1640 Liquid Level Actuator User Manual
Contents
1. 80d 304 4 7K 100K ANN RI R2 e Sc o o B WHITE CLEAR Oo PI PROBE SHIELD O L P4 GND Figure 3 2 1640 Schematic Diagram M Note If the sampler is connected to a 117 VAC power pack it will be actuated when the liquid first touches the stainless steel pin rather than when it touches the stainless steel ring This occurs because the 117 VAC power pack has an earth ground Thus when the liquid touches the stainless steel pin a current will flow from the pin to the earth causing the input to U1D to become LO which actuates the sampler 3 3 1640 Liquid Level Actuator Section 3 Construction 3 3 Routine Inspection The 1640 probe assembly should be periodically inspected for and Care cracks in the rain deflector and for loosening of the stainless steel pin and or ring If any of these conditions occur the respective parts should be replaced The interior of the rain deflector must be kept clean and free from debris and the vent hole must be free of obstructions Under normal conditions simply wiping the probe assembly off will suffice If heavy deposits build up on the probe assembly it may be cleaned with a soapy solution The Liquid Level Actuator is not serviceable in the field If replacement of parts becomes necessary contact Teledyne Isco 3 4 Teledyne Isco One Year Limited Factory Service Warranty Teledyne Isco warrants covered products against failure due to faulty parts
2. or workmanship for a period of one year 365 days from their shipping date or from the date of installation by an authorized Teledyne Isco Service Engineer as may be appropriate During the warranty period repairs replacements and labor shall be provided at no charge Teledyne Isco s liability is strictly limited to repair and or replacement at Teledyne Isco s sole discretion Failure of expendable items e g charts ribbon tubing lamps glassware seals filters fittings and wetted parts of valves or from normal wear accident misuse corrosion or lack of proper maintenance is not covered Teledyne Isco assumes no This warranty does not cover loss damage or defects resulting from transportation between the customer s facility and the repair facility Teledyne Isco specifically disclaims any warranty of merchantability or fitness for a particular purpose This warranty applies only to products sold under the Teledyne Isco trademark and is made in lieu of any other warranty written or expressed No items may be returned for warranty service without a return authorization number issued from Teledyne Isco The warrantor is Teledyne Isco Inc 4700 Superior Lincoln NE 68504 U S A liability for any consequential damages This warranty applies to the USA and countries where Teledyne Isco Inc does not have an authorized dealer Customers in countries outside the USA where Teledyne Isco has an authorize
3. 1640 Liquid Level Actuator Installation and Operation Guide ANG TELEDYNE ISCO A Teledyne Technologies Company Part 60 1643 009 Copyright 1976 All rights reserved Teledyne Isco Inc Revision H May 2008 Foreword This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment Teledyne Isco recommends that you read this manual completely before placing the equipment in service Although Teledyne Isco designs reliability into all equipment there is always the possi bility of a malfunction This manual may help in diagnosing and repairing the malfunc tion If the problem persists call or e mail the Teledyne Isco Technical Service Department for assistance Simple difficulties can often be diagnosed over the phone If it is necessary to return the equipment to the factory for service please follow the shipping instructions provided by the Customer Service Department including the use of the Return Authorization Number specified Be sure to include a note describing the malfunction This will aid in the prompt repair and return of the equipment Teledyne Isco welcomes suggestions that would improve the information presented in this manual or enhance the operation of the equipment itself Teledyne Isco is continually improving its products and reserves the right to change product specifications replacement parts schematics and instruc tions without notice Contact Inf
