Home
        Ultra Version! - Security
         Contents
1.     If send successful  will return the zone attributes  00 1 01 0 02 2  316 7   6 10Setup the Siren Sound time Default is 180seconds     lf setup successful  will return  Siren ON   xxx   Seconds    E is the identification character of this command   Xxx 000 999  unit is second  3 digits  Default is 180 seconds   E g   if you want to setup the siren sound 60seonds when alarm occur  and password is 1234  then please  send  Tips   Only the zone attribute code that is setup as 0 1 2 3 4 will cause the siren sound while alarm occur  And the siren will       sound about 20 seconds then interrupt about 2 seconds     6 11 Setup the Alarm Delay Time Default is 000second        If setup successful  will returniAlarm Delay   xxx   Seconds    F is the identification character of this command   Xxx 000 999  unit is second  3digits  Default is O00 second   Tips  Only the zone attribute code that is setup as 1 2 3 will delay to cause alarm while alarm occur     6 12Setup the Arm Delay Time Default is 30seconds        SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     If setup successful  will returnAArmed Delay   xx   Seconds    G is the identification character of this command    Xxx 00 99  unit is second  2digits  Default is 30 seconds    Tips    1  Only the zone attribute code setup as 1 2 3 will delay to enter into Arm mode when Arming the SafeBox    2  If the Safebox is armed by remote control  after pressing the Armed Button  and press its SOS button within 2 Seconds  the 
2.     Page 25 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     Relative humidity    10 90   No condensation   GSM frequency  900 1800MHz Default  or 850 1900Mhz  Optional    Communication protocol  GSM PHASE 2 2   include data service    Wired Zones  1  Dry Contact  NC or NO    Wired Port For Arm or Stay  1 Dry Contact  NO    Wired Port For Disarm  1 Dry Contact  NO    Wireless Encode  Learning code  compatibles fixed encode    Wireless Zone  16  can accept one learning code wireless detector in each zone  and accept unlimited  PT2262 2272 fixed code wireless detectors in each zone    Remote Control  3   Wireless Frequency  433Mhz   Wireless Distance  100m in open air    Backup Rechargable Battery  3 7V 900 1200mAH lithium batteries   Net Weight  0 50Kg    9  Maintenance    1  Incase of failure  please contact the distributor or manufacturer    2  Ifthe remote control works  but the SafeBox fails to send SMS texts  switch the power of the SafeBox  to off and switch it on after one minute  Test this system after another minute  or check if the settings  are correct and the GSM Signals are strong enough    3  If the SafeBox sensors work  but it cannot send SMS texts  please change SIM Card to check it    4  If the problem cannot be solved  please contact the distributor or manufacturer     10  Warranty    1  This system is warranted to be free of defects in material and workmanship for one year    2  This warranty does not extend to any defect  malfunc
3.     Serial Number   1 6    A is the identification character of this command    Function 1 Code  1 2 3  It is for alarm receiving attribute setting     1 stands for when alarm occur  the SafeBox will dial as well as send SMS to this number  The SMS  Number Format must be the Same as the Dial Number Format  include or not includes Country code      2 stands for when alarm occur  the SafeBox only send alarm SMS to this number  doesn   t dial     3 stands for when alarm occur  the SafeBox only dial this number  doesn   t sends SMS    Function 2 Code  1 2 3  It is for accessing SafeBox attribute setting     1 stands for when this number dial to the SafeBox  it will be rejected after the first ring  meanwhile  the  SafeBox will be changed to Stay Mode and not return SMS  This is very useful when the user come back  home or office to change the SafeBox to Stay mode with a FREE call from its mobile phone  When the  user leave the home or store or office  dial the SafeBox again  the SafeBox will be changed to away armed  mode and return SMS  to ensure the armed operation is successful    Tips  When any number with this value call in the SafeBox  the SafeBox will change from Stay to Armed or Armed to Stay  if  the SafeBox in Disarmed mode  then the first time call in will change theSafeBox to Stay mode     2 stands for when this number dial to the SafeBox  will be picked up automatically and enter into listen  mode  the user can listen to on site sounds or noise immediately through th
4.     www securitywireless co za  Support  012 654 6209    Page 28 of 28 Ver 1 0    
5.    TT 11111     a  1                   i sae  weWe eit   1 8 8 6  Corea    Switch combination   Remote Control Corresponding Table  Switch Position 2 3     ON    Te Lili    12345678       3  Enter Leaning Mode  Please press the Learn button and then switch on the SafeBox  after the Safebox has been  switched on  it will alert Di sound once  then after enter learning mode  it will alert Di   Di two  sounds  total 3 Di sounds about 5 Seconds   it entered learning mode  then release the  button  The learning Button must be pressed before switching on the SafeBox  and kept in till  the system send a total of 3    Di    sounds   The LED of each zone which is registering a wireless detector or remote control or button will turn  on     Page 12 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer    4         Ultra Version        1  The SafeBox cannot exit the learning mode automatically  the unit must be switched off and on again to  enter the normal mode  The Switch Combinations for each zone must be active by at least one switch to enter  learning mode  and after learning the correct detector into this position  please switch the button back to OFF   otherwise the zone will be in learning mode all the time    2  When learning one detector to the SafeBox  the other wireless detectors must be in OFF status  otherwise  will confuse the learning operation    Learning the Wireless Detector or Remote Control to SafeBox    When the SafeBox is in the learning mode  then switch the corr
