1. IndustrialPro Series Router User Manual METHOD 2 PC to LAN ETH1 R3000 Series only e Select Use the following IP address and fill in the blank fields with the information below e IP address 192 168 1 2 e Subnet mask 255 255 255 0 e Default gateway 192 168 1 1 e Preferred DNS 192 168 1 1 You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings 6 Obtain an IP address automatically Use the following IP address IP address 192 168 1 Default gateway 197 168 1 Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server 197 168 1 1 Alternate DNS server Click OK e The previous screen will appear Click OK N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Hipay business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Verify that you are connected to the Sixnet router e Open a Command Prompt window on your laptop o XP gt Start gt Run type in cmd and lt Enter gt Type the name of a program Folder document or fj Internet resource and Windows will open it For you Open bi o Vista Windows 7 Start gt Search window just above the Start type in cmd wait for Vista Windows 7 to
2. o Z lt Connection Tracking SYN Tx timeout 65 TCP Keep Alives WEE 3600 Enter Maximum Probe Attempts MTU ar1s e em BOM am NO default v Toll Free 800 489 7781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support Gateway R3300B G Copyright 2012 Sixnet Inc Connection Tracking SYN Tx Timeout Specifies the timeout value in seconds for SYN packets for connection tracking 65 is the generally recommended default which differs from the system default of 120 30 120 is the recommended tuning range for IP ATMs TCP Keep Alives Enter Timeout Specifies the amount of time in seconds that a TCP connection can remain in an idle state before sending Keep Alive Probes to verify that the remote end of the socket is still available 10 30 for Ethernet connections where data usage is not an issue 60 300 for Cellular connections where total data usage must be considered NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Enter Maximum Probe Attempts Specifies the acceptable number of failed probes that will be sent to the remote end of a TCP socket before determining the connection to be failed and disconnecting Recommended values are 3 6 MTU Enable Path MT
3. Enable traffic restrictions ves Traffic Restrictions Select method of traffic restriction None Subnet 10 100 100 0 24 Sixnet Wireless r Toll Free 800 489 7781 r i Fax 314 476 0007 1645 LaGuardia Drive Web wwwjbmetectionics com SL Louis MO 63134 Wwww sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says IP Transparency settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says IP Transparency settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 6 3 Out of Band Management Sixnet Cellular Routers in the IndustrialPro and EnterprisePro series support out of band management via the Advanced menu The Out Of Band Mgt menu item allows you to configure the capability of remotely administrating a third party device connected via a serial cable on the Sixnet router Status Admin Networking Services Advanced IF Fallback IP Transparency Installed Firmware Version O
4. option and the following window will appear Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Enable Ping Alive Test Interval in minutes Test Packets to Send E i Required Allowable Packet Loss kegured PRUETT seeieeeiele ee 92 168 10 195 Required Source Interface Beie 192 168 6 20 Failure Command Script cancel J Apply_ Source IP Address eo 8 fs fe fre ee re ev Sixnet Wireless Toll Free 800 489 7781 4645 LaGuardia Drive re i Fax 314 426 0007 St Louis MO 63134 ee Web www sixnet com Copyright 2010 Sixnet LLC Test Interval in minutes Enter the time interval in minutes to which the ping packets would be sent Recommended setting is 50 Test Packets to Send Specify the number of ping packets to send out to test connectivity The minimum is 1 maximum is 10 Allowable Packet Loss Specify the number of lost packets that are acceptable before the link is considered unavailable Note The value must be less than the number of test packets set via Test Packets to Send Host Address Enter the IP Address of the destination host to which the ping packet would be sent Default setting is 1 0 0 1 Source Interface Select the name of the interface to which th
5. Firewall Rules Firmware Version Number Device Serial Number Serial Number System Pre Physical Interface Status Connection State IP Address Link Status System Information Up 192 168 111 1 Down Up 192 168 8 20 Up System Services Syslog Update History Ping IP Address 166 130 12 34 Signal Strength UMTS 90 Connection Enabled we eee ee 2 oe 2 pppo Socket Test Speed Test Disabled v 2 Selec Traceroute Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 Toll Free 800 489 7781 Fax 314 426 0007 Web www sixnet com Copyright 2010 Sixnet LLC T 415188775173 F 1 51 877 8346 IndustrialPro Series Router User Manual e Click on Speed Test option the following screen will appear Status Admin Networking Services Advanced Enter notes to be included with the test results in the box provided below Sixnet Wireless g 3 Toll Free 800 489 7781 4645 LaGuardia Drive Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copyright 2010 Sixnet LLC e Click the Start button which will begin the speed test Depending on the bandwidth of the connection under test this can take up to 30 minutes When finished the speed test will generate report of the latency and bandwidth results for this test These results will vary widely based on cellular techno
6. Hee Pa a a lime Novatel E725 Enabte Modem Auto Detlection Yes ViewChange Advanced Options No Sixnet Wireless P aii 4645 LaGuardia Drive St Louis MO 63134 Model Number Services Advanced Toll Free 800 439 7781 Fax 314 426 0007 Weh www jbmelecironics com WWww spmeLcom Copyright 2010 Sixnet LLC If the identity of the air card is acquired by the firmware these fields will be populated and no further action is required NOTE In some instances the inserted air card will be recognized but display a different carrier This is simply a matter of multiple carriers using the same model and make of air card GSM type air cards Most GSM type air cards require the use of a username password and APN to authenticate to the carrier network e Click on the Configuration menu item and the following window will appear NU Sixnet a red lpn business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Cellular Connection Currenty instalied Modem No modem detected Enable Interface Select Cellular Carrier Enter User Name Enter Password Confirm Password Select APN Context Enter APN SOCGe en Siera Wireless Aircard 875 Enable Modem Auto Detection View Change Advanced Options Sixnet Wireless Toll Free 800 4
7. amp Search Folders EN fay Folder Sync Address Network and Internet Connections Network and Internet Connections See Also My Network Places g Printers and Other Pick a task Hardware Q Remote Desktop oe z AESA 2 et up or change your Internet connection Be Phone and Modem Options a E a Create a connection to the network at your workplace Troubleshooters Set up or change your home or small office network Home or Small Office Set up a wireless network for a home or small office a Networking a k A Internet Explorer B Change Windows Firewall settings 2 Network Diagnostics or pick a Control Panel icon n Internet Options a Network Connections Connects to other computers networks and the Inter A Network Setup Wizard gt Windows Firewall Wireless Network Setup Wizard Vista Windows 7 GS Control Panel Network and Internet z 4 Search p Control Panel Home A A Network and Sharing Center a View network status and tasks Connect to a network View network computers and devices Add a device to the network Set up file sharing System and Maintenance Security Network and Internet panies sae FA Internet Options Hardware and Sound Change your homepage Manage browser add ons Delete browsing history and cookies Programs Offline Files Encrypt your offline files Manage disk space used by your offline files User Accounts and Family Saf
8. e Click on the Advanced gt GwInx gt Gwlnx Status menu item and the following window will appear Status Admin Networking Services Advanced _ Gwinx Running Status oO eO yyg a Gwinx Is Running PID amp CPU HEH Was R Y SCAT START 195290 682 0 5 3 06240 2204 7 al 15 26 106 49 _ owlox unit zml h otal ee eee eee Hone Selected Toll Free 300 489 7731 Fax 314 4276 0007 Sixnet Wireless z Web www sixnet com 4645 LaGuardia Dri A 6 aGuardia Drive St Louis MO 63134 Sixn eC t Model Number Copyright 7012 Sixnet LLC Send Email to Support on FT e Click on the Restart button and the following pop up window will appear Sixnet Inc A Red Lion Business SONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual successfully Restated Selected Gwinkx Process e Click on the OK button to acknowledge the content 3 6 6 9 GWLNX Logfile The Gwlnx Logfile menu item allows you to view the logfile generated by Gwlnx at startup which provides the state of each port controller defined in the Gwlnx configuration file and logs the Send Receive traffics for each configured port controller e Click on the Advanced gt GwInx gt Gwinx Logfile menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL
9. e Click on the Advanced gt Gwlinx gt Connect Table Configuration menu item and the following window will appear Status Admin Networking Services Advanced _ connect Table Configuration O OZ O Generic Sea ener DTMF Label AT Command Description AT Command Mode Sec Dial Mest Cancel Save Apply _ Toll Free 300 439 7731 Fax 314 426 0007 Sixnet Wireless ae Web www socnet com 4645 LaGuardia Drive T a a F st Louis MO 62134 Send Email to Support 25 Mail Model Number Copyright 2012 Sixnet LLC Generic Please use the recommended setting unless directed to change by Technical Support personnel a red lion business Sixnet Inc A Red Lion Business SONNE O R CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Recommended Setting No File Mode Please use the recommended setting unless directed to change by Technical Support personnel Recommended Setting DTMF e Click on the Add button and the following pop up window will appear Add Connect Table Configs Label Required rd ee eect Not Configured ine ee eee ANSWER rent w Reguired P Message Mode E LN JE a Eu Timer Data Mode Spoof ENG No Rx Before Tx Disable Ack Pass Through Ack No No f l No l No fel Se Enter Address i Required P M
10. e Click on the Status menu item and the following window will appear Status Networking Services Advanced IPSEC Tunnel Status No status available BB Always scroll display to end Sixnet Wireless P ai Toll Free 800 489 7781 tormariy ibm Electro Fax 314 426 0007 4645 LaGuardia Drive Web www Jbmelectronmcs com St Louis MO 63134 Www spaet com Model Number Copyright 2010 Sixnet LLC e Click on the Refresh button to rerun the status program at anytime This is helpful when attempting to troubleshoot a VPN connection NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Hon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 5 Services Tab The Services Tab is where you can configure the various service offerings of the Sixnet router These services include DHCP Server DHCP Relay Dynamic DNS SixView Manager GPS Server SSH Server SSL Client Server System Logging TELNET Server Ping Alive SNMP Agent and Modbus Services 3 5 1 DHCP Services Used to configure one of the internal Ethernet interfaces to be a DHCP server and hand out IP Addresses to systems connected to the Sixnet router
11. model number Copyright 2012 Sixnet Inc e Click on the Add button and the following pop up window will appear Edit ModBus Serial Table Device Name Baud rate Data bits ai Parity None Flow control None Stop bits i l meee Modbus Master ASCII Float Word Order Long Word Order Law l Enable Daniel Mode No TENETE es be ee ETETETT T Cancel OK Device Name Name of the serial device Baud rate Baud rate for serial device Supported baud rates are 300 600 1200 2400 9600 19200 and 38400 Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Data bits Number of data bits Supported data bits are 7 and 8 Parity Parity for serial device Supported parities are none even odd mark and odd Flow control Flow control for serial device Supported flow controls are none hardware xon xoff half duplex full duplex Stop bits Stop bits for serial device Supported stop bits are 1 and 2 Protocol Protocol being used on serial device Supported protocols are modbusMasterAscii modbusMasterRtu modbusSlaveAscii modbusSlaveRtu modbusMasterRtuFwd and modbusMasterAsciiFwd Float Word Order Controls the swapping of words within floats Ignored if using Daniel mode This is needed for configuring the serial slave application Supported or
12. 314 426 000 Web www jbmelectronmcs com WWww sixnet com Sixnet Wireless foe marty jibe Fie Pii 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC j Configure Advanced SSH Parameters Select Yes to configure advanced options for the SSH Server Listening IP Address For SSH Specifies the local IP Address on which the SSH server will accept connections NOTE Specifying a value of 0 0 0 0 allows the SSH server to accept connections on any interface Firewall rules must be present however to allow SSH connection on untrusted interfaces Listening IP Port For SSH Specifies the local IP port on which the SSH server will accept connections sS a red lion business Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual NOTE Specifying a value other than 22 will require proper firewall rules in order to allow connections to the given port SSH Protocol Version Specifies the protocol version for SSH Server to use NOTE Security flaws have been found in SSH protocol version 1 For that reason we recommend using protocol version 2 where possible Login Grace Time in seconds Specifies the amount of time in seconds after which the SSH server will disconnect if the user has not successfully logged in Recommended value is 30 Maximum Concurrent Connectio
13. 800 489 7 781 Sinet Wireless Fax 314 476 0007 4645 LaGuardia Dri a gt Web ixnet OF asUardia Unve SD WWW SAMEL com St Louis MO 63134 Si ale f Send Email to Support gt en Mal model_number Copyright 2012 Sixnet Inc Activity Log Level This controls the logging level for SSL Connection activity Recommended setting is Summary for a production and Full for test environment Wait for Connection sec Time in seconds allowed after sending SYN packets to wait for SYN ACK Default is 20 Idle Timeout min Time in minutes allowed for no traffic over an SSL connection before closing down the link Default is 720 Certificate A server certificate must be provided This will be used to encrypt communication with all clients The certificates must be in PEM format with an unencrypted key not password protected when generated Self signed certificates are highly recommended Use Admin Certificate Manager to install update certs Advance Setup Select Yes to modify advanced SSL options The display will expand to reveal the advance setup fields Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced SSL Server Sob Server Stopped Seca Yes Activity Log Level Summary Wait for Connection
14. Firmware Update menu item allows you to upgrade the firmware of the Sixnet router to the latest version to take advantage of advanced features e Click on the Firmware Update menu item and the following window will appear Status Networking Services Advanced Firmware Update Preserve current configuration ml Select Firmware image File Browse_ Sixnet Wireless Toll Free 800 489 7781 for marty jom Electronics Fax 314 426 0007 16 45 LaGuardia Drive Web wwwJjbmelectronics com St Louis MO 63134 wWww sbonet com Model Number Copyright 2010 Sixnet LLC To upgrade the firmware of the Sixnet router e Check the Preserve Current Configuration box to cause the device to save its current configuration and restore it after the firmware image is installed e Select the firmware image file type from the drop down list Note For SN BT model devices you need to select the Boot File System type and Browse to open boot file image first and click on Upload button for uploading the boot file Then once this step is completed select Root File System type and Browse to open root file image and click on Upload button for uploading the root file For D series model devices such as R3100 R3300 R1100 etc you need to select Bin File System type and Browse to open bin file image and click on Upload button for uploading the bin file e Click on the
15. IP Destinations CLI Status Signal Strength No Service Gwinx Status Gwinx Logfile Transniff Filter Toll Free 800 489 7761 Fax 314 426 0007 Web www sixnet com Send Email to Support oo Mail Copyright 2012 Sixnet LLC NOTE Please refer to the third party device user manual and or technical support to determine what type of connection is required to connect with the Sixnet router from the RS232 serial port NU Sixnet Inc A Red Lion Business a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 877 8346 IndustrialPro Series Router User Manual Click on the Gwlnx7 gt Serial IP menu item and the following window will appear Status Admin Networking Services Advanced Serial IP Interface Enable Seria IP Enter Configuration Description OO 4 Line Speed Independent Activation com x Bio oe o RAE Word Length Parity Bf Th r i Stop Bit Connect Mode fb Ignore DTR s 3 Connection Type lt fh Use Timer Only 7 7 7 7 7 DTR Dial Inter Character Timeout ms Maximum Buffer Size Enable Hardware Flow Control Number Of Missed Polls Allowed H q Ee Socket Type UDP are ae eee 0 0 0 Reguired rd Pee Prot Client IP Port Reguired _ Cancel Save Apply _ Toll Free 800 489 7 781 Sixnet Wireless P Fax 314 426 0007 4645 LaGuardia Dr
16. Sixnet S o a req lon business RAM 6000 Series Router IndustrialPro Series Router and IP V R Series Router Software User Guide Version 1 09 Software Version 3 12 October 16 2012 RAMG6000 and IndustrialPro Series Router User Manual Table of Contents 1 ACCESSING THE GRAPHICAL MANAGEMENT INTERFACE ccccccccccccccsscccccceeseecccceeseccsceeeecseeeueecssssueecsesuueeessseuueeeseees 4 LI SCONINBET PC TOSIXNET ROUTER eerie bias ieinucdedoanseaniemsuasis tadudins lgosudieteonses a aai tobnestekeaovtehicmens 4 La OUP PE MP Ip RSS aac ce seas atte nad aecsceane sien sane cauateta vate snaeaafevenenees E sas seeuasaeadesareacetesdeeaandeusdcanateaamacsyesceevccaleaeeacn cannes 5 Boa OPa oe O16 O a2 1 re OM eT OTE MOONEE TEN ROSEN een NNTE Poem en VAE ey ene em es anTT Sen aee Renee ear TN eo eR eee ere ree 5 REDD ACCS NAWO ana IEIET CLI S dai a EE eds cosa ten civ cab ic eg eae EER nay dank Se 7 DDD TCOOSS IN COW OTIC ON COLIN ELLIS ecard ltt crn ssc tected sc sess ten divans cep ele EE ena dank See 9 koa Access Loco Area Connec Olosan anseo ae EE Neon TE CTR E Trae A Oe T 10 ke OCI TO OVS aces chee a E A E E E cere aa Enea Ta aL oma Seah etenes Il Labo Access Iien Toco FPO CCS aroro EAE ad ce nS se aw ves moet ate Rp ase ne 12 Lo PCC SS SONS EVV Vo cscs se TE eestor TEETE EE ec smc A E AE EAE on nasnesebacacee os 16 To CT ROUT LOT SUCOS eri r e casinos E cae can Sas aon GT IS 1 3 2 SSH TELNET Serial RS
17. Upload button You will see the following warning pop up The page at http lt IP Address 10000 says This action will cause the device to be be completely wiped clean and have a new system image installed which will result in the entire device configuration to be reset to its factory defaults This includes communication interface settings Your connection to the device will be terminated If the device is installed on a remote network the new default settings could render the device incommunicable Are you sure you want to proceed Gre ED N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to acknowledge the warning NOTE This procedure could take anywhere from 6 to 10 minutes to complete WARNING It is extremely important that the power to the unit is not interrupted as this could cause the unit to become corrupt and require shipment back to the factory to correct NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red If9n business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 3 5 Gather Configs The Gather Configs menu item allows you to zip up the configuration files of the Sixnet router in order to send
18. a O Add Toll Free 800 489 7781 Fax 314 426 0007 Sixnet Wireless z Web www sixnet com 4645 LaGuardia Drive St is T z S ec chat ate Send Email to Support BT 6621 HSPA Copyright 2012 Sixnet Inc e Click on the Add button to configure the Forwarding and the following pop up window will appear Add ModBus Forwarding Station Number i Forward Station Number EEH TCPIIP Address Po OK Station Number Station number to be forwarded Valid values are 1 247 Forward Station Number If supplied replaces the station number in the request with this value Valid values are 1 247 Type Select the forwarding method Valid options are TCP UDP and Serial Address Valid IP address if the selected type is TCP or UDP or the Serial device name if the selected type is Serial Port IP port number to forward the request to on the remote station The default port is 502 e Click on the OK button to populate the Forwarding Table screen If more than one forward is needed click and repeat the Add button Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the Save button to save the Forwarding configuration in the modbus xml file Serial Status Admin Networking Advanced SN Industrial Pro model_nu
19. red Mlle iiciocs 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced ModBus Stations Enable Modbus Interface Sixnet Wireless Ke A Toll Free 800 489 7781 4645 LaGuardia Drive 2 3 Mi Fax 314 426 0007 St Louis MO 63134 A i Web www sixnet com Copyright 2010 Sixnet LLC e Select Yes to Enable Modbus Interface option and the following window will appear Status Admin Networking Services Advanced ModBus Stations Local Station Station Name P Required Station Number iz Required Local Port Aea Remote Stations Table Properties Station Name Station Number Remote IP Address Remote IP Port Message 10 Transfers Forwards Serials Display Config Files _ _ Cancel Save s Toll Free 800 489 7781 Sixnet Wireless l Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com s St Louis MO 63134 ixn e t BT 6821 HSPA Copyright 2012 Sixnet Inc Send Email to Support gt gt a Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Station Name Enter the name of the local station The station name must be less than or equal to 32 characters Station Number Enter the local station number The station number mus
20. 10000 says eS DHCP Server settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says eS DHCP Server settings applied e Click on the OK button to acknowledge the content Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual DHCP Relay Click on DHCP Relay and the following screen will appear Status Admin Networking Services Advanced DHCP Relay Enable DHCP Rday Seq LAE No Interface Table Delete Remote Servers R emote Server Delete Toll Free 800 489 7781 Sixnet Wireless l Fax 314 426 0007 4645 LaGuardia Drive Web www sinet com St Louis MO 63134 Send Email to Support model number Copyright 2012 Sixnet Inc DHCP Relay will enable a service that will allow you to connect a local interface with a remote DHCP Server Enable DHCP Relay Select Yes to enable the DHCP Relay or No to disable it The service will start once the Apply button is clicked If the Save button is clicked the service will not be started until after the device is rebooted and then only if the Start at boot time option has been also set to Yes Start at Boot Select Yes to enable the DHCP Relay at boot tim
21. 11 03 _ khubd Ss 11 03 init Ss 11 03 sbin gpio_button Ss 11 03 bin lightbar 33s 11 03 syslogd 3 m 0 s 256 11 03 klogd c 1 11 03 xinetd stayalive reus 11 03 bin boa tc jbm jb 20 28 _ gau 20 28 _ ps auxut 11 03 sbhin dnsmasq C etc d 11 03 f bin crond 11 03 bin jbminic 11 03 _ bin wm_vatch 11 03 _ sbin gpsc ooooocooooocoooceocococso eo Qqg 0a 0qo0qcq0doqooqocoqooqooqocoooCc oe ee oe Y Y y ee YY y ee y Y y ee ee Yy yy y Y ee ee ee ee ee eS eS ee OO EE EE EE EE A A A o Qa o ower nods ow Q d o J wn P9 ww ex yr an oo Ww wv moooo0ocdoo CPU 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 go Qgo0 e0qg 0g 0 0c Qo 0 eo 00 0 0 oao0oocoqacoco oncoo oo Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electronic Fax 314 4276 0007 4645 LaGuardia Drive Web www jJbmelectr onics com St Louts MO 63134 Www spanet corm Model Number Copyright 2010 Sixnet LLC NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 2 8 System Services The System Services menu item will display the status of the services available on the Sixnet router Status Admin Networking Services Adva
22. 93 ECIO 14 0 Unknown 09 27 CSQ 93 ECIO 10 0 4436 Oo 27 C50 102 ECIO AN 462 097 27 ie C50 102 ECIO 3 HAN 462 097 27 16 53 CSQ 102 ECIO P AN 462 09 27 i CSQ 102 ECIO 462 i Toll Free 800 489 7 781 sinet Wireless Fax 314 426 0007 4645 LaGuardia Drive Web www siknet com St Louis MO 63134 Send Email to Support model_number Copyright 2012 Sixnet Inc NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 2 12 Update History The Update History menu item will display a listing of any software updates that have been loaded onto the Sixnet router Status Admin Networking Services Advanced Home Aro Cache i Installed Firmware Version Feature Codes SSS ES SSS Firmware Version Number Firewall Rules Device Serial Number 5erial Murmber System Processes a Fhysical Interface Status System Information Connection State IP Address Link Status Lp 192 168 0 1 Lp Update History Up 192 168 1 1 Up vena ilcnace Activation Connection IP Address Signal Strength pppo ed Enabled T2 101 201 31 EVDO REV A ST eee Disabled Fd Sixnet Wireless E Toll Free 800 489 7781 formerly jom Electronics aT Fax 314 426 0007 4645 LaGuardia Drive a L S af ba Web www jbmelectronics com St Louis MO
23. A OOOO OO m S m S m S m S m S Oooo aa S m S m DO m D m G m G m G m S m S m S a S ma S ma S a G OO m S mn S mn A m S mn S m S a S m G a S m S m S a oOo m S mn S mn A m S mn S m S a S m G m S m S ma S m oo mn S m S m D m S m S m S m S m S aa S m S ma S m SO m G m O a G m G mn S mn S mn S m S m S m S a S m S m S a S m S m D m G m O m G m eo Sixnet Wireless Toll Free 800 489 7781 formerly jom Electronics e Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC You can scroll through the list of rules to review the entire IPTABLES listing This is valuable information allows you to track down what is being allowed and what is being denied access to and through the Sixnet router N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 2 4 Interface Information The Interface Information menu item is sub sectioned into three sections Summary Details and Multicast Status Admin Networking Services Advanced Home Aro Cache Installed Firmware Version Feature Codes i Firmware Version Number Firewall Rules Summary Jevice Serial Number Details Serial Number Multicast system Processes System Semices Physical Interface Status sical Interface Status oyste
24. Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Filter Rules Firewall The Filter Rules menu item allows you to configure routes from a small range of IP Addresses or all IP Addresses through one or more interfaces to a designated IP Address located behind the Sixnet router e Click on the Filter Rules menu item and the following window will appear Status Networking Services Advanced Firewall Filter Rules In Interface Source Whitelist Out Interface Destination Sixnet Wireless Toll Free 800 489 7781 formerly jom Electronic Fax 314 426 0007 4645 LaGuardia Drive f Web www Jbmelecironics com St Louis MO 63134 WWW SDmet com Model Number Copyright 2010 Sixnet LLC To add a filter rule e Click on the Add button and the following pop up window will appear Add Filter Rule ipewe pie All Untrusted Source subnets via Whitelist aTa piee All Untrusted Destination Address Subnet fF ss Required OK Inbound Interface Click on the pull down menu to choose an interface associated with the Source Address Subne
25. Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual roaming INTEGER 0 1 O currently not roaming 1 currently roaming nen E INTEGER Connecting Dormant Connected Disconnected Error Calllncoming Current Modem State speedPref STRING Automatic CDMAonly EVDOonly What speed preference the modem is currently set to lock to roamPref STRING HomeOnly HomePreferred AUTO RoamOnly Aonly Bonly AutoA AutoB unknown The current setting for the modem s network roaming preference STRING The device name as presented by the operating system STRING a a interface name if known as presented by the operating system txCount INTEGER Current Wireless PPP TX byte count since connection has been up updated every 30 mins rxCount INTEGER Current Wireless PPP RX byte count since connection has been up updated every 30 mins STRING The state of the GSM connection idle ready standby STRING The signal level seen at the receiver measured in dBm servingCell STRING The Current Cell on which the device is camped STRING rrcState Radio Resources Control State also called Packet Data Transfer state idle CELL_DCH CELL_FACH CELL_PCH and URA_PCH STRING Indicates which GSM channel or band of frequencies the device is currently connected to STRING Pulls CELLMODEM_PS_ STATE from var log wireless cardstats STRING Pulls CELLMODEM_MODE from var log wireless cardstats g
26. Baud Rate 110 115 200 bps Console Port Interface One Female DB 9 RS 232C DCE Mbps 10 100BaseT Ethernet Ports Interface Female RJ 45 connectors RS 232 Port Baud Rate 110 115 200 bps Async Interface Optional One Male DB 9 RS 232C DTE Operating System Linux 2 6 Kernel Console Port CLI Access through async connection Management IP Protocol SNMP HTTP S Telnet SSH Power 12V DC External 120 VAC 60Hz or 120 240 VAC 50 60Hz Size 7 75 W x 1 5 Hx 6 75 L Physical Weight 2 pounds Processor PowerPC RISC Memory 64 MB RAM 32MB Flash Warranty 1 Year Parts and Labor Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 5 Software Licensing Terms and Conditions Software supplied with each Sixnet product remains the exclusive property of Sixnet Sixnet grants with each unit a perpetual license to use this software with the express limitation that the software may not be copied or used in any other product for any purpose It may not be reverse engineered or used for any other purpose other than in and with the computer hardware sold by Sixnet FCC Compliance Statement This equipment has been tested and found to comply with
27. Hardware maintenance and repair is available on a return to factory basis 2 Configuration assistance is included for the first 60 days after the initial contact to Sixnet Technical support After this initial period configuration assistance will continue to be available on a chargeable basis 3 Software support does not provide for custom code Custom changes are available as a chargeable option 4 The warranty only covers items with a serial number Cables and adapters are not covered Extended Warranty Program Sixnet offers an extended warranty for the router This program extends the original warranty on a yearly basis In addition to extending the original warranty the emergency replacement program is included for the cost of freight only The extension must be purchased before the original warranty expires Please contact Sixnet for further information Except for the express warranty set forth herein Sixnet grants no warranties either express or implied of merchantability and fitness The stated express warranty is in lieu of all liabilities or obligations of Sixnet for damages including but not limited to consequential damages occurring out of or in connection with the delivery use or performance of Sixnet products Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 7
28. NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Provisioning for Static Vision alternate If you are using Static Vision alternate provisioning there are two more required fields than there are for Vision Static only provisioning The Set PPP Error threshold field and Set Vision timeout field should automatically be defaulted to the numbers below Set PPP Error threshold 10 Set Vision timeout 1440 When all of your information is correct click Apply Provisioning for Datalink only or Datalink Vision alternate If you are provisioning for Datalink only or Datalink Vision alternate enter the following information Enter the SPC Unlock code provided by your cellular carrier at time of activation The Mobile IP mode should always be set to Mobile IP preferred You will set Sync system time to cellular network time to Yes Enter the ESN which can be found in the upper window next to Detected ESN Enter the MDN provided by your cellular carrier Enter the MSID provided by your cellular carrier Enter the NAI User Name provided by your cellular carrier Enter the AAA Password provided by your cellular carrier HA Password provided by your cellular carrier Home IP Address provided by your cellular carrier Primary HA IP Address provided by your cellular carrier Secondary HA IP Address provided by your cellular carrier When all of your information is correctly
29. When this link is intended as a Primary network connection e On Demand When this link is intended as a Fallback network connection Dial on Demand DoD Idle Timeout Enter the number of seconds the connection may be allowed to remain idle no data transmitted or received before closing the connection This will allow a DoD connection to automatically reset once idle so that any network usage is limited Recommended setting is 300 seconds 5 minutes This is useful for an environment where constant usage of the POTS line is not desired Use Default Route e Yes When this link is intended as a Primary network connection e No When this link is intended as a Fallback network connection Advance Setup Select Yes to modify modem control the modem speaker and enter modem initialization string The display will expand to reveal the Advance Setup options Advance Setup les l Madmum Receive idle Time nso OTEA ves AEEA ves Modem Speaker On No Enter Custom AT commana Sixnet Wireless Toll Free 800 489 7781 foemerty jbm Blectrorics a Fax 314 426 0007 4645 LaGuar dia Di ive Web www jbmetectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sixnet LLC Maximum Receive Idle Time Enter the number of seconds the connection may be allowed to remain Idle or Unresponsive no data received before closing the connection If packets are leaving the interface but no return
30. ee eile nE Disabled Toll Free 800 489 7 781 Sixnet Wireless P a Fax 314 426 0007 4645 LaGuardia Drive A a ee eS Web www sinet com St Louis MO 63134 wWIXNE t Send Email to Support 52nd 5 model number Copyright 2012 Sixnet Inc NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual From the navigationmenu select Services gt I O Settings gt Test I O and you will see this screen Status Admin Networking Services Advanced Access to Test_IO Page Display Test_IO Page Click Test_IO in Red to Display The Page Toll Free 800 489 7 781 Sixnet Wireless F aa Fax 314 426 0007 4645 LaGuardia Drive Web www scnet com St Louis MO 63134 Send Email to Support model number Copyright 2012 Sixnet Inc Clicking on the Test I O Link in RED will take you to the Test I O interface below Firefox w S Sixnet Administration Utility x 192 168 0 1 10000 We v e 8 Googie Prt B B Home Scan Rate 5 Show Messages l Sixnet Select Type Start Address 0 Register Count 8 Columns 8 Add To testlO ared hor business The Test I O interface has been kept simple to make managing the test I O process easier and keep the screen less cluttered and easier to look at and quickly locate your test values Home This link will take you back to the main GAU Menu
31. i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced SOFT 5 0978u9 99 191137ug 59415142 0u 190715151109 1S5F15 836 9un9 1SOTLSRSOTud SOFT 5858109 0909 160 92u 594 160992u3 00ta l4To6ug 59t3203EluJ Toate 20947Tud tote SSET Tus tSoTe 9 S7E2u9 554 465159u9 39 0 906903 55 911704u9 19579117899 55 977702u9 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 01 0001 Gelnx is Running DLE TITMEIO TITMEIO TITMEIO TITBEIO TITHEIO TITHEIO TITMEIO TITBMEIO TITHEIO TITHEIGO TITMEIO TITBEIO Ignoring DIR status Ho Baud Rate Owitching Set Modem Init Ho At Command Cont dtate Change eITHITi State Change eINIT2 In DtrDial Mode Pretend Dial Comm State Change s sJENDCONHECLT dtart Connect Delay if it is not State Change MODEMCONNECTED1I dtate Change eMODEMCONNECTED Wait To Raise DOD Fignal Upon Remo State Change eMODEMCONNHECTEDS Raising DCD Because Remote Device TITIO CONHECIFHYJ Allowing Connect TIYMEIG TIYMEIC State Change eRAIT 400 dtate Change eMODEMCONNECTED4 EOR Device connecting gt Wait to Verify EOR Ho unexpected msg in queue EOR Device connecting gt Fully CONNECTED _Gwinx Log O O aaa rt Always
32. ntemet Protocol The default Wide area network protocol that provides communication Install Uninstall across diverse interconnected networks I lescnpti ion Transmission Control Protocol Intemet Protocol The default C Show icon in notification area when connected nile ceca neimak puinc thal pries communication Notify me when thi connection has limited or no connectiwity across diverse interconnected networks Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual 1 2 6 Access Internet Protocol Properties e Click on the Internet Protocol item to highlight o XP Internet Protocol TCP IP o Vista Windows 7 Internet Protocol Version 4 TCP IPv4 e Click on the Properties button The display should look similar to the following XP Internet Protocol TCP IP Properties General Alternate Configuration Tou can get F settings assigned automatically if your network supports Vista Wi ndows 7 this capability Othenwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically O Use the following IF address IP address You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator Subnet
33. o eth0 Used to configure IP Address Network for Ethernet 0 interface o eth1 Used to configure IP Address Network for Ethernet 1 interface o usb Used to configure IP Address Network for Usb interface If available on the unit e Firewall organized into eight 8 sub sections o General Settings Used to configure common access services to the Sixnet router and configure how the interfaces are interpreted o DMZ Host Rules Used to configure rules to route through a DMZ o Filter Rules Used to strictly define routes between interfaces o Host Redirect Rules Used to redirect specific ports to alternate ports through the Sixnet router o Masquerade Rules Used to define networks to be considered as internal entities o NAT Rules Used to define rules for Network Address Translation between interfaces on the Sixnet router o Service Access Rules Used to define specific port port range allowed into the Sixnet router through the firewall o Subnet Blacklist Rules Used to define specific networks that are strictly denied access to the Sixnet router o Subnet Whitelist Rules Used to define specific networks that are allowed access to the Sixnet router e PPP Dial Backup Used to configure the capability of dialing out to an ISP for connectivity on units containing the 56K modem e PPP over Ethernet Used to configure to use the connection of a ADSL setup e Static Routes Used to configure static routes for the Sixnet router e TCP Keep Alives Used to con
34. sec 20 idla Timeout min Advance Setup vesz Bind Interface for accepting SSL Connections Any Bind imerface for outgoing TCP Connections jAny ee RC4 HDSsRC4 SHA ALL ADH aNULL eNULL LOW EXP SSLv2 RC4 RSA HIGH MEDIUM Keep Alive behavior None Label SSL Listening IP SSL Listening Port TCP Destination IP TCP Destination Port Sixnet Wireless Toll Free 800 489 7781 orreeriy jom Electronios Fax 314 476 0007 1645 LaGuardia Drive Ss 4 Web www jbmetectronics com St Louis MO 63134 wes www sinet com Model Number Copyright 2010 Sixnet LLC Bind Interface for accepting TCP Connections This will restrict the unencrypted listening socket to allow connections coming into the specified interface only Recommended setting is Any Bind Interface for outgoing SSL Connections This will restrict the encrypted socket to initiate connections out the specified interface only Specifying an interface here may conflict with policy routing however it may be required in a GRE VPN or other tunneled environment Please consult with a network architect for additional assistance Recommended setting is Any Ciphers This field is a list of openssl ciphers supported Please consult support staff before attempting to change Reference Google openssl cipher list for more information Recommended setting is RC4 MD5 RC4 SHA SSLv3 NU Sixnet Inc A Red Lion Business CON
35. tnprisvar 2046 1 tmptistmp 40960 40 26 6 Var 8 O tmp Memory Usage total used free buffers cached Mem 126232 23408 102824 0 14104 buffers cache 9304 116928 Swap 0 g 0 Sixnet Wireless loll Free 800 489 7781 Sar mnarly ibm Electrory Fax 314 426 0007 4645 LaGuardia Drive l F Web www jbmetectronics com St Louis MO 63134 n www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 2 10 Syslog The Syslog menu item will display the current entries into the syslog of the Sixnet router Status Admin Networking Services Advanced Horne Aro Cache J Installed Firmware Version Feature Codes M Firmware Version Mumber Firewall Rules Device Serial Number Serial Number system Processes Tense miee Physical Interface Status system Information Connection State IP Address Link Status Up 192 168 0 1 Up Update History Up 199 168 14 Up cewar menace Activation Connection IP Address Signal Strength pppo 5 ed Enabled ae EVDO REV A Slee ele Disabled P Sixnet Wireless E Toll Free 800 489 7781 formerly jom Electronics aih lead Fax 314 426 0007 4645 LaGuardia Drive Fwri iar Web www jbmelectronics com St Louis MO 63134 ee te Tr 4 WWW Ssixnet com Model Number Copyright
36. 10000 says Operation Succeeded e Click on the OK button to acknowledge the content The package has been successfully uploaded and installed NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 3 9 Reboot The Reboot menu item allows you to remotely reboot the device if necessary e Click on the Reboot menu item and the following window will appear Status Networking Services Advanced Reboot System Sixnet Wireless for mart mm Electronica 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7781 Fax 314 426 0007 Web www itunelectronics com Www spanetLcom Model Number Copyright 2010 Sixnet LLC e Click on the Reboot button e The following warning pop up window will appear The page at http lt IP Address gt 10000 says This action will cause the device to reboot Your connection will be lost Incomplete or incorrect network settings could render the device incommunicable Are you sure you want to proceed Caneel XD e Click on the OK button the reboot the Sixnet router remotely NOTE It may take 3 to 5 minutes for the Sixnet router to fully reboot Any connection attempt should only be attempted after a sufficient amount of time has passed ot Sixnet Sixnet Inc A Red
37. 2010 Sixnet LLC NU a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the Syslog menu item and the following window will appear This screen is configurable to allow searches using a string filter Enter a filter string in the space provided only lines containing the filter value s will be displayed via a grep style filter mechanism Note the filter value is case sensitive Status Networking Services Advanced System Log Using filter kernel 13 20 54 31 Kernel loop module loaded 13 20 54 31 kernel Intel R PRO 1000 Network Driver version 7 3 20 k2 NAPI 13 20 84 31 kernel Copyright ic 1999 2006 Intel Corporation 13 20 54 31 Kernel Gianfar MII Bus probed 20 54 31 kernel fsl giantar fal gianfar 0 enabling Lossiess Flow Control 20 84 31 kernel ethO Gianfar Ethernet Controller Version 1 3 skbr 00 60 20 54 31 Kernel GFAR SKB Handler initialized at CPUSO max 32 20 54 31 Kernel ethO ATU 1500 frame size 1526 truesizce 1816 20 54 31 kernel thO Running with NAPI enabled 20 54 31 Kernel ethO 64 64 RX TX BD ring size 20 54 31 kernel fal giantar fsl gianfar 1 enabling Lossiess Flow Control 20 54 31 kernel thi Gianfar Ethernet Controller Version 1 3 skbr 00 60 20 54 31 kernel GFAR SKB Handler initialized at CPUSO max 32 20 54 31 kernel ethli NTU 1500 frame size 1526 truesize 1
38. 63134 ea eR Er G WWW sixnet com Model Number Copyright 2010 Sixnet LLC a red ier busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 2 13 Diagnostic Tools The Diagnostic Tools menu item is sub sectioned into Ping Socket Test Soeed Test and Traceroute These are useful in troubleshooting connectivity of the Sixnet router to the Internet or the network the router is connected to Admin Networking Services Advanced Status Aro Cache Installed Firmware Version Feature Codes Firmware wersion Number Firewall Rules Device Serial Number Serial Number Physical Interface Status Link Status IP Address 192 168 111 1 Up 192 168 10 195 Lp System Services 7 Connection State System Information Lp E D Syslog Update History Connection IP Address Signal Strength None ean Socket Test Disabled gt Ping 3 Unavailable N A pppo at Speed Test Traceroute E Sixnet Wireless al Toll Free 800 489 7 761 4645 LaGuardia Drive ee Fax 314 4276 0007 e Si aes Web wyy siznet com St Louis MO 63134 Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business COI ONITOR Ci 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 151 8 877 8346 a red lion business IndustrialPro Series Router User Manual The Ping menu item allows you to input an address either as an IP Address or
39. 8346 IndustrialPro Series Router User Manual 3 6 4 Virtual Routing Redundancy Protocol VRRP VRRP is supported in Sixnet Routers in the IndustrialPro and EnterprisePro series To configure VRRP select the option from the Advanced menu The VRRP menu item allows you to configure the capability of providing redundancy capabilities to each other as well as other third party devices Admin Networking Services Installed Firmware Version Firmware Version Nurber Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address ethOd Up eth Up IP Address 72 101 201321 Cellular Interface Activation Connection Pppo ed Enabled atl eee Disabled sd Sixnet Wireless formerly jom Electronics 4645 LaGuardia Drive St Louis MO 63134 Model Number e Click onthe VRRP menu item and the following window will appear Status Networking Services VRRP Enable VRRP No Z Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Model Number NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 Advanced IF Fallback IP Transparency Qut of Band Mat VRRP Link Status E H Up Signal Strength EYDO REW A Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com WWW sixnet com Copyright 2010 Sixnet LLC Advanced Toll Free 800 489 7
40. DHCP Services are divided into DHCP Server and DHCP Relay subsections Status Admin Networking Services Advanced unit_name Administrati DHCP Server Dynamic DNS Installed Firmware Vers SNProxy Settings DHCP Relay firmware revision i SixView Manager GPS Settings Device Serial Numbe SSH Server serial number System Logging Physical Interface Stat rane rver Ethernet Interface Connection State IP ik Status usb Up 192 Ping Alive wn etho ee 192 SNMP Agent Cellular Interface Activation Connection IP Add N A Not Reg Disabled N A Cellular Uptime N A SAGOR Eal Disabled X P Toll Free 800 489 7781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive a i be Web www sixnet com St Louis MO 63134 i Xi e f Send Email to Support Ma model_number Copyright 2012 Sixnet Inc Click on the DHCP Server menu item and the following window will appear Sixnet Inc A Red Lion Business CONNEC ONITOR COI NU red in vusiness 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced DHCP Server Settings Global Settings Enter Domain name Po 14400 Use Sixnet Standard DNS Settings Enter Default Lease time seconds Enter Maximum Lease time seconds Enter Minimum Lease time seconds DHCP Servers etho Enable DHCP for eth No Enable Default G teway for et
41. Demand e Click on the Apply button and the following pop up window will appear PPPoE settings saved and applied e Click on the OK button to acknowledge the content 3 4 7 Static Routes The Static Routes menu item allows you to configure a route to a network through an interface manually e Click on the Static Routes menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Static Routes Interface Any Type IP Address Subnet Netmask Gateway Metric Tl Add Sixnet Wireless Toll Free 800 489 7781 t bm Fax 314 476 0007 marly jbm Electro 4645 LaGuardia Drive Web www Jbinelectronics com St Louis MO 63134 WWww sponet corm Model Number Copyright 2010 Sixnet LLC To add a static route on the Sixnet router e Click on the Add button and the following pop up window will appear Add Static Route Interface eth Use as Any route No Select Route Type Host Enter Target IP Address Enter Metric Ta Interface Select the interface to which the route should apply by selecting one of the available established options Use as Any route Select whether or not this route should be used as an a
42. Disabled Sixnet Wireless i Toll Free 800 489 7781 formerly jbm Electronics Fax 314 426 0007 to amp 4645 LaGuardia Drive f Web www jbmelectronics com St Louis MO 63134 IX i e www sixnet com Model Number Copyright 2010 Sixnet LLC 3 4 1 Cellular Connection The Cellular Connection menu item is sub sectioned into Configuration and Provisioning This allows you to configure the cellular air card SIM on the Sixnet router NOTE The Sixnet router s firmware will recognize supported air cards and will use the appropriate drivers If the air card is on the GSM network and requires the use of a username password and APN then you will need to verify the information and input the data on the Configuration page NOTE The Provisioning page is currently only available for air cards supplied by Nortel Configuration The Configuration menu item allows you to make configuration changes to the air card SIM on the Sixnet router e Click on the Configuration menu item and the following window will appear Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Cellular Connection Currently installed Modem No modem detected Enable interface ves eee eee la Verizon F Enter User Name Enter Password Confirm Password
