Home
Grove Gear Worm Reducers User`s Manual
Contents
1. Electra Gear to maintain the warranty 1 Frequently check the oil level of the reducer If oil level is low refer to reducer vent and level position chart add proper lubrication through the filler plug until it comes out the oil level plug 2 Inspect vent plug often to insure it is clean and operating 3 Always check for proper oil level after filling Do not overfill or underfill with oil or injury to personnel reducer or other equipment may result 4 Do not mix different oils in the reducer Seals The Grove Gear Electra Gear line of speed reducers utilizes premium quality seals which are the state of the art in sealing technology Seals are however a wear item and eventually need to be replaced Replacement can be easily accomplished by following the steps below 1 Remove the worn seal without damaging the shaft surface or the seal bore This can be done by drilling a 062 diameter hole in the seal casing being careful not to drill into the bearing behind the seal Install a 10 sheet metal screw into the hole and pry out the seal 2 Clean the seal bore of sealant 3 Before installing the new seal use electrical tape to cover any keyways on the shaft to prevent seal lip damage 4 Grease the seal lips with bearing grease and apply a sealant to the seal bore 5 Slide the seal into the shaft being careful not to fold the inner lip over on any shaft steps 6 Press the seal into its bore with a sleeve that presses on
2. in whatever form Resellers Buyers will include the following language in a conspicuous place and in a conspicuous manner in a written agreement covering such sale The manufacturer makes no warranties or representations express or implied by operation of law or otherwise as to the merchantability or fitness for a particular purpose of the goods sold hereunder Buyer acknowledges that it alone has deter mined that the goods purchased hereunder will suitably meet the requirements of their intended use In no event will the manufacturer be liable for consequential incidental or other damages Even if the repair or replacement remedy shall be deemed to have failed of its essential purpose under Section 2 719 of the Uniform Commercial Code the manufacturer shall have no liability to Buyer for consequential damages Resellers Buyers agree to also include this entire document including the warnings above in a con spicuous place and in a conspicuous manner in writing to instruct users on the safe usage of the product This instructions manual should be read together with all other printed information suchas catalogs supplied by Grove Gear Electra Gear General Operation 1 Run the motor which drives the reducer and check the direction of reducer output rotation Consult motor nameplate for instructions to reverse the direction of rotation 2 Attaching the load On direct coupled installations check shaft and coupling alignment between spe
3. the seal casing being careful to keep the seal square in its bore GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Page 6 Class of Service Load conditions must be within cataloged ratings published in the current Grove Gear Electra Gear Catalog available upon request Published ratings assume lubrication with ISO 460 viscosity grade polyglycol PAG oil Contact Factory for ratings when an alternate lubricant is used Warranty From Grove Gear Electra Gear See 8050 catalog for warranty terms and conditions GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com MODEL B813 8100 Basic Unit Components SINGLE REDUCTION PARTS LIST Page 7 BASIC SINGLE REDUCTION UNIT supplied only when mounting B STYLE polion involves a Vertical shaft ITEM DESCRIPTION 129 OUTPUT COVER CLOSED HOUSING PIPE PLUG VENT PLUG SPLASH GUARD INPUT CAP O RING HEX HEAD CAP SCREW INPUT OIL SEAL INPUT BEARING cup and cone for 842 and larger units INPUT BEARING cup and cone for 842 and larger units RETAINING SCREW INPUT WORM SHAFT OUTPUT COVER OPEN OUTPUT COVER CLOSED O RING Complete information is available online GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com OUTPUT COVER SHIM as required OUTPUT OIL SEAL OUTPUT BEARING 18A CONE 18B
4. 28 248 325 584 800 1200 Extended Bearing N A N A N A N A N A N A N A 8 12 17 27 640 1008 1632 Worm Over on Secondary N A N A N A N A N A N A N A 192 308 320 485 805 114 1716 Unit of Double Reduction Stainless Steel WASHGUARD All 6 14 18 26 32 50 78 98 JN A N A N A N A N A N A Mounting Positions CAUTION Always check for proper oil level after filling Capacities vary somewhat with model and mounting position Oil should rise to bottom edge of level hole Do not overfill GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Page 5 Standard Gear Reducer Mounting Positions amp Vent Plug Level and Drain Locations A i LEVEL A DRAIN Worm Over DRAIN Vertical Output 5 fevered All primary units have their own oil level Double Reduction Worm Worm LEVEL H M Size 842 860 far side plug DRAIN Note High oil level applies to all size 842 amp larger DRAIN secondary amp tertiary units regardless of primary Vertical Input Worm Under P unit type A Does not apply to Stainless Steel WASHGUARD or units with Enviroseal option Maintenance Standard Units Your Grove Gear Electra Gear reducer has been tested and adjusted at Factory Dismantling or replacement of components must be done by Grove Gear
