Home
        Spark Driver Module Kit User`s Manual
         Contents
1.     Drivven  Inc  2009     Spark Driver Module Kit User s Manual   D000012   Rev F 14    Drivven  Inc  Spark Driver Module Kit    location  Finally  specify an appropriate name for the module  which will later appear in  the FPGA I O nodes in the FPGA block diagram  Having meaningful module names is  important for preventing coding mistakes    13  After adding a module to the project  a folder will automatically be added to the project  having the same module name given in the module configuration dialog  The folder will  contain the FPGA I O pins for the module slot  These I O pins can be selected in the  block diagram when connecting the module VI PinInput and PinOutput clusters to FPGA  I O nodes  The example application  discussed below  should be consulted for further  details about connecting the PinInput and PinOutput clusters to FPGA I O nodes  Within  the example projects  notice the FPGA I O node elements having module name prefixes    14  Some Drivven modules can be automatically recognized by LabVIEW when adding cRIO  modules to the project  However  Drivven does not recommend using this feature  because the module names  which are automatically assigned  are not meaningful   Mod1  Mod2  etc  and can lead to coding mistakes when wiring the Drivven FPGA VIs to  the I O nodes  Adding the modules to the project manually  as described above  is still  the recommended method        Driven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 15    Drivve
2.   Module over temperature protection   gt  External power supply of 6 32V    O O 100  0       Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 3    Drivven  Inc  Spark Driver Module Kit    Pinout           BATT      SPK1      SPK2      SPK3     sSPK4         SPK5         SPK6         SPK7        SPKS    2  3  4  5  6  Li  8  9           GND       Hardware    The Spark Driver Module Kit provides eight inductive type ignition coil drivers in a National  Instruments CompactRIO module     Revision Notes    Revision F of the Spark Driver Module Kit incorporates firmware and software changes that are  not compatible with previous versions of the module  Software for revision F will not recognize  modules of previous versions  Be sure to use the RevF FPGA VIs with the RevF module        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 4    Drivven  Inc  Spark Driver Module Kit    Powering the Module    The Spark Driver module requires power from two different sources     One source is from the CompactRIO backplane male high density D Sub 15 pin  HD15   connector which mates with the module   s female HD15 connector  This power source provides a  regulated 5 volts and ground to various digital logic functions within the module  The  CompactRIO 5V source is active whenever the CompactRIO or R Series Expansion Chassis is  properly powered  The module should only be powered at the HD15 connector by plugging it into  a CompactRIO or
3.   SparkEnable booleans    4  If Dwell is modified during the main spark pulse to a value greater than the existing  dwell  then the pulse is continued only until EndPosition  unless CutoffPosition or  MAX_DWELL of 5 msec is encountered first     Modifications to EndPosition    EndPosition can be modified at any time  However  the value must not be advanced by more  than 45 CAD within a single engine cycle  This value is referred to as the History Window  The  spark VIs continually check the requested EndPosition with respect to the current crank position   If the EndPosition is modified by the CPU to a position in the past  the spark VIs use the History  Window to determine whether a late spark pulse should be started    1  For example  let s assume that a spark pulse is scheduled for an EndPosition of  200 Absolute CAD  ACAD  and a dwell time of 40 000 ticks  1 0 msec   such that  the spark pulse is scheduled to turn on at 150 ACAD  Let s also assume that the  CurrentPosition of the EPT VI is 140 ACAD when the CPU modifies EndPosition to  180 ACAD  which means that the required start of the pulse is now 130 ACAD   This new start is in the recent past by 10 CAD  Since this is less than the 45 CAD  History Window  then the spark VI will immediately start the spark pulse even  though it is late  The dwell will be turned off at EndPosition as long as MinDwell is  satisfied    2  As another example  let s assume that a spark pulse is scheduled for an  EndPosition of 200 ACAD and 
4.   spark_vt_8mux1_revf vi  This VI is for interfacing directly with the Drivven Spark Driver module and for providing a control  interface to the LabVIEW RT level     Number of Spark Cores Implemented   1  2  3  4 0  Number of Channels Operated   1  2  3  4  6  or 8     The FPGA VI must be placed within a Single Cycle Loop  SCL  of a LabVIEW FPGA block  diagram  The SCL must execute at the default clock rate of 40 MHz     The FPGA VI requires a pre synthesized netlist file having a matching name and an extension of   ngc  The netlist file must be located in the same directory as the matching VI  The installer will  place this file in the LabVIEW addons directory along with the FPGA VI     The Pininput and PinOutput clusters are wired to LabVIEW FPGA I O nodes which are configured  for acRIO controller chassis or a cCRIO R Series expansion chassis  Refer to the LabVIEW  FPGA documentation for details about creating and configuring FPGA I O nodes     Connector Pane  SparkControl  FuelSparkSupervisor  SparkPinInput      SparkData  SparkPinCiutput       Controls and Indicators          SparkControl This cluster contains controls for enabling and configuring the spark  channels      HH SparkEnableX When TRUE  the spark command is enabled  When FALSE   default   the spark command is disabled     EndPositionX Spark pulses are generated with a trailing edge coinciding with  EndPosition  The length of the pulse will be according to Dwell  The leading  edge will be determined by the cur
