB 1917 520 850 BMP201LSSR AdB 1600 BMP2012 SSD AdB 210 14 INSTALLATION AND USER MANUAL SN 1 3 3 AdBlue Dispenser figures 1 I T ea g a 1 D 9 w e g amp 1 gt aooo T mu mm mu IE ca m cA aw e N ea gt Y 1 a ER ac 25 e 25 oo 7 4 1 e at Y Fig 2 Figures of AdBlue Dispensers 15 Version 2006 04 07 INSTALLATION AND USER MANUAL 2 IAISUNQ Send 2 AD BLUES DISPENSERS SHARK 16 Version 2006 04 07 INSTALLATION AND USER MANUAL Y 4 2 Installation 2 1 Occupational Safety Instructions AA amp e The equipment has to be installed by the staff qualified and authorized pursuant to relevant standards regulations local limitations and pursuant to the Manual e Smoking and open fire handling is prohibited in the vicinity of the dispenser e Always adhere to the rules for AdBlue handling e Monitor all leaks in the dispenser Should you establish AdBlue leaks disconnect power supply line and contact the service organization see Section 5 e El wiring must be carried out by the qualified staff e Assure that the operable fire extinguisher is available e When handling the device use su
23. BLUEG DISPENSERS SHARK ite ML 06A0 Jii Parameter 3 1 5 7 Displaying of History of Dispensing code 07 The function serves for displaying of the history of the latest 10 dispensing transactions on each side realized on the dispenser Data layout of this parameter on the display is as follows 07 77 Fuelling Time Fuelling Date Parameter Parameter aux code item number description A 0 last transaction tenth on side A B 0 last transaction tenth on side B A 1 last but one transaction ninth on side A B 1 last but one transaction ninth on side A A 9 transaction first in the sequence on side A B 9 transaction first in the sequence on side B Table 15 Displaying of the history of dispensing code 07 The first and second line contain price cash amount and dispensed volume The unit price of the transaction with the parameter number and the auxiliary code with the item number take turns on the third line Number of the item means position in the history of transactions 0 is the last newest transaction 9 is the oldest stored transaction The auxiliary code means the dispenser side A or B If the memory stack for the history of transactions is empty i e there is no transaction in the history error appears on the display 3 1 5 8 Access Password code 08 The function enables to display and change the access password into the mana
24. Lt black 1 phase 230V switching elements feeding PE yellow and green protective conductor Table 2 Feeding of calculator PDE ADP M and switching elements Marking of conductors in cable CMSM 3C x 1 5 marking colour description Ns light blue neutral wire of stabilized calculator feeding Ls brown phase 230V of stabilized calculator feeding PE yellow and green protective conductor Table 3 Calculator feeding Puma HT TE PUMA MPD 20 Version 2006 04 07 INSTALLATION AND USER MANUAL o gt eae BEER C PVT Send gt Feeding of switching elements 230V is led from the AdBlue dispenser into the main switchboard where it is connected to the phase 230V through the circuit breaker 230V 2A Feeding of the calculator is led from the AdBlue dispenser into the main switchboard where it is connected to the common bus bar for all AdBlue dispensers through the circuit breaker 230V 230V 2A From hence feeding for all AdBlue dispensers is led into the stabilized standby source which will feed the AdBlue dispenser electronic unit for min 3 5 minutes in case of power drop out The stabilized source is fed by 230V through the circuit breaker 230V 10A It 1s necessaty to separate zero conductors in the switchboard from switching component feeding and from stabilized calculator feeding a separate zero bridge 2 5 3 Communication Line The communica
25. NG eese nennen nen nent tnnt entente entente nen tenter enne 19 2 5 1 Switching of AdBlue submersible pump esee tentent 20 2 5 2 Feeding of Electronic Unit and Switching Elements eene 20 2 5 3 Communication Line eese 21 2 5 4 Characteristic Features of 23 3 BASIC FUNCTIONS AND DISPENSER SETTING eee ee eene tnos 25 3 1 PDE CALCULATOR PUR Ene ER EE 25 3 1 1 Remote AdBlue Dispenser 26 3 1 2 Setting of Parameters on Dispenser with Volume Display eee 27 3 1 3 Data Monitoring in Setting Mode esee enne etre enne 27 344 Operator Mode EE E tique Het boe i ER EHE LIAC Fe ERR HAE eR RC ec Ene ge ONE od 28 3 1 5 Manager Mode enti tee uet que Bs ue pru ne pee R 28 3 1 5 1 Non resetable totalizers code O1 sess sese eene eene nnne nennen nnns 29 31 5 2 Daily totalizers code 02 eei co 29 3 1 5 3 Fuel Product Unit Prices code 03 esee eene nennen nennen 30 3 Version 2006 04 07 3 1 5 4 Current Time and Date code 04 esses eene enne nennen enn 30 3 1 5 5 Displaying of Program Version and Check Sum code 05 eee 30 3 1 5 6 Displaying of Latest Error Conditions of AdBlue Dispenser code 06 30
26. T be installed in hazardous zones 1 or 2 of the service station The following zoning diagram see Fig 2 is a recommendation for the installation of non ATEX certified dispensers on service stations where petrol dispensers are present _ im __ E extent of hose EN extent of hose __ im _ ASINI OY SZ SS p EOS lt x TEST 06060 05 252 22222222222222222220022 WEEE EE EEEXEZ TEI EIA Fig 3 Restricted area for AdBlue dispensers Pos Description Pos Description 1 Plan View not to scale E Extent of hose of the Petrol Diesel dispenser 2 Front Elevation not to scale H Height of vapour barrier 3 Restricted Area Non ATEX AdBlue dispensers must NOT to be installed within this area The diagram is a guideline only and all local and or national prevailing regulations must be apply at all times 18 Version 2006 04 07 INSTALLATION AND USER MANUAL CS y ADBLUE DISPENSERS SHARK TATSUNO ene ATTENTION AdBlue dispensers may not be placed in the dangerous zone El calculators used in these dispensers are of uncased version are placed in the explosion protected zone and separated from all other zones by the partition of type 1 according to EN 13617 1 Taking in view security of operation the AdBlue dispenser has to be installed by the hose in the direction of filling station refueling po
27. TATSUNO o TATSUNO BENC EUROPE A S AdBlue Dispensers SHARK BMP 2000 S AdB Installation and User Manual TATSUNO BENG EUROPE a s 03 04 2006 TB10 ADB V1EN AdBlue Dispensers SHARK BMP2000 S AdB TATSUNO BENC EUROPE a s Prazsk 2325 68 67801 Blansko Tel 420 516 428411 Fax 420 516 428410 Czech Republic e mail benc benc cz http www benc cz Copyright Neither the manual in full nor any part of it may be reproduced without the explicit approval of TATSUNO BENC EUROPE a s Version 2006 04 07 INSTALLATION AND USER MANUAL LIST OF CONTENTS 0 INTRODUCTORY INFORMATION cccsscccssssccsssscccsscscccsssseccsssscsssscccscsscessssssccsssscesessssseeses 5 0 1 PICTOGRAMS AND TERMS USED IN THE MANUAL escceesseceercesseceseeeeneeceseeesnaecenerenaeceseeeenaeceaees 5 0 2 READ THE MANUAL THOROUGHLY FIRST eese enne eene nente ettet enr entente 6 0 3 PERMITTED SCOPE OF USE 6 0 4 BRIEF CHARACTERISTICS OF THE USED MEDIUM ADBLUE sees 6 0 4 1 Legislation and SCR technology esee eene teen eene nennen nennen 6 042 AdBlue ie 7 0 5 HEALTH amp SAFETY 7 0 5 1 Safety Checklist be lette eter tap der eee ae laa 7 0 5 2 Duties of the employees 4 eia etie EHE E rep todas er 7 0 5 3 ZAI ES
