Home

guideline for the selection, installation, and operation of parry

image

Contents

1. PATTY or Fig 4 Horizontal installation arrangement electrical connections upward Actual switching points are 11 Pa higher than the scale Fig 5 Horizontal installation arrangement electrical connections downward Actual switching points are 11 Pa lower than the scale Note With the safety cover removed contact with terminals 1 2 and 3 poses a lethal C hazard mains power voltage Adjusting of upper lower switching point Dial B For higher switching point higher pressure turn in clockwise direction Allow pressure to increase gradually do not exceed max pressure limit adjust desired switching point with dial B Check the upper or lower switching points by raising and lowering the pressure several times and make any necessary adjustments N Note N Adjust switch within printed on scale only Do not turn the dial B into the area of the black mark Switching contact changes from NC 1 2 to NO 1 2 1 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 52 of 59 PARRY TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Tube connection Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 53 of 59 TELEPHONE SERVICE 44 01332 875665 FAX
2. Rating Air flow Speed Controller Flange ty Width Depth ght Fan Code m3 s Code i y Flange Code size ST10501F 400 ST12501F 1200 810 500 40 soj 0 400 ST15501F 400 ST18501F 400 ST2150IF 2100 610 500 aoj 5 0 360 400 ST2450IF 2400 810 sooj 0 972 sooj 5 400 2 RGFANDDS 3 3681 128 TRG CONTRTRE12 12 2 RG FLANGEGBO7 400 GT10101F 400 GT12101F 1200 1000 sooj 2 sooj soj sooj 1 RGFANDDS 3 368 054 T1 RGCONTRSCSD 5 186 FLANGE 8897 400 GT15101F 400 GT1810IF 1800 1000 500 os 3 200 360 400 GT21101F 200 400 GT24101F 400 1275 RG CONTRSC5 0 400 TTI575IF 1500 1200 3 sooj soj 500 1 RGFANDDE9 3e8 14 CONTRSCSD 5 1 RG FLANGE 8897 400 TT1875IF 1800 1200 750 sug 50 500 368 400 TT2175IF 400 24751 2400 1200 750 sooj soj 600 358 400 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 27 of 59 PARRY TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 SNACK TYPE CANOPY FAN APERTURE FOR INTERNAL FAN AND DUCTING THIS DRAWING SHOWS THE POSITION OF THE CUT OUTS FOR THE MOUNTING OF AN INTERNAL FAN AND DUCTING THIS DRAWING 15 INTENDED FOR USE WITH THE FOLLOWING UNITS THAT ALL HAVE ONE FAN 5171050 IF 511250 IF sST1550 IF 511850 IF 312150 IF FANS ARE MOUNTED AS STANDARD EXTRACTING OUT THE BACK OF THE CANOPY IF YOU WOULD LIKE T
3. INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 44 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Interlock Controller COOKSAFE PGCS003 Gas and Fan Proving System The Cooksafe PGCS003 is a gas pressure and fan proving system for use in commercial kitchens featuring CE Approved Control Panel Pressure Transmitter and Fan Pressure Switch e Constant monitoring for low gas pressure solation of the gas if the ventilation fan fails e Simple installation and commissioning no complex volume or orifice plate calculations required e Removable key switch for security and Emergency Cut Off switch as standard Assists with kitchen approval to BS61 73 2009 e Low power consumption Can be used on Natural and LP Gas LED status indications e Must be used with an ENI6I Approved solenoid or Electro Hydraulic safety shut off valve e Connections to gas supply safety shut off valve Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk 9 INSTRUCTION REF 13176 ISSUE 1 DATE 2 01 08 Page 45 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 SPECIFICATIONS Inputs 230VAC 50Hz 3 Amps max Outputs 230VAC to gas valve 5 Amp rating LED Indicators Power on Green Testing Yellow Gas on Red Test fail Yellow Low gas supply Yellow Emergency Stop Yello
4. Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk 9 INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 20 of 59 Wiring diagram For the following models 256315 41 ZSC400 41 Z8C450 41 ZSC500 41 Wiring Colours U1 brown U2 blue Z1 black Z2 orange TB white Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 21 of 59 Parry Canopy Specification for Duct Mounted Fans Filter Specifi cation li 5 1050 RG FANZSC315 41 RG CONTRSC15 RG FANZSC315 41 RG CONTRSCI 5 RGFANZSCADD H 034 090 1 RGFLANGEBBS7 400 1 RG CONTRSC3 0 STIG50EF 1800 500 0729 4 400 5 400 1 RG FANFSC450 41 RG CONTRSC5 0 RG FANZSC450 41 RG CONTRSC5 0 ST2450EF 2400 810 500 59 400 50 40 1 RG FANZSCS500 41 RG CONTRSC5 0 GT1010EF RG FANZSC315 41 RG CONTRSCI 5 GT1210EF 1200 1000 2 0 50 500 315 1 5 GT1510EF _ 1500 140 6000076 5 500 1 RGFANZSCADO M 0 31 090 1 RGFLANGESB97 400 1 RG CONTRSC3D 3 GT1810EF x 1800 500 3 500 500 450 GT2110EF GT2410EF RG FANZSC500 41 RG CONTRSC5 0 TT1275EF RG FANZSC315 41 RG CONTRSCI 5 TT1575EF _ 1500 2 04 3 500 5 sooj 1 RGFANZSCADDCM1 031 090 1 RGFLANGEB837 400 1 RG CONTRSC3 0 TT1875EF 500 450 TT2175EF TT2475
5. kW flanges size mm mm mm Code 13AMP 256315 41 8895 13AMP 3 2 275031541 8895 2 1500mm tSAMP 3 13 ZSC400 41 09 031 8630 8897 400 2400mm 1 6 4 75 50041 19 077 58650 889 500 Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 18 of 59 PARRY Duct Mounted Fans Parry sell duct mounted fans as part of the Canopy Value Pack Features of the duct mount short cased axial fans e Sickle amp aerofoil bladed fans 315mm to 500mm e Fan single phase 230V 1Ph 50Hz e Diecast aluminium impellers e Insulation class F IP54 e Operating range 40 C to 70 C e Thermal protection TK Galv steel casing with flanges Corrosion resistant paint pebble Grey e Inlet guard e P54 terminal box Maintenance free sealed for life bearings I Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 19 of 59 Number Fan Controller 2 Flange Dimensions Number w holes B PCD ZSC450 41 YES u ZSC500 41 YES 165 503 567 541 Sze OA OC OD E OF G kg _ 316 382 217 9 5 356 135 8 6 65 400 466 400 9 5 438 155 12 6 103 450 515 415 9 5 487 160 12 6 158 500 567 503 9 5 541 165 12 6 166
6. which when fitted correctly will reduce the noise generated by the fan ZSC Fan noise levels with silencer noise reductions Resultant Resultant Resultant Resultant Noise Noise Noise Noise Level Level Level with 1D ST with 1D POD with 2D ST Silencer Silencer Silencer Silencer ZSC315 41 ZSC400 41 ZSC450 41 ZSC500 41 105 is one fan diameter long without a centre pod 10 POD is one fan diameter long with a centre pod 2D ST is two fan diameters long without a centre pod 2D POD is two fan diameters long with a centre pod All noise levels are measured at a distance of 3 metres Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 24 of 59 7 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Internal Direct Drive Centrifugal Fans Parry offer a new range of canopies with internal fans The internal fans used are centrifugal type fans Unless otherwise stated on an order all canopies sold with internally mounted fans will have the fan extracting through the top panel If the canopy contains one fan it will be fixed to the centre of the top panel if it has two or more fans they will be evenly spread along the length of the top panel If another position is required for the mounting of the fan this is possible at an additional charge Please state the exact dimension at time of order Width of Diam
7. ISSUE No 1 DATE 19 07 11 Page 3 of 59 Gas Interlock e Gas interlock system Interlock controller Pressure switch Gas Solenoid valve and pressure transducer Speed controller installation instructions Warranty information Disposal information Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 4 of 59 PARRY Canopy specifications Snack Type Range General Type Range and Titan Type Range Parry canopies are designed for small and medium size commercial kitchens With three different ranges of canopy on offer there are plenty of styles and sizes to choose from All our instructions and recommendations are based on canopies being fitted with a maximum of 12 meters of duct work and two 90 degree bends The canopies are manufactured from high quality stainless steel and contain a bank of baffle filters that are easily removed for cleaning All canopies are available with the added option of either an internal fan an external fan value pack that includes a speed controller duct mount fan and spigots and a range of lighting solutions These options are explained in full in the relevant sections of this document Canopy Dimensions Snack Type Canopy Suitable for small light duty kitchens or mobile trailers Canopy Code Dimensions Ax Bx C Weight 1000 x 810 x 500 1200 x 810 x 500 1500 x 810 x 500 1800 x 81
