EMCenter™ Modular RF Platform Model 7000-001 - ETS

image

Contents

1. 31 8 0 Remote Control of the EMCenter 33 First Character Identifier sese 33 Second Character Device ID Number 34 Command Examples nennen nennen 35 Example 1 Request Device Identification sssssssss 35 Example 2 Request an E Field Headng 35 Example 3 Request a Power Value 35 Command Set and Error Codes 36 ell ul KE 36 Errok CodeS aciona ees tee led ae ees tle esos taht ce oc gett 36 Appendix A Warranty eene 39 Appendix B EC Declaration of Conformity 41 Notes Cautions and Warnings Note Denotes helpful information intended to provide tips for better use of the product Caution Denotes a hazard Failure to follow instructions could result in minor personal injury and or property damage Included text gives proper procedures Warning Denotes a hazard Failure to follow instructions could result in SEVERE personal injury and or property damage Included text gives proper procedures See Laser Safety on page 17 for detailed laser safety precautions and operational features See the ETS Lindgren Product Information Bulletin for safety regulatory and other product marking information This page intentionally left blank vi 1 0 Introduction For flexible configuration of an EMC test facility and fully automated testing
2. EMCenter has its own safety interlock system which is connected in series with the interlock system of every installed card Additionally the following safety measures are implemented 18 The EMCenter is equipped with a remote interlock system For example this interlock system would prevent inadvertent laser radiation by preventing someone from entering a shielded room and stepping on a fiber To prevent accidental activation of the laser an Acknowledge button will appear directly after the Laser Start button is pressed The laser will start only if this button is pressed within a four second timeframe A visual Laser On indicator warns the operator of laser activity The Laser On LED on the front panel of EMCenter indicates that at least one laser is active 5 0 EMCenter Controls and Connectors Never disconnect the fiber optic cables when CAUTION one of the lasers is active gt See Manual Control of the EMCenter on page 25 for information on using the touchscreen controls Front Panel AETS LINDGREN EMCenter VETS LINDGREN EMCenter STATUS INDICATORS There are four status indicators on the front panel of the EMCenter Modular RF Platform e Interlock llluminates if the external interlock is open or if one of the plug in card interlocks encounters an interlock error D Laser On llluminates if at least one of the lasers in one of the cards is active e Standby llluminates when the
3. control and laboratory use Technical Construction Files are available upon request 41
4. eye Direct or even reflected light will cause permanent eye damage INVISIBLE LASER RADIATION Do not stare into beam or view directly with optical instruments Avoid eye or skin exposure to direct or scattered radiation gt Some EMCenter Modular RF Platform plug in cards use a high power laser to supply energy to a remote floating measuring device The wavelength of these lasers is approximately 808 nm These lasers are high power infrared lasers and invisible to the human eye Please read the documentation and safety instructions provided in the separate manual for the specific card 17 Exposure to any laser radiation during normal operation is not likely because the EMCenter uses only fiber coupled lasers However for the safety of all employees please comply with the following rules When the EMCenter is not in use power off the unit The remote interlock connection should be connected to an emergency master disconnect and in series with the room door or fixture interlocks Connect all fiber cables and install protective covers before switching on the system Protective covers are identified by the following label Do not attempt to turn on the EMCenter if the fiber optic cables show any sign of damage Safety Features To make the EMCenter as safe as possible the primary safety system of each plug in card is designed to work standalone without any intervention from the EMCenter Apart from this the
5. Can 11 Standard Configuration need te b te dg nest 11 ETS Lindgren Product Information Bulletin eeeeeeeeeeeereeereeeernere 12 2 0 Maintenance eere eren 13 Maintenance of Fiber Optics recent 14 Service Procedures actives et ete Eed ere trades 14 3 0 Specifications eere 15 Performance Specifications AAA 15 Physical Specifications si rien otis tie be dp dede tantes 15 Environmental Specifications eenn 15 Power Gpechflcailons esses eene Interface and Cable Specifications 4 0 Laser Safety nennen Satety Precautions isa e e Ree ae ERE 17 Safety Features 5 0 EMCenter Controls and Connectors 19 Front Rome geht eye eere e E Ie gue Fa ue Eet 19 Stat s Indicators ern nee e ec are 19 sedat 20 6 0 Installation 2 iren aeree Ee 23 Plug In Card Installation 23 7 0 Manual Control of the EMCenter 25 Common Control Buttons 25 Powering On and Off essen eee abre nile dace 26 a UE e D 26 Power Ofi xc orders chats nda A SD stie MEGAS au dE Recettes voe ey 27 attente EE 28 Home Screens sis Shins a ERE HH ae 29 Card Slot Numbers nemen 29 Slats E 30 Control Buttons 30 Local Mode tea t NL e dire 30 Configuration Screen oie eese heats