28. ages Defect of the AdBlue dispenser leads to locking of the operation of refueling and to displaying of the error message on the AdBlue dispenser display see Appendix A Nearly all error messages may be cleared by nozzle release and back suspension by switching the electronic unit feeder ON OFF and or by depressing 0 on the remote controller only the PDE electronic unit 5 4 AdBlue Dispenser Service e service operations carried out in conformity with the operation rules of the filling station e prior to statt the works the AdBlue dispenser must be put out of operation the AdBlue dispenser must be affixed by a visible label DUT OF OPERATION and the approach lane must be marked by the sign NO ENTRY the AdBlue dispenser must be disconnected from the power source switching OFF the master switch in the switchboard e valves on the supply piping must be closed fully e traffic of the vehicles must be prevented at the distance of 5 m round the AdBlue dispenser in the course of service activities e fire extinguisher must be available for the staff service intervention must be carried out by the trained staff of the service company TATSUNO BENC EUROPE a s Service department Prazska 2325 68 678 01 Blansko Czech republic HOT LINE 420 602 562 277 TEL 420 516 428423 46 Version 2006 04 07 INSTALLATION AND USER MANUAL Y FAX 420 516 428410 5 5 Warr
29. alculator PDE Wires marking in cable 4D x 1 5 Calculator PDE marking colour description A brown communication line A 5V DC or NET A IFSF LON B light blue communication line B 5 DC or NET IFSF LON black 1 not used black 2 not used ST shielding cable shielding Table 4 Communication cable calculator PDE or calcutators IFSF LON 21 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK Wires marking in cable CMFM 4D x 1 5 Calculator ADP or ADPMPD marking colour description DC brown communication line DATA DC light blue communication line DATA OV black 1 signal ground black 2 not used ST shielding cable shielding Table 5 Communication cable calculators ADP M and ADPMPD M Wires marking in cable CMFM 4D x 1 5 Calculator Puma HT TE or Puma MPD marking colour description TX brown communication line TX RX light blue communication line RX AM black 1 signal Auto Manual OV black 2 signal ground ST shielding cable shielding Table 6 Communication cable calculators Puma HT TE and Puma MPD There are two basic methods of wiring of the communication line between individual AdBlue dispensers and the control unit computer in the filling station a Series connection AdBlue dispensers with PDE ADP M and ADPMPD M calculator the communication cable
30. and by depressing the key lt Shift gt and then the key lt REG gt All nozzles must be locked securely in the boot After the operator mode is recalled value of the first parameter 1s displayed Switching to the next parameters and their items is carried out using the keys lt Next gt and lt gt see sec 3 1 1 The operator mode enables to display but not change the following parameters Description Non resetable totalizers Daily totalizers 04 Cumet meanddate 6 History of failures o Table 9 List of operator mode parameters The operator mode is ended by depressing the key REG on the remote controller The mode is also ended automatically if no key is depressed for 60 seconds 3 1 5 Manager Mode The manager mode is started by pointing the dispenser display by the remote controller at the distance of ca 1 m from the dispenser and by depressing the key lt REG gt All nozzles must be locked securely in the boot After the manager mode is recalled the display shows the prompt for loading the 4 digit access password To have the password secret the loaded digits are displayed as points The manufacturer has set the access password 1111 Example Depress the keys 1 12 1 1 and lt Enter gt After the valid passwotd is loaded the display shows the parameter number 00 by depressing the key Enter you continue by automatic switching t
31. anty and Complaints The contractual warranty is determined the manufacturer warrants for the supplied unit for 2 years or 1 million liters of dispensed medium as a standard The warranty does not cover the consumables e g the tubular discharge lamps When raising possible claims the following data have to be specified e Serial number and name see the rating plate e Precise description of fault and the circumstances under which the fault occurred The claim will not be acknowledged provided that damaged seals ot non petmitted intervention into the unit were established Defects and drawbacks following from incorrect operation inspection and maintenance of the AdBlue dispenser or its functional assemblies are out of scope of the warranty e g the problems caused by presence of water and impurities in the tank and the hydraulic system Check for presence of water and impurities and possible cleaning is necessary in the course of operation 5 6 Accessories e Installation and User Manual Certificate of Quality and Completeness e Certificate of Conformity e controller for operation and programming of the calculator for the AdBlue dispenser s equipped by the PDE el calculator e Foundation frame a special order Spare Part Catalogue This document is specified and distributed for service organization and for servicemen 47 Version 2006 04 07 INSTALLATION AND USER MANUAL Bond NOTES 48 Version
32. arried out to prevent electric shock and to provide flameproofness d Fig 8 No smoking Fig 9 No open fire Fig 10 No mobile phone Technical and technological equipment must comply with the approved conditions which comprise the instructions for safe operation and maintenance as well as solution of emergency states Snow fire extinguishers must be available close to the device in conformity with the fire safety rules When selling and pumping AdBlue the determined procedure has to be adhered to in case of any danger the device must be put out of operation immediately e It is necessary to keep the preset deadlines for regular inspections and checks of the complete installed unit intervention of the persons without relevant competence capability and qualification into the installed technology Regular maintenance and service may be carried out by the authorized service company only e The operator shall keep the device in intact and safe state any defect or unusual phenomenon shall be notified to the service organization immediately in case of danger of delayed intervention the device must be put out of operation 39 Version 2006 04 07 SN INSTALLATION AND USER MANUAL IAISUNQ Send ADELUEO DISPENSERS SHARK 4 2 Putting AdBlue Dispenser into Operation Switching the AdBlue dispenser ON OFF is carried out in the master switchboard of the filling station where AdBlue dispenser feeders are con
33. d reliably Separate channels metal tubes troughs for power and signal cables represent a suitable solution The manufacturer is not liable for the damages caused due to unsuitably designed cable connection 24 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK 3 Basic Functions and Dispenser Setting Setting of the AdBlue dispensers is done by the set of parameters by which functional dispenser parameters can be controlled mode and behaviour of the dispenser in different situations changed materially Values of the parameters can be monitored and changed either by the remote IR controller or by the functional keys placed directly on the calculator or on a simple keyboard being the integral part of the calculator assembly Method of setting of the AdBlue dispenser differs depending on the type of the used calculator placed in the dispenser head The section below describes basic functions and setting for the calculators PDE Puma HT TE Puma MPD ADP M and ADPMPD M 3 1 PDE Calculator The calculator PDE manufactured by the company TATSUNO BENC EUROPE a s is set by the remote IR controller marked PDERT The setting mode setves for monitoring and change of the parameters and provides the following operations e displaying of non tesetable electronic volume and cash amount totalizers of all hoses displaying and reset of daily electronic volume and cash amount totalizers of al
