manual with circulation pump
Contents
1. xe 220Va c mem Ws w iiS b M MI Je zs s N ae WA TO AUR y 9 K190 lke YBoARD KEYBOARD s oll N J un ay A 4 J P 9 ITE li PFS S Rir PA 3 913 4 J 20A 2 S a v18 x 5 Kul 12Vac cio E k 4 cz 5 LS 3 Ahh WI H 38 CC a sn 3 af NNONO0E a kae NU S oco jicr viz eS g R5 485 S zil T Kas ooo 1c2 aC v A w Ws a is NG z gt s Eia m COM Ks k Sla L1 us iz I 2 MD S pE L2 Mi KI Re Ka E EZ o o PZ ue cis 4 kis a me L3 i mae mio cis 7 nem g m u z 3 misa a AN PES ok wise For 9 D I mis Eimi LI Jo els NGA ove NY s NGA ave A 5 RL L2 N L3 i B i AsTRE Sa z GD 7 HEATER cso5091 L
2. C The following 3 pages will show you the possible connection for this configuration Please notice the difference between high and low current and the way the heater is connected 2 1 kW 3 3 kW 5 2 kW Also pay extra attention during when connecting the spa to the following matters The right connection according to the available power in combination with the specification of the spa Wires from board to heater are connected in the right way for this specification Dip Switch SW1 is in right position for this specification Low or High Current All wires and bridges are in accordance these drawings between connection M5 M6 M8 M9 and M11 FN 4SeasonsSpa 8 User manual EasyTop Laing heater Power Supply 1 x 20A LC Low Current Configuration To have this configuration you have to put the first dip switch in position ON down Heater is working at 2 1 kW Phase Neutral Ground OPAZZLLLLLL LLL 4SeasonsSpa Heater Ground Power Supply 1 x 32A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF up Heater is working at 2 1 kW M9 M6 ee L1 L1 L2 L2 M11 Neutral HEATER Ground OZ L R C v2 Heater Ground Heater Phase Heater Neutral Heater Neutral Heater Phase User manual EasyTop Laing heater 4SeasonsSpa Power Supply 2 x 16A HC High C
3. Fig 2 1 4SeasonsSpa 5 User manual EasyTop Laing heater 4SeasonsSpa 4 The filter cartridge s must be placed in the opening of the skimmer e Remove the outer section with the skimmer frame by sliding it upwards e Remove the tray for the collection of coarse dirt and leaves slide forwards Place the filter with the thread downwards in the opening and tighten it with a few turns Do not turn too tightly as it can damage the thread 5 Ensure that all three gate valves red handles refer to fig 2 1 in the machine compartment are open slide upwards The spa has been delivered to you in this condition The transparent tubes around this valve ensures the valve cannot close on its own A closed valve is only necessary when performing maintenance on the pumps or controls 6 Ensure the tap drain is closed and that the plug is in place refer to figure 5 1 7 Fill the spa with tap water up to the level indicated on the skimmer Do not overfill the spa the water level will still rise when somebody uses the spa Do not use rain or surface water to fill the spa Ensure the water level is always on or around the indicated level on the skimmer A water level that is not sufficiently high will cause air to enter the pipes and the pump which voids the warranty It is recommended that a garden hose is used to fill the spa through the skimmer This will facilitate starting the pumps as it will automatically remove air from the plumbing 8 Check th
4. a week before each spa use of the water is necessary for the following parameters a pH value between 7 0 and 7 5 b Free chlorine value must be at least 1 5 mg l c Bound chlorine should be at most 0 2 mg l d total alkaline value should be between 80 and 120 ppm To test for these values use a reliable testing kit and record the values in a log book This way you can get a good view of the manner in which the water is treated and used The ESWA recommends replacing the water every two months if the spa is in standby If the spa is used more often the water should be changed more regularly NEVER USE CHLORINE TABLETS TRI CHLORINE THE ONLY FORM OF CHLORINE ALLOWED IS IN POWDER FORM DI CHLORINE IF YOU DO USE CHLORINE TABLETS THIS WILL VOID THE WARRANTY ON THE SPA COMPLETELY AND ENTIRELY 4SeasonsSpa 18 User manual EasyTop Laing heater 4SeasonsSpa 5 Draining the spa Follow the instructions for one of the methods given below when the spa is to be emptied Method 1 e Turn power OFF at the breaker e Locate the drain valve Fig 5 1 located in the mechanical room e Remove the safety cap and attach a garden hose Turn outer ring counter clockwise and pull outward on the garden hose This will open the drain valve fully Drain water to a convenient area Spa water may harm grass or plants if sanitizer levels are high e When water begins to flow out of the hose open the air relief valve located on filter lid e Yo
5. at filter and heat 1 Press the Filter Purge button until you see F or FD in the display After that please use the Up and Down buttons The duration of the filtering cycle and the time for running the first cycle can be selected according to requirements the remaining cycles follow at 12 hour intervals F duration FD delay of the starting time duration of the filtering cycles The duration of the filtering cycles can be set from 0 filtering disabled to 12 hours continuous filtering with 1 hour steps setting the delay of starting time To set the time when the first filtering cycle is run set the hours remaining from the moment of programming to the start of the filtering cycle Below is an example Programming at 14 00 a three hour filtering cycle needs to be run starting at 19 00 Calculation of the delay until start 19 00 14 00 5 hours On the keypad set the duration of the filtering cycle 3 hours and the delay until start in this case 5 hours The overall effect will be that the first filtering cycle lasting three hours will start at 19 00 the next at 7 00 and the next at 19 00 etc Note if the delay to start is set to 0 the filtering cycle starts immediately 4SeasonsSpa 14 User manual EasyTop Laing heater 4SeasonsSpa 3 3 Heating When the water temperature reaches 0 5 C lower than the set temperature the heater will automatically be activated until a temperature 0 5 C above the desi