8. co uk INSTRUCTION REF IN176 va ISSUE No 1 3 rr DATE 2 01 08 x DARRY Page 59 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Parry Catering recognises our obligations to the EU DIRECTIVE covering the waste disposal of electrical and electronic equipment WEEE Parry Catering are committed to this policy in order to help conserve the environment At the end of this unit s life yu MUST dispose of it in an approved manner You MUST not discard the unit or place it in the refuse bin You have several options a Take the unit to an approved WEEE scheme company there will be one in your area b Take the unit to an approved waste disposal site many sites are managed by your local authority Contact the Parry Group Ltd on the Sales number 01332 875544 for further information on disposal There will probably be a charge for this service which will depend on the physical location of the unit and size you will be given a collection price for a curb side collection based on commercial rates prevailing at the time It should be noted that the unit to be collected should be suitably packed and sealed to prevent dangerous gases and fluids from escaping The condition of the unit must also be clean to comply with health and safety regulations Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk
9. enclosure Complies with low voltage directive 72 23 CEE Complies with EMC directives 89 336 and MODS All models fitted with motor protection fuse Spare fuse included with each controller Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 a DATE 2 01 08 DARRY Page 55 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 e Surface mounting as standard see below EFSC 1 5 and 5 be installed flush using a 47mm metal backing box not supplied e Higher current ratings available to special order Max Full Load Dimensions Weight EE TYPE Current amps HxWxD mm Kg Supply IP51 240V AC 47mm metal backing box 15mm for knob 355 35mm for flush mounting T Wiring Diagram Wiring Diagram for 3 wire control Controller Terminals Supply N Fan or motor terminal box 220 240V 50Hz 1Ph Fan Motor E_ Wiring Diagram for 2 wire control s ur E jum Controller Terminals L Fan or motor terminal box Supply N 220 240V 50Hz 1Ph E Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk INSTRUCTION IN176 4 ISSUE No 1 a T7 DATE 2 01 08 x DARRY Page 56 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Warranty Information WARRANTY POLICY e The manufacturers warranty i
10. the canopy installation as it is commissioned External fan Parry offer all of their canopies with the option of an external fan packs These are especially useful for difficult applications long runs and runs with a change in direction The external fan pack consists of a duct mount fan sized to the length of canopy a pair of flanges and a speed controller Canopies with external fans give the installer greater flexibility as to where the ducting can be mounted Usually the installer would cut the hole in the canopy to suit where the ducting needs to be however if stated with precise dimensions holes can be cut into the canopy at the factory at an extra cost Flanges Duct Mount Fan Speed Controller Parry does not supply any ducting and it is the responsibility of the installer to ensure that extraction ducting complies with all current standards External weather louvered panels are not supplied as standard but can be bought separately from Parry Parry can also supply reducers if you want to change the diameter of ducting leading away from the fan Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 14 of 59 Hanging the canopy on a wall The method chosen to hang the canopy to a wall or ceiling will depend greatly on the type and material of the wall or ceiling It is the responsibility of the installer to check the