5.  R Series Expansion Chassis  The module   s HD15 connector should not be  connected to any other device     Another required power connection is at the external screw terminal connector  The terminals are  labeled BATT  0  and GND  9   Typical power sources will be from automotive 12V or 24V  battery systems  However  the module can accept power from a range of 6V to 32V  With no  actuators connected  the module requires up to 100mA from the external supply  However  the  external supply must be capable of powering the actuators connected to the module  Therefore a  battery or power supply capable of 7A may be necessary under full load     The external battery power ground is completely isolated  within the module  from the  CompactRIO 5V supply ground  However  the external battery ground and the CompactRIO  ground may be connected externally     The module will not be recognized by software without both power supplies active     Warning  The external battery supply input terminals are not reverse voltage polarity  protected  Connecting power to the module in reverse polarity will damage the module   This event is not covered by the warranty  Please refer to the  DrivvenReverseBatteryNotice pdf document  available on the website  for a recommended  solution for protecting a system from reverse battery polarity        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 5    Drivven  Inc  Spark Driver Module Kit    Platform Compatibility    CompactRIO 
6.  dwell  Each channel is capable of driving to a peak of 7  amps  During operation  a channel is turned on  low side switch to ground   sinking current  through the primary winding of an ignition coil  thus storing magnetic energy in the coil  When the  channel is switched off  the magnetic field of the primary quickly collapses causing the voltage  across the secondary winding to spike  delivering a spark across the gap of a connected spark  plug  The spark must find a path to battery ground via ground connection with the spark plug  body  The engine cylinder head will provide a ground path for the threaded spark plug body and  must have a ground connection back to battery     The Spark Driver Module Kit is not intended to control  smart    ignition coils with built in driver or  igniter circuits  Smart coils require digital commands  whereas the Drivven Spark Driver Module  contains low side switches for sinking current through a standard ignition coil primary winding    For commanding smart coils  consider the Drivven Engine Synchronous TTL Output Module Kit     The amount of time that the driver channel is turned on  or dwell time  will  in part  determine the  voltage that can be achieved at the spark plug gap  The gap length also determines the spark  voltage  The dwell time required to achieve certain spark energy will vary with the characteristics  of the ignition coil  For example  the dwell time required to achieve 20 kvolts at the spark gap  using different coils co
7.  handling any of these parts  Receiving an automotive ignition spark at any voltage  can be very painful  Persons with medical devices or heart conditions should not be  involved with testing or installing ignition systems     Use a current probe to monitor the current through the primary while conducting dwell tests  Most  passenger car ignition coils require 3 7 peak amps to achieve a consistent spark  If the coil  manufacturer s recommended current rating is not known  then it is good to use the current probe  to know if excessive current is required to achieve spark  If more than 8 amps are required to  achieve spark then the module will not be able to drive the coil at higher engine speeds without  overheating  The module is fuse protected for a total current of 10 amps     Prepare an application for simulating a running engine using your EPT VI  There is an example  application included with the Spark Driver Module Kit for this purpose     The Spark Driver Module should be powered externally from the same power supply  battery   voltage which feeds the high side of the ignition coil s   Connect one side of the coil primary to  battery voltage and be sure to use an automotive fuse  7 5A  in this connection  We are all  prone to making mistakes with connections and software settings  It is better to blow an external  fuse than the fuse within the module  Connect the other side  low side  of the coil primary to the  spark driver module channel that you will be using for te
8.  lookup Vis or CalVIEW table lookup Vis  Do not use a fixed dwell time in your  application if you expect the battery voltage to vary  This could lead to weak sparks or blowing    the module fuse        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F    Drivven  Inc  Spark Driver Module Kit    Ignition coil primaries should be wired to the Spark Driver Module according to Figure 3  An  automotive 7 5A fuse is recommended to be used in series with the high sides of the primaries     Spark Module Connector    Notes     3          N             N        Battery or  Power Supply   12V Typical     gt 10A Peak                OO JO UL ONO    M  El Spark Plug    E    Spark Plug    Figure 3  Connecting ignition coils to the driver module     Use 18AWG or larger diameter wire    Spark plug body must have ground path back to battery    A CompactRIO controller may be powered by the same power source or by an isolated  power source  If the cRIO controller is powered by the same battery and this battery is  used for cranking the engine  then it is possible that the battery voltage will drop below  9V during cranking  causing the cRIO controller to reset  This can be prevented by using  a small backup battery and a diode pack for the cRIO controller  Please contact Drivven  for recommended parts and connections    When using wasted spark ignition coils which have two secondary connections per  primary  Drivven recommends connecting two spark driver channels to e