34. depresses the key lt 10 litres gt twice and the key lt 1 litre gt eight times on the pre selection keyboard using the numerical keys 3 operator depresses the control button on the calculator box The el calculator will be reset and the pump el motor placed next to the standby reservoir started 4 The AdBlue dispenser dispenses precisely the preset volume and stops automatically afterwards Note Refueling to the pre selected value can be cancelled by depressing the key lt Zrus gt Cancel prior to start refueling Then another value can be pre selected or the standard refueling may be applied without applying the pre selection 43 Version 2006 04 07 SN INSTALLATION AND USER MANUAL IAISUNQ Send ADELUEO DISPENSERS SHARK 4 3 5 Electromechanical Litre Totalizers The AdBlue dispensers TATSUNO BENC are equipped by electromechanical totalizers as the standard for monitoring of the total fuel volume dispensed by each hose The totalizers are placed on the AdBlue dispenser display One 7 digit totalizer showing the number of full litres pumped by the relevant hose corresponds to each dispensing hose 4 3 6 AdBlue dispenser Display Back lighting Displays of all AdBlue dispenser s are back lighted by SMD LED diodes In case of the PDE calculator intensity of back lighting is controlled as follows the maximum intensity during dispensing and reduced to one third if the data on the display are not changed au
35. dispenser cannot be considered the reason for warranty repairs prior to putting the dispenser into operation Prior to activating inspection of el power distribution and check for correct wiring have to be carried out to prevent electric shock and to provide explosionproofness Each AdBlue dispenser has been tested from the points of its function safety and metrology by the manufacturing plant Delivery of each individual AdBlue dispenser is accompanied by the certification documents which shall be submitted to the competent authorities by the user if asked to do so 0 4 Brief Characteristics of the Used Medium AdBlue 0 4 1 Legislation and SCR technology All vehicles above 3 5 tonnes fall into the class of heavy duty and are subject to new heavy duty regulations These regulations set maximum emission values for PM and NOx Euro and are already implemented where Euro IV and V are to be implemented according to the folowing implementation schedule Legislation Implementation date Scope Euro IV 1 October 2005 New type approval 1 October 2006 All new trucks sold Euro V 1 October 2008 New type approval 1 October 2009 All new trucks sold Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK To be able comply to the above mentioned legislation European truck manufacturers are forced to implement new technologies Selective Catalytic Reduction SCR technology involves
36. disturbances or drop of voltage in peak hours particularly during winter season are very frequent phenomena in our power supply network All phenomena as above can be eliminated by utilization of a correct standby source UPS There are two models of standby source available and suitable for the AdBlue dispenser in our market UPS of line interactive type and UPS of on line type UPS of the line interactive type is enough for stabilization in the filling stations connected to a very stable power supply network without any voltage drop and without any disturbances In other cases the ON LINE type UPS has to be applied Disturbances drops of voltage or failures can result in frequent blocking of the dispensers problems in computer dispenser communication failures of computers data loss etc 23 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUE DISPENSERS SHARK IMPORTAN For trouble free operation of the AdBlue dispensers the signal cables have to be separated thoroughly from the power supply cables Parallel connection of power and signal cables without any separation results in disturbances and undesirable parasite phenomena which may cause problems with AdBlue dispenser control and or even full damage of electronic units inside the dispensers and in the kiosk Therefore any crossing or parallel laying in a single bundle of the signal and power cables has to be prevente
37. e Installation and User Manual to grant the necessary information and instructions facilitating complete and effective installation operation and maintenance of your AdBlue dispensers The Manual worked out by the manufacturer is the integral part of AdBlue dispenser accessories The user is liable fully for use of the Manual any and all operations not described here shall be considered forbidden The operator carrying such operations shall be liable fully for consequences of his her actions The Manual is arranged in individual sections broken down to the sub sections so that each topic may be independent and may correspond to the operating logic learn prepare use maintain The Manual reflects truly the technical state as to the date of AdBlue dispenser sale and cannot be considered non conforming due to follow up changes and updating carried out on the basis of the latest facts MAINTAIN THE MANUAL AND ATTACHED DOCUMENTS FOR THE WHOLE TIME PERIOD OF ADBLUE DISPENSER OPERATION FOR POSSIBLE FUTURE REFERENCES 0 3 Permitted Scope of Use The AdBlue dispensers SHARK 2000 5 AdB ate specified for stationary installation for vehicle refuelling by AdBlue from the tanks in the preset volume The AdBlue dispenser is a complex device which must fulfill a number of demanding functions It is therefore necessary to clean the tanks pipe distributions and carry out check for AdBlue purity dirty filters in the
38. e products can be delivered in any color version at the customer s wish color pursuant to RAL CSN Colorlak scale or a specially prepared color The special color is delivered at the extra charge the level of which depends on the type and shade of the requested color 12 Version 2006 04 07 INSTALLATION AND USER MANUAL NON e SX gt Ee ce o LX NA ox AN CONS KK NX 2S X ON K X JN i x SSS as e cl N x Om X gt S2 N oo 4 iti Pm Fig 1 Figures of AdBlue Dispensers Pos Description Pos Description 1 Input pipe 9 Nozzle Door cover 2 Inler Riser Pipe 10 AdBlue Piston Meter TATSUNO 3 Heating Cable 11 AdBlue Hose with AdBlue Nozzle 4 Spherical Valve 34 12 Data Line Distribution Box 5 Heater with ventilator 13 Power Distribution Box 6 Filter 14 Thermostat 7 Display 15 IR receiver for remote control 8 Base Frame 16 Site Number from LED option 13 Version 2006 04 07 SN INSTALLATION AND USER MANUAL IAISUNQ Sert ADELUEO DISPENSERS SHARK 1 3 Survey of Available Type Models The AdBlue dispensers TATSUNO BEN version SHARK are manufactured in type serie BMP2000 SS Adb variety SHARK with height of 1600mm 1 3 1 Dispenser marking Dispensers series BMP2000 SS AdB are marked as follow BMP201
39. er payment ME Enter or failure lt Next gt Switching to next parameter lt 0 gt Release of both sides whole AdBlue lt Shift gt Swiiching to previous parameter dispenser after payment or failure lt Next gt g op p 1 Preset depressing of corresponding lt gt Switching to next parameter item preset key No 3 10 litres Preset depressing of corresponding TE 2 preset key No 4 1 litre Shift lt gt Switching to previous parameter item 3 Displaying of the latest refilling on the Enter Changed value ofthe displayed display parameter if the operation is permitted Preset depressing of corresponding E Direct switching to the parameter with ae preset key No 1 CZK 100 preset number 55 Preset depressing of corresponding lt REG gt End of selected mode preset key No 2 CZK 10 Cancel Ol preset ene AdBlue CHANGE OF PARAMETER VALUE AND LOADING OF lt 6 gt dispenser side ACCESS preset key No 5 Cancel lt 7 gt Lighting AdBlue dispenser ON lt 0 gt a lt 9 gt Loading Or VAIG ON NE edited switching to the next figure lt 8 gt Displaying of converted CNG gas volume Increase of value of just edited he gt due if the function is activated parameter digit 9 Lighting AdBlue dispenser OFF Shift lt gt Decrease of value of just edited parameter digit lt Next gt Switching to editing of the next parameter digit START OF SETTING MODES lt Shift gt Switc
