Home
PELLET STOVES USER MANUAL
Contents
1. INSERTO COMFORT PLUS CRYSTAL For the model it is mandatory to duct the hot air There is a cover on the back which must necessarily be removed and connected to the ducting ENGLISH 7 OExtraflame PEDESTAL ASSEMBLY OPTIONAL Position the base in the desired point and use the feet to adjust the desired height the bolts are positioned in the four external sides of the pedestal in the lower part Remember the power socket on the rear of the pedestal so that the plug is accessible once installation is completed Fix the pedestal to the floor using strong steel plugs with a diameter of 8 mm Fix the sliding base to the frame using bolts Connect the flue gas exhaust pipe and the air vent as stated in the previous paragraph Take the insert tilt it so that the wheels fit into the relative rails make it run until the flue gas auger is completely inserted into the flue gas conveyor box Finally open the fire door and use the su
2. 7A Fares motor disassembly and deaning and fumes new silicone in required points inspection of gaskets ah drawer and burn pot door replace them and apply slicone where required _ EB Room air fan disassembly and removal of dust and any pellet debris Air intake pipe inspection and any flow sensor cleaning ENGLISH 27 OExtraflame DISPLAYS DISPLAY Stove off START The start phase is in progress PELLET FEEDING Pellet feeding during the ignition phase is in progress IGNITION The ignition phase is in progress START UP The start phase is in progress The normal work phase is in progress MODULATION BURN POT CLEANING The automatic burn pot cleaning is in progress FINAL CLEANING When the stove is switched off final cleaning is in progress The final cleaning phase lasts about 10 minutes STAND BY Stove off due to temperature reached and in stand by for re ignition EXT STAND BY Stove off due to an external thermostat in stand by for re ignition A new ignition is attempted when the stove has just been switched off When the stove switches off one COOLING STAND BY must wait for the complete shutdown of the fumes motor then clean the burn pot The stove can only be re ignited when these
3. INSERT EXTRACTION The extraction of the insert allows pellets to be loaded inside the um 22 13 5 A N NA 7 eu e ze 2 feed box and to perform routine maintenance cleaning the ash SSSSs 1 pipe at the end of the year or special maintenance replacement of T mechanical parts if the product should break 4111 iS Follow this procedure to extract the insert Open the fire door and by means of the supplied poker turn the lockbolt located at the bottom left corner anticlockwise Using the relevant pokers pull the machine towards yourself until it blocks automatically 10 ENGLISH OExtraflame MOUNTING THE FRAMES Front frame Side frames PELLETS AND FEEDING The pellet used must comply with the features described by Standards EN PLUS UNI EN 14961 2 UNI EN ISO 17225 2 class A1 A2 For its products the manufacturer always recommends using pellets with a diameter of 6 mm To guarantee combustion without problems the pellets must be kept in a dry place We recommend using pellets with a diameter of 6 mm with our products See the images for feeding pellets N B A
4. 23 CLEANING AND MAINTENANCE BY THE 23 ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS 27 POTTING THE EQUIPMENT OUT OF SERVICE END OFTHE SEASON eerie Ie 27 DDISPEAY A Mn 28 iu cM M n 28 GUARANTEE tico 30 ENGLISH 3 OExtraflame We thank you for having chosen our company our product is a great heating solution developed from the most advanced technology with top quality machining and modern design aimed at making you enjoy the fantastic sensation that the heat of a flame gives in complete safety WARNINGS This instructions manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost request another copy from the area technician This product is intended for the use for which it has been expressly designed The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to pe
5. 8 US 18 Pm 10 rA re NET c 11 5 co 11 FRONT TILTING DEFLECTOR emm 12 TB a x 68016 oa trent non 12 CEO IN 12 CONTROL PANEL 13 Bim B S 13 GENERAL 14 E 14 oe 15 PELA CTO WEACH OFF ENABLING mrt P 15 PON REPLACEMENT OF BATTERIES cc 15 COMMISSIONING SETTINGS vicsscsssscssastscacsecssisticscsscnsasaienssnetentensseesensd npencneensssesstesstecadudsbossasssseabensiaqoseasesseeaboasasesestessccabaneseotins 15 MAINS FRE EO UENCE E E 16 ADJUSTING TIME DAY MONTRH AND YEAR 16 0501 mc EE
6. 16 OPERATION AND LOGIC eism E 17 ADDITIONAL THERMOSTAT OPTIONAL Ek TH UR EVE OR VE Re 18 4j 5 M oisit 18 BRI y er 18 gO oa 2 10105 0 18 P 19 Bg mrt 19 eyEee ipm M 20 DR p 21 n 21 ENABLE CHRONO e 21 CHIRON 10 m 21 EX ANE ic C c M 22 CLEANING AND MAINTENANCE UE Ya RU V VR EN UNS RES AN OVES ER CEPR S 23 M
7. Make sure the holes at the burn pot bottom are completely free Check cleanliness of the fumes pipe and the combustion chamber Check hermetic door closure Check hermetic closure of the ash drawer Other restoration operations must be carried out by an authorised technician Contact after sales centre Check for the presence of pellets in the feed box Adjust pellet flow see Pellet feed adjustment Check the procedures described in the Ignition chapter Other restoration operations must be carried out by an authorised technician Set the stove on OFF using key 1 and repeat the procedure described in the Ignition chapter Other restoration operations must be carried out by an authorised technician Check for the presence of pellets in the feed box Regulate the pellet flow Other restoration operations must be carried out by an authorised technician Every time the stove displays one of the alarms listed above it will switch off automatically The stove will block any alarm unlock attempt during this phase showing the alarm itself and STAND BY alternately on the display The alarm can be reset by pressing button 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed Contact after sales assistance Contact after sales assistance Contact after sales assistance ENGLISH 29 Extraflame GUARANTEE TERMS 1 Extraflame S p A product
8. DO NOT PULL DISCONNECT TWIST ELECTRIC CABLES LEAVING THE STOVE EVEN IF DISCONNECTED FROM THE ELECTRIC POWER SUPPLY MAINS ITIS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO CONTACT WITH HOT PARTS OF THE APPLIANCE THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTER INSTALLATION DO NOT CLOSE OR REDUCE THE DIMENSIONS OF THE AIRING VENTS IN THE PLACE OF INSTALLATION THE AIRING VENTS ARE ESSENTIAL FOR CORRECT COMBUSTION DO NOT LEAVE THE PACKAGING ELEMENTS WITHIN REACH OF CHILDREN OR UNASSISTED DISABLED PERSONS THE HEARTH DOOR MUST ALWAYS BE CLOSED DURING NORMAL FUNCTIONING OF THE PRODUCT WHEN THE APPLIANCE IS FUNCTIONING AND HOT TO THE TOUCH ESPECIALLY ALL EXTERNAL SURFACES ATTENTION MUST BE PAID CHECK FOR THE PRESENCE OF ANY OBSTRUCTIONS BEFORE SWITCHING THE APPLIANCE ON FOLLOWING A PROLONGED PERIOD OF INACTIVITY THE GENERATOR HAS BEEN DESIGNED TO FUNCTION IN ANY CLIMATIC CONDITION IN PARTICULARLY ADVERSE CONDITIONS STRONG WIND FREEZING SAFETY SYSTEMS MAY INTERVENE THAT SWITCH THE GENERATOR OFF IF THIS OCCURS CONTACT THE TECHNICAL AFTER SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS IN THE EVENT THE FLUE CATCHES FIRE USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE THIS APPLIANCE MUST NOT BE USED TO BURN WASTE DO NOT USE ANY FLAMMABLE LIQUIDS FOR IGNITION DURING THE FILLING PHASE DO NOT PUT THE BAG OF PELLETS TO INTO CONTACT WITH THE PR
