Home
Installation and Instruction Manual
Contents
1. the procedure below to change input voltage There are 3 different voltage options for each receiver as shown in the picture 1 Switch off receiver power 2 Remove the connector from original position 3 Insert connector into the new voltage position accordingly r NOTE The Standard Voltages are 48V 110V 220VAC The default setting is 110VAC 10 Receiver Wiring Diagram INMOTION Controls 888 501 2220 MODEL 1242 SERIES RX COM 3 SOUTH 15 NORTH 1S S N 25 1 AC 1 SAS 34 3 MAIN IN 4 MAIN OUT L o o Lo o o o g o o COM 2 EAST 1S WEST 1S E W 2S CE 0470 FCC ID NCTO81K 11
2. If INMOTION Controls Inc Industrial Radio Remote Control mu Safety Reliability User Friendly February 2009 Contents Warning and Caution Warranty Important Information Before You Start Specification Transmitter amp Receiver Overview General Operation gt Getting Started gt Transmitter LED Indicator Changing Receiver Input Voltage Receiver Wiring Diagram Warning and Caution The following symbols may be found on the product or throughout the documentation Symbol A d z Description Refer to Manual Refer to the user manual for additional information when marked with this sign Dangerous Voltage Indicates the presence of hazardous voltage Unsafe practice could result in severe personal injury Warning Denotes a hazard Included text gives proper procedures Failure to follow instructions could result in severe personal injury and or property damage Caution Denotes a hazard Included text gives proper procedures Failure to follow instructions could result in minor personal injury and or property damage Warranty Warranty INMOTION Controls Inc guarantees that this equipment meets its published specification at the time of shipment from the factory This equipment will perform as described if installed properly However INMOTION cannot guarantee that operation in INMOTION Series 1242 is absolutely error free or without interruption Warranty Period Th
3. is equipment is warranted against defects in materials and workmanship for a period of one year from the date of shipment During the warranty period INMOTION is responsible for necessary repairs as long as the product can be proven to be defective For warranty service or repair this equipment must be returned to a service facility designated by INMOTION Customer is responsible for shipping charges to INMOTION while INMOTION will pay the return shipping charges Excluded Items This warranty does not include consumable parts such as Joy stick batteries fuses buttons and relays Also this warranty does not cover defects caused by improper installation improper or insufficient maintenance unauthorized modification unavoidable natural essential improper operation ignorance of environmental specifications improper software interfacing Remarks 1 No other warranty is expressed or implied except for the above mentioned 2 The remedies provided herein are the buyer s sole and exclusive remedies INMOTION shall not be liable for any direct indirect special incidental or consequential damages Important Information Before You Start Important 1 Read this manual carefully before operating and installation 2 Due to the complex nature of equipment it is necessary to read the entire manual before installation 3 Never allow any unauthorized personnel to dismantle equipment as this may cause equipment damage 4 The equipmen
4. na 2 Power On Indicator Alarm Horn 4 Receiver Wiring Diagram Cable General Operation Getting Started 1 Install 4 new AA size batteries in the battery compartment make sure batteries are correctly installed according to Positive amp Negative and close the battery cover firmly 2 Insert rotary key into transmitter unit and switch to ON position 3 Press START button to power on the system Note Red LED indicator will flash if this procedure is not followed accordingly 4 Press function button for operation Follow the procedure below when finished with operation 1 Press EMS button 2 Switch rotary key to OFF position 3 Remove rotary key and keep in a safe place 4 Remove batteries if not to be used for a long period of time Transmitter LED Indicator Green Full Power Yellow Mid Power Unload the article as soon as possible and stop operation until old batteries are replaced with fresh batteries Red Low Power An EMS signal will be sent to the receiver automatically to turn off receiver To avoid interruption during operation check battery power frequently NOTE Switch rotary key to OFF position to turn off transmitter completely thus extending battery life otherwise transmitter is in standby mode when rotary key is in the ON position Changing Receiver Input Voltage If the factory preset receiver voltage is different from application follow
5. rd operating procedure and maintain system regularly Check EMS button and other system main functions before operation Press EMS button during system failure or when any abnormal conditions occur The operator must be familiar with emergency procedures before operating the system Emergency Procedures In case of emergency please follow the procedure below l 2 3 4 Press EMS button and stop operation Switch rotary key to OFF position and remove it from transmitter unit Switch off crane main power Contact the authorized distributor for further assistance Specification General Specification Operauns Channel oido liana liana 70 Channels IDC NTN Over I Million Sets Channel Space ee AR NA DA A AO OO ai 25 KHz Hammons Distance gt 4 SIC alla Enhanced Glass Fiber Operating Environment 40 F 185 F Operatme Distance Up to 300 Feet Transmitter POW EL erorcen UR TNT 4 AA Batteries Emast POSWGE un dada teo er do JOmW DIMENSIONS i hh dob ene ACE a le 10 79 x 3 03 x 1 65 VS CUI sam ea RR E O E 0 848 Ibs Receiver POWEL ee AE IDE ver Eee E op e Ee 24 48 110 220V AC 420 DIMAS D SIOMS zee TT 12 20 x 6 30 x 3 74 WY Cle MU ac conte ca TTE 6 39 Ibs Transmitter amp Receiver Overview INMOTION Series 1242 Transmitter Overview EMS Button LED Indicator Function Button amp A B Switch START Alarm Button Battery Cover 6 Rotary Key INMOTION Series 1242 Receiver Overview Anten
6. t has been stringently tested for quality assurance before delivery from factory However it must not be used in extremely dangerous situations or where damage may result 5 After operation switch off crane main power as well as receiver unit and remove rotary key from transmitter unit 6 Keep the transmitter in a safe place when not in use to avoid any unintentional operation 7 The crane should be equipped with a main power relay limit switch and other safety devices required 8 Do not use this device during an electrical storm or where there are conditions of high electrical interference 9 Always check transmitter batteries and receiver input power condition before operation 10 The installation and maintenance service is allowed only when the crane and receiver power are off to avoid electrical shock 11 The contents of the manual may be amended by the manufacturer without notice 12 The specification and function is subject to change without notice by manufacturer Precautions l Press EMS button and switch off main power of crane and receiver after operation Then remove transmitter rotary key and keep in a safe place The following situations may cause receiver response delay and stop operation immediately when situation occurs a Beyond operating range b During severe radio interference Remove transmitter batteries when not in use for a long period of time To extend product life please follow the standa
Download Pdf Manuals
Related Search
Related Contents
Décision n° 2010-1312 Lincoln Electric SAE-400 User's Manual 価格と発売日 『inpresX RMX(リミックス)』開発の背景 Fisher-Price H4807 Instruction Sheet PWO-480 INSTALLATION MANUAL 全自動血圧計 取扱説明書 METALIEN iAXE629 USB-GUITAR Pioneer XW-NAC1 Copyright © All rights reserved.
Failed to retrieve file