4. 8501 USA Phone 800 228 4373 402 464 0231 FAX 402 465 3022 E mail IscoInfo teledyne com 1 2 1640 Liquid Level Actuator Section 2 Operating Procedures 2 1 Connection to a Teledyne Isco Wastewater Sampler The second section of the 1640 instruction manual presents detailed operating procedures for the Liquid Level Sampler Actuator This portion details the procedures which must be performed before using the 1640 The 1640 comes with two velcro Dual Lock fasteners one permanently attached to the switch box the other with an adhesive strip for permanent attachment to the sampler control box Figure 2 2 Remove the backing from the adhesive strip and press the assembly to the control box Make sure the sampler is off and connect the SAMPLER con nector of the 1640 to the FLOW METER socket on the sampler Figure 2 2 Dual Lock Fastener Attached to a Sampler 2 1 1640 Liquid Level Actuator Section 2 Operating Procedures 2 2 Mounting The Probe Assembly Thc 1640 probe assembly should be rigidly mounted above the flow stream using weather resistant hardware The probe assembly is connected to the control box by a 22 ft cable and must be mounted within approximately 22 ft of the sampler Figure 2 3 shows the probe assembly mounted on a stake using the probe clamp supplied with the 1640 The probe is mounted over the flow stream with the stainless steel pin pointing down towards the liquid The plastic ra
5. ET the sampler takes samples only while the liquid is touching the probe assembly When the liquid level rises to the probe assembly the 1640 actuates the sampler The sampler will continue taking samples only as long as the liquid touches the stainless steel ring If the liquid level recedes the sampler will be inhibited until the liquid level again rises to the probe assembly If the liquid level recedes while the sampler is taking a sample it will finish taking the sample before shutting off The TOGGLE RESET switch selection is also used to reset the Liquid Level Actuator You must configure the sampler to respond to the actuator Infor mation on programming the sampler for use with the actuator can be found in the discussion ofthe ENABLE PIN or SAMPLER ENABLE configure option in the sampler s manual All Isco sam plers can be used in either the Time or Flow mode when used in conjunction with the 1640 If the Flow mode is used a Y connect cable Isco part 60 3004 019 will be necessary to connect both the 1640 and the flow meter to the FLOW METER port on the sampler To program the sampler and 1640 when the actuator is set to LATCH the following set of instructions is recommended 1 Program the sampler for the time interval or number of flow pulses between samples following the instructions given in the sampler s manual 2 Momentarily set the 1640 CONTROL switch to the TOG GLE RESET position to reset the actuator 3
6. Set the CONTROL switch to the LATCH position When first actuated the sampler will immediately take a sample if the time period from when the sampler and actuator were turned on to when the liquid level reaches the probe assembly is greater than one time period between samples as programmed on the sampler The sampler will then return to its prescribed time base and take samples at the programmed time intervals If after the sampler and 1640 have been turned on the liquid level rises to the probe before one time interval between samples as programmed on the sampler has passed the sampler will wait until the end of the first time interval to take the first sample Thereafter it will take samples as programmed For example The 1640 is set to LATCH and the sampler is turned on at 4 00 The sampler is programmed to take a sample 2 3 1640 Liquid Level Actuator Section 2 Operating Procedures 2 4 2 4 2 ProgrammingTOGGLE Operation every hour on the hour At 6 20 more than one time interval between samples has passed the liquid level rises to the probe and the 1640 actuates the sampler The sampler then takes the first sample at 6 20 the second at 7 00 the third at 8 00 etc and continues taking samples every hour until it completes it s entire program However if the sampler is turned on at 4 00 and the liquid level rises to the probe at 4 20 less than one time interval between samples has passed then the sampler will take t
7. al Construction 0 0 c eee eee eee ee nens 3 1 3 2 Description of the Electronic Circuitry 0 0 cece eee 3 3 3 3 Routine Inspection and Care 0 ccc teeta 3 4 1640 Liquid Level Actuator Table of Contents Fm X X LLL1X 2 Section 1 Introduction The first section of the 1640 instruction manual provides a general introduction to the Liquid Level Sampler Actuator It includes a brief discussion of the organization of the manual an overall description of the 1640 including a listing of the controls and connectors a list of technical specifications and information for contacting the factory 1 1 Manual Organization The purpose of this manual is to assist the user in understanding the operating procedures maintenance and basic construction of the 1640 Liquid Level Sampler Actuator To accomplish this purpose the manual is divided into three sections The first section provides a general introduction to the 1640 The second section details procedures for setting up and operating the 1640 The third section explains required routine inspection and care as well as the actuator s physical construction 1 2 Description The Liquid Level Actuator is a device used in conjunction with an Isco wastewater sampler to begin a sampling routine when the liquid level reaches a predetermined height Thc 1640 consists of a control box assem