9. ADJUST COMBUSTION ACCORDING TO THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED E CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES 5515 u E 1 16 ENGLISH OExtraflame OPERATION AND LOGIC sc WW IGNITION Once the points listed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are given for the ignition stage after ignition and once the control temperature has been reached the stove interrupts the ignition phase and switches to the START UP mode STARTING During the start up stage the stove stabilises combustion increasing it gradually to then start ventilation and switch to the WORK mode WORK During the work stage the stove reaches the set power and works to reach the set room temperature See following item THERMOSTAT SETTING ADJUSTMENT The room temperature setting can be set using buttons 4 and 5 from Low 07 to 40 C Hot LOW HOT If the temperature setting is on Low set below the 7 C threshold the stove will always function at minimum If the setting is on Hot set above the 40 C threshold the stove will not modulate always functioning and only at the set power ADJUSTING POWER SETTING The power setting features 5 operating lev
10. Hot To confirm and proceed press key 6 1ST TIME SLOT SWITCH ON ELE Ba Use keys 4 5 to enter time 08 00 At this point the second time slot must be which corresponds to the switch on time of START PRG1 START PRG2 the 1st time slot 08 00 Ll uu 22777177 The sequence to be followed is the same OFF and is repeated as per the 1ST TIME SLOT press button 6 Press button 3 to go back to as per the 1ST TIME SLOT the previous parameter 2ND TIME SLOT SWITCH ON At this point the second time slot must be programmed The sequence to be followed is the same and is repeated as per the 1ST TIME SLOT SWITCH ON On this occasion simply enter the time for example start at 15 00 and Stop at 22 00 and to activate the days Saturday and Sunday by setting them at ON WHEN THE WEEKLY PROGRAMMER IS ACTIVE A BOX OF THE RELATIVE ICON WILL APPEAR ON THE CONTROL BOARD 22 ENGLISH OExtraflame CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS Make sue the power cable is unplugged since the generator could be programmed to start That the generator is cold in its entirety The ashes are completely cold Ensure an effective exchange of air in the room during the cleaning of the product A poor cleaning is detrimental to the proper functioning and safety 9 99 MAINTENANCE For correct operation the generator must undergo routine maintenance by a quali
11. must be minimal and in any case no longer than 3 metres with a minimum upward slope of 3 There must not be more than 4 direction changes including the one due to the use of the T element fitting with a condensation collection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is inserted in an existing flue it must be certified for solid fuel If the smoke duct is outside the building it must always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be provided for cleaning 9 9 CHIMNEY CAP The chimney caps must meet the following requirements they must have a useful outlet section no less than double that of the chimney ducted system on which it is installed they must be adapted in order to prevent the penetration of rain and snow in the chimney ducted system they must be built so that in the event of winds coming from all directions and from any angle the expulsion of combustion products is in any case ensured EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Protection from rain and wind Protection from rain and
12. the insert to the floor Components description A Primary air intake pipe B Flue exhaust pipe C Adaptation frame D Sliding base and rails E Plug for power socket F Ducting pipe ASSEMBLY WITH SLIDING BASE Take the sliding base and position it in the pre existing flue Use chalk to mark the blocking holes of the base on the flue surface Drill 8 mm holes for the steel expansion inserts Make a hole measuring 60 mm in line with the air intake Remember the power socket on the rear of the insert so that the plug is accessible once installation is completed Fix the base using the clamping screws Create a flue exhaust and socket connection respecting the points described previously Take the insert tilt it so that the wheels fit into the relative rails make it run until the flue gas insert is completely inserted into the flue gas conveyor box
13. the regulations and the manual The tank must be full of pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the fire door and the ash drawer Check that the power supply cable is connected correctly The bipolar switch in the rear right part must be positioned on 1 9 9 BURN POT DIVIDER ITIS FORBIDDEN TO USETHE APPLIANCE WITHOUT THE DIVIDER AND OR GLASS PROTECTION SEE THE FIGURE TO THE SIDE ITS REMOVAL JEOPARDISES THE SAFETY OF THE PRODUCT AND IMMEDIATELY VOIDS THE WARRANTY PERIOD INTHEEVENT OFWEARORDETERIORATION CONTACTTHE ASSISTANCE SERVICE TO REPLACE THE PART THE REPLACEMENT IS NOT COVERED BY THE PRODUCT WARRANTY AS IT IS A PART SUBJECT TO WEAR e GLASS PROTECTION 14 ENGLISH OExtraflame THE REMOTE CONTROL All that can normally be implemented through the LCD can be adjusted using the remote control The table below provides a detailed description of the various functions NON t BAe CO OW 1 ON OFF Pressing the key for three seconds the stove will switch on or off 2 POWER INCREASE Pressing the key will increase the operating power 3 POWER DECREASE Pressing the key will decrease the operating power 4 T INCREASE The temperature setting can be increased by pressing this key 5 T DECREASE The set temperature can be decreased by pressing th
14. wind Insulated flue 9 Q 40 405 02020502 3 mt Insulated T fitting with inspection plug a 3 5 T fitting Condensation proof with T fitting with inspection inspection plug plug 0 d CONNECTION TO THE MAINS ELECTRIC SUPPLY The generator is supplied with an electric power cable to be plugged into a 230V 50 Hz socket possibly with a circuit breaker switch The Socket must be easily accessible The electrical system must be compliant with standards The efficiency of the earthing circuit must be checked Unsuitable earthing of the system can cause malfunctioning for which the manufacturer will not be held liable Power supply variations beyond 1096 can cause faulty operation of the product 6 ENGLISH OExtraflame INSTALLING INSERTO COMFORT PLUS CRYSTAL The insert is supplied with a sliding metal base that allows it to be installed in a pre existing flue The sliding base allows the easy extraction of the insert both for feeding pellets into the feed box and for any maintenance or cleaning at the end of the season If there is no pre existing flue it can be built using the insert support pedestal optional kit in fact the latter attaches
15. 05 00 ENGLISH 21 OExtraflame PROGRAMMING EXAMPLE Let s suppose that the weekly Programmer function is to be used and 4 time slots are to be used in the following way Ist time slot from 08 00 to 12 00 every day of the week with room temperature at 19 C excluding Saturday and Sunday 2nd time slot from 15 00 to 22 00 only on Saturday and Sunday with room temperature at 21 C 1ST TIME SLOT SWITCH OFF CONTROLS PROCEDURE SET CLOCK Use keys 4 5 to enter the time 12 00 which corresponds to the switch off time of STOP PRG1 Press key 2 until enable chrono appears the 1st time slot 12 00 Enable the chrono To confirm and continue programming Enable slot 1 and 2 ENABLE press button 6 Press button 3 to go back to Press key 1 to exit CHRONO the previous parameter Press key 6 and SET CLOCK will appear in the menu enabling is done directly in To enable disable the days use keys 4 and PETC PRONO CHRONO 5 key 2 and 3 to scroll the various days the MONDAY PRG1 CONTROLS PROCEDURE SETTING A week will appear followed by ON OFF select from Monday to Friday on ON excluding Saturday and Sunday OFF Press key 2 and SET CHRONO will appear 1ST TIME SLOT 2 TEMPERATURE SETTING Press key 6 to confirm and continue START PRG1 Press key 6 to confirm and continue programming OFF programming SET PRG1 Using buttons 4 5 select the desired 19 C START PRG1 OFF will appear temperature Low 07 40 C