6.   Partial Armed At House or Stay  or Disarmed by Remote Control  Wireless  Buttons  Wired Buttons  SMS Commands  Call in with free call  Android Apps and iOS apps     v Supports Android Apps and iPhone iOS apps  quickly to Arm  Disarm  Inquire Status  Switch ON or    OFF Siren  Call in to arm stay  Call in to listen in     v Supports 6 Authorized Numbers  each number can be setup as receive SMS or receive call or both of    them  also  each number can be setup authorized to call in to listen or call in to arm or stay the system     v Supports listen in on site through internal sensitive microphone and call back according to SMS    request     v Automatically send SMS Alert Alarm Message and dial to the authorized numbers when alarm    occurrence     s Learning code  more safe and easy to add new wireless remote keys and wireless detectors     v Supports 16 Wireless Zones  can accept one learning code wireless detector in each zone  and accept    unlimited PT2262 2272 fixed code wireless detectors in each zone     v Supports 1 wired zones Dry Contact Type   the input can be Normal Close NC   Normal Open NO      special for IP Camera alarm output or other wired sensor connection     v Supports verity programmable zone attributes  includes Away normal   At House or Stay  Entrance    Zone  24 Hours Sound Zone  24 Hours Silent Zone  Local Zone  SOS Zone  Door Bell Zone     Page 4 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     Y The SMS Alarm Content 
7.   and return SMS confirmation  Armed     When the SafeBox is in Armed Away  Mode  any authorized number can call in and will change it to  Stay Mode    This function is very useful while you leave or come back to your home     7 3 SMS Commands for Arm Away  or Disarm or Switch On Off Siren     The User can Arm Disarm Switch on or off the siren by sending SMS to the SafeBox  The SMS  Commands are below     The system will carry out the commands immediately  with no delay  after the SafeBox receive this SMS command   7 3 1 Armed Away     XXxxXAA    Example    Return SMS       7 3 2 Disarm    xxxxBB    Example    Return SMS       7 3 3 Switch On the Siren    Page 24 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     XxxxCC Example    Return SMS       7 3 4 Switch OFF the Siren    xxxxDD Example    Return SMS       7 4 Inquiry Status and GSM Module IMEI Code  xxxxEE    Return SMS       7 5 IOS App and Android Apps Instructions    The user can operate the SafeBox by Android Apps and iOS  Both of them are free charge  For Android  Apps  please download from our official website  and download the iKeyPad from Apple Store  The  interface of these tools please see below     GSM Alarm Controller  Set the phone No  first        8  Technical specifications   Rated Voltage  12VDC 2 A  12V 14VDC    Standby Consumption  30 35mA  Not charging battery   Working Consumption  400mA Siren working    Working temperature   10  C  60  C   Storage temperature   20  C  60  C
8.  Hours emergency zones triggered will alarm  all of the other zones  triggered will not alarm   3  Alarm Occurrence  1  When alarm occur  the SafeBox will send out Alarm SMS Content first  then automatically dial the authorized  numbers one by one  if the call is picked up  the SafeBox will stop the siren and enter in to listen mode  cannot  speak  If nobody picked up or rejected  the SafeBox will dial all of the authorized numbers 3 times in cycle then  Stop to dial  Meanwhile  the Safebox will enter to previous status   2  Only the zone attribute code setup as 0 1 2 3 4 will cause the siren sound while alarm occur  And the siren will  sound about 20 seconds then interrupt about 2 seconds  the time according to the setting   3  Once any zone triggered  the corresponding LED will always stay on till Disarm or Restarting the SafeBox     7 1 Operation by Remote Controls       Press the button    k    on the remote key or Press the wireless or wired Arm button  the SafeBox enters  arm status  delay time according to the setting   Under this status  any detector triggered  the SafeBox  will alarm  if answered the call  the siren will stop and can listen in the alarm area by phone    If you use the remote control to arm the SafeBox  you press the Arm Button  then press the SOS button within 2  Seconds  the SafeBox will enter Armed mode immediately  no delay     Press the button    mi    on the remote control  or press the wireless or wired Disarm button  or access  control and RFI
9.  Response Feature  7 Operating Instructions                                       22  7 1Operation by Remote Controls  7 2Armed or Stay WITH a FREE call  7 3SMS Commands for Arm or Disarm or Switch  On Off Siren   7 4lnquiry Status and GSM Module IMEI Code  7 510S App and Android Apps Instructions  8 Technical specifications                                     24  9  Maintenance  10 Warranty  11 Affix Table  Table 1  SafeBox Installation Schedule                   26  Table 2  SafeBox SMS Command List                     27    This handbook has been designed as a guide to the installation and operation of WASMS SafeBox GSM    Alarm amp Dialer     Statements contained in the handbook are general guidelines only and in no way are designed to supersede the    instructions contained with other products     We recommend that the advice of a registered electrician be sought before any Installation work commences     The manufacturer  its employees and distributors  accept no liability for any loss or damage including consequential    damage due to reliance on any material contained in this handbook     The manufacturer  its employees and distributors  accept no liability for GSM Network upgrading or SIMCard       SMS Command List    SMS COMMAND Functions  amp  Actions Very Important   OO A   To arm the SafeBox  in this mode  any detector triggered will alarm  Please fill the  To disarm the SafeBox  in this mode  detector triggered will not alarm  PLS EVENT    To switch ON the Siren