40. ese company TATSUNO We are speaking about the time tested type of hydraulic unit accepted globally characterized by high reliability and long total service life The system of guards comprises the roof separating grid and register cubicle It covers the hydraulic unit module in the top part and is completed by the masks with the locks The masks accommodate dials with displays The pulse generator TATSUNO is installed on the piston meter The measuring unit consisting of the meter itself filter and controlling electromagnetic valve The pumped medium passed through the filter meter and controlling valve is led into the hose and through the sight glass via the nozzle it is transported into the AdBlue tank of the vehicle The rotary four piston meter is of horizontal design with vertical crankshaft The liquid enters the top meter part and is distributed to each piston by the rotary slide valve fixed on the crankshaft The pistons move under pressure in the graduated cylinders which motion is converted by the crankshaft into the rotary motion one meter shaft revolution 0 5 dm The opto electronic pulse generator registers the motion converts it into el pulses which processed by the electronic register The measured liquid is led away via the rotary slide valve and the crankcase The meter is calibrated by the adjusting handwheel on the graduated cylinder cover The measure error can be eliminated by adjusting the piston stroke When swiveli
41. f necessary trained personnel should apply oxygen or artificial respiration to the person e Call for medical assistance if breathing difficulties continue Ingestion If AdBlue liquid has been ingested e Do NOT induce vomiting e If vomiting occurs lean person forward to maintain open airway and prevent aspiration e Rinse out mouth with water before trying to ingest a comfortable amount e Seek medical advice if large amounts have been ingested or if irritation continues 9 Version 2006 04 07 gt INSTALLATION AND USER MANUAL 0 5 6 Storage of AdBlue AdBlue liquid will crystallise at low temperatures and at elevated temperatures above 50 C it can form biuret and ammonia Always store AdBlue liquid away from sources of heat or fire in AdBlue compatible containers in segregated approved and labelled areas Store away from incompatible materials and avoid contact with strong oxidizers acids alkalies nitrates sodium or calcium hypochlorite which can react with AdBlue to form a potentially explosive mixture Do not store for long periods over six months Ensure the container is securely sealed protected against physical damage andchecked regularly for leaks If a third party tank container for the supply of AdBlue is installed on the service station refer to the manufacturer s recommendations for filling emptying cleaning handling and storage of the tank container unit 0 5 7 Spillage of AdBlue Alt
42. fter locking 8 Blokov n Locked 0 11 Text after display resetting 8 V t me Welcome 0 12 Text after display resetting 8 V s 0 13 Text after display resetting 8 na na 0 14 Text after display resetting 8 stanici 0 15 Text after display resetting 8 0 16 Text after display resetting 8 0 17 Text after display resetting 8 0 18 Text after display resetting 8 0 19 Text after display resetting 8 0 20 Text after resetting time 8 00 00 00 00 00 00 00 00 00 0 21 Text after resetting date 8 01 01 90 01 01 90 01 01 90 0 22 Text of preset for cash amount 2 K Py 1 23 Text of preset for fuel volume 2 Lt Lt Jit 1 Table 18 Table of plant setting of the text messages Sequence of text message editing is as follows 1 Select the parameter No 18 and then select the text message number using the keys lt gt and lt Shift gt lt gt 2 Depress enter key lt Enter gt and load value of parameter 2 editing 3 Move the cursor to the first alphanumeric character which may be edited Now load scrolling the characters forwards or backwards using the keys lt gt and lt Shift gt lt gt When the selected character is displayed depress the key lt Next gt to move to the next character 4 After setting of the message is completed depress lt Enter gt 34 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK ETES 1 Selection of text message number 2 Selection of
43. ger mode Default setting is 1111 31 Version 2006 04 07 d INSTALLATION AND USER MANUAL vx Bent 3 1 5 9 History of Maintenance code 09 The function enables to display codes of the last 10 service remote controllers which the calculator parameters were set by 3 1 5 10 Operating AdBlue Dispenser Mode code 12 The function defines the type of operating AdBlue dispenser mode paremeter Operating AdBlue dispenser mode value 0 Automatic mode 1 Manual with switching to the automatic mode default 2 Manual with switching to the automatic mode and locking 3 Manual stand alone mode 4 Credit internal credit Chipper Table 16 Operating fuel dispenser mode code 12 The parameter may obtain the values in the range from 0 to 4 the value 4 may be set for the credit version PDE only e If value of the parameter equals to 0 the AdBlue dispenser is operated in the pure automatic mode Le it is connected to the master computer console The AdBlue dispenser is controlled by the computer fully AdBlue dispenser release locking setting of fuel prices etc Interrupted communication between the computer and the AdBlue dispenser is subject to the error message 18 which appears on the display e If value of the parameter equals to 1 the AdBlue dispenser is operated in the manual mode see the mode No 3 until it is connected to the master computer Then the comp
44. hing to editing of the previous lt Next gt parameter digit lt Shift gt Commences the operator mode lt Enter gt End of change and loading of a new lt REG gt value Commences the manager mode upon lt Shift gt lt End of change w o loading of a new lt REG gt loading the password Enter gt value Table 8 Description of the keys on the remote PDE calculator controller 26 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK 3 1 2 Setting of Parameters on Dispenser with Volume Display The process of setting is similar to that of the classic three line display only functions of certain keys on the remote controller keyboatd differ Basic principles of setting in the manager and service mode 1 The manager mode is entered by depressing the key lt REG gt The word CODE appears for 1 second on the display Now the password must be loaded After loading the correct password and confirmation by the key lt Enter gt the volume display will shown 0 and the dispenser waits for loading the relevant parameter digit 2 Switching between the parameters by the keys lt Next gt and Shift Next between sub parameters by lt gt and lt Next gt lt gt 3 display value of the parameter on the line Litres volume depress the key lt 1 gt To display value of the parameter on the line Price cash amount depress the key 2 The key Shift
45. hough classified as non hazardous AdBlue liquid when spilt will form crystals and creep If left unattended this will create a slippery surface All spillages of AdBlue liquid must be reported immediately to the Station Manager Avoid breathing vapours and contact with skin and eyes by use of personal protective equipment AdBlue spillage on forecourt e Liberally cover the spillage with sand earth or other inert absorbent material e For larger spills contain the spill with sand or earth and prevent spillage from entering drains surface waterways Do not release into surface water and do not empty into drains e When dry transfer into a suitable container for controlled disposal e If AdBlue is leaked into the drainage system flush liberally with plenty ofwater e Apply prevailing national local regulations for waste disposal AdBlue on dispenser vehicle e Usea soft cloth and water to remove small spillages on the dispenser vehicle RISK OF ELECTRICAL SHOCK NEVER USE A HOSE OR HIGH PRESSURE SPRAY NEAR THE ADBLUE DISPENSER 10 Version 2006 04 07 INSTALLATION AND USER MANUAL gt ADBLUE DISPENSERS SHARK 1 AdBlue Dispensers Tatsuno 1 1 Basic Specifications Dispensed medium 32 5 solution of Urea and water Max flow rate Qmax 40 dm min Min flow rate Qnin 4 dm min Min volume of refueling V min 2 dm Cyclic volume 0 5 dm Maximum operating pressure