16. AL MINIMUM SURFACE 550 CM C THIS VENTILATION SYSTEM IS TOTALLY INDEPENDENT FROM THE AIR INTAKE FOR COMBUSTION F 5 cm ELE 2 1 i he gt vi 5 n 1 Minimum 5 cm 5 5 For correct functioning of the insert during construction of the flue z the measurements between the insert and internal walls of the flue must be respected figure below From the clearance measurements of the stove given in the technical features it is necessary to consider at least 50 mm of air in the upper part and on the 2 sides C THE INSERT MUST LIE AT LEAST 1 CM ABOVE THE FIRE SURFACE IN COVERING MARBLE It is just as important to guarantee the minimum distance of 5 cm on
17. CIExtrafiame Riscaldamento a Pellet PELLET STOVES USER MANUAL INSERTO COMFORT PLUS CRYSTAL ENGLISH INGLESE OExtraflame 2 ENGLISH OExtraflame 4 WARNINGS 4 SALPET ewe M 4 ROUTINE MAINTENANCE emm H 4 INSTALLATION 5 CENE 5 INSTALLING INSERTO COMFORT PLUS CRYSTAL 7 ASSE MBEF ILES MIS egi i 7 INSERTO COMFORT 2 CRYSTAL cc c M 7 PEDESTAL ASSEMBLY OPTIONAL cvsistssicesssctassssnssdscectsssdsscstecassisvecscsetesdenssvesccsstnesusenetassctlewsesiesacdsossecssceassesssocasisisssausesccdsisssve 8 FRONT PELLET FEEDING KIT OPTIONAL sessississessssnciscsssssecsscastcsavecssactedscassocisessasassessecessscesesensscaiiesaseasstsencsadesssscsdssseccuestansoaie 8 AIR CIRCULATION l dcm
18. FLECTOR CLOSING Pull the tang which is located to the left outwards to unblock the deflector See figure to the side ATTENTION THE DEFLECTOR MUST ONLY BE CLOSED UPON TOTAL COMPLETION OF THE COOLING PHASE OFF IMPORTANT NOTES If the insert start up button is pressed when the deflector is closed the display will signal GRATE CLOSED CAUTION and will not enable start up of the insert ass e Ifthe deflector is closed during the functioning phase the display will signal GRATE CLOSED CAUTION for 30 seconds together with an intermittent acoustic signal If the deflector is not opened during signalling the insert will automatically go into switch off FINAL CLEANING phase To enable the chrono function you must first open the deflector If the CHRONO function is enabled and the deflector is closed the display will immediately signal GRATE CLOSED CAUTION and will not permit start up at the preset time 12 ENGLISH OExtraflame CONTROL PANEL ON OFF BUTTON OPERATION POWER ADJUSTMENT DISPLAY OF VARIOUS TEXT MESSAGES TEMPERATURE SETTING TO ACCESS THE MENU White On Flashing white Pellet tank reserve Red Off Green STBY Flashing red In alarm DISPLAY ICONS KEY A a Indicates the receipt of the radio signal On during radio communication Off no radio communication Fixed on serial input disabled It indicates weekly programming functio
19. NUTES 00 59 Confirm using key 6 DATE 12 31 Use keys 4 and 5 to select the day MONTH 1 12 Proceed by pressing key 2 With the same procedure use keys 4 or 5 to set and key 2 to M DUE move forward to adjust the hours minutes day month and year Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 9 9 9 ADJUSTING LANGUAGE It is possible to select the preferred language to display the various messages SET LANGUAGE CONTROLS PROCEDURE ITALIAN ENGLISH Press key 6 and SET CLOCK will appear ERMAN Press key 2 until SET LANGUAGE appears PSE AE 5 Confirm using key 6 FRENCH Select the language using key 4 or 5 SPANISH Press key 6 to confirm and key 1 to return to the previous menus up to the initial status NO IGNITION FIRST IGNITION COULD EVEN FAIL AS THE AUGER IS EMPTY AND IS NOT ALWAYS ABLE TO LOAD THE BURN POT WITH THE REQUIRED AMOUNT OF PELLETS ON TIME TO REGULARLY START THE FLAME IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS WORKING CHECK THAT ROUTINE CLEANING STATED IN THE STOVE BOOKLET HAS BEEN CARRIED OUT CORRECTLY CLEAN CHECK UP 1 2 IN THE EVENT THE ALL NO FLUSSO ALL CLEAN CHECK UP ALARM IS TRIGGERED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE OF RESIDUES OR SCALES THE HOLES AT THE BOTTOM MUST BE COMPLETELY FREE TO GUARANTEE CORRECT COMBUSTION ONE CAN USE THE FUNCTION PELLET FEED ADJUSTMENT TO
20. ODUCT THE MAJOLICAS ARE TOP QUALITY ARTISAN PRODUCTS AND AS SUCH CAN HAVE MICRO DOTS CRACKLES AND CHROMATIC IMPERFECTIONS THESE FEATURES HIGHLIGHT THEIR VALUABLE NATURE DUETO THEIR DIFFERENT DILATION COEFFICIENT THEY PRODUCE CRACKLING WHICH DEMONSTRATE THEIR EFFECTIVE AUTHENTICITY TO CLEAN THE MAJOLICAS IT IS RECOMMENDED TO USE A SOFT DRY CLOTH IF A DETERGENT OR LIQUID IS USED THE LATTER COULD PENETRATE INSIDE THE CRACKLES HIGHLIGHTING THEM ROUTINE MAINTENANCE Based on Decree 22 January 2008 n 37 art 2 routine maintenance means interventions aimed at reducing degradation due to normal use as well as dealing with accidental events entailing the need of first interventions which however do not modify the structure of the system upon which one is intervening or its intended use according to the requirements laid down by the technical standards in force and by the manufacturer s use and maintenance manual 4 ENGLISH OExtraflame INSTALLATION GENERAL The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards The installer must provide the owner or person acting for him according to the legislation in force with the declaration of conformity supplied with 1 the use and maintenance manual of the appliance and of the system components such as for example the smoke ducts chimney etc 2 photocopy or phot
21. OLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 Press key 2 until RESET appears Press keys 4 5 to select ON and press key 6 DONE will appear on the display to confirm ENABLE CHRONO It allows to enable disable the chrono and the various time slots CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until ENABLE CHRONO is displayed Press key 6 to confirm and use keys 4 5 to enable ON or disable OFF the chrono Use keys 2 3 to select the desired time slot Use keys 4 5 to enable ON or disable OFF the selected time slot Press key 1 several times to confirm and exit the menu CHRONO The chrono allows to program 4 time spans within a day to use every day of the week The switch on and switch off time can be set in every time slot along with the days of use of the programmed time slot and the desired room temperature 07 40 C RECOMMENDATIONS The ignition and switch off times must be within the arc of one day from 0 to 24 and not over several days Before using the chrono function set the current day and time Therefore check that the points listed in the Set clock sub chapter have been followed so that the chrono function works Aside from programming it activate it as well EXAMPLE SWITCH ON TIME 07 00 IGNITION 22 00 SWITCH SWITCH OFF TIME 18 00 CORRECT