9. AT per engine cycle would be 2 60 128 15360     MAX_CAT  Maximum Crank Angle Ticks per engine cycle        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 16    Drivven  Inc  Spark Driver Module Kit    Table 1 shows a list of all spark VIs included in this kit   Table 1  Spark VI Configurations    Number of Spark Outputs    VI Name  WasteSpark   FALSE        k    spark_vt_1mux1_revx vi  spark_vt_1mux2_ revx vi  spark_vt_2mux1_ revx vi  spark_vt_1mux4_ revx vi  spark_vt_2mux2_ revx vi  spark_vt_4mux1_ revx vi  spark_vt_1mux6_ revx vi  spark_vt_2mux3_ revx vi  spark_vt_3mux2_ revx vi  spark_vt_6muxl1_ revx vi  spark_vt_1mux8_ revx vi  spark_vt_2mux4_ revx vi    spark_vt_4mux2_ revx vi    CO  CO  Od  ODI DI ODI  oO   JoO   2  2  2aj  nDn n          spark_vt_8mux1_ revx vi    As can be seen from Table 1  there are multiple Vis that support two  four  six and eight spark  driver outputs  For example  if an engine control system was being prototyped for an eight  cylinder engine with one coil per spark plug  then there are four different Vls to choose from  which support eight spark outputs  One of those VIs internally contains eight individual spark  cores  each controlling a single output  Another VI internally contains four spark cores  each  multiplexed to control two outputs  Another VI internally contains two spark cores  each  multiplexed to control four outputs  Finally  another VI contains a single spark core  multiplexed  to control all eight 
10. DRIVVEN    Spark Driver Module Kit User s Manual    D000012 Rev F  January 2009       Drivven CompactRIO Spark Driver Module    Part    DO00012  8 Ch  Inductive Style ignition Coil Driver    o 0  N oO ao A U N       Drivven  Inc    12001 Network Blvd  Bldg E  Suite 110   San Antonio  Texas 78249   USA  Phone   210 248 9308  Web   www drivven com   E mail   info drivven com    Drivven  Inc  Spark Driver Module Kit    Contents   o A A E O EEEE 3  PES ESOO EI ness A E S 4  E A O no o II A 4  A AAN PP o o A 5  Hattotia  Comp alborada A 6  SPED e PPPPUO  0  ORCOOA cease cena o E A sess 7  JU AAA o e A 12  Crestino a LabVIEW PO birria 14  Subo VL DOCUMENTI O ness pios oo E EEEE 20  Spark Command Scheduling Notes sscicnccsoueivnssdazcerercteswdencandeedsevednssesaannenevassuencendendsoues este 23  Warning About FPGA I O Node Wiring     ccoooooocnccnnnncncnononocnnnnnnnnononnnnnnnnnnnnnnnnnnnnnnnncnnnnnnos 24       Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 2    Drivven  Inc  Spark Driver Module Kit    Introduction    The Spark Driver Module Kit provides a CompactRIO  cRIO  module for driving up to eight  ignition coils  The kit includes LabVIEW FPGA VIs for controlling all driver channels  individually  controlled for timing     Features    gt  8 channel inductive type ignition coil driver  Software configurable for dual output coils  wasted spark   7A primary peak current maximum per pulse  Short circuit protection  Internally fuse protected at 10A
11. GA I O Method Node  The Boolean indicator named  IDSelectOut must be connected to a Set Output Data method of an FPGA I O Method  Node  The remaining Boolean indicators must be connected to their corresponding  FPGA I O Node output item     SparkData Provides status indicators for the spark driver module     ModulePresent Indicates that the module is present in the correct slot  externally  powered and recognized by Drivven software     ModuleOverTemp Indicates that the module has exceeded its internal  temperature limit and temporarily shut down        Drivven  Inc  2009     Spark Driver Module Kit User s Manual   D000012   Rev F 22    Drivven  Inc  Spark Driver Module Kit    Spark Command Scheduling Notes    The Spark Vis provide features that ensure the best possible spark command delivery  even  while the CPU makes modifications to EndPosition and Dwell asynchronously to engine position     Modifications to Dwell  Dwell  MinDwell  OffTime     1  Dwell parameters can be modified at any time    2  If Dwell is modified during the main spark pulse to a value less than the previous  value of Dwell  then the pulse is continued until EndPosition    3  If Dwell is modified to a value less than MinDwell  0  for example   then the pulse  will still be started according to the value of Dwell and engine speed  but MinDwell  will take precedence by sacrificing the requested EndPosition to ensure a spark  occurs  This scenario should be avoided  Spark pulses should be disabled with the