43. E p Connection Enabled IP Address Te LU m IP in IP Tunnels ink Status Configuration 192 168 1 1 status Signal Strength EVDO REV A Fi Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com WWW sixnet com Copyright 2010 Sixnet LLC e Click on the Configuration menu item and the following window will appear NU a red lion business Sixnet Inc A Red Lion Business CONNECT MONITOR CON 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 151 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced IPSEC Enable IPSEC No Sixnet Wireless Ee Toll Free 800 489 7781 for marty jbm Glectronic Fax 314 426 0007 4645 LaGuardia Drive f WebowwwJjbmelectronics com St Louis MO 63134 a i www sbaet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu at the Enable IPSEC field e Click on Yes and the display will expand to reveal the following screen Status Networking Services Advanced IPSEC Enable IPSEC Yes Enable NAT Traversal No Coordinate IPSec with Wireless PPP On SER IPSec Restart On Oise Tem PSecStop Coordinate IPSec with PPPOE On Bruit IPSec Restart on Remus Sec Stop Coordinate IPSec Dial up PPP On Bi IPSec Restart on Semin PSecStop IPSEC Tunnels _ Add Sixnet Wireless Toll Free 800 489 7781 formerty iben Electronics Fa
44. External Aircards from vendors other than Sierra Wireless and Novatel may need to be activated in a laptop first This does not apply to SIM based Aircards A list of supported external Aircards can be found at http sixnet com content aircard 86 cfm Embedded modules for CDMA Sprint Verizon should activate automatically over the air once they are powered on and connected to an antenna This of course is after you contact your carrier and have an account enabled and connected to the embedded module by providing the ESN MEID number from the module to your carrier This is how the carrier will tie your account to the internal Cellular Modem For some CDMA based 1xRTT internal modules and Sprint Data Link connections additional configuration must be set in the Provisioning screen detailed later Navigate through the GAU menus Networking gt Cellular Connection gt Configuration screen shown below Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual GSM based carriers such as AT amp T Bell Mobility and Telus will require a SIM card be inserted into the unit and an APN code to be entered to confirm you are the verified user of that SIM Be sure to only insert and remove the SIM card while the unit is powered off You can verify your cellular connectivity by viewing the Home Status p
45. Host Processing Server When using DIAL mode this field is not used Enter Port 1 This is a Client Primary Port address that GWLNX uses to connect to the Host Server Port For coordination with SSL Connections this field should match the TCP Listening Port configured in Services gt SSL Connections gt SSL Client to reach the specified remote SSL Host Server When using DIAL mode and Gwlnx is configured for Dynamic TCP Server Listener Port this field will specify the TCP Port to listen on Recommended Setting Recommended value for this mode is 1000 Enter Address 2 This is a Client First Alternative IP address that GWLNX uses to connect to the Host Server Not Required Enter Port 2 This is a Client First Alternative Port address that GWLNX uses to connect to the Host Server Port Not Required NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Enter Address 2 This is a Client Second Alternative IP address that GWLNX uses to connect to the Host Server Not Required Enter Port 2 This is a Client Second Alternative Port address that GWLNX uses to connect to the Host Server Port Not Required Host Message Format Following are the host message format in supported Message Mode Transparent Mode Unused Visa Mode This describes the format expected by
46. IP Address Signal Strength ppp Enabled T2 101 168 120 EVDO REY A Wid Sixnet Wireless E Toll Free 800 489 7781 formerly jom Electronics gh Bees Fax 314 426 000 4645 LaGuardia Drive Sh sae i i Web www jbmelectronics com St Louis MO 63134 i eke E r G Www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNEC ON NTROL 8 877 8346 a red ier busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 151 IndustrialPro Series Router User Manual 3 1 2 Status The Status Tab is where you will find information on the actual system The Status Tab is organized into twelve 12 sections e Arp Cache Shows connected network systems e Feature Codes Gives a list of the features running on this system e Firewall Rules Displays IPTABLES readout of system e Interface Information System Interface information o Summary Brief summary of the interface status o Details Detailed information on the interfaces o Multicast Displays the interface multicast information e Routing Information Routing information o Policy Routing Table Displays policies used for routing o Standard Routing Table Displays routing table information e Socket Statuses Active Internet Connections o TCP Only Internet connections with established connections o All Internet connections to include TCP UDP and Unix connections e System Processes Displays list of all running processes e System Serv
47. IndustrialPro Series Router User Manual 3 2 9 System Information The System Information menu item will display the current usage of the file system in both the directory size and the memory utilization Status Admin Networking Services Advanced Home Ar p Cache a Installed Firmware Version Feature Codes M Firmware Version Number Firewall Rules Device Serial Number Serial Number aystem Processes 5 ystem SeMices Physical Interface Status h S i c al nte fac e Statu S System Information Connection State IP Address Link Status Syslog Up 192 168 0 1 Up Update History Up 199 168 11 Up venuiaileace Activation Connection IP Address signal Strength ppp Sut ad Enabled f2 101 201 31 EVDO REV A Sencar Disabled Sixnet Wireless E Toll Free 800 489 7781 formerly jom Electronics a Fax 314 426 0007 4645 LaGuardia Drive k y p g t Web www jbmelectronics com St Louis MO 63134 are Wr WWW Sixnet com Model Number Copyright 2010 Sixnet LLC a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the System Information menu item and the following window will appear Status Networking Services Advanced System Information Filesystem Status Filesystem iK blocks Available Uses Mounted on f Gev root 24576 4996 50 dev mtdblockl 4096 3708 9 storacge dev mtdb lock2 3072 536 79 boot
48. Manual e Click on the OK button and the Sixnet router will reboot e Double check the unit when it comes back online to ensure the configs are as they should be Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Han busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 3 8 Package Installation The Package Installation menu item allows you to upload and install any patches that come from Sixnet Click on the Package Installation menu item and the following window will appear Status Networking Services Advanced Package Installation Select Package File BB View package installation history Sixnet Wireless Toll Free 800 489 7781 foe marily ib Electrorecs Fax 314 426 0007 4645 LaGuardia Drive Webowwwjbmetectr onics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Browse button and the File Explorer window will appear File Upload aga Look in Directory Patch Location gt x em B E lt Patchname gt zip My Recent Documents Desktop My Documents bis Conk File name lt Patchname gt zip My Network Files of type All Files v Cancel e Browse to the directory that the patch is located Click on the filename to highlight the file Note Be sure to use only genuine Sixnet provided packages in
49. NAT have private Internet addresses Status Admin Networking Services Advanced DNS Settings Instal n F irr General Settings PPP Dial Backup De PPP over Ethernet DM Host Rules Filter Rules Siae Rous Host Redirect Rules TCP Global Setings Phy Masquerade Rules NAT Rules Ethernet Interface Connection State zeen Rules ink Status eth0 Up Subnet Blacklist Rules Ip eth1 Up Subnet Whitelist Rules Jp Cellular Interface Activation Connection IP Address signal Strength pppo S ed Enabled e Weel EVDO REY A atl Teele Disabled Sixnet Wireless Toll Free 800 489 7781 formerly jbm Electronics a baat Fax 314 476 0007 4645 LaGuardia Drive m FO a Fa Web www jbmelectronics com St Louis MO 63134 ad b z WWW Sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual One To One NAT will perform a complete forwarding of all ports on the Original Destination IP to a new IP address entered in New Destination Because the Original Destination need not be configured on this router an interface is not required to setup One To One NAT Range will perform a complete forwarding of all ports for the range of starting ending Original Destination IP s to a range of starting ending New Destination IP addresses entered in
50. Number Copyright 2010 Sixnet LLC NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Save operation succeeded e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Operation Succeeded e Click on the OK button to acknowledge the content IP in IP Tunnels The IP in IP Tunnels menu item allows you to configure a simple IP Tunnel IP in IP Tunnels essentially encapsulates an IP packet into another packet with the same protocol as the transport protocol Click on the IP in IP Tunnels menu item and the following window will appear Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced IP in IP IP in IP Tunnels id Enabled l Local IP Local Subnet Remote IP Remote Subnet Add Delete Sixnet Wireless m Toll Free 800 489 7781 fare ibm Electroni Fax 314 426 0007 4645 LaGuardia Driv
51. Ointernettrial net 2 Enter Password Confirm Password Select APN Context 2 Ar me intemnettral net 2 oT aee ea One Gola Siera Wireless Aincard 875 Enable Modem Auto Detection 2 VewChange Advanced Options Sixnet Wireless Toll Free 800 489 7781 formerty jbm Blectronic Fax 314 426 0007 4645 LaGuardia Drive af _ Web wwwJjbmetlectronics com SL Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Apply button e Verify that you have Internet access by browsing from the computer system connected to the Sixnet router to the Internet There are also Advanced Options available if needed WARNING These options should not be used unless directed to do so by Sixnet support staff Click on the pull down next to the View Change Advanced Options Click on the Yes and the following will be added to the display a red Bay busness 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced _ Cellular Connection O O O O O a Currently Installed Modem Sierra Wireless MC8790 MC8795 Enable Interface ES y Fi z Select Cellular Carrier Enter Password Enter User Name ku Select APN Context Bie APN for context 1 is currently set to i2 gold 3 Confirm Password Enter APN Oveowrites suave context if sat Ei ote eee Siera Wireles
52. Recent Items ak Windows Live Messenger Download Computer o Windows DVD Maker Network El Windows Meeting Space Connect To Control Panel Default Programs Help and Support Start Search p CTE The control panels should look similar to the following XP N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual amp Control Panel File Edit Tools Back view Favorites Help wi P Search Key Folders gt Folder Sync Address Control Panel ne A Vg Control Panel R E Switch to Classic view Z LA Appearance and Themes See Also Lt Pick a category Rp Windows Update 9 Help and Support 6 Other Control Panel Options Cor ea Network and Internet Connections J Sounds Speech and Audio Devices Performance and Maintenance 28 Printers and Other Hardware Q a Y User Accounts Connect to the Internet create a home or small office network configure network settings to work from home or 6 Add change modem phone and Internet settings ne Language and Regional Options Accessibility Options r lt Security Center Vista Windows 7 go gt Control Panel gt e Control Panel Home System and Maintenance Get started with Windows Back up your
53. Reguired Client Source Port Be TCP Server If this option is selected the device will act as a TCP Server and listening on the configured Listening IP Port for connection from the client T P Port Configuration Socket Type TCP UDP Independent Activation No m No OF Allow Peer To Re attach While Connected No l Required Save TCP Headers Listening IP Address Listening IP Port TCP Client Server 2Way If this option is selected the device will listen on configured Listening IP Port for client connection to communicate with serial device and once the client is disconnected and the serial device connected to the ttyS1 port needs to report its status the device will connect to the host destination to report the device s status TCP UDP Port Configuration Sah Ce Clent Server 2Way TCP Headers None Host IP Address Reguired Host IP Port Reguired Client Source Port Allow Peer To Re attach While Connected Listening IP Address Required mo ea a eS be Fe ee e Listening IP Port Required Cancel Save Apply UDP Broadcaster If this option is selected the device will support up to 5 UDP broadcast addresses CONNECT MONITOR CONTRO ner Sixnet Inc A Red Lion Business sala 8 877 8346 a red lion business 331 Ushers Road Ballston Lake NY 12019 T 518 877 5173 F 151 IndustrialPro Series Router User Manual TCP UDP Port Configuration me GEA UDF BroadCaster m o A
54. Rules The Masquerade Rules menu item allows you to configure an interface to give all IP Addresses on a local network access to the Internet e Click on the Masquerade Rules menu item and the following window will appear Status Networking Services Advanced Firewall Masquerade Rules Orig Src Subnet Interface 192 168 0 0 16 All Untrusted 1000 08 All Untrusted 172 16 0 0 92 All Untrusted Sixnet Wireless gs Toll Free 800 489 7781 eriy ibm Electronic Fax 314 426 0007 1645 LaGuardia Drive WebowwwJjbmelectr omcs com St Louis MO 63134 Www sporet com Model Number Copyright 2010 Sixnet LLC To add a new masquerade rule e Click on the Add button and the following pop up window will appear Add Masquerade Rule Interface Original Source Subnet Enter the subnet using IP CIDR notation that will be masqueraded out a specific interface All traffic that is sourced from this subnet and that is destined to go out the specified interface will be masqueraded with the source IP address of the interface specified Required Interface Click on the pull down menu to select the interface through which you wish to masquerade source addresses NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL P red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Add Masquerade Rule Ogle lg ears aT ee 10
55. Scan Rate This is the time in which the screen will automatically refresh values from the internal I ODB Show messages If checked the user will see messages displayed as I O operations are taking place in the background From the Drop Down list select the type of I O you would like to test Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Firefox S Sixnet Administration Utility x 192 168 0 1 10000 Home Scan Rate 5 Show Messages Select Type Start Address 0 Register Count 8 Columns 8 J Analog In Analog Out Discrete In Discrete Out Long In Long Out Float In Float Out Valid I O types are Analog Out Discrete Out Long Out Float Out Once you select the type of I O you will be testing enter your Start Address Register Count and Columns then click the Add to Test I O button You will see the following screen update S Sixnet Administration Utility x 192 168 0 1 10000 W y C SB Googie A f D B Home Scan Rate 5 Show Messages M Si Analogin Start Address 0 Register Count 8 Columns 8 Add To testlO IX net ared Hoan business Added I O Range AI 0 7 to Test I O T O updates continuing ANALOG INPUTS AI0 0 AI1 0 AI2 0 AI3 0 AI4 0 AI5 0 AI6 0 AI7 0 The messages log shows t
56. Sixnet LLC e Click on the Apply button and the following pop up window will appear Firewall settings applied oo e Click on the OK button to acknowledge the content 3 4 5 PPP Dial Backup The PPP Dial Backup menu item allows you to configure the capability of an alternate connection by dialing into an ISDN should the primary route get interrupted Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the PPP Dial Backup menu item and the following window will appear Status Networking Services Advanced PPP Dial Backup Enable PPP Dial Backup No Sixnet Wireless Toul Free 800 489 7781 for merty ibm Electronic lt 4 Fax 314 426 0007 4645 LaGuardia Drive art Web wwwjbmetectronics com St Louis MO 63134 awf e s r 4 Www sienet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu at the Enable PPP Dial Backup field e Click on Yes and the display will expand to reveal the configuration fields Status Networking Services Advanced PPP Dial Backup Enter Dial String Enter User Name Enter Password Conmirm Password Choose Connection Behavior Dial on demand Idle Time Use Default Route Advance Setup Sixnet Wireless Toll Free 800 489 7781 7 Fax 314 426 0007 ormerly jbm
57. System Information Lp 192 168 111 1 DOWN Up 192 168 8 20 Up System Services Syslog Update History Ping Connection IP Address Signal Strength pppO el Enabled 166 130 37 97 UMTS 91 Socket Test i Speed Test Disabled i Traceroute Sixnet Wireless Toll Free 800 489 7781 4645 LaGuardia Drive l Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copyright 2010 Sixnet LLC e Click on the Traceroute menu item and the following window will appear Sixnet Inc A Red Lion Business CONNEC ONITOR COI NU 5 red I business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Traceroute Enter HostiP Address to test SCC RCE ls Unspeched Sixnet Wireless i Toli Free 800 489 7781 y iben Elect Fax 314 426 0007 4645 1 aGuar dia Drive F Webswwwjimnelectronics com St Louis MO 63134 wWww sbmetcom Model Number Copyright 2010 Sixnet LLC Type in the IP Address or URL you wish to trace and click on the Trace button to use any interface that the router determines as having the route to the designated address Status Networking Services Advanced Traceroute Enter HostlP Address to test Required ACEDA Unspecified Trace Route results for www google com traceroute warning www google com has multiple addresses using 74 125 95 105 traceroute to wow l qoogle c
58. Types and Limits Enter Update Interval ms Time interval in milliseconds for the I O transfer Scan Enable Type I O Type used for controlling an I O transfer using either a discrete input or discrete output register Valid options are DI or DO or Blank if not used Scan Enable Address The address of the discrete register used to control an I O transfer Valid values are O through number of registers configured for specified I O type Blank if not used e Click on the OK button to populate the I O transfer Table screen If more than one I O transfer for remote station is needed click and repeat the Add button e Click on the Save button to save the I O transfer configuration in the modbus xml file Table 1 1 O Types and Limits for read commands vom weet PO eeu OO Praga eT TT a OO Number of regs supported in I O transfer Al i o a Table 2 1 O Types and limits for write commands vor Piece Deets PO Number of regs supported in I O transfer Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Table 3 Valid Type Combinations for READ I O Xfers Local Type Valid Remote Type Table 4 Valid Type Combinations for WRITE I O Xfers Local Type Valid Remote Type ooo o C Si X net Sixnet Inc A Red Lion Busines
59. Uptime N A se a EE Disabled Toll Free 800 489 7781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support o gt gt BT 6821 HSPA Copyright 2012 Sixnet Inc e Click on the SNMP Agent menu item and the following window will appear Status Admin Networking Services Advanced Toll Free 800 489 7781 Sixnet Wireless i Fax 314 426 0007 4645 LaGuardia Drive ee Web www sixnet com St Louis MO 63134 m Send Email to Support 52nd Man BT 6821 HSPA Copyright 2012 Sixnet Inc e Select Yes to Enable SNMP Agent option and the following window will appear Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Networking Services Advanced Enable SNMP Agent Community String for SNMP Agent Access nnn Allow Serial Number OID No Toll Free 800 489 7781 Sixnet Wireless P a Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support BT 6821 HSPA Copyright 2012 Sixnet Inc Community String for SNMP Agent Access Specify the community string to use for authentication between the SNMP Agent and Manager Alpha numeric strings are supported Note The community string must match on both ends of the connection in order to wor
60. User Manual 4 Sixnet Technical Support If you have followed all of the instructions up to this point and are not having an authentication problem are convinced that you have sufficient reception and your router is still not communicating please contact Sixnet Technical Support at 1 800 432 9908 We will be happy to help you get your Sixnet router up and running Green Power Connection Status Power Power being received by the JBM router Power not being received by the JBM router Green Connection Status Link JBM router is connected to a network device at 100 Mb JBM router is connected to a network device at 10 Mb Ethernet Ports _ Yellow Link amp Data Transmit Receive Activity Status ON Steady Ethernet port has a Link established with the network device ON OFF ON iaickenna JBM router is transmitting and receiving data packets Green Data Receive Activity Status RXD N OFF ON l i i i ON IBM router is receiving data packets Trys1 DTE Flickering Serial Port Green Data Transmit Activity Status TXD ON OFF ON Flickering JBM router is transmitting data packets N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 ie Sixnet ared Hon business IndustrialPro Series Router User Manual 3 6 6 1 1 SPECIFICATIONS
61. Yes Advertised link modes 10baseT Half i0baseT Full 100baseT Half 100baseT Full Advertised auto negotiation Yes Speed i00Mb s Duplex Full Port MII PHYAD 4 Transceiver external Auto negotiation on Supports Wake on g Yake on d Current message level Link detected yes OxOO000003f 63 Settings for ethl Supported ports TP AUI BNC MII FIBRE Sixnet Wireless former bm Electrori 4645 LaGuardia Dr St Louis MO 63134 Model Number The Summary item will display a brief description of the interfaces of the Sixnet router Advanced Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmetectronics com WWW Sixnet com Copyright 2010 Sixnet LLC The Details menu item will display a more system specific description of the interfaces on the Sixnet router Advanced Toll Free 800 489 7781 Fax 314 426 0007 Web wwwjbmetectronics com WWww sixnet com Copyright 2010 Sixnet LLC O N Sixnet a red Hon business Sixnet Inc A 331 Ushers Road Ballston Lake NY 12019 Red Lion Business CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The Multicast menu item displays the current multicast settings for the interfaces Status Admin Networking Services Home A p Cache Installed Firmware Version Feature Codes Firmware Version Number Firewall Rules Summary Jevice Ser
62. a URL for testing the destination availability Status Admin Networking Services Advanced Home see Arp Cache Installed Firmware Yersion Feature Codes Firewall Rules Firmware Version BRumber Device Serial Number Serial Mumber Cc a eaS a System Processes Physical Interface Status System Services face Connection State IP Address Link Status System Information Up halen cee ROHN i Up 192 168 6 20 Up Syslog Update History Ping Connection IP Address Signal Strength pppo Enabled 166 130 12 34 UMTS 91 Socket Test Speed Test Disabled v kd Traceroute z Sixnet Wireless P ai Toll Pree 800 489 7781 4645 LaGuardia Drive Paxt 314 426 0007 St Louis MO 63134 Webiwww sixnet com Copyright 2010 Sixnet LLC e Click on the Ping menu item and the following window will appear Status Admin Networking Services Advanced Source Interface 127 00 1 wv Sixnet Wireless 5 Toll Pree 800 489 7781 4645 LaGuardia Drive Pax 314 426 0007 St Louis MO 63134 Webiwww aixnet com Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Type in the IP Address or URL you wish to ping and click on the Ping button to use any interface that the router determines as having the route to the designated address It is recomm
63. an entire network that you want to allow access into the network behind the Sixnet router e Click on the Subnet Whitelist Rules menu item and the following window will appear Status Admin Networking Services Advanced Firewall Vhitelists General Behaviors Spinan a aaee No Restrictions v Current Whitelist Groups default 0 0 0 0 0 Individual Whitelist Definitions Name Subnet default 0 0 0 0 0 Delete Sixnet Wireless si Toll Free 800 489 7781 4645 LaGuardia Drive Gh Fax 314 426 0007 St Louis MO 63134 pg Web www sixnet com General behavior setting controls whether or not the whitelist rules apply to packets originating from the Gateway device There are two choices e Only to Whitelisted IPs e No Restrictions default Sixnet Inc A Red Lion Business a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual When Only to Whitelist IPs is selected packets destined for subnets outside those allowed by the selected whitelist will be suppressed by the firewall When No Restrictions is selected the device may send a packet to any subnet and the whitelist rules apply only to packets received e Click on the Add button and the following pop up window will appear Add Whitelist Definition Enter Whitelist name aaaea 19 160 10 0 0 _ Cancel OK Enter Whitelist Name Enter a na
64. and disabling features omaSupported INTEGER Configuration of Device Allow changes to settings and parameters of the device Software Upgrades Provide for new software and or bug fixes to be loaded on the device including applications and system software Fault Management Report errors from the device query about status of device Values are Unknown 1 No 0 Yes 1 currentMipProfile INTEGER Mobile IP Profile Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Electronic Serial Number is a permanent identification number used to esn STRING recognize mobile devices accessing particular telecommunications networks The ESN is assigned and embedded into a wireless communications device by the device s manufacturer Pseudo ESN a reserved ESN manufacturer code 128 which allow legacy pesn STRING equipment to recognize MEIDs med STRING Mobile Equipment Identifier 56 bits long and like ESN s identify the manufacturer of a mobile device as well as the serial number assigned to the device by that manufacturer lowEcio INTEGER Ec lo is a ratio of good to bad energy representing the cell towers cleanness in its signal to you In other words signal to noise ratio highRssi INTEGER High Speed Received Signal Strength Indication highEcio INTEGER Ec lo is
65. are sub sectioned into TCP Only Conn Track and All Status Admin Networking Services Advanced Home trial Pro model_number Administration Utility Arp Cache Installed Firmware Version Feature Codes Fi I Rul firmware revision rewa Ues as Device Senal Number unit serial TCP Only System Processes 2 i eae Conn Track sical Interface Status All action State IP Address Link Status 192 168 111 1 Down 192 168 0 1 Up Syslog C5Q History Update History ice Activation Connection IP Address Signal Strength Not Reg Enabled N A No Service 110 ee Connecting eaae aak Ree ee Disabled hi Toll Free 800 489 7781 Sbmet Wirks P a Fax 314 426 0007 4645 LaGuardia Drive S j X i 3 n t Web www sinet com St Louis MO 63134 SMAC Send Email to Support 52nd Mal model_number Copyright 2012 Sixnet Inc Sixnet Inc A Red Lion Business COI ONITOR COI a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual The TCP Only menu item will display the sockets that are connection oriented also known as stream sockets Click on the TCP Only menu item and the following window will appear Status Networking Services Advanced Socket Statuses TCP Only Active Internet connections servers and established Proto Recv Q Send OQ Local Address Foreign Address State PID Progrs 0 0 0 0 7765 0 0
66. business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Modem Emulator Provides direct connection between the device serial port and the DTE terminal via straight RS232 cable Via Modem This option is only used if the device provides TELCO BPX or RJ11 To Terminal port for communication Recommended Setting Modem Emulator for direct connection Use Timer Only This option needs to be set to Yes in order to use the Inter Character Timeout value configured on this device Recommended Setting Yes Inter Character Timeout ms When the timer expires on the serial port the device will forward the message received to the remote device This option is used when there is no consistent character to signal the end of a received message This timer will be reset to the configured value on each received character Recommended Setting 5 milliseconds at 9600 baud Maximum Buffer Size This option allow you to set the maximum buffer size to be used for receiving serial data before forwarding to the remote device A value of ZERO will allocate 8192 bytes of buffer by default and the data could be sent to the remote application based on TCP stack window size Recommended Setting 292 For DNP3 type connections and 0 otherwise Enable Hardware Flow Control Select Yes to set hardware flow control using RTS and CTS signals Recommended Setting No if dealing with 3 wire port T
67. com St Louis MO 63134 Send Email to Support model_ number Copyright 2012 Sixnet Inc Define Station Properties Station Name Enter the station name that will identify this unit as an RTU Station Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red fgn business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Station Number Enter the number that will be used by other DNP3 devices to address this RTU Station Primary IP Address Enter a valid IP Address that will be used by other DNP3 devices to connect to this RTU Secondary IP Address Enter a valid IP Address that will be used by other DNP3 devices to connect to this RTU in the case the primary address fails to connect Define General Properties Compatibility Mode This RTU supports both Level 2 or Level 2 mode Check the box for the mode your network is utilizing On new event when Event Queue is full Select whether to discard oldest or newest message when log is full Enable Unsolicited Responses Select if the DNP Slave should send unsolicited messages to the DNP Master If this selection is checked then the user should also configure the following 1 The address of the station to which DNP Slave will send unsolicited messages in the DNP Address to Send Unsolicited Messages field 2 The amount of time in milliseconds any events will be allowed to remain in the event queu
68. communication to an interface s local subnet Then proceed to addresses on distant networks Your local default gateway is a good test and this IP can be found in your routing table A commonly available internet server available to test against is 4 2 2 2 Sixnet Inc A Red Lion Business SONNE O R CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The Source Interface offers the option of using different interfaces to send the trace through This is useful should you have a VPN Tunnel in place and testing the connection through the VPN Tunnel is required to verify connectivity through the tunnel e Choose the interface that the VPN Tunnel has listed for the Local Subnet end point i e if the Left Subnet is 10 100 100 0 24 and eth1 has 10 100 100 1 as its IP Address then choose Source Interface eth1 e Specify a host IP Address at the head end to ping through the tunnel e Click on the Trace button to see the result Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 3 Admin Tab The Admin Tab is where the administration of the Sixnet router takes place From here you can configure how the unit is accessed manage SSL IPSEC certificates restore the unit to factory defaults up
69. computer i Vie 5 Classic View Security Check for updates Check this computer s security status Allow a program through Windows Firewall Network and Internet View network status and tasks Set up file sharing Hardware and Sound Play CDs or other media automatically Printer Mouse Programs Uninstall a program Change startup programs Recent Tasks View network status and tasks Connect to a network 1 2 2 Access Network and Internet Settings may Sixnet ared lon business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 User Accounts and Family Safety Set up parental controls for any user Add or remove user accounts 2 Appearance and Personalization Change desktop background Change the color scheme Adjust screen resolution Clock Language and Region SS Change keyboards or other input T methods F Change display language Ease of Access Let Windows suggest settings Optimize visual display Additional Options CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual e Click on the link to access network and Internet settings o XP Network and Internet Connections o Vista Windows 7 Network and Internet The displays should be similar to the following XP amp Network and Internet Connections File Edit View Favorites Tools Help Back
70. computer networking the Maximum Transmission Unit MTU of a communications protocol of a layer is the size in bytes of the largest protocol data unit that the layer can pass onwards MTU parameters usually appear in association with a communications interface NIC serial port etc Standards Ethernet for example can fix the size of an MTU or N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual systems such as point to point serial links may decide MTU at connect time A larger MTU brings greater efficiency because each packet carries more user data while protocol overheads such as headers or underlying per packet delays remain fixed the resulting higher efficiency means a slight improvement in bulk protocol throughput A larger MTU also means processing of fewer packets for the same amount of data In some systems per packet processing can be a critical performance limitation However this gain is not without some downside Large packets can occupy a slow link for some time causing greater delays to following packets and increasing lag and minimum latency For example a 1500 byte packet the largest allowed by Ethernet at the network layer and hence over most of the Internet ties up a 14 4k modem for about one second Recommended Setting 1500 Maximum Receive Idle Time
71. dnusmasg Hpt iptables Drortt ping alive off firegate offt er ipupaate Ds oLfft hotplug J off sbmvall off dhcreiay soff iptrans J off jbmconfig soff network orr syslog J o0ff smcroute J 0rf xinetd off openvpn orr jbmcontigs O off xinetd based services telnet on iw in O uy 5 E US www 0 ma eh he M WAA HA p r X UPAND Ww ef gt wm un Ws Ww wn e oO O wm uy i oO oe eee nN Ww www w D D tb db a em te de gt le ob f fy 9 fe sf H tj oO E 1 Ao fr W Ww ib 9 ODO MAMARA AMA d iw Ww amp A oe ee ee ee ee ee ee ee ee ee ee o gt lh muwGuww eo J gt O Ide 0 E V W U Qi D D D m U t gt e O ef WwW Ww te mow o O W ta w amp gt amp amp Db gt J J un uf 5 o w D D D D D D v U B wm ot OOO i en ee ee 4 ne oe a 0 _ ji Ww OJ do Q9 a VA D aaa r wor ve Fe hw LEA bee DRS a a LDU 5 W Ww w amp ob mui ft D H A ns a a is i es ee oe T Oo Sixnet Wireless Toll Free 800 489 7781 senariy ibm Elect Fax 314 426 000 7 1645 LaGuardia Drive r Web wwwJjbmelectromcs com St Louis MO 63134 a Wwww spmet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business NNEC ONI NTROL 8 877 8346 a red lion business 331 Ushers Road Ballston Lake NY 12019 Ta 518 877 5173 Fal 51
72. dport 1000 i Toll Free 800 489 7 781 Sinet Wireless Fax 314 4276 0007 4645 LaGuardia Drive Web www scinet com St Louis MO 63134 Send Email to Support model number Copyright 2012 Sixnet Inc NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The All menu item will display the sockets that are considered connection oriented and connectionless also known as datagram sockets Click on the All menu item and the following window will appear Status Networking Socket Statuses Active Internet connections servers and established Proto Recv Q Send O ooooooooocaoaooaqcaos7 oooo0ooocoo0oo0occoaocaeo Local Address 0 0 0 0 7785 0 0 0 0 10000 0 0 0 0 53 0 0 0 0 23 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 192 168 0 1 10000 0 0 0 0 32768 0 0 0 0 53 Foreign Address 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 192 165 0 2 4440 192 168 0 2 4437 192 166 0 2 4432 192 166 0 2 4433 192 168 0 2 4435 192 168 0 2 4434 192 166 0 2 4439 192 166 0 2 4436 192 168 0 2 4431 0 0 0 0 0 0 0 0 Services State LISTEN LISTEN LISTEN LISTEN ESTABLISHED Advanced PID Progra 1623 gmu_1 1530 boa 1542 dnsma 1522
73. entered click Apply N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 4 2 DNS Settings The Domain Name Server Settings screen is broken down into two components The top section pertains to the DNS resolver configuration and the bottom section pertains to the host configuration Click on the DNS Settings menu item and the following window will appear Status Networking Services Advanced DNS Settings Erter Search Domain a Enter Primary ONS Server Enter Alternate DNS Server 1 Enter Alternate DNS Server 2 Host Name Domain _ IP Address Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electron gt Fax 314 426 0007 1645 LaGuardia Drive Webowww_jbmetectronics com St Louis MO 63134 WWw sixnet com Model Number Copyright 2010 Sixnet LLC The Primary Alternate 1 and Alternate 2 DNS server fields are already filled in they are the current servers in use by the Sixnet router Search Domain Enter the local domain name s to be searched separated by spaces These domains are used as the default local domains when performing DNS queries Example local net domain com Primary DNS Server Enter the IP Address of the Primary DNS Server you want to use Required Note This setting may be overridden if a network interface is set to obtain
74. for use with keyed GRE Key is either a number or an IP address The Outbound Key is used for output only Optional Time To Live Set a fixed Time To Live for tunneled packets Optional Note Values over 64 may cause connection failures Use Multicast Select Yes to enable Multicast for the tunnel Use ARP Select Yes to enable ARP for the tunnel N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Han busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Start Tunnel at boot Select Yes to allow the interface to become active at system start Add GRE Tunnel x Tunnel Name Enable Tunnel Local IP Address Local Subnet Remote IP Address ait ead atm 295 255 255 252 fete ee lt Some Key String gt Smot as lt Some Key String gt Time To Live E Use Multicast Use ARP Start Tunnel at boot Cancel f OK __ e Click on the OK button to populate the GRE Tunnels screen Status Networking Services Advanced GRE GRE Tunnels Name Enabled Local IP Local Subnet Remote IP__ Remote Subnet p atm grel Yes 192 168 1 1 255 255 255 0 205 65 36 195 255 255 255 252 Edit Duelate Cancel ff Save Apply Sixnet Wireless s Toll Free 800 489 7781 marty ibm Blectros Fax 314 426 0007 4645 LaGuardia Drive Web www jpmelectronics com St Louis MO 63134 www sbaet com i Model
75. klips pftkey natt x509 private g plutodebug control parsing ONLY enable plutodebug all or kKlipsdebug all if you are a developer NAT TRAVERSAL support see README NAT Traversal nat traversal yes virtual private v4 10 0 0 0 5 v4 192 166 0 0 16 v4 172 16 0 0 12 enable this if you see failed to find any available worker nhelpers 0 Add connections here sample VPN connections see etc ipsec d examples _ Cancel Defaut Save Stop Re Start_ Sixnet Wireless formerty jbm Electromos 4645 LaGuardia Drive St Louis MO 63134 a Toll Free 800 489 7781 Fax 314 426 000 7 Web www jibimelectr onics com Www s met com Model Number Copyright 2010 Sienet LLC Your choice will load the given sub system s configuration file into the text box for editing N Sixnet a red Hon business CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 IndustrialPro Series Router User Manual The following controls buttons are available e Cancel Reload the file in to the text box removing all unsaved changes e Default Load a default file in to the text box for editing All changes to the default file will be reflected in the real rather than the default configuration file e Save Save the contents of the text box in to the real sub system configuration file e Stop Stop th
76. locate the program click on the cmd program it finds Verify connectivity to the router by running a ping to the IP Address of the Ethernet port you are connected to METHOD 1 PC to WAN ETHO on R3000 M1000 A2000 Series Ethernet on SN 6000 Type in ping 192 168 0 1 lt ENTER gt The display should look similar to the following N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 METHOD 2 PC to ETH1 LAN R3000 Series only Type in ping 192 168 1 1 lt ENTER gt The display should look similar to the following IndustrialPro Series Router User Manual Em C Windows system32 cmd exe Microsoft Windows Version 6 86 6681 1 Copyright lt c 2666 Microsoft Corporation All rights reserved Co lt Users s Some Username gt ping 192 168 8 1 Pinging 192 168 0 1 with 32 bytes of data Reply from 192 168 0 1 bytes 32 time 15ms TTL 128 Reply from 192 168 6 1 bytes 32 time 1ms TTL 128 Reply from 192 168 60 1 bytes 32 time ims TTL 128 Reply from 192 168 0 1 bytes 32 time ims TTL 128 Ping statistics for 192 168 60 1 Packets Sent 4 Received 4 Lost A CH loss Approximate round trip times in milli seconds Minimum ims Maximum 15ms Average 4ms C Users Some Username gt Em C Windows system32 cmd exe Microsoft Windows Version 6 6 6681 Copyright lt c 2666 Microsoft Cor
77. lon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual fragment the serial data packets A higher value will collect a larger amount of data into a single TCP packet and will generally keep packet boundaries more intact Visa Mode Unused Recommended Setting 150 Transactions 10 Some Streaming Protocols ATM Management Protocols Data Mode The following data mode is supported 8N1 Data will be treated as full 8 bits valid If the serial device is transmitting 7E1 then 7E1 formatted data will be transmitted to the TCP side 7E1 Process Data as if in 7E1 format If the serial device is transmitting 7E1 then appropriate parity will be stripped added so that communication on the TCP side will be in 8N1 Recommended Settings Transparent Mode As needed for various serial devices and TCP hosts Visa Mode Leave this setting at 8N1 Automatic 7E1 detection is used Spoof ENQ ENQ behavior in supported Message Mode Transparent Mode This will enable an ENQ packet to be sent to the serial device to initiate a transaction Up to 5 ENQ s will be sent while wait Visa Mode Unused The Visa engine will automatically issue ENQ s as needed according to the Gwlnx config file Recommended Setting No No Rx Before Tx Discarding data before transmitting in supported Message Mode Transparent Mode This will discard any data received from the serial s
78. mask for the appropriate IP settings Default gateway Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses IP address Preterred ONS server ae dl Alternate DNS server Sara Subnet mask Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IP V R Series Router User Manual METHOD 1 PC to WAN ETHO on R3000 M1000 A2000 Series Ethernet on SN 6000 e Select Use the following IP address and fill in the blank fields with the information below e IP address 192 168 0 2 e Subnet mask 255 255 255 0 e Default gateway 192 168 0 1 e Preferred DNS 192 168 0 1 You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 197 168 0 Default gateway 197 168 0 Obtain DNS server address automatically Preferred DNS server 192 168 0 Alternate DNS server e Click OK e The previous screen will appear e Click OK
79. on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual DMZ Host Rules Firewall DMZ Host Rules are used to configure rules to route through a Demilitarized Zone DMZ e Click on the DMZ Host Rules menu item and the following window will appear Status Networking Services Advanced Firewall DMZ Host Rules Interface DMZ Host Address Source Whitelist Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com WWW sixnet com Sixnet Wireless 46451 aGuar dia Drive St Louis MO 63134 Model Number Copyright 2010 Sienet LLC To add a DMZ host rule e Click on the Add button and the following pop up window will appear Add DMZ Host Rule a eee All Untrusted DMZ Host Address Source subnets wa Whitelist Select Interface Click on the pull down menu to choose an interface that will be forw
80. packet is received for the specified time then the connection is reset This can be useful for detecting an unresponsive situation where the network is down the modem is in an unknown state or another low level error may have occurred Default is 150 seconds however you can use 0 to turn this function off NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual NOTE If the normal usage of the device regularly has packets leaving the unit with no expected response then premature disconnections may result Outgoing UDP packets with no expected response may be normal operation yet will trigger this disconnection and reset Modem Select Yes to use the modem control lines CD Carrier Detect and DTR Data Terminal Ready RTS CTS Select Yes to set hardware flow control using RTS and CTS signals Modem Speaker On e Yes For testing and proof of concept phase to audibly verify connection attempts e No For silent production mode Enter Custom AT command Enter the modem initialization string Please consult your modem AT Command documentation for unique initialization that may be required Enter only a single initialization string e Click on the Apply button and the following pop up window will appear AN PPP Dial Backup configuration applied e Click
81. ports that is authorized access through the firewall on the Sixnet router e Click on the Service Access Rules menu item and the following window will appear Networking Services Advanced Firewall Rules Start Port End Port Interface Protocol Source Whitelist 7785 7785 AllUntrusted TCP default Sixnet Wireless Toll Free 800 489 7781 ormerty jbm Glectror cs Fax 314 426 0007 4645 LaGuardia Drive Web wwwjbmelecironics com St Louis MO 63134 WWW Sixnet com Model Nurnber Copyright 2010 Sixnet LLC To add a new Service Access Rule e Click on the Add button and the following pop up appears Add Service Access Rule Stating Port Ending Port Interface Sdect Protocol Source network via Whitelist Starting Port Enter the starting TCP or UDP port number for this rule Required NOTE If adding only one port enter it here NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Ending Port Enter the ending TCP or UDP port number for this rule NOTE If adding only one port please omit this entry Interface Select the interface on which this port will be opened Incoming connections to this interface will be allowed into the device Note For connections destined to a device beyond this unit use Host Redirect NAT or DMZ rules i
82. s Fax 314 426 0007 4645 LaGuardia Drive Web wwwjomelectronics com St Louis MO 63134 Www sbcnet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu at the Enable Dynamic DNS and the display will expand to reveal the configuration fields shown below N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Dynamic DNS Enable Oynamit ONS Select Service Type Emer User Name Enter Password Confirm Password Select interface Host Name SC m embers dhs org 80 ea ieee ee NICHOSIS Sixnet Wireless m Toll Free 800 489 7781 for marty iben Electronic i Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelecironics com St Louis MO 63134 www shomet com Mode Number Copyright 2010 Sixnet LLC Select Service Type Select the desired Dynamic DNS Service from the list provided Enter User Name Enter the User Name used to access your Dynamic DNS service in this field Enter Password Enter the Password used to access your Dynamic DNS Service in this field Confirm Password Re enter the Password used to access your Dynamic DNS Service in this field Select Interface Specify the interface you want to access via Dynamic DNS Changes made to the interface configuration after enabling Dynamic DNS will resul
83. says Operation Succeeded e Click on the OK button to acknowledge the content 3 6 6 GWLNX 3 6 6 1 Serial IP Sixnet Cellular Routers in the IndustrialPro and EnterprisePro series support Serial IP via the Advanced Gwlnx7 gt Serial IP configuration menu screen The Serial IP menu item allows you to configure serial communication such as POS device serial data logging or serial transmitter via serial cable on the Sixnet router and third party UDP or TCP IP Client Server application Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 Status Ethernet Interface usb etho IndustrialPro Series Router User Manual Admin Networking Services Installed Firmware Version Firmware Version Device Serial Number Serial Number Physical Interface Status Connection State IP Address Up 192 168 111 1 Up 192 168 0 1 Cellular Interface Activation Connection IP Address N A Cellular Uptime Select auto update interval Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Model Number Unavailable Disabled N A N A Disabled Sixnet Advanced IP Fallback _ Model Number Administration Utility IP Transparency Qut of Band Mgt VRRP Connect Table Configuration Install Application Link Status Down Up Manage Configurations Install Configuration