46. int exit see Fig 1 2 4 Mechanical AdBlue Dispenser Mounting The AdBlue dispensers are fixed to the special foundation frames by the anchor bolts delivered with the dispenser The foundation frame is out of scope of standard dispenser equipment but can be ordered additionally The foundation frame is seated into the concrete on the island then the front and rear AdBlue dispenser casings are removed the dispenser is placed on the foundation frame and fixed by the fixing screws see Appendix installation pipework and fittings must be manufactured from AdBlue compatible materials Galvanized steel is not suitable 2 5 AdBlue Dispenser Wiring E wiring of AdBlue dispensers TATSUNO BENC requires protection against accidental el shock pursuant to the standard CSN 34 1010 and distribution of relevant el cables to each individual AdBlue dispenser All AdBlue dispensers in the filling station shall be interconnected by the conductor earth electrode and connected to the grounding network The yellow and green conductor section of min 4 mm a special ribbon conductor can be used as the conductor earth electrode The conductor earth electrode must be connected to the central grounding terminal of the AdBlue dispenser placed on the foundation screw M10 marked correspondingly ATTENTION All el cables must have good insulating properties because they ate subject to aggre
47. is led from the point of the control computer in the kiosk service panel into the communication junction box of the first dispenser From hence the cable is led into the junction box of the next dispenser etc until all dispensers in the filling stations are interconnected A single communication line is necessary for interconnection of all dispensers in the station b Star Y connection AdBlue dispensers equipped by the calculator Puma and Puma MPD the communication cable is led from the point of the control computer in the kiosk service panel concentrator star like into the communication junction boxes of all dispensers The number of communication lines necessary for interconnection of all AdBlue dispensers equals to the number of AdBlue dispensers in the filling station Service Line The service line serves for special purposes The line is not necessary for operation of the dispenser but is used if certain dispenser functions need to be controlled remotely or if certain signals have to be led out of the dispenser Necessity of installation of the service line shall always be consulted with specialists of the company TATSUNO BENC EUROPE a s Multi core shielded cables 1 5 mm are recommended for the service line 22 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK 2 5 4 Characteristic Features of Cables Number Rated
48. itable protective aids 2 2 Arrival Transportation Unpacking The customer shall agree the method of dispenser dispatch with the manufacturer Should the transportation be provided by the company TATSUNO BENC EUROPE a s the product will be transported to the agreed place of destination The manufacturer has adequate knowledge of the method of transportation and handling Should the transport be provided by another method selected by the customer the manufacturer shall provide professional loading but is not liable for the method of transportation It is established in general that the AdBlue dispenser must be transported packed always fixed on the frame The dispenser must be fixed on the vehicle and protected from damage guards paints displacement and overturning Handling and transportation must be done in vertical position only the dispenser may not be put on the guards When handling the dispenser only and exclusively high lift trucks may be used TATSUNO BENC EUROPE a s is not liable for possible damage if other handling devices are used 17 Version 2006 04 07 CB N INSTALLATION AND USER MANUAL 2 ADBLUEG DISPENSERS SHARK 2 3 AdBlue Dispenser Installation and Layout TATSUNO BENC AdBlue dispensers do not create hazardous areas potentially explosive atmospheres and therefore there are no zoning diagrams associated with these dispensers Non ATEX certified TATSUNO BENC AdBlue dispensers must NO
49. l hoses e setting of unit product prices manual mode e setting of different functional parameters of the dispenser The setting mode can be recalled on the dispenser by the method below only if the dispenser is at rest completed dispensing all nozzles ate accommodated in the boots There are two setting modes available e Operator mode specified for filling station operators the operator can only read values of electronic totalizers and values of basic dispenser parameters The operator can neither reset nor change their values e Manager mode specified for the filling station manager The manager is authorized both to read the values reset daily totalizers and to set basic operating parameters of the AdBlue dispenser The manager must load the access password to be able to work in the manager mode Fig 4 Remote IR controller PDERT 30 25 Version 2006 04 07 dh INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK 3 1 1 Remote AdBlue Dispenser Control A special remote IR controller must be used for reading dispenser values totalizers change of the dispenser mode or for setting different calculator parameters on the AdBlue dispensers equipped by the PDE calculator The Remote controller keyboard had the following keys and their layout key function key function OPERATING STATE CALCULATOR PARAMETER READING lt Shift gt lt Release of dispenser side aft
50. mounting e switching the calculator ON OFF Setting or monitoring of parameters This operation is reserved to service technicians servicemen only 3 3 Calculators ADP M and ADPMPD M The calculators ADP and ADPMPD produced by the company Beta Control s r o are set using the IR manager keyboard KL MANINF provided with four keys lt gt 02 lt gt and lt gt Functions of the keys are as follows Key Function lt 0 gt Entry into the price setting mode after calculator switching lt gt Selection of figures on the unit price display Selection of the product grade for pricing lt gt Value increase Entry into the mode of totalizer reading AdBlue dispenser at rest Price setting for manual mode Necessary conditions for switching to unit price setting e operating mode MAN parameter No 51 equals to the value 1 e nozzle has not been released since the last actuation of the calculator completed transactions have to be confirmed release through RLS inlets if the parameter No 4 equals to 1 In the MAN mode the unit product prices are set using the manager keyboard KL MANINF or the service keyboard KL SERINF a Mode of unit price b Switching from the c Switching to the lowest setting highest unit product price unit product price order order side A side B Fig 7 Manager keyboard KL M ANINF 36 Version 2006 04 07 INSTALLATION AND USER MANUAL
