        Fuji Easy Logic Controller ELC
         Contents
1.  and specifications are subject to change without prior notice for the purpose of product improvement      For safe operation  before using the product read the instruction manual or user manual that comes withthe  product carefully or consult the Fuji sales representative from which you purchased the product     Some of the products listed in this catalog may have limits on their use or location or may require periodic  inspections  Call Fuji s sales representative for further information    For safe operation  wiring should be conducted only by qualified engineers who have sufficient technical  knowledge about electrical work or wiring        Fuji Electric Corp  of America    Park 80 West Plaza II  Saddle Brook  NJ 07663  U S A     Fuji Electric Co   Ltd     ED  amp  CI  Drive Systems Company  Gate City Ohsaki  East Tower    Phone     201  712 0555 11 2  Osaki 1 chome  Shinagawa ku  Tokyo  141 0032  Japan  Fax   201  368 8258   Phone    81 3 5435 7135 8  URL  hitp   www fujielectric com Fax  481 3 5435 7456 9   URL  http   www  fujielectric co jp edc     Materials covered in this document are subject to revision due to the modification of the product     Printed in Japan 2000 12  LOOa HO0  M50 FIS       
2. C 0 to 265V AC  Rated current 3mA 24V 0 5mA 110V   1mA 110V  1mA 230V   2mA 230V  2 Operating voltage  ON 15 to 28 8V ON 79 to 265V ea  a  S OFF 0 to 5V OFF 0 to 40V  Delay time OFF gt ON 3ms OFF gt ON 50ms       ON OFF 5ms ON OFF 50ms j  Analog voltage  O to 10V DC    Resolution 8bits     No  of output points   4points   8points 4points 8points     Load current 10A 250V AC or 8A 30V DC   Analog input  only for NQ2P10R 14C  NQ2P20R 14C      NQ2P20R 14C  52 5  E Products  ltem Ordering code Specifiction   Product code   TimeRy Power NQ2P10R 14 24V DC power supply  input 6points  output 4points Ry10A  no clock function  NQ2P10R 14C 24V DC power supply  input 6points  output 4points Ry10A  clock function  analog 2channel  NQ2P10R 52 100 to 240V AC power supply  input 6points  output 4points Ry10A  no clock function  NQ2P10R 52C 100 to 240V AC power supply  input 6points  output 4points Ry10A  clock function  NQ2P20R 14 24V DC power supply  input 12points  output 8points Ry10A  no clock function  NQ2P20R 14C 24V DC power supply  input 10points  output 8points Ry10A  clock function  analog 2channel  NQ2P20R 52 100 to 240V AC power supply  input 12points  output 8points Ry10A  no clock function  NQ2P20R 52C 100 to 240V AC power supply  input 12points  output 8points Ry10A  clock function  Loader software NQ4H SE Personal computer loader software  with connection cable   Memory pack NQ8P MP For program saving and transferring             A  Safety Considerations           Appearance
3. FUJI       EEIE    Ms CE    Fuji Easy Logic Controller       The ELC incorporates a weekly time setting function that allows you to configure  several control logic sequences based on time  Ideal for replacing control relays  timers  and counters  The ELC is programmed in Relay Ladder Logic using a Windows  programming software or directly on the front panel  These are just a few of the many  ELC applications      E EEEE EEEKESEKEE EZEREK EKEHEFKEEFEEHHEEEFSEEHEEEKEEKEEEHEEKEEEEEEREESEEREEEE E     Opening closing control of doors  gates and shutters      Pump control for supplying and draining water    Garbage waste disposer control   Illumination control of streetlights  show windows and   signboards   Temperature control in greenhouses and plant watering control   Boiler control    Parking area monitoring   Air ventilation system control   Escalator control    Mixing and stirring control for various solvents    Transfer conveyor and sorter control  etc     LAH110a    4 8 power relays  15 timers  8 counters and 8 program timers are packed into a single ELC     SAVE SPACE  REDUCE COST  REDUCE WIRING  LOWER ENERGY CONSUMPTION                Drastically reduce the size of your control panel    The ELC has an extremely compact size  The 10 point type is only 72 x 90 x 57mm and  the 20 point type is only 126 x 90 x 57mm in size  This compact size contributes to the  drastic reduction of control panel dimensions      For example  if a control circuit  including 3 timers and 4 powe
4. ndard  DC 24 V  with RTC   The ELC comes equipped with 2 channel analog inputs  standard  Simple control of analog applications  such as  temperature  speed  and voltage can be achieved without  any optional analog device     Password feature is provided for security  The ELC contains a password feature for preventing  unexpected modification of software with switch operation          Analog input terminals  Model with 24V DC RTC comes    standard with analog inputs         DEL                 Operation switches  Operation switches are used for   writing logic and setting timers and  counters           Interface port   An interface port is provided for  connection to a loader or to attach  a memory pack     Special mounting hardware is not required  The ELC can be mounted with screws on sliding type  mounting holes as well as DIN rails without using any  special mounting clamps     Maintenance free EEPROM is used   Since software information is stored into an EEPROM that  does not require battery backup  the ELC is maintenance  free     Complies with CE marking and UL cUL standards    The ELC is widely applicable throughout the world  with  various global standards such as CE marking and UL     Software data saving with loader and simulation via personal  computer can be done   Software data can be saved by using the loader software  program  The data will help the user to standardize wiring  diagrams  Also  the configured logic can be simulated in a  personal computer   and 