6. electrician e Observe local rules and regulations consult your electricity supplier or an electrician e Do not connect the spa to the power supply if the spa does not contain water e A fixed connection through a separate current group is required for the connection to the power supply No other equipment must use this fuse e This current group must have a RCD or grounding switch 30 mA must have been included in the circuit 4SeasonsSpa 7 User manual EasyTop Laing heater 4SeasonsSpa Low current High Current Depending on the available power it s possible to switch between Low Current LC and High Current HC In the HC position the heater is always working when heat is needed In the LC position the heater is only able to heat when pumps are running on low speed When pumps are in high speed the heater is switched off After switching off high speed again the heater starts automatically heating In Low Current the heating icon in the display will flash when heat is needed but the heater is not able to heat because of Low Current When icon is solid the heater is working You are able to switch between LC and HC with Dip Switch SW1 on the board of the control box Dip Switch SW1 OFF High Current ON Low Current
7. first modifiable parameter will be displayed Pressing the Filter Purge button again moves to the next parameter saving the value of the current parameter The value of a parameter can be changed using the Up and Down buttons Pressing the Filter Purge button after the last parameter has been accessed reset the system and the new settings become effective Software 367 Functionality ie key for 20s 1 parameter will appear Up Down keys modify Duration Press Filter key to display next parameter System will reset after last parameter Display As table below Default values in bold Parameter Display Value Meaning Light LI x 1 single intensity 2 Light with two intensity levels Remote heater RH x 0 None 1 Remote heater On Filtering FC x 1 Filtering cycle 2 Purge cycle Clean filter warning CF x B Disable 1 Enable O No water level Level sensor H20 x 1 Indicate only 2 Close outputs Water level debounce time Ld x BSS second 1 25 seconds 1 On when heating amp filtering CIrculatlon Bump CPK 2 Always ON 24 hours a day Clean Filter warning CF x A message appears to remind the user of the need for maintenance on the pool filters In this case the message CLE or CF will be displayed every two weeks flashing on the main keypad to indicate the need to clean the filter Pressing any button cancels the warning from the display
8. for products and instructions If you have an Ozonator supplied with your spa do not rely on it completely always add a small amount of chlorine or other kind of suitable steriliser in order to make sure that the water is completely sterilised The spa may become wet and slippery and has sharp or non yielding parts Ensure therefore that you know how to enter and leave the spa safely before you start using the spa Always ensure someone is present to offer assistance should the user of the spa encounter difficulties due to injury cramps or drowning this is especially important when children use the spa Prolonged immersion of your entire body including the head can have deleterious effects on your health WARNING do not install the spa On any floor above ground level without permission from the owner builder of the unit On a balcony without permission from the builder of the building Underneath or next to power lines or close to underground electrical equipment consult an electrician when in doubt In a location that introduces the risk of water damage to your spa Your spa is designed for outdoor use only If you use your spa indoors or in any kind of building then you do so at your own risk The manufacturer or dealer will not be held liable for damages caused by leaking whatsoever and howsoever caused 4SeasonsSpa 4 User manual EasyTop Laing heater 4SeasonsSpa 2 Installation instructions Check the packaging and t
9. match the drawing Recommended setting e Augusta and Julia 2 1 kW Laura Sophia and Flora 3 2 kW WARNING This device contains live electrical components Consequently all the service and maintenance operations must be performed by expert and qualified personnel after having taken the necessary precautions IMPORTANT Read this paragraph carefully before connecting the spa If you do not follow the instructions provided in this paragraph the spa pack and other electrical equipment may be severely damaged 2 1 kw e Single phase 230 V 50 60 Hz 20 A low current connection e Single phase 230 V 50 60 Hz 32 A high current connection e Double phase 230 V 50 60 Hz 2 x 16 A zero grounded 2 x 16 A high current connection 3 3 kW e Single phase 230 V 50 60 Hz 32 A high current connection e Double phase 230 V 50 60 Hz 2 x 16 A zero grounded 2 x 16 A high current connection 5 2 kW e 400 V 50 60 Hz 3x 16 A zero grounded 3 x 16 A high current connection The unused connections of the control box can let water flow through For safety reasons and to prevent personal injuries and material damage these connections should be covered with approved covers This way the inside of the control box will not come into contact with water that is splashed etc This has to be performed by a certified electrician e The electrical connection of the spa must only be performed by a certified
