Home

Siemens BT300 I/O Option Board Type “B”

image

Contents

1. STOP READY Keypad G Main Menu M3 ID SF Quick Setup 17 ey Monitor 5 Parameters 12 STOP READY Keypad Digital Inputs 1D 404 M3 5 1 2 3 Ctrl Signal 1 A st DigIn SlotA 1 A Ctrl Signal 2A On E DigIn Slot0 1 5 Ctrl Signal 1 B st DigIn Slot0 1 STOP READY Keypad Parameters Gi 2 ID M3 5 References 18 Ramps and Brakes 7 Ci I O Config 4 STOP READY Keypad Ctrl signal 2A Bi ID M3 5 1 2 O Help Y Add to favorites STOP READY Keypad I O Config ID M3 5 1 Analog Inputs 36 Digital Outputs 1 STOP READY Keypad Ctrl signal 2 A ST 1D 404 M3 5 1 2 A v DigIN Slot0 1 Min Max button Change the value The editable part of the value DigIN Slot0 1 is underlined and blink ing Change the slot or assign to Time Channel with the arrow keys up and down Make the terminal value 1 editable by pressing the right key once and change the value with 2 arrow keys up and down Accept the change with OK button or return to previous menu level with BACK RESET A Be ABSOLUTELY sure not to connect the two functions to one and the same output
2. Description of type B boards Siemens Industry Inc 25 3 7 2 OPTBH option board wiring scheme Use shielded cables and connect the cable shield to grounding clamp in the drive Allowed sensor configurations are shown in the figures below 123 4 5 6 7 8 910 1234567 8 910 ee hee L LL mE EE BE Two wire configuration Three wire configuration 123456 7 8 910 123 4 5 6 7 8 910 lm lm l s ee a m E ss Two wire configuration Three wire configuration 3 7 3 OPTBH board parameters NOTE The correct sensor for the correct channel must be selected Always configure unused channels to 0 No sensor Code Parameter Min Max Unit Default ID Description 0 No Sensor 1 PT100 2 PT1000 7 x 1 1 Sensor 1 type 0 6 0 3 Ni1000 4 KTY84 5 2xPT100 6 3 x PT100 7 x 1 2 Sensor 2 type 0 6 0 See above 7 x 1 3 Sensor 3 type 0 6 0 See above 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 26 Description of type B boards 24 hour support 1 800 877 7545 Dial 2 DPD01158A Part No DPD01158A Copyright O 2013 Siemens Industry Inc www sbt siemens com
3. O ago OM ak ta Fl O Ten 5 HB O E s O E nl o le HE oe 7 S a FE a O la Jumper X4 Description Option board with six bidirectional terminals Type ID 16945 Terminals One terminal block Screw terminals M2 6 No coding Jumpers 2 X2 and X4 3 1 1 I O terminals on OPTB1 Table 5 OPTB1 1 0 terminals OPTB1 Terminal Signal Parameter reference Technical information 1 Digital input DIO1 DigIN SlotX 1 Digital input 24V R gt 5kQ Digital output DIO1 DigOUT SlotX 1 Digital output Open collector 50mA 48V 2 Digital input DIO2 DigIN SlotX 2 Digital output DIO2 DigOUT Slotx 2 5 above 3 Digital input DIO3 DigIN SlotX 3 Digital output DIO3 DigOUT Slotx 3 5 above 4 Common for DIO1 DIO3 CMA NOTE CMA is internally connected to GND with jumper by default 5 Digital input DIO4 DigIN SlotX 4 Digital input 24V R gt 5k02 Digital output DIO4 DigOUT SlotX 4 Digital output Open collector 50mA 48V 6 Digital input DIO5 DigIN SlotX 5 Digital output DIO5 DigOUT Slotx 5 5 above 7 Digital input DIO6 DigIN SlotX 6 Digital output DIO6 DigOUT Slotx 6 above 8 CMB Common for DIO4 DIO6 GND I O ground Ground for reference and controls 10 24V Control voltage output Voltage for switches etc max current 150mA Short circuit protected NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter d
4. 250VAC 8A 26 RO2 normal open DigOUT SlotX 2 125VDC 0 4A Min switching load 5V 10mA 28 Tl1 y Thermistor input galvanically isolated 29 TM Aa IR apin AIO NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter depends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Description of type B boards 3 3 Board OPTB4 Description Type ID Terminals Jumpers 3 3 1 O O O O O O O O O O 04686 8 2 9 Sy amp eer Siemens Industry Inc 19 I O expander board with one galvanically isolated analog input and two galvanically isolated analog outputs standard signals 0 4 20mA 16948 One terminal block Screw terminals M2 6 No coding None 1 O terminals on OPTB4 Table 7 OPTBA 1 0 terminals Terminal Signal Parameter reference Technical information OPTB4 1 Al1 AnIN SlotX 1 0 4 20mA R 2500 galvanically isolated 2 Al1 Resolution 10 bits 0 1 Accuracy 1 of the full display 3 AO1 ANOUT SloiX 1 0 4 20mA R lt 500Q Resolution 10 bits 0 1 4 AO1 Accuracy lt 2 galvanically isolated 5 AO2 ANOUT SloiX 2 0 4 20mA R lt 500Q Resolution 10 bits 0 1 6 AO2 Accuracy lt 2 galvanically isolated 7 GND 24VDC 15 Max load 250mA total load from EXT 24V outputs max 150mA from one board See 8 GND Figure 1 on page
