1. Press button for 2 seconds and release when the LCD stops blinking Repeat New password to confirm it Press button for 2 seconds and release when the LCD stops blinking It is completion with returing initial mode Note 1234 as a password can t be used to open the door because it s default password You can t open the door with password until you do change default password 1234 into new password 8 H commax TO Opening the entrance of Multi entry panel with password 1 Open the entrance with resident password The doors do not open by default password 1234 you use this function only after changing default password into new one Enter the resident number in Multi Entry Panel Press 0 button Enter the residential PIN number Press lt button The door is opened with the OPEN message displaying on the LCD screen 2 Open the entrance with Building password Enter 9900 in Multi Entry panel Press O button Enter the Building password Press o button The door is opened with the OPEN message displaying on the LCD screen 11 Wiring and System diagram 1 Wiring Diagram Distributor MASTER SLAVE SLAVE 2 9 commax E 2 Wiring method Please pay attention to the polarity of the wires Units will not work properly when mis wired When using UTP CAT 5 cable each cable color should be match
2. an extra power is required for Slave units Communication Method Display 12 7cm 5 TFT LCD Power Stand by 7O0mA Hands free Consumption Maximum operation 500mA Distance Between Floor Distributor UTP 2 0 5 range and households 11 commax t Memo 12 Wa commax
3. be set as a master unit In case more than 2 units are installed in a household one of them should be set as a master and the rest should be set as slave units B The Door Release and Extension call button on the unit run as a selection of a mater or slave unit in this setting mode 6 Wa commax VWs 1 Set in house unit as a master unit 1 Set the ID as 0 on the Multi Entry Panels that should be connected to channel 1 of CCU BS 2 After pressing the Talk button of an in house unit press the extension call button and the door release button at the same time 3 You can communicate with the Multi Entry Panel while the resident s number is displayed on a screen of multi entry panel 4 Press the Door release button on an in house unit then the gt M message is displayed on the Multi Entry Panel Register desired household number in Multi Entry unit and then press J button The electric sound will be heard after completion 5 The registration is complete when you cancel the conversation Repeat this process for other residence s registration 6 Set the ID on the multi entry panel as 1 from 0 after completing the registration 2 Set in house unit as a slave unit 1 Set the ID as 0 on the Multi Entry Panels that should be connected to channel 1 of CCU BS 2 After pressing the Talk button of an in house unit press the extension ca
4. may cause a fire an electric shock or an injury due to malfunction of the product 2 H commax Co Ltd a Warnings and caution A N Caution _ An injury or property losses are expected Prohibition S It indicates prohibition It indicates prohibition of disassembly It indicates prohibition of contact T It indicates dos and don ts iS Prohibition Prohibition If the socket holes are larger than normal do not put the plug It may cause an electric shock or a fire Make sure that dust or foreign substances are not gathered on the product Make sure to prevent foreign substances from entering the product It may cause a breakdown pest gt 0 Prohibition Do not put a heavy object on the product It may cause a breakdown Do not disassemble or give an impact to the product Avoid direct rays of the sun or heating devices at a time of installation Be k E i A Ey Pulling the plug Ey Pulling the plug Install the product in a flat and stable place Otherwise it may not function properly Pull the plug if the pr
5. Home Network Luce 168 COMMAX User Manual VIDEO DOOR PHONE CAV 51AM COMMAX Co Ltd ee en ee N Aa A A N T a www commax com COM MAX Co I Ltd s 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 21 33 e Thank you for purchasing COMMAX products Web site www commax com e Please carefully read this User s Guide in particular precautions for safety before using a product and follow Printed In Korea 2010 04 101 instructions to use a product exactly e The company is not responsible for any safety accidents caused by abnormal operation of the product W Table of Contents Table of Contents e tCSteeeeee 1 Warnings and caution 2 Dg CMS mI 2 Parts Names amp Functions 5 3 Receiving a call from Multi Entry Panel OS 4 Calling sub units Intercommunication 5 Calling Guard or Porter st 6 Call Talk duration _____ _ ________ 7 Setting In House unit as a Master and gt gt 6 Sub Units 8 Chime sound from individual door unit s g 9 The Change and initialization of the password g 10 Opening the entrance of Multi entry panel with g password 1 COMMA a Warnings and caution Make sure to follow the instructions to prevent any danger or property losses S It indicates prohibition It indicates prohibition of disassemb
6. Talk button to end the conversation 5 commax a WA Calling sub units intercommunication 1 Press the Talk and Extension call button in turn to make a call to the sub unit All call to both Master and Slave unit 2 When the sub unit responds conversation occurs When trying to call the Guard station or other sub units during intercommunication nothing happens 3 During extension call if a call made from Multi Entry panel you have the image of visitor with lower call sound talk duration is 30 seconds 4 Start conversion with Multi Entry panel after ending extension call Only one exten sion can have a conversation with Multi Entry panel at a time p Calling Guardlor Porter 1 Press the Talk and Guard call button in turn to make a call to the Guard Station 2 When the guard station responds conversation occurs The Guard station unit does not have an outgoing calling function it can only receive call If the Guard unit is on the line with another residence or Multi entry unit you will hear a busy tone We Call Talk duration This is applied to all calls and conversation 1 Calling time lasts for 30 seconds 2 Talking duration lasts for 60 seconds a 7 Setting In House unit as a Master and Sub Units This setting should be set by the Multi Entry Panel which should be connected to channel 1 of CCU BS A When a single unit is installed in a household it should
