Home

tensio control

image

Contents

1. 30 no 35 in the memory The om display will show the stored we pressure and pulse rate in 75 alternation IL Press the MEMORY button to go to previous stored values no J Erasing Stored Values 97 You may erase one or all records in the m f memory To delete one record m r Step 1 oO Li Press and release MEMORY button 393 to display stored values Press and release IT MEMORY button again to choose the record that you wish to delete Step 2 Press and hold the POWER button until the display shows dEL Step 3 Press and hold the POWER button After three beeps are heard the selected record is deleted To delete all stored values Follow steps 1 and 2 above Step 3 Press the MEMORY button again and the display shows dEL ALL Step 4 Press and hold the POWER button After three beeps are heard all records are deleted 8 GB CARE AND MAINTENANCE Do not drop Do not modify or disas the device semble the body or the wrist cuff Use a cloth moistened Do not twist with water or neutral the wrist cuff detergent to clean the body of the device and thenwipe it dry Keep the device in a sui table place Avoid high temperatures direct sun Avoid thinner benzene and other harsh cleaners light high humidity and dust 4 Remove the batte Do not press the PO t 00 ries if the device WER button if the cuff has not been properly wrapped around the
2. 12 GB
3. wrist SE will not be used Ay for a long time Ww ERROR MESSAGES Message I E or No display Correction The pressure measured was lower than 20 mm Hg Please measure again The pressure measured was higher than 300 mm Hg Please measure again cB Pumping error Please check cuff and try again The pressure can not be measured due to signal noise Please measure again The pumping pressure is higher than 300 mm Hg Please measure again Low battery Please check and if necessary replace the 2 batteries 10 GB SPECIFICATIONS Display System Liquid Crystal Display Measuring Method Oscillometric Power Source 2 alkaline AAA type batteries 1 5 V Measuring Range 20 300 mm Hg 40 200 beats minute Accuracy 3 mm Hg 5 pulse rate Inflation Pressure Automatic with integrated electrical pump Exhaust Solenoid valve Memory 85 sets Display LCD year date time pressure and pulse Low Battery Indicator Yes Auto Power Off After 150 s w o any operation Battery Life Around 250 operations Operating Environment 10 40 C RH lt 85 Storage Environment 20 50 C RH lt 85 Dimensions 76 x 76 x 38 mm W xD x H Weight Around 133g includingbatteries 11 GB Specifications are subject to change for improvement without notice Calibra tion is recommended every two years
4. force is created by the heart as the ventricle forcibly ejects blood into the blood vessels and through the vascular system Another force is created by the arteries as they resist the blood flow Blood pressure is the result of these two forces What are systolic and diastolic pressures Systolic pressure represents the highest pressure at the height of the heart s contraction Diastolic pressure is the lowest pressure when the heart is resting Is my blood pressure normal See the following blood pressure classification chart released by the WHO World Health Organization for evaluation of your blood pressure level What about low blood pressure Generally speaking a lower blood pressure reading is better unless it causes some uncomfortable symptoms such as fainting and or lightheaded ness Fluctuation and variation in blood pressure Fluctuation and variation in blood pressure The following chart shows possible blood pressure fluctuations during a 24 hour period Diastolic mmHg Hypertension 95 cB Boundary 90 Normal Lower 90 140 160 mmHg Systolic mmHg 160 140 120 100 Systolic 80 ntti YA a 60 T T T gt 0 6 11 AM The following factors will influence blood pressure measurement results and cause variations Bathing Breathing Conversation Meals Smoking Exercise Drinking Alcohol Mo ving Thoughts Mental tension Temperature change etc ABO
5. Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor Geratherm tensio control INSTRUCTION MANUAL Model GP 6220 CE 0118 Manufactured by Geratherm Medical AG Fahrenheitstra e 1 98716 Geschwenda Germany Phone 49 0 36205 98 0 Fax 49 0 36205 98 116 E Mail info geratherm com www geratherm com CAUTION 1 Consult your physician to verify your blood pressure range before using this device at home 2 If the cuff causes any discomfort during measurement press the power key to turn off the device immediately 3 Pull off the velcro strap to detach the cuff if the pressure is over 300 mm Hg and the cuff does not deflate automatically Blood pressure measurements obtained with this unit are equivalent to those obtained by a trained person using the cuff stethoscope ausculta tion method This blood pressure monitor complies with the regulations set out in EU Council Guideline 93 42 EEC of 14th June 1993 concerning Medical Products and with the DIN EN 1060 1 standard Non invasive blood pressure monitors part 1 general requirements and DIN EN 1060 3 Non invasive blood pressure monitors part 3 supplementary requirements for electro mechanical blood pressure monitors A quality management system in compliance with EN ISO 13485 ensures that the required quality criteria are met WARRANTY Three years from the date of purchase INFORMATION YOU SHOULD KNOW BEFORE OPERATING THE DEVICE What is blood pressure A
6. UT THE DEVICE Memory Botton LCD display Battery Cover Power Button EXPLANATION OF DISPLAYS Date Memory hey Baz 88 Low Ly Ll m golg Batey D D aT S ndicator Pa c i ene ri r Diastolic Indicator ag i IPD Irregular Pulse Detection PREPARATION FOR USE Pulse Rate Installing Replacing Batteries 1 Press lightly on the arrow and slide the battery cover in the direction of the arrow 2 Insert the batteries into the battery compartment matching correct polarities and Note e Replace both batteries if the low battery indicator appears Remove the batteries if the device will not be used for a long period of time It is recommended that the same type of alkaline batteries be used to avoid incompatibility 5 GB Attaching the Pressure Cuff 1 Free the left wrist of any clothing etc and wrap the cuff directly around it The display should be positioned on the palm side of the wrist 2 Fasten the cuff Make sure it is not too tight The cuff s upper edge should be approxima tely 1 cm 0 39 inch from the palm line 3 If it is not possible to measure on the left wrist attach the cuff on the right wrist as shown in the figure Measuring Posture 1 Sit upright and place your forearm onthe storage case so that the device is at heart level Relax and measure in a natural position 2 Measure and record blood pressure at the same time every
7. day to establish your blood pressure pattern HOW TO OPERATE THE DEVICE Setting the Clock Enter the clock setting mode by pressing and holding the MEMORY button for over three seconds The display will show a flashing year Press the POWER button to adjust the year when it is flashing Then click the MEMORY button again a month will appear and flash to be adjusted and then date hour and minute will follow as you press and release the MEMORY button To Adjust the Clock Press the POWER button to adjust the month date hour and minute when they are flashing 9i m 9i m 9i me 920 Measuring 9 i8 9 8 3 26 a m Blood Pressure l ICT Press and release the n7 g ni ee raf n POWER button to start LI 5 AC 5 g Ll x NN N measuring automatically N 7 g When the measure Initial Pumping Measuring and ment is finished the display buzzer sounds display will show the measured blood pressure and pulse rate Press the POWER button to turn off the device Otherwise the device will automatically turn off after 150 seconds Note If the symbol appears it means the unit has detected irregular pulse during measurement If the symbol appears regularly please consult a qualified physician for professional advice 7 GB 3 Recalling Stored Values 3 1 Press and release the 3 N os f 5 MEMORY key to recall the 130 last reading Example l L

Download Pdf Manuals

image

Related Search

Related Contents

Step2 入門 - 121ware.com  Sharp MXDE16  モーター走行時の車両を歩行者に音でアピール  Supermicro 5015A-EHF-D525 server  Abbaretz - La GRIGONNAIS – NOZAY - LaMano  Barrière immatérielle de sécurité GuardShield PAC Type 4 (Controle  Caparol UK CAPAROL EXTERNAL WALL INSULATION SYSTEMS  Subaru Robin Power Products RGX2900 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file