10.  output  Schedule at Page    D   To switch OFF the Siren output 26 before         FE Inquire the SafeBox Status and GSM Module IMEI Code  programming it      The commands should add Password  the format is Password SMS Command  i e   if the password is 1234  then    you can send to arm   1234BB  to disarm  the AA EE must be Caps Lock     Page 2 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     1  Brief introduction    The GSM Alarm  amp  Dialer SafeBox is an Ultra Version of GSM Alarm  includes multi functions and ultra low  cost and high reliability special for Residential areas  business area  commercial area  office  factory    industrial area and other Varity applications  It integrated high performance GSM Module and MCU inside   and with innovative and experienced functions and features to meet the required and potential demands in    the world markets     The user can receive SMS Text and calling from the SafeBox once the alarm occurred immediately  Also   the user can remotely arm or disarm and switch on or off the siren by SMS Commands  or remotely switch  the SafeBox to arm or disarm with free call from mobile phone  or remotely call in the SafeBox to listen in    on site  or send SMS Command to request the SafeBox call back     Moreover  the SafeBox supports Android Apps and iOS  though the Android and iOS Apps  the user can  quickly Arm  Disarm  Inquire Status and Switch ON or OFF Siren  arm or disarm with free call  no need to    progr
11. 8PIN Switch   when the 1  PIN at ON side  it is Stay function  if the 1  PIN at the OFF Side  then it is Arm function   default is at the OFF Side  see below     ON      E       OFF    The connections for wired buttons please see below     x 5 aN    ee   k A    kaw       Arm Button Disarm Button    The connections for Access Control  amp  RFID Card Reader please see below     Page 9 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version              Power Supply  NC GND NO  12V GND Push Access Control amp     RFID Card Reader       Extrance  Button    Using Access Control  amp  RFID    Card Reader to Arm or Disarm a    ule Ty  the SafeBox Connection     J       5 4 Connecting the Siren    The user can connect one 9 12V rated siren  or hooter to the SafeBox   s siren output  once alarm  occur  this output ports will trigger the siren  The positive wire of the siren  gets connected to the  Siren  port  and the negative port of the siren contact to the Siren     port  Generally  the siren wires  are marked with red color and black color  the red color is positive and the black color wire is negative   See below            i        GWEGHESE   i    Ms    Positive       Negative  5 5 Connecting the Rechargeable Backup Battery    The SafeBox is equipped with one rechargeable backup lithium battery that can supply power to the  SafeBox for about 8hours while AC Power goes off  The SafeBox will automatically detect the voltage  Page 10 of 28 Ver 1 0    SafeBox    GS
12. An Advanced  Programmable    Multifunctional  GSM SMS Alarm  amp  Dialer GSM Auto Dialer     Ultra Version  GSM Alarm Panel  WASMS SAFEBOX In The World     User Manual  Ver 1 0    Date Issued  2013 02 01    All rights reserved        SafeBox    GSM SMS Alarm  amp  Dialer    1 Brief introduction  2 Safety Directions  3 Standard Packing list  4 Main Features  5 Installation and Connection Diagram            5  5 1 Inserting the SIMCard  5 2Using the Outlets for wires  5 3Contacting the Wired Sensor CCTV IP Camera  or Other Alarm Panel to the SafeBox  5 4Contacting the Wired Arm or Stay or Disarm  Buttons or Access Control  amp  RFID Card  Reader  5 5Contacting the Siren  5 6Contacting the Backup Battery                10  5  Registering the wireless sensor  5 8Contacting the External GSM Antenna  5 9Contacting the AC DC Power Supply  5 10Switching on off the SafeBox  5 11Mounting the SafeBox  5 12Reset to Factory Default  6 Settings  6 1Setup New Password  6 2Setup Authorized number  6 3lnquiry the Authorized number  6 4Remove the Authorized Number  6 5Modify the wired zone type        Ultra Version     6 6Modify the SMS Alarm Content  6 7Inquiry the SMS Alarm Content Setting  6 8Setup the Zone Attribute  6 9lnquiry the Zone Attribute  6 10Setup the Siren Sound time  6 11Setup the Alarm Delay Time  6 12Setup the Arm Delay Time  6 13Enable to Alert the first Authorized Number    21  6 14Required the SafeBox callback  6 15Setup External Power Status Alert Feature  6 16Setup Siren
13. D Card Reader with authorized access signal  the SafeBox disarms immediately   Under this status  any detector triggered  the SafeBox will not alarm  Except the zone attribute is the  24 Hour Emergency Zones     Page 23 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     Press the button          on the remote control or the wireless or wired Stay button  the SafeBox enters  Stay Partial Armed  status  the zones attribute had been set as outer zone and 24 hours emergency  zone triggered will cause alarm  but the zone attribute had been set as inner zone triggered will not  cause alarm     Press Emergency button  SOS     P on the remote control  The SafeBox will cause emergency alarm   The siren will not sound  but will alert the pre set phone number immediately  The Alarm SMS Content    is Remote Key SOS Help     The Alarm SMS Content for the remote control SOS button cannot be modified     7 2 Armed or Stay WITH a FREE call from authorized phone     The SafeBox supports armed or Stay by a free call from authorized phone  after you setup the  authorized number Function 2 Code as 1  then the user can use this phone number to Arm or Stay the  SafeBox with a free charge call  Please refer to 6 2 Setup Authorized Number to set it up    When the SafeBox is in Disarmed mode  any authorized number can call in and will change it to Stay  mode    When the SafeBox is in Stay Mode  any of the authorized numbers can call in and will change it to  Armed Away  mode