6. EMCenter Modular RF Platform User Manual SEIS LINDGREN An ESCO Technologies Company ETS Lindgren Inc reserves the right to make changes to any product described herein in order to improve function design or for any other reason Nothing contained herein shall constitute ETS Lindgren Inc assuming any liability whatsoever arising out of the application or use of any product or circuit described herein ETS Lindgren Inc does not convey any license under its patent rights or the rights of others Copyright 2013 2014 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark and EMCenter EMSwitch EMPower EMControl EMSense EMLink TILE and EMQuest are trademarks of ETS Lindgren Inc Revision Record MANUAL EMCenter Part 399342 Rev B Revision Description Date A Initial Release July 2013 B Updated EMCenter models June 2014 Table of Contents Notes Cautions and Warnings en V 1 0 Introduction eeeeeeeeeeeeeeeeeeeennrennn nnn 7 EMCenter Plug In Cards Optional 8 EMSwitch RF Switch Plug In Card 8 EMPower Plug In Card and EMPower Sensors sssi 9 EMControl Positioner Control Plug In Card 10 EMSense EMF Probe Plug In Can 10 EMGen RF Signal Generator Plug In
7. EMCenter is in standby mode D Power On Illuminates when the EMCenter is turned on 19 Back Panel ee Lee e Slots 1 through 7 Allow you to install a combination of ETS Lindgren plug in cards EMSwitch EMPower EMControl and EMSense For more information on the cards see EMCenter Plug In Cards Optional on page 8 e Slot 8 Dedicated to the processor card for the embedded Linux computer The processor card also provides these connectors RS 232 Serial interface bus to interface with a computer Use a straight pin for pin cable with sub D9 connectors The baud rate is 57k6 with no parity 8 bits and 1 stop bit LAN Local Area Network connection used to update the operating system and application software on the EMCenter USB e USB A USB device connection for a pointing device or keyboard e USB B The EMCenter can act as a USB device when connected to a computer 20 e Slot 9 Dedicated to the power supply card The power supply card also provides a connection for an external interlock Interlock Safety interlock connection that provides two floating contacts which require shorting for the EMCenter to operate Use the supplied connector 6 3 mm 1 4 in stereo jack to wire to the emergency switch of your site Connect the tip and middle pin Mains Inlet Used to connect to the mains power to the EMCenter This IEC inlet holds a primary fuse A
8. d in flash making it easy to upgrade to new versions and future functionality EMCenier Plug In Cards Optional EMSwirCH RF SwiTCH PLUG IN CARD EMSwitch is a general purpose multi channel switch matrix used to switch the RF path of equipment for RF measurement applications including immunity emissions and wireless measurements EMSwitch is available with two SPDT coaxial relays four SPDT coaxial relays or two SP6T coaxial relays a 40 GHz option is also available EMSwitch cards switch RF signals from DC 18 GHz with powers up to 240 W Model 7001 001 Model 7001 003 Model 7001 002 not all models shown EMPOWER PLUG IN CARD AND EMPOWER SENSORS The EMPower Meter Plug in Card occupies one slot in the EMCenter and includes four USB ports accommodating any combination of up to four EMPower USB RF Power Sensors Two versions of the EMPower sensors are available e Model 7002 002 and Model 7002 004 Support RMS measurements for CW signals D Model 7002 003 and Model 7002 005 Measure RF bursts as short as a few microseconds The 7002 002 and 7002 003 sensors cover the 9 kHz to 6 GHz range and the 7002 004 and 7002 005 sensors cover the 80 MHz to 18 GHz EMCONTROL POSITIONER CONTROL PLUG IN CARD EMControl is a versatile positioner controller which enables you to synchronize the simultaneous movements of up to two ETS Lindgren positioning devices for example towers or turntables and the on off operation of a
9. dentifier for the EMCenter Modular RF Platform cards Plug in Card Identifier Description 7004 004 P Dual Laser Power Supply Card 7001 00n S EMSwitch Card All 7004 00n L lt Future use gt 7003 00n G lt Future use gt 7002 001 X EMPower Meter Plug in Card 7002 00n Ww EMPower Sensor All 7006 001 EMControl Positioner Control Plug in Card 7007 001 EMSense EMF Probe Plug in Card Battery 33 Second Character Device ID Number Each card in the EMCenter is assigned a unique device ID number that is the same as the slot number all commands for plug in cards must be preceded by the numbered slot where the card is installed Additionally if the card provides a multiple port like EMPower the port number must also precede the command A carriage return CR must terminate each command gt Looking at the back of the EMCenter the card slots are numbered 1 to 7 from left to right For example if the EMCenter was installed with the following cards you would configure the device drivers of the external software with the device ID numbers shown in the table Card Slot Number Port Number Plug in Card Type Device ID Number 1 EMSwitch 2 EMLink 3 EMPower 3 A EMPower 3 B EMPower 3 C EMPower 4 D EMPower 5 EMSense 6 Empty 7 Empty 8 Processor 9 Power Supply 34 If a card slot supports more than one device the