5. CUP HEX HEAD CAP SCREW OUTPUT SHAFT SINGLE OUTPUT SHAFT DOUBLE GEAR SPACER GEAR KEY only used on size 826 and larger units OUTPUT GEAR INPUT COVER KEY OUTPUT EXTENSION KEY INPUT EXTENSION NAMEPLATE VERTICAL SHAFT REQUIRED PARTS 130 OUTPUT COVER OPEN 131 OUTPUT BEARING GREASE RETAINER 132 GREASE FITTING 133 SEALED BALL BEARING only used on size 818 thru 826 units 134 INPUT COVER 136 INPUT BEARING GREASE RETAIN ONLY USED ON SIZE 842 AND LARGER UNITS ONLY USED ON SIZE 830 AND LARGER UNITS s SUPPLIED ONLY AS OUTPUT ASSEMBLY ON 813 THROUGH 824 UNITS Continued on next page QUILL MOTOR FLANGE UNIT BMQ STYLE 40 QUILL MOTOR FLANGE 41 INPUT OIL SEAL 42 HEX HEAD CAP SCREW flange to housing 43 RETAINING RING SHAFT 44 RETAINING RING HOUSING 45 QUILLINPUT SHAFT 46 KEY INPUT 47 HEX HEAD CAP SCREW motor to flange HOLLOW OUTPUT SHAFT UNIT H STYLE PARTS LIST cont d OUTPUT COVER OUTPUT OIL SEAL OUTPUT BEARING 53A CONE 53B CUP GEAR SPACER OUTPUT SHAFT SETSCREW GEAR KEY only used on size 826 and larger units OUTPUT GEAR 59 OUTPUT KEY LONG MOTOR FLANGE AND COUPLING KIT BM STYLE 110 C FACE MOTOR FLANGE Page 8 HEX HEAD CAP SCREW flange to housing COUPLING KEY REDUCER SHAFT SETSCREW REDUCER SHAFT COUPLING GEAR REDUCER SHAFT COUPLING SLEEVE SETSCREW MOTOR SHAFT COUPLING GEAR MOTOR SHAFT COUPLING KEY MOTO
6. R SHAFT HEX HEAD CAP SCREW motor to flange PLASTIC PLUG MODEL BM813 8100 Refer to Single Reduction Basic Unit Components MODEL BMQ813 8100 Refer to Single Reduction Basic Unit Components For the full Worm Gear Reducer Installation Lubrication and Maintenance instructions Visit Grove Gear website Phone 800 894 0412 Fax H HM HMQ Refer to Single Reduction Basic Unit Components A Regal Brand REGAL 888 723 4773 Web www clrwtr com Email info clrwtr com
7. Worm Gear Reducers Installation Lubrication and Maintenance Instructions Selection Information Read ALL instructions prior to operating reducer Injury to personnel or reducer failure may be caused by improper installation maintenance or operation Written authorization from GROVE GEAR ELECTRA GEAR is required to operate or use reducers in man lift or people moving devices Check to make certain application does not exceed the allowable load capacities published in the current catalog Buyer shall be solely responsible for determining the adequacy of the product for any and all uses to which Buyer shall apply the product The application by Buyer shall not be subject to any implied warranty of fitness for a particular purpose Safety Alert AWWARNING For safety Buyer or User should provide protective guards over all shaft extensions and any moving apparatus mounted thereon The User is responsible for checking all applicable safety codes in his area and providing suitable guards Failure to do so may result in bodily injury and or damage to equipment e Hot oil and reducers can cause severe burns Use extreme care when removing ubrication plugs and vents e Make certain that the power supply is disconnected before attempting to service or remove any components Lock out the power supply and tag it to prevent unexpected application of power e Reducers are not to be considered fail safe or self locking devices If these featu
8. ard with PAG lubricant this lubricant is not compatible with conventional mineral or PAO synthetic oils Special Lubrication Requirements Size 818 and Larger Units shipped from Factory are assembled to properly lubricate all internal components based on a spe cific assumed mounting orientation If a size 818 or larger unit will be mounted in an orientation different rom its original intension as shown in product catalog or run with sustained input speeds less than 1200 RPM it should be specified with the order The unit can then be modified to assure proper lubrication The precision made gears and bearings in Grove Gear Electra Gear Speed Reducers require high grade ubricants of the proper viscosity to maintain trouble free performance All standard reducers ordered rom the factory are filled with ISO viscosity grade 460 polyglycol PAG lubricant If oil needs to be added or changed ONLY compatible polyglycol lubricants should be used Contact the factory for more information Oil Capacities ounces Standard Units UNIT SIZE Mounting ___ Position 813 815 818 821 824 826 830 832 842 852 860 870 880 8100 Worm Over 4 12 12 20 24 40 56 72 112 188 312 560 768 1152 Worm Under 8 16 20 28 40 60 84 108 152 304 328 524 820 1280 Vertical Output 4 16 16 28 32 48 68 88 128 248 320 332 460 640 Vertical Input 4 16 16 24 32 48 72 92 1