14. M SMS Alarm  amp  Dialer      Ultra Version     of the battery  once the voltage is low  it will charge it automatically  If you do not use the SafeBox for a  long time  please remember to disconnect the backup battery  Please install the battery connector to  the socket  please see below        Must open the backside cover then you can contact the battery  Once the backup battery turn over  the  SafeBox cannot work properly  please contact the external 12VDC to charge it first  If you want to replace the battery by  a new one  please note the specification of the backup battery is  3 7V lithium battery 900  1200mMA  If the Safebox is    not used for a long time  please disconnect the backup battery to save its lifetime   5 6 Registering the wireless sensor  remote control  wireless buttons to the SafeBox    a  After registering the wireless sensor  remote control or wireless buttons  must restart the SafeBox   b  After your registered a wireless sensor or remote control or button to the position  you must switch back the DIP to OFF  Side except the 13t position    c  The package wireless detectors which are registered in the SafeBox already  do not need to be added again    The SafeBox is learning code  it is safe and easy to add new wireless remote keys and wireless   detectors  it supports 3 remote controls and 16 Wireless Zones  it can accept one learning code   wireless detector in each zone  and accept unlimited PT2262 2272 fixed code wireless detectors in   each zone  
15. SafeBox will enter into Armed Mode immediately  will not delay    6 13 Enable to Alert the first Authorized Number when other numbers arm or disarm the  SafeBox Default is Disable     If setup successful  will return Send Operation Code to 1  Numbe    H is the identification character of this command   Tips   f this function is enabled  when the Authorized Number that Function 2 Code 1  can dial in to change the status from  Stay to Arm  call in the SafeBox  will send SMS to the 1st Authorized Number  If any other number armed or disarmed the    SafeBox  it will send SMS to the 1st Authorized number  The SMS content is Armed By   Telephone number or  Disarmed by  Telephone number   Disable this function SMS Command is    6 14 Required the SafeBox callback       If send successful  the SafeBox will call back the user immediately  It is special for the Authorized Number  that Function 2 Code 1  can dial in to change the status from Stay to Arm  to listen on site     6 15 Setup External Power Status Alert Feature Default is 30 minutes        If send successful  will return SMS    M is the identification character of this command    Xx  00 99  Default is 30  Unit is minute   Xx 00  stands for when external AC Power goes off will send SMS to all authorized  numbers or send SMS when AC Power goes on  If setup successful  will return  AC     Power Goes off Send SMS Immediately   Xx 01 99  stands for when external AC Power goes off more than 01 99 minutes will send SMS    Power Goes 
16. The SafeBox is integrated with a variety of programmable zone attributes  includes   Away normal   At House or Stay  Entrance Zone  24 Hours Sound Zone  24 Hours Silent Zone  Local   Zone  SOS Zone  Door Bell Zone  The SMS Alarm Content of each zone is programmable by user   through SMS Commands    Please follow below the step by step instruction to learn the wireless detectors or remote controls or   wireless buttons to the expected zones    1  Writing Installation Schedule  Please write down your schedule in the table below  it will make it clearl what sensor in which zone  and with what attribute  e g   using a wireless door contact for entrance  using the photoelectric  beams for wired zone in outdoor fence  and using a wireless smoke detector for fire alarm and so  on  Please see the Affix table    2  Read the Switch Combination Zone Number Corresponding Table  The SafeBox with fixed switch combination positions for different wireless detectors and wireless  remote controls  please see Switch Positions Zone Number Corresponding Table Structure and  Switch Combination  Remote Control Corresponding Table     Switch combination Zone Number Corresponding Table  Zone Switch Position 4 8        Number   SWTICH4   SWTICHS   SWTICH6   SWTICH7   SWTICH8    Page 11 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     The value in the table for each  zone corresponding the position  of the switch  0 stands for OFF  side  1 stands for ON side     ON     gt  
17. am the SMS commands every time     The SafeBox equips 1 wired inputs for IP Camera Alarm Output  other alarm panel output to transfer alarm  message by SMS over GSM Network     2 Safety Directions    Safe Startup  Do not use SafeBox when using GSM equipment is prohibited or might bring disturbance or  danger     Interference  All wireless equipment might interfere network signals of SafeBox and influence its  performance     Avoid Use at Gas Station  Do not use SafeBox at a gas station  Power off SafeBox when it near fuels or chemicals     Power it off near Blasting Places  Please follow relevant restrictive regulations  Avoid using the device in blasting places        Reasonable Use  Please install the product at suitable places as described in the product documentation   Avoid signal shielded by covering the mainframe        Page 3 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     Use Qualified Maintenance Service  Maintenance can be carried out only by qualified maintainer     3  Standard Packing List    SafeBoxxX1   AC DC Adaptor X1   Remote Control X1   Wireless Door Contact X1   User Manual X1      The Android Apps please contact the distributors  the iKeypad please download from Apple Store for  iPhone    Optional Accessories   Wired Sensors or wireless detectors    PIR Motion Sensor  Glass Break Sensor  Magnetic Window Sensor  Temperature Sensor  Infrared Beam   Fence  Vibration sensor  Siren        4  Main Features    v Supports Away Armed
