1. OPERATION The 4 channels of the MD SVOICE4 must be configured by Jumper JP4 located in the top left corner of the board With JP4 in the Siren position the unit will be configured as 2 recordable voice channels and 2 fixed siren sounds With JP4 in the Voice position the unit will be configured as 4 recordable voice channels Voice messages are stored in non volatile memory and may be re recorded as needed Simply configure Jumper JP4 according to your choice of operation and connect according to the installation diagrams and the following instructions MODE 1 SIREN with VOICE Mode Jumper JP4 in the SIREN position In this mode the 4 channels are split into 2 siren and 2 voice The siren channels are S3 Yelp and B4 Temporal Coded Horn The voice channels are V1 and V2 and have 4 recordable minutes each or 8 minutes combined Positive Voltage Activation Terminals Each channel may be activated by applying 12 Volts DC between the NEG terminal and the positive input Both a siren and voice channel may be activated at the same time to achieve mixed siren and voice output V1 Recordable Voice Channel 1 input V2 Recordable Voice Channel 2 input S3 Yelp Siren input B4 Temporal Coded Horn input Pulsing Voltage Activation Terminals S3 and V1 can automatically detect a pulsed versus a steady activation and play the alternate channel For example if channel S3 Yelp is pulsed then channel B4 Ho
2. Recording Voice Messages Messages may be recorded from the on board microphone or from a PC with a sound card and an ELK 129 interface To record from the onboard microphone place Jumper JP1 in the MIC position JP2 in the REPEAT position and JP3 in the RECORD position Activate the desired channel either by using the on board DIP switches requires power to be applied to 12V and NEG terminals or by applying 12V DC to the desired input V1 V2 S3 or B4 The current message if any will start to play While it is playing press and hold the record switch SW1 and speak clearly into the on board microphone Note that the REC EOM LED should light before you begin speaking To minimize any noise gently release SW1 after speaking The new message will immediately be played To stop the playback turn off the channel switch or remove the trigger voltage To re record the message or to record another channel repeat the above procedure SPECIFICATIONS Model 7 MD SVOICE4 Operating Voltage 11 14V DC Adjustable Current Draw 1 4 1 8 Amp depending on volume setting and speaker load Specifications are subject to change without notice LIMITED WARRANTY LIMITED ONE 1 YEAR WARRANTY AND EXCLUSIONS Manufacturer warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Manufacturer is free of defects in materials and workmanship under normal and proper use for one
3. MD T365 ACCQOUCOOCIOO OBS 8 Channel Recordable Voice Annunciator Module MD VOICE8 Copyright 2012 All Rights Reserved 7 www sentryus com MD D4 R201205 V01 High Voltage Relay MD HVR ol ni Y a K 16 5V AC 1 5A Battery Power Charger MD BPC612 24V AC 7A Battery Power Charger MD BPC61224 eo ow Copyright 2012 All Rights Reserved 8 MD D4 www sentryus com R201205 V01
4. 1 year from the purchase date Manufacturer s only obligation is to correct such defects by repair or replacement at its option if within such one 1 year period the product is returned prepaid with proof of purchase date and a description of the problem This warrant excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other implied warranties of any kind including merchantability and fitness or a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warrant including merchantability and fitness of or a particular purpose is limited to one 1 year Manufacturer is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of any equipment loss sales or profits or delay or failure to perform this warranty obligation The remedies provided therein are the exclusive remedies under this warranty whether based on contract tort or otherwise Copyright 2012 All Rights Reserved 6 MD D4 www sentryus com R201205 V01 RELATED PRODUCTS Timer Relay Module MD TR 365 Days Schedule Timer
5. ODE 1 and MODE 2 Volume and Current Adjust Turning the Volume knob clockwise will increase the output volume The louder the volume the higher the current draw The volume and current draw may be adjusted to match the current capability of the power source Connecting a Constant Power Source To Allow Activation By Low Current Devices By connecting the 12V and NEG terminals to a constant power source the current draw of the channel inputs can be reduced to approximately 30mA since all the operating power will then be drawn from the constant power source A constant power source also allows a voice channel to be activated by a momentary voltage and then finish playing until the end Options for Playback of the Voice Channels The switches marked Activate Channels are provided for programming and for user convenience where manual activation of the channel s may be desired A constant power source must be connected to 12V and NEG terminals in order to use these switches The 1SHOT position of Jumper JP2 restricts playback of a voice channel to only once per activation cycle The channel activation must be removed and then re applied before the message will be allowed to play again NOTE 1SHOT does not work with a pulsing activation The REPEAT position of Jumper JP2 permits the voice channel to play repeatedly for as long as the channel input is activated Copyright 2012 All Rights Reserved 5 MD D4 www sentryus com R201205 V01