10. device ID is the slot number followed by the port number of that card slot For example using the previous table H To access the second EMPower in slot 3 Use device ID number 3B H To access the EMLink in slot 2 Use device ID number 2 Command Examples EXAMPLE 1 REQUEST DEVICE IDENTIFICATION To request the identifier of the EMSwitch card in slot 1 1 IDN EXAMPLE 2 REQUEST AN E FIELD READING To request an E field reading from the EMSense card in slot 4 4 D2 EXAMPLE 3 REQUEST A POWER VALUE To request a power value from the EMPower sensor connected to port B of the card in slot 3 3B POWER 35 Command Set and Error Codes Following are the general commands and error codes for the EMCenter For device specific commands see the separate manual for each card COMMAND SET Command Message Description IDN Request the identification of the EMCenter Response ETS Lindgren EMCenter version x x xx STATUS Request the status of the EMCenter reply is device specific LOCAL Return to local mode REBOOT SYSTEM Reboot the EMCenter ERROR CODES Error Code Description ERROR 1 Internal buffer overflow ERROR 2 Command too long ERROR 3 Invalid command ERROR 4 Command too short ERROR 5 Invalid parameter ERROR 6 Parameter too high ERROR 7 Parameter too low ERROR 8 Hardware failure ERROR 9 Reserved ERROR 10 Reserved ERROR 20 U
11. e EMCenter Home Screen 26 POWER OFF 1 Press the Off button located on the EMCenter screen EMPower 7002 001 i isa d EMSwitch 7001 001 EMSwitch 7001 021 EMSense 7007 001 EMControl 7006 00 EMSense 7007 002 Standby Press to start 30 000 000 MHz RF OFF 2 Press OK to switch off the system The standby light located on the front panel of the EMCenter will flash and then will illuminate steadily gt When the EMCenter is in standby mode touch the screen anywhere to reboot 3 Tum the power switch located on the back panel of the EMCenter to the off position Remove the power cord from the power connector on the back panel of the EMCenter 5 Remove the interlock jack from the interlock connector on the back panel of the EMCenter 27 Information Screen Press Info to display the Information screen EMCenter C Home Modular RF Platform Back EMCenter Version 1 7 1 IEEE address 4 Slott EMPower 7002 001 4 1 3 Slot2 EMSwitch 7001 001 3 5 1 Slot3 Available Slot4 Slot5 Slot6 Slot7 Available www emcenter info Config Sample Information Screen The Information screen displays after the EMCenter is powered on It provides the following information e Software version e Configured IEEE address if installed e Plug in card installed in each slot 28 Manual C Home Screen Press Home to display the Home screen EMPowor 7002 001 63 1 8 pres
12. lways use the correct fuse when replacing the fuse The main power switch is also located on the IEC inlet 21 This page intentionally left blank 22 6 0 Installation Before connecting any components follow the safety information in the ETS Lindgren Product Information Bulletin included with your shipment If you plan to operate the EMCenter manually software installation is gt not required The EMCenter Modular RF Platform may be controlled from a computer using these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software Plug In Card Installation Leave an empty slot or space 1U in height CAUTION beneath the EMCenter to allow sufficient cooling through the bottom air inlets of the cabinet 1 Install each plug in card per the detailed installation steps provided in the separate manual for the specific card 2 See Power On on page 26 and follow the instructions to turn on the EMCenter The EMCenter is now ready for use You can control all cards through the touchscreen See page 25 for information on using the EMCenter touchscreen 23 This page intentionally left blank 24 7 0 Manual Control of the EMCenter Before placing into operation follow the safety information in the ETS Lindgren Product Information Bulletin included with your shipment Prior to operation verify tha