51. nected Each AdBlue dispenser has three power supply outlets in the master switchboard e feeding of electronic calculator 230V stabilized e feeding of valve switching and heating 230V non stabilized All points above are protected by relevant circuit breakers by which the AdBlue dispensers are switched ON OFF AdBlue dispensers with calculators Puma HT TE and Puma MPD have only the outlet for electronic calculator feeding 230V stabilized in the main switchboard RECOMMENDATION Switching the AdBlue dispenser ON shall be done as follows 1 Switching ON the standby source UPS in the kiosk the green pilot lamp of the UPS goes on 2 Switching ON the 230 V circuit breaker for stabilized feeding of the electronic calculator all display segments tested automatically and values of the last operation of dispensing will be displayed 3 Switching ON the 230 V circuit breaker for non stabilized feeding of valves and switching of submersible AdBlue pump Now the AdBlue dispenser is ready for dispensing refueling 40 Version 2006 04 07 INSTALLATION AND USER MANUAL Y 4 3 Operation of AdBlue Dispenser ATTENTION Operator is liable for normal running of the filling station the operator shall monitor fuel dispensing and if the customer proceeds in the non permitted way the operator must instruct the customer how to handle the dispenser correctly The operator shall also mark the risk zone
52. ng the wheel clockwise the delivered volume will be reduced and vice versa swiveling counterclockwise the delivered volume will be increased One wheel division represents setting by 0 08 of the delivered volume The flow meter accuracy lies in the range of 1 of the delivered volume The electronic register processes pulses from the pulse generator and transmits them to the displays LCD or FP where the dispensed volume price and volume unit price is displayed In case of power failure the data on LCD displays are maintained for min 15 minutes The AdBlue dispenser is equipped by PDE el calculator as a standard Besides the PDE register the calculators Puma HT TE Puma MPD or BetaControl ADP M and ADPMPD M can be used as well The AdBlue dispensers can be operated in the manual mode without the control system or connected via the communication line to the cash desk POS system of the filling station If requested by the customer the AdBlue dispenser can be equipped by volume and price pre selection prepay and or by the thermal correction unit Pre selection All AdBlue dispensers can be equipped by special electromagnetic deceleration valves guaranteeing precise price and AdBlue quantity pre selection and by a clearly arranged 4 key keyboard enabling price or AdBlue pre selection by the customer directly on the AdBlue dispenser Special Color Version In addition to the standard white AdBlue dispenser version th
53. o the parameter No 01 or it is possible to load the parameter number and lt Enter gt for direct switching to the requested parameter After the manager mode is recalled value of the first parameter will be displayed 28 Version 2006 04 07 INSTALLATION AND USER MANUAL p The manager mode enables to display and change set the following parameters _ O 04 Cumenttimeanddate 08 Accesspassword S 09 History of maintenance o Parameters marked by asterisk can be viewed only in the manager mode not set Table 10 List of manager mode parameters The manager mode is ended by depressing the key REG on the remote controller The mode is also ended automatically if no key is depressed for 60 seconds 3 1 5 1 Non resetable totalizers code 01 Electronic totalizers of all hoses meters ate stored in electronic calculator memory These totalizers are non resetable and show how many litres were dispensed by individual hoses item number description 1 volume dispensed by the hose 1 in litres 2 volume dispensed by the hose 2 in litres 9 volume dispensed by the hose 9 in litres H volume dispensed by the hose 10 in litres Table 11 Non resetable totalizers code 01 3 1 5 2 Daily totalizers code 02 The electronic daily totalizers of all hoses meters are stored in electronic calculator memory These totalizers can
54. or resetting of the electronic calculator This parameter has differing data arrangement on the display 32 Version 2006 04 07 INSTALLATION AND USER MANUAL ADBLUEG DISPENSERS SHARK ite ML Error frequency Parameter The first and second line contain the fault code and the frequency rate of the fault in question 3 1 5 12 Current Operating Temperature code 14 The function displays the current temperature measured by the temperature sensor placed on the processor board e line 1 Amount operating calculator temperature e line 2 Litres temperature of the product 1 2 3 or 4 only if the temperature sensors are installed 3 1 5 13 Daily Totalizer Resetting code 15 The function serves for resetting of all daily totalizers registers of the dispensing hoses After setting the parameter value to 1 and after confirmation all totalizers will be reset 3 1 5 14 Operating Check Number code 16 The function serves for displaying of the 6 digit operating check number and for operating code loading e line 1 Amount operating check number 3 1 5 15 Text messages code 18 If the AdBlue dispenser is equipped by the alphanumeric display the function enables to set the text messages which will appear on the alphanumeric display The text messages may be divided into three groups e product names state messages promotion messages Text messages No 1 to No 5 reserved for product names The prod
55. red in such a way as to avoid damage to components or injuries to persons Covers that can be opened such as the calculator housing should be handled with care Ensure that the retaining catch is placed in the correct position to prevent the cover falling onto the head of the service engineer or other persons in the area At unattended service stations every end user should be able to read the User Instructions They should be visible on a notice board or integrated into the DIT and should be sufficiently well lit so that they can be read at night At unattended service stations break away couplings must always be used to reduce the danger caused by a motorist driving off with the nozzle still in the tank WARNING BB THE CONNECTION AND DISCONNECTION OF ELECTRICAL CONNECTIONS MAY ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL AUTHORISED FOR SUCH ACTIVITIES WORK IN DANGEROUS AREAS MUST BE MADE SAFE BY OBSERVING ALL THE NATIONAL SAFETY REQUIREMENTS INFORCE 0 5 4 Personal protective equipment Protective clothing The following clothing should be worn at all times during installation and maintenance procedures e Protective helmet e Protective shoes conductive e Protective gloves and or protective hand cream Ant static clothing e Eye protection Safety equipment for working in hazardous areas The following safety equipment is required for working in hazardous areas e Only spark free tools are permitted for work on dispen
56. required The insides of tanks tubes dome shafts filling shafts change over shafts vessels and dispensers All areas in which AdBlue vapour that is heavier than air can accumulate e g AdBlue separator draining shafts low located rooms cellars excavations pipe trenches etc The ateas around the outlets of tank ventilation pipes especially during the filling phase All areas near dispensers tanker lorries and other vehicles while they are being tanked up and particularly when there is a lack of wind A radius of 1 0 metres around petrol carrying pipes as well as pipes that are not vapour free Silt traps Duties of the employees To ensure optimal accident prevention in our company in addition to general rules applying to worker s protection it is necessary to take into account all the national protection of workers legislation and to actively support all measures which enhance safety standards It is an employee s duty to follow all company directives regarding the prevention of accidents unless such directives can be proved to be unfounded Employees should not follow any instructions that go against safety standards Employees are only permitted to use equipment for its original purpose and this is defined by the company alone If an employee detects equipment that is deficient in terms of safety he shall eliminate this deficiency immediately If such safety rectification is not part of his defined area of activities