10. Filtering FC x Your spa is equipped with 2 jet pumps and a circulation pump Most people install their circulation pump to work 24 hours a day In this case you are able to set a PURGE cycle The circulation pump is working 24 hour a day and you can set 1 2 3 4 6 8 12 or 24 times a day a 1 minute purge cycles During a purge cycle the 2 jet pumps will run on high speed For example when you press the purge button on the display the message is P When you program 24 hour cycles the spa will have each hour a 1 minute purge cycle 4SeasonsSpa 22 User manual EasyTop Laing heater 4SeasonsSpa The table below lists the specifications of the outputs available It also shows the connections on the board and their function for each output External connector Connection 4SeasonsSpa Output Voltage current Strain relief Board connections function AN J11 1 HI Brown J11 2 N Blue P aa Pump1 2 speed 230VAC 6 5 FLA TO M20 311 3 Lo Black Low speed J11 4 Yellow Green Sroung J13 1 HI Brown High speed J13 2 N Blue Neutral Pump2 2 speed 230VAC 6 5 FLA M20 313 3 Lo Black Low speed J13 4 Yellow Green Ground PrF J12 1 L Brown Phase Pump3 1 speed 230VAC 6 5 FLA M20 J12 2 N Blue Neutral J12 3 Yellow Green Ground LAN Ji 1 L Brown Phase Blower 230VAC 6 A M20 J1 2 N Blue Neutral J1 3 Yellow Green Groun
11. MANUAL s AAA AA eo a Ak 7 AS Na J WYA A gt TOSA EasyTop Laing heater circulation pump with 2 jet pumps ALL SPA MODELS User manual EasyTop Laing heater 4SeasonsSpa About this manual This user manual contains information which will allow you and your family to enjoy your spa for years to come It is imperative for you to read the entire manual and adhere to all safety instructions before filling the spa and connecting it to the power supply This manual is an integral part of the product and therefore must be kept for future reference along with your warranty Chapter 1 Safety information Chapter 2 Installation instructions Chapter 3 Spa Operation Chapter 4 Using the Spa Chapter 5 Draining the Spa Chapter 6 DIP SWITCHES and LOW LEVEL configuration Chapter 7 Problem solving 4SeasonsSpa User manual EasyTop Laing heater 4SeasonsSpa 1 Safety information 1 1 Private Use This spa should only be used for private use 4SeasonsSpa does not provide any warranties for use in public or commercial locations 1 2 Electricity and Electrical Shock Risk The installation of the spa and any repairs to its electrical components must be performed by a certified electrician Do not place any electrical appliances within in or within 1 5 meter around the spa Precautions regarding the risk of electrical shock e Non earthed metal objects must not be present within an area of 1 5 m ar
12. ake sure that the spa is installed a few centimetres above the level of the balcony or floor to ensure that no water will remain under the spa during or after a rain shower The ventilation of the frame is important for its life span There should be at least 10 centimetres of free space around the spa to allow for the ventilation of all the side panels Therefore never place a spa right against a wall e If you sink your spa into a deck or hole in the ground then you should make sure that the area around the spa is properly drained Customers who do this do so at their own risk You may have to arrange for the spa to be lifted out of the ground or deck at your own cost in the event that maintenance is required 2 2 Filling the Spa with Water 1 Ensure that the electrical cord is outside the spa and has NOT YET been connected to the power supply 2 Check the spa to ensure there is no damage that may have occurred during shipment Make a note of any damage possibly take pictures and notify your supplier immediately 3 The spa has 4 connections 2 on each side of both pumps These connections may have been loosened during transportation Tighten the 4 connections manually The points that need to be checked are indicated in the photographs below Fig 2 1 If these connections continue to leak after tightening we recommend applying acid free Vaseline to them If dehydration causes leakage in the future applying Vaseline is also recommended
13. ally deactivated Pump 2 e Press Pump 2 key to turn Pump 2 on at high speed e Press a second time to turns Pump 2 off A built in timer automatically turns Pump 2 off after 20 minutes unless it has been manually deactivated Note 1 If the system is running in smart winter mode i e the pump is running at high speed and you press the pump 1 key the cycle will be cancelled and the pump will start running at low speed Lighting e Press the light switch to turn light on in bright mode e Press a second time to switch to lower intensity lighting e By pressing the light switch a third time the light will go off e A built in timer automatically turns the light off after 2 hours unless it has been manually deactivated Water Temperature e The display shows the current water temperature e By using the arrow keys you can adjust the water temperature to the desired temperature The newly selected water temperature will be shown on the display for five seconds confirming the new settings After this period the display will start to show the current temperature again The EasyTop controller can be used to set the water temperature to a value between 15 and 40 C The temperature can be adjusted using the arrow keys on the control panel The water is heated by the heater located in a metal tube around the yellow control box in the technical room of the spa If the water temperature is too low the controller initiates the follo
14. con Solid Blinking A Pump 1 active at high speed Pump 1 active at low speed IA A Pump 2 active at high speed 4 Display shows desired temperature Heater not active but heat required Low g Heater active Current connection b AN pen Light on at high intensity Light on at low intensity q Economy function active Economy function in stand by aii Filter or Purge function active Filter or Purge function in stand by 3 1 Activating the control system display Check the following before operating the spa Ensure the spa is filled with water Ensure all valves are open Ensure the water flow through the pipes is not obstructed The temperature of the water used to fill the spa is in general lower than the standard set temperature of 36 C The controller will therefore as soon as it is switched on activate the circulation pump which will push the water trough the heating system and automatically activate it The circulation pump is set to run 24 hour a day 4ASeasonsSpa 12 User manual EasyTop Laing heater 4SeasonsSpa Pumps This spa has 2 pumps both single speed pumps The pumps are connected and operated through the control box and you can switch them on or off using the display Fig 3 1 Pump 1 e Press Pump 1 key to turn Pump 1 on at high speed e Press a second time to turns Pump 1 off A built in timer automatically turns Pump 1 off after 20 minutes unless it has been manu
