Home
7250-SIMPLEX User Manual
Contents
1. 2 1 time battery compartment has been opened again to open the electronic lock We can assume no liability for malfunctions resulting from improper use application of force or improper treatment or for the loss of property or assets which are due for example to not properly closing the door for the safe If it is not possible to open the safe even though the instructions above have been followed then kindly contact the manufacturer of the safe B7250E_01 doc Rel 1 vom 01 07 2005 4
2. IEA Sesona le Nes L sungen fur mehr Sicherheit User s Manual No 9999 064 0 User s Manual CombiStar 7250 simplex Security note e Inthe interest of security change the factory CODE 1 2 3 4 5 6 immediately after installation e Never use data such as a birthday which others could deduce from personal information about you when choosing your CODE e Once the new CODE has been entered and with the door open lock and unlock the electronic lock several times using the new CODE Opening the electronic lock with the CODE Jz s 4jsfeJ Correct CODE must be entered twicein sequence when There has been an interruption of power supply such as when changing battery or after entering more than four times a wrong code After entering the CODE open the electronic lock within 10 seconds with the keypad otherwise the electronic lock will close automatically as If incorrect CODES are entered four times in sequence then a 10 second penalty time out period will start running See Page 4 gt Optical and acoustic signals lt Electronic lock Electronic lock CLOSED OPEN Closing the electronic lock The electronic lock will engage automatically 10 seconds after it is opened To finally lock the safe it will be necessary to rotate the keypad once again into its home position Electronic lock Electronic lock OPEN CLOSED W Before leaving the safe it is absolutely necessary to rotate the keypad several times to ensure
3. ions timed delay set for 6 minutes Enter CODE 1 or 2 again Open the lock within Enter CODE 1 or 2 within the release period 10 seconds after the entering the second CODE v yp Timed delay perid Release period is 10 seconds time period set for 6 minutes 2 minutes at time delay periods cannot be changed of from 4 to 10 minutes Activate timed delay only with the electronic lock open J 3 J OJ 2 3 i4j sJ 6 CODE 1 example shown here f Sone Desired time period from LIJI for 1 minute to LJe for 99 minutes Deactivate timed delay only with the electronic lock open EE aea jej CODE 1 example shown here Aoo Opening with timed delay Basje CODE 1 or 2 example shown here Wait for 15x J then Q green Delay time has elapsed release period starts Bajse Enter CODE 1 or 2 once again k lf an incorrect CODE is entered during the release period or if C is pressed then the procedure for opening with timed delay will have to be restarted from the beginning B7250E_01 doc Rel 1 vom 01 07 2005 3 L sungen fur mehr Sicherheit User s Manual No 9999 064 0 Optical and acoustic signals Q Valid CODE entered Green 1 time properly If four incorrect CODES are entered in sequence then a 10 second penalty P icone rolled re eon nome NY Incorrect entry will ex
4. tend the penalty i i Pealnene POE EMETEA time out by 10 seconds The penalty time out period cannot be interrupted The change in the CODE or Q T Chanae accepted ctvation deactivation of the S Green and 4 7 2 times g peer supplementary function carried out properly The change in the CODE or oie activation deactivation of the Y Red and J 12 times Invalid change supplementary function was not carried out properly Repeat procedure Q Tireddeanoenda The electronic lock will not respond to Green blinks every 5 i a A any keypad entries during the timed seconds 9 delay period Release period is running Information on release periods at Timed delay period Opening with timed delay has elapsed Penalty time outis The penalty time out period cannot be Q Red blinks every 5 seconds running interrupted Q Bae Penalty time out has The electronic lock can now be opened S Green and then d7 2 times elapsed by entering the correct CODE 2 xX 1 5 x MICRO AAA Alkaline me Replace the type AAA batteries not Y Red and green blink rechargeable batteries in the near fp Low battery warning future alternately 10 times and CODES will be retained when changing 10 times batteries Enter the CODE twice after changing the batteries JI 15 times and then green Y Sia Keyboard has been Y Green and J 1 time then tampered with or The CODE will have to be entered once replaced Q red und
5. that the electronic lock is closed properly B7250E_01 doc Rel 1 vom 01 07 2005 1 L sungen fur mehr Sicherheit User s Manual No 9999 064 0 nging the CODE only with the electronic lock open Jo e aje J Enter the old CODE 1 ejs BAR E Enter the new CODE 1 example given here 6 5 ajej J Repeat new CODE 1 Creating changing CODE 2 only with the electronic lock open JOA Jelsa J CODE 1 When changing enter CODE 1 or 2 ajj je J Enter the new CODE 2 example given here 4 sjeJzje J Repeat new CODE 2 10 gt D ES ES al Deleting CODE 2 only with the electronic lock open Boe aesae es entercove 1 Cancellation during an entry B7250E_01 doc Rel 1 vom 01 07 2005 2 IEA Sesoni le Nes L sungen fur mehr Sicherheit User s Manual No 9999 064 0 Additional functions for the CombiStar 7250 simplex F To open with a timed delay the CODE will have to be entered once again after the timed delay has elapsed If the CODE is not entered again within the prescribed period then opening with timed delay will have to be repeated from the beginning Timed delay 1 3 minutes gt Release period 1 minute Timed delay 4 10 minutes gt Release period 2 minutes Timed delay 11 99 minutes gt Release period 3 minutes sequence of funct