13. n Option is available when the EMCenter is connected to a computer 30 Configuration Screen Press Config to display the Configuration screen The IEEE address of the EMCenter can be changed here IEEE Board Enabled Home IEEE address 4 1 Up Back IP address FALLA FEE Change info Gateway address 192 168 8 1 Change Touchscreen Calibrate Calibration Screen Laser Protection Code MUI Sample Configuration Screen e IEEE Board Press Change to enable or disable the board if installed e IEEE Address Press Up or Down to change the address if installed e IP Address Press Change to set a new address e Gateway Address Press Change to set a new address e Touchscreen Calibration Press Calibrate Screen and follow the on screen instructions e Laser Protection Code Press Change to enter or change a code www ets lindgren com Manual Control of the EMCenter 31 This page intentionally left blank 32 8 0 Remote Control of the EMCenter gt To control a device installed in the EMCenter from a remote computer the IEEE address of the EMCenter must be set correctly All commands for plug in cards must have a two character prefix e First character Identifies the type of card e Second character Provides the device number of the card Terminate each command with a carriage return CR First Character Identifier The following table provides the first character or i
14. n WVGA 800 x 480 Processor 800 MHz Vortex 860x CPU Memory 256 MB DDR2 RAM 512 MB Flash Operating System Linux Configuration Desktop or 19 in rack mountable Physical Specifications Height 3U 132 mm 5 2 in Width 447 mm 17 6 in Depth 350 mm 13 8 in Controller Weight approximate 7 kg 15 4 Ib Environmental Specifications Temperature Range 0 C to 40 C 32 F to 104 F Relative Humidity 10 to 90 non condensing 15 Power Specifications Supply Voltage 115 230 VAC Power Consumption e Standby lt 1 0W e Empty 33 W e Max load 200 W Fuses 2AT Interface and Cable Specifications Interfaces e RS 232 e USB e Ethernet e GPIB IEEE 488 Connectors e IEC Inlet e Sub D 9 e USB A 2 0 2 e USB B 1 1 e Ethernet e GPIB IEEE 488 e Interlock Cables e RS 232 e EC power cord Interlock External interlock and interlocked laser outputs 16 4 0 Laser Safety For additional safety information see the ETS Lindgren Product Information Bulletin included with your shipment Safety Precautions LASER RADIATION AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT WAVELENGTH 808 nm OPTICAL POWER 0 5 W Never look into any of the fiber optic connectors The laser emits an infrared beam that is invisible to the naked
15. n additional auxiliary device such as a LISN or EUT EMSENSE EMF PROBE PLUG IN CARD The EMSense card provides an interface for ETS Lindgren battery powered EMC field probes Each EMSense card can support one probe 10 EMGEN RF SIGNAL GENERATOR PLUG IN CARD The EMGen card is a modular signal generator with AM and pulse modulation covering a frequency range of 9 kHz to 6 GHz EMGen is designed for EMC testing and quickly and accurately performs EMC tests without the need for an external modulation source Standard Configuration gt Standard configuration may vary by EMCenter model contact ETS Lindgren for additional information e EMCenter Modular RF Platform e Cables RS 232 USB power e Interlock plug e Mains lead e 19 inch mounting brackets 11 ETS Lindgren Product Information Bulletin See the ETS Lindgren Product Information Bulletin included with your shipment for the following 12 e Warranty information e Safety regulatory and other product marking information Steps to receive your shipment e Steps to return a component for service e ETS Lindgren calibration service e ETS Lindgren contact information 2 0 Maintenance CAUTION WARRANTY Before performing any maintenance follow the safety information in the ETS Lindgren Product Information Bulletin included with your shipment Maintenance of the EMCenter is limited to external compone
16. nknown device type ERROR 21 Unknown device number 36 Error Code Description ERROR 22 No reply from device ERROR 23 No such device ERROR 100 EMSense probe not connected laser off ERROR 101 EMSense probe busy zeroing 37 This page intentionally left blank 38 Appendix A Warranty See the Product Information Bulletin included with your shipment for gt the complete ETS Lindgren warranty for your EMCenter DURATION OF WARRANTIES FOR EMCENTER All product warranties except the warranty of title and all remedies for warranty failures are limited to three years Product Warranted Duration of Warranty Period EMCenter Modular RF Platform 3 Years 39 This page intentionally left blank 40 Appendix B EC Declaration of Conformity ETS Lindgren Inc declares these products to be in conformity with the following standards following the provisions of EMC Directive 2004 108 EC and Low Voltage Directive 2006 95 EC EMCenter Modular RF Platform Emission EN 61326 1 2006 Class A Electrical equipment for measurement control and laboratory use Note Conducted emission complies with Class B household equipment Immunity EN 61326 1 2006 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Safety EN 61010 1 2010 Safety requirements for electrical equipment for measurement