15. country has its own rules about water treatment 2 Take into account the directions given by your dealer Local dealers are familiar with different water treatment products specific to your region and water type Make sure you are properly informed 3 Ensure proper information is provided on the chemicals being offered Ensure the provided chemicals can be used for the water treatment in your spa and that they are allowed in the country you will be using your spa in Very important 4SeasonsSpa is not responsible for the water quality in your spa as this is entirely dependant on water treatment and water quality 4 To fill your spa only use regular tap water 5 As soon as the spa is filled begin water treatment The filtration mechanism has to be on continuously which requires constant current to be available 6 Test the pH value of the water and adjust if necessary Keep the pH between 7 0 and 7 5 At this pH value disinfecting products will work best The total alkaline value should be kept between 80 and 120 ppm mg l Record the values in a log book for your records 7 Free chlorine should be kept at a minimum of 1 5 mg l 8 Every two months the night before draining the spa add some Anti scale to your spa water and leave it to run overnight This will remove any lime scale from your pipes and pumps The manufacturer is not liable for replacing pumps which have seized up due to lime scale build up A regular checkup at least twice
16. d ga J7 1 L Brown Phase Circulation Pump 230VAC 1 FLA M20 J7 2 N Blue Neutral wt J7 3 Yellow Green Ground AN J8 1 L Brown Phase Ozone Generator 230VAC 1 A p9 M20 J8 2 N Blue Neutral NGGI J8 3 Yellow Green Ground J9 1 L Brown Phase Aux1 230VAC 1A J9 2 N Blue Neutral J9 3 Yellow Green Ground J10 1 L Brown Phase Aux2 230VAC 1A J10 2 N Blue Neutral J10 3 Yellow Green Ground Light 12 VAC 2A J3 MTA 100 J2 1 L1 Brown Phasel 230 VAC 1x16A i a J2 2 L2 Black Phase2 Power Supply 230 VAC 2x16A t M32 J2 3 L3 Grey Phase3 230 VAC 3x16A V J2 4 N Blue Neutral J2 5 Yellow Green Ground J4 L2 Brown Phase 1 phase Heater 230 VAC 16 A J5 N Blue Neutral M13 Yellow Green Ground J4 L2 Brown Phase1 2 phases Laing Heater 230 VAC 16 A ee Aaa M13 Yellow Green Ground 23 User manual EasyTop Laing heater 7 Problem Solving 4SeasonsSpa Signal on the display Possible causes Actions Not a malfunction bie de as pack signals a previous power e Press any button ailure The system has switched off the e DO NOT ENTER THE SPA heater because the temperature at e Switch the pack OFF then wait for the water to cool HL steady the heater has reached 48 C down 119 F e If the problem persists refer to the troubleshooting DO NOT ENTER THE SPA manual or contact the technical service The system has switched off the e DO NOT ENTER THE SPA seki akak an a pal e Switch
17. e 4 connections discussed in section 2 2 part 3 for leaks while filling the spa If you detect some moisture you should attempt to teithen them a little more or use more acid free Vaseline If leaking persists contact your dealer If the pumps are on but there is no water movement in the spa then it is likely that air is present inside the pumps You can remove the air by loosening the air valve Fig 2 3 As soon as water starts to run out when pump is off you can fasten it again Do not over tighten this bleed valve if it snaps off through over tightening then you may have to replace the pump It is recommended to do this after you have run the pump five times for duration of 20 seconds Between attempts wait one minute 4SeasonsSpa 6 User manual EasyTop Laing heater 4SeasonsSpa 2 3 Connecting the Spa to the power supply e Fill the spa with water as described in 2 2 e Hire a certified electrician to install your spa Laing heater with circulation pump Your spa contains a Laing heater with a circulation pump These parts take care of filtering and heating of the water Depending on the available power your Laing heater can heat at 2 1 kW 3 3 kW or at 5 2 kW This heating element has 3 wires black blue and brown by connecting them in a different way on the board the power to the heater will change Please check carefully the way the heater is connected on the board and pay attention that the colours of the wires will
18. ed e Ifyou have adjustable jets they can be turned in the desired direction e Itis normal for persons who are using the spa to regularly change location to enjoy the various massage options at the various sitting and or lying positions depending on the spa type e Position the cover on top of the spa after use This will have an insulating effect and will prevent children from entering the spa accidentally 4 3 Regulating the Jet power The pumps force a large amount of water through the jets It is possible to add more force to the jet by adding air to the water The air supply is regulated using 4 air valves controls two for each pump Turn the tap to the left to open the air supply or to the right to close the air supply You will only see an effect when the pumps are operating at high speed The air valves are the small turning buttons The 2 diverters can be used to distribute the massage jet evenly or towards the left or the right of the spa Each pump has its own diverter which can divide the output of the pump over two groups Using these diverters the desired massage intensity can be set It is best for the diverter to turn the pumps off while setting it in the right direction The force required to move it will be far less when it is not operational It is beneficial to grease the inside of the diverters with acid free Vaseline this will keep them moving more smoothly Fig 4 2 Neck jets If the spa is equipped with