18. e SafeBox   s microphone     3 stands for this number cannot access the SafeBox by dial in  will be hang up  Nor listen neither change  to Stay or Arm Mode    Telephone Number  authorized number  max  18 characters    E g   if you want to setup 13512345678 as the third authorized number  and the password is 1234  country  code is 0027  when alarm occur this number can receive both SMS and incoming from the SafeBox  when  dial to the SafeBox from this number  can change the SafeBox to Stay or Armed mode  Then you can send    12343A1 1 002713512345678  to the SafeBox  Will return     Tell  Empty  Tel2  Empty  Tel3  002713512345678 1 1    Tel4  Empty  TelS  Empty  Tel6  Empty       6 3 Inquiry the Authorized number    After received this command the SafeBox will return the SMS as abovementioned     Page 19 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     E g   If you want to know the authorized number list  and the password is 1234  then you can send  to check it     6 4 Remove the Authorized Number    Please overwrite it with another number that you wish to change it or removed it by SMS Command     6 5 Modify the wired zone dry contact digital input type  Default is NC     Modify the digital input to NC  Normal Close  type  if the sensor you used with this unit is NC  then you    should set the unit as NC type will return   Zone00 NC         Modify the digital input to NO  Normal Open  type  if the sensor you used with this unit is NO  then you    
19. e back cover off  then  you can see the PCB  See below     Page 5of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     Please remove the screws from here        5 1 Inserting the SIMCard  Important  Make sure to switch off SafeBox before inserting or removing your SIM card     1  Slide the SIM card holder in the direction of    OPEN      etched on the SIM card holder   and then flip    it open        2  Insert the SIM card with its gold contacts facing down and its cut off corner facing out the SIM card    slot  See above photo     3  Slide the SIM card completely into the slot  Make sure the SIM card goes through the 2    guides    on    the SIM card slot   4  Close the SIM card holder and then slide it in the opposite direction of    OPEN    to lock it  See    above photo     5 2 Using the Outlets for wires  The SafeBox reserves 4 outlets for wires at the backside outlets and bottom outlets  The user can  choose the suitable one for different installation requirements  Please use a knife or other tool to  remove the obstacle plastics  Usually  the siren and power supply wires were in one outlets  and the    signal control wires in another outlet to avoid the interference     Page 6 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version        Backside Wires Outlet Bottom Wires Outlet    5 3 Contacting the Wired Sensor or IP Camera or Other Alarm Panel to the SafeBox    The SafeBox equips one dry contact  Normal Close or Normal Open t
20. esponding switch combinations  from OFF to ON one by one  and trigger the wireless detector see Notice   the SafeBox will learn  the code from the wireless detector automatically  When the unit sound a long    Di        sound  it  means the wireless detector was learned to the zone position  please switch the switches back  to OFF  Meanwhile  please switch off the wireless detector  otherwise it will alert a    Di Di    two  sounds after you switch the switch back to OFF  If before switch the switch to OFF then alert by    Di  Di    two sounds  then means the operation failure  please switch them back to OFF then retry  again    Switching the other switch combinations from OFF to ON one by one to learn the wireless  detectors to other zones      a  Remote Control and Wireless Detectors activated method     For remote control  press any key to activate it  no need to press all of them    The wireless door contact can be triggered after the battery is installed    The wireless PIR Motion Detectors can be triggered when switched on    The wireless panic buttons can be triggered by pressing its button    The wireless gas leakage or wireless water leakage and wireless smoke detectors are equipped with a Test  Button  press the Test Button to trigger     The other wireless detectors please reference its user instructions     b  When the wireless PIR Motion detection is setup  please remember to setup the PIR in Test Mode while learning    to the SafeBox  after learned to the SafeBo
21. i    once  and every 10 seconds detects the SIMCARD registering status  and failure will alert by    Di    once till restart or switch off    11  If the communication between the MCU and GSM Module fail  the buzzer will make    DiDi    twice  to warn every 10 seconds till it is switched off or restarted    12  If a SimCard is not installed  the Buzzer will only make one di sound to alert  And will not try and  detect the SIMCard again    13  When alarm occur and in the delay alarm time  the buzzer will alert a    DiDi    sound  once the  delay timeout the buzzer will stop to sound    14  Resetting the SafeBox  it will alert by a 2seconds    Di    sound by the buzzer    15  After you reset or learning remote control or wireless sensors  please remember to restart it   otherwise  it will not work properly    16  The SMS commands that you will certainly use in the GSM Alarm  amp  Dialer SafeBox are the  following     6 1 Setup New Password       Page 18 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     if successful  the unit will return  new password  This is the New Password  please remember it  carefully  The password is 4digits     For example  the original password is 1234  you want change it to 6666  then you can send the command    below   1234P6666    6 2 Setup Authorized number lf you GSM Operator use different number format for SMS and Dial out     then please see Notice 6  must setup as  include country code and not include country code     
22. n     6  Some popular wireless detectors    i    an an an omn   n R    m       o            PIR Motion Detector Dual Element PIR Motion Detector Ceiling PIR Motion Detector Door Contact    a    1       mn p         j    Door Contact Garage Door Contact Photoelectric Beams Detector Microwave Dual PIR Detector       Page 14 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version          ly    L   m  lt a     gt   RF Transmitt   S       ee OS aS ansmitter  oeo                                  asd   K  4  hp  kA    ANAEETI   G  1      gt   Wiha         amp     Gas Leakage Detector Smoke Detector            w    amp        Necklace Waterproof Panic Button Emergency Button Wireless Signal Repeater  5 7 Connecting the External GSM Antenna    The SafeBox is equipped with an internal GSM Antenna  usually the GSM Signal is good enough to  register the gsm network properly  But if the GSM signal is not good enough  please replace it by external  GSM Antenna from your distributors or agents  Or take the external GSM Antenna and its connectors to  ask any electronic engineer to replace it  please don   t replace it by yourself  otherwise the SafeBox may  get damaged  The enclosure reserved one hole at the top side  please remove it and fix the external GSM  Antenna through this hole     5 8 Connecting the AC DC Power Supply    Please connect the  12VDC power supplyto the SafeBox  the Positive of the  12VDC connect to the  PWR   the negative of the 12VDC please contact t