22. STOVE DURING THE FILLING PHASE IN THE EVENT OF CONTINUOUS NO IGNITION CONTACT AN AUTHORISED TECHNICIAN gt DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION ENGLISH 17 OExtraflame ADDITIONAL THERMOSTAT OPTIONAL The appliance can control the room temperature using an additional external thermostat optional After ignition pressing key 1 or via chrono mode the stove will work to reach the setting set on the thermostat displaying WORK contact closed The standard room probe is automatically ignored When the room temperature has been reached open contact the stove will go to minimum displaying MODULATE TO INSTALL AND ENABLE IT Amechanical or digital thermostat is required Remove the plug from the socket Referring to the figure to the side connect the two thermostat wires dry contact not 220 V on the relative terminals at the back of the machine one is red and the other one is black Power the stove Press key 5 setting the temperature on LOW The stove is now configured correctly It will work controlling the additional external thermostat C INSTALLATION MUST BE PERFORMED BY QUALIFIED STAFF AND OR THE MANUFACTURER S TECHNICAL AFTER SALES ASSISTANCE THERE ARE TWO STOVE OPERATING MODES WHICH ARE DIFFERENT ACCORDING TO THE STAND BY FUNCTION SEE STAND BY CHAPTER USER MENU DISPLAY This menu allows to adjust the brightness of the dis
23. aflame In the presence of type B gas appliances with intermittent operation not intended for heating they must have their own aeration and or ventilation opening The air inlets must meet the following requirements they must be protected with grids metal mesh etc but without reducing the net useful section they must be made so as to make the maintenance operations possible positioned so that they cannot be obstructed The clean and non contaminated air flow can also be obtained from a room adjacent to that of installation indirect aeration and ventilation as long as the flow takes place freely through permanent openings communicating with the outside The adjacent room cannot be used as a garage or to store combustible material or for any other activity with a fire hazard bathroom bedroom or common room of the building FLUE GAS EXHAUST The heat generator works in depression and is equipped with an outlet fan for flue gas extraction There must be a single exhaust system for the generator Using a flue that is shared with other devices is not allowed The components of the flue gas exhaust system must be chosen in relation to the type of appliance to be installed in compliance with UNI TS 11278 in the event of metal chimneys with particular attention to that stated in the specification UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 in the event of non metallic chimneys The length of the horizontal section
24. arth wall obstructs the regular flow of fumes thereby affecting the performance and regular operation of the stove Open the door to access the combustion chamber Take out the burn pot Remove or rotate depending on the model the upper lockbolt A the screws B or the wall lock C of the hearth wall D take out the hearth wall E and clean with the poker and a suitable vacuum cleaner F When cleaning has been completed reposition the removable hearth wall D and secure it again with the designated screws by turning the lockbolt in the opposite direction in relation to the one used to remove it or by placing back the hearth wall lock Place back the burn pot ENGLISH 25 OExtraflame TET CLEANING THE LOWER SUMP IF THERE IS ONE Some stove models have an inspection sump behind the ash drawer or underneath the combustion chamber In this case just open remove the clamping screws and vacuum the ash inside ENGLISH OExtraflame ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS Routine maintenance must be performed at least once a year As the generator uses pellets as solid fuel it needs an annual routine maintenance interval that needs to be performed by an authorised Technician by only using original spare parts Failure to do so can affect the appliance s safety and you may no longer be entitled to the warranty conditions By following the cleaning schedule reserved to the user and reported i
25. aulty The flue exhaust pipe is blocked Incorrect installation hanical i DEPR ALARM The mec anical depression sensor has tripped The pellet feed box is empty NO Pellet feed calibration inadequate IGNITION Incorrect installation BLACK OUT NO IGN In the work phase the t of the flue NO PELLETS gases has dropped below default parameters Attempt to release the alarm with stove still in cooling mode CLEAN CHECK UP 1 2 1 IN START UP STAGE 2 IN OPERATING STAGE COOLING STAND BY DEBIMETER FAULT Component disconnected or faulty AUGER CONTROL ALARM Anomalous functioning of pellet feeding Abnormal functioning of pellet motor AUGER BLOCK The combustion chamber or burn pot No current during the ignition phase On indicates the presence of an alarm Off indicates the absence of alarms Flashing indicates the deactivation of the depression sensor The alarm can be reset by pressing button 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed The restoration operations must be carried out by an authorised technician The restoration operations must be carried out by an authorised technician Check pellet flow see Pellet feed adjustment Check that the machine is clean including the fumes passage Do not rest cloths on the machine Other restoration operations must be carried out by an authorised technician
26. both sides as shown in the figures above V Reference A Hot convection air The heat accumulated inside the covering must be vented to prevent excessive overheating of i B the insert Reference B Forced ventilation The tangential fan distributes the heat developed by the insert into the environment Reference C Airinlet from the room To allow air recirculation an air inlet point must be envisioned which is preferably positioned in the lower part of the structure in order to encourage convection The air must be withdrawn from the machine s working environment ee as ee ee ee ee AM 222222 221422 2222222222 C THE FLUE OUTLET PIPE MUST ALWAYS MAINTAIN A MINIMUM DISTANCE OF 50 MM FROM INFLAMMABLE PARTS ENGLISH 9 OExtraflame Fixed Inserto COMFORT PLUS CRYSTAL Air inlet cm 275cm INSERT LOCKING AND RELEASING SAFETY DEVICE Open the fire door and by means of the supplied poker turn the lockbolt located at the bottom left corner clockwise 2 LL FJ X _ A Wir To understand whether the insert is attached to the base properly connect the plug to the socket and make sure it works with the supplied remote control
27. cinerator Do use the product as a ladder or supporting structure Do not place laundry on the product to dry it Any clothes horse or similar objects must be kept at due distance from the product Danger of fire or damage to the coating The user is fully liable for any incorrect use of the product The manufacturer bears no civil or criminal liability for incorrect use Unauthorised tampering of any nature or replacement of spare parts of the product with non original parts may endanger the operator and the manufacturer bears no civil or criminal liability for this Large parts of the surface of the product can get very hot door handle glass smoke outlet pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product with the door open or if the glass is broken The product must be electrically connected to a system equipped with an operational earthing system Turn off the product in the event of a failure or malfunctioning Unburned pellets that build up in the burner following each failed start up must be removed before attempting to start up the product again Make sure that the burner is clean and correctly positioned before starting it up again Do not wash the product with water Water may penetrate into the unit and cause faults in the electrical insulation This can cause elect