12. a dwell time of 40 000 clock ticks  1 0 msec  such  that the spark pulse is scheduled to turn on at 150 ACAD  Let s also assume that  the CurrentPosition of the EPT VI is 140 ACAD when the CPU modifies  EndPosition to 120 ACAD  which means that the required start of the pulse is now  70 ACAD  This new start is in the recent past by 70 CAD  Since this is greater  than the 45 CAD History Window  the spark VI will not generate a late pulse   effectively skipping a cycle without a spark pulse  The following cycle will have a  pulse delivered starting at 120 ACAD     CutoffPosition must be set so that the following conditions are satisfied   1  Inthe case of non multiplexed spark Vis  CutoffPosition must be set at least 45  CAD after EndPosition  If this minimum spacing is not maintained  then spark  commands will be generated incorrectly        Driven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 23    Drivven  Inc  Spark Driver Module Kit    Warning About FPGA I O Node Wiring    Great care should be taken to ensure that I O nodes are wired to the correct Pininput and  PinOutput clusters of the correct module VI  If wired incorrectly  then undefined behavior or  module damage could result  LabVIEW FPGA does not yet provide a method for 3 party module  vendors to hide the DIO pins behind module VIs and still be portable to various system  configurations  Therefore  a double check of the I O node wiring is recommended     Two LabVIEW FPGA code snippets are sh
13. ach shared  primary  in parallel   Then use the two spark channels as if driving two independent  ignition coils        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 10    Drivven  Inc  Spark Driver Module Kit    Driver Channel Protections   The spark driver channels are short circuit protected  However  there is no short circuit fault  detection reported via software  If a short circuit is present  the driver channel will immediately  disable itself during the dwell command  Another driver attempt will be made at the next pulse   The driver channels are software limited to 5 msec of dwell  however  this may be much too long  for a given ignition coil  Therefore it is important that the user perform the above described bench  tests in order to fully understand the proper range of dwell time for a given ignition coil  Dwell  time should also be limited to approximately 25  duty cycle  For example  if an engine is running  at 8000 RPM  then the dwell time should be limited to 3 75msec  If wasted spark mode is  enabled or re strike pulses are enabled  the dwell time must be limited even more  For example   if an engine is running at 8000 RPM and wasted spark mode is enabled  then the dwell time  should be limited to 1 875 msec  If using double ended coils in wasted spark mode  and dwell  times are required to be greater than the maximum dwell calculated for wasted spark mode  then  two driver channels can be used to drive the same double ended igni
14. category   ii  Double click the desired target to add it to your project   b  New Target or Device     Expand the appropriate category in the    Targets and Devices    list to see  all possible targets within that category  ii  Double click the desired target to add it to your project    If the new FPGA target was not currently in the system  right click on the FPGA target   within the project and open the properties dialog to set the resource name if necessary    The resource name can be found from MAX when connected to the actual remote   system    10   If the FPGA target is a PXI or PCI card  then an R Series expansion chassis must be  added under the FPGA target  This is done by right clicking on the FPGA target and  navigating to    New  gt R Series Expansion Chassis     Within the following dialog  select the  appropriate FPGA connector to which the chassis will be connected  A unique name for  the chassis may also be specified    11  Right click on the R Series expansion chassis or cRIO FPGA target chassis and navigate  to    New  gt C Series Modules         12   Select the    New Target or Device    radio button and double click on the    C Series Module     in the    Targets and Devices    list  In the following dialog  select the desired Drivven  module at the bottom of the    Module Type    list  The Drivven modules will be appended  there if any Drivven module software has been installed  Select the appropriate module    2  Di  4         J             O           
15. ered terminals   However  the contents of the SparkControl cluster will vary     SparkControl  FuelSparkSupervisor   SparkPinInput    Figure 4  Spark VI icon with leads     SparkData  SparkPinQutput       The FPGA VI must be placed within a Single Cycle Loop  SCL  of a LabVIEW FPGA block  diagram  The SCL must execute at the default clock rate of 40 MHz        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e DO00012   Rev F 12    Drivven  Inc  Spark Driver Module Kit    The FPGA VI requires a pre synthesized netlist file having a matching name and an extension of   ngc  The netlist file must be located in the same directory as the matching VI  The installer will  place this file in the LabVIEW addons directory along with the FPGA VI        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 13    Drivven  Inc  Spark Driver Module Kit    Creating a LabVIEW Project    Drivven recommends working from the provided example application as a starting point for  learning the use of the Drivven software blocks  However  the following section describes starting  a LabVIEW project from scratch and adding a Drivven module     1   Install the Drivven software by running the installer executable and accepting the   software license agreement    Restart LabVIEW  if previously running  and create a new LabVIEW project    Give the new project a name by clicking the    Save Project    button on the project toolbar    Right click on the highest item in the p