5. E Close the inner cover BT3043A 24 hour support 1 800 877 7545 Dial 2 Installation of option boards Siemens Industry Inc 11 2 2 Prepare for use We recommend to ground the control cables in the manner presented below Note that the images are sug gestive because the cables can vary Strip about 15 mm 6 in of the cable and cut off the grey cable shield Remember to do this for both cables Leave no more than 10 mm 4 in of the cable outside the terminal block and strip the cables at about 5 mm 2 in to fit in the terminals See picture below 10 4 BT9189 5 2 3 Also strip the cable now at such a distance from the terminal that you can fix it to the frame with the grounding clamp Strip the cable at a maximum length of 15 mm 6 Do not strip the aluminum cable shield 4 Then connect the cable to its appropriate terminals on the option board terminal block Using the cable clamp included in the delivery of the drive ground the shield of the option board cable to the frame of the drive Cable clamp 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 12 Installation of option boards Unless already done for the other control cables cut free the opening on the drive cover for the option board cable protection type 1 class IP21 NOTE Cut the
6. a ne ne nt a 20 Bod ma e e NE 21 I O terminals on OP TBO asea e eare E aa aae aa aaaea Eaa a Eae 21 BOOTS A EE OO 22 I O terminals on OP TBF reier ae E aa aa en aana a aE 22 Jumper selsctions iria iaa tdi 23 Board OP BB isa 24 IO Termin ls ON OPT Brian Willa caer alae aye alia 24 OPTBH option board wiring scheme 25 OP TBH board parameters citada lidad 25 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 2 24 hour support 1 800 877 7545 Dial 2 General information Siemens Industry Inc 3 1 General information The Siemens BT300 product range comes with a wide selection of expander boards with which the available I O of Siemens BT300 variable frequency drive can be increased and its versatility improved The input and output configuration I O of the Siemens BT300 is designed with modularity in mind The total I O is comprised of standard and option boards each having its own input and output configuration The boards contain analog and digital inputs and outputs and additional application specific hardware 1 1 Board slots on the Siemens BT300 The control board is located inside the control unit of the BT300 drive There are two board slots labeled D and E on the Siemens BT300 control board To locate the slots see page 10 See also the descriptions of the option boards in Chapter 3 Usually when the drive is delivered from the factory the control unit includes at least the standard board w
7. gt 35V 6 COMA Common for inputs Switching capacity 24VDC 8A y odd DigOUT SlotX 5 250VAC 8A P 125VDC 0 4A NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter depends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 22 Description of type B boards 3 6 Board OPTBF Jumper X2 L OOO ve Description I O expander board with analog output digital output and relay output Type ID 16966 Terminals Two terminal blocks Screw terminals M2 6 and M3 No coding Jumpers 1 X2 3 6 1 I O terminals on OPTBF OPTBF 1 AO1 AnOUT SlotX 1 0 4 20mA R lt 500 Resolution 10 bits 0 1 Accuracy lt 2 Not isolated 0 2 10V R lt 1k0 Resolution 10 bits 0 1 2 ROT Accuracy lt 2 Non isolated mA V selection with jumper X2 3 DO1 DigOUT SlotX 1 Digital output Open collector 50mA 48V Not isolated 4 GND Switching capacity 24VDC 8A 22 RO1 Common DigOUT SlotX 2 250VAC 8A 23 RO1 normal open 125VDC 0 4A Min switching load 5V 10mA Table 10 OPTBF I O terminals NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter de pends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Description of type B boards Siemens Industry Inc 23 3 6 2 Jumper selections O