28. e external additional thermostat is open and the STBY function is disabled Flashing with open contact OExtraflame GENERAL MENU 22 5 C 14 10 ENABLE CHRONO p 2 GM mme ENABLE CHRONO PROG 1 2 3 4 ON OFF TECHNIC SET RESERVED TO THE QUALIFIED TECHNICIAN ONONO Where present CONFIRM WITH KEY 6 DISPLAY PELLETS D SUNDAY PRG1 MONTH IN ON OFF V1 AIR TANGENTIAL STAND BY 2 KEYS LOCKED V2 AIR DUCTING 12 GO BACK EXIT 2 3 PARAMETER SCROLLING NEXT 2 PREVIOUS 3 4905 MODIFY SETTINGS DATA INCREASE 4 DECREASE 5 6 CONFIRM ACCESS MENU DAY 1 START PRG1 STOP PRG1 MONDAY ON OFF MINUTES DATE D SET PRG1 YEAR REPEAT THE SAME STEPS FOR THE OTHER 3 TIME SLOTS BASIC INSTRUCTIONS The following recommendations must be followed the first times the stove is ignited Faint smells may be produced the drying of the paints and silicones used Do not remain in the environment for long periods Do not touch the surfaces as they could still be unstable Air the room well several times The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste Before lighting the stove the following points must be verified The hydraulic system must be completed in compliance with the guidelines of
29. efault delay time displaying stand by When the room temperature is 2 C lower than the setting and once the stove has cooled it will start to work again at the set power and displaying work STBY FUNCTION SET AT OFF DEFAULT SETTING ENGLISH 19 OExtraflame If the Stby function is not active OFF if the stove reaches the set room temperature it will go to minimum modulating and displaying modulate When the room temperature is below the setting it will start to work again at the set power and displaying work STAND BY WITH ADDITIONAL THERMOSTAT The STBY function is used if immediate stove switch off is required when the set temperature has been reached By default the STBY function is always set on OFF light o on e _ STBY FUNCTION SET AT OFF DEFAULT SETTING If the STBY function is not active OFF if the stove reaches the set room temperature it will go to minimum modulating and displaying MODULATE When the room temperature is below the setting it will start to work again at the set power and displaying WORK e FUNCTION SET AT ON When the STBY function is activated ON the stove upon reaching the set room temperature and exceeding it by 2 C will switch off after a pre set default delay displaying STAND BY When the room temperature is 2 C lower than the setting the stove will start to work again at the set power displaying WORK CONTROLS PROCEDURE Press key 6 and SET CLOCK WILL APPEAR P
30. els via button 5 access 1 and 2 adjustment Power 1 minimum level Power 5 maximum level WORK WITH ROOM PROBE STANDARD The appliance controls the room temperature via a probe fitted on the appliance Once the the set temperature has been reached it will automatically go to minimum or switch off activating the Stand by function reducing pellet consumption to a minimum By default the STBY function is always set on OFF light o O For its activation and logic follow the indications on the next page chapter Stand by BURN POT CLEANING During the work stage the stove has an internal counter which cleans the burn pot after a set amount of time This stage will be shown on the display it will bring the stove to a lower power level and will increase the fumes motor for a programmed amount of time When the cleaning stage is finished the stove will continue its work going back to the selected power level SWITCH OFF Press key 1 for three seconds When the operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The fumes motor and the hot air ventilation motor will remain on until the temperature of the stove has dropped below the factory parameters RE IGNITION The stove can only be re ignited if the flue gas temperature has lowered and the preset timer has been reset to zero DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT
31. fied technician at least once a year The routine checks and maintenance operations must always be performed by qualified trained technicians in accordance with the applicable regulations in force and with the instructions provided in this use and maintenance manual EVERY YEAR MAKE THE EXHAUST FUMES SMOKE DUCTS AND T FITTINGS INCLUDING CAPS AND INSPECTION DOORS BE CLEANED IF ANY CURVES AND ANY HORIZONTAL SECTIONS C THE CLEANING OF THE GENERATOR FREQUENCY IS APPROXIMATE THEY DEPEND ON THE QUALITY OF THE PELLETS USED AND THE FREQUENCY OF USE IT CAN HAPPEN THAT THESE OPERATIONS SHOULD BE PERFORMED MORE FREQUENTLY CLEANING AND MAINTENANCE BY THE USER Routine cleaning operations as specified in this use and maintenance manual must be performed with the utmost care according to the instructions procedures and frequency intervals described in this use and maintenance manual CLEANING THE SURFACES AND COVERING Never use abrasive or chemically aggressive detergents for cleaning The surface cleaning must take place when both the generator and the coating are completely cold For the maintenance of surfaces and metal parts simply use a damp cloth with water or mild soap and water Failure to observe the instructions may damage the surface of the generator and invalidate the warranty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The cleaning of the ceramic glass is allowed only when the
32. is key ENABLE DISABLE 6 CHRONO Pressing the key once will enable or disable the chrono The delayed switch off can be set by pressing this key 7 DELAYED SWITCH OFF For example if the stove is set to switch off in an hour it shall switch off ENABLING automatically once the set time elapses displaying the countdown every minute for delayed automatic shutdown This key allows to access the user and technical menu the technical 8 MENU i menu is reserved for assistance 9 INCREASE The temperature setting can be increased by pressing this key 10 ESC KEY The key allows the user to exit any program or display and returns to the main menu without saving the data 11 BACK The key returns to the display of the various menus 12 CONFIRMATION KEY This key confirms the adjustments made during the user menu programming phase 13 FORWARD The key allows to go forward in the various menus 14 ENABLE FUNCTION F1 Pre set key for future applications 15 DECREASE The key decreases the value to be set 16 STOVE STATUS Pressing this key will display the general status of the stove Important note the numbers shown on the remote control are purely indicative and are not present on the remote control supplied with the product TYPE AND REPLACEMENT OF BATTERIES The batteries are housed in the lower part of the remote control To replace them remove the battery holder as indicated in the figure at the back of the remote co
33. it is not possible to restore product conformity by repairing it the product component will be replaced the guarantee expiration date and conditions will remain the same established when the product component to be replaced has been purchased 4 Extraflame S p A cannot be held liable for injury or damage which may either directly or indirectly be caused to persons animals and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding installation use and maintenance of the product that can also be downloaded on the website 5 Interventions for adjusting and or regulating the product for the type of fuel or other reasons are excluded by the guarantee 6 If the product is repaired in one of the Authorised Technical Assistance Centres indicated by Extraflame S p A and if the product is replaced transport will be free of charge If the technician can repair the product at the user s place of residence and they refuse transport to the workshop and redelivery will be paid by the consumer 7 After the 24 months of the guarantee have elapsed any repair intervention cost will be completely borne by the consumer 8 In the case of disputes the only competent court is that of the Extraflame S p A registered office Vicenza ltaly 30 ENGLISH OExtraflame ADDITIONAL WARNINGS Only use the fuel recommended by the manufacturer The product must not be used as an in