19. er to grease them with acid free Vaseline They are easy to open when they need to be detached On the inside you will find a black rubber ring which has to be properly greased e Also clean the white plastic part in the diverter or air valve and apply also some acid free Vaseline Hard water lime will inhibit smooth turning of the diverters and air valves Not all jets are working e Ensure all pumps operate at high speed e Ensure all diverters are in the intermediate position so all jets receive adequate water e Ensure all jets are open it is possible to open and close each jet separately Water comes out of the jets intermittently e Check the water level if it is too low the skimmer takes in air which interrupts the water flow Fill the tub to the indicated level on the skimmer Service In case of problems first contact your own dealer after which the following contact address is available 4SeasonsSpa Herengracht 444 1017 BZ Amsterdam The Netherlands info 4seasonsspa com www 4seasonsspa com 4SeasonsSpa 25 User manual EasyTop Laing heater 4SeasonsSpa 4SeasonsSpa 26
20. ered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes Immersion in water that is too hot may cause your body temperature to rise by a few degrees from the normal body temperature of 36 6 C This is referred to as heat stroke Heat stroke occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature The symptoms of a heat stroke include drowsiness lethargy fainting and dizziness The consequences of not being fully aware of the potential dangers associated with heat stroke may increase the risk of drowning Do not remain in the Spa for a period exceeding 20 minutes when the water temperature is equal to or exceeds 37 C If you wish to remain in the Spa for longer periods of time set the temperature equal to body temperature 36 C 1 6 Pregnancy Since excessive water temperatures have a high potential for causing fatal damage during the early months of pregnancy pregnant or possibly pregnant women should limit water temperatures to 36 C and limit immersion in the spa water to 10 minutes at a time If pregnant please consult your physician before using a spa 1 7 Accurate thermometer Before entering the spa the user should measure the water temperature with an accurate thermometer to rule out possible errors on the display 1 8 Use of Alcohol Drugs and Medication Do not use drugs alcohol or certain medicatio
21. he dip switch has two possible positions ON toward down OFF toward up The tables shown below describe the function of each individual switch based on the type of software installed The preferred settings for your spa are in bold Software 367 N switch Position ON Position OFF 1 Low Current High Current 2 10 button keypad 8 button keypad 3 Blower installed Blower not installed 4 Pump 1 one speed Pump 1 two speed 5 Pump 2 one speed Pump 2 two speed 6 Pump 3 installed Pump 3 not installed 7 Circulation pump installed Circulation pump not installed 8 Ozon active during filtering Ozon always on Once having modified the position of the switches on the dip switch close the cover on the pack and reconnect power only then will the modifications become operational ATTENTION do not change the positions of the switches without first having disconnected the power supply to the pack As well as the risk of electric shock the switches settings become operational only after power has returned These dip switches setting are always in combination with the low level program which we will explain on the next page 4SeasonsSpa 21 User manual EasyTop Laing heater 4SeasonsSpa A certain number of parameters can be configured on the EASYToP pack from the main keypad display To access the low level programming mode press and hold the Filter Purge button for 20 seconds after this time the
22. he spa for damage Inform the carrier and supplier immediately if you detect any visible damage The spa is delivered in an upright position on a pallet The front panel of the exterior portion of the spa is located on top of or on the side of the spa underneath a strong layer of silver coloured foil Thus the wooden exterior portion of the spa is packed separately Remove these before dropping the spa The panel has been packaged in this fashion to prevent transportation damage to it due to water leakage The front panel can be secured by using the 6 screws supplied with the spa and located within the technical room with tape connected to one of the tubes The holes to attach the lower panel have been pre drilled 2 1 Location Your new portable spa must be placed on a firm flat and level surface so the spa weight is supported uniformly We recommend a concrete slab or the equivalent Uneven flooring can damage the spa and voids the warranty The base must meet the following requirements e Strong The base surface must be strong and capable of supporting a weight of at least 370 kg m2 Horizontal A horizontal surface is of critical importance A flat and horizontal base will ensure that the weight is distributed equally It is of critical importance that the entire surface of the spa is supported e Dry and well ventilated The spa has to be installed on a dry surface In other words the frame of the spa should not be in contact with water M