57. revent the AdBlue liquid from freezing in the dispenser in temperatures below 0 C 4 3 4 Pre selection Keyboard The AdBlue dispensers TATSUNO BENC can be completed by the pre selection preset keyboard for presetting of the sum or volume directly on the AdBlue dispenser by the customer himself Prior to start refueling the customer can decide how much fuel or for what price he wants to refuel himself If the pre selection keyboards are installed the AdBlue dispenser s have to be equipped by pre selection deceleration valves Example of presetting in CZK 1 The customer comes to the AdBlue dispenser and wishes to refuel himself for CZK 2 The AdBlue dispenser operator releases the nozzle from the dispenser and connects it with the vehicle tank Loads the value 250 depresses the key 100 CZK twice and the key 10 CZK gt five times on the pte selection keyboard using the numerical keys 3 operator depresses the control button on the calculator box The el calculator will be reset and the pump el motor placed next to the standby reservoir started 4 The AdBlue dispenser dispenses precisely the preset sum and stops automatically afterwards Example of presetting in Litres 1 The customer comes to the AdBlue dispenser and wishes to refuel himself by 28 liters of fuel 2 The AdBlue dispenser operator releases the nozzle from the dispenser and connects it with the vehicle tank Loads the value 28
58. sers e Work on bearings is only permitted using the standard workshop tools authorised for this kind of work e use of all electrical tools is strictly prohibited e Only the use of explosion protected work lights is permitted e use of telecommunications equipment in hazardous areas is strictly prohibited Version 2006 04 07 INSTALLATION AND USER MANUAL gt ADBLUE DISPENSERS SHARK Benue Safety instructions The following safety instructions must be adhered to during installation and maintenance procedures e Inhalation of AdBlue vapour must be avoided Suitable precautions must be taken and where necessary respirators used e void direct contact of AdBlue with the skin e Use suitable protective clothing protective gloves and or protective hand cream e Avoid AdBlue spills e No smoking no naked flames are permitted e Long hair and ties can get caught in moving parts Hair must be suitably covered 0 5 5 First Aid procedures Safety Data Sheets for all products should be available in the Service Station These sheets contain important health and safety information relating to the individual product and the specific precautions to be followed in the event of prolonged contact inhalation or consumption AdBlue is a clear liquid with little or no odour making leakages difficult to detect After a period of time the odour may change to a strong ammonia stench Decomposition on heating may produce toxic fumes
59. ssive environment for a long time period For these purposes the manufacturer recommends the cables of CMSM and CMEM types Ends of all cables entering the AdBlue dispenser must be long enough to facilitate installation cable termination in the junction box each cable must end at least 3 m above the ground From the point of applied voltage and function the cables can be broken down to power supply and signal ones Power cables switching of AdBlue submersible pump 19 Version 2006 04 07 gt gt INSTALLATION AND USER MANUAL ADBLUE DISPENSERS SHARK e feeding of calculator switching valves and heating components Signal cables communication lines e complementary service lines pulse outlets etc 2 5 1 Switching of AdBlue submersible pump Switching of AdBlue submersible pump motor is carried out by the 3 core cable CMSM 3B x 1 5 for one nozzle dispensers Cable is connected from the main switchboard in the kiosk to each individual AdBlue dispenser into the junction box see Appendix Marking of conductors in cable CMSM 3C x 1 5 matking color description SL black1 switching phase of submersible pump SN black2 switching voltage max 250V 1A PE green yellow protective conductor Table 1 Cable for Switching of AdBlue submersible pump motor Relay or motor contactor is used in AdBlue dispensers for switching the submersible p
60. tenance of AdBlue dispenser body is carried out by water and or by solution of detergents and available car cosmetic preparations Owner of the AdBlue dispenser shall e Appoint one staff member liable for operation and workability of the AdBlue dispenser e Provide inspections testing repairs and maintenance by the professional method e File documents and operating records e Any and all activities connected with operation and service of the AdBlue dispenser may be carried out only and exclusively by the staff with relevant authorization 45 Version 2006 04 07 SN INSTALLATION AND USER MANUAL 52 ADELUEO DISPENSERS SHARK 5 2 Principles of AdBlue Dispenser Checking Check of equipment tanks pipe distribution lines and AdBlue dispenser s are carried out with the periodicity fixed by the bylaws of the filling station in accordance with the valid regulations Check the AdBlue dispenser hydraulic system for tightness by soap solution Check of machinery equipment e Inspection calibration and official verification of the AdBlue dispenser is carried out by the Czech Institute of Metrology pursuant to valid regulations by the relevant institute abroad Periodicity of measuring device calibration is determined by the Act No 505 1990 Coll e The inspection is preceded by cleaning of the whole device clearing the tanks of dust water and other impurities 5 3 AdBlue Dispenser Error Mess
61. the Manual A Symbols used in the Manual AN Caution El Caution equipment No smoking No open fire No mobile phones The terms used in the Manual which special attention should be paid to Breach of requirements shown under the heading can result in creation of the conditions leading to injury or death of persons or to material damage to property Breach of requirements shown under the heading can lead do injury of persons and or can result in AdBlue dispenser damage ATTENTION The text shown under the heading draws attention to the mandatory and or statutory requirements which assembly and use of the AdBlue dispenser is governed by Breach of these requirements can create dangerous situation and or can result in AdBlue dispenser damage The text shown under the heading draws attention to the assembly procedures processes and operating methods etc which are important for correct assembly and correct AdBlue dispenser operation and which when breached can result in damage failure or bad AdBlue dispenser performance Version 2006 04 07 m INSTALLATION AND USER MANUAL 2 ADBLUE DISPENSERS SHARK 0 2 Read the Manual Thoroughly First Read the relevant parts of the Installation and User Manual prior to start installing or operating the AdBlue dispenser Consider all hazards attentions and notes contained in the Manual The manufacturer has compiled th