11. 0 x 500 2100 x 810 x 500 2400 x 810 x 500 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 5 59 General Type Canopy for small to medium duty kitchens Titan Type Canopy Suitable for medium to large duty kitchens Canopy Code Dimensions Ax Bx C Weight Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 6 of 59 How to join canopies together to form a run sometimes a kitchen scheme may necessitate a series of canopies that can be bolted together onsite to create one large canopy This can be done to achieve a special length of canopy or because access to site is limited Parry offer it s customers the opportunity to do this by providing cut outs to the side panels of the canopy and fixing holes to allow one canopy to be bolted to another oimply state when placing your order that you require the canopies to be joined together in a single run General Type Canopy The diagram above shows an example of the side profile of the general type canopy range with cut out and bolt holes This is available in all styles of canopy Please note that if canopies are to be joined together in this fashion it is the responsibility of the installer to ensure that the canopy has adequate ducting to maint
12. 2 875536 GENERAL TYPE CANOPY FAN APERTURE FOR INTERNAL FANS AND DUCTING THIS DRAWING SHOWS THE POSITION OF THE CUT OUT FOR THE MOUNTING OF INTERNAL FANS AND DUCTING THIS DRAWING 15 INTENDED FOR USE WITH THE FOLLOWING UNITS ALL OF WHICH HAVE TWO FANS T2110 IF 212410 IF TOP VIEW OF CANOPY og 040022 450 00 FO T2110 IF E ii sg ai 450 00 FOR GT2110 IF 1 550 00 FOR GT2410 IF FEE 0 00 1 i gt 5 0D gf 200 00 E a m Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DARRY Page 31 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 TITAN TYPE CANOPY FAN APERTURE FOR INTERNAL FAN AND DUCTING THIS ORAWINGS SHOWS THE POSTON OF THE CUT OUTS FOR THE MOUTINEC OF INTERNAL AND DUCTIHEG TT1230 IF THIS DRAWS 15 IHTEHDED FOR USE WITH THE FOLLOWINGS UNITS WHICH ALL HAVE OHE FAH 1 550 IF TOP VIEW OF CANOPY BACK VIEW OF CANOPY LIEB 14 7 NUT 7 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DADDV Page 32 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 TITAN TYPE CANOPY FAN APERTURE FOR INTERNAL FAN
13. 220 240v 50Hz supply 2 The normal equipment operating range is 0 degrees C to 40 degrees C ambient 3 Component temperature range is 20 degrees C to 60 degrees C Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 va ISSUE No 1 3 rr DATE 2 01 08 3 DARBY Page 37 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 The SC3 5 series are housed in plastic boxes with aluminium front panel and are 1P40 rated The front panel acts as a heatsink and is warm under normal operating conditions DIMENSIONS 87mm wide x 148mm high x 48mm deep ELECTROMAGNETIC COMPATIBILITY AND GUARANTEE Controls are fitted with integral filters and conform to the requirements of the EEC Directive 89 336 EEC and are CE marked accordingly Testing of the units was conducted against the standard for Adjustable Speed Electrical Power Drive systems EN 6 1800 3 1997 unrestricted incorporating EN61800 3 1996 and Harmonics EN 61000 3 The CE mark remains valid only when the unit is correctly installed It is the installers responsibility to ensure that guidelines are followed It should be remembered that when two or more EMC compliant components are combined into a larger system the resulting system may not be compliant Emissions from combined components may be additive It is the EMC conformance of the final system which counts in law All products carry a two year guar