8. in order to avoid function overruns and to ensure flawless operation NOTE Changes to input cannot occur when the drive is in the RUN state 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 8 General information 24 hour support 1 800 877 7545 Dial 2 Installation of option boards Siemens Industry Inc 9 2 Installation of option boards With B type boards make sure that the sticker on the connector of the board says dv dual voltage This indicates that the board is compatible with the Siemens BT300 drives mentioned in this manual See below NOTE Incompatible boards cannot be installed on the BT300 drives Compatible boards have a slot coding that enable the placing of the board see below OPTBx dv Ci SLOT CODING BT3042 2 1 Installation NOTE Don t add or replace option boards or fieldbus boards on a variable frequency drive with the power switched on This may damage the boards Open the cover of the drive The relay outputs and other l O terminals may have a dangerous control voltage present even when the BT300 drive is disconnected from mains DANGER 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 10 Installation of option boards Open the inner cover 1 to reveal the option board slots D E and install the option board 2 into slot D or
9. opening on the same side you have installed the board in Remount the drive cover and run the cable as shown in picture NOTE When planning the cable runs remember to keep the distance between the option board cable and the motor cable at a minimum of 30 cm 11 8 in It is recommended to route the option board cables away from the power cables as shown in the picture NS Option board cables 24 hour support 1 800 877 7545 Dial 2 Installation of option boards Siemens Industry Inc 13 2 3 Control cables The control cables used shall be at least 0 5 mm 20 AWG screened multi core cables The maximum ter minal wire size is 2 5 mm 14 AWG for the relay terminals and other terminals Find the tightening torques of the control and relay board terminals in Table 2 below Tightening torque Terminal screw All 1 O and relay terminals screw M3 0 45 4 00 Table 2 Control cable tightening torques 4st environment 2nd environment Cable type EMC levels VE According to EN61800 3 2004 Category C2 Category C3 Control cable 4 4 4 Table 3 Cable types required to meet standards 4 Screened cable equipped with compact low impedance shield JAMAK SAB ZCuY O or similar 2 4 Board information sticker Each I O option board package delivered by the factory includes a sticker shown below where possible mod ifications made in the variable freque
10. type B boards Siemens Industry Inc 21 3 5 Board OPTB9 O BE gn E m A O N z frr O R21 al 4gU ee 4 co O E i o m BE N rs I LEA Ea O al rss 8 eer BE 3 foe m id Fe Eg ua OSA an a O o A Bl i i kt B on a Og RE Description I O expander board with five 42 240 VAC digital inputs and one relay output Type ID 16953 Terminals One terminal block Screw terminals M2 6 No coding Jumpers None 3 5 1 I O terminals on OPTB9 Table 9 OPTB9 I O terminals OPTB9 Terminal Signal Parameter reference Technical information i Digital input 42 240 VAC threshold 35V 1 ACID DigIN SlotX 1 Control voltage 0 lt 33V 1 gt 35V Digital input 42 240 VAC threshold 35V 2 ACIN2 DigiN SlotX 2 Control voltage 0 lt 33V 1 gt 35V Digital input 42 240 VAC threshold 35V 3 AGINS DigiN SlotX 3 Control voltage 0 lt 33V 1 gt 35V Digital input 42 240 VAC threshold 35V 4 ACIN DigiN SlotX 4 Control voltage 0 lt 33V 1 gt 35V i Digital input 42 240 VAC threshold 35V 5 ACINS DigiN SlotX 5 Control voltage 0 lt 33V 1
11. 5 9 GND 24VDC 15 in special applications where PLC type functions are included in the control module this input can 10 24V be used as external auxiliary power supply for control boards as well as for I O boards NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter depends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 20 Description of type B boards 3 4 Board OPTB5 Description Type ID Terminals Jumpers 3 4 1 ENES ET ZZ I O expander board with three relay outputs 16949 Three terminal blocks Screw terminals M3 No coding None I O terminals on OPTB5 Table 8 OPTB5 I O terminals OPTB5 Terminal Signal Parameter reference Technical information Switching capacity 24VDC 8A 22 RO1 common r 250VAC 8A 23 RO1 normal open DigOUT SONET 125VDC 0 4A Min switching load 5V 10mA Switching capacity 24VDC 8A 25 RO2 common A 250VAC 8A 26 RO2 normal open Be et 125VDC 0 4A Min switching load 5V 10mA Switching capacity 24VDC 8A 28 RO2 common 250VAC 8A 29 ROZ2 normal open DigOUT SlotX 3 125VDC 0 4A Min switching load 5V 10mA NOTE The X given in the Parameter reference shall be replaced by the slot letter The letter depends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Description of