16. gram Files National Instruments LabVIEW X X vi lib addons DrivvenProductRelease      When working with block diagrams  user   s will notice a    Drivven    function palette added to the  standard LabVIEW palette  specific for the RT or FPGA target  VIs for a specific Drivven product  will be categorized according to product name  Also  some Drivven products will install RT and  FPGA VIs under a    General    function palette which is intended to be used across multiple  products     Requirements   The Drivven VIs require    LabVIEW 8 5 Full Development or later  LabVIEW RT Module 8 5 or later  LabVIEW FPGA Module 8 5 or later  NI RIO 2 4 or later   Drivven EPT VI       VVVV V       The FPGA VI supplied with this kit cannot generate fuel commands without the supervision of an engine  position tracking  EPT  VI from Drivven  The EPT VI provides the necessary output cluster to be wired to  the FuelSparkSupervisor input cluster     The Spark Driver Module Kit is provided with 14 different LabVIEW FPGA VIs  Each VI includes  an interface for controlling a different number of spark channels with non multiplexed or  multiplexed internal spark control cores  This gives the user the ability to optimize FPGA  resources depending upon maximum engine speed and dwell requirements  There is also a  WasteSpark control input which allows the use of dual output ignition coils for pairs of opposing  cylinders     Figure 4 shows the icon which represents all supplied VIs  having identical clust
17. ition  This is an approximate rule  and should be retarded out further if engine speed fluctuations are enough that  pulses are being cut short  For non multiplexed Vis  CutoffPosition MUST  ALWAYS be at least 45 CAD after EndPosition  If the minimum spacing of 45  CAD is not maintained for non multiplexed VIs  then spark commands will be  generated incorrectly  The units of CutoffPosition are CAT     Drivven provides Offset2CAT vi in the General RT VIs in the RT function palette   This VI can be implemented at the LabVIEW RT level for converting  CutoffPosition in CAD  with respect to a cylinder TDC  to CAT     Dwell Determines the length of the spark command delivered to the driver circuit   Dwell is entered in terms of 40 MHz clock ticks and is internally limited to  200 000 ticks  5 msec   The value is also internally limited to 18 bits  Values  larger than 18 bits will roll over from zero     Dwell uint32 ticks    Dwell msec    40 000     Drivven provides time2ticks vi in the General RT VIs in the RT function palette   This VI can be implemented at the LabVIEW RT level for converting time in  milliseconds to 40 MHz clock ticks     OffTime Determines the length of inactivity following each spark pulse  It is  recommended to set this value to at least 100 usec  OffTime provides a  minimum amount of time for the command to be off to allow the actual spark to  occur before turning the coil back on  OffTime is entered in terms of 40 MHz  clock ticks and is internally limited 
18. k tester device     Using the built in simulator feature of the Engine Position Tracking VI  the user can simulate a  running engine and generate sparks on a test bench by connecting a test coil to a spark driver  channel and a spark tester device to the coil  A spark tester device is a low cost tool sold at most  auto parts stores which fits into the boot of a coil or plug lead just like an ordinary spark plug  The  gap of the tester is adjusted by a threaded rod with a pointed tip  The body of the spark tester is  marked for approximate gap voltages  The tester shown in Figure 2 is made by Thexton  part   404  and is sold for approximately  10 USD  The spring clip must be connected to battery  ground to provide a ground path for the spark  If the spark does not have a ground path back to  battery  then there will not be a spark seen at the gap  Instead  the ignition coil will arc within  itself and could cause damage to the coil        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 7    Drivven  Inc  Spark Driver Module Kit       Figure 2  Thexton adjustable spark tester  Part  404     WARNING  Automotive ignition coils can generate lethal voltages  The user should be  extremely careful when handling the ignition coil  spark plug or spark testing device  Do  not touch the coil or spark tester device while performing spark tests  Do not attempt to  adjust the spark tester while performing spark tests  Remove power to the ignition circuit  before
19. le one cylinder is at top dead center compression  the pairing       Drivven  Inc  2009   Spark Driver Module Kit User s Manual e DO00012   Rev F 21    Drivven  Inc  Spark Driver Module Kit    cylinder is at top dead center exhaust  A dual output coil will spark in both  cylinders at the same time  sparking into a combustible mixture in one cylinder   while sparking into inert exhaust gases in the other  When WasteSpark is TRUE   the number of available spark channels will be divided by 2  For example  in the  case of using an eight channel spark VI  only the first four driver channels would  be used instead of all eight  Pulse 1 will be paired with pulse 5 on channel 1   pulse 2 paired with pulse 6 on channel 2  pulse 3 paired with pulse 7 on channel  3  and pulse 4 paired with pulse 8 on channel 4  If using the waste spark mode   and the dwell time per channel is greater than 25  duty  then WasteSpark  should be set to false and two spark channels should be used to drive the same  coil primary     FuelSparkSupervisor This cluster input must be wired directly from the  FuelSparkSupervisor cluster output of a Drivven EPT VI  The FuelSparkSupervisor  cluster from a single EPT may be used to supervise any number of Drivven engine   synchronous output sub VIs     SparkPininput These Boolean controls must be connected to their corresponding FPGA  I O Node input item     SparkPinOutput The Boolean indicator named IDSelectEn must be connected to a Set  Output Enable method of an FP