62. tion line serves for remote AdBlue dispenser controlling in the so called automatic mode i e the dispenser is controlled remotely by the console or computer The line need not be installed if the dispenser 15 operated in the manual mode only ATTENTION For the communication line at least the four core shielded communication cable of the min cross conductor section of 0 5 mm must be used As the communication line e g the 4 core shielded cable CMFM 4D x 1 5 can be used the cable is led from the operator s workplace in the kiosk into communication junction box of the dispenser witing of communication boxes for individual electronic calculator types see the Appendix Communication Line Wiring The method of wiring of the communication line from the kiosk to the AdBlue dispenser and its connection to the junction box depends on the type of the calculator used in the dispensers and therefore it is necessary to know the type of the calculator to be used in the AdBlue dispensers The electronic calculator PDE of the company TATSUNO BENC EUROPE a s is installed in all dispensers as the standard The calculators ADP and ADPMPD of the company Beta Control or the calculators PUMA HT TE and PUMA MPD of the company Gilbarco Veederoot can be used as a variant If the interface IFSF LON is used for communication with the AdBlue dispensers then connection and wiring of the junction box is identical with connection for the c
63. tomatic switching after expiration of 30 seconds 4 3 7 Signaling Diode SIG on the Display The signaling diode signaling the state of payment blocking and fault of the AdBlue dispenser red The signaling diode SIG is switched to continuous red light if the AdBlue dispenser waits for paying or is in the blocked state and is switched to the blinking red light if the AdBlue dispenser is faulty 4 3 8 Signaling Diode PWR on the Display The orange signaling diode PWR serves for signaling of dispenser calculator feeding If the diode is ON the dispenser calculator is actuated 4 4 End of AdBlue Dispenser Operation RECOMMENDATION Switching AdBlue dispenser off should be carried out as follows 1 Switch OFF 230V circuit breakers for non stabilized feeding of valves and switching of submersible pump 2 Switch OFF 230V circuit breakers for stabilized feeding of electronic calculator 3 Switch OFF the UPS source placed in the kiosk by the switch button on the real panel the green pilot lamp on the UPS source goes off Version 2006 04 07 INSTALLATION AND USER MANUAL Y 5 Maintenance and Service CAUTION Prior to start any maintenance intervention into mechanical hydraulic or electric parts assemblies it is always necessaty to disconnect the AdBlue dispenser from the power supply source and to protect it from re connection reliably DO NOT OPEN THE JUNCTION BOX COVER IF THE ADBLUE DISPENSER
64. uct name with the product number appear on the display immediately after nozzle release prior to display resetting 7 characters may be used for the product name The first character is reserved for the dispensed product number Product names may be set directly on the AdBlue dispenser and from the master computer if enabled by the control system Nozzle telease Start of dispensing Amt E NATURAL Ltrs Text messages No 9 and No 109 are reserved for state messages The said messages relate to the AdBlue dispenser state The message No 9 if permitted will appear on the display immediately after completed refueling after putting the nozzle back before display resetting The said message will take turns on the display with the transaction data e g Payment 100 00 Payment 100 00 The message No 10 if permitted will appear on the display always after the AdBlue dispenser is locked The said message will take turns on the display with the transaction data e g Locked 100 00 Locked 100 00 33 Version 2006 04 07 INSTALLATION AND USER MANUAL e The text messages No 11 to 23 are devoted to the promotion messages The messages No 11 to 19 if permitted will appear on the display always after its resetting The said messages will take turns on the display The text message No 20 if permitted current time Time will appear on the display always
65. ump The switching voltage on the contacts should not exceed the value of 250V and the switching current the value of 1A 2 5 2 Feeding of Electronic Unit and Switching Elements The stabilized feeding of electronic calculator and non stabilized feeding of switching elements is separated in all AdBlue dispensers where the electronic calculator PDE TATSUNO BENC EUROPE a s or the calculators ADP M and ADPMPD M BETA Control s r o ate used Feeding of the calculator and switching circuits is done by the 5 core cable CMSM 5C x 1 5 which is always led from the main switchboard in the kiosk onto the first dispenser module in the junction box wiring of junction boxes see the Appendix C The cable contains stabilized calculator feeding and non stabilized switching element feeding and or auxiliary heating bodies The 3 core cable CMSM 3C x 1 5 Ls Ns PE which is led from the main switchboard in the kiosk always into the junction box of the AdBlue dispenser wiring of junction boxes see the Appendix C is enough for feeding of the calculator in the AdBlue dispensers where the calculators of Puma HT TE or Puma MPD type of the company Gilbarco Veederoot are used Marking of conductors in cable CMSM 5 x 1 5 matking colour description Ns black 2 light blue neutral wire of stabilized calculator feeding Ls brown phase 230V of stabilized calculator feeding Nt light blue neutral wire of switching elements feeding
66. uter is switched automatically to the automatic mode see the mode No 1 Interrupted communication between the computer and the AdBlue dispenser is subject to the error message 18 which appears on the display e If value of the parameter equals to 2 the AdBlue dispenser is operated in the manual mode see the mode No 3 until it is connected to the master computer Then the computer is switched automatically to the automatic mode see the mode No 1 Unlike the mode 2 the AdBlue dispenser is locked after each transaction and has to be unlocked by the magnets or by the remote controller by depressing the key 07 Interrupted communication between the computer and the AdBlue dispenser is subject to the error message E 18 which appears on the display e If value of the parameter equals to 3 the AdBlue dispenser is operated in the pure manual mode The AdBlue dispenser is independent fully cannot be connected to the computer Unit fuel prices may be set by the AdBlue dispenser parameter No 3 e If value of the parameter equals to 4 the AdBlue dispenser is operated in the credit mode The AdBlue dispenser may be switched to this mode only if the AdBlue dispenser is equipped by the credit module PDECRE and the switch cash Credit is in the position ON 3 1 5 11 Error Statistics code 13 The function serves for displaying statistics of the errors which took place on the AdBlue dispenser since the moment of initialization
67. y SSz where is the number 1 or 2 of total quantity of the dispensing nozzles or dispensing hoses z one of the characters D R and L that determinates the dispenser orientation on the station in the car arrival direction D double sided right sided L left sided Addendums After basic type is possible to use following addendums DO Dispenser with volume litres displays only CHIPPER Builded credit automat CHIPPER TA2331 Dispenser is equipped by output signals for device Hectronic Tankautomat TA2331 ADP Used counter type ADP from company BetaControl s r o with protocol Easy Call ADPMPD Used counter type ADPMPD from company BetaControl s r o with protocol Easy Call ADP LON Used counter type ADP from company BetaControl s r o with protocol IFSF LON ADPMPD LON Used counter type ADPMPD from company BetaControl s r o with protocol IFSF LON HT TE Used counter Puma HT TE from company Gilbarco with protocol Logitron PUMA MPD Used counter Puma MPD from company Gilbarco with protocol Logitron PUMA MPD LON Used counter Puma MPD from company Gilbarco Logitron with protocol IFSF LON 1 3 1 AdBlue Dispenser models Typeofdspenser of pumpsites hoses of displays esiin BMP2011 SSL AdB 1 1 1 40 BMP2011SSR AdB i 1 1 40 BMP2012 SSD AdB 2 2 2 40 40 1 3 2 Dimensions amp Weights Version 2006 04