23. o PWR     Generally  the red color from the AC DC  Adaptor is Positive  and the black color is negative  The AC DC Adaptor is 12V1A or 12V2A  see below     Page 15 0f 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     ALA        12VDC   12VDC    5 9 Switching on off the SafeBox    After finishing all of the connections  please connect the AC DC Adaptor to external AC Power socket  and  switch the PSW Switch to ON  to switch on the SafeBox  See below        5 10 Mounting the SafeBox    The SafeBox should be installed in a place where the intruders cannot discover it  And the GSM Signal  coverage is good  Also  the user can see the LED display to know what happened and what is the status of  the SafeBox     5 11 Reset the SafeBox to Factory Default    The SafeBox can be reset to the factory default by following this operation  Switch off the SafeBox  then  press the Reset Button  See below   Switch on the SafeBox  about 3Seconds later  the SafeBox will make     Di Di    2 sounds  then release the RESET button  then the reset operation is successful  And please  restart the SafeBox     Page 16 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version        After this operation  all the registered wireless detectors and wireless panic buttons and Remote Controls  will be removed from the SafeBox  and all of the settings will be reset to the factory default     6  Settings    The SafeBox is an advanced multifunctional programmable controlle
24. of each zone is programmable by user through SMS Commands     v Supports 3 Remote Keys  each Remote Key includes one SOS Panic Button for emergency condition    to ask for help     v Supports Armed delay to give enough time to leave the home  the delay time is programmable by user     v Supports Alarm Delay to give enough time to Disarm it when you come back home  the delay time is    programmable by user     v Equips one siren output for sounding while alarm occurrence to warning     Y The external AC power failure  amp  recovery alert function supports 2 optional  Immediately Send SMS to    user  after 30 minutes if not recovery then send SMS to user     v Standby internal large capacity rechargeable battery which can standby upto 8hours after AC Power    failure  also can provide power to wired siren after AC power failure     v Secure   Using caller ID for identification  unknown callers are ignored   v Supports Password to increase the security of the whole system   v Based on the GSM communication network  no distance limitation     5  Installation and Connection Diagram    Tips    a  The backup battery was disconnected  please contact it first according to 5 6    b  After the SafeBox was switched on  it will indicate by a long Di sound  all zones    LED will turn on once   and the zones which registered wireless sensors  wireless remote control or wireless buttons will turn on  once again    In the backside of the SafeBox  please remove all of the 3 screws  and take th
25. off 01 99minutes   to all authorized numbers or send SMS IAC Power Goes ON when AC    Power goes on  If the AC Power goes off less than 01 99 minutes then goes on  will not send SMS  If  setup successful  will return AC Power Goes off Send SMS After 01 99minutes     6 16Setup Siren Response Feature to Arm Operation    Xx  ON or xx OFF  Default is off   Xx ON  stands for when armed the SafeBox by remote control successful  the siren will sound 2seconds     Page 22 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     If setup successful  will return  Set Ok     Xx OFF  stands for when armed the SafeBox by remote control successful  the siren will NOT sound  If    setup successful  will return  Set Ok     if armed or disarmed by phone call or SMS  the siren will not make sounds to response   7  Operating Instructions    1  The user can arm disarm Stay  Partial armed  by Remote Control  Wired Button  Wireless Button  Access Control  System or RFID Card Reader  Dial in  and  SMS  the user can also switch on or off the Siren by SMS Commands   2  Mode explanation  Armed  Away  In this mode  any detector triggered will alarm  It is used for away arm to activate all sensors   Stay  Partial armed  at home  in this mode  only the outer zones and emergency zones triggered will alarm  the  inner zones triggered will not alarm  It is used for partial armed  e g   some people at home  and need to monitoring  the outdoor security   Disarmed  No sensors  except the 24
26. preset numbers and dial the preset number and trigger the siren  This is very useful for  lots of applications that need IP Camera and Alarm notification immediately by SMS or Dialing   The connection is below     DIN GND       1A 2B is Alarm Output from IP Camera  DIN and GND are Alarm Input in SafeBox         VIDEO OUT    we  oe    VIDEO IN SafeBox       DIN GND       The DYR with Alarm Output NC NO   contact to DIN and GND in the SafeBox     3  Connecting the other alarm panel output to SafeBox    The user can connect the other Alarm panel   s digital output to the SafeBox   s Digital Input as a  wired detector  so the user can update its alarm panel as GSM SMS Alarm     Connecting Wired Arm or Stay or Disarm Buttons or Access Control  amp  RFID Card Reader  The SafeBox is equipped with ports for Arm  Disarmed by wired buttons or RFID Card Reader for user  convenience  The user can install a NO type button to arm at the entrance  and through a separate  button to disarm  Or in office and store and shop where many people with RFID card  then can  connect the RFID Card Reader output signal to the disarm port  so once somebody open the gate  will  automatically disarm it by RFID Card Reader  no need any other operations    The Button or output signal from Access Control or RFID Card Reader must be NO type   Page 8 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     The user can setup the Arm port as Arm function or Stay function by the 1  PIN of the 