20. modules from Drivven are compatible within two different platforms from National  Instruments  One platform is CompactRIO  consisting of a CompactRIO controller and  CompactRIO chassis as shown in Figure 1a below        Figure 1a  CompactRIO platform compatible with Drivven CompactRIO modules     The other platform is National Instruments PXI which consists of any National Instruments PXI  chassis along with a PXI RT controller and PXI 78xxR R Series FPGA card  An R Series  expansion chassis must be connected to the PXI FPGA card via a SHC68 68 RDIO cable  The  CompactRIO modules insert into the R Series expansion chassis  This platform is shown in  Figure 1b below          et   T arenes Peo i oye  T yr 7    NA TF    e PEE        1       Figure 1b  PXI platform compatible with Drivven CompactRIO modules     Drivven CompactRIO modules are not compatible with the National Instruments CompactDAQ  chassis     Drivven CompactRIO modules REQUIRE one of the hardware support systems described above  in order to function  The modules may not be used by themselves and or interfaced to third party  devices at the backplane HD15 connector  These efforts will not be supported by Drivven or  National Instruments        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e DO00012   Rev F 6    Drivven  Inc  Spark Driver Module Kit    Spark Drivers    Each spark driver channel is capable of directly driving a single ignition coil primary and is  independently controlled for timing and
21. n  Inc  Spark Driver Module Kit    Brief Glossary of Terms   CAD  Crank Angle Degrees  There are 360 CAD per two stroke cycle or one crankshaft rotation   There are 720 CAD per 4 stroke cycle  or two crankshaft rotations  In a 4 stroke engine  the  camshaft completes exactly one rotation per two rotations of the crankshaft  There are two  strokes of the piston  up and down  within the cylinder during a single rotation of the crankshaft   A single stroke of the piston covers 180 CAD     EXTRAP  Level of EPT Position Extrapolation  This is a fixed power of two by which the angular  resolution of tracked crankshaft position is improved over the physical teeth alone  For example   if the EPT VI has a fixed extrapolation level of 7  then the crank angle resolution between each  physical tooth is improved by a factor of 2 7   128     CAT  Crank Angle Ticks  Single unit of angular measure reported by the CurrentPosition output  of the EPT VI  Reported as a power of two angular ticks of crank position travel  having a  resolution dependent on EXTRAP and the number of physical teeth per crankshaft rotation  For  example  if using the N M EPT VI  which has an extrapolation of 7  the number of CAT per crank  tooth would be 2 7 128  and CurrentPosition would be evenly incremented by 128 CAT from one  physical tooth to the next  If a 60 2 pattern were used  the maximum number of CAT per  crankshaft rotation  cycle  would be 60 128 7680  If the engine was a 4 stroke  the total number  of C
22. outputs  The VI chosen will depend upon the maximum dwell required for the  ignition coil and the maximum engine speed  The VI which has 8 spark cores will require more  FPGA resources than the VI which has a single spark core  If the non multiplexing VI   spark_vt_8mux1_revx vi  is chosen  then it is possible for all soark outputs to overlap  Ifa  multiplexing VI is chosen  then consideration must be given to dwell and engine speed to ensure  that consecutive spark pulses generated by the same spark core will not interfere  The plots in  figures 5   8 show how the spark cores are multiplexed for each of the four eight channel VIs        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 17    Drivven  Inc  Spark Driver Module Kit    SparkCore1 f 1         SS     SparkCore2 Of eee  SparkCore3 A EE Lo  SparkCore4 A E    SparkCore7 A ooo oo  SparkCore8 A 8    tt    0 90 180 270 360 450 540 630    CAD  Pulse numbers note the spark output channel    Figure 5  spark_vt_8mux1_revx vi contains 8 non multiplexed spark cores     SparkCore1 O A E  SparkCore2 Of O o i y i i fab  SparkCore3 O O E A A  SparkCore4 OM eee E   tt    0 90 180 270 360 450 540 630    CAD  Pulse numbers note the spark output channel    Figure 6  spark_vt_4mux2_revx vi contains 4 spark cores multiplexed into 2 outputs each     SparkCore1 1 3 5 7  SparkCore2 2 4 6 8  es A AAA A A O PS A ee  0 90 180 270 360 450 540 630  CAD    Pulse numbers note the spark output channel  Figure 7  spark_v
23. own below from an ADCombo implementation which  illustrate this issue  Figure 9 shows the correct implementation of the FPGA I O node block for  the PinOutput cluster of the ADCombo  On the other hand  figure 10 shows a coding mistake that  should be avoided  Notice the ADCombo output items where a Spark module output item is  selected instead of the correct ADCombo module output item  This means that the Spark  DIO5   output is being driven by the ADCombo logic and will cause strange behavior of the spark  module  or possible damage              IDSelectEn        S im   ADComba SPI Clk  os ET ADComba SPI CS  DIO5  E  DIO  F JUL ADCombo SPI MOSI  DIO7         Figure 9  Representative FPGA output node for ADCombo with correct output item selection     IDselectEn   EA  IDselectOut    oP ADCombo sPrCk_ 5  DIOS r Mu  Spark SPICS  DIOS        PIU ADCombo SPI MOSI  DIO7       DIO     Figure 10  Representative FPGA output node for ADCombo with incorrect output item selection  for DIO5  This will cause strange behavior or damage to the spark module  Applying meaningful  names to the modules within the project can help identify these coding mistakes        Drivven  Inc  2009     Spark Driver Module Kit User s Manual   D000012   Rev F 24    