12. SIEMENS Siemens BT300 I O Option Board Type B User Manual www sbt siemens com 1 1 1 1 2 1 2 1 1 2 2 1 2 3 1 2 4 1 2 5 1 2 6 O1 O1 aww x a N aaa Siemens Industry Inc 1 Table of contents Document DPD01158A Rev A Version release date February 22 2013 General information ii eta 3 Board slots on the Siemens BT300 ooooccccccnncnnnnnnnnnnnnnnnennnnnnnnnnnenonnnnnnnnnnnnnninineneninininen 3 Option board type Besos csi ea cunts 3 Board type B tecniniGal datan cal o 3 E een ON 4 Analog OPUS actas dd drid 4 A oemiantdskedda edge 4 Control voltage F2 VDC csc re te AA Ada 4 Digital input signal CONVersions iu een 4 Hardware protection iu A AAA A eia ieda 6 Ferminal DOCK COINS ES an es nds dr ne 6 Type identification numbers A abate 6 Defining functions to inputs and outputs programming ccccccccononoconcncncnnnnnanananonnnoninnns 6 Example programming veia 6 Installation of option boards 9 Installation er Em D de 9 Prepare for USE aiii A vag este lovey vey ae ns 11 Controlkcables aar raste Ens direktorater se das rs 13 Board information sticker 13 Description of type B boards nnmnnn nnne 15 Bod PTBN 16 I O termin ls on OPT B11 renn a A E 16 Jumper selections aii ai 17 Board OPTB2 i 18 VOderminals On O P BZ a O eking anla 18 Board OPTB4 SA E T E T E E A A 19 I O terminals on OPTB4 33 3 A A a en as 19 Board OP TBS iio 20 lO terminals On OPTBB usuniete e a
13. al terminals assigned only for certain function You can choose the terminal of your choice for the specific function in other words functions appear as operator defined parameters 1 5 1 Example programming The selectable values of the parameters programmed are of type DigIN SlotA 1 in which DigIN stands for digital input Slot_ refers to the board either Siemens BT300 drive basic boards A or B or D and E which are option boards see figure 4 The parameter signal is not connected to any terminal i e it is not used if instead of a letter the word Slot is followed by a 0 for example DigIN Slot0 1 The number after the board letter refers to the respective terminal on the selected board Hence DigINSlotA 1 means terminal DI1 on the basic board in board slot A 24 hour support 1 800 877 7545 Dial 2 General information Option ET board slot D EXAMPLE Bi Figure 4 Option board slots Siemens Industry Inc 7 Option board slot E You want to connect the Control signal 2 A parameter M3 5 1 2 to digital input DI2 1 Locate the parameter Control signal 2 A M3 5 1 2 on the keypad
14. boards of type B are used with current mA signal only However on some cer tain option boards the signal type mA V can be selected with a jumper dip switch See more detailed infor mation on individual boards in chapter 3 1 2 5 Control voltage 24VDC The control voltage output 24V EXT 24V can be used in two ways Typically the 24V control voltage is wired to digital inputs through an external switch The control voltage can also be used to power up external equipment such as encoders and auxiliary relays Observe that the specified total load on all available 24V EXT 24V output terminals must not exceed 250mA The 24V EXT 24V outputs can further be used to externally power up the control board as well as option boards If an external power supply is connected to EXT 24V output the control board and option boards remain live even if mains should be lost on the variable frequency drive This ensures sufficient functioning of the control logic not the motor control however and some alarms in exceptional power loss situations Fur thermore fieldbus links remain powered which enables the Fieldbus Master to read valuable data on the vari able frequency drive NOTE The power unit is not powered through the EXT 24V and therefore the motor control does not work if the mains is lost Requirements for an external power back up output voltage 24VDC 10 max ripple voltage 100mV RMS max current 1A 1A external fuse no int