23. n before or during spa use If combined with bathing in hot water it may lead to drowsiness or loss of consciousness resulting in an increased risk of drowning Drinking alcohol and using drugs or certain medication in the spa may increase the risk of a fatal heat stroke Consult with your physician before using a spa if you are taking medication Sedatives narcotics antihistamines or medication for your blood can cause drowsiness and nausea or influence your blood pressure 4SeasonsSpa 3 User manual EasyTop Laing heater 4SeasonsSpa 1 9 1 10 Safety precautions Do not use the spa if you suffer from an infectious disease Do not use the spa immediately following strenuous exercise Bathing in high temperature water may lead to temporary changes in the circulatory system such as subcutaneous vascular dilatation Therefore we recommend consulting a doctor before using the spa if you suffer from obesity heart disease a blood pressure that is too low or high blood circulation problems or diabetes Do not overflow your spa Overflowing your spa will invalidate your warranty as it can cause damage to the electrical amp mechanical parts of the spa Other Safety Measures Do not use glass or other breakable objects in or around your spa eg beer bottles Do not remove any parts from the spa Keep the water clean and pure use spa specific products to destroy harmful bacteria and to prevent algae growth consult your local spa dealer
24. neck jets at one of the seats then these can be activated by turning the handle nearby the seat to the open position This button looks like an air valve To use these neck jets the seat has to be in use by running the pump and the appropriate diverter to send the water to that particular seat 4SeasonsSpa 16 User manual EasyTop Laing heater 4SeasonsSpa 4 4 Filtration As explained earlier we recommend allowing a 24 hour circulation The circulation pump has a small flow of water so there needs to be enough time during a filter cycle When you do not install a 24 hour circulation cycles we recommend at least a filter cycle of 2 x 6 hours BOOST FILTRATION If the water could benefit from additional cleaning for example after heavy use or addition of chemicals it is possible to activate the BOOST FILTRATION function By pressing and holding the pump 1 button for five seconds pump 1 will be activated and filter for 40 minutes at high speed while the ozonator is activated as well BOO will be indicated on the display After 45 minutes the spa goes back to its regular settings 4 4 1 Filter Cartridge Clean the filter cartridge every week by rinsing it with a powerful water jet In the LOW LEVEL setting a warning can be activated that displays a clean filter CF warning on the display every week By pressing any button this warning is removed It is recommended to renew the filter cartridge every year Your spa dealer will be able to pr
25. oom If the temperature passes below a threshold of 6 degrees Celsius both pumps will be activated and run at high speed for one minute The filtration icon on the screen will blink The frequency of this cycle is dependant on the temperature in the technical room irrespective of the water temperature in the spa which will be kept above 15 degrees at all times 3 9 Power UP signal The Power Up function is used to notify the user that a power failure has occurred If the current water temperature flashes on the display alternating with the time if available it means that a power failure has occurred Pressing any button makes the information shown on the display come on steady 4SeasonsSpa 15 User manual EasyTop Laing heater 4SeasonsSpa 4 Using the Spa 4 1 First time use Check the following before turning the spa on for the first time Ensure there is sufficient water inside the spa Ensure the appropriate valves are open in the mechanical room 4 2 Using the spa Generally the temperature of the water used to fill the spa will be lower than the desired water temperature for use 36 C For this reason when started the controller will start heating the spa While you are inside the spa it can be activated in the following manner e First turn on pump 1 at high speed by pressing the pump 1 button once and then the pump 2 button e Check if all jets are open by turning the end of the jets they can be closed or open
26. ound the spa e Electrical household equipment and electrical tools must not be present within a radius of 1 5 m around the spa Examples of these are lighting telephones radios e The electrical supply to the spa must be protected by a RCD earth tripper switch 1 3 Child Safety Children should not use the spa without adult supervision e Install a self closing or lockable door or gate a fence or a child safety gate e Secure the supplied cover on the spa when not in use including children safety locks 1 4 Filter filter components and suction force The first plastic leaf filter which is present in the skimmer square opening with cover located at the half way point of the water level covers entry to the pumps and plumbing Serious accidents may occur should long hair or limbs be sucked by the pump into the supply pipe This can only occur if the filter is faulty or missing Preventing injuries e A faulty or missing filter or cover plate in the first filter must be replaced immediately e The first filter in the spa is geared towards the suction force of the installed pump Check whether the first filter and the pump are compatible when one of the two components needs to be replaced We recommend only using original 4SeasonsSpa parts e Do not use the spa if the first filter has been damaged or is missing 1 5 Water Temperature The water in a spa should never exceed 39 C Water temperatures between 37 C and 39 C are consid
27. ovide you with special cleaning products for your filter cartridge Never use regular soap as it will have a negative impact on the water quality in your spa 4 5 Keeping the Spa Clean The housing is made of red cedar wood treated with oil The housing is maintained by treating it every year with an oil based product ask your spa dealer for the special 4SeasonsSpa oil the ensure you have the same colour Always cover the spa with the supplied cover when it is not in use Mount the supplied clips using small self tapping screws and secure the cover in place Your spa dealer can supply you with the appropriate products to maintain the cover The spa is made of die cast acrylic is weather resistant and does not require any special maintenance It is however imperative that the spa is always covered appropriately Remove dirt using a wet cloth or a soft brush Never use cleaning and or abrasive products It is best for the spa to keep it filled with water and maintain regular filtration cycles An empty spa increases the chances of leaking as the connectors could dehydrate 4SeasonsSpa 17 User manual EasyTop Laing heater 4SeasonsSpa WATER TREATMENT 1 Specific rules for water treatment in your residential spa cannot be prescribed The minimum required standards for spa maintenance are outlined below 4SeasonsSpa is not responsible for providing information about water treatment This page will only provide you with some guidelines Each region or