24. rent requested Dwell and the current engine  speed  EndPosition will always take precedence over Dwell in the presence of  engine speed fluctuations  If the engine speed increases after the spark pulse  has started  then the actual dwell will be slightly shorter than the requested Dwell  to ensure that correct spark timing is achieved  Likewise  if the engine speed  decreases after the spark pulse has started  then the actual dwell be will slightly  longer than the requested Dwell  However  MinDwell will take precedence over  EndPosition to ensure that a spark occurs  even if it is late  Also  a maximum  dwell of 5 msec is enforced to protect the driver circuit  even if the end of the  spark pulse must occur before EndPosition  The units of EndPosition are CAT     Drivven provides Offset2CAT vi in the General RT VIs in the RT function palette   This VI can be implemented at the LabVIEW RT level for converting spark  advance in CAD  with respect to a cylinder TDC  to CAT     CutoffPositionX All spark pulse activity is  Cutoff  at CutoffPosition and reset for  the next pulse  For multiplexed Vis  CutoffPositon is the position at which the  next consecutive spark pulse parameters will be loaded for the given internal  spark core  For multiplexed Vis  CutoffPosition should be set to a position close       Drivven  Inc  2009     Spark Driver Module Kit User s Manual   D000012   Rev F 20    Drivven  Inc     Spark Driver Module Kit    to  but after the most retarded spark timing pos
25. roject hierarchy     Project         and navigate to      New  gt Targets and Devices         5   Within the    Add Targets and Devices       dialog  select the appropriate radio button   depending on whether you already have an existing powered and configured RT target  on the network or if you are adding a new RT target which is not present yet on the  network    a  Existing Target or Device     Expand the appropriate category in the    Targets and Devices    list to see  the discovered targets in that category   ii  Double click the desired target to add it to your project   b  New Target or Device  i  Expand the appropriate category in the    Targets and Devices    list to see  all possible targets within that category   ii  Double click the desired target to add it to your project    6   If the new RT target is not currently on the network  right click on the RT target within the  project and open the properties dialog to set the IP address or DNS name if necessary    7   Right click on the RT target within the project and navigate to    New  gt Targets and   Devices         Within the    Add Targets and Devices       dialog  select the appropriate radio button    depending on whether you already have an existing FPGA target connected to an   existing RT target or if you are adding a new FPGA target which is not present yet   a  Existing Target or Device  i  Expand the appropriate category in the    Targets and Devices    list to see  the discovered FPGA targets in that 
26. st  Connect the coil secondary to the  spark tester device  This connection will vary with coil and test device  Be sure to connect the  other side of the spark tester device back to battery ground     The user should adjust the spark tester for a spark voltage of 10 20 kvolts  Then starting with a  dwell time of approximately 0 1 msec  increase the dwell until spark is achieved  Use the current  probe to double check that current limits are not being exceeded as dwell is increased  For  example  if the tester device were not connected properly for some reason  the user would see  current increasing with dwell  but never see a spark  and appropriate measures could be taken to  discover the problem  The dwell required for a 10 20 kvolt spark is most likely sufficient for  achieving reliable combustion at moderate to high loads  Of course this requirement will vary with  many different factors  but this test will provide the user with a typical dwell time for the given  ignition coil  During engine operation  required dwell time will depend on battery voltage  As  battery voltage decreases  dwell time must increase to achieve the same spark energy  The user       Drivven  Inc  2009   Spark Driver Module Kit User s Manual e DO00012   Rev F 8    Drivven  Inc  Spark Driver Module Kit    can perform a bench test with a variable power supply to determine how dwell time depends on  battery voltage  These values can be implemented in a lookup table in LabVIEW using Drivven s  RT table
27. t_2mux4_revx vi contains 2 spark cores multiplexed into 4 outputs each     SparkCore1 1 2 3 4 5 6 7 8      O O O  0 90 180 270 360 450 540 630  CAD    Pulse numbers note the spark output channel  Figure 8  spark_vt_1mux8_revx vi contains 1 spark core multiplexed into 8 outputs        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 18    Drivven  Inc  Spark Driver Module Kit    NOTE  The pulse output numbers shown in the plots above do not correspond to cylinder  numbers  There should be no attempt at cylinder number correlation to output channel  number  The reason is that spark channels must be configured with timing values in  sequential CAD order  NOT cylinder number order     In order to determine which spark VI can be used  the following calculations should be performed   Assume EPT Stroke   4  MUX   8  1mux8   Maximum engine speed   6000 RPM    MinDwellWindow  sec     60   STROKE     2   MUX   MaxEngineSpeed RPM       60   4     2   8   6000     0 002500 sec   If MinDwellWindow is calculated to be less than the actual dwell required by the ignition coil  then   a VI should be selected with less multiplexing and the calculation should be performed again   using the corresponding MUX value  Do not forget to consider minimum battery voltage when   determining maximum dwell required by the coil        Drivven  Inc  2009   Spark Driver Module Kit User s Manual e D000012   Rev F 19    Drivven  Inc  Spark Driver Module Kit    Sub VI Documentation  