7. ed as shown in the wiring diagram The Power of the Master unit is supplied from the Floor Distributor a power source is needed per 8 Floor Distributors without an additional power supply but additional sub units require a separatea power source Power source DC24V 1A cover up to 2 additional sub units Power line connection between Master unit and Sub units should be separated 3 System Diagram Household 1 0000 6 SLAVE 2 Talk Power GND DATA VIDEO 1 0 Or ue 6 SLAVE 1 Talk VIDEO DATA GND Household 1 00000 0 16 MASTER Household Household Lep Talk Power GND 4 4 DATA VIDEO 6P 6P 1 FOO OOIE re GUARD Floor Distributor 1 OO0C00000 8 CCU FS 2 Talk DATA VIDEO Power ziz 1 oooo0oo0oo0o0o0ls8s Building Distributor o CH1 CH2 CH3 CH 4 CCU BS 1 O00000 OT 8 3P Talk DATA VIDEO Power 3P 3P 1 8 1 8 1 8 1 8 Lobby 1 ID 1 Lobby 2 ID 2 Lobby 3 ID 3 Lobby 4 ID 4 W712 Specifications Wiring To floor distributor 6 wires talk2 Date1 Power1 Video1 Gnd1 Power Voltage DC24V 28V 5A Power is supplied from Floor Distributor
8. ll button and the door release button at the same time 3 You can communicate with the Multi Entry Panel while the resident s number is displayed on a screen of multi entry panel 4 Press the Extension Call button on an in house unit then the gt S message is displayed on the Multi Entry Panel Register desired household number in Multi Entry unit and then press J button 5 The electric sound will be heard after completion 6 The registration is complete when you cancel the conversation Repeat this process for other residence s registration 7 Set the ID as 1 from 0 on the multi entry panel after completing the registration 7 commax WS Chime sound from individual door unit Chime will be heard when receving a call from an individual door W9 The Change and initialization of the password 1 Initialization for the password Shut off master unit and turn it on again while holding the extension call button and Door release button at the same time for 3 seconds Note Default password 1234 2 Changing Resident Password through Multi Entry panel Enter Residence Number and button for 2 seconds and release when LCD stops blinking Enter Current password and press button for 2 seconds and release when the LCD stops blinking Enter New Password with 4 digits on Multi Entry Panel displaying NEW PW message
9. ly Warning Death or serious injury is expected It indicates prohibition of contact T It indicates dos and don ts sis It indicates that the plug should be pulled out from the socket eeoeeeeoeneeeeeoeneneeneeeee iii O Prohibition Prohibition Prohibition Do not put the plug in the socket Do not connect to other products Do not forcibly bend the cord or simultaneously while in use put a heavy object on the prod It may generate abnormal heat It may cause breakdown uct or cause a fire It may cause a fire NN GO Ss di Gs cA w A x iy g m VAa N Do not use water thinner or a deter Do not install the product in a Do not forcibly pull out the gent used to wash oil products when humid place cord from the socket you wash the exterior It may cause an electric shock or If the cord is damaged it may Make sure to wash it by usingadryclothto a fire cause a fire or an electric shock prevent any breakdown or electric shock 3 Do not contact Do not disassemble Do not put the plug in the sock Do not disassemble repair or Do not use AC circuit breaker et with a wet hand modify the product It may cause an electric shock It may cause an electric shock It
10. oduct is not used for a long time If the product generates strange sound make sure to pull the plug immediately and contact Commax service center COMMAX Co Ltd E S It indicates that the plug should be pulled out from the socket 3 1 Features CAV 51AM is a hands free type Color Video phone This model can add up to a maximum of 2 sub units and total 3 units is available in each residence And this is a surface mount type video phone that connects to a lobby phone common entry unit through a Floor Distributor CCU FS and Building Distributor CCU BS Each Floor Distributor covers 4 households and one Building Distributor covers 200 households 50EA of CCU FS in each building This model is a hands free type You can talk with a visitor by pushing a Talk button and pushing the Talk button again to end the conversation Communication will be ended automatically when a visitor cancels the conversation 1 DC type Color video phone based on Floor Distributor Hands free type 2 When installing only 1 master unit per household power source up to 32 units is supplied from a Floor Distributor CCU FS without an additional power supply 3 Sub monitors need extra power source 4 5 TFT LCD Monitor 5 This model has 4 buttons Porter Guard station call Door release Talk and Extension call 6 COMMAX chime Sol Mi Do is the ring tone that sounds from Multi Entry Panel Ding D
11. ong sounds from an individual door when there is a call 7 Door release function for Entry panel 8 6 wires including a power line one UTP Cable CAT 5 can be used 4 E commax 2 Parts Names amp Functions COMMAX oO O 10 oe 6 Ci F eto o a 0 3 O 9 oD Details Details Speaker Talk button 2 Power switch 9 Door release button anda Power Lamp 3 LCD 10 Volume control dial C MIC Call sound volume control dial Extension call button Video brightness control dial Porter call button Contrast Control dial Extra buttion Hue Control dial a 3 Receiving a call from Multi Entry Panel 1 When receiving a call from the Multi Entry Panel you will hear the COMMAX chime and the visitor s image will be shown on the screen 2 Pushing a Talk button to make a conversation 3 Pressing Door release button to open the common entrance during a conversation The door get opened with electric sound and the communication is completed The conversation is ended right after the release of the door 4 When conversation is over without door release push a