5. or 100 to SE       E al  Power               Monitoring screen  Screen displays logic diagram and  monitoring operating conditions     FUF   EUSCIRIE 10R 14C       Digital output terminals   Output 4 x Relay   10A        Power relays with large capacity of  10A are provided onboard        Monitoring screen displays all operating conditions  The monitoring screen on the front of the ELC indicates to the  user the total status of the ELC at a glance    This screen displays the status of I Os  internal relays  timers   counters  the analog current values and the clock time  as well  as a monitoring screen of the control logic operation     Control logic is easily configured in ladder diagram format with software  Control logic wiring in the ELC is implemented with  software in a ladder diagram format that is developed from  a traditional relay schematic diagram  The user only needs  to program the ELC in Relay Ladder Logic     Large power output relays with switching capacity of 10A are provided  The ELC includes large power output relays with a per  point switching capacity of 10A at 250V AC  or 8A at 30V  DC  These output relays can be directly connected to  illumination lamps and valves for control     Schedule management is achieved by using clock function  The ELC   s equipped with RTC allow the user to program a  daily or weekly control schedule without expensive time  management system  Also  the ELC incorporates day light  savings time     2 channel analog inputs are sta
6. r                               relays are replaced with the ELC o O gt  maa   10 points type   the mounting space mos    mi  may be reduced by about 50   ue Soe          Reduce hardware cost     The ELC has an attractive price to help your bottom line   Please contact Fuji Electric for more detail       For example    if a control circuit including 3 timers and 4 power relays  are replaced with the ELC  10 points type   the cost will  be reduced by about 20         Reduce wiring time    When individual Relays  Timers and Counter are used the  wiring of each component becomes tedious  The ELC can  drastically reduce the wiring the because only 1 component is  involved  Further more  if changes to the logic need to be  made these can be done in software or via the front panel        Energy saving operation   The ELC can be programmed  to save electricity  A time  management function can be  programmed to shutdown  Fans  Lights  etc  to save  energy        Improve  Productivity        The ELC comes standard with  Relay Ladder logic schemes  for control applications    The ELC can easily copy  logic schemes by using the  optional memory pack    The control logic connections  take considerably less time to  implement than traditional  hard wiring                    SAVE TIME     The ELC will help improve productivity     Digital input terminals    Power supply terminals    tw 3 4 15 6 AA  EALLI LI    200V AC and 24V DC  DC24V Input 8x DC   A1 A2 0 10V     Power supply terminals f
7. therefore  performance of the  logic scheme in the  ELC can be verified  prior to installation         O  B EOT EERE       aie          E Specifications   General specifications                                                                                                                                                                            NQ2P10R 140   NQ2P20R 1401   NQ2P10R 520   NQ2P20R 520  NQ2P O R U   NQ2PUR UC  Power supply voltage   20 4 to 28 8V DC 85 to 264V AC Programming language   Ladder  function brock  Power consumption   2W  3W 3VA    7VA Program memory capacity   240steps  4elements x 60lines    Output current Max  10A Backup Built in EEPROM  memory pack option  Electrostatic discharge   EC801 2 Severity3 Input relay 12points  11 to C   Contact discharge  4kV  aerial discharge  8kV Output relay 8points  Q1 to Q8   Radioelectromagnetic field  IEC801 3 10V m Auxiliary relay 15points  M1 to MF   Operating ambient IEC801 4 Severity3 2kV RTC relay 8points  R1 to R8   temperature 0to 55  C Counter 15points  C1 to C8   Relative humidity 20 to 90 RH no condensation Timer 4points  T1 to TF   Vibration IEC68 2 6 9 8m s  Analog comparison Apoints  G1 to G4   Shock IEC68 2 27 147m s  Analog input x 2channel  A1 to A2  only for DC  Construction IP20 RTC x      1 O specifications E Dimensions  mm   NQ2P10R 140   NQ2P20R 140   NQ2P10R 5201  NQ2P20R 520 2 9 4 5  No  of input points   6points 12points  0points  6points 12points om esis a      Rated voltage 0 to 28 8V D
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung Blu-ray grotuvas H5500 Vartotojo vadovas  Ashly FET-1000M User's Manual  Samsung GN642HFGD Manual de utilizare  Samsung PN64F8500AFXZA User's Manual  HPTN-MTN Lab Manual - HIV Prevention Trials Network  User Manual - flixsyndication.net  ISOGEN II (PDF 220KB)  Samsung GT-E1120 Benutzerhandbuch  LRG 16-9 - Gestra AG    Copyright © All rights reserved. 