27. ps Lock     Function Description SMS Command Format    Arm Away  1234AA  Password is 1234   Disarm 1234BB  Password is 1234   Switch On The Siren 1234CC  Password is 1234   Switch OFF the Siren 1234DD  Password is 1234   Inquiry Status GSM Signal  IMEI 1234EE  Password is 1234   Setup New Password 1234P6666     owd Serial Number A Function 1 Code   Function 2  code  Telephone Number    See 6 2   Inquiry the Authorized number owd A      Remove Authorized Number pwd SerialNumber A    Modify wired zone type as NC pwd NC   Default is NC  Modify wired zone type as NO owd NO      wd B ZoneNumber    SMS   1234B05 intruder  Modify the SMS Alarm Content ee    Alarm Content   breaking the windows     Inquiry the SMS Alarm Content owd B Zonenumber   1234B01     Setup the Zone Attribute owd D Zonenumber   Attribute Code    See 6 8     Inquiry the Zone Attribute owd D    Setup the Siren Sound time Owd E xxx   1234E060   Default 180S   Setup the Alarm Delay Time OWd F Xxx   1234F999    Default 000S     Setup the Arm Delay Time owd G xx   1234G09    Default  30S   Enable Alert the 1  Authorized No    pwd H     Disable Alert the 1  Authorized No    pwd J   Default  Required to callback owd K     AC Power Goes OFF Alert at once   pwd M 00      AC Power Goes OFF Alert after l l  owd M xx   Default is 30minutes  01 99 minutes    siren Response to Arm Operation pwd ON    Default    Siren NOT R toA  iren   esponse to Arm pwd OFF    Operation    The End     Setup Authorized number    4      a    7
28. r  The user can program it by SMS  Commands for various application requirements     1  The default Password is  1234    2  All the settings are through SMS commands  please edit the below SMS commands in your cell  phone  then send to the SafeBox   Tips  The SafeBox cannot support a PIN Code Protected  SIMCard  Please ensure you have disabled the PIN Code of the SiMCard  otherwise it cannot  register the GSM Network successfully     3  You can program the GSM Alarm  amp  Dialer SafeBox with SMS commands using your phone  It is  safe to do so because in addition to the fact that other people may not know the number of the  SIM inserted in it  we also use a Password that makes it impossible for anybody  who doesn t  know it  to access the system by chance    4  Remember that commands must be  CAPITAL LETTERS  It is PWD not pwd  CAP not Cap etc   Don t add spaces or any other character    5  The pwd in the commands means the password    6  Some GSM operators use different SMS parameters  the units can   t return the SMS confirmation  as normal  It is not a product problem  Also  you can try to add the country code before the  number  because every GSM Operator will automatically add the country code while sending a  SMS or receive SMS or dialing  the format is not the same for dial and SMS  If some functions do  not work  then please setup the country code or remove country code for different functions  see  the below settings     Page 17 of 28 Ver 1 0    SafeBox    GSM SMS Ala
29. rm  amp  Dialer      Ultra Version     For example     In South Africa  the country code is  0027   or  27      The user cell phone number is 13500001111  and has been assigned as a SMS Alert number  the simcard  number in the panel is  13512345678     Problem 1  Alarm but the user hasn   t received the SMS Alert     Solution  Please add the country code when you setup the 13500001111 as the SMS Alert number     002713500001111  or 2713500001111  instead of  13500001111    Problem 2  The user number can receive the SMS Alert message from alarm panel  but the alarm panel can  not receive the commands from the user number     Solution  Please add country code to the simcard number in the alarm panel  Send sms command as    002713512345678 or  2713512345678 instead of  13512345678        7  Please write down the setting list on a paper for review in future  please see the affix table at the  last page  and tear down from this instruction for review    8  If the command is incorrect  the SafeBox will return   Or other warning message  So please check the Command  or check the  input is in ENGLISH INPUT METHOD and CAPS LOCK  If the password is incorrect it will not  return any SMS    9  When power on the SafeBox  will alert Di sound once  and all zones    LED will turn on once  then  the LED which registered wireless sensor  will turn on once again    10  If after more than 2 minutes the GSM Simcard still try to register the GSM Network  it is a failure   the buzzer will make    D
30. should set the unit as NO type  will return  Zone00 NO     6 6 Modify the SMS Alarm Content       If setup successful  will return the SMS Alarm Content    B is the identification character of this command    Zone Number 00 16  00 stands for the wired zone  01 16 stands for the 16 wireless zones    SMS Alarm Content  When alarm occurrence  the SafeBox will send the SMS Alarm Content to the  authorized numbers by SMS  Max  40 characters and cannot be empty  otherwise the SafeBox will return      SMS Alarm Content cannot be set as empty     E g   if you want to receive SMS Alarm content of the wireless zone 05 is intruder breaking the windows     and password is 1234  then you can send SMS  1234B05 intruder breaking the windows      6 7 Inquiry the SMS Alarm Content Setting    If setup successful  will return the zone number   s SMS Alarm Content     6 8 Setup the Zone Attribute       If setup successful  will return the zone number s Attribute code    D is the identification character of this command    Zone Number 00 16  00 stands for the wired zone  01 16 stands for the 16 wireless zones    Attribute Code 0 9  stands for how will the SafeBox perform when this zone is activated     0  stands for entrance  when the Safebox is armed  this zone will delay 30 seconds before entering  Armed mode  for leaving the home or office  When the user comes back from home or office  the unit  will delay 20 seconds prior to alarm  in order for the user to change it to Stay or Disarm     1  s