34. latter is completely cold To clean the ceramic glazing simply use a dry brush and some damp newspaper dabbed in the ash If the glazing is very dirty only use a specific ceramic glazing detergent Spray a modest amount onto a cloth and wipe the ceramic glazing Do not spray cleaner or any other liquid directly on the glass or on the gaskets Failure to observe the instructions may damage the surface of the ceramic glass and invalidate the warranty CLEANING THE TANK PELLETS When the tank empties completely unplug the power cord from the generator and remove residues dust chips etc from the tank empty before filling it DAILY SCRAPERS Use the scrapers moving upwards for models with upper scrapers or pulling and pushing them for the inserts and models with front scrapers Please note scrapers are preferably used when the stove is cold if used when the stove is hot it is recommended to use special gloves to protect against the heat as they can get very hot ENGLISH 23 OExtraflame Open the door Clean the glass with a damp cloth Never spray the detergent or any other liquid used for cleaning directly on the ceramic glass CLEANING THE BURN POT AND COMBUSTION CHAMBER 1 Vacuum the residues in the burn pot 2 Take out the burn pot from the designated compartment 3 Vacuum the ash from the burn pot s seat and the combustion chamber 3 1 4 U
35. n the user and maintenance manual one ensures correct combustion in the generator over time thereby preventing any anomalies and or malfunctions that may require more work to be performed by the technician Requests for routine maintenance are not covered by the product s warranty DOOR ASH DRAWER AND BURN POT GASKETS The gaskets ensure the tightness of the stove and its consequent proper operation They must be checked periodically in the event they are worn or damaged they must be replaced immediately These operations must be carried out by a qualified technician CONNECTION TO THE FLUE Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections any residue must be removed before it obstructs the flue PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON At the end of every season before turning off the stove we recommend completely emptying the pellet tank and using a vacuum cleaner to clear up any pellets and dust residue inside it You should also disconnect the generator from the mains and to ensure greater safety especially if there are any children around remove the power supply cable Routine maintenance must be performed at least once a year C IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY QUALIFIED PERSON SO AS TO AVOID ALL RISKS The images are for illustration purposes
36. ning Indicator on weekly programming active Indicator off weekly programming disabled It indicates fumes motor operation Off fumes motor disabled On fumes motor active Flashing breakdown Indicates the stove modulation On the stove is working at the set power Flashing the power at which the stove is working is different to the power set the stove is modulating for various reasons It indicates tangential fan operation where applicable Off not working On working Flashing motor at minimum It indicates pellet feed motor operation Off pellet feed motor disabled On pellet feed motor active Indicates the presence of an alarm Triangle On 1 flashing key Indicates the presence of an alarm Indicates the compensation function Off the function is disabled On the function is active Indicates the room temperature status Off the T read by the probe is above the set temperature On the T read by the probe is below the set temperature Indicates the contact of the external additional thermostat the contact of the external additional thermostat is closed and the STBY function is active the contact of the external additional thermostat is closed and the STBY X function is disabled C Contact open Flashing with closed Contact closed contact the contact of the external additional thermostat is open and the STBY function is active the contact of th
37. ntract this guarantee will be void Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee Similarly are excluded defects related to incorrect operation of the flue according to the legislation in force in the country at the moment of purchase Other exclusions include all product defects due to carelessness accidental breakdown tampering and or damage during transport scratches dents etc interventions carried out by unauthorised personnel and further damage caused by incorrect interventions by the consumer trying to arrange the initial malfunction The following consumables are excluded by the guarantee gaskets ceramic or tempered glasses cast iron grilles or coatings refractory materials e g Nordiker or others painted chrome plated or golden parts majolica ware handles the brazier and its related components For Idro products the heat exchanger is not covered by the guarantee if a suitable condensation proof circuit is not set up to ensure a return temperature of the device of at least 55 C The guarantee excludes all the external components on which the consumer can directly operate during use and or maintenance or that can be subject to wear and or rust and stains on steel due to aggressive detergents If malfunctions are signalled which are not later confirmed during check by an authorised technician the cost of the intervention will be borne entirely by the consumer 3 If
38. ntrol remove or insert the battery following symbols on the remote control and on the battery For operation 1 CR2025 3V lithium buffer battery is required If the remote control is off because it has no batteries the stove can be controlled from the control panel on top of it While replacing the battery pay attention to the polarity by observing the symbol on the inside compartment of the remote control e The batteries used contain metals harmful for the environment They must therefore be disposed of separately in appropriate containers COMMISSIONING SETTINGS Once the power cable at the back of the stove has been connected move the switch also located on the back to 1 The switch at the back of the stove powers the stove board The stove remains off and a first screen appears on the panel reading OFF ENGLISH 15 OExtraflame MAINS FREQUENCY 50 60HZ In the event the stove is installed in a country with 60Hz frequency the stove will display frequenza rete errata Mains frequency incorrect Vary the frequency as described below CONTROLS PROCEDURE Press key 6 Select the frequency required using key 4 or 5 Press key 6 to confirm and key 1 to return to the previous menus up to the initial status ADJUSTING TIME DAY MONTH AND YEAR Set clock allows to adjust the time and date SET CLOCK DAY MON TUE WED SUN CONTROLS PROCEDURE HOURS 0 23 Press key 6 and SET CLOCK will appear MI