8. bly connected to the end of a 22 ft coaxial cable as shown in Figure 1 1 Refer to Table 1 2 for compatible Teledyne Isco samplers Figure 1 1 1640 Liquid Level Sampler Actuator 1 1 1640 Liquid Level Actuator Section 1 Introduction 1 2 1 Control and Connector The control switch and connector of the 1640 are briefly described in Table 1 1 1 2 2 Technical Table 1 2 contains the technical specifications for the 1640 Specifications Table 1 1 Control and Connector of the 1640 Control Settings Function Control Switch Latch Toggle Reset Selects mode of 1640 operation Latch for latch mode and Toggle Reset for tog gle mode or for resetting the actuator Connector Type Function Sampler 6 Conductor Socket Power input from and output signal to Teledyne Isco wastewater sampler Table 1 2 Technical Specifications of the 1640 Dimensions Control Box Height 2 92 in 7 4 cm Width 1 38 in 3 5 cm Length 2 25 5 7cm Weight 1 0 Ib 453 gm Compatible Isco Samplers 3700 Series Portable and Refrigerated Samplers 6700 Series Portable and Refrigerated Samplers GLS Compact Portable Sampler Glacier Transport able Sampler 6100 VOC Portable and Refrigerated Samplers Output to Sampler Open Collector Power Required 12 VDC Supplied by sampler Ambient Temperature Range 32 120 F 0 49 C 1 3 Contacting Teledyne Isco Customer Service Department P O Box 82531 Lincoln NE 6
9. d dealer should contact their Teledyne Isco dealer for warranty service In the event of instrument problems always contact the Teledyne Isco Service Department as problems can often be diagnosed and corrected without requiring an on site visit In the U S A contact Teledyne Isco Service at the numbers listed below International customers should contact their local Teledyne Isco agent or Teledyne Isco International Customer Service Return Authorization A return authorization number must be issued prior to shipping Following authorization Teledyne Isco will pay for surface transportation excluding packing crating both ways for 30 days from the beginning of the warranty period After 30 days expense for warranty shipments will be the responsibility of the customer Shipping Address Teledyne Isco Inc Attention Repair Service 4700 Superior Street Lincoln NE 68504 USA Mailing address Teledyne Isco Inc PO Box 82531 Lincoln NE 68501 USA Phone Repair service 800 775 2965 lab instruments 800 228 4373 samplers amp flow meters Sales amp General Information 800 228 4373 USA amp Canada Fax 402 465 3001 Email iscoservice teledyne com Website www isco com Zn TELEDYNE ISCO February 1 2006 P N 60 1002 040 Rev C A Teledyne Technologies Company
10. de immune to moisture and dust The actuator hold down the probe tip and the probe ring are all made of stainless steel for corrosion resistance and strength The probe assembly is mounted on the end of a 22 ft coaxial cable The center conductor is terminated by the stainless steel pin The stainless steel ring is crimped over the outer conductor The probe is then covered by a plastic rain deflector which protects it from rain and other unwanted moisture This ensures that the sampler will not be actuated accidently The rain deflector has a vent hole which must be unobstructed so that air can escape from the interior of the deflector as the liquid level rises The 1640 s individual parts are identified in Figure 3 1 3 1 1640 Liquid Level Actuator Section 3 Construction Ax Figure 3 1 1640 Liquid Level Actuator Assembly 60 1644 000 3 2 LS SS SS SS E a ID No Description 1 Probe Clamp not shown Switch Boot N 5030L Rain Deflector Probe Sleeve Cable Termination Pin o c01 A2 C Inn Y Connect Cable Sampler Flow Meter 1640 not shown Part 60 3004 019 Dual Lock Fastener 170 Part 60 3703 123 Dual Lock Fastener 400 Part 60 3703 114 1640 Liquid Level Actuator Section 3 Construction 3 2 Description of the Although the electronic circuitry is enclosed in an epoxy potting Electronic C
11. he first sample at 5 00 the second at 6 00 the third at 7 00 etc until it has completed it s entire program To program the sampler and 1640 when the actuator is set to TOGGLE RESET the following set of instructions is recom mended 1 Program the sampler for the time interval or number of flow pulses between samples following the instructions given in the sampler s manual 2 Set the 1640 CONTROL switch to the TOGGLE RESET position When the liquid level rises to the probe assembly the 1640 actuates the sampler The sampler will react just as it does in the LATCH setting However the sampler will continue taking samples only as long as the liquid level touches the stainless steel ring 1640 Liquid Level Actuator Section 3 Construction 3 1 Mechanical Construction This section of the 1640 instruction manual presents a basic description of the mechanical and electronic construction of the 1640 Liquid Level Sampler Actuator in order to provide back ground information which may be necessary for special applica tions The Liquid Level Actuator is not serviceable in the field If replacement of parts becomes necessary contact Teledyne Isco The 1640 is constructed to be extremely weather resistant and watertight The electronic circuitry is placed inside of the control box which is then filled with an epoxy potting compound The CONTROL switch is protected by a water resistant boot Thus the electronic circuitry is ma