15. control boards as well as I O boards 10VDC 0 2 max 10mA Analog output AO current mA Analog output AO voltage V Relay outputs RO Thermistor input TI 0 4 20mA R lt 5000Q resolution 10 bits 0 1 accuracy 2 0 2 10V Ry gt 1kQ resolution 10 bits accuracy 2 Switching capacity 24VDC 8A 250VAC 8A 125VDC 0 4A Max continuous load 2A rms Min switching load 5V 10mA Rtrip 4 7KQ PTC type 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 4 General information 1 2 2 Isolation The control connections are isolated from the primary output voltage and the I O ground is connected directly to the frame of the variable frequency drive Digital inputs and relay outputs are isolated from the I O ground For digital input arrangements see Chapter 1 2 6 Digital input signal conversions on page 4 1 2 3 Analog inputs The analog inputs of the type B boards can be used as either current inputs or voltage mA V inputs see detailed description of each board The signal type is selected with a jumper block on the board In case the voltage type input is used you still have to define the voltage range with another jumper block The factory default value for the analog signal type is given in the description of the board For detailed information see the description of the board 1 2 4 Analog outputs The analog outputs of option
16. epends on the drive type used see the Table 5 on page 17 24 hour support 1 800 877 7545 Dial 2 Description of type B boards Siemens Industry Inc 17 3 1 2 Jumper selections On the OPTB1 board there are two jumper blocks The jumper block X2 is used to define the bidirectional terminal as either input or output The other jumper block X4 is used to connect the common terminals to GND The factory default and other available jumper selections are presented below Jumper Block X2 Jumper Block X4 DIO mode CMA CMB connection to GND cma ee cms ee CMA and CMB connection to GND CMA eo CMB eo g g g g g g DIO1 to DIO6 DIO1 to DIO6 mode OUT mode IN Factory Default Figure 5 Jumper positions for OPTB1 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 18 3 2 Board OPTB2 E s k N N N to N A Br o E og N o Description Type ID 16946 Terminals Jumpers None 3 2 1 I O terminals on OPTB2 Terminal Signal Parameter reference Description of type B boards I O expander board with a thermistor input and two relay outputs Three terminal blocks Screw terminals M3 No coding Table 6 OPTB2 1 0 terminals OPTB2 Technical information 21 RO1 normal closed Switching capacity 24VDC 8A 250VAC 8A 22 RO1 common DigOUT SlotX 1 23 RO1 normal open 125VDC 0 4A P Min switching load 5V 10mA Switching capacity 24VDC 8A 25 RO2 common
17. ernal short circuit protection on the control board NOTE Analog outputs and inputs do not work with only 24V supplied to the control unit If there is a 24V EXT 24V output on the board it is short circuit protected locally Should one of the 24V EXT 24V outputs short circuit the others would remain powered because of the local protection 1 2 6 Digital input signal conversions The active signal level depends on which potential the common input CMA is connected to The alternatives are 24V or Ground OV See figures 1 2 and 3 The 24 volt control voltage and the ground for the digital inputs and the common input CMA can be either internal or external Some typical input signal conversion examples are shown below If you use the internal 24V from the vari able frequency drive the following arrangements are possible 24 hour support 1 800 877 7545 Dial 2 General information Siemens Industry Inc 5 Jumper installed CMA connected to GND Figure 1 If CMA is connected to GND with inboard jumper the internal 24V is used and the CMA terminal need not be wired External 24V 24V EXT 24V Jumper not installed CMA isolated from GND Figure 2 Positive logic with external 24V when CMA is isolated from GND using onboard jumper The input is active when the switch is closed 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 6 General information x Jumper not installed CMA iso
18. hich is installed in the standard board slot The I O boards mounted at the factory are indicated in the type code of the variable frequency drive The expander slots D E for the Siemens BT300 are available for different option boards 1 2 Option board type B Type B option boards are used for I O expansion and are interchangeable with boards of the same type 1 2 1 Board type B technical data Table 1 Type B option boards technical data Safety all boards Analog inputs Al voltage Analog inputs Al current Digital inputs DI DC controlled Digital inputs DI AC controlled Auxiliary voltage output 24V Auxiliary voltage input ext 24V Reference voltage output 10Vref Comply with EN50178 C UL and EN60204 1 Inputs outputs galvanically isolated Isolation voltage rate 500V 0 10V R 200 Q single ended Resolution 10 bits 0 1 accuracy 1 of the full display 0 4 20mA R 2500 differential Resolution 10 bits 0 1 accuracy 1 of the full display 24VDC 0 10V 1 18VDC Rj gt 5kQ Control voltage 42 240 VAC 0 lt 33V 4 gt 35V 24VDC 115 max 250mA total summarized load from ext 24VDC outputs max 150 mA from one board 24VDC 410 max ripple voltage 100mV RMS max 1A In special applications where PLC type functions are included in the control unit the input can be used as external auxiliary power supply for