28. rated By pressing and holding the ECONOMY button for 5 seconds the partial LOCKP display locking is activated By pressing and holding this same button for 10 seconds all functionality is disabled LOCKF By pressing and holding the ECONOMY button again for 5 seconds the display is reactivated 3 5 Boost function This function is used to activate an accelerated filtering procedure of limited duration Pump 1 is started at high speed and the ozone generator runs for 45 minutes To activate the function press and hold the Pump 1 button for 5 seconds This function has to be activated after heavy use of the SPA and or addition of chemical products The display shows the code BOO 3 6 Inverting the display This function is used to invert the direction of the display so as to make it easy to read from the outside Due to the type of software installed it is possible to activate the function as following Press and hold for 5 seconds the Filter Purge The function is disabled in the same way The function is also disabled by switching the pack off 3 7 Temperature unit This function is used to the display the temperature in degrees centigrade or Fahrenheit It is possible to activate the function as following Press and hold for 5 seconds the Light 3 8 Smart Winter Mode The smart winter mode is a setting that is always activated It protects your system from freezing pipes The spa takes measurements of the temperature in the technical r
29. rculation pump on a 24 24 cycle because of the low water flow of this pump PURGE FUNCTION recommended When DIP SWITCH 7 is ON low position and in your LowLevel program CPx is set at always ON and FCx is on Purge cycle your circulation pump will run 24 hours a day see page 23 and 24 Your spa is equipped with 2 jet pumps and a circulation pump Most people install their circulation pump to work 24 hours a day In this case you are able to set a PURGE cycle The circulation pump is working 24 hour a day and you can set 1 2 3 4 6 8 12 or 24 times a day a 1 minute purge cycle During a purge cycle the 2 jet pumps will run on high speed For example when you press the purge button on the display the message is P When you program 24 the spa will have hourly a 1 minute purge cycle If the purge function has been selected in the Low Level Programming the Filter Purge button and the Up and Down buttons can be used to set a certain number of automatic purge cycles per day parameter Pxx minimum value 1 maximum 12 default value 2 When you set the Pxx for example at 12 your spa will run a PURGE cycle each 2 hours for 1 minute Filter function not recommended The Filter Purge button and the Up and Down buttons can be used to set the filtering cycle settings in your LowLevel program First check if DIP SWITCH 7 is in down ON position see page 23 and 24 and check LowLevel program if FC is on Filter Cycle 1 and CP is
30. red value is reached The arrow next to the heater icon will activate giving a solid icon when the heating system is active When LC Low Current is set and if both pumps are activated the system cannot heat the water as this would require too much current the heating icon will start blinking in this case As soon as one of the pumps is switched to low speed or turned off the heating system will automatically activate and the icon will be solid ECONOMY MODE of heating As soon as the economy mode is activated the spa will allow the temperature to drop up to 11 degrees below the set temperature Only use this mode if your spa will not be used for extended periods of time Keeping the spa at the desired temperature is more economical than constantly reheating the water By pushing the Economy button for a few seconds you can program E duration ED delay of start time of the ECONOMY MODE The E duration condition varies from 0 to 24 hours selected with the arrow key s 0 function deactivated and 24 function always active The ED delay until start can be select with a value from 0 till 23 hours see calculation filter time 3 2 3 4 Display Lock It is possible to lock the display partially or entirely which can be a useful safety measure for children There are two options available Full LOCK F none of the buttons will function Partial LOCK P switches operating pump 1 pump 2 and the light can be ope
31. the pack OFF then wait for the water to cool HL flashing p p down tub has reached 44 C 112 F f th bl f h blackout Only Smart Winter Mode is active SANE i sih ee i er i troupiesnooting manual or contact the technical service DO NOT ENTER THE SPA e Check that the low level settings of the circulation The pressure switch flow switch pump and the pressure switch correspond to the configuration of the spa FLO aia hia a ee e Check that the level of the water is sufficient and on pump 1 if the circulation pump that the valves are open is not installed e Clean the filter e If the problem persists refer to the troubleshooting manual or contact the technical service e Check that the circulation pump or pump 1 if the F circulation pump is not installed stops when the a air ah Ai oh error occurs Otherwise check the connections of the loads FLG aro E E aa pat ani ca e Check that the low level settings of the circulation j ae Installed pump pump correspond to the configuration of the spa e If the problem persists refer to the troubleshooting manual or contact the technical service Prr Malfunction in the temperature e Refer to the troubleshooting manual or contact the probe technical service 4SeasonsSpa 24 User manual EasyTop Laing heater 4SeasonsSpa Pumps contain air e The water level is to low causing the skimmer to take in air The diverters are too difficult to turn e Ask your spa deal