9. ed reducer and loading mechanism On chain sprocket and belt pulley installation locate the sprocket or pulley as close to the oil seal as possible to minimize overhung load Check to verify that the overhung load does not exceed specifications published in the catalog 3 High momentum loads If coasting to a stop is undesirable a braking mechanism should be provided to the speed reducer output shaft or the driven mechanism A CAUTION The system of connected rotating parts must be free from critical speed torsional or other type vibration no matter how induced The responsibility for this system analysis lies with the purchaser of the speed reducer GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Page 3 Installation 1 Mount the unit to a rigid flat surface using grade 5 or higher fasteners The mounting fasteners should be the largest standard size that will fit in the base mounting hole Shim as required under flange or base feet which do not lie flat against the mounting surface 2 For shipment pipe plugs are installed in the unit and a vent plug is packed separately After mounting the unit in position remove the appropriate pipe plug and install the vent plug in the location shown on page 5 On double reduction units both the primary and the secondary must be vented Failure to vent the unit can cause premature seal wear or loss of seal and oil These conditions are not covered b
10. ning torque and the means of torque retention Lubrication Standard and WASHGUARD Platinum Units All standard reducers ordered from Factory are filled with Mobil Glygoyle 460 polyglycol PAG lubricant or equivalent suitable for continuous option within a 10 F to 120 F ambient temperature range Double and triple reduction units have separate oil sumps and must be filled checked independently Prior to startup verify that the oil is at the level shown on page 6 Lubricant type is stamped on all nameplates GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Page 4 Change Intervals Standard compounded lubricants non synthetic should be changed every six months or 2500 operating hours whichever comes first Factory installed synthetic lubricants should be changed only when performing maintenance that requires gearbox disassembly A CAUTION Oil should be changed more often if reducer is used in a severe environment i e dusty humid In the Food and Drug Industry including animal food consult the lubrication supplier for recommendation of lubricants which are acceptable to the Food and Drug Administration and or other authoritative bodies having jurisdiction Factory supplied PAG oil is acceptable for incidental food contact NSF H1 for use in and around food processing areas Do not mix different oils in the reducer Grove Gear Electra Gear reducers are shipped stand
11. res are required a properly sized independent holding device should be utilized Reducers should not be used as a brake e Any brakes that are used in conjunction with a reducer must be sized or positioned in such a way so as to not subject the reducer to loads beyond the catalog rating e Lifting supports including eyebolts are to be used for vertically lifting the gearbox only with no other associated attachments or motors e Use of an oil with an EP additive on units with backstops may prevent proper operation of the backstop Injury to personnel damage to the reducer or other equipment may result e Overhung loads subject shaft bearings and shafts to stress which may cause premature bearing failure and or shaft breakage from bending fatigue if not sized properly GROVE GEAR Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com Page 2 ACAUTION e Test run unit to verify operation If the unit tested is a prototype that unit must be of current production e If the speed reducer cannot be located in a clear and dry area with access to adequate cooling air supply then precautions must be taken to avoid the ingestion of contaminants such as water and the reduction in cooling ability due to exterior contaminants e Mounting bolts should be routinely checked to ensure that the unit is firmly anchored for proper operation Important Information In the event of the resale of any of the goods
12. y warranty Check for correct oil level Contact the Factory for level and vent recommendations on non standard mounting positions 3 Connect motor to speed reducer Depending upon gear geometry and operating conditions worm gear reducers may or may not back drive Use of a brake or external holding device is required if any evidence of backdriving is not desired Special consideration should be given to high inertia loads connected to the output shaft Consult the factory for further details AWARNING DO NOT CHANGE MOUNTING POSITIONS WITHOUT CONTACTING FACTORY Altering the mounting position may require special lubrication provisions which must be factory installed A CAUTION Do not operate the reducer without making sure it contains the correct amount of oil Do not overfill or underfill with oil or injury to personnel reducer or other equipment may result AA CAUTION A unit cannot be used as an integral part of a machine superstructure which would impose additional loads on the unit other than those imposed by the torque being transmitted either through a shaft mounted arrangement and any shaft mounted power transmitting device e g sprockets pulleys couplings A CAUTION For safe operation and to maintain the unit warranty when changing a factory installed fastener for any reason it becomes the responsibility of the person making the change to properly account for fastener grade thread engagement load tighte
Download Pdf Manuals
Related Search
Related Contents
+030220400 . Manuale .AC_nero UM10349 - NXP Semiconductors Agreement MESURES PHYSIQUES カタログ(5.7 MB) GUÍA DEL USUARIO Manual del usuario PDC301 ML UM GER.indd OPERATORTS MANUAL - Troy-Bilt GOVERNMENT OF TAMIL NADU LAPTOP COMPUTER SCHEME Copyright © All rights reserved.
Failed to retrieve file