12. in deflector is positioned so that it nearly covers the probe The rain deflector prevents rain from wetting the probe and accidentally actuating the sampler It should be kept clean on the inside The vent hole in the side of the rain deflector must be kept unobstructed so air can escape as the liquid level rises inside of the rain deflector The 1640 will actuate the sampler when the liquid touches the stainless steel ring inside of the rain deflector Therefore the probe assembly should be mounted with the stainless steel ring not the probe tip positioned at the height where the sampler is to be actuated However if the sampler is connected to a 117 VAC power pack the 1640 will actuate the sampler when the liquid touches the probe tip Stake furnished by customer Probe Pd Figure 2 3 Mounting the 1640 Probe Assembly 2 2 2 3 Operation 2 3 1 Latch 2 3 2 Toggle Reset 2 4 Sampler Programming 2 4 1 Programming LATCH Operation 1640 Liquid Level Actuator Section 2 Operating Procedures The 1640 Liquid Level Sampler Actuator is switch selectable for either LATCH or TOGGLE RESET operation The following paragraphs describe in detail both methods of operation When the switch is set to LATCH the 1640 will actuate the sampler when the liquid level rises to the stainless steel ring on the probe assembly The sampler remains actuated even if the liquid level recedes With the Liquid Level Actuator is set to TOGGLE RES
13. ircuitry compound and is inaccessible a description of the circuitry is included in order to provide background information which might be needed for special applications Refer to Figure 3 2 the 1640 schematic diagram Placing the CONTROL switch in the TOGGLE RESET position resets the circuit insuring that it is not actuating the sampler This sets the output of UIA to its HI state causing the 2N3704 Q1 transistor to conduct Thus while the probe assembly is out of the liquid the transistor and the 100 ohm resistor act as a current sink When the probe assembly is not in the liquid the input of U1D is set HI However when the liquid rises until it covers both the probe and the stainless steel ring a current will flow from the pin to the ring causing the input to U1D to become LO Consequently the output of UIA becomes LO which shuts off the transistor This actuates the sampler If the CONTROL switch is in the TOGGLE RESET position the transistor will remain off only while liquid is covering the probe assembly If the liquid level recedes the transistor will again conduct which inhibits the sampler from taking samples However if the CONTROL switch is in the LATCH position when the liquid first rises to the probe assembly the output of U1A will latch to the LO state This will shut off the transistor and actuate the sampler until the CONTROL switch is again set to the TOGGLE RESET position A BLACK O F GREEN O 1008 3109
14. ormation Customer Service Phone 800 228 4373 USA Canada Mexico 402 464 0231 Outside North America Fax 402 465 3022 Email IscoCSR teledyne com Technical Service Phone 800 775 2965 Analytical 800 228 4373 Samplers and Flow Meters Email IscoService teledyne com Return equipment to 4700 Superior Street Lincoln NE 68504 1398 Other Correspondence Mail to P O Box 82531 Lincoln NE 68501 2531 Email Iscolnfo teledyne com Web site WWW isco com Revised September 15 2005 1640 Liquid Level Actuator Table of Contents Section 1 Introduction 1 1 Manual Organization ooooorrr eh hh 1 1 1 2 Description einst RSS ae ee cu A a en 1 1 1 2 1 Control and Connector 0 cece n 1 2 1 2 2 Technical Specifications oooooooooorrorrrrrr ee 1 2 1 3 Contacting Teledyne Isco o ooooooooororrrrr e 1 2 Section 2 Operating Procedures 2 1 Connection to a Teledyne Isco Wastewater Sampler o oooooooooo o 2 1 2 2 Mounting The Probe Assembly 0 00 ce cece eee nee eens 2 2 2 3 Operations en ee CER Deed eee ae cil Ameis 2 3 2 3 1 Lateh 2 4 2 5 22H A AO ERG Ire i oie ee aca EE 2 3 2 3 2 Togsle Reset ai dene Be e Ban rn vau del 2 3 2 4 Sampler Programming 0 eee eee ehh e 2 3 2 4 1 Programming LATCH Operation 0 cee cece eee eee eee 2 3 2 4 2 Programming TOGGLE Operation 0 00 cece ee eens 2 4 Section 3 Construction 3 1 Mechanic
Download Pdf Manuals
Related Search
Related Contents
SEGURIDAD RESPECTO A LA TRASPALETA Français Espagnol Anglais Allemand.p65 HardieBacker installation manual Notice d`utilisation Shimano V-Brake (Deore) Copyright © All rights reserved.
Failed to retrieve file