84. scroll display to end Enter optional filter string Ei Select of lines to display i Ei Enable Auto update l Ei Select update interval E Toll Free 800 489 7781 Fax 314 420 0007 Sixnet Wireless a Web www sixmet com 4645 LaGuardia Drive H ee F oo Send Email to Support gt n Mail Model Number Copyright 201 Sixnet LLC Enter optional filter string Enter a filter string in the space provided only lines containing the filter value s will be displayed via a grep style filter mechanism Note that the filter is case sensitive Select of lines to display Select the number of lines to be displayed from one of the choices in the drop down list provided Choices include e 50 e 100 e 250 e 500 e 1000 e 2000 NU a red lion business Sixnet Inc A Red Lion Business COI ONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Recommended Setting Be advised that when connected via a Cellular interface the log file data collected will count towards your total data plan usage Enable Auto update Select Yes to enable automatic updating of the log file display the update interval can be selected using the Select Update Interval provided immediately below this control Manual updating is disabled while auto update is in effect The current filter and maximum lines to be displayed will be used Reco
85. the TCP host processor of Visa transactions Visa Messages from the ATM POS device will conform to STX Payload ETX LRC After Visa processing and validation the format sent to the host will be Default Use the current settings in the Gwlnx configuration Payload Only Strip Visa header trailers Send only the Payload Payload ETX Strip the Visa header and LRC block check STX Payload ETX Strip only the LRC block check STX Payload ETX LRC Send the fully formatted Visa message Recommended Setting Default Header Type The TCP connection to a host may require length headers This will optionally be prepended to the data received from the serial side for either Transparent or Visa Mode Default Use current Gwinx configuration None Use no headers JBM Standard Use JBM Standard Headers This will prepend a Two Byte Length 2BL Header to the data indicating the number of bytes in the message not including the header bytes Messages from the host must also have the 2BL header to be received properly NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Example With Host Message Format set to STX Payload ETX and JBMSTD Headers used the TCP message sent to the Host will be XX XX STX Payload ETX Where XX XX would be the length of the payload data plus 2 STX and
86. the following pop up window The page at http 1 P Address 10000 says Operation Succeeded If you selected the DOWNLOAD method you may click the link when the page refreshes Otherwise the file has been sent via FTP e Click on the OK button to acknowledge the content N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Click on the link that appears under the Download field once the page is refreshed Status Networking Services Advanced Gather Configs include all jbm files No 2 Include gwinx files Yes include all network fles Yes Sees a Dowmload v Chek Link to Download Fa Sixnet Wireless i Toll Free 800 489 7781 nerly jbm Electroni 2 Fax 314 426 0007 4645 LaGuardia Drive Webowww_jbmetectronics com St Louis MO 63134 n z www sixnet com Model Number Copyright 2010 Sixnet LLC o The download pop up window will appear click OK to save the file to your computer system o If you are uploading the zipped config file to the Sixnet FTP site or to a site of your choosing click on the pull down menu next to Select Delivery Method and choose FTP The display will change to reflect additional options for FTP ing the file to either the Sixnet FTP site or to a site of your choosing Status Ne
87. the following pop up window will appear The page at http lt IP Address gt 10000 says Operation Succeeded e Click on the OK button to acknowledge the content 3 5 3 SN Proxy SN Proxy is a web relay proxy service used to gain access to devices that are behind our Sixnet router providing additional security and access control to devices that may not offer such functionality A Proxy based service provides a more robust connection than just using a port forward rule including the ability to add an additional user log in for authentication encryption via SSL as well as isolation via Access Control Lists To begin using SN Proxy Click on Services gt SN Proxy Settings and the following window will appear Status Admin Networking Services Advanced SNProxy Settings Enable SNProxy Settings No Toll Free 800 489 7 781 Sinet Wireless ai Fax 314 4276 0007 4645 LaGuardia Drive Web www sinet com St Louis MO 63134 Send Email to Support model_number Copyright 2012 Sixnet Inc Enable SN Proxy Settings Enables or disables the SN Proxy feature NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual When you click yes to enable the feature the following window will appear Status Adm in Networking Services Advanced SNProxy Settings En
88. the following window will appear Status Networking Services Advanced SixView Manager Current Client Status ENABLED Next Check in 23 minutes 35 seconds Reporting to Wwewiiriyomu com Enable OMU Access Yes SixvView Manager Server Primary Address bwwwmygmy com Tegude SaView Manager Server Secondary Address aa Enter Access Interval minutes 240 Faduire Enter Error interval minutes Tegwrec Seen Unencrypted hto Enter SkView Manager ServerPont 1 39080 teguiret Select interface None z Enter Rapid Check in interval oS Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electronic Fax 314 4256 0007 1645 LaGuardia Drive r Aa Web wwwjbmetectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sixnet LLC SixView Manager Server Primary Address Enter the IP Address or host name of your SixView Manager primary server NOTE When changing the Primary Address to your own private SixView Manager server you may want to consider setting the Secondary Address to the Sixnet SixView Manager test server www mygmu com for trial and initial production rollouts This will enable Sixnet support staff to monitor the progress and better assist in diagnosing potential problems SixView Manager Server Secondary Address Enter the IP Address or host name of your SixView Manager secondary server Sixnet Inc A Red Lion Business COI ONITOR COI a red lion business 331 Ushers Road B
89. the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference to radio communications in which case the user will be required to correct the interference at their own expense Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Information to the User If this equipment causes interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures In order to meet FCC emissions limits this equipment must be used only with cables that comply with IEEE 802 3 If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet
90. them to the Sixnet support personnel for review e Click on the Gather Configs menu item and the following window will appear Status Networking Services Advanced Gather Stats include IPSEC Barf output ves include gwtnx log files Yes Select Delivery Method Sixnet Wireless P ai Toll Free 800 489 7781 for merty jbm Electronic Fax 314 426 0007 4645 LaGuardia Drive Web www itnelectr onics com St Louis MO 63134 WWw spinet corm Model Number Copyright 2010 Sixnet LLC To gather the configurations of the Sixnet router e Choose whether you want to include all of the Sixnet files by clicking on the pull down menu next to Include all Sixnet files and choose No or Yes These files are located in the etc Sixnet directory e Choose whether you want to include the GWLNX files by clicking on the pull down menu next to Include gwlnx files and choose No or Yes These are the files that control Protocol Conversion e Choose whether you want to include the network files by clicking on the pull down menu next to Include all network files and choose No or Yes These files include the Ethernet interfaces and GRE interfaces e Choose the method of delivery o Ifyou are downloading the zipped config file to your computer system click on the pull down menu next to Select Delivery Method and choose Download o Click on the Gather button You will get
91. to Send Allowable Test Packet Loss Select a debugging level 10 Sixnet Wireless Toll Free 800 489 7781 formerly jbm Electronicos Fax 314 426 0007 4645 LaGuardia Drive af Web www jbmel ctronics com St Louis MO 63134 WWW Sixrel com Model Number Copyright 2010 Sixnet LLC Select Primary Interface Specify your desired primary interface for IP Fallback behavior Select Primary External Command Script Choose the name of the command script to be executed when the associated interface becomes active For example if an ipsec_restart is an option then when selected will be run whenever the fallback logic selects and activates this interface Recommended setting is None for standard operation with no special behaviors ipsec_restart is useful when using an IPSEC VPN tunnel Select Secondary Interface Select the secondary interface to be used for IP Fallback Selecting vrrp will coordinate with the VRRP process so that when the primary interface is determined to be unavailable VRRP will stop broadcasting availability Select Secondary External Command Script Choose the name of the command script to be executed when the associated interface becomes active For example if an ipsec_restart is an option then when selected will be run whenever the fallback logic selects and activates this interface Recommended setting is None for standard operation with no special behaviors ipsec_restart i
92. value must match in any VRRP partner s configuration for redundancy to operate correctly Enter VRRP Group ID Specify the ID number of the virtual server NOTE This value must match in any VRRP partner s configuration for redundancy to operate correctly Multiple VRRP Virtual interfaces can operate on the same subnet so long as each set of redundant partners uses a different ID Enter VRRP Priority Specify the priority to use in VRRP negotiations Valid values are 1 255 Required NOTE If the SIXNET router is the Master device the priority should be set higher than the Backup device Enter VRRP Peer Notification Interval in seconds Specify the amount of time in seconds between VRRP broadcast packets Sixnet Inc A Red Lion Business SONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the VRRP configuration table screen Status Admin Networking Services Advanced RRP Configuration Table Enabled Interface Use Virtual MAC Addesss RRP IP Address YRRP G Yes etho yes 192 168 110 192 25 Sixnet Wireless z i Toll Free 800 489 7781 4645 LaGuardia Drive Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP A
93. variation Binary Counter Objects 20 Binary Counter Combo Box that shows the different choices for Object 20 Binary Counters that the user can select as a default variation 21 Frozen Counter Combo Box that shows the different choices for Object 21 Frozen Binary Counters that the user can select as a default variation 22 Binary Counter Change Combo Box that shows the different choices for Object 22 Binary Counters Change Events that the user can select as a default variation 23 Frozen Counter Change Combo Box that shows the different choices for Object 23 Frozen Binary Counters Change Event that the user can select as a default variation only on Level 2 Click on Save to preserve your configuration before moving on to any other pages Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 6 Advanced Tab The Advanced Tab is where you can configure the magic of the Sixnet router which includes IP Fallback IP Transparency Out of Band Management VRRP Expert Mode and Gwlnx Protocol Translation Status Admin Networking Services Advanced IPF Fallback IP Transparency Installed Firmware Version Out ofBand lgt Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP A
94. will be considered dead and remove the SA Recommended setting is 30 60 seconds Local Public IP Address This parameter typically only needs to be specified when the Sixnet router is configured to use more than one external untrusted interface This parameter specifies the IP address of the left participant s public network interface For example if the Sixnet router has an external cellular interface ppp0 and an external Ethernet interface that is connected to a cable or DSL modem and you need to bind the tunnel s crypto endpoint to the Ethernet interface you would specify the IP address of the appropriate Ethernet interface here Note If this value is omitted it will be filled in automatically with the local address of the default route interface as determined at IPSEC startup time If this parameter is not needed it should be left blank Local Source IP Specify the Local IP Address to source when transmitting The IP address for this host to use when transmitting a packet to the other side of this link Relevant only locally the other end need not agree This option is used to make the gateway itself use its internal IP which is part of the leftsubnet to communicate to the rightsubnet or right Otherwise it will use its nearest IP address which is its public IP address This option is mostly used when defining subnet subnet connections so that the gateways can talk to each other and the subnet at the other end without
95. www jtunelectronics com Wwww sixneLcom Sixnet Wireless forreerly jbm Electror 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC e Type inthe IP Address or URL or the NTP Server location e Choose the Update frequency from the pull down menu Hourly Daily or Weekly e Click on the Apply button ie Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 4 Networking Tab The Networking Tab allows you to configure aspects of the Sixnet router that affect the networking functionality of the unit From here you can configure the cellular connection should the air card SIM not be recognized at power up provision certain functionality on specific air cards configure DNS Ethernet Interfaces Firewall PPP Dial Backup on units available with dial capabilities PPPoE Static Routes TCP Keep Alives and VPN Tunnel configuration Status Admin Networking Services Advanced DNS Settings Instal n Firr PPP Dial Backup EE PPP over Ethemet Static Routes TCP Global Setings Phy Ethernet Interface Connection State IP Address Link Status ethO Up 192 168 0 1 Up eth1 Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppo ho Do 1 10 16 E mel rle Ee pa Ob esa ee EVDO REV A 82 SCRE Mun EELE
96. xinet 1530 boa TINE_WAIT TINE WAIT TINE WAIT TINE WAIT TINE WAIT TIME WAIT TIME WAIT TINE WAIT 1542 dnsma 1542 dn2ame Active UNIX domain sockets servers and established RefCnt Flags Type State I Node PID Programn name 12 DGRAM 111 651 syslogd DGRAN 19291 10434 gau DGRAM 1060 1561 gpsc DGRAM 1058 1580 um_vatch DGRAM 972 1571 jbmeontrol DGRAMN 960 1555 bminit DGRAM 949 1550 crond DGRAM 939 1842 dnsmasq DGRAM 911 1530 boa DGRAM 691 1522 xinetd DGRAM 120 8S6 kiogd Path dev log N NN NH WN Wh CP td Gi GS eee ee RA FR FRA FS FRA FR FR FR F CS loll Free 800 489 7 781 Fax 314 426 0007 Webkwww bmelectronics com www sixnet com Sixnet Wireless for arly ibm Electro 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC NU Sixnet a red Hon business CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 IndustrialPro Series Router User Manual 3 2 7 System Processes The System Processes menu item will display the current running processes on the Sixnet router Status Admin Networking Services Advanced Home Arp Cache 7 Installed Firmware Version Feature Codes Firmware VYersion Number Firewall Rules Device Serial Number Serial Number cystern Processes System Services Physical Interface Status system Information Connection State IP Address Li
97. 0 0 10000 0 0 0 0 53 0 0 0 0 23 0 0 0 6 0 0 0 0 0 0 0 0 0 0 8 LISTEN LISTEN LISTEN LISTEN 1623 gmu_1 1530 boa 1542 dnsma 1522 xinet 9 9 166 0 2 4432 166 0 2 4431 ESTABLISHED 1530 boa o 192 168 0 1 10000 1 1 TIME WAIT 192 168 0 1 10000 0 2 2 Toll Free 800 489 7781 Fax 314 426 0007 Webkwww jdbmelectronics com WWW Sixnetcom Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC N Sixnet a red Hon business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Conn Track is a connection tracker that displays more thorough information about the current socket connections Connection tracking allows the kernel to keep track of all logical network connections or sessions and thereby relate all of the packets which may make up that connection NAT relies on this information to translate all related packets in the same way and iptables can use this information to act as a stateful firewall Click on the Conn Track menu item and the following window will appear Admin Networking Services Advanced 6 431998 ESTABLISHED src 192 168 0 2 dst 192 1668 0 1 sport 57135 dport 17 157 src 127 0 0 1 dst 127 0 0 1 spert 2048 dport 53 packets 20 byte 6 118 TIME WAIT src 192 168 0 2 dst 192 168 0 1 sport 57134
98. 000 RX bytes 62290 60 8 Kb TR bytes 356237 347 8 Kb Base address 0xa000 Link encap Local Loopback inet addr 127 0 0 1 Mask 255 0 0 0 UP LOOPBACK RUNNING MTU 16436 Metric 1 RX packets 556 errors 0 dropped 0 overruns 0 frame 0 TX packets 556 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 0 RX bytes 34362 33 5 Kb TX bytes 34362 33 5 Kb Sixnet Wireless orme Electronios 4645 LaGuardia Drive St Louts MO 63134 erly ibn Model Number Status Networking Services interface information Details e ethO lt BROADCAST MULTICAST UP 10000 gt mtu 1500 qdise link ether 00 60 da 02 44 95 bra fr fr ffr ff ff ff inet 192 168 0 1 24 brd 192 168 0 255 scope global ethi lt BROADCAST MULTICAST UP 10000 gt mtu 1500 qdisc link ether 00 60 da 02 44 96 brada 2 f f ff inet 192 168 1 1 24 br 192 168 1 255 scope global lo lt LOOPBACK UP 10000 gt mtu 16436 qdisc noqueue link Loopback 00 00 00 00 00 00 brd 00 00 00 00 00 inet 127 0 0 1 8 brd 127 255 255 255 scope host lo GummyO lt BROADCAST NOARP gt mtu 1500 qdisc noop link ether 96 Sa fc 97 f3 c2 brd ff ff ff ff tf tft t tunlO lt NOARP gt mtu 1480 qdisc noop link ipip 0 0 0 0 bra 0 0 0 0 pfifo fast qien 1000 etho ptifo_fast qien 1000 ethi 00 Settings for eth0 Supported ports Supported link modes TP AUI BNC MII FIBRE 10baseT Half i0baseT Full 100baseT Half 100baseT Full Supports auto negotiation
99. 000 says IP Failover settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says IP Failover settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 6 2 IP Transparency IP Transparency is supported on Sixnet Routers in the IndustrialPro and EnterprisePro series To configure IP Transparency select the option from the Advanced menu The IP Transparency menu item allows you to configure the transparent bridging capability of the SIXNET router IP Transparency is a special use capability IP Transparency will take all inbound traffic to the SIXNET router and pass it transparently through to the interface specified This is useful when it is desired to pass traffic to a legacy firewall or VPN concentrator located behind the SIXNET router and not to use the firewall or VPN capabilities of the SIXNET router itself Status Admin Networking Services Advanced IF Fallback IP Transparency Installed Firmware Version Out o Band hat Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Et
100. 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 1 3 1 Sixnet Router Login Instructions e User Name enter admin lowercase letters e For Password enter six digit serial number of router lowercase letters Upon successfully logging in you will be presented with the following screen NOTE The following information can be used for all series of routers even if screen shots indicate other models Some models may have reduced options Status Adm in Networking Services Advanced device_family Administration Utility Installed Firmware Version firmware revision Device Senal Number serial number System Uptime OD OH 54M 405 Ethernet Interface Connection State IP Address Link Status usb Up 192 168 111 1 Down etho Up 192 168 0 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppo Reg Home Enabled 166 130 37 97 HSPA 9i Cellular Uptime OD OH 52M 515 S Ce aat E A Disabled id Toll Free 800 489 7 781 Sixnet Wireless l l Fax 314 426 0007 4645 LaGuardia Drive a ii Web www sxnet com St Louis MO 63134 Send Email to Support 5000 Mal model_number Copyright 201 Sixnet Inc At this point you are connected to the Sixnet router and can configure it to meet your needs Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 Industria
101. 100 100 10 24 Interface e Click on the OK button to populate the Masquerade Rules screen Status Networking Services Firewall Masquerade Rules Orig Src Subnet Interface 192 168 0 0 16 All Untrusted 10 0 0 0 8 AJl Untrusted 172 16 0 0 12 All Untrusted 10 100 100 0 24 ethd Sixnet Wireless formerly ibe ca ry 4645 LaGuardia Drive St Louis MO 63134 Model Number e Click on the Save button and the following pop up window will appear e Click on e Click on NU Sixnet a red Hon business Firewall settings saved Advanced Toll Free 800 489 7781 Fax 314 426 0007 Web wwwjbmetectronics com WWW socnet com Copyright 2010 Sixnet LLC The page at http lt IP Address gt 10000 says the OK button to acknowledge the content the Apply button and the following pop up window will appear Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The page at http lt IP Address gt 10000 says a _ Firewall settings applied e Click on the OK button to acknowledge the content Network Address Translation NAT Rules The NAT Rules menu item allows you to provide access to the Internet through a single machine that translates the IP addresses The NAT itself has one or more IP addresses but all the machines behind the
102. 134 Model Number Admin Networking Services Advanced Installed Firmware Version Firmware Version Number Device Serial Number Serial Number Physical Interface Status Connection State IP Address Link Status Lp 192 168 0 1 Up Up 192 168 1 1 Lp Activation IP Address 72 101 201 21 Connection Enabled Signal Strength E A id Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com WWW sixnet com Copyright 2010 Sixnet LLC Home The Home option will always return the user to the Home Screen pictured above that shows a system info summary NU a red lion business Sixnet Inc A Red Lion Business CONNEC ONITOR COI 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 2 1 ARP Cache The ARP cache is a table which stores mappings between Data Link Layer OSI Layer 2 addresses and Network Layer OSI Layer 3 addresses This important information shows what connections are established to the router Status Admin Networking Services Advanced dest device_family Administration Utility lt o Arp Cache Installed Firmware Version Feature Codes d firmware revision Firewall Rules Device Serial Number serial number System Processes System Uptime System Services DO Si aM 3905 System Information Physical Interface Status Connection State IP Address Link St
103. 173 F 1518 877 8346 IndustrialPro Series Router User Manual Recommended Setting No If you wish to only gain access to this device s web interface and have another connection from your PC out to the internet Yes If you wish to gain access to the internet through this device Enter Starting Address Enter the Starting IP Address of a range you want the DHCP Server to provide for clients Enter Ending Address Enter the Ending IP Address of a range you want the DHCP Server to provide for clients WARNING Care should be used to ensure that there is no conflict with any pre existing devices on that subnet which may have been already configured to use statically assigned IP addresses View DHCP Leases Check this box to display the current DHCP leases logged on the unit The format of this file is documented in the ghcpd leases 5 manual page This lease file was written by isc dhcp 4 1 1a gexrver duid 000 001 000 001 027 354 016 002 352 214b 027 030 243 View DHCP Leases Distribute DHCP Leases Based on MAC Address To assign IP to a device based on MAC address so that device obtains the same IP each time it requests a new IP from the DHCP server click Add to enter the MAC and IP information for that specific client Distribute DHCP Leases Based on MAC Address Add Distribute DHCP Leases Enter Client MAC Address fF Enter Client IP Address fs Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CON
104. 19 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e The following warning pop up window will appear The page at http lt IP Address gt 10000 says eS This action will cause the device to update its Master Configuration file using the import file previously uploaded After this has been completed the pre existing configuration will have been replaced by the newer settings the old settings will no longer be available unless you d previously exported and saved them At the completion of this action you will then have the option of either rebooting the device which will apply al of the new setings to the system or manually applying the new settings to each affected subsystem In either case these settings may result in changes in the configuration of one or more network interfaces Depending on the nature of these changes your connection could be lost Incomplete or incorrect network settings could render the device incommunicable Are you sure you want to proceed Cancel CD e Click on the OK button to acknowledge the content e Anew window will open below the Upload and Import buttons N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red ln busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Import GAU Maste
105. 232 Connections to Sixnet ROULCTS csccccccsasccacscicicaucececivcasavi asd sansaatacdsieacevescacssaceisassssccesiecdudadeasosis 19 2 CEFLEULAR CONNECTIONS cernir E E E tas doasas ose soe satcepoestaneGechs aimoieaeveniacseice 19 21 CELLULAR CARD CONFIGURATION secsozedocssnesncassnandoc bonne seesnacdsabesaasgaonnentoasducansaoneantoabaaens Saeseandeabonneroaemnendoabinemesanboandeabssannsangenndeooanns 19 21d Celular Carr erol hOn ereere es E E onc duced EEE E EEEE EEE a a e 20 2 1 2 Set the User Name Password and APN ccccccccccccccccsssccccccueeseccecasseceeeauseeceeeaueeeceeeuuseeceesaaeeeceeeuaseceeesuaeeceeeauaaeceeeaaaeeeeesanes 21 2 1 3 Enter Provisioning Information if ADPlicAble cccccccccccccssseeseccecceee ee eeeeeeeeeeeeeaeeeeeeeeeeeaaaeeeeeeeeeeeaaaaeseeeeeeeeaaaasseeeeeeseaaaaeseeess 21 2a VERMY GU RY aieeaa A Eea a EEE OEE a E EEEa 24 2 2 1 Cellular Connectivity Troubleshooting oooeeeeeeeenenesnnnnnneennnnnnsnsssssssssseeeerresssssssssssssseeterrereesssssssssseseetrereresssssssssseeeeerreeee 25 De COMA CCCI ON ciara ca coco tose a EE E EE E E dt sesasonbeosnsaanedoaxaraceuecateoaaes 25 2 VERIFY NGIPI CONNECTIVITY cacra a i a E a i R ienuadeeesepbanscaboeskdodedsautcmneddeesanveebices 26 23d MUMA T ECE OT a EEEE AEE E AEA EAEN EE TOEA O IEA EET E TANE EE T 28 Dil ACO ONL TES rire a E AEE ENTOTE OEE ENEO EE TA O EA EE E 29 2933 SNETI eccal SUPPI aouri aia iao r iE EEEE NNA OENE A NOAINEN NETO AEE E O AE 30 3 GATEWAY ADMI
106. 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual General Settings DMZ Host Rules Filter Rules Host Redirect Rules Masquerade Rules NAT Rules Service Access Rules Subnet Blacklist Rules Subnet Whitelist Rules General Settings Firewall The General Settings allows you to configure common access services to the Sixnet router and configure how the interfaces are interpreted Click on the General Settings menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red If9n business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Firewall General Settings Global Parameters Enable Firewall Meisner Yes MORESEE default GeeNmelaaiane MENERA Yes ITEE default ESR CE No NE MODS No E Allow Web Interface Access 4 Use Whitdist default Bee Help Note Ve eee YES TESE default Seea Allow IPSEC Allow NAT Traversal Trusted Interfaces Interface usb etho gre Interface pppo ethioo Toll Free 800 489 7 781 Sixnet Wireless P a 7 Fax 314 426 0007 4645 LaGuardia Drive aan s Web www sixnet com St Louis MO 63134 Six ais f aes Send Email to Support gt model number Copyright 2012 Sixnet Inc Enable Firewall D
107. 34 Six ne f Send Email to Support 2nd Mal model number Copyright 2012 Sixnet Inc Important Note Each type of I O must have its corresponding Object Mapping Window opened at least once or else the I O won t be mapped Be Sure to click on Save on each I O Mapping to store your configuration before moving to the next object Once all of your I O objects have been mapped move on to the next tab Default Variation Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual DNP3 Default Variation Configuration Status Admin Networking Services Advanced DNP3 Default Variation Configuration Binary Objects se paa 1 Binary input ii HE pae eee ee 2 Binary Output Status 7 Analog Objects coRE epee 1 32 Bit ki 31 Frozen Andog Input Meee cee Rte l o2 Bitwi o lime CoM seeder ve aen 32 bit wo lime 40 Analog Output Status Rae Binary Counter Objects 20 Binary Counter 9eesi hi 21 Frozen Counter Masi m repat 1 32 Bit wo lime EH prEN 1 32 Bit wo Time 7 Physical Link Layer Data Link and Application layer Object Mapping pe Toll Free 800 489 7 781 Sinet Wireless Fax 314 426 0007 4645 LaGuardia Drive i Web www sinet com St Louis MO 63134 elie 67 3 Send Email to Support 5000 gt model_number Copyright 2012 Sixnet Inc Bin
108. 4 426 0007 4645 LaGuardia Drive C i are gt Web www sixnet com St Louis MO 63134 WAXTIEC f Send Email to Support gt 70 a model_number Copyright 2012 Sixnet Inc e Click on the Display Config File menu item and the following window will appear Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Modbus Configuration Files Import Modbus Configuration File I L Browse Upload Configure Modbus Configuration File lt xml version 1 0 gt modbus subsytem modbus gt lt serials gt lt NumberOfserials gt O0 lt NumberOfserials gt lt serials gt local Station gt lt name gt RAM 6XXN lt name gt lt stationNum gt 1 lt stationNum lt localPort gt 502 lt localPort gt lt localStation gt lt Reg Allocation gt lt Analogin gt 10000 lt AnalogIn gt lt Analagout gt 10000 lt AnalogOQut gt lt DiscreteIn gt 65536 lt DiscretelIn gt lt DiscreteOut r65536 lt Discretedut gt lt Floatin gt 3000 lt FloatIn gt lt FloatoOut gt 3000 lt FloatoOut gt lt Long In gt 2000 lt Longin gt lt LongOut gt 3000 lt LongOut gt lt RegAllocation gt lt remoteStations gt Save Stop Start Refresh Download Local Remote Stations 10 Transfers Toll Free 800 489 7 781 Sixne
109. 781 Fax 314 426 0007 Wek www Jbmelectronics com WWW shomet com Copyright 2010 Sixnet LLC CONNE ONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Enable VRRP Specify whether you want to enable the VRRP service on this device The service will be started after clicking Apply and on each subsequent boot Recommended setting is Yes if you intend to setup other VRRP partners e Click on the pull down menu at the Enable VRRP field e Click on Yes and the display will expand to reveal the VRRP configuration fields Status Networking Services Advanced VRRP EG Yes Select Internal interface Use Virtual MAC Addesss ves CE O ae hf Enter VRRP Priority Enter VRRP Peer Notification interval in seconds i Sixnet Wireless Toll Free 800 489 7781 lormeriy ibm Blectronice ji Fax 314 426 0007 1645 LaGuardia Drive ka i Y Webswwwjbmetectronics com St Louis MO 63134 AL E www sixnet com Model Number Copyright 2010 Sixnet LLC Select Internal Interface Specify the interface the VRRP service should use for communication Use Virtual MAC Address Specify whether you want to allow the VRRP service to handle virtual MAC addresses Recommended setting is Yes Enter VRRP IP Address Specify the IP address of the virtual server NOTE This value must not be currently assigned to any other network interface on the subnet Furthermore this
110. 800 489 7 781 Fax 314 476 000 7 Web www sknet com Sinet Wireless 4645 LaGuardia Drive St Louis MO 63134 Send Email to Support 2nd gt model number Copyright 201 Sixnet Inc Digital Input Address Enter the address of internal IODB database for Digital Input I O control Valid Values 1 through 65535 as defined for specified I O type Digital Input Counter Counts the transitions number of changes in digital state on Digital Input Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Digital Output Address Enter the address of internal IODB database for Digital Output I O control Valid Values 1 through 65535 as defined for specified I O type Analog Input Address Enter the address of internal IODB database for Analog Input I O control Valid Values 1 through value of defined registers configured for specified I O type The address ranges are displayed on I O Transfer screen under Display Of Modbus Default Slave Addresses based on configured local register allocation for specified I O type Update Interval ms Enter update interval in milliseconds for updating the internal IODB database with value of supported IO CTRL Recommended Value 500ms or higher Enable Auto update Select Yes to enable automatic updating of the I O ports value Manual updating is dis
111. 89 7781 tor meriy ibm Electronic Fax 314 426 0007 1645 LaGuardia Drive Web www jbmetlectronics com St Louis MO 63134 WWW socnet com Model Number Copyright 2010 Sixnet LLC You will notice that two new fields Select APN Context and Enter APN The Select APN Context field has four options 1 4 these are for future implementations of carrier supplied predefined authentication parameters for SIMs installed in R3300 routers The Enter APN field is for entering the Access Point Name APN of the external Internet network that is accessible using a GSM air card To enter the username password and APN needed for GSM air cards e Click on the Enter User Name field and type in the username provided by the carrier e Click on the Enter Password field and type in the password provided by the carrier e Click on the Confirm Password field and re type the password provided by the carrier e Click on the Enter APN field and type in the APN provided by the carrier It should look similar to the following NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Cellular Connection Currently installed Modem No modem detected Enable interface CSETE Generic GSM JPA eio
112. 916 20 54 31 Kernel thi Running with NAPI enabled 20 54 31 Kernel ethi 64 64 RX TX BD ring size 20 54 31 kernel e100 Intel R PRO 100 Network Driver 3 5 23 k4 NAPI 20 54 31 Kernel 100 Copyright c 1999 2006 Intel Corporation BB Always scroll display to end Enter optional fitter sting Select of lines to display JLast250 Enable Auto update No Saan Every 15 seconds 2 Refresh Download ner lectronic Fax 314 426 0007 t645 LaGuardia Drive j Web www jbmelectronics com ss Sas St Louis MO 63134 Tr E wN www sixnet com pm E Sixnet Wireless P ai Toll Free 800 489 7781 wa i Model Number Copyright 2010 Sixnet LLC You have the option of selecting the number of lines to display enable the auto update function and set the frequency of the updates interval Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 2 11 CSQ History CSQ stands for Cellular Signal Quality The CSQ History menu item will display a listing of recent cellular signal quality It will include Module model number IMEI MDN as well as the date time CSQ ECIO and Channel information Click on CSQ History and the following screen will appear Status Admin Networking Services Advanced _CSQ History sy MC8790 352974022215602 15184664534 09724 CS50
113. A A A A E A fee a few Feer IP Address 0 0 0 0 Peguired Peer IP Port Reguired Chent IP Port Reguired Second Peer IP Address 0 0 0 0 Second Peer IP Port Second Client IP Port Third Peer IP Address 0 0 0 0 Third Peer IP Port Third Client IP Port Fourth Peer IP Address 0 0 00 Fourth Peer IP Port Fourth Client IP Port Fifth Peer IP Address 0 0 0 0 Fifth Peer IP Port Fifth Client IP Port TCP Client BroadCaster If this option is selected the device will support 10 TCP Client broadcast socket using IP Destination configuration for connectivity TCP UDP Port Configuration chee TCF Client BroadCaster Click Here To Configure IP Destination Screen TCP Client BroadCaster Traffic Activator If this option is selected the device will support 10 TCP Client broadcast socket using IP Destination configuration for connectivity and would connect only if the serial data is available to broadcast For the Broadcaster socket types you must click on Click Here to Configure IP Destination Screen to configure the host processor IP Port addresses See screen shot below for necessary information Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL 8 877 8346 a red Ibn wie 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced IP Destinations Address 1 Port 1 Connect Timeout 1 Address 2 Po
114. A OO E AEA E E E EEA E E A EE TEE OA E EAE E E E TEN 99 3 3 10 E L E E T E E E A E 100 S SIN Wy OO FN a EE EE EEE EN E EE EAEE E 103 aA Celular 16 1G 10 En ee EEEN TONTE E A TOEI ee ee ee ee RE 103 De TINS IG arracc a te neseneecaanss E ster bonent zadaseste E Me esangutecuarcsteennscheacageestenacne ancnaesstaeteecteacannestantcnetsate 117 34 3 Network CCS serra sere derceee seas eae NEN e E EEEE ENESTE EEEE EEEE ANETE A ESE NEE ESNEA AEAEE ESERE 118 EK CV EE I ETE IAT E E TEA A ENT ATEA A E EE N AN E A yews E 125 4o FPPP DO 5 121 67 01 6 ee NE EEEN E EE ANE EEE E OE EAEE OERE 152 DAO PPF aver LET siaren ea E E E EEEN E EAREN E E EEE T EERE 155 eK P PATI TROON EEE E OE EAE E E E A A EE AA E E R 157 Se TOPO SCM S rE E E E E E E EEEE 161 AA URE VNS CUE OS aaa EEEE EAEE E EE E AE E 162 33 ERE TAi E E E E E E E E 181 eye A T E A A I E S EA EAE O E AO ISI 23a DANAC DN S remmmeenerrrncr errr cent tae rere reer tener re rrtrr ener et tre Tree rerrenrr rrr terre Teeter rere rat AE 187 00 eo N ai 0 Peer re TCE eee Tre remme Teen Tee rere mere eer Tree ce mere eee ree Tere een Teen E 189 eE OV ICV IVI A E EEEE ATTAT ETTET 191 Io ae So T T a E A EE A rc neerere per errr Seretree re eee 194 Bs Soe 6 DECO O PEER ee enn PRR Pee ECE RTe EE ree ne Pre rc Pre rere ee ere et PRE ee peter Ree rene er rare Eee erer renee eee ere ere eee erent er ners rere 196 3 5 7 Client Configuration 2s ocaincdecsstrdaraiatausanizcdbisbancieias tredadadenatnesaie diese ci ciasdad
115. A a a TeS m P Enter Port 1 Enter Address 2 Enter Port 2 Enter Address 3 Enter Port 3 Host Message Format AL E a Header Type Label Enter the Lookup Key associated with this entry This is commonly a phone number or a portion of a phone number for partial matches of incoming calls i e 18 will match 1 800 xxx xxxx 1 888 1 866 and similar numbers A value of default will designate this entry as the option to use if no other entry matches If no default label exists the first entry in the list will be the default and match any incoming number received For a Dial Ring Out mode this field should match the phone number entered in the Com Port Manager configuration for Gwlnx It should also match the Gwlnx TCP Server port number if using a dynamic TCP Listening port Sixnet Inc A Red Lion Business CONNECT MONITOR CON T WJ WIV Ti OON I R JL a red Lior business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Recommended Setting 1001 for this mode AT Command Description The best choice is often determined by previous testing with a particular model brand of connecting device The first three Direct options are the most commonly used If choosing a User Defined option enter the full AT command AT Command Direct 1200 Bell212 AT amp Q6 MS B212 Direct 1200 V22 AT amp Q6 MS V22 Direct 2400 V22bis AT amp Q6 M
116. Address will be equal to the Station Number Enter Station DNP Address Enter the address for this Station if not being automatically assigned Sixnet Inc A Red Lion Business CONNECT MONITOR CO a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual Min Response Delay ms This is the time delay in milliseconds from 0 to 65535 mSec before sending the response from the slave Enable Self Address The DNP V3 00 Slave Driver can be configured to send its own DNP Address when a DNP Master asks for it When this box is checked if a message is sent with the Self Address 65532 in the destination address field the will respond with its unique individual address This feature simplifies the commissioning troubleshooting and maintenance of devices with an unknown address If this feature is not enabled the station will ignore the messages sent to the Self Address Enable Data Link Confirmation The DNP V3 00 Slave Driver can be configured to retry unconfirmed data link primary frames The number of retries the driver sends and the retry timeout are configurable This service is disabled unless Data Link Confirmation checkbox is selected The number of Retries is configurable between O Data Link Retries disabled and 255 The Retry Timeout is configurable between O0 Data Link Retries disabled and 5000ms Note The Driver s Data Link Layer will at
117. Andog Outputs F IN FX Floating Point Inputs F OUT FY Floating Point Outputs LIN LX Long Inputs Long Inputs Map I O 1 OType Description Map I O Buttons L OUT LY Long Outputs Long Outputs Map I O COUNTERS LX Binary Counters Binary Counters Map I O Physical Link layer Data Link and Application layer Defaut Variation Toll Free 800 489 7 781 Sixnet Wireless Fax 314 476 0007 4645 LaGuardia Dri a Web ixnet a lpt abuardia Unve ED WWwWW_SKneccom St Louis MO 63134 Si K r T Send Email to Support 2nd Mal model_number Copyright 2012 Sixnet Inc Define DNP Object Mapping Map I O Button When clicking on this button a new window appears This new window is used to configure and map every DNP point to a specific I O Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Object 1 Binary Inputs Define Highest Register Address No DNP Points Bee een None Exception Class Assignments Range Table Starting Register Ending Register Exception Class Assignments Physical Link layer DataLink and Application layer Object Mapping Default Variation Toll Free 800 489 7 781 Sixnet Wireless Fax 314 476 0007 4645 LaGuardia Dri be Web ixnet 404 aGuardia Dnve 2 VED WWW SENET com St Louis MO 631
118. Appendices Appendix A Refers to 3 5 10 SNMP Agent JBMELECTRONICS MIB contents The following MIBs are cellular specific It is to be noted that all of the following can be retrieved on the SN firmware version of Sixnet s routers the A M and R Series routers are dependent on the cellular module aircard installed inserted into the router Some manufacturers allow for more information to be retrieved from the module aircard than others Router Model Name unitSerialNumber STRING Serial Number of Router STRING Firmware Version Number of Router mdn STRING pin srt Mobile Directory Number the actual phone number of the device Mobile Indentification Number the number given to a service plan provided minIMEI sTRING PY the Car GN International Mobile Equipment Indentity number used by the GSM network to indentify valid devices STRING Network Access Indentifier a standard way of indentifying users who request access to a network sipUser INTEGER Session Initiation Protocol used to establish sessions between multiple parties in a location independent manner Typically voice sessions sid INTEGER sd INTEGER System ID a unique 5 digit number assigned to each carrier by the FCC nid INTEGER Network ID used to divide SIDs into smaller areas Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro
119. Cellular Connection configured as you want return to the Provisioning screen NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual If the cellular air card SIM is recognized as a supported card that can be provisioned with the Sixnet router then the following window will appear with the information about the air card SIM displayed in the upper window Cellular Provisioning ss Currently Selected Carrier Sprint Currently Selected Modem Detected ESM ESN Decimal Value Modem Manufacturer Modem Model Modem supports OMA Modem Firmware Version PRL Version Detected NAI Mobile Directory Number MON Force Provisioning Now Force PRL Update Force FUMO Update Select auto update interval Current IP Address Current RSSI Activation Status Connection Status Sierra Wireless MCS727 5089 C9A8 96 9030056 Sierra Wireless sierraMCay27 yes p2e4i4900 60750 oooo0002z792 Every 15seconds w M A 110 Running Disabled View Card Stats Log Slee ela E Mobile IP prefered Select Roaming Band preference Sync system time to cellular network time eee ee elie OMA DM Reboot Module Sixnet Wireless 4645 LaGuardia Drive St Lowis MO 62134 Gateway RS200B C Toll Free 300 4990 77581 Fax 314 476 0007 Web www sixnet com Send Email t
120. Copyright 2010 Sixnet LLC To add a GRE Tunnel e Click on the Add button and the following pop up window will appear Add GRE Tunnel Tunnel Name Enable Tunnel No Cancel ok Tunnel Name Choose the name of the interface for the GRE Tunnel Range gre1 to gre9 Enable Tunnel Click Yes to enable the tunnel and expand the display to reveal the configuration fields NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Add GRE Tunne X Tunnel Name Enable Tunnel Local IP Address Local Subnet Remote IP Address Remote Subnet Inbound Key Outbound Key Time To Live 2 Use Multicast Use ARP Start Tunnel at boot Local IP Address Set the fixed local address for tunneled packets Optional Note If supplied the Local IP Address must be an address on another interface of this host If not supplied tunneled packets can be received from any interface Local Subnet Set the local private GRE network mask Remote IP Address Set the IP Address of the remote endpoint for this tunnel Remote Subnet Set the remote private GRE network mask Inbound Key Specify a key for use with keyed GRE Key is either a number or an IP address The Inbound Key is used for input only Optional Outbound Key Specify a key
121. Discrete Out Float In Float Out Long In and Long Out The range of Modbus slave addresses are displayed based on default register allocation You can change the registers allocation values to your required register values and the range of Modbus slave addresses will be changed based on the new values By default we support 8192 DI registers 8192 DO registers 10000 Al registers 10000 AO registers 3000 LI registers 3000 LO registers 3000 FI registers and 3000 FO registers Sixnet Inc A Red Lion Business a red iar busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the Add button to configure the I O Transfer for the remote station and the following pop up window will appear Add ModBus IO Transfer Table e een tle Not Configured AeHa Mod ile ules Rapid Fire 7 Port Command Type BEE Discrete Input 7 Local Relative Address Remote Type Remote Address Number Of Registers la Enter Update Interval ms Scan Enable Type Scan Enable Address ii Station Name Name of the remote station for this I O transfer This option lists the name of all the remote stations that you have already defined and configured in remote station table entry Select the remote station name that you want for this I O transfer Protocol Modbus is currently the only supported protocol used for I O transfers Send Mode Rapid F
122. E E E N EE E E E O ESS Error Bookmark not defined GOT HS CON E O ces asses E E O E E NE Error Bookmark not defined 2003 Manace Conn ura ONS assan na o E a a Error Bookmark not defined O LPD O e a N E T A E T E Error Bookmark not defined O SS a E a E N E E T A E E Error Bookmark not defined OO O SS a E E E E E danactdeatetendeeamianssciatecaniaaes Error Bookmark not defined OM VN e aa O E E E 295 OO T E E E ose Error Bookmark not defined 5 SOFTWARE LICENSING TERMS AND CONDITIONS eeeeeeeeeeccecccecccccccceceeecececcccccesececcesececeecceececeseceseseceseseecesesesssesssesesssssse 302 FPLC COMPLANCE STAT MEN T eseeiniieiinik keniana EEEO EEE EE E E E Eed 302 INFORMA TION TO THE USER as cartsanteniorchetcin peinnsean Ta E E E Aa taint A Ei AE E ena 302 N Si xne t Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual 0 WARRANTY sscsstecsscetsccsiecesaterascechsseceieenesedscceseccielssveascuedscesesseaesusteincssedaeseensacdacsdenseuedscsunessiebeastcncestecsiuenstedvesseceualautuedeaidecedeerasedseees 303 7 APPENDICE Socorros nsee iaaa aiora a aaaea nanaii Aaaa adansoni ar aana 304 1 Accessing the Graphical Management Interface 1 1 Connect PC to Sixnet Router Connect a CAT 5 or CAT 6 Ethernet cable between the local PC and the Sixnet router s Ethernet Port s Si
123. EM_BAND from var log wireless cardstats STRING Pulls CELLMODEM_IMEI from var log wireless cardstats STRING Pulls CELLMODEM_SIM_ID from var log wireless cardstats NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346
124. ETX bytes If Payload was 296 bytes then the 2BL would be 01 2A in Hex Recommended Setting Default Allow Early Connect Only adjust this option if directed by a support technician Recommended Setting Yes e Click on the Apply button and the following pop up window will appear Operation Succeeded e Click on the OK button to acknowledge the content 3 6 6 3 Install Application The Install Application menu item allows you to install the new Gwlnx application on Sixnet IndustrialPro or R Series router devices e Click on the Advanced gt GwlInx7 Install Application menu item and the following window will appear Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced __ Gwinx Application Installation s i lt s a Select Gwinx Application File Base Toll Free 300 499 7731 py Fax 314 426 0007 Sinet Wireless Web www sienet com 4645 LaGuardia Drive Sareea iar Malo St Ours a ee Se E Aa Send Email to Support Model Number Copyright 2012 Sixnet LLC Select Gwinx Application File Click the Browse button to select a gwlnx zip file that is provided by WSBU Development Group Support staff to upload from your local system Required Recommended Setting Do not upload new files un