31. tands for outer zones   in Armed or Stay mode  when triggered will cause alarm     Page 20 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version      2  stands for inner zones  in Stay mode if triggered will not cause alarm  in Armed mode  if triggered will  cause alarm     3  stands for spot alarm zone  in Stay mode if triggered only cause the siren to sound  Neither dial out nor  send SMS out  in Armed mode if triggered will cause alarm     4  stands for 24hours emergency zone with sounds  In any mode if triggered will cause alarm  immediately with siren sounds     5  stands for 24hours emergency silent zone  In any mode if triggered will cause alarm immediately  the  siren will not sound     6  stands for Armed Button  trigged it to make the SafeBox change to Arm Mode     7  Stands for Stay Button  triggered it to make the SafeBox change to Stay Mode     8  stands for Disarm Button  triggered it to make the SafeBox change to Disarm mode     9  stands for door bell button  triggered it to cause the buzzer to sound 8times    Tips    1  When the attribute code setup as 6 7 8 9  the siren will not sound    2  More than one zone attribute can be setup in one SMS Command but don   t exceed the SMS character  limitation   e g   if want to setup the attributes of wired zone  01 wireless zone  O2wireless zone  03  wireless zones  08 wireless zone  the password is 1234  then please send    1234D00 0 D01 1 D02 4 D03 6 D08 9     6 9 Inquiry the Zone Attribute      
32. tion or failure caused by abuse or misuse by the  Operating Instructions  In no event shall the manufacturer be liable for any alarm system altered by  purchasers     11  Affix Table    Table 1  SafeBox Installation Schedule  Before installing the Safebox  please write down the installation plan first  it is very useful for saving your  test and installation time  After installed successful  then tear down this Schedule for review in future     Page 26 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     SafeBox Installation Schedule    Pa Default Value of Zones User Defined Value of Zones       Attr  SMS Alarm Content Attr  Souci aeelee     wiredzonealarm    2 ff  of entenent   o       wesma   2   C   2 fT  a wesa  2   05   weksszoe samt  2  wks Zone 6am    2  Pts zoe 7a    2  Wels zone Barat   2  wres ant   2    Wireless Zone 11 Spot  Alarm     Smoke Detector Alarm     Water Leakage Alarm  Es    07  10  11    Gas Leakage Alarm   Panic Help Alarm   Emergency Silent Alarm     SafeBox Authorized Number Schedule    2   2   1   1   3   12 A  13 4  14 4  15 4  6 5    1    SIMCard Number in the SafeBox     Authorized Type  Phone Number Alert when Alarm Occurrence Access the SafeBox  SMS amp Call Stay Arm          Serial  Number    Notice  Please mark V if for enable and X for disable        Page 27 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer     Ultra Version     Table 2  SafeBox Program and Operation SMS Command List  SafeBox SMS Command List Ca
33. x  then please change PIN to Normal Mode by chaninge the Black  PIN Jumpers on the PCB     c  The differences of PIR Motion Curtain Motion and Ceiling motion detector are the detection direction areas   d  When the wireless Detectors is PT2262 fixed IC code  please setup its wireless code by using some Jumpers to    Page 13 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     configure it randomly  recommend 4 6 jumpers  see below    1  Removing the back cover carefully    2  Locate the IC boards black jumpers  labeled AO A7 and DO D3  please see below figure    3  Configured the AO A7 and DO D3 different from each wireless detector  If configured the AO A7 and DO D3 are  the same  the system will treat them as the same one sensor  So if you want to add more than one wireless  detector to any zone  please configure the jumpers to be the same in each of the wireless detectors    4  Also  please check the Resistors value is 3 3M Ohm  there   re 3 Jumpers  1 5M  3 3M  and 4 7M  if you select  incorrect value  the wireless distance is usually very short or cannot learn to the SafeBox     L N 0 H N 1  L N H 2    Pr    SL a p     5  Removing wireless accessories     After learned the wireless accessories to the SafeBox  it can be replaced by learning a new  wireless detector to its position  If you want to remove the wireless detector in a specified  position  then please reset to remove all wireless detectors and re learn the other wireless  detectors agai
34. ype  digital input port  the user  can connect the IP Camera or CCTV DVR or wired detector or other alarm panel to this port  When the  digital input triggered by IP Camera or CCTV DVR or wired detectors or other alarm panel  it will alarm     1  Connecting the wired Detector to SafeBox    The wired detector has two wires  please contact one of them to the DIN port  another contact to  the GND port  And setup the Digital input to be the correct NC or NO type by SMS Commands    Tips  if you don   t know the NC or NO type of the Detector  please try to change the setting to NC  or NO type by SMS Commands to after you finished connections         Wired Scroll Door Contact    If you need to contact more than one wired sensor to the SafeBox  please ensure all of the wired  detectors are the same output type  Normal Close or Normal Open Types   when any one of these  detectors are triggered  the SafeBox will alarm    lf the wired detectors are NC type  then the connection must be in series  see below         NO Type  Connection    NC Type Connection       if the wired detectors are NO type  then the connection must be in parallel  see above     Page 7 of 28 Ver 1 0    SafeBox    GSM SMS Alarm  amp  Dialer      Ultra Version     2  Contacting the IP Camera or CCTV DVR to SafeBox    The user can connect the IP Camera or CCTV DVR Alarm Output to the SafeBox   s digital inout as  a wired detector  once the IP camera detect intrusion or CCTV DVR alarm  the SafeBox will send  SMS to the 
    