19. lated from GND Figure 3 Negative logic with external 24V when CMA is isolated with onboard jumper The input is active when the switch is closed OV is the active signal You can make the positive and negative logic arrangements also with the internal 24V Place the jumper block in the CMA isolated from GND position as above and wire the CMA terminal to the GND terminal of the variable frequency drive 1 3 Hardware protections 1 3 1 Terminal block coding In order to avoid incorrect connections of terminal blocks to boards some terminal blocks as well as related terminal connectors on the board are uniquely coded For more information see the description of the indi vidual board 1 4 Type identification number NOTE This information is relevant only for special applications designers using the Siemens NET tool Each Siemens BT300 OPTxx board has a unique type designation code Besides the type designation code each board has a unique Type identification number which is used by the system program to identify which board is plugged into the board slot The system program and the application use the Type ID also to establish the needed connections in order to achieve the desired functionality of the available I O boards in the control unit The ID code is loaded in the memory of the board 1 5 Defining functions to inputs and outputs programming The programming of digital inputs and outputs is very flexible There are no digit
20. n the OPTBF board there is one jumper block for selecting the analog output mode mA V The factory default and other available jumper selections are presented below ABCD AB CD ee age In AO1 mode AO1 mode Current Output 0 20 mA Voltage Output 0 10V BT3067 Factory Default 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 24 Description of type B boards 3 7 Description Supported sensors Type ID Terminals Jumpers 3 7 1 Board OPTBH L 0000000000 eee WG amp AO SKE _J rug la B e A ial wl EEE SE El D3 EE nl LILI 5 8 Sun 19 per Em M ol Se peu A 333 A gt a y mu 2 wa oe lili 158 er La MN LL smash Yi U BT3025 Temperature measurement board with three individual channels PT100 PT1000 NI1000 KTY84 130 KTY84 150 KTY84 151 16968 One terminal block Screw terminals M2 6 No coding None 1 0 Terminals on OPTBH Terminal Parameter reference Technical information Keypad 1 R1 1 Temperature sensor input 1 50 200 C 58 392 F 2 R12 Anin X 1 Accuracy 1 C 3 R1 3 4 R2 1 Temperature sensor input 2 50 200 C 58 392 F 5 R2 2 Anin X 2 Accuracy 1 C 6 R2 3 7 R3 1 o o Temperature sensor input 3 50 200 C 58 392 F 8 R3 2 Anin X 3 Accuracy 1 C 9 R3 3 y 10 INC 24 hour support 1 800 877 7545 Dial 2
21. ncy drive are noted Write the board type the slot in which it was mount ed and the date on the sticker Finally attach the sticker on your drive Product modified 9004 emf 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 14 Installation of option boards 24 hour support 1 800 877 7545 Dial 2 Description of type B boards Siemens Industry Inc 15 3 Description of type B boards The number of control inputs and outputs on your Siemens BT300 drive can be increased with the I O option boards This kind of boards can usually be placed in all option board slots inside the drive The boards you wish to have installed in your variable frequency drive have to be defined in the type desig nation code of the AC drive when ordering it from the factory I O board DI AI TI AO DO RO Other Board OPTB1 6 6 Programmable Board OPTB2 1 2 1 isolated 2 iso 24V Board OFTE mA lated mA EXT 24V Board OPTB5 3 5 Board OPTB9 5 1 42 240 VAC Board OPTBF 1 1 1 PT100 PT1000 NI1000 KTY84 130 Board OPTBH KTY84 150 KTY84 15 Table 4 Siemens BT300 option boards and their equipment DI Digital input AO Analog output AI Analog input RO Relay output TI Thermistor input DO Digital output 24 hour support 1 800 877 7545 Dial 2 Siemens Industry Inc 16 Description of type B boards 3 1 Board OPTB1 Jumper X2