125. Electronios ne 4645 LaGuardia Drive r y Web www_jbmetectronics com 5 St Louis MO 63134 Wwww sixnet com Model Number Copyright 2010 Sixnet LLC Port Select the ttyS port on which the modem is attached For an external modem connected to a serial port use the port name as labeled on the router For an internal modem a common setting is ttyS3 Enter Dial String Enter the phone number of the peer ISP to dial Enter User Name Enter the name issued by you ISP used for authenticating the local system to the peer Enter Password Enter the password issued by your ISP to use for authenticating with the peer Confirm Password Re enter the password issued by your ISP to use for authenticating with the peer Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Choose Connection Behavior In Persistent mode the router will always attempt to maintain a constant connection to the POTS network In On Demand mode the connection to the POTS network will only be attempted when packets are destined to leave the modem s PPP interface In addition after a period of Idle Time the connection will terminate On Demand is commonly chosen for an environment using an Ethernet connection as a primary interface while IP Fallback is used to bring up this dialup connection as a backup e Persistent
126. Empty Port Empty Port S Empty Port 6 Empty Port Empty Port 8 Empty Port 9 Empty Port j Empty Port Empty gt Empty Sixnet Wireless Toll Free 800 489 7781 in hee 4 i Fax 314 426 0007 1645 LaGuardia Drive A nT Webwww Jbmelectronics com St Louis MO 63134 Wwww sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business NTROL 8 877 8346 a red Worn business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 151 IndustrialPro Series Router User Manual 3 2 3 Firewall Rules The Firewall Rules menu item displays a complete listing of the rules used within the firewall for the Sixnet router If you are familiar with Linux and IPTABLES then this will of great use to you Networking Services Advanced Firewall Rules Firewall Enabled Yes Firewall On Yes Firewall Active Yes Chain INPUT policy DROP O packets O Hytesi at pets bytes target prot opt in out destination 64 4351 ACCEPT all lo O 0 0 0 J E DROF top pppo 070 D DROP tep etht O 0 DROP udp etht O 0 DROP top eth 070 DROP udp etht O 0 Sc aN tep ppp 0O70 SCAM tep pepo O 0 FLAGS tep pepo O 0 FLAGS cep pppo 070 FLAGS tep pepo O 0 FLAGS tep ppp O 0 FLAGS tep pppo 070 FLAGS ppp O 0 LOG pepo O 0 DROP pppo 070 ACCEPT pppo o d ACCEPT ipsect e070 a mm mm Lo a m S m S m S m S m S m S oon m S ma S m D m D m O m G m G 4 4 4 4 4 4 H Ht
127. Enable SSL hi Toll Free 800 489 7 781 Sixnet Wireless Fax 314 476 0007 4645 LaGuardia Drive ie Web www sixnet com St Louis MO 63134 Si xne f Send Email to Support 5200 Mal model_ number Copyright 2012 Sixnet Inc e Click on the pull down menu at the Enable SSL e Click on Yes and the display will expand to reveal the configuration fields Status Networking Advanced SSL Client 55L Client Stopped JENGENE Yes Activity Log Levd Wat for Connection sec Idle Timeout min PAi Advance Setup No Label TCP Listening IP TCP Listening Port SSL Destination IP SSL Destinatia Toll Free 800 489 7781 Sixnet Wireless Fax 314 476 0007 4645 LaGuardia Drive a pr Web ixnet AD WWW s Xnet com St Louis MO 63134 S IX ne Send Email to Support 5200 Mal model number Copyright 2012 Sixnet Inc Activity Log Level This controls the logging level for SSL Connection activity Recommended setting is Summary for a production and Full for test environment Wait for Connection sec Time in seconds allowed after sending SYN packets to wait for SYN ACK Default is 20 NU Sixnet Inc A Red Lion Business COI NITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Idle Timeout min Time in minutes allowed for no traffic over an SSL c
128. Enabling TCP Keep alives may dramatically increase the total amount of traffic for the affected socket s depending on the master interval probe and timeout settings which should be considered for connections using a wireless cellular connection with respect to total data usage for the subscripted plan Add SSL Client Interface e Click on the Add button and the following pop up window will appear Add SSL Client Interface Label TCP Listening IP TCP Listening Port fF SSL Destination Port Label Enter a unique name to describe this connection TCP Listening IP Enter the IP to listen on for incoming connections If not using static IP addresses it is recommended to use the Advanced Setup option Bind Interface for accepting TCP Connections instead Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Leave blank 0 0 0 0 to allow connections from any interface Use 127 0 0 1 for internal connection use only gwlinx Protocol Converter TCP Listening Port Enter the listening port for this connection Please note that this port must be allowed in the Firewall access rules for any external untrusted interface It may be helpful to review the results of Status gt Socket Statuses gt TCP Only to confirm that your choice of listening port is not already in use Po
129. Interface Select the name of the Ethernet interface to which the PPP over Ethernet service should bind by choosing one of the options available in the provided drop down list Choose eth0O or eth1 Enter User Name Enter the user name to be used with the PPPoE interface in the space provided It is typically in the form name domain com Enter Password Enter the password to be used with the PPPoE interface in the space provided Confirm Password Re enter the password to be used with the PPPoE interface in the space provided Select DNS Method Select the method by which DNS Server information should be obtained Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Use Unit Default e Donot obtain DNS information from PPPoE Server Use settings from Networking DNS Settings instead Use Peer DNS e DNS information should be obtained from the peer host once connected Use Custom DNS e DNS information is entered manually in the fields which appear below i AGel bee nem Use custom DNS gt Enter Primary ONS Server Address JP Enter Secondary DNS Server Address e Enter the IP Addresses of the Primary and Secondary DNS servers to be used Use Default Route Select Yes to use this interface as the default route Dial on Demand Select Yes to enable Dial on
130. LC e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says eS GMU Client settings applied e Click on the OK button to acknowledge the content 3 5 5 SSH Server The SSH Server menu item allows you to configure whether the Sixnet router will communicate with the network via Secure Shell SSH Click on the SSH Server menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced SSH Server Enable SSH Server No Sixnet Wireless Toll Free 800 489 7781 P Fao 314 426 0007 for tw jon ee ire gt 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC Web www jbdmelectronics com www sixnet com Click on the pull down at the Enable SSH Server and the display will expand to reveal the configuration fields shown below Status Networking Services Advanced SSH Server Enable SSH Server ves Configure Advanced SSH Parameters Yes z Listening IP Address For SSH Listening IP Port For SSH SSH Protocol Version Version2 Login Grace Time in seconds Maximum Concurrent Connections ho Allow Root Login Toll Free 800 489 7 781 Fax
131. Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 3 10 System Time The System Time menu item allows you to configure the Time Zone on the Sixnet router to correspond to your location e Click on the System Time menu item and the following window will appear Status Networking Services Advanced System Time Time Zone Tepes Current System Date MMIDDIVYYY joa E he f 2mo Current System Time HHMM 53 fo ss 24 Syne to NTP Server No z Use Local System Time 4 16 2010 20 41 35 Sixnet Wireless for marly jbm Blectrorec 4645 LaGuardia Drive St Louis MO 63134 Model Number Cancel Apply P a Toll Free 800 489 7781 Fax 314 426 0007 Web wwwJjbmetectronics com WWW sixnet com Copyright 2010 Sixnet LLC e To change the Time Zone click on the pull down menu next on the Time Zone field The following is a full list of available Time Zones CET Universal Moscow Europe CST6CDT W SU Nicosia Europe Cuba WET Oslo Europe EET Zulu Paris Europe EST Atlantic Canada Prague Europe ESTS5EDT Central Canada Riga Europe Egypt East Saskatchewan Canada Rome Europe Eire Eastern Canada Samara Europe Factory Mountain Canada San Marino Europe GB Newfoundland Canada Sarajevo Europe GB Eire Pacific Canada Simferopol Eu
132. NAT One To One Rules New Dest Addr Protocol Source Whitelist 10 100 100 25 TCP default Orig Dest Addr 205 35 42 235 Orig Dest Addr Start Orig Dest Addr End New Dest Addr Start Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 model_number Click on the Save button and the following pop up window will appear Firewall settings saved Services Advanced Delete New Dest Toll Free 800 489 7781 Fax 314 426 0007 Web www sixnet com Send Email to Support Copyright 2012 Sixnet Inc The page at http lt IP Address gt 10000 says SEE OO O e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear NU Sixnet a red lon business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content To add a new NAT One To One rule e Click on the Add button and the following pop up window will appear Add NAT Range Rule Original Destination Address Start New Destination Address End Select Protocol CF See eee ae detault Original Destination Address Start This field is
133. NECT MONITOR CON a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 877 8346 IndustrialPro Series Router User Manual Keep Alive Behavior This option enables TCP Keep alives on the underlying sockets The following options are supported None Keep alives not used All Keep alives enabled for all sockets Accept Keep alives enabled for listening server socket side connections only This applies to the clear text server for Client mode sockets or the SSL Encrypted server for Server mode sockets Remote Keep alives enabled for client initiated sockets Local Keep alives enabled for client connections bound to a local IP address You may need to adjust the master Keep alive timer via Networking TCP Keep alives NOTE Enabling TCP Keep alives may dramatically increase the total amount of traffic for the affected socket s depending on the master interval probe and timeout settings which should be considered for connections using a wireless cellular connection with respect to total data usage for the subscripted plan Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Hon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Server Configuration e Click on the Add button and the following pop up window will appear Add SSL Server Interface Label SSL Listening IP SSL List
134. NISTRA TION UTILITY siscccccssssseshsonesisoancseesdonceseonnnndodosanacbsonaaneenban iaiia aeaiaioii 31 3 1 GATEWAY ADMINISTRATION UTILITY GAU INTRODUCTION cccccccccesccceseccceccceseccenecceecceuececenecceeceeueceeecesenceseneseeeceeeecenes 31 Se OPO ess civic sewn tessg gen a snes ees acca ean ges ern user gaeeanwsasenanen aaeen E E E E E SE S 3 edi BSCE aerate cites cists cacterna no saa cits E A A dates A A E EE 32 T A crease ofc ore sans alata a de ten cision ope cates att oe wa dated elon AA ete w ates A A E AEA 33 ed ACTIV OV 1S icra strstucten auc cs E een ous sinaluson axigu plow EE a dan seve ction E A EE E EE A E E anaes euteenoases 34 A PRCT VI COG serraties cre lrg cts E NPE AN E suis tenia saecoaa E A E E A E E AA 35 P AT T EE EE EEEE EEE E EE a nete aaemacwnenemaneton re 37 LA ATC ene E TT TEEN TET De SED ENTREE rT Neer ern TREE Mer Err erTre Tern eT eer MTree ner ter cra err rrr arr Terr met errttce 38 De COT COS esses cece ce ces cck cass ansce E EA oes aa eda 0 sade cae ease ae ene eee 39 fo re A E eRe CE EOE PERRET EET HET VET EET ETE ET TESTE TTT SET TERETE Tree CT EE nT TETTEE E 40 JaA 1 12 OLGA Mormia 0 eee ERP CET ER REECE iea CTE RTE Trt Tare TET MT CERET Mre rere Terre ee ere ST ainaani 4 323 KONE IOMON eC RT EER ECP RPE CET CC RC i ET eTEC OTT ErE Taree Tete ETC Eret Mtr ree rt a rrr err err ee retreat errr 45 DDO SOCK 11S etic areca seicdrcnerpcp sero E A este ovo earn sistred sa dat od deve eteed ve E A noise
135. New Destination Address Start and New Destination Address End fields Both fields can be any valid IP Neither need to be already present configured owned on a local interface of this device Required NOTE Host Redirect and Service Access rules will apply first and may prevent certain ports from reaching the New Destination Ports 1 19 are excluded Click on the NAT Rules menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Firewall Orig Dest Addr New Dest Addr Protocol Source Whitelist reren Orig Dest Addr Start Orig Dest Addr End _Cancel Save Apply Sinet Wireless 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7 781 Fax 314 476 0007 Web www siknet com Send Email to Support model number Copyright 2012 Sixnet Inc To add a new NAT One To One rule Click on the Add button and the following pop up window will appear ZN Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Add NAT One To One Rule Origina Destination Address New Destina
136. Number MDN Force Provisioning Now Force PRL Update BB View Card Stats Log Sixnet Wireless P Toll Free 800 489 7781 formaro lien Glantrovics Fax 314 426 0007 4645 LaGuardia Drive Web www jbinelectronics com St Louis MO 63134 www sboet com Model Number Copyright 2010 Sixnet LLC e Under the Networking tab highlight Cellular Connection and choose the Configuration option NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Configuration ONS Settings Instal F irr PPP Dial Backup PPP over Ethernet static Routes TCP Global Setings Phy Ethernet Interface Connection State etho Up eth Up IP Address f2 701 201 31 Cellular Interface Activation Connection pppo ed Enabled ae aie Disabled Sixnet Wireless formerly jbm Electronics 4645 LaGuardia Drive 5t Louis MO 63134 Model Number Services Provisioning IP Address Advanced Link Status E E Signal Strength EVDO REV A 7 Toll Free 800 489 7781 Fax 314 476 0007 Web www jbmelectronics com WWW Sixnet com Copyright 2010 Sixnet LLC e Instructions for Cellular Connection configuration are located in the previous section beneath the Configuration heading e Once you have the
137. O 63134 Send Email to Support 52nd Mal model number Copyright 2012 Sixnet Inc Sixnet Inc A Red Lion Business CONNEC ONITOR COI NU red in vusiness 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Click on the I O Transfer menu item and the following window will appear Status Admin Networking Services Advanced _ ModBus IO Transfer lt 2 Registers Allocation Analog In El Analog Out Long In 4 F Long Out Float In 3 Float Out Type Modbus Address Range Display Discrete Input 1 1 65536 17000012 1 65536 1 65536 O 00001 0 65536 1 10000 S 00001 3 10000 1 10000 4 00001 4 10000 10001 13000 S 10001 3 13000 10001 13000 4 10001 4 13000 13001 16000 3 15001 3 16000 13001 16000 4 15001 4 16000 So Discrete Output Analog Input Analog Output Long Input Long Output Float Input Float Output e W e WU amp Li 10 Transfer Table Properties Station Name Protocol Send Mode Port Command Type Local Type Lo Local Remote Stations Forwards Serials Display Config Files _ Toll Free 800 489 7761 Fax 314 426 0007 Sixnet Wireless a Web www sixnet com 4645 LaGuardia Drive EL 2b E h E Send Email to Support 5en0d Mail BT 6821 HSPA Copyright 2012 Sixnet Inc Register Allocation This page is displaying the default values for Analog In Analog Out Discrete In
138. P Address gt 10000 says Save operation succeeded e Click on the OK button to acknowledge the content e Click on the Apply button and the following warning pop up will appear The page at http lt IP Address gt 10000 says If you are currently connected to the Gateway Administration Utility through this interface applying new route settings will require restarting the affected interfaces which may result in result in disconnection and you wil have to reconnect using the new settings Incomplete or incorrect network settings could render the device incommunicable Are you sure you want to proceed C e Click on the OK button to acknowledge the content e Click on the OK button and the following pop up window will appear N Sixnet a red Hon business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 Toll Free 800 489 7 781 Fax 314 476 0007 Webowwwijbmetectronics com WWW sixnet com Copyright 2010 Sixnet LLC CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The page at http lt IP Address gt 10000 says Operation Succeeded Ea PE e Click on the OK button to acknowledge the content 3 4 8 TCP Global Settings Click on the TCP Global Settings menu item and the following window will appear Status Admin Networking Services Advanced __TCP Global Settings
139. S V22B Direct2 1200 Bell212 AT NO MS B212 Direct2 1200 V22 AT NO MS V22 Direct2 2400 V22bis AT NO MS V22B ErrorC 1200 Bell212 AT N3 MS B212 ErrorC 1200 V22 AT N3 MS V22 ErrorC 2400 V22bis AT N3 MS V22B Recommended Setting Direct 1200 Bell212 AT amp Q6 MS B212 Answer Dial Mode For incoming calls choose ANSWER_2WAY_RAW For outbound Ring Out Ring Down mode choose DIAL The other options should only be used if instructed to do so by a support technician Recommended Setting ANSWER_2WAY_RAW Message Mode This will choose between enabling the local Visa protocol engine or allowing Passthru Transparent mode Transparent Allow raw communication between the Dial port and the TCP Connection Visa Enable local Visa engine This will process one transaction and issue an EOT after the transaction response has been sent to the dial device Visa2 Enable local Visa Il engine After a transaction is complete an ENQ will be issued to query the next transaction in sequence If there is no response to the ENQ then an EOT is issued Recommended Setting Transparent Timer Timer usage in supported Message Mode Transparent Mode This is the inter character delay in milliseconds used on the serial side to determine when a remote device is finished transmitting A low value may generate a faster response but can send many TCP packets and NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red
140. SEC ves Enable NAT Traversal No Coordinate IPSec with Yireless PPP On sla IPSec Restart On eis IPSec Stop Coordinate IPSec with PPPoE On LAR PSec Restart z On Meru PSecStop SO it aot aa eo een IPSec Restan ESiseiieuucial iPoecSiop gt IPSEC Tunnels Name Enable Local Public Local Private Remote Public RemoteP Add _ jbmtest Yes 10 100 100 0 24 10 100 200 024 2056536194 1010100 Cancel f Save Apply _ Sixnet Wireless 5 Toll Free 800 489 7781 tormeriy ibm Electronios Fax 314 426 0007 1645 LaGuardia Drive Web www jbmelectronics com St Louts MO 63134 www sixnel com Modet Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Save operation succeeded e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Operation Succeeded e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual IPSEC Status The IPSEC Status menu item allows you to display the current connection status of the VPN Tunnel by name and subnet
141. SN Sb5bci4 Modem Manufacturer Novatel Vdreless Inc Modem Model E725 SPRINT Modem supports OMA no Modem Firmware Version MS00A RAPTOR_SPRINT 145 Apr 03 2007 17 12 43 PRL Version 20227 Detected NAI sixnei0001 springpes corn Mobile Directory Number MDN 2345434352 Force Provisioning Now Force PRL Upda BB View Card Stats Log Soe GCs Mobile IP prefered Sync system time to cellular network time SPC Unlock code OoOo ESN Select type of provisioning MIN SIC Sixnet Wireless s Toll Free 800 489 7781 SAS ee pra ee Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 Www sbcnet com Model Number Copyright 2010 Sixnet LLC e Enter your ESN also show at the top in HEX format e Choose your provisioning type Select Vision IP Only for standard activation e Enter your SPC Unlock code MDN and MSID Click Apply e For non OMA capable devices you should also click the Force Provisioning Now button e For installations using the R3200 A2200 M1200 series a reboot may be required which will happen automatically if necessary e R Series Observe the RSSI status lights on the front of the router Within a minute you will see the lights blinking in an upward fashion This indicates that activation is taking place e R Series Once activation is successful the lights will return to a signal strength indication Lights will flicker slightly every 2 seconds wh
142. Series Router User Manual Preferred Roaming List a list of information that resides in the memory of the module aircard It lists the radio frequencies the module aircard can use in various geographic areas The part of the list for each area is ordered by the bands the module aircard should try to use first Therefore it s a kind of priority list for which towers the prl INTEGER module aircard should use The PRL helps determine which home network towers to use and also which towers belonging to other networks to use in roaming situations areas where the home network has no coverage When roaming the PRL may instruct the module aircard to use the network with the best roaming rate for the carrier rather than the one with the strongest signal at the moment Since a PRL tells the module aircard where to search for a signal as carrier networks change over time an updated PRL may be required for a module aircard to see all of the coverage that it should both with the home network and for roaming Determines if the module aircard is authorized onto the carrier s network activated INTEGER Values are Unknown 1 No 0 Yes 1 Open Mobile Alliance for Device Management OMA DM designed for management of small mobile devices such as mobile phones PDAs and palm top computers The device management is intended to support the following typical uses Provisioning Configuration of the device including first time use enabling
143. Sixnet com Sixnet Wireless 46 15 LaGuar dia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC Click on the Upload button The following pop up window will appear to show the file was successfully uploaded NU CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 IndustrialPro Series Router User Manual EN The page at http lt IP Address gt 10000 says SS File upload completed successfully e Click on the OK button to acknowledge the content e The Import button is now available Status Admin Networking Services Advanced Export GAU Master Configuration File Import GAU Master Confiquration File Default Import file handling Select GAU Master Configuration File C Documents and Settings mohammad My Documents Downloads contig xml txt U pload Save import file without applying changes M Import Sixnet Wireless Toll Free 800 489 7781 4645 LaGuardia Drive s Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copyright 2010 Sixnet LLC e Click on the Import button to reload the system configuration file Note If you want to save the new configuration without immediately applying it simply check the box provided next to Import button Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 120
144. Status Admin Networking Services Advanced IP Fallback IP Transparency Installed Firmware Version ae Out otBand lgt Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address Link Status ethd Up 192 168 0 1 Up eth Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength ppp z Enabled 72 701 201 31 EYDO REW A Fi Sixnet Wireless E Toll Free 800 489 7781 for merly j bm Electronics ae Fax 314 426 0007 4645 LaGuardia Drive a F T i Web www jbmelectronics com St Louis MO 63134 of ir WWw sixnet com Model Number Copyright 2010 Sixnet LLC 3 6 5 1 Configure Sub systems The Configure Sub systems menu item allows you to edit the main configuration files of the Sixnet router Again it is not recommended that you perform configuration activities using this facility unless instructed to do so by Sixnet Technical Support Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced IP Fallback IP Transparency Installed Firmware Version Out of Band Mgt Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address Link Sta
145. T MONITOR CONTROL 3 red Irn busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Filter Configuration This menu item allows you to set the filter values in similar format as the TCPDUMP filter for capturing traffic being seen by configured device on the Ethernet port Note This configuration screen is for devices that capture traffic between the ATM and transaction processing server for DVR text insertion Please contact WSBU Development Group Support staff for configuring this item e Click on the Add button and the following pop up window will appear Add Filter Settings Spee stele eee 92 168 10 100 Enter TCP Port H001 IP Address ATM Enter the IP address of the ATM that you would want to sniff from the network traffic Not Required TCP Port Enter the destination port address that the ATM connects to for processing transactions which will be used as a filter to sniff network traffic Required e Click on the OK button to populate the Filter Settings screen e Click on the Apply button and the following pop up window will appear Apply Operation Succeeded e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router
146. TROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Enter Client MAC Address Description Enter the Client s computer or device MAC address Client MAC Address The Media Access Control MAC address is a unique number assigned by the manufacturer to any Ethernet networking device such as a network adapter that allows the network to identify it at the hardware level For all practical purposes this number is usually permanent Unlike IP addresses which can change every time a computer logs on to the network the MAC address of a device stays the same making it a valuable hardware identifier for the network When entering the MAC address information type the 12 digit MAC address in the following format XX XX XX XX XX XX Including the hyphens Enter Client IP Address Description Enter the IP address for which you wish to assign to a client s computer or device MAC address Client IP Address An address valid for the subnet for which the interface is configured Care should be used to ensure that there is no conflict with any pre existing devices on that subnet which may have been already configured to use statically assigned IP addresses Recommended Setting This address should have been provided by your Network Administrator e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt
147. The Maximum Receive Idle Time Enter the number of seconds the connection may be allowed to remain idle or unresponsive no data received before closing the connection If packets are leaving the interface but no return packet is received for the specified time then the connection is reset This can be useful for detecting an unresponsive situation where the network is down the modem is in an unknown state or other low level error may have occurred Recommended times are O seconds to turn off or 150 seconds 2 5 minutes This is defaulted to 150 seconds To change the value e Click on the box for Maximum Receive Idle Time e Input the time to fit your needs Use Default Route This field allows you to choose to have the default route for the Sixnet router to be the cellular connection when it is connected or to designate an Ethernet port as the default route The default setting is Yes To change the setting e Click on the drop down menu at the Use Default Route field e Click on the No selection Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Use Peer DNS This field allows you to choose whether the Sixnet router accepts DNS information from the peer device to which it is connected or uses DNS servers designated on the DNS Settings p
148. Time Synchronization from the DNP V3 00 Master Requests can be configured to be made at intervals of once per minute once per hour once per day or never Click Save to save your configuration and move on to the next tab Physical Link Layer Navigation buttons across the bottom of the DNP3 screen match the selections made from the drop down tab menu e xq Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Physical Link Layer Status Admin Networking Services Advanced DNP3 Physical Link Configuration Physical Link Layer Mode of Operation E Seria TCP E UDP TCP UDP Mode E Client Server TCP UDP Port Default 20000 FAGUL Required Data Link and Application layer Object Mapping Default Variation _ Cancel Save Apply Toll Free 800 489 7 781 Socnet Wireless Fax 314 436 0007 4645 LaGuardia Drive ee Web www spnet com St Louis MO 63134 Six ie T Send Email to Support 5200 Mal model_number Copyright 2012 Sixnet Inc Mode of Operation The DNP V3 00 Slave Driver implementation supports RS 232 and RS 485 two and four wires over serial port communications as well as TCP IP and UDP IP over LAN WAN communications When the user selects the Serial Mode the TCP UDP section is disabled The same happens to the Serial section if the Mode of Oper
149. U PMTU Discovery Enable Disable Path MTU Discovery This might be useful if a private cellular network is restricting MTU sizes along the network path and causing packet drops e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Operation Succeeded e Click on the OK button to acknowledge the content 3 4 9 Tunnel VPN Settings The Tunnel VPN Settings menu item is organized into three sub sections GRE IP in IP and IPSEC GRE Tunnels Generic Routing Encapsulation The GRE Tunnels menu item allows you to configure a GRE Tunnel GRE is a tunneling protocol that was originally developed by Cisco it can do a few more things than IP in IP tunneling For example you can also transport multicast traffic and IPv6 through a GRE tunnel Click on the GRE Tunnels menu item and the following window will appear N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced GRE Name Enabled LocaliP Local Subnet Remote IP Remote Subnet Sixnet Wireless loll Free 800 489 7781 toe merly jbm Elecirorii Fax 314 476 000 7 46451 aGuar dia Drive Webk www Jbmelectronics com St Louis MO 63134 www sbmet com Model Number
150. VDO REV A eRe Disabled b P Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics aTh es Fax 314 426 0007 4645 LaGuardia Drive w i a Pim Web www jbmelectronics com St Louis MO 63134 he TF FiF WWW sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the IP Fallback menu item and the following window will appear Status Admin Networking Services Advanced IP Fallback Automatic Default Route Failover Settings Enable iP Fallback No Sixnet Wireless p Tol Free 900 489 7781 Kai Fax 314 476 0007 or merty Leis 4645 LaGua Aa Webswww jbmelectronics com St Louis MO 63134 Ta a aiis www sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down at the Enable IP Fallback field e Click on Yes and the display will expand to reveal the IP Fallback configuration fields Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced IP Fallback Automatic Default Route Fallover Settings Enable IP Fallback ves Select Primary interlace eyes Select Primary Extarnal Command Script Select Secondary interface jeno Select Secondary Extemal Command Script Enter Primary Test iP Address _ eine Erder Request interval in seconds Test Packets
151. Web www jbmelectronics com St Louis MO 63134 fi sae Pa amp WWW sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CON MONITOR CON a red Lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 877 8346 IndustrialPro Series Router User Manual e Click on the Standard Routing Table menu item and the following window will appear Status i Networking Services Advanced Kernel IF routing table Destination Gateway Ama LRS o LEH ls 0 0 0 0 192 168 1 0 192 165 0 0 27 0 8 8 Itac pppo ethl etho lo pppo Metric Ret m E Gl Ln m m D 1 I m in in Da pa m n Q U in t I c LY CI CI E Statically Defined Routes Sixnet Wireless r Toll Free 800 489 7781 formerly jbm Electronics i b he Fax 314 426 0007 4645 LaGuardia Drive b yr aT Web www jbmelectronics com St Louis MO 63134 a eke eS WWW sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 2 6 Socket Statuses Sockets are end points to communication over the Internet Much like PBX phone systems where the IP address is the phone number and the port is the extension Every paired connected socket has a source IP port and a destination IP port The Socket Statuses
152. X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL m red lor business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual PWR i j GND OUT IN Diversity ye Antenna i WT ey www sixnetLcom ang 2 ACA rece Ethernet RS232 SN 6601 voo Power WAN AN l Ta A l gt AN RS232 Signal r F P s gt s f 3 gt 2 www sixnet com Power WAN eS eee cabs NOTE If the Ethernet port s Green light is lit this indicates that the connection is running at 100Mb speed If the Ethernet port s Green light is not lit this indicates that the connection is running at 10Mb speed The Yellow light indicates the link status of the connection Yellow steady Link established Yellow flickering Data packets are being transferred 1 2 Setup PC IP Address 1 2 1 Open the Control Panel e Click on Start and browse the Control Panel menu item XP Sixnet Inc A Red Lion Business CO _CONTF a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual Ze Microsoft office visio 2007 ve Control Panel Ss Printers and Faxes 9 Help and Support Pp Adobe Reader 9 Set Program Access and Defaults All Programs gt A Log Off Turn OFF Computer Vista Windows 7 i Windows Photo Gallery
153. a ratio of good to bad energy representing the cell towers cleanness in its signal to you In other words signal to noise ratio INTEGER Current Received Signal Strength Indication currentEcio INTEGER Ec lo is a ratio of good to bad energy representing the cell towers cleanness in its signal to you In other words signal to noise ratio GSM which stands for Global System for Mobile communications reigns as svcType STRING the world s most widely used cell phone technology CDMA or Code Division Multiple Access uses a spread spectrum technique whereby electromagnetic energy is spread to allow for a signal with a wider bandwidth This allows multiple people on multiple cell phones to be multiplexed over the same channel to share a bandwidth of frequencies currentChannel INTEGER Channels are used to different frequency range network to operate on the same frequency in the same area that do not interfere with each other cdmaType STRING _ _ None Analog Digital High Data Rate type normally Digital hdrType STRING Unknown None RevO RevA The CDMA EV DO sub type cdmaRoaming STRING Home Roaming Roaming unknown Roaming type indicator insoide or outside the providers home network hdrRoaming STRING SODE Roaming SIDS Guaranteed Roaming SIDS Not Guaranteed EV DO Roaming state Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road
154. able SNProxy Settings id Use HTTPS SSL Encryption Use HTTP login No ha Listen Port o Required soniga 192 168 0 1 Required rd Teen 20000 Required Vi Toll Free 800 489 7 781 Sinet Wireless Fax 314 4276 0007 4645 LaGuardia Drive 5 G he s t Web WAU WAU A Si el a j z L n zj L1 St Lou i F MO o gt 34 Si X i eC con Send Email to Support 50n Mal model number Copyright 2012 Sixnet Inc Use HTTPS SSL Encryption Specify whether you want to enable the SSL engine Use HTTP login Specify whether you want to enable HTTP login Note If you enable the HTTP login you will be required to enter the username and password Listen Port Enter the port number the SNProxy listens for requests on Host IP Enter the proxy server host IP address that will be accepting this connection request Host Port Enter the proxy server host port number e Click Save to store the settings for the next reboot or click Apply for the settings to take effect immediately Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 5 4 SixView Manager The SixView Manager menu item allows you to configure various aspects of the SixView Manager Client to communicate with a SixView Manager hosted at Sixnet or at your location e Click on the SixView Manager menu item and
155. abled while auto update is in effect Recommended Setting Yes Select update interval Select the update interval to be used when auto update is enabled from one of the choices in the drop down list provided Choices in seconds include 3 5 10 15 Be advised that when connected via a Cellular interface the data collected will count towards your total data plan usage Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 5 13 DNP3 DNP3 functionality will be available in SN Firmware Version 3 13 DNP3 Distributed Network Protocol is a set of communications protocols used between components in process automation systems Its main use is in utilities such as electric and water companies Usage in other industries is not common It was developed for communications between various types of data acquisition and control equipment Status Admin Networking device_family Administra Installed Firmware Ver firmware revision Device Senal Numbe serial number System Uptime OD OH 11M 85 Advanced Dynamic DNS SN Proxy Settings SixView Manager GPS Settings SSH Server System Logging TELNET Server Ping Alive Physical Interface Stat sy mp agent Connection State IP Up Up Ethernet Interface usb etho Cellular Interface Activation N A Reg Ho
156. age listed in the next section The default setting is Yes To change the settings e Click on the pull down menu at the Use Peer DNS field e Click on the No selection Enable Dial Holdoff The Dial Holdoff behavior will restrict your connection to three 3 failed connection attempts before entering an idle state for a duration of time specified by the Dial Holdoff Timeout parameter The default setting is No To change the settings e Click on the pull down menu at the Enable Dial Holdoff field e Click on the Yes selection a new field will appear select Dial Holdoff Timeout PELE 30 Minutes 45 Minutes 60 Minutes These are the holdoff timer settings To change the settings e Click on the pull down menu at the Select Dial Holdoff Timeout field e Click on the selection you want Choices are 15 Minutes 30 Minutes 45 Minutes and 60 Minutes Once you have the Cellular Connection configured as you want e Click on the Apply button to accept the changes Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Provisioning The Provisioning menu item allows you to activate a limited number of cellular air cards for a limited number of carriers Status Admin Networking Services Advanced Configuratio
157. age of the GAU screen and observe if the Cellular Interface status shows an IP Address On the Home screen you should see Interface Activation Connection IP Address and Signal Strength If you do not see an IP Address get populated for the PPP interface you may have an issue with your settings or your account has not been correctly activated 2 1 1 Cellular Carrier Selection Status Admin Networking Services Advanced Cellular Connection Currently Installed Modem Sierra Wireless MC8790 MC8795 E ie YES Select Celular Carrier Enter User Name oo Enter Password oo Confirm Password fT ts iS Y Select APN Context Enter APN a APN for context 1 is aon pn af me TE ou ERCA Siera Wireless MC6 OO MCG amp 95 Enable Modem Auto Detection View Change Advanced Options No Toll Free 800 489 7781 Fax 314 426 0007 Sinet Wireless Web www sRknet com 4645 LaGuardia Drive St Louis MO 63134 Send Email to Support 520d Mal model number Copyright 2012 Sixnet Inc e Select Yes to enable the interface to become active after the new settings are applied and upon subsequent system start up e Optionally you may select the cellular carrier you are using from the drop down menu Currently this will not change operation and may be auto detected Generic CDMA and Generic GSM will allow options to cover all known carriers e Select the name of the provider of your cellular wireless data plan from the
158. al If the interface was already active then it will be deactivated and reactivated using the configured settings just saved If you were connected to the GAU via this interface an attempt will be made to re connect to it using the new settings when possible Note 2 Applying new settings to the interface may result in disconnection requiring reconnection using alternate methods Incomplete or incorrect network settings could render the device incommunicable and may require being able to connect either to the device directly or via the network to which it is attached Interface Speed Duplex This configuration parameter controls the speed and duplex behavior of the Ethernet port Valid selections are e Auto Detect The Ethernet port will attempt to automatically determine both the speed and the duplex settings of the device to which it is connected Some devices to which Sixnet routers are connected do not always perform proper speed and duplex negotiation In the event that throughput and performance difficulties are encountered it is recommended that speed and duplex of both the Sixnet router and the device to which it is connected have the speed and duplex configuration explicitly specified e 10Mbps Half If selected the interface will communicate at 10 million bits per second and half duplex meaning that one side will communicate while the other one listens e 100Mbps Half If selected the interface will communicate at 100 million bi
159. all Firewall iptables FTP Server GPS Control GPS Mode IP Fallback IP sysctl IGMP Proxy Daemon Interface ethO Interface eth1 Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IPRoute2 ematch IPRoute2 realms IPSEC Configuration Init Modbus Config NTP Daemon Open VPN server PAP Secrets PPP Options PPPDial IPSec Ping Alive Conf 1 SDK SN Proxy Daemon SSL Tunnels client System Logging VRRP Daemon Instance 2 Zyxel Configuration Status IndustrialPro Series Router User Manual IPRoute2 dsfield IPRoute2 scopes IPSEC Secrets Lighttpd Conf Mrouted multicast Out of Band Open VPN Authpass PPP IP DOWN PPPoE PPPoE IPSec Ping Alive Conf 2 SMCroute Daemon Multicast SSH Client Configuration SSL Tunnels server System Start up Wireless Provisioning Networking Expert Mode IPRoute2 protos IPRoute2 tables GWLNX Control Lighttpd User Modprobe conf Open VPN client OSPF Daemon PPP IP UP PPP IPSec PIM Daemon Multicast RIP Daemon v2 SNMP Daemon SSH Server Configuration Static Routes VRRP Daemon Zebra Services Advanced Ses seen IPSEC Configuration version 2 0 basic configuration contig setup plutodebug klipsdebug all conforms to second version of ipsec cont specification none or a combation from below raw crypt parsing emitting control
160. allocations When disabled all switch ports 1 5 will be treated as a single LAN This will be configurable as ethO and will default to being a firewall trusted internal interface When enabled port 5 will be divided out as a WAN port ethO firewalled as external untrusted Ports 1 4 will be an internally trusted LAN WARNING When switching modes your firewall interface tables will be rebuilt and may need any custom changes reapplied In addition a USER INITIATED reboot is required to complete the mode switch WARNING When enabling switch mode current Ethernet settings eth0 will apply only to the single WAN port On the front of the unit this may be shown as lt Port 5 gt under the power connector The remaining four ports will be configured as a LAN eth1 Please check your Ethernet connections to make sure that the new settings will not conflict with previous network configurations You may need to revisit your Untrusted Trusted interface lists in the Firewall gt General Settings as these will revert to new defaults ethO will be firewalled as Untrusted After an Apply is performed and you check firewall ethernet configurations a reboot is REQUIRED to complete this process 3 4 4 Firewall The Firewall menu item allows you to configure every aspect of the firewall on the Sixnet router It is organized into nine 9 sub sections N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business
161. allston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual NOTE When changing the Primary Address to your own private SixView Manager server you may want to consider setting the Secondary Address to the Sixnet SixView Manager test server www mygmu com for trial and initial production rollouts This will enable Sixnet support staff to monitor the progress and better assist in diagnosing potential problems Select Primary Alternate Connection Mode Select the desired Connection Mode from the provided drop down Primary Only The SixView Manager client only connects to the Primary Server Secondary OnlyThe SixView Manager client only connects to the Secondary Server Both The SixView Manager client connects to the Primary and Secondary Servers Secondary when Primary unavailable The SixView Manager client preferentially connects to the Primary using the Secondary as a backup NOTE Secondary when Primary unavailable or Both are the preferred methods in configurations supporting dual SixView Manager servers Enter Access Interval minutes Enter the number of minutes the SixView Manager Client process should wait before connecting to the SixView Manager server NOTE While lower values can result in more timely status reports with the SixView Manager Server it comes at an expense of increased data traffic which may be an issue when the connection utilizes a cellular modem with a serv
162. arded to a DMZ Host All incoming packets TCP UDP ICMP etc will be forwarded to the DMZ Host specified DMZ Host Address Enter the IP address of the DMZ Host This IP address will receive all packets destined for the interface specified Required NOTE Host Redirect and Service Access rules will apply first and may prevent certain ports from reaching the DMZ Host Source subnets via whitelist Select a whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking Firewall Subnet Whitelist Rules screen Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the DMZ Host Rules screen Status Networking Services Advanced Firewall DMZ Host Rules Interface DMZ Host Address Source Whitelist ethD 10 100 100 1 default Sixnet Wireless s Toll Free 800 489 7781 Mectranic Fax 314 426 0007 1645 LaGuardia Drive Web www jbmetlectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sienet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings saved e Click on the OK button to acknowledge the content e Click on the
163. are MD5 or SHA1 Phase 1 DH Group Select the DH Group you want to use for phase 1 IKE by choosing one of the values from the drop down list provided Options include e None Auto e Group 1 768 bits e Group 2 1024 bits e Group 5 1536 bits e Group 14 2048 bits This option selects the encryption level of the Diffie Hellman keys and these are Group 1 768 bits Group 2 1024 bits Group 5 1536 bits or Group 14 2048 bits Longer keys imply better security but at a cost of longer negotiation set up time during the initial connection establishment These settings must match on both ends of the connection Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual A value of None Auto means that no DH Group will be selected for this end of the tunnel and it will adopt the settings of its peer during connection initiation Phase 1 ISAKMP Time minutes Select how long in minutes the keying channel of a connection ISAKMP SA should last before being renegotiated Pre shared Key Specify the key to be exchanged for encryption negotiation during phase 1 IKE Key must not contain a double quote character Required Note The Pre Shared Key must match on both ends of the tunnel in order to work Local Peer ID Specify how the left participant should be identifi
164. ary Objects 1 Binary Input Combo Box that shows the different choices for Object 1 Binary Input that the user can select as a default variation 2 Binary Input Change Combo Box that shows the different choices for Object 2 Binary Input Change Events that the user can select as a default variation Sixnet Inc A Red Lion Business CON MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 10 Binary Output Status Combo Box that shows the different choices for Object 10 Binary Output that the user can select as a default variation Analog Objects 30 Analog Input Combo Box that shows the different choices for Object 30 Analog Input that the user can select as a default variation 31 Frozen Analog Input Combo Box that shows the different choices for Object 31 Frozen Analog Input that the user can select as a default variation only on Level 2 32 Analog Change Event Combo Box that shows the different choices for Object 32 Analog Input Change Events that the user can select as a default variation 33 Frozen Analog Event Combo Box that shows the different choices for Object 33 Frozen Analog Input Change Event that the user can select as a default variation only on Level 2 40 Analog Output Status Combo Box that shows the different choices for Object 40 Analog Output that the user can select as a default
165. ation Online Address Discrete input address is used as a station status indicator If provided it is set to True when any I O transfer to a remote station complete successfully and false otherwise Enter the Address of a local discrete input or blank if not used NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the Remote Station Table screen If more than one remote station is needed click and repeat the Add button e Click on the Save button to save the remote station configuration in the modbus xml file I O Transfer Status Admin Networking Advanced SN Industrial Pro model_number A Jtility Dynamic DNS Installed Firmware Ver ON Proxy Settings firmware revision F oixView Manager GPS Settings Device Senal Numbe SSH Server unit serial ystem Logging 3 TELNET Server Ethernet Interface Connection State IP mala ik Status usb 19 Ping Alive wn etho 19 SN MP Agent Local Remote Station Cellular Interface Activation Connection IPA IO Transfer ppp0 Reg Home Enabled 166 1 Cellular Uptime OD 1H 28M 6S i eega aE ee Disabled id Forwarding Serial Display Config File Toll Free 800 489 7 781 Sixnet Wireless Yr Fax 314 476 0007 4645 LaGuardia Drive ae ri Web www smnet com St Louis M