39. ny wooden beams located above the insert must be protected with non inflammable material Frame assembly is important as it allows correct recirculation of the air and consequently optimal product operation The 2 side frames are fixed to the upper frame by means of 2 screws each side The remaining holes on the side frames allow to fix the entire frame to the sides of the machine by means of self drilling screws CAN VOID THEWARRANTY AND THE RESPONSIBILITY OF THE MANUFACTURER C THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF YOUR STOVE AND OPEN THE TANK LID AND LOAD THE PELLETS USING A SCOOP IN THE EVENT OF THE INSERTS ONLY LOAD WHEN THE MACHINE IS OFF AND COLD BY EXTRACTING IT FROM THE COMPARTMENT IN THE EVENT OF INSTALLATION WITH FEEDING KIT OPTIONAL THE MACHINE MUST NOT BE EXTRACTED ENGLISH 11 OExtraflame FRONT TILTING DEFLECTOR The insert is supplied with a front deflector which must be opened before starting the insert If you attempt ignition with the deflector closed the screen will display GRATE CLOSED CAUTION DEFLECTOR OPENING Lift the deflector by the provided tang on the right side until blocking it in an open position See figure to the side DE
40. ograph of the chimney plaque 3 system booklet where applicable The installer must ask to be issued with a receipt stating that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s administrator must be requested COMPATIBILITY Installation in premises with fire hazards is forbidden Installation in residential premises except for sealed operation appliances is also forbidden in which there are liquid fuel operated appliances with continuous or intermittent operation which draw the combustion air in the room in which they are installed or in which there are type B gas appliances intended for room heating with or without production of domestic hot water and in adjacent and adjoining premises or in which in any case the depression measured during installation between the internal and external environment is greater than 4 INSTALLATIONS IN BATHROOMS BEDROOMS AND STUDIO FLATS Installation in bathrooms bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside POSITIONING AND SAFETY DISTANCES The support surfaces and or points must have a suitable capacity to bear the overall weight of the appliance accessories and coverings If the floor is made of a combustible material we recommending using a non c
41. ombustible material to protect the front part from any burnt material which might fall during routine cleaning operations The generator must be level to function properly The adjacent side and rear walls and the supporting surface must be made of non combustible material Installation adjacent to combustible or heat sensitive materials is allowed as long as there is a suitable safety distance in between which for pellet stoves is REFERENCES INFLAMMABLE OBJECTS NON INFLAMMABLE OBJECTS Air inlet floor protection INSTALLING INSERTS When installing inserts access must be prevented to the internal parts of the appliance and it must not be possible to access live parts during extraction operations Any wiring for example the power cable or room probe must be positioned so as not to be damaged during movement of the insert and must not come into contact with hot parts VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation is deemed sufficient when the room is equipped with air inlets according to the table Percentage of the Appliance categories Reference standard net opening section with respect to the appliance fumes outlet section Minimum net opening value of the ventilation duct UNIEN 14785 UNI EN 303 5 In any case ventilation is deemed sufficient when the pressure difference between the external and internal environment is equal to or less than 4 Pa ENGLISH 5 OExtr
42. operations have been performed The stove is modulating COOLING STAND BY BLACK OUT The stove is cooling due to black out Room thermostat set at minimum value In this mode the stove only works at 1st power independently from the power set To exit this function just raise the room temperature using button 4 and then key 2 Room thermostat set at maximum value The stove works at the set speed without ever modulating To exit this function just lower the set temperature using button 4 and then key 1 PELLETS The PELLETS LOW message combined with key 1 flashing slowly indicates that the pellets tank is at minimum LOW With the machine switched off and fully cooled down load the pellets tank ALARMS DISPLAY EXPLANATION SOLUTION On and flashing indicates the presence of an alarm The alarm can be reset by pressing button 3 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed The fixed triangle on the display and key 1 flashing slowly indicate the presence of an alarm ENGLISH OExtraflame Indicates the presence of an alarm Fault correlated to the flue gas exhaust motor FUMES PROBE Fault correlated to the fumes probe ALARM FUMES OVERHEATING ASPIRAT FAULTY The flue gas temperature has exceeded 310 C bottom are dirty The door is not closed correctly The ash drawer is not closed correctly The depression sensor is f
43. play By default set on OFF the display and keys backlight will switch off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine By setting between 10 and 31 adjust the lighting intensity of the display 10 minimum brightness 31 maximum brightness and the backlight always stays active CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear 410 e Press key 2 several times until USER is displayed e Press key 6 DISPLAY will appear Use keys 4 5 to select the brightness of the display OFF Press key 6 to confirm and key 1 to return to the previous menus e 225 C 14 10 up to the initial status li PELLET FEED ADJUSTMENT The following menu allows to adjust the percentage of pellet feed If the stove has functioning problems owing to the quantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories NO FUEL 18 ENGLISH OExtraflame the stove can never develop a suitable flame tending to remain very low even at high powers at minimum power the stove tends to almost switch off taking the stove into PELLETS alarm condition when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL the stove develops a very high flame even at low power the panoramic glass is
44. pplied Allen key to turn the screw at the bottom left corner clockwise To understand whether the insert is correctly attached to the base connect the plug to the socket and make sure the display switches on Mount the hopper support for the pellet and insert it into the relevant coupling N B If our pedestal is used a slot must be created in the flue that allows the pellet level in the feed box to be checked thus preventing spillage during filling Primary air PRIMARY AIR VENT intake pipe IT MUST NOT SUCK IN OVERHEATED AIR THE AIR VENT MUST BE MADE OUTSIDE THE FLUE AS PERFORMING THIS CONNECTION INCORRECTLY CAN JEOPARDISE PRODUCT OPERATION FRONT PELLET FEEDING KIT OPTIONAL The optional pellet feeding kit allows pellets to be fed into the feed box from the front without having to extract the insert operation that requires machine switch off Further information on the accessories is available on the website in the category accessories AIR CIRCULATION PIPES Create air recirculation inside the structure that covers the insert for correct operation This prevents the appliance from over heating To guarantee this just make one or more openings in the lower and upper parts of the covering 8 ENGLISH OExtraflame The following measurements must be respected LOWER PART COLD AIR INLET WITH TOTAL MINIMUM SURFACE 550 CM UPPER PART HOT AIR OUTLET WITH TOT