6. SENTRYLID User Manual 4 Channel Recordable Siren amp Voice Annunciator Module MD SVOICE4 lits ti wu mec OCCE COOC Oct ge fs sn 09 et 8 A er ere Le pyt Cia 4 oat Aa PERLE FEATURES e 4 channels configurable as 2 siren and 2 recordable voice or 4 recordable voice e Siren sounds classic yelp siren temporal coded horn amp pulsing industrial horn e Temporal coded horn meets ANSI standard for audible emergency evacuation signaling e Maximum record time is 8 minutes divided between the number of voice channels e Recordings stored in non volatile memory e Each channel accepts momentary triggers e One shot or continuous repeat voice playback settings e Built in condenser microphone for recording e Adjustable speaker volume and current draw e Powerful 24 watt audio amplifier for speakers e Line level output for paging systems and amplifiers A Please read the Manual before attempting to use this product MD D4 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT OPEN COVERS OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Disposal of Old Electrical amp Electronic Equipment Applicable in the European BR Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall b
7. amage requiring service Unplug this product from the power source and refer service to qualified servicing personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water d If the product has been dropped or the cabinet has been damaged APPLICATION DIAGRAM INCREASE VOLUME VOICE SREN PA OLD 19 OT se AT REC EOM DISABLE PROGRAMMER PI iP RECORD PCSI CA vO OJo ojo o oj mme O REUORD 12V NEG 1 V2 454 VS SPEAKER Speaker Max 4 Ohms ak mi C2 N O COM N O COM N O COM N O COM 12V DC Relay 1 Relay 2 Relay 3 Relay 4 Voice Ch 1 Voice Ch 2 Voice Ch 3 Voice Ch 4 or Siren or Bell Wiring notes A relay or other normally open switch is used to connect a positive 12V power source such as the 12V terminal to a positive voltage activation terminal When the relay or switch is closed the corresponding channel will play its respective sound or voice message Copyright 2012 All Rights Reserved 3 MD D4 www sentryus com R201205 V01 A jumper wire connecting terminal S3 and B4 will cause either channel to output an industrial horn sound when activated A jumper wire connecting a sound channel to a voice channel will repeat the sound alternating with the voice message when either channel is activated until the trigger is disengaged
8. e handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CAUTION 1 Handle this product with care Avoid any shock or bumping of the product Improper handling could damage the product 2 Requires a proper operating environment This product should be mounted within an enclosure 3 Check the power source voltage The power source voltage should be within the specified range Product must meet the specifications 4 Objects and liquid entry Never push objects of any kind into this product as this may touch dangerous voltage points of short out parts that could result in a fire or electric shock Never spill any kind of liquid on the product 5 Servicing Do not attempt to service this product by yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all service to qualified servicing personnel Copyright 2012 All Rights Reserved 2 MD D4 www sentryus com R201205 V01 6 D
9. rn will be played If channel V1 Voice 1 is pulsed then channel V2 Voice 2 will be played Mixing Siren and Voice Messages To combine a siren sound with a voice message apply 12V DC to both a Siren input and a Voice input at the same time EG To obtain a Yelp siren followed by a burglary voice message 12V DC voltage to channel S3 and V1 at the same time The two channels will alternately play until the trigger is removed Exception Voice channels can be set to play only once per activation cycle by placing jumper JP2 to the 1SHOT position The siren sound s continue until the activation input is removed Copyright 2012 All Rights Reserved 4 MD D4 www sentryus com R201205 V01 MODE 2 VOICE Only Mode Jumper JP4 in VOICE position In this mode the 4 channels are all voice recordable and can hold up to 2 minutes of messages each Two or more channels can be combined into longer messages up to the combined maximum of 8 minutes Positive Voltage Activation To activate a channel simply apply 12V DC between the NEG terminal and the positive channel input Multiple channels can be combined activated at the same time to achieve mixed playback of voice sounds V1 Recordable Voice Channel 1 input V2 Recordable Voice Channel 2 input S3 Recordable Voice Channel 3 input B4 Recordable Voice Channel 4 input NOTE Pulsing Voltage Activation is not available in Voice Only Mode Instructions Common to M