166. ation selected is TCP or UDP Click Save to store your configuration and move on to the next tab Data Link and Application Layer Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Data Link and Application Layer Status Admin Networking Services Advanced DNP3 Data Link and Application Layer Configuration Define Data Link Layer Properties Data Link Layer This Station DNP Address ll Same as IPm Station Number Enter Station DNP Address Min Response Dday ms Enable Self Address Enable Data Link Confirmation Data Link Retries Retry Timeout ms Define Application Layer Properties Application Layer Enable Application Layer Confirm Retries oO TimeOut ms oO Use diferent SEQ numbers for CONFIRM and RESPONSE PhysicalLink layer Object Mapping Default Variation _ Cancel Save Apply _ Toll Free 800 489 7 781 Sixnet Wireless Fax 314 4236 0007 4645 LaGuardia Drive AF d Web www sixnet com H E ie ia i TE afat m St Louis MO 63134 me f K i ied Send Email to Support 5200 Mal model_number Copyright 2012 Sixnet Inc Data Link Layer This Station DNP Address DNP address for the slave This value can be set by the user or automatically assigned by the Add On If the checkbox Same As station Number is selected then the DNP
167. ations placed on the system Extreme care should be exercised to prevent inadvertent use of this process e Firmware Update Used to upgrade the Sixnet firmware of the system e Gather Configs Used to obtain the configuration files to export e Gather Stats Used to obtain a snapshot of the running processes of the system e Manage System Configuration Used to Export or Import the GAU Master Configuration File e Package Installation Used to install system patches and updates e Reboot Used to reboot the system remotely NOTE This action will disconnect your login session while the system restarts You will need to login to the Sixnet router after 3 5 minutes to allow for reboot e System Time Used to change the Time Zone date and configure use of a NTP client Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 1 4 Networking The Networking Tab is where you can configure anything associated with networking the Sixnet router to the Internet and local interfaces The Networking Tab is organized into nine 9 sections e Cellular Connection o Configuration Used to configure the air card SIM on the unit o Provisioning Used to setup the service type on some not all air cards e DNS Settings Used to configure DNS request to an external server e Ethernet Interfaces
168. atus CSQ History Up 192 168 111 1 Down Up 192 168 0 1 Up Syslog Update History Cellular Interface Activation Connection IP Address Signal Strength pppo Searching Enabled 166 130 37 97 No Service 110 Cellular Uptime OD 3H 56M 1S oem Seems EGA Disabled v Toll Free 800 489 7781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support Man model_number Copyright 2012 Sixnet Inc e Click on the Arp Cache menu item and the following window will appear Status Admin Networking Services Advanced ARP Cache Address AWtype HWaddress Flags Mask 197 1668 0 ether T8 2B CB D1 SF 8D C A a im a E e Skipped Found 1 Toll Free 800 489 7 781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive h pa E i Web www sixnet com St Louis MO 63134 S IAT H f Send Email to Support gt 2nd Mal model_ number Copyright 2012 Sixnet Inc Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 2 2 Feature Codes The Feature Codes menu item will display the basic hardware configuration of the Sixnet router Status Networking Services Advanced Feature Codes JBM Feature code reader Version 20100322 Gateway R310058 serial 024495 Port 1 ttyS30 Console DTE Port 2 teysi Port 3
169. behavior is built in and not configurable Allow access by SixView Manager Select Yes to allow access for incoming TCP Port 7785 connections to trigger the SIXNET router for remote check in by the SixView Manager server Selecting No will allow the connection through to the device behind the selected interface Recommended setting is Yes Enter MAC Filter Enter a valid MAC address using the following format nn nn nn nn nn nn where nn is a number in hexadecimal form 0 9 a f A F to enable a MAC filter for use with IP Transparency A MAC filter allows only packets whose MAC address matches the filter value to be passed thru the Gateway device NOTE Leaving this field empty effectively disables MAC filtering Enable Out Of Band port re direct Select Yes to allow an Out of Band port to be redirected locally to this router When enabled the OOB Ports specified in the Advanced gt Out of Band Mgt section will be automatically allowed Recommended setting is Yes When also configuring Out of Band Met on this unit Enable port re directing Select Yes to allow redirecting of ports to a router beyond the Gateway device the one being configured Example A device beyond the Gateway device is running a WEB server on Port 80 but an upstream router is blocking Port 80 Redirecting traffic to another port say 8080 will allow communication with the server This would be setup as our External port 8080 redirec
170. ble for selecting your FTP site Status Networking Services Advanced Gather Stats include IPSEC Bar output Yes include gwinx fog fles Yes Select Delivery Method FTP a Destination Enter FTP Server Address Gather Sixnet Wireless Toll Free 800 489 7781 jor merty ibm Electronic Fax 314 426 0007 4645 LaGuardia Drive Web www jbimelectr onics com St Louis MO 63134 WWW SDNet corm Model Number Copyright 2010 Sixnet LLC o Enter the IP Address or URL to the FTP site of your choosing o Click on the Gather button NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 3 7 Manage System Configuration The Manage System Configuration menu item allows you to save a copy of the current system configuration i e Export This is useful when a confirmed good configuration is operational A backup can be exported for use should the configuration become corrupt or re configured in error Status Admin Networking Services Advanced Access settings Certificate Manager Firmware Version Factory Defaults SS Version Number Firmware Undate sather Configs 3 Serial Number Gather Stats A e a a Manage System ital Number Configuration Package Installation Interface Status Reboot Ethernet Interfac tem Time state IP Ad
171. cae suaneaasslievocedacaneansduidewiedoesesecesacdsscatece 50 Deel SV SHCME FO COGS acres oe vcises E AEE EENE EEEE V E ENEE SE O EASE 54 T OVE TN O ere E E EE E E E EE E O E 56 eA ONNI NON O is n E EE E EEE TEE E EEEE OOE A EE 58 3 2 10 Basa csc se ccs dress se vaca eee no seco o wa EAE E A A E E 60 32 C OT O eea E E E EE EE ENEE EEE EE EE OE A EE 62 Dee CTS OI irc ce eaten tates steve N sass case tds inate rs es auto sats ona asec ented cates canada tacc tects chav A AN 63 3 2 13 OT GR Onis Gal U61 EA EA ee ene ee eee eee ee ee ne een ee A eee eee 64 Des APM AD er ceeecceta cence eccetoaaucas tee nesseneeoseeq ices eedeuouesuatcnteapesea sons E eeeuiess 76 ee PCO CSS CIS oo cers ca T E E dense A E avenvareuseas sendioeeceuast on actonsddsdenvseeeatentdssuechom E Td Ioc CICA IG OT arent ncaie E RE ts nated aa duc saad nvloe tae wuss vse needed Sewanee Palma awed asada ane acute ate castors 79 oS Si xne t Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual Ss a fe Ma 21070 Vg BL ok 041 en OE ed Tee Ener hee E ee ee ee ee ee eee 80 S FTE A pe ee E E E E E EE T O eee 82 DD T O T E S E gts wna eee 84 TI G TS E E E E R EEA EE TE E NE E A EAE ETNEN 87 Ia DPM COM CULO MONGOO T ora re cee wana yale pass EE AEEA TOET TTOTTE 90 Io SA O sees R TEA E A E TEE TA TONA EEOAE EEE ETENE 97 A
172. ction Status Connection Status Connected IPv4 Connectivity Duration 02 40 26 IPv6 Connectivity Speed 1 0 Gbps Media State Duration 00 06 46 Speed 1 0 Gbps Activity 184 031 139 463 Received 2 525 828 NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual 1 2 5 Open Properties e Click on the Properties button Vista Windows 7 will display a popup window asking to confirm the operation e Click on the Continue button The display should look similar to the following XP Vista Windows 7 Local Area Connection Properties General Advanced Connect uzing E9 VMware Accelerated AMD PCNet Ad Intel R PRO 1000 MT Network Connection This connection uses the Following items el Client for Microsoft Networks ial File and Printer Sharing for Microsoft Networks This connection uses the following items o Client for Microsoft Networks G05 Packet Scheduler 5 GoS Packet Scheduler Z File and Printer Sharing for Microsoft Networks Internet Protocol TCP IP C Intemet Protocol Version 6 TCP IPv6 Sd Intemet Protocol Version 4 TCP IP v4 Install Uninstall 4 Link Layer Topology Discovery Mapper I O Driver F wh Link Layer Topology Discovery Responder Description Transmission Control Protocol
173. d Interface Alias Enter Sub interface number hz Enter IP Address j l e Scab cinerea co5 55 255 0 Enter Sub interface number Enter the desired Sub interface number in the file provided The valid range is 0 99 and each aliased interface must be uniquely numbered The final sub interface name will then be in the form ethx y where x is the root interface number and y is the sub interface number Enter IP Address This field specifies the IP Address of the sub interface Enter Netmask This field specifies the netmask to be assigned to the sub interface e Click on the OK button once the inputs are completed This will populate the Ethernet screen Once you are finished click Save and then Apply Sub Interface IP Address Subnet Mask 1 10 10 10 1 255 255 255 0 Sixnet Wireless F gt Toll Free 800 489 7781 tormariy ibm Electron Fax 314 426 0007 4645 LaGuardia Drive Web www jbmetectronics com St Louts MO 63134 WWW Sixnet com Model Number Copyright 2010 Sixnet LLC The usb Interfaces menu item allows the administrator to configure the usb port of Sixnet routers to meet their needs The default address is set for 192 168 111 1 with subnet mask of 255 255 255 0 NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networkin
174. d an untrusted interface Trusted Interface Identifies the trusted internal Interface Traffic from this interface will be permitted outbound Default is WAN ethO e Click on the Add button for Trusted Interface and the following pop up window will appear Add Trusted Interface Decay th Cancel OK Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Interface Choose an interface from the drop down lists provided You may add any number of interfaces up to as many exist on the device Each selection must be unique Trusted interfaces will not block traffic to from devices connected to that interface e Click on the OK button to populate the Trusted Interface screen Untrusted Interface Identifies the Primary Untrusted external Interface Default is pppO e Click on the Add button for Untrusted Interface and the following pop up window will appear Add Untrusted Interface Interface Interface Choose an interface from the drop down lists provided You may add any number of interfaces up to as many exist on the device Each selection must be unique Untrusted interfaces will block all incoming traffic from devices connected to this interface e Click on the OK button to populate the Untrusted Interface screen e Click
175. d internally to port 23 instead of to the device behind the specified Internal Interface NOTE For this option to function properly the Telnet Server must be enabled on port 23 via the Services tab Selecting Yes Will expand the display to include the port field for this parameter Allow TELNET access to this device Yes Enter TELNET Port 2023 Enter TELNET Port Enter the IP Port number to be used for Telnet access when Telnet access has been enabled The port chosen will be redirected locally Connections on this port number will not reach the device behind the specified Internal Interface Recommended setting is 2023 All Telnet traffic will be redirected locally to port 23 automatically This behavior is built in and not configurable Incoming connections on port 23 will reach the device behind the specified Internal Interface NOTE The Telnet Server settings need not be altered to support the specification of a port other than 23 here Allow SSH access to this device Select Yes to allow SSH access to this device Incoming connections on the specified port will be directed internally to port 22 instead of to the device behind the specified Internal Interface NOTE For this option to function properly the SSH Server must be enabled on port 22 via the Services tab Selecting Yes Will expand the display to include the port field for this parameter Allow SSH access to this device Yes gt Ente
176. d to be added for remote access Networking gt Firewall gt Service Access Rules Use CISCO APH Select Yes to enable the CISCO APH or No to prevent its use Recommended setting is Yes When connecting to a Cisco console port Local Binding Select Yes to enable Local Binding NOTE Local binding will prevent remote access to this port You will be required to Telnet SSH to the unit s command line and then telnet to the OOB port locally telnet localhost lt OOB_port gt TELNET Server Mode This option controls how some options negotiations will be performed with a TELNET client Recommended setting is Basic drop LF amp NUL is a commonly utilized setting The following options are available e Disabled No TELNET options negotiation is performed e Basic Common TELNET options negotiation is performed e Basic drop LF Linefeed characters x 0A are dropped e Basic drop LF amp NUL Cisco Preferred LF and NUL x 00 characters are dropped e Basic drop LF amp NUL HIGH LF NUL and any characters gt x 7F are dropped e Basic drop CR Carriage return characters x OD are dropped e Basic drop CR amp NUL CR and NUL x 00 characters are dropped e Basic drop CR amp NUL HIGH CR NUL x 00 and any characters gt x 7F are dropped NOTE Selecting the right value for your particular situation may require some experimentation The Basic Telnet Server will enable some
177. date the firmware gather the configurations to send to support for analysis gather a report on the functions of the router to send to support for analysis install system patches packages remotely reboot the router and configure the system time Tale D i e alallala e ifa a g ang ale Disabled bad T l K T 5 K ee ke j CO CERF z amp j Model Number Copyright 2010 Sixnet LLC NU Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL 877 8346 a red Worn business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 151 IndustrialPro Series Router User Manual 3 3 1 Access Settings The Access Settings menu item allows you to change how the unit s GUI interface is accessed either by HTTP or HTTPS You can also change the password used to access the GUI interface Click on the Access Settings menu item and the following window will appear Status Networking Services Advanced Access Settings Select Web Access Method Enter New Password Confirm New Password User gauser Controlled access Enter New Password Confirm New Password User techsup Limited access Enier New Password Confirm New Password Sixnet Wireless tormeriy jbr Electror s 4645 LaGuardia Drive a Web www Jbmelectronmcs com St Louis MO 63134 i www sbaet com Model Number Copyright 2010 Sixnet LLC To change the access method e Click on
178. ddress Link Status ethO Up 192 168 0 1 Up eth Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address signal Strength pppod gt ed Enabled SON AGN er EVDO REV A Sl ae aici Disabled Sixnet Wireless E Toll Free 800 489 7781 formerly jom Electronics e Fax 314 426 0007 4645 LaGuardia Drive Aafk Web www jbmelectronics com St Louis MO 63134 we eR Ee WWW sixnet com Model Number Copyright 2010 Sixnet LLC 3 6 1 IP Fallback IP Fallback is supported in Sixnet Routers in the IndustrialPro and EnterprisePro series To configure IP Fallback select the option from the Advanced menu The IP Fallback menu item allows you to configure the Sixnet router to failover between two interfaces ex Primary route on DSL Cable on ethO and secondary on Cellular if the primary loses Internet connection Sixnet Inc A Red Lion Business CONNEC ONITOR COI s red Mlle business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced IP Fallback IF Transparency Installed Firmware Version Cut of Band Mat Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address Link Status ethO Up a eth Up 192 158 1 Up Cellular Interface Activation Connection IP Address signal Strength pppo ed Enabled a ON Aa a E
179. ddress gt 10000 says VRRP settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says VRRP settings applied e Click on the OK button to acknowledge the content N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 6 5 Expert Mode The Expert Mode menu item allows you to edit the configuration files of a Sixnet IndustrialPro EnterprisePro router directly This option provides the ability to perform advanced configuration capabilities for complex configurations The Gateway Administration Utility GAU is XML based and writes the configuration to a XML based configuration file and then generates the necessary system configuration files Therefore it is not recommended that you perform configuration activities using this facility unless instructed to do so by Sixnet Technical Support WARNING Should you choose to edit the configuration files directly we encourage you to contact Sixnet Technical Support Once you have manually edited a configuration file without the use of the GAU you should refrain from any further configurations to that subsystem through the GAU as it will overwrite any changes you may have made
180. der to go to active state Some DTE Data Terminal Equipment devices required to go active if they provide DTR Data Terminal Ready signal Recommended Setting Yes if DTR is the connect signal Dial IP This option appears only if the Connect Mode is set to AT Command and then if the Dial IP option is set to Yes the IndustrialPro router expects to receive AT commands to initialize the serial port and also expects to receive ATDT lt IP Port gt in one of the following formats as a destination IP Port address for connectivity to the host processing server Recommended Setting No ATDT192 168 0 1 5000 ATDT192 168 0 1 5000 ATDT1921680000015000 ATDTdns com 5000 Disable Sending Ring This option appears only if the Connect Mode is set to AT Command This option eliminates the serial port from sending the RING and CONNECT message out the serial port once the server connection is available Recommended Setting No if you want the RING to go out serial port and Yes otherwise Ignore DTR This option needs to be set to Yes if the serial port is connected to a DTE device that only provides 3 wires Transmit Receive and Ground for communication or the DTE device could drop DTR signal while sending AT commands Recommended Setting Yes if a 3 wire connection is expected Connection Type Select the connection type you desire from the drop down list Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor
181. ders are LSW and MSW Long Word Order Controls the swapping of words within longs Ignored if using Daniel mode This is needed for configuring the serial slave application Supported orders are LSW and MSW Enable Daniel Mode Used Daniel mode extensions when dealing with longs and floats This is needed for configuring the serial slave application e Click on the OK button to populate the Serial Table screen e Click on the Save button to save the Serial configuration in the modbus xml file N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Display Config File Status Admin Networking Advanced device_family Administra Dynamic DNS Installed Firmware Ver SN Proxy Settings firmware revision _ g SixView Manager GPS Settings Device Senal Numbe SSH Server serial number System Logging System Uptime eae er 0D 0H 5M 59S ais Ping Alive Physical Interface Stal sy mp agent Ethernet Interface Connection State IP ik Gtatuc TE Up 19 Local Remote Station etho Up 19 IO Transfer Forwarding x 2 F Serial Cellular Interface Activation Connection IP Address Signal N A Reg Home Disabled N A HSPA Display Config File Cellular Uptime N A oT aa Sleeht E e 8ige at be Disabled X Toll Free 800 489 7781 Sixnet Wireless P i N Fax 31
182. dress Link Status ethd Up 192 168 0 1 Lp eth Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppod ed Enabled T Oron EVDO REV A Select auto update interval Disabled rd Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics aTh b z n Fax 314 426 0007 4645 LaGuardia Drive k V a aF Web www jbmelectronics com St Louis MO 63134 iFa TEETE WWW Ssixnet com Model Number Copyright 2010 Sixnet LLC a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the Manage System Configuration menu item and the following window will appear Status Admin Networking Services Advanced Default Import file handling Replace Select GAU Master Configuration File OO OO f Browse Upad Toll Free 800 489 7 781 Sinet Wireless P a Fax 314 426 0007 4645 LaGuardia Drive Web www snet com St Louis MO 63134 Send Email to Support model number Copyright 2012 Sixnet Inc To save a copy of the Sixnet router configuration e Click on the Export button e You will get a pop up window asking you to save to disk Opening config xml txt EJ You have chosen to open config xml txt which is a Text Document from http lt IP Address gt 10000 What should Firefox do with this File Open with Notepad defaut Peceseeeseceseee
183. drop down list provided if needed NU a red lion business Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 2 1 2 Set the User Name Password and APN If you are using a GPRS Edge or HSDPA based card enter the User Name Password and APN that was provided by your cellular carrier This information should have been packaged with your SIM chip If you do not have this information please contact your carrier s account representative or the carrier s support department before proceeding e Click the Apply button to save and activate the configuration NOTE The User Name Password and APN can be case sensitive Be certain that you use the exact information as provided by your carrier 2 1 3 Enter Provisioning Information if applicable For Sprint CDMA installations using the R3200 A2200 M1200 series or for Sprint Data link support additional information may be required Navigate to Networking gt Cellular gt Provisioning N Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Cellular Provisioning Currently Selected Carrier Sprint Currently Selected Modem Novatel E725 Detected E
184. ds to attempt a connection to this TCP destination before declaring it unreachable After the specified time the next destination will be attempted Valid range is 2 250 seconds Recommended Setting 10 seconds A value less than 10 seconds is not recommended for a wireless environment Address 2 Enter the client first alternative IP address that GWLNX uses to connect to the host server Required Port 2 Enter the client first alternative port address that GWLNX uses to connect to the host server port Required Connect Timeout 2 Specify the time in seconds to attempt a connection to this TCP destination before declaring it unreachable After the specified time the next destination will be attempted Valid range is 2 250 seconds Recommended Setting 10 seconds A value less than 10 seconds is not recommended for a wireless environment N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Address 3 Enter the client first alternative IP address that GWLNX uses to connect to the host server Required Port 3 Enter the client first alternative port address that GWLNX uses to connect to the host server port Required Connect Timeout 3 Specify the time in seconds to attempt a connection to this TCP destination before declaring it unreachable After the specified time
185. e eth0 eth Cellular Interface pppo Sixnet Wireless formerly jbm Electronics 4645 LaGuardia Drive St Louis MO 63134 Model Number NU Admin Networking Services Advanced Installed Firmware Version Firmware Version Number Device Serial Number Serial Number Physical Interface Status Connection State IP Address Link Status p 192 168 0 1 E D Lp 192 168 1 1 Lp IP Address 72 101 168 Connection Enabled CN signal Strength 120 EVDO REV A i Toll Free 800 489 7 731 Fax 314 476 0007 Web www jbmelectronics com WWW Sixnet com Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual If you refresh this screen every few minutes and notice that the IP Address is changing frequently it is possible that your router is connecting to the network and obtaining and IP address and then the connection to the cellular network is being dropped When the connection is re established the device is then issued a different IP address 2 3 2 Authentication Issues If you are using a GPRS EDGE HSDPA card and have at least three LEDs of signal on the front panel signal meter your radio connection to the network may be just fine The problem may lie in logging onto the cellular network Return to the screen shown be
186. e or No for manual control If the DHCP Relay service is required to be operational at all times then set to Yes If another process such as VRRP is going to dynamically enable disable DHCP Relay service as needed then set to No Adding the Interface Click on the Add button and the following pop up will appear Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Add Interfaces Select the interface you would like to receive its IP from the remote DHCP server from the drop down menu and click OK Adding the Remote DHCP Server Click on the Add button and the following pop up will appear Add Remote Server Remote Server OO O Ok Enter the IP Address or Fully Qualified Domain Name of all remote DHCP Servers available It is the responsibility of the remote DHCP Server to coordinate the issuing of DHCP addresses 3 5 2 Dynamic DNS The Dynamic DNS menu item allows you to configure a dynamic DNS name for the Sixnet router that does not have a static public IP Address and you are subscribed to a service providing Dynamic DNS such as DYNDNS ORG e Click on the Dynamic DNS menu item and the following window will appear Status Networking Services Advanced Dynamic DNS Enable Dynamic ONS No Sixnet Wireless P ai oll Free 800 489 7781 for mer bm Electror
187. e Web wwwJbmelectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC To add an IP in IP Tunnel e Click on the Add button and the following pop up window will appear Add IP in IP Tunnel Tunnel ID Enable Tunnel No z Tunnel ID Enter a unique numerical identifier in this field It will be used for naming the tunnel interface which will appear in the interface list as tunl1 tunl2 etc depending on the IDs provided Enable Tunnel Select Yes to enable the tunnel now This will expand the display to reveal the configuration fields NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Add IP in IP Tunnel Tunnel lO B Enable Tunnel Yes Local IP Address Local Subnet Remote IP Address Remote Subnet Time To Live Start Tunnel at boot Local IP Address Set the fixed local address for tunneled packets Note If supplied the Local IP Address must be an address on another interface of this host If not supplied tunneled packets can be received from any interface Local Subnet Set the local private IPIP network mask Remote IP Address Set the IP Address of the remote endpoint for this tunnel Remote Subnet Set the remote private IPIP network mask Time To Live Set a fixed Time To Live for tunne
188. e before being reported in the Event Report Queue Timeout field Minimum value 1 000 ms 1 second maximum value 3 600 000 ms 1 hour 3 The minimum number of events in the event queue required to trigger the generation of an unsolicited event report message in the Event Report Queue Threshold field 4 The maximum number of events to send in every unsolicited message Note When planning on using unsolicited responses there must be at least one DNP object configured to generate events on any of the three DNP event classes or else no events will be generated and thus no unsolicited responses will be generated by the station Event Detection Rate Select box to automatically set the detection rate Max time events in queue after disconnect TCP Server only Click to enable Enable Real Time Data Trace The DNP V3 00 Slave Driver can be configured to generate real time traces of every Master Slave DNP V3 00 transaction for diagnosis and debugging purposes The real time communication data traces can be enabled disabled at any time from the DNP configuration Add On and its ASCII output can be redirected either to a text file within the file system for later upload to a dumb terminal attached to an unassigned serial port of the station or even to a remote Telnet terminal session over the TCP IP network by entering the corresponding dev ttyp dev ttypO to dev ttyp3 telnet device Time Synchronization The station can be configured to request
189. e cases where the Sixnet router includes the use of a cellular modem the cellular network will provide this information to the Sixnet router and traffic will be default routed to the cellular network Therefore an additional default gateway should not be configured If a default gateway is specified and a cellular interface is activated the cellular interface will automatically become the default route Use Interface as Default Route If this option is set to yes the Sixnet router will forward any packets for which it does not have a route out through this interface This parameter should not be specified if the Sixnet router will be using a cellular card as the cellular interface will become the default gateway when it connects to the cellular carrier NOTE Should a cellular interface be activated subsequent to an Ethernet interface having already been specified as the default route the cellular interface will override the Ethernet default route If this is not done it will be impossible to route traffic over the cellular interface when it is activated Enter Maximum Transmission Unit MTU In computer networking the Maximum Transmission Unit MTU of a communications protocol of a layer is the size in bytes of the largest protocol data unit that the layer can pass onwards MTU parameters usually appear in association with a communications interface NIC serial port etc Standards Ethernet for example can fix the size of an MTU o
190. e component sub system service if it is currently running e Re Start Start the component sub system service or re start it if it is currently running 3 6 5 2 Predefined Interface Names The Predefined Interface Names menu item allows you to create a named interface for use in applications such as OpenVPN that require a logical interface i e tunO that the Sixnet router does not know about Using the Predefined Interface Name will place the name of the interface into the pull down menus of interface selections to be used by the system Status Admin Networking Installed Firmware Version Firmware Version Number Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State etho Up eth Up IP Address 72 101 201 31 Connection Enabled ail EEE Lisablect bi formerly jbm Electronics ag i 4645 LaGuardia Drive Lare TE a F t St Louis MO 63134 wi xine Model Number Cellular Interface Activation pppo Sixnet Wireless NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 Services IP Address 192 168 0 1 Advanced IF Fallback IP Transparency Out o Band Mat VRRP Link Status I P E P Signal Strength EVDO REV A 7 Toll Free 800 489 7781 Fax 314 4276 0007 Web www jbmelectronics com WWW Sixnet com Copyright 2010 Sixnet LLC T 1 518 8775173 F 1 518 877 8346 Indust
191. e network order to all transmitted TCP packets and will remove the 4 bytes from the received TCP packets Extended header normally is used as an indicator First Mid and Last when dealing with the large TCP messages and possibility of TCP IP packet fragmentation Recommended Setting None if TCP headers are not used Host IP Address Enter the host destination IP Address into this field This is Required if the device is acting as a TCP IP Client Recommended Setting Consult your network administrator Host IP Port Enter the host destination Port Address into this field This is Required if the device is acting as a TCP IP Client Recommended Setting Consult your network administrator Client Source Port Enter the Source Port Address into this field This is Required if the device is acting as a TCP IP client and using specific source port for TCP socket connection Recommended Setting Leave blank to use dynamic source port from TCP stack for socket connection Allow Peer To Re attach While Connected Select whether or not to allow TCP peer to re attach to our server while the socket is connected If enabled a new connection attempt from the same peer will be accepted and the previous TCP connection will be closed This can be useful to re establish a connection if the link is not closed gracefully Recommended Setting No do not allow if there is an active socket connection Listening IP Address Enter the listening IP Address
192. e service will bind for communications tests Recommended setting is None Source IP Address Enter the IP address to use as a source for communications tests Note This will be the source IP address of the PING packets but does not necessarily reflect the interface from which packets will traverse the unit Failure Command Script Choose the name of the command script to be executed when the PING test fails For example if Reboot is an option then when selected the wireless interface will be restarted Note Recommended setting is None for standard operation with no special behaviors The Reboot is useful when using the wireless cellular interface e Click Apply button for the changes to take effect and the following window will appear Sixnet Inc A Red Lion Business CONNE I Whi CC HOL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual A Ping Alive settings applied e Click on the OK button to acknowledge the content 3 5 10 SNMP Agent SNMP Simple Network Management Protocol is a standard way of querying networking devices to obtain statuses updates alerts and behaviors To retrieve SNMP data from the Sixnet device you must have a SNMP manager or Server at the head end The Sixnet Router will only act as an SNMP client providing data it is polled for It will not act as a manager to poll o
193. ed Ethernet Interface eth0 Enable This Interface Interface Speed Duplex Obtain Network Addresses via DHCP No Enter IF Address Required Enter Subnet Mask Required Enter Remote Gateway ee Use Remote Gateway as Default Route mA A fee 8 fe 8 pe Enter Maximum Transmission Unit MTU 1500 Reguired Interface Aliases Sub Interface IP Address Subnet Mask Edit Delete Interface VLANs Vian ID IP Address Subnet Mask Toll Free 800 489 7781 p a Fax 314 426 0007 Web www sixnet com Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 S j X n et Gateway R3300B G Copyright 2012 Sixnet Inc Send Email to Support 560d Ma Enable This Interface This field determines whether or not the specified Ethernet port is enabled or disabled allowing the administrator to disable the port if necessary Note 1 When the Save button is clicked the interface will not be immediately activated or deactivated but will be after the device is rebooted This allows for other configuration changes to be made to the device which can be committed at a later time When the Apply button is clicked the current settings will be saved and the interface will immediately be either deactivated or activated Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manu
194. ed for authentication Can be an IP address or a fully qualified domain name preceded by which is used as a literal string and not resolved Remote Peer ID Specify how the right participant should be identified for authentication Can be an IP address or a fully qualified domain name preceded by which is used as a literal string and not resolved Phase 2 Auth Type ESP Specifies the Phase 2 Whether authentication should be done as part of ESP encryption or separately using the AH none protocol Phase 2 Encryption Select the ESP encryption algorithm to be used for the connection Possible options are AES AES256 or 3DES Phase 2 Authentication Select the ESP authentication algorithm to be used for the connection Possible options are MDS or SHA1 Phase 2 ISAKMP Time minutes Select how long in minutes a particular instance of a connection a set of encryption authentication keys for user packets should last from successful negotiation to expiration Use Perfect Forward Secrecy Specifies whether or not the tunnel will use Perfect Forward Secrecy when negotiating cryptography parameters with the remote device NOTE This parameter must be set the same on the devices on both sides of the tunnel in order for a Security Association SA to be established This is one of the first things that should be checked when tunnel negotiation difficulties are encountered Dead Peer Detection Action This
195. edge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The expanded display will appear revealing the IP Transparency configuration field Status Admin Networking Services Advanced IP Transparency Assigned IP Address Assigned Netmask Assigned Gateway Enable iP Transparency ves Select Internal interface eti f Kd interface Speed Duplex 2 Enable DHCP Server ves DHCP Subnet Type DHCP Lease Time l4Hours rd Allow TELNET access to this device No 2 Allow SSH access to this device Enter SSH Port PAQUIN Allow access to Gateway Administration Utility Yes z Kd Allow access by Gateway Management Utility ves Enter MAC fitter a 2 Enable Out OfBand por re direct No Kd Enable port re directing No Enable trafic resinctons No Sixnet Wireless x Toll Free 800 489 7781 foc merty jbm Blectron Fax 314 476 0007 4645 LaGuardia Drive i s 3 WebowwwJibmetectronics com St Louis MO 63134 fs es www sixnet com Model Number Copyright 2010 Sixnet LLC Select Internal Interface Select the interface to be designated the internal interface by making the appropriate choice from the provided list The wireless IP will be issued out of this interface Interface Spoeed Duplex Select the Speed and Duple
196. eerereseseserne Do this automatically for fies ike this from now on a ewe e Click on the OK button and save the config xml txt file to your computer system NOTE Please note the directory where the file was saved in order to retrieve it when needed to put the file back onto the Sixnet router Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon busines 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual To Import a known good Sixnet router configuration Sixnet ared lon business Click on the Import button The file explorer of your computer system should appear File Upload x Lookin lt Directory File Located gt 3 O Pem Pore Revescscenceesececccescnsvsasccesd 5 B o ka x 2 gt x My Recent Documents contig xml txt w All Files v File name My Network Files of type Browse to the directory where the config xml txt file is located Click on the config xml txt file to highlight it Click on the Open button to populate the Browse window Status Networking Services Advanced System Configuration Manager ste iguration File Fit SOEUR EGUE Replace Select GAU Master Configuration File lt Directory File Located gt config xmi txt Browse Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmetectronics com WWW
197. either Auto High or Low and click on your selection to populate field Connection Behavior The Choose Connection Behavior allows you to change how the air card SIM stays connected to the tower There are two choices Persistent and On Demand Persistent In Persistent mode the unit will always attempt to maintain a cellular connection with the carrier s network This is the default setting On Demand In On Demand mode the connection to the cellular network will only be attempted when packets are destined to leave the wireless interface In addition after a period of Idle Time the connection will terminate To change the connection behavior to On Demand e Click on the drop down menu at the Choose Connection Behavior field e Click on the On Demand selection You will see an additional field appear on the screen Choose Connection Behavior Cellular MTU Dial on demand Idle Time 300 in Maximum Receive Idle Time Dial on demand Idle Time Allows you to enter the number of seconds the connection may be allowed to remain idle no data transmitted or received before closing the connection This will allow a DoD connection to automatically reset once idle so that any network usage is limited This is useful for an environment where constant usage of the POTS line is not desired Recommended time is 300 seconds 5 minutes This is defaulted to 600 seconds Cellular MTU Enter the MTU size you desire to use In
198. el Number Copyright 2010 Sixnet LLC Simply select OMA in the dropdown option and click apply This will already be the default operation of OMA capable devices When a connection is refused by the tower the unit will automatically attempt automatic provisioning at regular intervals You may click Force Provisioning to cause an immediate OMA attempt Your PRL will also be automatically updated to the latest version every 3 months To initiate an immediate PRL Update you may click the Force PRL Update button R 3300 SN 6600 or follow these instructions on R 3000 R 1000 A 2000 series units e Using a paper clip press the multi function button on the rear of the unit near the CONSOLE port e Hold for 5 seconds until the front RSSI lights all flash e Once the LEDs go out press the reset button 5 times until you see this pattern e Wait for the pattern to flash the binary 5 pattern in confirmation e The PRL Update will take place over the air providing you have an adequate connection established Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 2 2 Verify Cellular Connectivity Browse to the Status screen that appears Status Admin Networking Services Advanced device_family Administration Utility Installed Firmware Version firmware revision Device Senal Numb
199. en Allow Modbus To allow external devices to connect to the MODBUS Server via port 502 through untrusted interfaces on this unit select Yes otherwise select No Allow Web Interface Access To allow external devices to connect to the Gateway Administration Utility GAU through untrusted interfaces on this unit select Yes otherwise select No Allow SNMP Agent Access To allow external devices to connect to the SNMP Agent via port 161 through untrusted interfaces on this unit select Yes otherwise select No Note To restrict access for above services via a configured Whitelist click the checkbox marked Use Whitelist next to their corresponding service option and then select a Whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking Firewall gt Subnet Whitelist Rules screen Allow IPSEC Specify whether to allow ESP data as well as UDP port 500 to communicate with external devices through Untrusted interfaces Default is Yes Note This is necessary if you are planning to configure any IPSEC tunnels originating from the Sixnet router Allow NAT Traversal Specify whether to allow data on UDP port 4500 on un trusted interface Note This is necessary if you are planning to run any IPSEC tunnels through our device This would support a unit behind a trusted interface to make an IPSEC connection to a host beyon
200. end with ca csr crt key or pem Possible Choices include e IPsec Cert This will specify a certificate to be used to authenticate a VPN connection A server and client certificate will be required e IPsec Key An RSA key must be provided for any client certificate uploaded If this is signed with a password that will need to be entered in the IPSec as well e IPsec CA This specifies a Certificate Authority Please include a CA valid for each signed certificate e SSL This certificate will be available for SSL Connections as a Server Certificate or a Client Certificate e SSLVPN This certificate will be available for SSL VPN tunnels e Once you have entered a value into the Certificate Name field the Browse button will be enabled and can be clicked to select a file from your local system for upload When a valid file name is selected the Upload button is enabled and can be clicked to upload the selected file to the device The certificate file name can contain only upper and or lower case letters digits _ and must end with ca csr crt key or pem NOTE SSL type certificates must include the key and cert portions and the key must not be password encrypted Click on the file and click OK e Click on the OK button then click on the Apply button for changes to take effect 3 3 3 Factory Defaults The Factory Defaults menu item allows you to restore the configuration back to factory defau
201. ended to start with a locally accessible IP address to confirm communication to an interface s local subnet Then proceed to addresses on distant networks Your local default gateway is a good test and this IP can be found in your routing table A commonly available internet server available to test against is 4 2 2 2 Status i Networking Services Advanced Enter HostilP Address to test Bees Unspecified Ping Results for www google com PING www l google com 74 125 19 104 56184 bytes of data bytes from nuqd4s01 in f104 1e100 net 74 125 19 104 icmp seqrl trl 49 time 396 bytes from nuq04s01 in f104 1leloO net 74 125 19 104 icmp seqre ttl 49 time 399 bytes from nuqO4s01 in f1l04 1lel00 net 774 125 199 104 icmp seqqs trl 49 time 400 bytes from nuqO4s01 in f104 1e100 net 74 125 19 104 icmp seq 4 trl 49 time 400 bytes from nuq04s01 in f104 1leloO net 74 125 19 104 icmp seq s5 trl 49 time 400 bytes from nuq04s01 in f104 1leil0O net 74 125 19 104 icmp_seg56 ttl 49 time s56e0 bytes from nuqO4s01 in f104 1lel00 net 74 125 19 104 icmp seq trl 49 time 520 bytes from nuq04s01 in f104 1leloO net 74 125 19 104 icmp seq qs trl 49 time 400 bytes from nuq04s01 in f104 1leil0O net 74 125 19 104 lemp seqqa ttl 49 time 440 bytes from nuqO4s01 in f104 lel00 net 74 125 19 1049 icmp seq 1l0 ttl 49 time 42 WWW l google com ping statistics 10 packets transmitted 10 received OF packet loss time 9196ms rot minfavos
202. ening Port TCP Destination IP TCP Destination Port TCP Source Bind IP Label Enter a unique name to describe this connection SSL Listening IP Enter the IP to listen on for incoming SSL connections If not using static IP addresses it is recommended to use the Advanced Setup option Bind Interface for accepting TCP Connections instead Leave blank 0 0 0 0 to allow connections from any interface SSL Listening Port Enter the listening port for SSL connections Please note that this port must be allowed in the Firewall access rules for any external untrusted interface NOTE It may be helpful to review the results of Status Socket Statuses gt TCP Only to confirm that your choice of listening port is not already in use Ports under Local Address with a state of LISTEN are in use TCP Destination IP Enter the IP or Domain Name of the standard TCP server to which you would like to connect Use 127 0 0 1 for internal connection use only gwlinx Protocol Converter or OOB Encryption Setup TCP Destination Port Enter the Port number of the standard TCP server to which you would like to connect TCP Source Bind IP Enter the IP to bind to for outgoing TCP connections If not using static IP addresses it is recommended to use the Advanced option Bind Interface for outgoing TCP Connections Leave blank for normal operation no binding e Click on the OK button to populate the SSL Server screen NU Si X net Sixne
203. ent configuration applied e Click on the OK button to acknowledge the content NU Sixnet Inc A Red Lion Business a red ii eiai 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 151 IndustrialPro Series Router SSL Server User Manual The SSL Server menu item allows you to configure the Sixnet router to issue SSL certificates to requesting SSL clients Status Adm in Click on the SSL Server menu item and the following window will appear Networking Services Advanced SSL Server Enable SSL Sinet Wireless 4645 LaGuardia Drive St Louis MO 63134 model number N Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 Cancel Apply Toll Free 800 489 7 781 Fax 314 476 000 Web www sinet com Send Email to Support Copyright 2012 Sixnet Inc Click on the pull down menu at the Enable SSL Click on Yes and the display will expand to reveal the configuration fields IndustrialPro Series Router User Manual Status Admin Networking Services Advanced SSL Server SSL Server Stopped Enable SSL eee Summary Wait for Connection sec Idle Timeout min Pi ein e No Pem Fies Exist Advance Setup No Label SSL Listening IP SSL Listening Port TCP Destination IP TCP Destinatia Cancel Apply Toll Free
204. er serial number stem Uptime OD OH 54M 405 Physical Interface Status Ethernet Interface Connection State IP Address Link Status usb Up 192 168 111 1 Down etho Up 192 168 0 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppo Reg Home Enabled 166 130 37 97 HSPA Cellular Uptime OD OH 52M 515 EEE AEA Disabled Toll Free 800 489 7 781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive aa a a Web www sixnet com St Louis MO 63134 eli ee ie Send Email to Support 5200 gt model_number Copyright 201 Sixnet Inc As shown the router is receiving good signal from the cellular network it is connected and has been issued an IP address At this point if you previously verified that your air card worked properly in your PC laptop R3100 or verified that the SIM is activated R3300 SN6800 and have been accessing the GAU to configure your Sixnet gateway via its browser you should be able to access the Internet e Open a browser on the PC Laptop and attempt to browse the Internet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual NOTE Depending on the provisioning of your card particularly in corporate applications in which the Sixnet router is providing cellular backup connectivity to wired circuits your card may be restricted