45. ress key 2 several times to reach SET USER Confirm using key 6 Press key 2 several times to reach STAND BY Using key 4 5 select at ON Press key 6 to confirm and key 1 to return to the previous menus up to the initial status The STAND BY function is active KEYS LOCKED The menu allows to lock the display keys like with mobile phones With the function engaged every time a key is pressed KEYS LOCKED will appear CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 DISPLAY will appear Press key 2 until KEYS LOCKED appears Use keys 4 5 to select enable disable Press key 6 to confirm and key 1 to return to the previous menus up to the initial status ia ONCE THE FUNCTION IS ACTIVATED USE KEYS 1 AND 5 AT THE SAME TIME TO LOCK OR UNLOCK THE KEYBOARD 20 ENGLISH OExtraflame V2 AIR The menu allows to adjust the speed of the ducted fan in percentage CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear 7 Press key 2 several times until USER is displayed e Press key 6 Press key 2 until V2 AIR appears Use keys 4 5 to increase 4 or decrease 5 A Press key 6 to confirm and key 1 to return to the previous menus up to the 2 initial status RESET Allows to reset all values modifiable by the user to the default values The modified data is the following CONTR
46. ric shocks Installations not complying with the regulations in force as well as incorrect use and failure to comply with the maintenance scheduled by the manufacturer will invalidate the guarantee 9 9 ENGLISH 31 CIExtrafiame Riscaldamento a Pellet EXTRAFLAME S p A Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY FN 39 0445 865911 2 39 0445 865912 infogextraflame it EJ www lanordica extraflame com The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties 30 04 2015 004276341 COMFORT PLUS CRYSTAL 004R
47. rsons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed One must also bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed as well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY THE GENERATOR MUST NOT BE USED BY PERSONS INCLUDING CHILDREN WITH REDUCED PHYSICAL SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN MUST BE CHECKED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE DO NOT TOUCH THE GENERATOR WHEN YOU ARE BAREFOOT OR WHEN PARTS OF THE BODY ARE WET OR DAMP THE SAFETY AND ADJUSTMENT DEVICES MUST NOT BE MODIFIED WITHOUT THE AUTHORISATION OR INDICATIONS OF THE MANUFACTURER
48. s are guaranteed within the European community for 24 months from the date of purchase Purchase has to be proved by means of a valid fiscal document issued by the seller receipt invoice or shipment document identifying the purchased product and its purchase and or delivery date WARNING This conventional guarantee does not replace the guarantee regulated by the European legislation on consumer rights The conventional guarantee is only applicable to the Italian region and to those areas within the European Community where the Authorised Technical Assistance Centres are active see the www lanordica extraflame com website It is also limited to the state of residence of the consumer which must coincide with the premises and or registered office of the seller of the Extraflame S p A product These regulations do not apply if the product is purchased within commercial entrepreneurial or professional circumstances In these cases the product guarantee will be limited to a period of 12 months from the date of purchase ITALIAN GUARANTEE What must be done if there is a product malfunction Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly Make sure the malfunction is included in those covered by the guarantee otherwise the cost of the intervention will be borne entirely by the consumer When requesting the intervention of the Assistance service at the Authorised Assistance Centre alway
49. s specify type of malfunction model of the appliance complete address phone number EUROPEAN GUARANTEE What must be done if there is a product malfunction Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly Make sure the malfunction is included in those covered by the guarantee otherwise the cost of the intervention will be borne entirely by the consumer Request the intervention of the Assistance service or the address of the Authorised Technical Assistance Centre to the seller always specify type of malfunction model of the appliance complete address and phone number If the malfunction arises in the first 6 months of the product s life the consumer has the right to have the product repaired with no expense From the seventh to the twenty fourth month if a malfunction arises the consumer will bear the cost of the call while the seller will pay for the manpower and for any spare parts used 2 If the malfunction is linked to external events and or conditions such as including but not limited to insufficient capacity of the systems wrong installation and or maintenance by the personnel which hasn t got the skills prescribed by the laws of the country of residence of the consumer negligence inability to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales co
50. se the special poker supplied to clear the holes in the burn pot 5 Place back the burn pot and push it towards the hearth wall 6 If there is an ash collector tray vacuum the ash deposits PLEASE NOTE USE A SUITABLE VACUUM CLEANER WITH A SPECIAL CONTAINER TO SEPARATE THE COLLECTED ASH VA eras F De z 4 E 4 cam HE EL gt a 4 Wee i 14 4 gt 3 x HN reu Hd v 7 bue 111 15 d dixi 1 d a re 12 23 ee j 1 dta PE Jol j d d 7 i ENGLISH OExtraflame EVERY 3 4 DAYS WEEKLY ASH DRAWER Every 3 4 days check the ash drawer and empty it at least one twice a week If there is a lower door open remove it Take out the removable ash drawer and empty it in a special container Vacuum the area underneath the removable ash drawer Once you have cleaned it place back the removable drawer and close place back the external door In some stoves the ash collector tray is located in the combustion chamber In this case just open the door and vacuum the ash from the tray pi t of We Ka ant 1 dni M yo y ail acl MONTHLY CLEANING THE HEAT EXCHANGER The heat exchangers chamber must be cleaned every month as the soot deposited on the rear of the he
51. very dirty obscuring it almost totally the burn pot tends to become encrusted blocking the holes for air intake due to the excessive pellet feed as it is only burned partially The adjustment to be performed is in percentage Therefore changing this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 20 to 30 Follow the procedure on the display to perform the procedure CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Presskey 6 DISPLAY will appear key 2 until PELLET appears Use keys 4 increase 5 to 4 or decrease 5 the load during the WORK stage Press key 6 to confirm and key 1 to return to the previous menus up to the initial status V1 AIR The menu allows to adjust the speed of the front fan in percentage CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed 7 e Press key 6 DISPLAY will appear 3 Press key 2 until V1 AIR appears Use keys 4 5 to increase 4 or decrease 5 A 1 e Press key to confirm and key 1 to return to the previous menus up to the initial status STAND BY STAND BY WITH DIGITAL THERMOSTAT STANDARD STBY FUNCTION SET AT ON If the Stby function is active ON when the stove reaches the set room temperature and exceeds it by 2 C it will switch off after a d
Download Pdf Manuals
Related Search
Related Contents
Manuale Utente User Manual DIAMOND143 Page 1 Radiateurs au gasoil* ultraportables Manuel / . / Version 2.0 Notice d´Utilisation Gebruiksaanwijzing Caliber C 12150 Samsung MM-E460D Benutzerhandbuch MANUEL D`INSTRUCTIONS - Zone Owner / Operator and Safety Manual Iron & Oak Hydra Logitech K290 Copyright © All rights reserved.
Failed to retrieve file