17. nts such as cables or connectors Clean the exterior of the cabinet using a damp cloth and mild cleaner Always unplug the unit before cleaning To prevent electrical shock do not remove cover Warranty may be void if the housing is opened If you have any questions concerning maintenance contact ETS Lindgren Customer Service 13 Maintenance of Fiber Optics Fiber optic connectors and cables can be damaged from airborne particles humidity and moisture oils from the human body and debris from the connectors they plug into Always handle connectors and cables with care using the following guidelines Before performing any maintenance disconnect the fiber optic cables from the unit and turn off power When disconnecting fiber optic cables apply the included dust caps to the ends to maintain their integrity Before connecting fiber optic cables clean the connector tips and in line connectors Before attaching in line connectors clean them with moisture free compressed air Failure to perform these tasks may result in damage to the fiber optic connectors or cables Service Procedures For the steps to return a system or system component to ETS Lindgren for service see the Product Information Bulletin included with your shipment 14 3 0 Specifications Performance Specifications Slots 2 to 7 modular card slots depends on model Display e TFT with touchscreen e 7 0 i
18. s rss 1 om EMSwitch 7001 001 cc Available Info Available Available Avaliable Available Sample Home Screen CARD SLOT NUMBERS Looking at the back of the EMCenter the card slots are numbered 1 to 7 from left to right The numbers 1 to 7 on the left side indicate the card slot numbers of the EMCenter In this example the following cards are installed e Slot 1 EMPower e Slot 2 EMSwitch No cards are installed in slots 3 7 www ets lindgren com Manual Control of the EMCenter 29 STATUS BOX A status box for each slot displays to the right of the slot number The box displays an overview of the main parameters for each installed card This can be the actual field strength for a field probe or the positions of the different switches in case of an EMSwitch plug in card If no card is installed in a slot the Status box will display Available To display or change the data and configuration parameters of a card press the Status box for that card CONTROL BUTTONS Depending on the card installed relevant control buttons will appear These buttons are used to start the card or to control the status of the card See the separate manual for the specific card for more information For a description of common control buttons see page 25 LocAL MODE Local control is disabled once the EMCenter has been operated by remote To regain local control press Go to local in the bottom right of the Home scree
19. t the mains voltage is within the operating range of the equipment SETS LINDGREN EMCenter ii EMCenter Common Control Buttons The following control buttons are common to most EMCenter Modular RF Platform screens if relevant to the particular screen e Home Press to display the Home screen See page 29 for information on the Home screen e Back Press to display the previous screen e Info Press to display the Information screen See page 28 for more information e Config Press to display the Configuration screen See page 31 for more information on the Configuration screen e Off Press to power off the EMCenter See page 26 for the steps to power on and power off 25 Powering On and Off POWER ON Verify all cards are installed correctly in the EMCenter 1 Plug the power cord from the mains inlet on the back panel of the EMCenter into a power outlet 2 Plug the interlock jack into the interlock connector on the back panel of the EMCenter 3 Turn the power switch located on the back panel of the EMCenter to the on position 4 Touch anywhere on the EMCenter screen It will take approximately 20 seconds to boot The Information screen will flash and then the Home screen will display MSwitch 7001 001 NC NC EMSWiten 001 021 EMSense 7007 001 No probe EMControl 7006 001 358 9 100 0 cm MSense 7007 002 Standby Press to start 30 000 000 MHz RF OFF Sampl
20. the ETS Lindgren EMCenter Modular RF Platform provides space for up to seven plug in cards in a 3U 19 inch rack mount enclosure The EMCenter can also be used as a desktop unit AETS LINDGREN EMCenter SETS LINDGREN EMCenter The EMCenter is available in the following configurations e Model 7000 001 7 slot EMCenter Modular RF Platform e Model 7000 010 7 slot EMCenter Modular RF Platform with GPIB D Model 7000 011 2 slot EMCenter Modular RF Platform with GPIB The slots can contain a user defined combination of these ETS Lindgren cards EMSwitch EMPower EMControl and EMSense When installed each card is automatically recognized initialized and ready for use For more information on the cards see EMCenter Plug In Cards Optional on page 8 The EMCenter is configured and controlled using the 7 in widescreen color thin film transistor TFT touchscreen on the front panel Additionally the EMCenter may be controlled from a computer using these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software e Other test automation software The EMCenter contains a Vortex embedded main processor to control all cards and to interface with the user and or an external computer The operating system is Linux based providing a stable operating environment fast startup time and high performance All embedded software is store