205. ess 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Add Host Redirect Rule Orama Destination Port ot smige eeeme All Lntrusted New Destination IP Address New Destination Port Sdect Protocol Source subnets via Whitest Original Destination Port Enter the port that an external device will try to connect to This is the port that will be open on the specified interface Required Select Interface Click on the pull down menu to select the interface on which to open the specified port Incoming connections will be allowed New Destination IP Address Enter the IP Address that the incoming connection will be redirected to This can be an IP address within or beyond this device Required New Destination Port Enter the port that the incoming connection will be redirected to This may be the same port number or a different port number as the Original Destination Port Required Select Protocol Choose the protocol type for this port s data Options are TCP and UDP Source subnets via whitelist Select a whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking gt Firewall gt Subnet Whitelist Rules screen Add Host Redirect Rule Original Destination Port of sa ee gee DODO x New Destination IP Address New Destination Port Sdect Protocol Source subnets via Whiteli
206. et LLC e Click onthe Add button to add an instance for OOB Management and the following pop up window will appear Add Out Of Band Management Select Interface ysi Select Speed Select Bits Char BE Select Parity None z Select of Stop Bits Char BEE Enter Port tz ee No gt Local Binding No z TELNET Server Mode Select Interface Select the interface to be used via the provided drop down NOTE For Speed Bits Parity and Stop Bits consult the configuration of the remote device being attached this setting must be compatible Select Speed Select the desired interface speed to be used via the provided drop down Select Bits Char Select the word length bits per character to be used via the provided drop down Select Parity Select the parity to be used via the provided drop down Select of Stop Bits Char Select the number of stop bits to be used via the provided drop down NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Enter Port Enter a valid port number 1 65535 to be used for the connection Recommended setting is Take care to choose a port number not already used by other system services Consult Status gt Socket Statuses gt TCP Only for a list of ports currently in use Please note that a Firewall Allow rule will nee
207. etermines whether the firewall is enabled or disabled Default is Yes Note Disabling the Firewall will compromise not only security but many router functions of the unit Allow PING To allow ICMP echo responses from external devices through untrusted interfaces on this unit select Yes otherwise select No Allow SSH To allow external devices to connect to the SSH Server via port 22 through untrusted interfaces on this unit select Yes otherwise select No Note Setting this option to Yes does not enable the SSH server it just allows it to be accessible via the firewall when it is enabled The SSH Server may be enabled via the Services gt SSH Server screen Sixnet Inc A Red Lion Business NNEC ONITOR COI red Mlle iciocs 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual If the SSH Server is configured to use a port other than 22 a rule specifically for the alternate port will need to be added via the Networking gt Firewall gt Service Access Rules screen Allow Telnet To allow external devices to connect to the TELNET Server via port 23 through untrusted interfaces on this unit select Yes otherwise select No Note Setting this option to Yes does not enable the TELNET Server it just allows it to be accessible via the firewall when it is enabled The TELNET Server may be enabled via the Services gt TELNET Server scre
208. ety Appearance and N Sixnet ared lpn business Personalization Clock Language and Region Ease of Access Additional Options Classic View Recent Tasks View network status and tasks Connect to a network Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 Windows Firewall Turn Windows Firewall on or off Allow a program through Windows Firewall People Near Me Sign in or out of People Near Me Change People Near Me settings Sync Center Sync with other computers mobile devices or network folders View sync results Resolve sync conflicts CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual 1 2 3 Access Network Connection Settings e Click on the link to access network connection settings o XP Network Connections o Vista Windows 7 Network and Sharing Center The display should look similar to the following XP Network Connections Fie Edit View Favorites Tools Advanced Help Back Search Folders Ey Folder Sync E rosers OF Address Network Connections LAN or High Speed Internet Network Tasks Local 4rea Connection Create a new connection Connected Firewalled Set up a home or small Cad vMware Accelerated AMD PCN aa office network Change Windows Firewall settings See Also Q i Network Troubleshooter Other Places gt Contro
209. f valid addresses for a given network is determined by the value of the Netmask Some addresses are reserved for special uses such as network and broadcast For example if a netmask is 255 255 255 0 and the IP address assigned to the device is 192 168 1 3 then the range of valid addresses is 192 168 1 1 through 192 168 1 254 as 192 168 1 0 is the value reserved for the network and 192 168 1 255 is the value reserved for the broadcast address Subnet Mask This field specifies the subnet mask to be assigned to the Ethernet port when a Static IP address configuration is selected This field is only available when Obtain Network Addresses via DHCP has been set to No Required e N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Default Gateway This field specifies IP address of the default gateway to be assigned to the Ethernet port when a Static IP address configuration is selected This field will not be visible or accessible when a Dynamic IP address configuration is selected as the DHCP server will provide the Sixnet router with the default gateway that it should use If specified the Default Gateway will tell the Sixnet router the IP address of a router to which the Sixnet router should forward all traffic for which it does not already know a specific route In th
210. face Connection State IP Address Link Status System Information me 192 168 111 1 Down Sadia ae clic Up 192 168 6 20 Up Syslog Update History ping Connection IP Address Signal Strength pppo Enabled 166 130 12 34 UMTS 91 Socket Test Speed Test Disabled v5 Traceroute Sixnet Wireless P Toll Free 800 489 7781 4645 LaGuardia Drive Pax 314 426 0007 St Louis MO 63134 Webiwww aixnet com Copyright 2010 Sixnet LLC e Click on the Socket Test menu item and the following window will appear Status Admin Networking Services Advanced Sixnet Wireless i Toll Pree 800 489 7781 4645 LaGuardia Drive Pax 314 426 0007 St Louis MO 63134 Web iwww 4aixnet com Copyright 2010 Sixnet LLC NU a red lion business Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Type in the IP or URL and Port Address you wish to telnet to and click on the Test button to proceed with the TCP socket handshaking to verify and display socket availability The following screens illustrate the successful and failed test result Status Admin Networking Services Advanced AF Socket test wit teinet oaa es ea e tees 92 168 10 100 Enter Destination Port Address to test lM Telnet Results for 192 168 10 100 5001 Trying 192 168 10 100 35091 Connected to 192 168 10 100 Escape cha
211. feature can help detect when a remote end point is no longer communicating properly Once an error is detected the Hold state will only renegotiate the tunnel after new traffic destined for the tunnel is detected The Restart state will attempt to immediately reestablish the connection to the concentrator For this reason Restart may use more bandwidth and may not be the ideal choice for a limited data plan However if a host at the central site needs to initiate connections down to a local device through the tunnel Restart may be necessary so that the tunnel is always up and waiting for new data from the concentrator DPD Interval seconds Set the delay in seconds between Dead Peer Detection keepalives that are sent for this connection e Unlimited Data Plans 30 60 seconds e Limited Data Plans 1800 sec 30 minutes e xq Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual NOTE A low value will rapidly discover a broken tunnel however a great deal of bandwidth will be used This is not ideal for a limited data plan such as a cellular telemetry plan DPD Timeout seconds Set the length of time in seconds that the connection should remain active without hearing either a poll from our peer or a reply After this period has elapsed with no response and no traffic the peer
212. fers using MODBUS e Slave Station Status e Forwarding of MODBUS messages e Developing of third party applications using our SDK based on ELDK4 2 and the SIXNET IODB API Additionally the IndustrialPro will act as a MODBUS slave This allows MODBUS masters to request or update I O points in the IndustrialPro s I O database Modbus Configuration User interfaces will be provided to configure I O transfers the MODBUS forwarding table and serial interfaces MODBUS configuration data will be stored in an XML based file named modbus xml This file will contain the following sections e serials xml section to define the parameters used for serial ports e localStation xml section to define the local station number and name e remoteStations defines remote stations and the I O transfers associated with them e regAllocation defines the number of registers for each I O type e forwards defines the list of remote stations to forward MODBUS requests There are two methods to configure these sections e CLI The command line interface for the cellular modbus gateway IndustrialPro provides a Cisco style telnet command line interface It writes an XML configuration file which is used to drive the backend daemons e GUI Interface This method is a WEB based interface which is the focus of this documentation The user interfaces will have the ability to e Configure Display remote stations e Configure Display I O transfers NU Si X
213. figure the timeout for Keep Alives e Tunnel VPN Settings o GRE Tunnels Used to configure a Generic Routing Encapsulation Tunnel with a head end server o IP to IP Tunnels Used to configure IP to IP Tunnels o IPSEC Configuration Used to configure the Phase and Phase II of an IPSEC Tunnel Status Used to display the current status of an established IPSEC Tunnel Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 1 5 Services The Services Tab is where you can configure the various service offerings of the Sixnet router These services include DHCP Server Dynamic DNS SSH SSL and TELNET The Services Tab is organized into seven 11 sections e DHCP Server Used to configure one of the internal Ethernet interfaces to be a DHCP server and hand out IP Addresses to systems connected to the Sixnet router e Dynamic DNS Used to configure a dynamic DNS if a DDNS service such as dyndns org is utilized e SixView Manager Used to configure how the Sixnet router communicates with a Gateway Management Utility server e SSH Server Used to enable disable SSH access to the Sixnet router e SSL Connections o SSL Client Used to configure the Sixnet router to act as an SSL client o SSL Server Used to configure the Sixnet router to act as an SSL server e System Logging Used to configure re
214. from Internet access If this is the case you may want to instead test to insure that you are able to access your corporate network If you have any question as to your configuration please check with your network administrator If you were able to successfully access the Internet or your corporate network then congratulations your Sixnet router is up and running and you have successfully completed the Quick Start You may skip the troubleshooting section 2 2 1 Cellular Connectivity Troubleshooting NOTE If you were unable to access the Internet or your corporate network the section that follows will help you to determine the cause of your difficulties If you are reading this section you have followed all previous instructions and your Sixnet router is not communicating This section will provide additional information to isolate the cause of difficulties 2 2 2 Cellular Reception Before we get into specifics regarding how to identify and address specific problems that can be encountered it is important that we spend a moment talking about cellular signal reception and appropriate expectations All of the major cellular carriers expend significant sums insuring that we have excellent signal coverage within their coverage areas However they have no control over the environments in which we attempt to place or use our cellular devices The principles behind cellular data reception are similar to cellular phone reception Therefore
215. g Services Advanced _ Adm DNS Settings Install Firn PPP Dial Backup Dey PPF over Ethernet Static Routes TCP Global Setings Physi us Ethernet Interface Connec Address Link Status usb Up 192 168 111 1 Down eth0 Up 192 168 8 20 Up Cellular Interface Activation Connection IP Address Signal Strength pppo Unavailable Enabled 166 130 37 97 UMTS 91 ae ene miei Disabled v Sixnet Wireless a Toll Free 800 489 7781 4645 LaGuardia Drive P a Fax 314 426 0007 St Louis MO 63134 D Bi Web www sixnet com Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNECT MONITOR CC a red Lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual Click on the usb menu item and the following window will appear Status Admin Networking Services Advanced USB IP Interface Enable USB Interface eee selec 192 166 111 1 Aera a 255 255 256 0 Cancel Save Apply Sixnet Wireless i Toll Free 800 489 7781 4645 LaGuardia Drive Fax 314 426 0007 St Louis MO 63134 Web vvv sixnet com Copyright 2010 Sixnet LLC Select Yes to enable the USB interface e Enter the desired interface IP Address and Subnet Mask into their designated field Required The IP address identifies a device on a TCP IP network Every device on a network must have a unique address The range of valid addresses for a given network is determ
216. h a network architect for additional assistance Recommended setting is Any NU a red lion business Sixnet Inc A Red Lion Business CONNEC ONITOR COI 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual Ciphers This field is a list of openssl ciphers supported Please consult support staff before attempting to change Reference Google openssl cipher list for more information Recommended setting is RC4 MD5 RC4 SHA SSLv3 Certificate Specifying a certificate in client mode will use this certificate chain as a client side certificate chain Using client side certs is optional The certificates must be in PEM format with an unencrypted key not password protected when generated Use Admin7 gt Certificate Manager to install update certs Keep Alive Behavior This option enables TCP Keep alives on the underlying sockets The following options are supported None Keep alives not used All Keep alives enabled for all sockets Accept Keep alives enabled for listening server socket side connections only This applies to the clear text server for Client mode sockets or the SSL Encrypted server for Server mode sockets Remote Keep alives enabled for client initiated sockets Local Keep alives enabled for client connections bound to a local IP address You may need to adjust the master Keep alive timer via Networking gt TCP Global Settings NOTE
217. hat we have Added I O Range AI 0 7 to Test I O and now we see each register that can be edited and monitored for the Analog inputs You may enter values here and observe your IODB data from another device location to see those values get updated or you may initiate a change from another device input and observe the changes presented here on your Test I O interface NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Click on the I O CTRL menu item and the following window will appear Status i Networking Services Advanced Enable This Interface No Toll Free 800 489 7781 Sixnet Wireless Fax 314 426 0007 4645 LaGuardia Drive Pma Web www sixnet com St Louis MO 63134 IXTI e ft Send Email to Support gt gt gt BT 6821 HSPA Copyright 2012 Sixnet Inc From the drop down menu select Yes to enable this interface and the following window will appear Status Admin Networking Services Advanced I O CTRL Enable This Intaface Digital Input Digital Input Counter Digital Output Analog Input DIN O DIC 1075904512 DOUT 0 AIN 0 00 Digital Input Address Digita Input Counter Address Digital Output Address Analog Input Address Update Interva ms Required Enable Auto update S sm tee Every 3 seconds Toll Free
218. he content Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content Host Redirect Port Forwarding Rules The Host Redirect Rules menu item allows you to configure port forwarding rules that permit ports on external untrusted interfaces to be passed to ports on internal hosts on the same or different ports e Click on the Host Redirect Rules menu item and the following window will appear Networking Services Advanced Firewall Host Redirect Port Forwarding Rules Orig Dest Port Interface New Dest Addr New Dest Port Protocol Source White 443 All Untrusted 127 0 0 1 10000 TCP default 2022 All Untrusted 127 0 0 1 22 TCP default Sixnet Wireless Toll Free 800 489 7781 Fax 314 426 000 7 Web www jtiunelectronics com Wwww sbanet com foe mer if af igen 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sienet LLC To add a new host redirect rule e Click on the Add button and the following pop up window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon busin
219. hernet Interface Connection State IP Address Link Status eth0 Up 192 168 0 1 Up eth Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address signal Strength pppo z ed Enabled Te Once EVDO REV A atl eR ieee Disabled sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics amih k Fax 314 426 0007 4645 LaGuardia Drive a ar tn Web www jbmelectronics com St Louis MO 63134 a EP tr h www sixnet com Model Number Copyright 2010 Sixnet LLC a red ier business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the IP Transparency menu item and the following window will appear Status Networking Services Advanced IP Transparency Enable IP Transparency No Sixnet Wireless m Toli Free 800 489 7781 foemerty jbm Electrorii Fax 314 426 0007 4645 LaGuardia Drive Wer www Jbmelectronics com St Louis MO 63134 wWww sbmet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down at the Enable IP Transparency field e Click on Yes and a pop up window will appear The page at http lt IP Address gt 10000 says eS A sub system conflict has been detected The following service is enabled Firewall This will be effectively disabled while IP Transparency is enabled Do you wish to continue Cancel OD e Click on the OK button to acknowl
220. ho Yes Disabled Enable DHCP for eth1 Enable Default Gateway for ethi Disabled Enable DHCP for WiFi Enable Default Gateway for WIFI Enable DHCP for usb0 Enable Default Gateway for usbO0 No gt Enter Starting Address Required Enter Ending Address feguired ding address values define only t addr y Client MAC Address Client IP Address Apply Toll Free 800 489 7751 Fax 314 476 000 7 Web www sknet com Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Send Email to Support gt gt Mal model number Copyright 2012 Sixnet Inc Sixnet Inc A Red Lion Business CONNECT MONITOR CON T WJ PA i IVE Im CON I R IL a red Lior business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Global Settings Enter Domain name Enter the Domain Name that will be passed to DHCP Clients Use Sixnet Standard DNS Settings Choosing Yes will automatically use the DNS Servers obtained by this unit s internet connection and or entries specified in Networking DNS Settings This is the preferred method of operation Choosing No will allow you to issue custom DNS servers to connected DHCP Clients This will not affect any DNS Servers used by this unit for local domain resolution Enter Default Lease Time seconds Specify the amount of time in seconds that the DHCP Server will allow clients t
221. hov 8 1 0724 dev ethl proto kernel scope link ere 192 160 1 1 8 0 0724 dev ethO proto Kernel scope link src 192 168 0 1 Lp 92 16 2 16 27 0 0 078 dey lo scope link sre 127 0 0 1 Sixnet Wireless Toll Free 800 489 7781 to bm Electroni Fax 314 426 0007 4645 LaGuardia Drive gt 2 Web www jbmelectronics com St Louis MO 63134 whe www spcnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The Standard Routing Table will display the current routes for the Sixnet router and the static routes that have been configured for the router Status Admin Networking Services Advanced Home Aro Cache 3 Installed Firmware Version Feature Codes ee ee Firmware Version Number Firewall Rules Mevice Serial Number Policy Routing Table Serial Number standard Routing Table System Processes System Services Physical Interface Status system Information Connection State IP Address Link Status Up 192 168 0 1 Up Update History L p 199 168 11 U p vena menace Activation Connection IP Address signal Strength pppo ed Enabled es eel Pe EVDO REV A Select auto Update interval Disabled Fa Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics a W z Fax 314 426 0007 4645 LaGuardia Drive B a4afk ts
222. ial Number Details Serial Number Multicast oystem Processes Physical Interface Status oystem Services System Information Connection State IP Address 1927 166 0 LI P Update History E p IP Address f 2 7017 201 31 Connection Enabled a He eee Disabled CEIA WMLEnace Activation pppo Sixnet Wireless formerly jbm Electronics 4645 LaGuardia Drive St Louis MO 63134 Model Number NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 Advanced Link Status Signal Strength EYDO REM Fi Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com WWW sixnet com Copyright 2010 Sixnet LLC 877 8346 IndustrialPro Series Router User Manual e Click on the Multicast menu item and the following window will appear Status Networking Services Advanced Multicast Interface Information 01 00 5e 00 00 01 224 0 0 1 01 00 5e 00 00 01 224 0 0 1 224 0 0 1 Sixnet Wireless an Toll Free 800 489 7781 r be Fax 314 476 0007 tr Tt Oriy joe f ss 4645 LaGuardia Drive Web swwwJibmelectronics com St Louis MO 63134 WWW sicnet com Model Number Copyright 2010 Sixnet LLC Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manua
223. ialPro Series Router User Manual Status Admin Networking Services Advanced Transniff IP ATM Interface Enable Transniff IP ATM Daea TCP IP v Transniff Interface Port eth0 TCP IP Port Configuration Host IP Address Host IP Port Filter Configuration ATM IP Address Destination Port Number gt Toll Free 800 489 7781 Sixnet Wireless j Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support Gateway R3300B G Copyright 2012 Sixnet Inc Enable Transniff IP ATM Description Select Yes to enable the Transniff IP ATM Interface Recommended Setting Yes if you are using this Interface DVR Connectivity Description This option allows you to select this device connectivity to your DVR Select TCP IP if connecting to DVR via Ethernet port and select Serial if connecting to DVR via TTYS1 port e These settings will need to match the DVR being connected for them to communicate properly If TCP IP is selected you are required to enter the HOST IP address and HOST port If Serial is selected speed length parity and stop bit of the HOST are required Transniff Interface Port Description This option allow you to select which Ethernet port to sniff for the ATM Request Reply transaction packets Select ethO if using WAN port and select eth1 if using LAN port Recommended Setting ethO Standard port ZN Sixnet Sixnet Inc A Red Lion Business CONNEC
224. ice plan where cost is based on bandwidth usage A value of 220 is suggested for Cellular carriers that use an inactivity timeout of four hours Enter Error Interval minutes Enter the number of minutes the SixView Manager Client should wait before re attempting a previously failed check in attempt Select Access Method Select the desired Access Method from the provided drop down Unencrypted http Faster but less secure Encrypted https Slower but more secure NOTE The encrypted method adds significant overhead which may be a consideration when using a cellular modem connection For example if an ipsec_restart is an option then when selected will be run whenever the fallback logic selects and activates this interface Enter SixView Manager Server Port If the SixView Manager Server has been configured to accept connections on a port other than its standard default that custom port number should be entered in this field The administrator of the SixView Manager Server will be able to provide you with the necessary information to properly set this parameter Default 18080 for http 18081 for https Select Interface Select the name of the interface to which the SixView Manager Client will bind for communications with the SixView Manager Server e Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialP
225. ices Displays list of services and current status on or off e System Information Displays information on Filesystem utilization and Memory Usage e Syslog Displays current syslog information with options to change and search the syslog information e Update History Displays list of updates to the system e Diagnostic Tools Connectivity testing tools o Ping Allows you to ping an external domain or IP Address o Socket Test Allows you to telnet to desire destination IP and Port address and display the result of socket connection oO Speed Test Allows you to test the bandwidth and latency of an activated unit s cellular connection o Ping Allows you to ping an external domain or IP Address gt lt Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 1 3 Admin The Admin Tab is where you can configure how the Sixnet router is accessed update the firmware reset the system to default set the system time and reboot the Sixnet router remotely The Admin Tab is organized into ten 10 sections e Access Settings Changes access from HTTP to HTTPS and changes the password used to login e Certificate Manager Manage the SSL certificates used by the system e Factory Defaults Restore system to factory defaults WARNING This action will delete all custom configur
226. ide prior to transmitting some data to the remote serial device This can be useful to discard initial line noise remnants from modem connections before an ENQ is issued or other start data message types from a TCP host Visa Mode Unused This is automatically enabled in the Visa engine as it awaits a STX Recommended Setting No Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Disable Ack Acknowledgement behavior in supported Message Mode Transparent Mode Unused Visa Mode Once a message is received from the serial device ATM POS and the LRC is valid this will disable sending an ACK Certain ATM POS devices will fail if sent an ACK and rather used the response message from the TCP host as an implied ACK Certain ATM POS devices require an ACK before receiving the response message from the TCP host Recommended Setting No Pass Through Ack Passing Acknowledgement in supported Message Mode Transparent Mode Unused Visa Mode When an ACK is received from an ATM POS device pass that up to the host processor Recommended Setting No unless using a SmartConnect device at the host processing side Enter Address 1 For coordination with SSL Connections use 127 0 0 1 When using ANSWER mode this is a Client Primary IP address that GWLNX application uses to connect to the
227. iiniencdinsse eddies Error Bookmark not defined De VS CO 1 EA E E A E E E A E A E A E 208 Dee TEENETE IN e E aE E IEE EEE E EEEE OEE EEE E ENEE E E S 209 EE a Fa E ESA EE A E E O E E AE E E AE E AE E E E NE 210 Fod DONMA O ei otc oct va oes E EE E E E E E E E 212 DoD DIOGO EE E ENEE E EEEE EA ENEE E EE EEA Error Bookmark not defined FIA LO SUIS erore EEA N E E E E EE OE E EEE AES 231 P DN ee nee Re ON ee ee ee ee eee er ee eee eee ee 236 3 6 NO I A aos asc epee E aoe sconsseauea sp ocesceuesquseoo cctscass sucvesenosesaeupices aceceevanassosceaepaceueecvocesens aeeuceaseeeneaur anaes 246 A T 6 aes eg eR ere ee OPO eT ORE ee eee REESE ere ere nee te cere noe R een ere ee eee ee eee ee 246 L02 IPIT ro a eM E oe RPE E COO RT Re ORT an oer pe eh ee ee ne ener eee err Error Bookmark not defined 3 6 3 Out Of Band VCCI sects ates ate cunnctenicesatasacuneeeanienciesemactianseseiadanvacteaterialesesenctcantenatasse Error Bookmark not defined 3 6 4 Virtual Routing Redundancy Protocol VRRP cccccccccccccecsssseeeeessseseeceecccceeeeeeeaaaaaseesseeeeeeeeees Error Bookmark not defined A 2 5 012s ts 012 en Pee eS E re ee eT ne em eee ee eee Error Bookmark not defined 08 0 EEL Ca 8 eee cee Re eT eee ee er eee me re eee em ee ere re ee er ee tT Error Bookmark not defined POC FFI esate cess ssa aus ected cee ee csc E E ee waa cp tse arasg pn eeu ae ee 271 200 2 Cponnecl Table OI oUr OT saririsa E N N A R Error Bookmark not defined O A O EE E
228. ile attempting a tower connection e Once the signal lights remain steady a connection to the cellular network has been achieved at the signal strength indicated e SN Series When the WAN light is on steady a ppp connection to the tower has been achieved e For more information consult the Provisioning Section detailed under the Networking gt Cellular gt Provisioning screen section in Part III NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual For Sprint OMA automatic activation provisioning capable devices the screen should appear Status Networking Services Advanced Cellular Provisioning Currently Selected Carrier Sprint Currently Selected Modem Novatel E725 Detected ESN Sh5b014 Modem Manufacturer Novatel Vireless Inc Modem Model E725 SPRINT Modem supports OMA no Modem Firmware Version m 800A RAPTOR_SPRINT 145 Apr 03 2007 17 12 43 PRL Version 20227 Detected NA Mobile Directory Nurnber MDN 201843132 Force Provisioning Now M view Card Stats Log Sole il seems Mobile IP prefered Sync system time to cellutar network time Yes Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electronios Fax 314 426 0007 1645 LaGuardia Drive Sh Aar Web www jbmelectronics com St Louis MO 63134 teal i www sbonet com Mod
229. ime Zone field To configure the date and time for your Sixnet router there are three options Option 1 Manual Configuration Current System Date MMIDDIVYYY o f he f 2010 Current System Time HH MM S3S eo f Ss 24 e Click on the individual fields and make changes to suit e Click on the Apply button NOTE The Hour field is on the 24 hour time clock range 00 24 This page verifies the Month Day Year Hour Minute and Seconds conform to expected inputs For example month range from 01 12 days range from 01 31 checks for limit according to month i e Jan has 31 days Feb has 28 or 29 depending on year etc Option 2 Use Local System Time Configuration Use Local System Time 4 16 2010 20 42 03 e Click on the Use Local System Time button e Click on the Apply button Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Option 3 Sync to NTP Server e Click on the pull down menu next to the Sync to NTP Server Syne to NTP Server No No e Click on Yes and the following window will appear Status Networking Services Advanced System Time Time Zone Cm Yes Enter NTP Server NamefiP Update frequency Hourly Cancel Apply loll Free 800 489 7781 Fax 314 426 000 7 Webl
230. ined by the value of the Netmask Some addresses are reserved for special uses such as network and broadcast For example if a netmask is 255 255 255 0 and the IP address assigned to the device is 192 168 1 3 then the range of valid addresses is 192 168 1 1 through 192 168 1 254 as 192 168 1 0 is the value reserved for the network and 192 168 1 255 is the value reserved for the broadcast address e Click on Save button for changes to be saved without activation the interface e Click on Apply button for changes to be saved and activate this interface Switch Control NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced __ Switch Control Settings Split Lan Enable Cancel Toll Free 800 489 7 781 Sixnet Wireless Fax 314 4296 0007 4645 LaGuardia Drive Web www sonet com St Lous MO 63134 Send Email to Support model_number Copyright 2012 Sixnet Inc This mode is only available on RAM 6x21 5 port equipped hardware The purpose of the Switch Control function is to create a WAN LAN separation similar to what is seen on the R series router This gives the user the ability to create a divided network with additional capabilities Switch Control Settings Split LAN Enable This will alter the switch port
231. ing No Enable traffic restrictions ves Traffic Restricti Select method of traffic restnction None Delete Sixnet Wireless P Toll Free 800 489 7781 A i ALA a Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 www sixnet com Model Number Copyrigit 2010 Sienet LLC Select method of traffic restriction This field is enabled when Traffic Restrictions have been enabled Select the restriction mode from the list provided None No filtering is performed Only Allow connections to from the associated subnet list only Inbound and Outbound Restrictions In Allow new incoming connections from the associated subnet list only but allow any originating outbound connections from the host behind the SIXNET router Inbound Restriction e Click on the Add button to add a subnet restriction and the following pop up window will appear ne DD _ YE Ss S Add Subnet Restrictions X NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Enter Subnet Enter subnet range for which to restrict traffic in the CIDR form nnn nnn nnn nnn xx where nnn is the IP Address and xx is the subnet in Network Bits format e Click on the OK button to populate the Traffic Restrictions screen Enable portre directing No
232. into this field This is Required if the device is acting as a TCP IP Server If set to 0 0 0 0 any remote client can connect to our listening port and if set to a specific IP only client with configured specific IP can connect to our listening port Recommended Setting lt 0 0 0 0 gt to allow any client to connect to the listening port Listening IP Port Enter the listening Port number into this field This is Required if the device is acting as a TCP IP Server Recommended Setting Consult your network administrator for client application destination port number Note Take care to choose a port number not already used by other system services Consult Status gt Socket Statuses TCP Only for a list of ports currently in use Please note that a Firewall Allow rule will need to be added for remote access Networking Firewall Service Access Rules Click on the Apply button and the following pop up window will appear Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Apply Operation Succeeded Click on the OK button to acknowledge the content has been updated 3 6 6 2 Connect Table Configuration The Connect Table menu item allows you to configure the communication ports behavior via Serial or Modem using Dialed Number Identification Service DNIS method
233. ire and Wait for Reply are the only modes used to send an I O transfer Port The port that the I O request is being sent across The supported ports are ttyS1 UDP and TCP If UDP or TCP port is used the remote station selected for this I O transfer should have its IP address defined Command Type The commands used for I O transfers are e READ Used for reading MODBUS registers from the remote station e WRITE Write MODBUS output registers to the remote station e WRITE_SINGLE Write a single MODBUS discrete or analog output register to the remote station Note Only an option when writing a single discrete output or single analog output Local Type I O type on the local station See Table2 I O Types and Limits Local Address First address of the local I O used for the I O transfer Valid values are O through number of registers configured for specified I O type Remote Type O type on the remote station See Table 2 3 4 5 I O Types and Limits NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Remote Address First register address for the remote I O used for the I O transfer Valid values are 1 65536 Number of Registers Number of registers requested in the I O transfer This must be 1 if the WRITE_SINGLE command is selected See Table 2 3 4 5 I O
234. is available from U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 Canadian Compliance Statement This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du Reglement sur le mat rial brouilleur du Canada Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 6 Warranty Sixnet provides a limited hardware warranty for the router which consists of the following e This warranty is effective for one year from the delivery date of the router to the purchaser e The purchaser is responsible for returning the defective unit to our factory freight prepaid e f the router is under warranty we will repair it at our cost and return it freight prepaid via UPS ground service e lf the router is not covered by the warranty we will notify you of the repair charges We will not repair the router without your permission e Repairs are guaranteed for 90 days or the remainder of the warranty whichever is longer Buyer s remedies for breach of warranty shall be limited to repair or replacement subject to adjustment as stated herein or full or partial adjustment to purchase price Sixnet routers are provided with the following warranty 1
235. its configuration information from its peer either via PPP or DHCP Alternate DNS Servers 1 In the event that a DNS query is submitted to the Primary DNS Server and a response is not received possibly because the host is down the Sixnet router will forward the query to the Alternate DNS servers 1 if they are specified Note This setting may be overridden if a network interface is set to obtain its configuration information from its peer either via PPP or DHCP Alternate DNS Servers 2 In the event that a DNS query is submitted to the Primary DNS Server and Alternate DNS Server 1 and a response is not received possibly because the host is down the Sixnet router will forward the query to the Alternate DNS servers 2 if they are specified Note This setting may be overridden if a network interface is set to obtain its configuration information from its peer either via PPP or DHCP NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Static Host Entries Static Host Entries may be added for local hosts allowing the Sixnet router to resolve local host names to IP addresses if requested 3 4 3 Network Interfaces The Ethernet Interfaces menu item allows the administrator to configure the Ethernet ports of Sixnet routers to meet their needs The R3100 R3300 has two E
236. ive Fha Ie ra Web www siknet com St Louis MO 63134 p j f Send Email to Support 5200 Mal model number Copyright 2012 Sixnet Inc Enter Configuration Description Enter a description to describe this connection Sixnet Inc A Red Lion Business CON gt T MONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Serial Port Configuration Line Speed Select the desired interface speed to be used via the provided drop down Independent Activation This option determines if the Serial Port of the device will accept data before the remote side is active At least one of the two sides in the configuration must be set for Independent Activation If neither side is set then the device will not accept data This function provides integrity for the device by preventing data from being accepted until it can be delivered successfully Recommended Setting Yes For standard usage No For serial to TCP Server configuration to insure there is a TCP Server socket available before marking the serial port active Word Length Select the word length bits per character to be used via the provided drop down Parity Select the parity to be used via the provided drop down Stop Bit Select the number of stop bits to be used via the provided drop down Connect Mode If this option is set to No the device will expect to receive AT Commands in or
237. k Our default community string for the JBMELECTRONICS MIB is public Allow Serial Number OID Select Yes to allow users and management systems to retrieve the unit serial number from the SNMP Agent If No is selected a query of the serial number OID will return UNKNOWN e Click Apply button for the changes to take effect and the following window will appear SNMP Agent settings saved and applied e Click on the OK button to acknowledge the content You should now see your MIB Manager be able to poll and display data collected from the Sixnet device If you are behind a firewall you will need to configure it to allow external SNMP connections to the IP address of the device on port 161 Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 5 11 Modbus This option is only supported if the IndustrialPro router has been upgraded to IndustrialPro RAM The IndustrialPro RAM firmware MODBUS application allows it to act as a MODBUS Master acting as an I O concentrator for MODBUS devices I O for these devices can be read or written using MODBUS I O transfers with the IndustrialPro acting as a MODBUS master I O data is stored in a local I O database This feature is not available on the R Series Enterprise Routers The IndustrialPro RAM will support e O trans
238. l 3 2 5 Routing Information The Routing Information is sub sectioned into Policy Routing Table and Standard Routing Table sections Status Admin Networking Services Advanced Home Ar p Cache j installed Firmware Version Feature Codes Firmware VYersion Number Firewall Rules Device Serial Number Policy Routing Table Serial Number standard Routing Table system Processes System Services Physical Interface Status sical Interface Status system Information Connection State IP Address Link Status Lp 192 168 1 1 Up LIp 192 168 0 1 Up Update History Cenuiaiiuenace Activation Connection IP Address Signal Strength pppo ed Enabled ae NO 20 e EVDO REV A Saale Lisabled bal Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics aTh ia Fax 314 426 0007 4645 LaGuardia Drive a ar bEes Web www jbmelectronics com St Louis MO 63134 y fad Fur amp WWW sixnet com Model Number Copyright 2010 Sixnet LLC a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The Policy Routing Table menu item displays information on the policy rules the route tables for each individual interface and the general routes for the Sixnet router Status Admin Networking Services Advanced Home Aro Cache J installed Firmware Version Feature Codes S a Firmware Version Number Fi
239. l Panel E My Network Places My Documents My Computer Details Network Connections System Folder Vista Windows 7 f 5 fos GU Network and Internet Network and Sharing Center Search p Laas Network and Sharing Center View computers and devices View full map Connect to a network Set up a connection or network A A E lt Manage network connections i E WIN L65FAMN41DM MSHOME Internet Diagnose and repair This computer Di MSHOME Private network Customize Access Local and Internet Connection Local Area Connection View status l Sharing and Discovery Network discovery File sharing Off Public folder sharing Off Printer sharing Off Password protected sharing On See also Media sharing Off Internet Options Show me all the files and folders I am sharing Windows Firewall Show me all the shared network folders on this computer _ Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Hon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 RAMG6000 and IndustrialPro Series Router User Manual 1 2 4 Access Local Area Connection e Click on the link to access the local area connection o XP Local Area Connection icon o Vista Windows 7 View Status next to Local Area Connection The display should look similar to the following XP Vista Windows 7 Local Area Conne
240. l to connect to its remote peer now and after any reboot e Click on the pull down menu at the Enable Tunnel field e Click on Yes to reveal the IPSEC Tunnel configuration fields NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 A X a red lion business IndustrialPro Series Router User Manual Add IPSEC Tunnel Tunnag Name a Required Enable Tunnd Tunnd Type Tunnd Negotiation Mode Phase 1 Encryption AES l Phase 1 Authentication BiH ECH Group 2 1024 bits Phase 1 ISAKMP Time minutes a Pre Shared Key Required Loca Peer ID Remote Peer ID Phase 2 Auth Type Phase 2 Encryption Phase 2 Authentication Oo Co HHE i a EI KI aa a Phase 2 ISAKMP Time minutes Use Perfect Forward Secrecy Bis Di eS eee ene Restart DFO Interval seconds AJ LD pas z I DPD Timeout seconds on i oo z ad Lf TI T l Local Public IP Address Local Source IP Loca Gateway IP Address Loca Prvate Subnet s Remote Public IP Address Remote Gateway IP Address Remote Private Subnet s Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 PX_FRRIAL RAAT f O ww Ww l k T 1 518 877 5173 F 1 D MONITOR CONTRO EE DEN t IFS i the a i ww i ia 7 8346 IndustrialPro Se
241. lPro Series Router User Manual If the pppO interface does not show an IP address this could indicate that the cellular air card R3100 R1100 or internal SIM Module has not been properly activated Low or invalid signal strength may also contribute to the issue Please contact your service provider to ensure proper activation You may need to enter provisioning information in the Networking Cellular Provisioning screen Consult Section 2 1 in this document for more information 1 3 2 SSH TELNET Serial RS232 Connections to Sixnet Routers For alternative connections to the Sixnet router please contact Sixnet Technical Support Group for additional related documentation 2 Cellular Connections 2 1 Cellular Card Configuration Cellular connectivity can be obtained through the use of an internal embedded RF Module or on the R series with the USB option you may insert a USB Aircard dongle Your Sixnet router is able to detect many USB cellular cards but some must still be configured manually If you are using a GPRS EDGE or HSDPA card that requires the use of a userid password and APN configure your card manually as covered in the next section If you are using one of the newer 1xRTT 1xEVDO 1xEVDO rev A USB based cards your Sixnet router has probably automatically detected configured and activated your cellular connection for you so you can skip this section and proceed to the next section to verify your cellular connectivity
242. led packets Recommended setting is 64 Start Tunnel at boot Select Yes to allow the interface to become active at system start e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says eS Save operation succeeded e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Operation Succeeded Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to acknowledge the content IPSEC The IPSEC menu item is organized into two sub sections Configuration and Status IPSEC Configuration The Configuration menu item allows you to configure an IPSEC Tunnel to establish secured communications between two or more networks across the Internet Admin Networking Services Advanced DNS Settings Instal F irr PPP Dial Backup EC PPP over Ethernet static Routes TCP Global Setings Phy GRE Tunnels Ethernet Interface ethd eth Cellular Interface pppo ate eile Disabled Sixnet Wireless formerly jbm Electronics 4645 LaGuardia Drive St Louis MO 63134 Model Number Activation Connection State E j
243. less directed by WSBU Development Group Support staff e Click on the Install button and the following pop up window will appear Operation Succeeded K e Click on the OK button to acknowledge the content 3 6 6 4 Install Configuration The Install Configuration menu item allows you to install the new Gwlnx configuration on Sixnet IndustrialPro or R Series router devices gt lt Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the Advanced gt Gwlnx7 Install Configuration menu item and the following window will appear Admin Networking Services Advanced ___Gwinx Configuration File Installation s ass sess Select Gwinx Configuration File ee L Bons Toll Free 800 489 7781 ee E Fax 314 476 0007 Sixnet Wireless Web www sixnet com 4645 LaGuardia Drive a an eae St Louis P 63134 Me z a S S Send Email to Support Model Number Copyright 2012 Sixnet LLC Select Gwlnx Configuration File Click the Browse button to select a gwlnx configuration file that is provided by WSBU Development Group Support staff to upload from your local system Required Recommended Setting Do not upload new configuration files unless directed by WSBU Development Group Support staff e Click on the Install butt
244. ll appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content Subnet Blacklist Rules NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The Subnet Blacklist Rules menu item allows you to define a single IP Address or an entire network that you do not want to allow access into the network behind the Sixnet router e Click on the Subnet Blacklist Rules menu item and the following window will appear Status Networking Services Advanced Firewall Subnet Blacklist Rules Subnet Sixnet Wireless a Toll Free 800 489 7781 Fax 314 426 0007 Web www Jbmelectronics com Www sbonet com Por merly jor rieceror 4645 LaGuardia Drive St Louis MO 63134 Model Number Copyright 2010 Sixnet LLC To add a new item to the list e Click on the Add button and the following pop up window will appear Add Subnet Blacklist Rule Enter Subnet To Blacklist o sis Enter Subnet To Blacklist Enter the network to be banned from making any incoming connections using IP CIDR notation To allow data from any source enter 0 0 0 0 0 To specify a single host use x x x x 32 where x x x x is the host s IP address This will override any other section s rules All