28. tion coil  with wasted spark  mode disabled     The spark driver module is internally protected from board temperature exceeding 85 degC   When this temperature is exceeded  all driver activity will be shutdown until the temperature  drops to 55 degC  The over temperature condition is reported by the SparkData cluster output of  the FPGA VIs        Drivven  Inc  2009     Spark Driver Module Kit User s Manual   D000012   Rev F 11    Drivven  Inc  Spark Driver Module Kit    Software Installer    The Spark Driver Module Kit is provided with an installer package which may be downloaded  from Drivven s Sharepoint website after obtaining login access from Drivven  User s may go to  http   portal drivven com SoftwareDownload and enter the provided username and password to  gain access to the specific product installer packages which have been purchased  The installer  packages are executables which should be run on the intended development computer  having  LabVIEW development tools installed  After installing the package  a    Start  gt Programs  gt Drivven    gt ProductRelease    menu item will be added to the desktop  The specific product will have an  example LabVIEW project appear under the    Examples    menu and the user manual will appear  under the    Manuals    menu  User s may copy and open the example project to experiment with  the module or use as a starting point for a new application  All software files  example projects  and documentation are installed to     C  Pro
29. to 16 bits  Values larger than 16 bits will roll  over from zero     Dwell uint32 ticks    Dwell msec    40 000     Drivven provides time2ticks vi in the General RT VIs in the RT function palette   This VI can be implemented at the LabVIEW RT level for converting time in  milliseconds to 40 MHz clock ticks     MinDwell Determines the minimum length of any spark pulse  It is possible that  dwell could be cut short of the requested Dwell due to engine speed fluctuations  or modifications to EndPosition  If MinDwell is not satisfied upon reaching  EndPosition  then the pulse will be extended until MinDwell  This will ensure that  a spark will always occur even if the timing is late  MinDwell should be set to a  minimum value of dwell that will still guarantee a spark  MinDwell is entered in  terms of 40 MHz clock ticks and is internally limited to 200 000 ticks  5 msec    The value is also internally limited to 18 bits  Values larger than 18 bits will roll  over from zero    The following equation applies for converting dwell times in milliseconds to 40  MHz clock ticks     Dwell uint32 ticks    Dwell msec    40 000     Drivven provides time2ticks vi in the General RT VIs in the RT function palette   This VI can be implemented at the LabVIEW RT level for converting time in  milliseconds to 40 MHz clock ticks     WasteSpark The WasteSpark input allows users to take advantage of dual  output coils that operate on a pair of 4 stroke cylinders that are 360 degrees out  of phase  Whi
30. uld range from a few hundred microseconds to four milliseconds  The  voltage actually required for combustion will also depend on other engine parameters  This spark  driver module is intended to be used to drive a wide variety of ignition coils  but the user must  understand the proper range of dwell times for the coil used or damage to the coil and driver  could occur  It should also be understood that longer dwell time does not necessarily correlate to  better combustion  The dwell time only needs to be long enough to achieve a reliable spark  under the engine operating conditions and battery voltage  More dwell time  in excess of what is  needed to achieve reliable spark  wastes energy and needlessly heats the driver module     Determining Dwell Time   The best way to determine required dwell time for a specific coil application is to measure the  dwell of the coil within an OEM installation  While performing measurements  be sure to measure  the dwell of at least three different battery voltages  if possible  in order to build a table of dwell  times versus battery voltage  If a datasheet is available for the coil  a table of dwell versus  battery voltage may be provided in order to achieve a certain peak current in the primary     It is possible to safely determine the required dwell time for a given ignition coil by performing a  simple bench test  The test will require a variable voltage power supply capable of 7 peak amps   an oscilloscope  a current probe and a spar
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  m。squit。 buster  Samsung Galaxy S5 mini Felhasználói kézikönyv  Sistemas de Domótica.  GE 591 Clothes Dryer User Manual  MB075BH rev2 - Catalogue.bosal.com  Saneamento Básico Integrado às Comunidades Rurais e  AVC-5 Manual rB 9-8-11.vp  JVC LT-17B60SU User's Manual  Lenovo IdeaPad U330 Touch    Copyright © All rights reserved. 