32. the pumps Ask you dealer how much to use this depends on the brand anti freeze you use 2 Empty the spa as described in section 5 Emptying the spa The spa plumbing and pumps should not contain any water This cannot be achieved just by regularly emptying the spa 3 Loosen all connections in the mechanical room and release them All connections have to be greased with acid free Vaseline and stored in an area that will not experience frost 4 Secure the cover on the spa and pack the spa as best as possible 5 Before re using the spa make sure it is sufficiently flushed with clean water to remove any remaining old water and anti freeze fluid Note 4SeasonsSpa recommends never leaving the spa without water and no warranty is given to damages resulting from this The various connectors and components could dehydrate resulting in the development of leakages 4 Seasons Spa cannot guarantee the spa will not freeze even if anti freeze is used Freezing of the plumbing can cause cracks which is also not covered by the warranty 4SeasonsSpa 20 User manual EasyTop Laing heater 4SeasonsSpa 6 DIP SWITCHES and LOW LEVEL configuration Inside the EasyTop there is one dip switch with 8 switches that allows modification the settings see chapter 2 3 Low and High current Herewith an explanation of the other 7 dip switches To access the dip switch first disconnect power from the EAsyTop and then open the front cover of the pack T
33. ur spa will drain except for a small quantity left in the foot well This can be removed with a sponge and bucket e Once empty clean with a damp cloth and do not use cleaning products e To finish push garden hose forward and turn outer ring clockwise remove garden hose and attach safety cap Method 2 e Turn power OFF at the breaker e Purchase a small submersible pump from a DIY store and attach it to a hose pipe and place the pump in the foot well of the spa e Place the other end of the hose in a drain and switch on the pump The pump should then drain all of the water out of your spa 4SeasonsSpa 19 User manual EasyTop Laing heater 4SeasonsSpa 5 1 Winter modes The spa can be used throughout the year and especially in winter spa use is very enjoyable In the event of freezing there are special procedures to observe in order to prevent freezing of the plumbing if the spa is not in use We recommend the following if you are not using the spa Winter Measures Method 1 PREFERRED e We recommend to ALWAYS run the spa and to maintain the water correctly This way the spa will use a minimal amount of power Keep the spa filled with water Set the temperature to 16 C Set the filter cycle to 2 hours e Cover the spa The spa cannot freeze as long as the power supply is maintained Winter Measure Method 2 1 Add a significant amount of anti freeze fluid to the water and ensure it is properly distributed by running
34. urrent Configuration To have this configuration you have to put the first dip switch in position OFF up Heater is working at 2 1 kW Phase Phase2 Neutral NINI Heater Ground Heater Neutral Heater Phase Power Supply 1 x 32A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF up Heater is working at 3 3 kW M9 M6 Ph 1 ase L1 L2 Ms 13 Neutral Ground VPLLLLLLLLSLL LL gt 77 Q J4 L2 Heater Ground Heater Phase Heater Phase Heater Neutral 4 spa 10 User manual EasyTop Laing heater 4SeasonsSpa Power Supply 2 x 16A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF up Heater is working at 3 3 kW M9 M6 Phase LI E pean Phase2 LE Mil 13 Neutral MS Ground III III III ZA MB Heater Ground Heater Netural Heater Phase Heater Phase Power Supply 3 x 16A HC High Current Configuration To have this configuration you have to put the first dip switch in position OFF up Heater is working at 5 2 kW M9 M6 Phase1 O m m Phase2 Phase3 L2 AR JM Wi OMS Ground USMIMITIIMAA A cz MIS S 74 Ww Heater Ground Heater Phase Heater Neutral Heater Phase 4 spa 1 User manual EasyTop Laing heater 4SeasonsSpa 3 Spa operation Display Fig 3 1 Icons meaning and light I
35. wing process e Activates the circulation pump if it is not yet running most of the time it is running 24 hours a day e The control system checks that the circulation capacity of the water running through the heater is sufficiently large This operates the pressure switch located on the heating element e The control system activates the heater if enough power is available LC and HC The display will show a blinking arrow on the heating icon when heat is needed but not available This indicates that the heater will be activated as soon as one of the pumps starts running at decreased speed At that point the heater icon will glow continuously on the display indicating that the heater is now active Setting the water temperature above 40 C This function is used to set the desired water temperature in the pool between 40 C and 42 C Hold the Up button for 5 seconds the display shows Or followed by the increase in temperature above 40 C e g to set 41 5 C the display must show Or 1 5 The temperature is decreased using the Down button 4SeasonsSpa 13 User manual EasyTop Laing heater 4SeasonsSpa 3 2 Filter and Purge In the Low Level program it is possible to activate a standard Filter Program or you can program the circulation pump to run 24 hours a day most common setting When a Filter program is activated the circulation pump will run 2 times a day for some hours to take care of filtration We prefer to install the ci
Download Pdf Manuals
Related Search
Related Contents
How to remove Jammed Paper MC851(+)/MC860/MC861(+ 1 What is the UPS-Management Software? 取扱説明書 - Honda カタログ Copyright © All rights reserved.
Failed to retrieve file