245. logy 2G vs 3G vs 4G and signal strength Below is the similar speed test result Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Enter notes to be included with the test results in the box provided below Results JBN Throughput Test Report Serial 6821 3048040034 Up Ping BSST kb s ms dE 232 64 812 21 234 80 2181 02 213 04 608 51 224 56 603 78 266 24 611 92 Averages Download Speed 1981 88 kb s Upload Speed 241 28 kb s Latency 963 49 ms Sixnet Wireless 4645 LaGuardia Drive t Louis MO 63134 ie Sixnet Sixnet Inc A Red Lion Business a red Irn busines 331 Ushers Road Ballston Lake NY 12019 Toll Free 800 489 77381 Fax 314 426 0007 Web www sixnet com Copyright 2010 Sixnet LLC CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The Traceroute menu item will allows you to watch the route traverse the Internet to the specified IP Address or URL Status Admin Networking Services Advanced Home Arp Cache Installed Firmware Version Feature Codes Ei i Rul Firmware Version Number rewal Rules Device Serial Number Serial Number System Processes Physical Interface Status Connection State IP Address Link Status
246. low Status i Networking Services Advanced Cellular Connection Currently installed Modem No modem detected Enable interface 2 Select Cellular Carrier ATAT Sas lay ieee trialXXx intemettial Confirm Password Select APN Context gt SUC e bolus Option GT HSDPA Enable Modem Auto Detection ViewlChange Advanced Options Sixnet Wireless loll Free 800 489 7781 rly ibm Elect x Fax 314 426 0007 46 451 aGuardia Drive A Di Web www jbmelectronics com St Louis MO 63134 i Wr S www sixnet com Model Number Copyright 2010 Sixnet LLC Re verify your userid password and APN information Be sure to pay close attention all three of these items can be case sensitive and must be entered exactly in order to properly log into the cellular network Don t forget to click Apply if you make any changes Sixnet Inc A Red Lion Business CONNEC ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 2 3 3 Sixnet Technical Support If you have followed all of the instructions up to this point have satisfied yourself that you are not having an authentication problem are convinced that you have sufficient reception and your router is still not communicating then please call Sixnet Technical Support at 1 877 432 9908 Live support is available from 8 00 a m 4 30 p m CST If you Call after hour
247. lt settings e Click on the Factory Default menu item and the following window will appear Status Networking Services Advanced Restore Factory Defaults Restore Sixnet Wireless Toll Free 800 489 7781 el oO i a Fax 314 426 0007 4645 LaGuardia Drive Web wwwjbmetectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC To restore the Sixnet router to factory default settings click on the Restore button You will see the following warning message Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL P red lon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual The page at http IP Address 10000 says This action will cause the device to revert the Master Configuration file to default factory settings and reboot Your connection will be lost The default network settings could render the device incommunicable by any means other than a direct physical connection Are you sure you want to proceed e Click on the OK button to acknowledge the warning The Sixnet router is now reset back to default factory configuration settings Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Han busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 3 4 Firmware Update The
248. m Model Number Copyright 2010 Sixnet LLC o The download pop up window will appear o Click OK to save the file to your computer system o Ifyou are uploading the zipped stats file to the Sixnet FTP site or to a site of your choosing click on the pull down menu next to Select Delivery Method and choose FTP The display will change to reflect additional options for FTP ing the file to either the Sixnet FTP site or to a site of your choosing Status Networking Services Advanced Gather Stats Tornoe ves Include gwinx fog files Yes Select Delivery Method F TP E Destination Enter Project Name ME i Sixnet Wireless P ai Toll Free 800 489 7781 ie gtr 88 iban Elecirotruos Ue Fax 314 476 0007 4645 LaGuardia Drive i f sa Web www j gt melectronics com St Louis MO 63134 ALEAT www sbunet com Model Number Copyright 2010 Sixnet LLC o Ifyou are utilizing the Sixnet FTP site enter a project name such as a company name to designate the file on the FTP site o Click on the Gather button o Ifyou want to input your own FTP site click on the pull down menu next to the Designation field and choose User defined FTP site Sixnet Inc A Red Lion Business CONNE OR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The display will change to reflect the options availa
249. max fmdey 396 351 495 7681 580 046 60 035 ms Sixnet Wireless Toll Free 800 489 7781 formerly jim Electronics Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC The Source Interface offers the option of using different interfaces to send the ping through This is useful if you have a VPN Tunnel in place Testing the connection through the VPN Tunnel is required to verify connectivity through the tunnel e Choose the interface that the VPN Tunnel has listed for the Local Subnet end point i e if the Left Subnet is 10 100 100 0 24 and eth1 has 10 100 100 1 as its IP Address then choose Source Interface eth1 e Specify a host IP Address at the head end to ping through the tunnel e Click on the Ping button to see the result The Socket Test menu item will allows you to telnet to desire destination IP and Port address to verify the socket availability N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Home Ti Arp Cache Installed Firmware Yersion Feature Codes Firewall Rules Firmware Version Bumber Device Serial Number Serial Bumber System Processes Physical Interface Status System Services
250. mber A Jtility Dynamic DNS Installed Firmware Ver SN Proxy Settings firmware revision E SixView Manager GPS Settings Device Senal Numbe SSH Server unit serial system Logging Physical Interface Stal z TELNET Serwer Ethernet Interface Connection State IP ik Status usb 19 Ping Alive wn cht g etho 19 SN MP Agent Local Remote Station Cellular Interface Activation Connection IPA IO Transfer pppo Reg Home Enabled 166 1 Seg Cellular Uptime OD 1H 356M 4 75 Serial Si eaa aaia eee Disabled ad Display Config File Toll Free 800 489 7 781 Sixnet Wireless i Fax 314 426 0007 4645 LaGuardia Drive Web www sixnet com St Louis MO 63134 Send Email to Support 52nd gt model number Copyright 2012 Sixnet Inc e Click on the Serial menu item and the following window will appear Sixnet Inc A Red Lion Business CONNEC ONITOR COI red Mlle iiciocs 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Adm in Networking Services Advanced ModBus Serial Seral Table Properties Device Baud rate Data bits Parity Flow Control Stop bits Protocol Flo Local Remote Stations 10 Transfers Display Config Files Toll Free 800 489 7 781 Sixnet Wireless P Fax 314 426 0007 4645 LaGuardia Drive eae Cl i Web www sxnet com St Louis MO 63134 Sixnet l Send Email to Support 50700 Mal
251. me Cellular Uptime N A Unavailable N A Sdect auto update interva i Disabled Sinet Wireless 4645 LaGuardia Drive St Louis MO 63134 a model_number NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 19 19 ik Status wn Station and General Physical Link Layer Connection IP Address Signal Data Link and Application Layer HS PA Object Mapping Default Variation Toll Free 800 489 7 781 Fax 314 476 0007 Web www sknet com Send Email to Support 5200 gt Copyright 2012 Sixnet Inc T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual DNP3 Station and General Configuration Status Admin Networking Services Advanced DNP3 Station and General Configuration Define Station Properties i eee oN RAMb 4 Station Number Primary IP Address Bt Secondary IP Address Define General Properties Compatibility Mode Levd 2 E Level 2 On new event when Event Queue is full Discard Oldest Event E Discard Newest Event E Enable Unsolicited Responses Event Detection Rate Auto Max time events in queue after disconnect TCP W Enable Server only E Enable Red Time Data Trace Time Synchronization Physical Link layer DataLink and Application layer Object Mapping Default Variation Toll Free 800 489 7 781 Sixnet Wireless i Fax 314 426 0007 4645 LaGuardia Drive Web www smxnet
252. me for the whitelist in the space provided If the name of an existing whitelist is entered then you are in effect adding another member to the list of subnets defined by that whitelist group After you click the OK button you will see the entry added to the group in the stored display area under the Current Whitelist Groups heading This whitelist name will become available for selection in the other Firewall Rules sections where a whitelist can be selected Bellow screen will demonstrate an entry for Network1 with the 192 168 10 0 0 network address NOTE The first whitelist entry the default entry may not be deleted nor have its name changed but its subnet value may be changed Additional entries may be added edited and deleted as needed NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Firewall Whitelists General Behaviors Spinalni laie ede MO Restrictions Mj Current Yrhitelist Groups default 0 0 0 0 0 Networki 192 168 10 0 0 Individual Whitelist Definitions Name Subnet default 0 0 0 0 0 Networki 192 168 10 00 TT _ __ i Sixnet Wireless a Toll Free 800 489 7781 4645 LaGuardia Drive She Fax 314 426 0007 St Louis MO 63134 P 2 tiga Web www sixnet com Copyright 2010
253. mmended Setting Be advised that when connected via a Cellular interface the log file data collected will count towards your total data plan usage Select update interval Select the update interval to be used when auto update is enabled from provided drop down list Choices in seconds include e 5 e 15 e 30 e 60 Recommended Setting Be advised that when connected via a cellular interface the log file data collected will count towards your total data plan usage Download Click on Download button to send the entire Gwinx logfile logfile txt to your PC download directory Refresh Click on Refresh button to view the latest items being logged 3 6 6 10 Transniff Filter The Transniff Filter is only available on the R series Enterprise Routers This menu item allows you to set the filter values in similar format as the TCPDUMP filter for capturing traffic being seen by configured device on the Ethernet port Note This configuration screen is for devices that capture traffic between the ATM and transaction processing server for DVR text insertion Please contact WSBU Development Group Support staff for configuring this item e Click on the Advanced gt GwInx gt Transniff Filter menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 Industr
254. mote system logging to a remote system e TELNET Server Used to enable disable TELNET server e Ping Alive Used as a diagnostic tool for verifying connectivity between two hosts on a network e SNMP Agent Used to allow users to query the unit for information via SNMP e ModBus Used to allow acting as an I O concentrator for MODBUS devices if the IndustrialPro has been upgraded to RAM 3 1 6 Advanced The Advanced Tab is where you can configure the advanced features of the Sixnet router which includes IP Fallback IP Transparency Out of Band Management VRRP Expert Mode and GWLNX Protocol Conversion You have the capability of accessing some of the system files within the Expert Mode section The Advanced Tab is organized into seven 6 sections e IP Fallback Used to configure the Sixnet router for failover between interfaces for example Primary route on DSL Cable and secondary on Cellular e P Transparency Used to configure the IP Transparency the will pass the IP Address of the air card to the device connected to the Sixnet router on one of the Ethernet interfaces e Out of Band Met Used to configure the capability of remotely administrating a third party device connected via a serial cable on the Sixnet router e VRRP Used to configure the Sixnet router to share an IP Address and act as a failover for a third party router using Virtual Routing Redundancy Protocol Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL
255. n DNS Settings Provisioning Instal i Firi PPP Dial Backup Z PPP over Ethernet Static Routes TCP Global Setings Phy i Ethernet Interface Connection State IP Address Link Status ethO Up 192 168 0 1 ls eth Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppod ed Enabled T2 101 201 31 EVDO REV A a Ae eine Disabled rd Sixnet Wireless Toll Free 800 489 7781 formerly jbm Electronics Ph e Fax 314 426 0007 4645 LaGuardia Drive _ i me wars Web www jbmelectronics com St Louis MO 63134 Sat eR Ee WWW sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNECT MONITOR CC a red Lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual e Click on the Provisioning menu item If the cellular air card SIM is not recognized as a supported card then you the following warning pop up window will appear 4 Cellular Service provider must be selected before provisioning can proceed This may be accomplished on the Networking gt Cellular Connection gt Configuration screen e Click on the OK button to acknowledge the content Then you will see the following display Status Networking Services Advanced Cellular Provisioning Currently Selected Carrier None currently configured Current Selected Modem Novatel E725 Mobile Directory
256. n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Expert Mode Used to alter specific system files on the Sixnet router WARNING Do not use this method of configuration unless directed to do so by a support engineer from Sixnet If you do not fully understand how to make the changes and what effect those changes will have on the Sixnet router please contact a Sixnet technician e Gwlinx Used to configure the Protocol Conversion capability of the Sixnet router Protocol Conversion is a process used to convert legacy protocols to communicate over TCP IP NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 3 2 Status Tab IndustrialPro Series Router User Manual The Status Tab allows you to review the state of the router functions such as network connections interfaces system processes services running and system information It also allows review of the syslog update history and under diagnostic tools permits testing the connectivity through the use of ping and traceroute Status Home Aro Cache Feature Codes Firewall Rules system Processes system Senices system Information Update History Weil Wileniate pppo Sixnet Wireless formerly jom Electronics 4645 LaGuardia Drive St Louis MO 63
257. nced Home Arp Cache 7 Installed Firmware Version Feature Codes Firmware Version Number Firewall Rules Device Serial Number serial Number oystem Processes a Physical Interface Status e e Connection State IP Address Link Status syslog Up 192 168 0 1 Up Update History Up 199 168 14 Up wenuida menace Activation Connection IP Address Signal Strength ppp ed Enabled cee pelos Glee EVDO REV A at Hee ceria Disabled Fd Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics ama i Fax 314 426 0007 4645 LaGuardia Drive A J af bg Web www jbmelectronics com St Louis MO 63134 we ea E r G WWW Sixnet com Model Number Copyright 2010 Sixnet LLC a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual The columns represent the runlevel of the service your main concern is the column 3 shown in the table Any service with on in column 3 will automatically restart if the unit is restarted in any way for example by a reboot or an interruption in power e Click on the System Services menu item and the following window will appear status Networking Services Advanced System Services bos if ab adsl zoff bgpti Hes pimd J 0ff ripd soff sshd zoff wifi ort throughput test Oloff ipfalilback orf clock O off ahcpa J off crond rott ipsec J off osypfd Hpt snmpd Jof Vrrpd rorfz zebra zoff
258. net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Configure Display MODBUS forward stations e Configure Display local station information such as station name and station number e Configure Display serial ports e Configure Display MODBUS registers allocation Local Remote Station Status Adm in Networking Advanced SN Industrial Pro model_number A Jtility Dynamic DNS Installed Firmware Ver SN Proxy Settings firmware revision _ z SiW iew Manager GPS Settings Device Senal Numbe SSH Server unit serial System Logging Physical Interface Stal l p TELNET Server l Ethernet Interface Connection State IP ik Status usb Up 19 Ping Alive wn eth0 Up 12 SNMP Agent Local Remote Station Cellular Interface Activation Connection IPA 10 Transter pppo Reg Home Enabled 166 1 Forwarding Cellular Uptime OD 1H 24M 315 Serial si Caga a A Disabled hi Display Config File Toll Free 800 489 7 781 Sinet Wireless Fax 314 476 0007 A645 LaGuardia Dri A Web ixnet to abu ardia UNVe I eb WWW 5onetcom St Louis MO 63134 S M r t Send Email to Support 2nd Mal model number Copyright 2012 Sixnet Inc e Click on the Local Remote Station menu item and the following window will appear Sixnet Inc A Red Lion Business CONNEC ONITOR COI
259. net com Copyright 2010 Sixnet LLC o Enter the IP Address or URL to the FTP site of your choosing o Click on the Gather button NU Sixnet a red lon business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 3 6 Gather Stats The Gather Stats menu item allows you to create and zip up a report of pertinent information of the performance of the Sixnet router This information will include interface status network information such as netstat arp and routes IPSEC information if included firewall information and a copy of the syslog Click on the Gather Stats menu item and the following window will appear Status Networking Services Advanced Gather Stats include IPSEC Barf output Yes Include gwinx log files Yes Select Delivery Method Sixnet Wireless Toll Free 800 489 7781 foe merty jbm Blectronic PE Fax 314 426 0007 4645 LaGuardia Drive Web www jbimelectronics com St Louis MO 63134 www sbmet com Model Number Copyright 2010 Sixnet LLC To gather the stats of the Sixnet router e Choose whether you want to include IPSEC Barf output by clicking on the pull down menu next to Include IPSEC Barf output and choose No or Yes This is the output from several IPSEC commands that reveals the activity of
260. nk Status syslog Up 192 168 0 1 Up Update History Up 192 16811 Up wenuia ilenace Activation Connection IP Address Signal Strength pppo Ss ed Enabled r2 0T A013 EVDO REV A ate Rie Disabled Sixnet Wireless Toll Free 800 489 7781 formerly jbm Electronics a m Fax 314 426 0007 4645 LaGuardia Drive WF iT Web www jbmelectronics com St Louis MO 63134 he Ese i Www sixnet com Model Number Copyright 2010 Sixnet LLC NU a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the System Processes menu item and the following window will appear Status Networking Services Advanced System Processes a BEPMESEPSESESSESESESESSeSPSeeeeeoe2eeeeeerrels wWomnaas Owuvseaoaauwnwnoodcdconodononnanoninoninao0ocoooc orn lt on S ber lt STAT START TIME COMMAND S lt 11 03 0 00 kthreadd S lt 11 03 0 00 _ ksoftirqd 0 5 lt 11 03 0 03 events 0 5 lt 11 03 0 00 khe iper S lt 11 03 0 00 kb lockd 0 lt 11 03 0 00 ata 0 5 lt 11 03 0 00 ata_aux 5 11 03 0 00 pdf Lush 5 11 03 0 00 pdtiush Se 11 03 0 00 ksvapda0 S lt 11 03 0 00 aio O 5 lt 11 03 0 00 mtdb lockad S lt 11 03 0 00 mpceS3xx_spi 0 S lt 11 03 kerencd s lt 11 03 rpt iod 0 SN 11 03 3ffs2 ged meds SN 11 03 3ffs2_ gced_mtdl SN 11 03 3ffs2_gcd_mtd2 S lt 11 03 ksusp nd_usbad S lt
261. nother network For example if a device is attached to a LAN whose network address is 192 168 1 0 with a netmask of 255 255 255 0 then it can communicate directly with any other device on that network with a range of addresses of 192 168 1 1 through 192 168 1 254 with 192 168 1 255 reserved for broadcast An address outside of that range is on a different network which would need to accessed indirectly through a router and that router would be the gateway to the network on which the remote target device resides so to communicate with it would mean sending and receiving via the gateway device The address must be one within the valid range for the network on which the designated interface resides Enter Metric Enter a value for the route metric in this field Recommended value is 0 e Click on the OK button to populate the Static Routes screen Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Static Routes Interface Any Type ahg No host IP Address Subnet Netmask 10 100 100 10 Gateway Metric 192 163 120 0 Advanced Sixnet Wireless tormerly ibm Electronic 4645 LaGuardia Drive St Louis MO 63134 Model Number e Click on the Save button and the following pop up window will appear The page at http lt I
262. ns Specifies the maximum number of concurrent unauthenticated connections to the SSH server Additional connections will be dropped until authentication succeeds or the Login Grace Time expires for a connection Recommended value is 10 Allow Root Login Specifies whether root can log in directly to the SSH server Recommended setting is No e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says SSH Server settings saved and applied e Click on the OK button to acknowledge the content 3 5 6 SSL Connections The SSL Connections menu item allows you to configure the Sixnet router to either act as a Secure Socket Layer SSL Client to receive certificates or as an SSL Server to issue certificates The SSL Connections tab is sub sectioned into the SSL Client and the SSL Server SSL Client The SSL Client menu item allows you to configure the Sixnet router to be a SSL client and receive a certificate of authorization from an SSL server to authenticate connections for secure communications Click on the SSL Client menu item and the following window will appear Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Advanced SSL Client SSL Client Stopped
263. nstead Select Protocol Choose the protocol for the type of data you want to allow Options are TCP or UDP Source network via whitelist Select a whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking Firewall gt Subnet Whitelist Rules screen Add Service Access Rule Stating Port Ending Port Interface Sdect Protocol Source network via Whitelist e Click on the OK button to populate the Service Access Rules screen NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red If9n business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Firewall Service Access Rules Start Port End Port Interface Protocol Source Whitelist 7785 7785 AJl Untrusted TCP default a080 8081 pppo TCP defauh Sixnet Wireless Toll Free 800 489 7781 or meriy jbm Blectronics Fax 314 476 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window wi
264. ny route by selecting Yes or No from the provided drop down list When set to Yes the route will take effect when a network change event up down occurs on any interface For example if the configured interface is ethO and the pppO interface becomes active then the route will be reapplied to etho When set to No the route will take effect only when a network change occurs on the configured interface For example if the configured interface is eth1 then the route will be assigned only when eth1 has a network change to an active state NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Select Route Type Select the type of route to be created by choosing one of the available options from the provided drop down list Choices include e Host to create a route to a specific device This will require setting the Target IP Address and Gateway parameters e Network to create a route to a remote network This will require setting the Network IP Address Netmask and Gateway parameters Host Configuration Static Route Enter Target IP Address Enter the IP Address of the destination host to which the route should be created Enter Gateway Enter the IP Address of the gateway for the specified host or network A gateway is a device typically a router used to gain access to a
265. o maintain their leases Default 14400 4 hours Enter Maximum Lease Time seconds Specify the amount of time in seconds that the DHCP Server will allow clients to maintain their leases Default 86400 24 hours Enter Minimum Lease Time seconds Specify the amount of time in seconds that the DHCP Server will allow clients to maintain their leases Default 3600 1 hour DHCP Servers The DHCP Servers section allows you to configure one of the Ethernet ports to be a DHCP server and issue IP Addresses to systems connected to that network segment Since both the ethO and eth1 are configured in the same manner we will only cover the configuration of eth0O NOTE If the interface is not enabled or has been set to obtain its addressing parameters via DHCP this option will be forced to No and disabled until the interface is both enabled and set to use a static IP address e Click on the pull down menu at the Enable DHCP for eth0 e Click on Yes and the display will expand to reveal the configuration fields DHCP Servers Enable DHCP for eth0 Enable Default Gateway for eth0 Saeed ladle tele 192 168 0 2 Sales lee 192 168 0 254 Enable Default Gateway for eth0 Description Provide Default Gateway IP Address to DHCP Client NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5
266. o Support 5end ETL Copyright 2012 Sixnet LLC Select which type of Provisioning you will be using There are six 6 different types of provisioning e OMA DM Automatic Activation Provisioning Vision IP only Static IP only Static Vision alternate Datalink only Datalink Vision alternate i s sixnet Inc A Red Lion Business a red ln business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual Static IP only Static Vision alternate Datalink only Datalink Vision alternate Provisioning for Vision IP only Static IP only If you are you using Vision IP only or Static IP only provisioning you will enter the following information e Enter the SPC Unlock code provided by your cellular carrier at time of activation e The Mobile IP mode should always be set to Mobile IP preferred e Set the Sync system time to cellular network time to Yes e Enter the ESN which can be found in the upper window next to Detected ESN e Enter the MDN provided by your cellular carrier e Enter the MSID provided by your cellular carrier e When all of your information is correctly entered click Apply For more information regarding a specific field refer to the yellow Help button to the right side of the screen NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake
267. om 74 125 95 105 30 hops max 35 byte packets 64 Sub 66 174 193 myvew com 66 174 1935 64 53 296 ma 71 525 ma 67 737 ms 127 3ub 66 174 193 wyyew com 66 174 193 127 71 907 ma 75 806 me 75 7650 ms 217 8ub 69 83 133 wyvew com 69 83 1535 217 63 699 ma 99 440 ms 79 922 ms 95 5ub 66 174 67 myveuw com 66 174 67 965 79 935 ma 75 434 ms 59 942 ms 160 sub 66 174 64 myv2eu com 66 174 64 150 75 940 ma 79 425 ma 63 9355 179 sub 66 174 64 myv2eu com 66 174 64 179 74 279 ma 65 164 ms 55 9242 205 3ub 69 835 130 0y7v2u com 69 8353 150 253 50 120 ma 79 365 ma 63 906 Te 4 ar5 CHIl gblx net 64 211 60 5 107 944 ma 67 372 ms 103 941 ms tel 1 10G ar4 CHIz ghblx net 67 16 1352 214 07 922 ma 87 394 ma 79 921 74 125 49 145 74 125 49 145 107 953 ms 91 382 mas 79 920 ms 209 685 254 122 209 685 254 122 79 939 ms 209 685 254 130 209 865 254 130 91 35 724 194 232 141 72 14 232 141 176 732 me 99 367 ms 105 920 ms 209 605 241 355 209 055 241 355 103 941 ma 107 433 ms 209 85 241 27 209 085 2441 209 65 240 45 209 55 240 45 119 474 me fee lew239 19S 72 14 239 193 119 754 iw in 105 1e6e100 net 74 125 95 105 102 699 ms 107 417 ms 103 909 ms Sixnet Wireless Toll Free 800 489 7781 Fax 314 426 0007 formerly jbm Electronics Oe ia e 4645 LaGuardia Drive S X n t Web www jbmelectronics com St Louis MO 63134 Te Model Number Copyright 2010 Sixnet LLC It is recommended to start with a locally accessible IP address to confirm
268. on If it is displaying bars of signal that flash every 2 seconds then signal is available to the tower but a cellular connection has not been established SN6000 units Observe the Signal LED as shown GND PWR our IN Diversity Antenna we hice oS www sixnelLcom rir iPir A 1 i _ Ethernet RS232 eo SN 6601 evoo Power WAN fas G RS232 Signal gt IXNE l www sixnet com Power WAN cl a g ee Senet i aU Sixnet Inc A Red Lion Business i 0 a red Lory business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual ON Excellent signal strength greater than 69 dBm Medium Medium Every 600ms 89t0 80d8m 600ms 89 to 80 dBm Slow Slow Every 1200ms 99t0 90d8m 1200ms Slow Every 1200ms 99t0 90d8m 99 to 90 dBm Tore a No signal available or signal strength is below 100 dBm Signal Fast e r r 300ms 79 to 70 dBm FLASH 2 3 1 Minimal Reception On occasion you can find yourself in a situation where you have just enough signal to be able to communicate with the cellular tower and obtain an IP address but not enough reception to be able to sustain a viable connection If your cellular card is using dynamically assigned IP addresses you can determine if you are in a situation like this by watching the Cellular Interface field in the screen below Status Ethernet Interfac
269. on and the following pop up window will appear Operation Succeeded OK e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 6 6 5 Manage Configuratons The Manage Configurations menu item allows you to install or delete Gwinx configuration files that already reside on Sixnet IndustrialPro or R Series router devices e Click on the Advanced GwInx gt Manage Configurations menu item and the following window will appear Status Admin Networking Services Advanced _ Manage Gwinx Configuration Files lt as seede aei E None Selected w Cancel Install Delete Toll Ha I E r E 7 1 3 i i EP E Sixnet Wireless Ph a 4645 LaGuardia Drive web SX 00 St Lows 031z l 7 D ae Send Email to Support Model Number Copyright 2012 Sixnet LLC Select Gwlnx Configuration File Select a gwlnx configuration file on the remote unit to install or to delete Required Warning Deleting the unit cfg or unit xml file may result the gwlnx application from not running on the next restart Recommended Setting Do not install or delete files unless directed by WSBU Development Group Support staff e Click on the Install or Delete button and one of the following pop up window
270. on the OK button to acknowledge the content 3 4 6 PPP over Ethernet The PPP over Ethernet menu item allows you to configure a connection by being able to connect to a DSL or cable modem e Click on the PPP over Ethernet menu item and the following window will appear N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced PPP over Ethernet Enable PPPoE No Sixnet Wireless oa Toll Free 800 489 7781 for merty jbm Electronics Fax 314 426 0007 46451 aGuar dia Drive VAY i Weh www jbmelecironics com St Louis MO 63134 LEAS www sbaet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu at the Enable PPPOE field e Click on the Yes and the display will expand to reveal the fields for configuring the PPP over Ethernet Status Networking Services Advanced PPP over Ethernet Enable PPPoE vesz Select interface eho Enter User Name Enter Password Confirm Password Select DNS Method Use Default Route Dial on Demand Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electror Fax 314 476 000 7 4645 LaGuardia Drive Web www jomelectronics com St Louis MO 63134 Wwww spanet com Model Number Copyright 2010 Sixnet LLC Select
271. on the wireless interface Internal Port Enter the IP Port number to be used as the Internal Port for redirection This is the port that incoming connections are transformed to in order to reach a listening process on this same port on the device behind the specified Internal Interface Protocol Select either TCP or UDP as the protocol for which to apply the redirection from the drop down list provided e Click on the OK button to populate the Port Re directs screen Enable port r cirecting Yes Enable traffic restrictions No Z d External Port Internal Port Protocol Add 6080 80 TCP eae Sixnet Wireless nn Toll Free 800 489 7781 E T Glectrorics Fax 314 426 0007 1645 LaGuardia Drive Web www jbmetecti onics com St Louis MO 63134 Www sixnet com Model Number Copvriaht 2010 Sixnet LLC NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Enable traffic restrictions Select Yes to restrict traffic to a device beyond the Gateway device the one being configured When this feature is enabled new fields will appear to allow selection of the restriction mode and a table into which multiple entries can be entered Each entry will specify the network IP address range to which the restrictions will be applied Enable pon re direct
272. onnection before closing down the link Default is 720 Advance Setup Select Yes to modify advanced SSL options The display will expand to reveal the advance setup fields Status Adm in Networking Services Advanced SSL Client SSL Client Stopped Enable SSL Activity Log Levd Wait for Connection sec Idle Timeout min Eri Advance Setup Bind Interface for accepting TCP Connections Bind Interface for outgoing SSL Connections FeAl sag TIEA RC4 MDS RC4 SHA ALL ADH aNULL eHULL LOW EXP SSLyv2 RC4 R5A HIGH HE DIUM mi Do not use certificate Keep Alive behavior Mone x Label TCP Listening IP TCP Listening Port SSL Destination IP SSL Destinatio Add Toll Free 800 489 7 781 Sinet Wireless i Fax 314 476 0007 a a s p T z 4645 LaGuardia Drive i Web www snet com St Louis MO 63134 Si xXne f l j Send Email to Support 200 Mal model number Copyright 2012 Sixnet Inc Bind Interface for accepting TCP Connections This will restrict the unencrypted listening socket to allow connections coming into the specified interface only Recommended setting is Any Bind Interface for outgoing SSL Connections This will restrict the encrypted socket to initiate connections out the specified interface only Specifying an interface here may conflict with policy routing however it may be required in a GRE VPN or other tunneled environment Please consult wit
273. our environment has the potential to significantly impact our ability to receive a good quality cellular signal You should be aware that it is possible to stand in the parking lot of a building and have perfect reception but walk just 10 feet inside a concrete and steel building and have absolutely no reception at all The important thing to understand is that in many many instances it is not the cellular network that causes reception problems but the environment in which we place our cellular devices Important Note about Cellular Antennas For this reason Sixnet strongly recommends the use of external antennas when implementing cellular data It is often the key to a successful implementation Consult your Sixnet representative if you have questions about the appropriate use of external antennas Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 2 3 Verifying IP Connectivity First check to make sure that your card is connecting to the cellular network and obtaining an IP address Navigate to the GAU screen shown below Status Admin Networking Services Advanced device_family Administration Utility Installed Firmware Version firmware revision Device Senal Number serial number System Uptime OD OH 5M 35S sical Interface Status Connection State IP Addres
274. ow Redirect DMZ NAT etc Add Subnet Blacklist Rule R ele ieee 15 63 95 04 NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the Subnet Blacklist Rules screen Status Networking Services Advanced Firewall Subnet Blacklist Rules Subnet 185 63 95 0 24 Sixnet Wireless Toll Free 800 489 7781 tor marly jbm Electronics Fax 314 426 0007 4645 LaGuardia Drive Web www jbmetectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Subnet Whitelist Rules The Subnet Whitelist Rules menu item allows you to define a single IP Address or
275. poration All rights reserved Cco lt Users s Some Username gt ping 192 168 1 1 Pinging 192 168 1 1 with 32 bytes of data Reply from 192 168 1 1 bytes 32 time 15ms TTL 1248 Reply from 192 168 1 1 bytes 32 time ims TTL 128 Reply from 192 168 1 1 bytes 32 time ims TTL 128 Reply from 192 168 1 1 bytes 32 time ims TTL 128 Ping statistics for 192 168 1 1 Packets Sent 4 Received 4 Lost H loss Approximate round trip times in milli seconds Minimum ims Maximum 15ms Average 4ms C Users Some Username gt This shows the connection is up and functioning 1 3 Access Sixnet Webserver ared Hn business 331 Usners Road Baliston Lake NY 12 Open a web browser and enter the following in the address bar CONNECT MONITOR CONTROL 16 IndustrialPro Series Router User Manual METHOD 1 WAN ethO http 192 168 0 1 10000 METHOD 2 LAN eth1 http 192 168 1 1 10000 e You will receive a login pop up screen XP Authentication Required 9 Enter username and password for gateway at http lt IP Address gt 10000 User Name Pe Password C Use Password Manager to remember this password Co Cen Vista Windows 7 Q A username and password are being requested by http 10 200 200 1 10000 The site says gateway User Name Password Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red If9n business 331 Ushers Road Ballston Lake NY 12019 T
276. r Configuration File Default Import file handling Replace Select GAU Master Configuration File C Users michaelm SIXNE T1O Desktop config xml tt onfiguration update is in progress he process can take several minutes to complete Do not disconnect power during the process Do not exit this page ou wil be notified here when the process is complete please standby Sixnet Wireless formerly jbm Electronics 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7731 Fax 314 4276 0007 Web www jbmelectronics com www sixnet com SN 6621 Copyright 2010 Sixnet LLC Once completed a list of changes will appear in the message window and a pop up window will appear to request a reboot The page at http lt IP Address gt 10000 says Click OK to reboot the device now a e Click on the OK button The next pop up window will inform you that the actions you are taking will reboot the device and will ask you to confirm your actions The page at http lt IP Address gt 10000 says This action will cause the device to reboot Your connection will be lost Incomplete or incorrect network settings could render the device incommunicable Are you sure you want to proceed Conc ED NU Sixnet Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User
277. r Information Connection State IP Address Link Status Lp 192 168 0 1 Up Update History Up 192 168 1 1 Lp verwar menace Activation Connection IP Address signal Strength pppd z ed Enabled f2 107 2017 31 EYDO REV A ale ei Disabled Ad Wd Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics a Fax 314 426 0007 4645 LaGuardia Drive _ ie waor Web www jbmelectronics com St Louis MO 63134 i eh Fr n www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNEC ONITOR COI NU 5 red in business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Interface Information Link detected yes Link detected yes Link encap Ethernet HWaddr 00 60 DA 02 44 95 inet addr 192 1668 0 i Beast 192 168 0 255 WMask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packet2 1226 errors 0 dropped 0 overruns 0 frame 0 TX packets 1241 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 180057 175 8 Kb Base address 0x8000 TX bytes 961630 939 0 Kb Link encap Ethernet HWaddr 00 60 DA 02 44 96 inet addr 192 1668 1 1 Bceast 192 168 1 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1S00 Metric 1 RX packets 648 errors 0 dropped O0 overruns 0 frame 0 TX packets 638 errors 0 dropped 0 overruns 0 carrier 0 collizions 0 txqueuelen 1
278. r SSH Port 2022 Enter SSH Port Enter the IP Port number to be used for SSH access when SSH access has been enabled The port chosen will be redirected locally Connections on this port number will not reach the device behind the specified Internal Interface Recommended setting is 2022 All SSH traffic will be redirected locally to port 22 automatically This N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual behavior is built in and not configurable Incoming connections on port 22 will reach the device behind the specified Internal Interface NOTE The SSH Server settings need not be altered to support the specification of a port other than 22 here Allow access to Gateway Administration Utility Select Yes to allow access for incoming TCP Port 10000 connections to the GAU on this device Selecting No will allow the connection through to the router behind the selected interface Recommended setting is Yes Enter GAU Port Enter the IP Port number to be used for GAU access when GAU access has been enabled The port chosen will be redirected locally Connections on this port number will not reach the device behind the specified Internal Interface Recommended setting is 10000 All GAU traffic will be redirected locally to port 10000 automatically This
279. r systems such as point to point serial links may decide MTU at connect time A larger MTU brings greater efficiency because each packet carries more user data while protocol overheads such as headers or underlying per packet delays remain fixed the resulting higher efficiency means a slight improvement in bulk protocol throughput A larger MTU also means processing of fewer packets for the same amount of data In some systems per packet processing can be a critical performance limitation However this gain is not without some downside Large packets can occupy a slow link for some time causing greater delays to following packets and increasing lag and minimum latency For example a 1500 byte packet the largest allowed by Ethernet at the network layer and hence over most of the Internet ties up a 14 4k modem for about one second Recommended Setting 1500 Interface Aliases Sub Interfaces Sub interfacing is essentially the segmenting of a single wire or port into multiple IP networks Instead of subnetting and routing you can create a sub interface and then set it up as you would a standard Ethernet interface To configure a sub interface e Click on the Add button and the following pop up window will appear e Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Ad
280. racter is Connection closed by foreign host Test Complete Sixnet Wireless 7 Toll Free 800 489 77381 4645 LaGuardia Drive Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copyright 2010 Sixnet LLC Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced TCP Socket test with Telnet Sahel aie Eee oe ea aa 92 168 10 101 Enter Destination Port Address to test Bil Telnet Results for 192 168 110 101 5001 telnet Unable to connect to remote host No route to host Trying 192 168 10 101 35091 Test Complete Sixnet Wireless Toll Free 800 489 7731 4645 LaGuardia Drive Fax 314 426 0007 St Louis MO 63134 Web www sixnet com Copynght 2010 Sixnet LLC NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The Speed Test menu item will allows you to test the bandwidth and latency of a unit s cellular connection Note Only for testing units with an activated cellular connection Status Admin Networking Services Advanced Home RAM SN 6821 Administration Utility Arp Cache Installed Firmware Version Feature Codes A 7
281. ransmit Receive and Ground pins Yes if dealing with a port that has all signal pins present Number Of Missed Polls Allowed This option allows you to set the maximum number of missed RTU polls before reinitializing all the internal memory and buffer conditions If a packet is transmitted out the serial port and no response packet is received this is counted as a missed poll and data content is not evaluated Recommended Setting 0 To disable this action and any other value is upon your environment requirements TCP UDP Port Configuration Socket Type Select the Socket Type you desire to have for Serial IP communication from the drop down list Recommended Setting Socket Type you desire to have for this communication UDP If this option is selected the device will act as a UDP Connectionless and listening on the configured Listening IP Port for connection from the client Socket Type eS TCP UDP Independent Activation No Peer IP Address 0 0 00 NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual TCP Client If this option is selected the device will act as a TCP Client and connects to the host processor once the serial port becomes active TCP UDP Port Configuration Seen CP Client TCP UDP Independent Activation TCP Headers Host IP Port Be
282. rewall Rules Mevice Serial Number Policy Routing Table Serial Number standard Routing Table oystem Processes System Services Physical Interface Status sical Interface Status Syam Mieiie ar Connection State IP Address Link Status Syslog Up 192 168 0 1 Up Update History Up 199 168 11 Up vena mernace Activation Connection IP Address Signal Strength pppo ed Enabled SON ee EVDO REV A esc Disabled rd Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics i 2 Fax 314 426 0007 4645 LaGuardia Drive J wrriotr Web www jbmelectronics com St Louis MO 63134 fi ea Ee S Www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNEC ONITOR CON a red Eider business 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the Policy Routing Table menu item and the following window will appear Status Networking Services Advanced Policy Routing Table ip tule show from all lookup local from all lookup main from 127 0 0 1 lookup lo from 192 168 0 1 lookup ethd from 192 168 1 1 lookup ethi from all lookup main from all lookup default oO ee ee oe E Ww Wee pe pe Ny hf Ww t ip route show table lo 27 0 0 0 6 dev lo scope link rc i27 0 0 1 tt ip route show table ethd 192 1685 0 0 24 dev ethQO scope ere 192 168 0 1 ip route showu table ethi 24 dev ethi scope route s
283. rialPro Series Router User Manual e Click on the Predefined Interface Names menu item and the following window will appear Status Admin Networking Services Advanced Predefined logical Interface Names Delete Sixnet Wireless pa Toll Free 800 489 7781 for mer iby Electroric 4645 LaGuardia Drive Web www Jbmelectronics com St Louis MO 63134 Www sponet com Model Number Copyright 2010 Sixnet LLC e Click on the Add button to add a named interface and the following pop up window will appear Add Predefined Interface Enter logical Interface Name es Enter logical Interface Name Enter the name of the interface to be used for the logical interface For example tuno gre4 ppp100 etc NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the Predefined logical Interface Names screen Status Admin Networking Services Advanced Predefined logical Interface Names Sixnet Wireless Toll Free 800 489 7781 i Fax 314 426 0007 Iy ibm Electirori 1645 LaGuardia Di Web wwwjbmelectronics com St Louts MO 63134 www sbuet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000
284. ries Router User Manual Tunnel Name Enter some descriptive text in this field as an aid in identifying it The value must not contain spaces Enable Tunnel Specify whether you want this tunnel to connect to its remote peer now and after any reboot Tunnel Type Tunnel Type controls the initial mode of the tunnel at startup The options given to IPSec will be Client auto start Server auto add Dynamic auto route For more information please consult an IPSec user guide on aspects of these specific modes Tunnel Negotiation Mode Your Sixnet router defaults to Main mode ISAKMP negotiation When using dynamic or DHCP issued IP addresses for example with cellular cards some remote devices may require the use of Aggressive Mode ISAKMP Negotiation Should you encounter this situation you can perform aggressive mode ISAKMP negotiation by changing this parameter from Main to Aggressive ISAKMP NOTE Aggressive Mode ISAKMP negotiation is considered less secure than Main Mode Therefore you would be well advised to only use Aggressive Mode negotiation if the remote device requires it Otherwise it is preferable to use Main mode where ever possible Phase 1 Encryption IKE Specifies the Phase 1 Internet Key Exchange IKE cryptographic algorithm to be used Possible options are AES AES256 or 3DES Phase 1 Authentication Select the type of authentication you want to use for phase 1 IKE Possible options
285. ro Series Router User Manual NOTE This option will only be necessary if the SixView Manager Client is required to communicate through a configured IPSEC GRE or IPIP tunnel Enter Rapid Check in Interval Enables device to send Cell modem RF status information at very short intervals This feature is only supported by SixView Manager Servers running 1 22 or later version server software NOTE Each Rapid RF check in will produce about 1300 bytes of data Setting this value to 15 seconds will generate about 7 4MB of data a day 224 6MB every 30 days This amount is addition to any other data the unit might be transmitting receiving Enter 0 if you are not using this feature on a Sixnet SixView Manage server Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Disable SixView Manager Client e Click on the pull down menu at the Enable SixView Manager Access e Click on No and the display will retract Status Networking Services Advanced SixView Manager Current Client Status DISABLED Next Checkin NIA Reporting to wew myogmu com Enable GMU Access No Sixnet Wireless E Toll Free 800 489 7781 formerly ibm Blectroei Fax 314 476 0007 1645 LaGuardia Drive Web www jbmetectronics com St Louis MO 63134 WWww sicnet com Model Number Copyright 2010 Sixnet L
286. rope GMT Saskatchewan Canada Skopje Europe GMT 0 Yukon Canada Sofia Europe GMT O Amsterdam Europe Stockholm Europe GMTO Andorra Europe Tallinn Europe Greenwich Athens Europe Tirane Europe HST Belfast Europe Tiraspol Europe Hongkong Belgrade Europe Uzhgorod Europe Iceland Berlin Europe Vaduz Europe Iran Bratislava Europe Vatican Europe Israel Brussels Europe Vienna Europe O N Sixnet a red Hon business CONNECT MONITOR CONTROL T 1 518 877 5173 F 1 518 877 8346 Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 IndustrialPro Series Router User Manual Jamaica Bucharest Europe Vilnius Europe Japan Budapest Europe Warsaw Europe Kwajalein Chisinau Europe Zagreb Europe Libya Copenhagen Europe Zaporozhye Europe MET Dublin Europe Zurich Europe MST Gibraltar Europe Alaska US MST7MDT Helsinki Europe Aleutian US NZ Istanbul Europe Arizona US NZ CHAT Kaliningrad Europe Central US Navajo Kiev Europe East Indiana US PRC Lisbon Europe Eastern US PST8PDT Ljubljana Europe Hawaii US Poland London Europe Indiana Starke US Portugal Luxembourg Europe Michigan US ROK Madrid Europe Mountain US Singapore Malta Europe Pacific US Turkey Mariehamn Europe Samoa US UCT Minsk Europe UTC Monaco Europe e Scroll down and up until you locate the Time Zone you need e Click on the selected Time Zone to populate the T
287. rs Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 5 9 Ping Alive Ping is a diagnostic tool used for verifying connectivity between two hosts on a network It sends Internet Control Message Protocol ICMP echo request packets to a remote IP address and watches for ICMP responses Click on Ping Alive tab as shown below to enable Ping Alive option Status Admin Networking Services Advanced Administration Utili Dynamic DNS Installed Firmware Vers Six View Manager Firmware Version Number _ _ GPS Settings SSH Server Device Serial Number Serial Number System Logging TELNET Server Physical Interface Stat Ethernet Interface Connection State ip 9 nue ik Status usb Up 19 SNMP Agent Win eth0 Up 19 Cellular Interface Activation Connection IP Address Signal Strength pppo Unavailable Enabled 166 130 37 97 UMTS 91 he ene eE auaa IA Disabled v Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7781 Fax 314 426 0007 Web www sixnet com Copyright 2010 Sixnet LLC e Click on Ping Alive tab as shown above to enable Ping Alive option Status Admin Networking Services Advanced Enable Ping Alive Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7781 Fax 314 426 000 7 Web www sixnet com Copyright 2010 Sixnet LLC e Select Yes to Enable Ping Alive
288. rt 2 Connect Timeout Toll Free 800 489 7761 Fax 314 476 0007 Sixnet Wireless Web wu t 4645 LaGuardia Drive eb www sixnet com St Louis MO 63134 Send Email to Support Model Number Copyright 2012 Sixnet LLC TCP UDP Independent Activation This option determines if the TCP IP port of the device will accept data before the remote side Serial Port is active At least one of the two sides in the configuration must be set for Independent Activation If neither side is set then the device will not accept data This function provides integrity for the device by preventing data from being accepted until it can be delivered successfully A TCP Server set to Yes will listen even if the serial side is not considered connected If set to No it will not listen for a connection until the serial side is considered connected A TCP Client set to Yes will always attempt to connect to the configured destination IP even if the serial side is not connected or active If set to No it will attempt a connection only when the serial side is first considered connected Recommended Setting Yes for Servers No for Clients Peer IP Address Enter the peer IP Address into this field This is Required for UDP communication This specifies the Peer IP address and if set to 0 0 0 0 any remote IP can send UDP packets to our peer port and return packets will be sent back to the IP of the last host that sent us a message Packets cannot be sent until one i
289. rts under Local Address with a state of LISTEN are in use SSL Destination IP Enter the IP or Domain Name of the SSL server to which you would like to connect SSL Destination Port Enter the Port number of the SSL server to which you would like to connect Click on the OK button to populate the SSL Client screen Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced SSL Client O O OO a gaL Client Jtopped Enable SSL Activity Log Level Wait for Connection sec Idle Timeout min Bal ele TES ow Bind Interface for accepting TCP Connections r Bind Interface for outgoing SSL Figg Connections Sfl RCA HDS RCA JHA ALL ADH aNULL eNULL LOW EXP 39Lv2 RC4 RSA HIGH 4EDIUM scie Do not use certificate Keep Alive behavior None Label TCP Listening IP TCP Listening Port SSL Destination IP SSL De Add S Toll Free 800 489 7781 Fax 314 426 0007 Sixnet Wireless E Web www sixmet con 4645 LaGuardia Drive i 6313 F T L PT OELE Send Email to Support 5end BETI Gateway R3300B G Copyright 2012 Sixnet Inc e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says a SSL Cli
290. s P Toll Free 800 489 7781 Sixnet Wireless Fax 314 476 0007 4645 LaGuardia Drive eae Web www sixnet com St Louis MO 63134 Sixnet Send Email to Support 5600 Man Model Number Copyright 2012 Sixnet Inc Enable Auto update Select Yes to enable automatic updating of the CLI status file The update interval can be selected using the Select Update Interval provided immediately below this control Manual updating Refresh is disabled while auto update is in effect Recommended Setting Be advised that when connected via a Cellular interface the log file data collected will count towards your total data plan usage Select update interval Select the update interval to be used when auto update is enabled from provided drop down list Choices in seconds include e 5 e 15 Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e 30 e 60 Recommended Setting Be advised that when connected via a cellular interface the log file data collected will count towards your total data plan usage 3 6 6 8 GWLNX Status The Gwlnx Status menu item allows you to view the Gwlinx process ID and ability to restart the application by selecting the process ID from the provided drop down list The Refresh button will refresh the process ID if the Gwlnx application has been restarted
291. s 192 168 111 1 192 168 0 1 Ethernet Interface usb etho Link Status Down Up Cellular Interface Activation Connection IP Address Signal Strength N A Searching Enabled N A No Service 110 Cellular Uptime Connecting Cad Wen EREA Disabled i Toll Free 800 489 7781 Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 model number Fax 314 4276 000 7 Web www siknet com g gt a gt K T eT Send Email to Support 5200 Mal Copyright 2012 Sixnet Inc If your screen looks similar to the one shown above you are having signal reception difficulties As you will notice the card is neither connected to the cellular network nor has it been able to obtain an IP address from the network You can further verify this condition by examining the LED signal meter R3000 M1000 A2000 units Observe the signal meter in the middle of the front panel of the device as shown in the picture below NS a red lion business Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual LED Signal Meter Si X n Tvs DTE an POWER i If the top and bottom LEDs are flashing the device is not receiving sufficient signal from the cellular towers in order to be able to connect to the network Typically 2 3 LEDs of reception are a minimum requirement for a sustainable connecti
292. s please provide the agent will your contact information and a detailed description of your problem and we will respond to you the following day or Monday if you phone after 4 30 pm Friday We will be happy to assist you in getting your router operational When submitting a support question it is most helpful to have a GatherStats from the unit in question Please obtain one from the Admin gt GatherStats screen Choose the Download Option and save the resulting file to your PC You may attach it to an email to support sixnet com describing your issue NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual oo BA cl 2 8 B aa a m r MEd d 3 1 Gateway Administration Utility GAU Introduction 3 1 1 Organization The Sixnet Gateway Administration Utility GAU is comprised of five major sections e Status e Admin e Networking e Services e Advanced By clicking the tabs along the top of the interface each of the major sections may be accessed as shown below Status Admin Networking Services Advanced Installed Firmware Version Firmware Version Number Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address Link Status ethd Up 192 168 0 1 Up eth1 Up 192 168 Up Cellular Interface Activation Connection
293. s CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Forwarding Status Admin Networking SN Industrial Pro model_number A Dynamic ONS Installed Firmware Ver SN Proxy Settings firmware revision SixView Manager GPS Settings Device Senal Numbe SSH Server unit serial System Logging Physical Interface Stal Ethernet Interface Connection State IP usb Up 19 Ping Alive etho Up 1 TELNET Server g SNMP Agent Cellular Interface Activation Connection pppo Reg Home Enabled Cellular Uptime OD 1H 31M 485 IP A 166 1 Sdect auto update E A Disabled Sixnet Wireless 4645 LaGuardia Drive St Louis MO 63134 Sixnet Advanced Jtility ik Status wn Local Remote Station IO Transfer Forwarding Serial Display Config File Toll Free 800 489 7781 Fax 314 4276 000 Web www smnet com Send Email to Support o5 Mal model number e Click on the Forwarding menu item and the following window will appear NU a red lion business Sixnet Inc A Red Lion Business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 Copyright 2012 Sixnet Inc 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced ee 0 0 0 Forward Table Properties Station Number Forward Station Number Type Address Port
294. s MCE MCE795 w rd Enable Modem Auto Detection ES i Vievy Change Advanced Options TES j Enter Dial String Note Must ba in AT command farmat SIM Unlock PIN Code KLEE Note Sea help link for details id E Use Default Route TES Y rd 5 Cellular Network Speed RF Radio Region Choose Connection Behavior Cellular MTU f fa Rage 3 4 Maximum Receive Idle Time eee see Yes Ei Enable Dial Holdoff No Ei Ei Toll Free 800 489 7781 J Fax 314 476 0007 a Web www sixnet com Auto add SNAT rule Sixnet Wireless 4645 LaGuardia Drive SE n PLETE Send Email to Support 52nd Mail Sixnet Inc A Red Lion Business NNEC ONITO NTROL 8 877 8346 a red Hiden business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 151 IndustrialPro Series Router User Manual You now see the following options available Enter Dial String field The Dial String field is where you would input the string of characters the air card SIM uses to dial into the carrier s network NOTE This will be automatically filled in if the air card SIM is recognized by the Sixnet router To enter the Dial String Click on the field next to Enter Dial String e Type in the string of characters issued by the carrier Cellular Network Speed There are three choices for the setting Auto High and Low e Click on the drop down menu next to the Cellular Network Speed e Select
295. s Router User Manual The full display with common parameters included is shown below Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Hon business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Add IPSEC Tunnel Tunna Name Reg uired Enable Tunnd Tunnd Type Tunnag Negotiation Mode Phase 1 Encryption Phase 1 Authentication MDS BiH eee Reel Group 2 1024 bits Phase 1 ISAKMP Time minutes E ee Character string Required Loca Peer ID Remote Peer ID ay mo d Phase 2 Auth Type meg Phase Encryption Phase 2 Authentication Phase ISAKMP Time minutes No SES M Restart v peeaire aE E e Restart 7 Use Perfect Forward Secrecy DPD Interva seconds Bil DPD Timeout seconds lt a va ae ct Li bo a4 dE 1J L Gh bo Local Public IP Address Local Source IP Loca Gateway IP Address Eol Be eee ee 0O 24710 100 200 0 2 4 Remote Public IP Address Remote Gateway IP Address FP See ee ee elo 10 10 0 24 Cancel OK XI Ie C Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Lior business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the IPSEC screen Status Networking Services Advanced IPSEC Enable P
296. s received first to learn the remote peer s IP If set to a specific IP then packets will be sent to this IP only Recommended Setting lt 0 0 0 0 gt to allow any IP to send packets to the peer port number Peer IP Port Enter the peer Port number into this field This is Required for UDP communication Recommended Setting Consult your network administrator for UDP application destination port number Client IP Port Enter the client IP port number into this field This is Required if the peer ip address is set to a specific IP then packets will be sent to specific IP at this client IP port number only Recommended Setting lt 0 0 0 0 gt to allow any IP to send packets to the peer port number TCP Headers Select the TCP IP Header Type Message Length Field required for TCP IP communication from the drop down list None If this option is selected the device will not add or remove any bytes as the length field from the data packets received or transmitted Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Standard If this option is selected the device will add 2 bytes of binary exclusive network order to all transmitted TCP packets and will remove the 2 bytes from the received TCP packets Extended If this option is selected the device will add 4 bytes of binary exclusiv
297. s useful when using an IPSEC VPN tunnel Enter Primary Test IP Address Specify the IP address of a host with which the IP Fallback service will communicate to test connectivity Value must be a pingable address and not a domain name The best choice would be an address that represents end to end connectivity Enter Request Interval in seconds Specify the time in seconds to wait between connectivity tests The minimum is 10 maximum is 600 This value should be 30 or higher for PPP connections Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Test Packets to Send Specify the number of O byte ping packets to send out to test connectivity The minimum is 2 maximum is 30 Recommended value is 5 10 Allowable Test Packet Loss Specify the number of lost packets that are acceptable before the IP Fallback service will consider the link unavailable and switch to its secondary The value must be less than the number of test packets set via Test Packets to Send Select a debugging level Specify a debug level for logging purposes This is recommended only when existing configurations do not function as expected and when directed to change by Technical Support personnel e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10
298. s you the option of adding a certificate deleting a certificate or editing a current certificate Click on the Certificate Manager menu item and the following window will appear Status Networking Services Advanced Certificate Manager Certificate Name Certificate Type Certificate File Add Delete Cancel Apply Sixnet Wireless Toll Free 800 489 7781 Secanaris than Slestearie 7 Fax 314 426 0007 1645 LaGuardia Drive Web wwwJbmelectronics com St Louis MO 631M Www sbaret com Model Number Copyright 2010 Sixnet LLC To add a certificate e Click on the Add button and the following pop up window will appear Enter Certificate Name fo Seach PSEC Select Certificate File e Enter a descriptive name to be associated with the Certificate File to be uploaded This name will be used later in fields where selection of a certificate is required The descriptive name can contain only upper and or lower case letters and digits NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Select the type of certificate that you will be uploading Each certificate is stored in a unique repository depending on the service that will be using it The certificate file name can contain only upper and or lower case letters digits _ and must
299. smChannel psState mode temperature STRING Pulls CELLMODEM_TEMPERATURE from var log wireless cardstats simContextApnO STRING j STRING Pulls CELLMODEM_SIM_CONT_APNO from var log wireless cardstats simStatus serviceDomain availServiceType wCdmaL1sState mmccState gmmPsState STRING Pulls CELLMODEM_SIM_STATUS from var log wireless cardstats STRING Pulls CELLMODEM_SERVICE_DOMAIN from var log wireless cardstats STRING Pulls CELLMODEM_AVAIL_SERVICE_TYPE from var log wireless cardstats STRING Pulls CELLMODEM_WCDMA_L1_ STATE from var log wireless cardstats STRING Pulls CELLMODEM_GMM_PS_STATE from var log wireless cardstats wCdmaChannel STRING Pulls CELLMODEM_WCDMA_CHANNEL from var log wireless cardstats STRING Pulls CELLMODEM_WCDMA_BAND from var log wireless cardstats e xq Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 STRING Pulls CELLMODEM_MM_CS_ STATE from var log wireless cardstats wCdmaBand IndustrialPro Series Router User Manual STRING systemMode Pulls CELLMODEM_SYSTEM_MODE from var log wireless cardstats STRING powerOnTime Pulls CELLMODEM_POWERON_TIME from var log wireless cardstats STRING lowSpeedCsq Pulls CELLMODEM_LOWSPEED_CSQ from var log wireless cardstats STRING highSpeedCsq STRING Pulls CELLMODEM_HIGHSPEED_CSQ from var log wireless cardstats STRING Pulls CELLMOD
300. st E NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the OK button to populate the Host Redirect Rule screen Status Networking Services Advanced Firewall Orig Dest Port Interface New Dest Addr New Dest Port Protocol Source White 443 Au Untrusted 127 0 0 1 10000 TCP default 2022 AJ Untrusted 127 0 0 1 22 TCP default 8080 pppo 10 100 100 10 80 TCP default Sixnet Wireless ps Toll Free 800 489 7781 dermaciv iben Bactrocics Fax 314 426 0007 46 5 ree dia Drive Web www jbmetectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings saved e Click on the OK button to acknowledge the content e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says Firewall settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Masquerade
301. t Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 5 8 TELNET Server The TELNET Server menu item allows you to enable or disable TELNET on the Sixnet router e Click on the TELNET Server menu item and the following window will appear Status Networking Services Advanced Telnet Server Enable TELNET Server No Sixnet Wireless Pome Toll Free 800 489 7781 formerty iben Electronics Fax 314 426 0007 4645 LaGuardia Drive Web www itnelectronics com St Louis MO 63134 www sbmet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu at the Enable TELNET Server field e Click on Yes Status Networking Services Advanced Telnet Server Enable TELNET Sener Yes f Sixnet Wireless p Toll Free 800 489 7781 foe meriy jbm Bectrorics Fax 314 426 0007 4645 LaGuardia Drive Welbwww jbmelectronics com St Louis MO 63134 WWW SixrneLcom Model Number Copyright 2010 Sixnet LLC e Click onthe Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says TELNET Server settings applied e Click on the OK button to acknowledge the content N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushe
302. t Source subnets via whitelist Select a whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking Firewall Subnet Whitelist Rules screen Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Outbound Interface Select the interface associated with the Destination Address Subnet Destination Address Subnet Enter the network to which the firewall will allow access from the Outbound Interface Add Filter Rule eee eae Al Lntrusted Source subnets via Whitdist Outbound Interface Destination Address Subnet e Click on the OK button to populate the Filter Rules screen Status Networking Services Advanced Firewall Filter Rules In Interface Source Whitelist OutInterface Destination pppO default All Trusted 10 100 100 25 32 Sixnet Wireless P ai Toli Free 800 489 7781 fasmaetu Haan Glectronias PX w Fax 314 426 0007 4645 LaGuardia Drive a f m i ya F Web www jbmelectronics com St Louis MO 63134 Ph Ss www sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Save button and the following pop up window will appear t The page at http lt IP Address gt 10000 says gS Firewall settings saved PoE EOE e Click on the OK button to acknowledge t
303. t Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced SSL Server Enable SSL ves Activity Log Level Summary z Wait for Connection sec 20 idle Timeout min eo Certticate Advance Setup Yes Bind interface for accepting SSL Connections Jany f Bind Interface for outgoing TCP Connections Any Bi eee Re 4 NDS RC4 SHA ALL ADH aNULL eNULL LOW EXP SSLv2 RC4 RSA HIGH MEDIUM Keep Alive behavior None f Label SSL Listening IP SSL Listening Port TCP Destination IP TCP Destination Por SixNetTest 0 0 0 0 a00 10 100 100 25 sag Cancel Apply Sixnet Wireless Toll Free 800 489 7781 toe marty jbm Blectron Fax 314 426 0007 4645 LaGuardia Drive i y Webowwwjbrmetectronics com St Louis MO 63134 e S www sixnet com Model Number Copyright 2010 Sixnet LLC Click on the Apply button and the following pop up window will appear t The page at http lt IP Address gt 10000 says S SSL Server configuration applied Ema Click on the OK button to acknowledge the content N Sixnet Inc A Red Lion Business a red lion business 331 Ushers Road Ballston Lake NY 12019 A a A g AAR NN Ta 2 CON T 1 518 877 5173 F 1 518 877 8346 Ind
304. t Wireless Fax 314 42 6 0007 4645 LaGuardia Dri A Web ixnet D4 abuUardia UNVe T e0 WWW SKnetcom St Louis MO 63134 Six r f Send Email to Support 50nd Mal model number Copyright 2012 Sixnet Inc e Click on the Refresh button to display the contents of the modbus xml file e Click on the Download button to send the modbus xml file to your PC You can Edit and Save the modbus xml file under Advanced Expert Mode gt Configure Sub systems menu item and then click on Re Start button to restart the Modbus service Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual 3 5 12 1 0 Settings Test I O Test I O is used to verify the functionality of I O states in gateways RTUs and I O modules Status Admin Networking Advanced device_family Administra Dynamic DNS Installed Firmware Ver SN Proxy Settings firmware revision T SixView Manager GPS Settings Device Senal Numbe SSH Server serial number System Logging System Uptime OD OH 13M 595 TELNET Server Ping Alive sical Interface Stal symp agent Ethernet Interface Connection State IP ik Status usb Up 19 wn etho Up 19 ET I O CTRL Cellular Interface Activation Connection IP Address Signal Strength N A Reg Home Disabled N A HS PA 92 Cellular Uptime N A
305. t be in range of 1 247 Local Port Enter the local port number The port must be within the range of 1 65535 and the recommended default port is set to 502 e Click on the Add button to configure the remote station parameters and the following pop up window will appear Add ModBus Remote Station Table Station Name Station Number Remote IP Address Message Timeout ms Message Retries Station Online Address Station Name Enter the name of the remote station The remote station name must be less than or equal to 32 characters All the defined remote station names will be populated in the I O Transfer screen as a selection for assigning I O transfer for selected remote station name Station Number Enter the remote station number The station number must be in range of 1 247 Remote IP Address Enter the remote station IP address in a valid IPv4 unicast address format or may be blank if I O transfers to this remote station only use the serial port Remote IP Port Enter a valid IP port number 1 65535 that the remote station listens on for MODBUS requests Message Timeout ms Enter the Timeout period in milliseconds to wait for an I O transfer to complete The valid range is 10ms 60000ms Message Retries Enter the number of times to retry an I O transfer before giving up If a station status bit is provided it would be marked off line when this occurs The recommended value is 3 St
306. t in updates being sent to your Dynamic DNS service provider Host Name Enter the host name and domain you wish to be assigned by the Dynamic DNS service Server Name Address Enter the host name or IP Address along with port number if needed user to access the Dynamic DNS Server Example members dyndns com 80 NOTE A recommended value is automatically displayed when you select a Service provider If you require a value other than the recommended value your Network Administrator or Dynamic DNS Service Provider should be able to provide the appropriate value which can be entered manually Server Request Path Enter the Request URI required to connect to the Dynamic DNS Service in this field NOTE A recommended value is provided automatically when a Service type is selected If you require a value other than the recommended value your Network Administrator or Dynamic DNS Service Provider should be able to provide the appropriate value which can be entered manually e Click on the Save button and the following pop up window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual The page at http lt IP Address gt 10000 says Dynamic DNS parameters saved e Click on the OK button to acknowledge the content e Click on the Apply button and
307. ted to an Internal Port 80 Protocol TCP When this feature is enabled a new field will appear containing a table into which multiple entries can be entered Each entry will include the External and Internal Port numbers and a traffic type TCP or UDP Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Enable QutOtBand port re direct Enable port re directing ves Enable traffic restrictions No l Port Re directs External Port Internal Port Protocol Add Sixnet Wireless Toll Free 800 489 7781 formerly jom Electronics 5 e Fax 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 WWW sinet com Model Number Copyright 2010 Sixnet LLC NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual e Click on the Add button to add a port re direction and the following pop up window will appear J af Pr aad T X Add Port Re direction x External Port ooo Internal Port Protocol TCP _ Cancel f ok External Port Enter the IP Port number to be used as the External Port for redirection This is the port that incoming connections are destined to
308. telnet negotiation options with common Telnet Clients which may provide a better user experience If you are having problems with odd echoed characters or other interactive problems please enable this option If you are having problems with login not accepting your password or pressing Enter seems to behave as if two Enter keys have been pressed try one of the Drop options e Click on the OK button to populate the Out Of Band Management screen Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Out Of Band Management Interface Speed bits char Parity Stop Bits Port Use CISCO APH Local Bind 1 ttyS1 115200 68 n 1 4001 yes no n Sixnet Wireless Toli Free 800 489 7781 lice meriy iben Blectron gt Fax 314 426 0007 4645 LaGuardia Drive WebowwwJjbmelecti onics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says OOB settings applied e Click on the OK button to acknowledge the content NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877
309. tempt to retry will resend an unconfirmed data link primary frame when the confirmation has not been received within the configured timeout If the confirmation fails to arrive after the configured number of retries the communications link is considered failed and a reset sequence is required before a new primary frame could be sent Define Application Layer Properties Application Layer Enable Application Link Confirmation The DNP V3 00 Slave Driver can be configured to retry unconfirmed application link primary frames The number of retries the driver sends and the retry timeout are configurable This service is disabled unless Application Link Confirmations checkbox is selected The number of Retries is configurable between O Application Link Retries disabled and 255 The Retry Timeout is configurable between O Application Link Retries disabled and 5000ms Use different SEQ numbers for CONFIRM and RESPONSE Check to enable Click Save to store your configuration and move on to the next tab Object Mapping Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL m red lor business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual DNP3 Object Mapping Configuration Status Admin Networking Services Advanced DNP3 Object Mapping Configuration Define DNP Object Ma D IN X Binary Inputs D OUT Y Binary Outputs A IN AX Andog Inputs A QUT AY
310. the form of filename zip Click on the Open button to populate the Package Installation window CONNECT MONITOR CONTROL Sixnet Sixnet Inc A Red Lion Business i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Package Installation Select Package File lt Directory Patch Location gt lt Patch_Name gt zip BB View package installation history Sixnet Wireless P ai Toll Free 800 489 7781 foe marty jben Blactrom Fax 314 426 0007 4645 LaGuardia Drive WebowwwJjbmetectronics com St Louis MO 63134 WWW sixnet com p Model Number Copyright 2010 Sixnet LLC e Click on the Install button to upload and install the patch e The following warning pop up window will appear The page at http lt IP Address gt 10000 says This action will cause the device to install an update package The package contents may result in changes in the configuration of one or more network interfaces and trigger a reboot of the device Depending on the nature of these changes your connection could be lost incomplete or incorrect network settings could render the device incommunicable Are you sure you want to proceed OO ate io cel emma toad Cancel OD e Click on the OK button e The following Operation Succeeded window will appear The page at http lt IP Address gt
311. the IPSEC configuration e Choose whether you want to include the GWLNX log files by clicking on the pull down menu next to Include gwinx log files and choose No or Yes This reveals activity associated with Protocol Conversion e Choose the method of delivery o If you are downloading the zipped stats file to your computer system click on the pull down menu next to Select Delivery Method and choose Download o Click on the Gather button You will get the following pop up window The page at http IP Address 10000 says Operation Succeeded If you selected the DOWNLOAD method you may click the link when the page refreshes Otherwise the file has been sent via FTP a Siteeemeiiadll e Click on the OK button to acknowledge the content e Click on the link that appears under the Download field once the page is refreshed N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Networking Services Advanced Gather Stats include IPSEC Bar output Yes rd include gwinx tog fites Yes Select Delivery Method Click Link to Download 2 Sixnet Wireless prs Tol Free 800 489 7781 doe merty jbm Bectroric Fax 314 426 0007 4645 LaGuardia Drive S a F Webowwwjbmetectronics com St Louis MO 63134 e WWww sinet co
312. the need to build additional host subnet subnet host and host host tunnels Local Gateway IP Address Specify the next hop gateway IP address for the left participant s connection to the public network Note If no value is provided the tunnel will use the right participant as its next hop Local Private Subnet s Specify the private subnet s behind the left participant expressed in CIDR format yy XXX XXX XXX XXX NN as network netmask More than one can be specified by using to separate each entry Remote Public IP Address Specify the IP address of the right participant s public network interface This field is required if Client is selected as Tunnel Type If Server or Dynamic is selected as Tunnel Type and this field is blank then the value of any will be used in configuration file Remote Gateway IP Address Specify the next hop gateway IP address for the right participant s connection to the public network Note If no value is provided the tunnel will use the left participant as its next hop Remote Private Subnet s Specify the private subnet s behind the right participant expressed in CIDR format XX XXX XXX Xxx Nn as network netmask More than one can be specified by using to separate each entry e Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL n red lor business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Serie
313. the next destination will be attempted Valid range is 2 250 seconds Recommended Setting 10 seconds A value less than 10 seconds is not recommended for a wireless environment e Click on the Apply button and the following pop up window will appear The page at http 192 168 11 139 10000 says ln Sy 1 Apply Operation Succeeded i e Click on the OK button to acknowledge the content 3 6 6 7 CLI Status The CLI Status menu item allows you to view the status of the ports defined in Gwlnx configuration file if the Gwlnx application is running e Click on the Advanced gt Gwlnx gt CLI Status menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced Gwinx CLI Status Gwinkx is Running JBM Electronics Gateway 1000 Linux PCT Compliant Logging Set to 16 Application Version 04 000 368 BT 120 Unit Description Config Version Application Uptime 01 55 15 PCI Compliant Logging Set to 16 Sleep Loop Count Set to 50 Prhread Sleep Count Set to 5000 This is the current state of memory in KB total used free shared buffers cached 1836 26916 34920 0 0 12980 mm Always scroll display to end Enable Auto update soe EE Every 15 second
314. the pull down menu next to Select Web Access Method and select the method by which you would like to access the Gateway Administration Utility You do not need to enter the password in order to change the access method Note The HTTP method can result in better performance and faster page load times however it is less secure than the HTTPS method which uses data encryption to provide a secure connection e lf you are not changing the password click on the Apply button for changes to take effect To change the password e Enter the new password in the Enter New Password field Note For a secure password choose one that is at least six characters long which is not a common word and comprised of a mixture of upper and lower case characters and numbers Sixnet Inc A Red Lion Business CONNEC ONITOR COI s red Mlle business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Re enter the new password in the Confirm New Password field e Click on the Apply button for the changes to take effect e Enter the current password in the Enter Current Password field Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red Han busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual 3 3 2 Certificate Manager The Certificate Manager give
315. ther devices The SNMP Agent allows you to query the unit for information via SNMP using what is called a MIB Management Information Base Standard MIB II queries are supported as well as a custom JBMELECTRONICS MIB A great deal of useful information about the unit including cellular signal strength interface status etc can be queried When configuring firewalls to allow SNMP traffic be sure to allow access to port 161 so that the device may return its results This is the industry standard port for SNMP traffic You may obtain the JBMELECTRONICS MIB by contacting Sixnet support A complete listing of the OIDs found in the JBMELECTRONICS MIB can be found in Appendix at the end of this manual The community string is public Do not enter the quotes N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced RAM 6821HSPA Administrai Dynamic DNS Installed Firmware Vers SixView Manager Firmware Version Number _ 7 GPS Settings SSH Server Device Serial Numbe Serial Number System Logging TELNET Server Ethernet Interface Connection State IP als hae ik Status usb 19 SNMP Agent iwn etho 19 Cellular Interface Activation Connection IP Address Signal Strength N A Unavailable Disabled N A No Service 110 Cellular
316. thernet ports available on the device the WAN ethO port and the LAN eth1 port while the SN series products have ethO and USB ports These ports are auto sensing allowing for greater flexibility The configuration of the Ethernet ports are the same therefore this document will only cover the configuration of WAN ethO Please refer to this section when configuring LAN eth1 Ethernet Interface WAN eth0 Status Admin Networking Services Advanced DNS Settings MAEI E eth Fit eth PPP Dial Backup De PPP over Ethernet Static Routes TCP Global Setings Phy i Ethernet Interface Connection State IP Address Link Status eth Up 192 168 0 1 Up eth1 Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppo S ed Enabled T2 101 201 31 EVDO REW A SAS CEs Disabled Fd Sixnet Wireless E Toll Free 800 489 7781 formerly jbm Electronics aTh i Fax 314 426 0007 4645 LaGuardia Drive n w a eae z Web www jbmelectronics com St Louis MO 63134 ti a E Fr gt WWW sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNEC ONITOR COI red Mlle iisiacs 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual e Click on the ethO menu item and the following window will appear Status Admin Networking Services Advanc
317. tion Address Sdect Protocol Source network via Whitelist E Original Destination Address One To One NAT will perform a complete forwarding of all ports on the Original Destination IP to a new IP address entered in New Destination Both fields can be any valid IP Neither need to be already present configured owned on a local interface of this device Required New Destination Address One To One NAT will perform a complete forwarding of all ports on the Original Destination IP to a new IP address entered in New Destination Both fields can be any valid IP Neither need to be already present configured owned on a local interface of this device Required Select Protocol Choose the protocol type for this port s data Options are TCP UDP All Source network via whitelist Select a whitelist name from the list of names available in the drop down list box provided Whitelists may be viewed defined via the Networking Firewall gt Subnet Whitelist Rules screen Add NAT One To One Rule Onginad Destination Address eee nese ee ele eee 10 100 100 25 Sdect Protocol BIAS Source network via Whiteaist E e Click on the OK button to populate the NAT Rules screen NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Status Adm in Networking Firewall
318. ts per second and half duplex e 100Mbps Full If selected the interface will communicate at 100 million bits per second and full duplex meaning the both sides may transmit and receive simultaneously Obtain Network Addresses via DHCP This field determines how an IP address will be assigned to the specified Ethernet interface If No is selected the interface will have a Static IP Address the IP address will be manually specified The IP Address Subnet Mask and Default Gateway fields will be visible so that the administrator may enter the appropriate information If Yes is selected the interface will have a Dynamic IP Address the router will employ its onboard DHCP client to issue a request for an IP address to the network in order to obtain an IP address netmask and remote gateway and optionally use the remote gateway as the default route In this configuration the IP Address Subnet Mask and Default Gateway fields will disappear and be unavailable to the administrator IP Address This field specifies the IP address to be assigned to the Ethernet port when a Static IP address configuration is selected This field will not be visible or accessible when a Dynamic IP address configuration is selected as the DHCP server will provide the Sixnet router with the IP address that it should use The IP address identifies a device on a TCP IP network Every device on a network must have a unique address The range o
319. tus eth0 Up 192 168 0 1 Up eth1 Up 192 168 1 1 Up Cellular Interface Activation Connection IP Address Signal Strength pppo Succeeded Enabled 72 101 201 31 EVDO REV A eGR eCwnchiiag Disabled M 2 Toll Free 800 489 7781 formerly jbm Electronics Fax 314 426 0007 P ai A 4645 LaGuardia Drive S f Web www jbmelectronics com St Louis MO 63134 i X n e www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Wireless e Click on the Configure Sub systems menu item and the following window will appear Status Networking Services Advanced Expert Mode Select a subsystem configuration to edit from the drop down list provided above Subsystem configuration files managed by the Gateway Administation Utility GAU are subject to being overvritten WITHOUT NOTICE at any time when using the GRU to configure a supported subsystem Changes made to GAU generated files via this expert mode facility will not be retained if the GAU is subsequently used to configure the subsystem Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electror 2 Fax 314 426 0007 4645 LaGuardia Drive ta m T WebwwwJbmelectronics com St Louis MO 63134 te ur s www sixnet com Model Number Copyright 2010 Sixnet LLC The following is a list of the sub system files that are available for editing BGP Daemon CHAP Secrets DHCP Server DHCP Leases DHCP Relay IP Sec DHCP Relay DNS Masquerade DNP3 Sxdnpdrv Config Firewall JBMW
320. tworking Services Advanced Gather Configs Include all jbm ftes No include gwinx fites Yes Include all network files Yes Select Delivery Method sri JBM FTP site Enter Project Name Gather Sixnet Wireless loll Free 800 489 7781 foe marty jhen Electre gt Fax 314 426 0007 46451 aGuat dia Drive i Web wwwwJbmelectromics com St Louis MO 63134 ses www sixnet com Model Number Copyright 2010 Sixnet LLC Sixnet Inc A Red Lion Business CONNE ONITOR CONTROL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual o If you are utilizing the Sixnet FTP site enter a project name such as a company name to designate the file on the FTP site o Click on the Gather button o Ifyou want to input your own FTP site click on the pull down menu next to the Designation field and choose User defined FTP site The display will change to reflect the options available for selecting your FTP site Status Networking Gather Configs include all jbm files No Include gwin files Yes include all network files ves Select Delivery Method FTPs Destination Enter FTP Server Address usl Sixnet Wireless for reat Am Elecir ryi 1645 LaGuardia Drive St Louis MO 63134 Model Number Services Advanced Toll Free 800 489 7 781 Fax 314 426 0007 Web www jJbmelectromcs com WWW sic
321. used to hold the starting address of the range being transformed by NAT the IP s seen by a remote host This address may be owned by an interface on this device or an unowned fake range with a corresponding route static or default Original Destination Address End This field is used to hold the ending address range being transformed by NAT the IP s seen by a remote host This address may be owned by an interface on this device or an unowned fake range with a corresponding route static or default New Destination Address Start This field is used to hold the starting range of real LAN IP of the destination device behind this router New Destination Address End This field is used to hold the ending range of real LAN IP of the destination device behind this router Select Protocol Choose the protocol type for this port s data Options are TCP UDP All Required Source network via Whitelist Select a whitelist name from the list of names available in the drop down list box provided NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Whitelists may be viewed defined via the Networking gt Firewall gt Subnet Whitelist Rules screen Service Access Rules Port Allow The Service Access Rules menu item allows you to define what ports either as a single port or a range of
322. ustrialPro Series Router User Manual 3 5 7 System Logging The System Logging menu item allows you to configure the Sixnet router to send the system logs to a different syslog server designated by IP Address or URL e Click on the System Logging menu item and the following window will appear Status Networking Services Advanced System Logging Forward syslog to remote nost No Cancel Apply Sixnet Wireless r Toll Free 800 489 7781 tor marty jben Blectror cs A Fax 314 426 0007 4645 LaGuardia Drive Web wwwjbmelectronics com St Louis MO 63134 WWww sixnet com Model Number Copyright 2010 Sixnet LLC e Click on the pull down menu for Forward syslog to remote host and choose Yes to reveal the system logging configuration fields Status Networking Services Advanced System Logging Forward syslog to remote host vesz Sixnet Wireless P ai for mer bm Electronicos 4645 LaGuardia Drive St Louis MO 63134 Toll Free 800 489 7781 Fax 314 426 0007 Web www jbmelectronics com www sixnet com Model Number Copyrigit 2010 Sixnet LLC IP Address Name of remote host Enter the IP address of the remote syslog server to which you want to forward messages e Click on the Apply button and the following pop up window will appear The page at http lt IP Address gt 10000 says eS Syslog settings applied e Click on the OK button to acknowledge the conten
323. ut o Band Mat Firmware Version Number VRRP Device Serial Number Serial Number Physical Interface Status Ethernet Interface Connection State IP Address Link Status etho Up 192 168 0 1 Lp eth Up 192 163 1 1 Up Cellular Interface Activation Connection IP Address signal Strength ppp Enabled T2 101 201 31 EVDO REV A Wi Sixnet Wireless 3 Toll Free 800 489 7781 formerly jom Electronics a a Fax 314 426 0007 4645 LaGuardia Drive FW Fo Web www jbmelectronics com St Louis MO 63134 St eR Pr te WWW sixnet com Model Number Copyright 2010 Sixnet LLC e NOTE Please refer to the third party device user manual and or technical support to determine what type of connection is required to connect with the Sixnet router from the RS232 serial port Sixnet Inc A Red Lion Business CONNEC ONITOR CON a red ier busines 331 Ushers Road Ballston Lake NY 12019 T 1 518 8775173 F 1 518 877 8346 IndustrialPro Series Router User Manual Click on the Out of Band Mgt menu item and the following window will appear Status Networking Services Advanced Out Of Band Management Interface Speed bitsichar Parity Stop Bits Port Use CISCO APH Local Bind TE Add EZH Cancel 0 Apply Sixnet Wireless Toll Free 800 489 7781 formerly ibm Electror Fax 314 426 0007 4645 LaGuardia Drive Web wwwjbmetectronics com St Louis MO 63134 WWW sixnet com Model Number Copyright 2010 Sixn
324. will appear Configuration file installed a N Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL i red lon business 331 Ushers Road Ballston Lake NY 12019 T 1518 877 5173 F 1518 877 8346 IndustrialPro Series Router User Manual Configuration file deleted e Click on the OK button to acknowledge the content 3 6 6 6 IP Destination The IP Destination menu item allows you to configure the host processor Server IP Port addresses that Gwlnx application uses for TCP IP communication protocol e Click on the Advanced gt Gwlnx gt IP Destination menu item and the following window will appear NU Si X net Sixnet Inc A Red Lion Business CONNECT MONITOR CONTROL a red lfr business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Status Admin Networking Services Advanced IP Destinations Port 1 Connect Timeout 1 Address 2 Port 2 Connect Tim Toll Free 800 489 7781 Sienet Wireless f 5 Fax 214 4276 0007 4645 LaGuardia Drive Web www sienet com St Louis MO 623134 Send Email to Support BT 63821 HSPA Copyright 2012 Sixnet LLC Address 1 Enter the client primary IP address that GWLNX uses to connect to the host server Required Port 1 Enter the client primary port address that GWLNX uses to connect to the Host server port Required Connect Timeout 1 Specify the time in secon
325. x 314 426 0007 4645 LaGuardia Drive Web www jbmelectronics com St Louis MO 63134 www sixnet com Model Number Copyright 2010 Sixnet LLC Enable NAT Traversal NAT Traversal makes it possible to communicate with networks that are located behind routers connected to the Internet Select Yes if all tunnels will use NAT Traversal and select No otherwise Coordinate IPSec with wireless PPP Coordinate IPSec with wireless PPPoE Sixnet Inc A Red Lion Business CONNE I J Whi CC HOL a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 518 877 8346 IndustrialPro Series Router User Manual Coordinate IPSec Dial up PPP You may select specific actions for above options to be performed either upon PPP connect PPP disconnect or both The available actions include e Do Nothing Perform no action e Restart IPSEC is restarted e Stop IPSEC is stopped With these combinations the connection management may be fine tuned so that the tunnel s may be able to restart faster rather than having to rely on Dead Peer detection or other timeout mechanisms alone To add an IPSEC tunnel e Click on the Add button and the following pop up window will appear Add IPSEC Tunnel Enable Tunnel No Tunnel Name Enter some descriptive text in this field as an aid identifying it The value must not contain spaces Required Enable Tunnel Specify whether you want this tunne
326. x to be used for the physical interface Recommended setting is Auto Detect The following options are available e Auto Detect e 10Mbps Half e 100Mbps Hall e 100Mbps Full Use the best negotiated speed and duplex default Force the interface to 10 Mbps and half duplex Force the interface to 100 Mbps and half duplex Force the interface to 100 Mbps and full duplex Sixnet Inc A Red Lion Business CONNECT MONITOR CO a red lion business 331 Ushers Road Ballston Lake NY 12019 T 1 518 877 5173 F 1 51 8 877 8346 IndustrialPro Series Router User Manual Note An incorrect forced setting will result in communication failure for this interface Enable DHCP Server Select Yes to allow the DHCP Server s to be enabled while IP Transparency is in effect DHCP Subnet Type A calculated subnet will be based on the actual IP address received from the wireless network This option is more compatible with a wide variety of routers but will mask out nearby IP addresses This may make other IP s within the host network unreachable Point to Point will use a 32 subnet but is not compatible with some routers Recommended setting is Calculated DHCP Lease Time Choose the time for DHCP Leases when issuing the Transparent IP Recommended setting is 4 Hours Allow TELNET access to this device Select Yes to allow Telnet access to this device Incoming connections on the specified port will be directe

Download Pdf Manuals

image

Related Search

Related Contents

Ultrasonic Flowmeter Model UFP-10  HP Insight Remote Support - Hewlett  TcpStereo. Manual de Usuario  A.-M. Cubat PMB-Manuels – Impression des étiquettes de prêt Page  Limited Warranty  Zal Perax II  Seguridad Superior  CDP 7370 (41901196)  Sony DSC-WX50/B Marketing Specifications  Wayne JCU50 User's Manual  