14. AND DUCTING THIS DRAWING SHOWS THE THE CUT OUTS FOR THE MOUNTINGS OF INTERNAL FANS AMID THIS DRAWING 15 INTENDED FOR USE WITH THE FOLLOWING UNITS ALL HAVE TWO FAHS TT1875 IF TI2175 IF TI2Z475 IF TOP VIEW OF CANOPY imm 556 00 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 33 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 SC1 FAN SPEED CONTROLLER INSTRUCTIONS For fans 0 1 1 5amps only IG Systemair Tel 0121 322 0850 SC1 5 Z20074D 1 Phirse 7 ISOLATE FROM SUPPLY BEFORE OPE MNG GENERAL The units utilise triac phase cutting techniques and should be used with motors which have been approved by the manufacturers for speed control by this method Control is best achieved with propeller axial or centrifugal fan loads where absorbed power at full load corresponds to at least 90 of the motor s capacity SPECIFICATION The SC1 is housed in a plastic enclosure rated to 1P40 and designed for continuous operation with 0 1 to 1 5 amp loads at 40 C ambient on single phase 220 240v 50 60Hz supply DIMENSIONS 88mm wide x 88mm high x 70mm deep WARNING 1 Mains voltage is present Care must be exercised when adjusting the internal potentiometer M1N It is the respo
15. EF 500 500 Parry Group Limited Town End Road Draycott Derby England 72 WWW parry co uk INSTRUCTION REF IN176 5 gt ISSUE No 1 MEA DATE 2 01 08 5 DARRY Page 22 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Cut out positions for attaching duct and spigots Iop Elevation A Maximum cut out diameter B Minimum distance from edge to hole centre C Minimum distance from edge to hole centre D Maximum cut out diameter E Minimum distance from edge to hole centre F Minimum distance from edge to hole centre G Maximum cut out diameter H Minimum distance from edge to hole centre I Minimum distance from edge to hole centre Back Elevation Side Elevation Top Elevation Canopy Range A B C D E F G H Snack 400 265 250 315 200 185 400 265 250 General 400 265 250 315 200 200 400 265 262 Titan 500 322 331 400 240 240 500 322 320 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 23 of 59 lt Ta TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Silencer Noise Reduction If the noise generated by the fan in an extraction canopy is causing a problem in terms of noise either inside or outside the kitchen a silencer can be purchased
16. INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 1 of 59 GUIDELINE FOR THE SELECTION INSTALLATION AND OPERATION OF PARRY EXTRACTION CANOPIES MODELS SNACK TYPE CANOPY RANGE GENERAL TYPE CANOPY RANGE TITAN TYPE CANOPY RANGE Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 d ISSUE No 1 m DATE 19 07 11 DARRY Page 2 of 59 Contents Parry Canopy Range e Canopy specifications Canopy dimensions How to join canopies together to form a run Standards for installing extraction canopies Positioning canopies Safety instructions for fitting a canopy Canopy installation instructions Internal fan Repositioning internal fan External fan Hanging on a wall Speed controllers Maintenance instructions Filters e Filter specifications External Canopy Value pack e External value pack specification Duct mounted fans specification Wiring diagram Parry canopy specification for duct mount fans Canopy fan cut out details Silencers for Duct mount fans Internal fans Centrifugal fans e Centrifugal fan specification e Canopy drawings showing aperture cut out for fitting internal fans and ducting Speed controllers e Speed controller installation instructions Canopy Lights e Types of available lighting e Canopy light fitting instructions Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208
17. O CHANGE THE FAN POSITION SIMPLY UN BOLT THE FAN AND SWAP THE FAN PLATE WITH THE BLANKING PLATE ON THE TOP OF THE CANOPY TOP VIEW OF CANOPY 00 BACK VIEW OF CANOPY TC FRONT www parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DADDV Page 28 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 SNACK TYPE CANOPY FAN APERTURE FOR INTERNAL FAN AND DUCTING THIS DRAWING SHOWS THE POSITION OF THE CUT OUTS FOR THE MOUNTING OF INTERNAL FANS AND DUCTING THIS DRAWING IS INTENDED FOR USE WITH THE ST2410 IF WHICH HAS TWO FANS TOP VIEW OF CANOPY Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk A INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DARRY Page 29 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 GENERAL TYPE CANOPY FAN APERTURE FOR INTERNAL FAN AND DUCTING THIS DRAWING SHOWS THE POSITION OF THE CUT OUTS FOR THE MOUNTING OF AN INTERNAL FAM AND DUCTING THIS DRAWING IS INTENDED FOR USE WITH THE FOLLOWING UNITS WHICH ALL HAVE ONE FAN GTIOIO IF GTI210 IF CzT1510 IF GT1810 IF TOP VIEW OF CANOPY REAR VIEW OF CANOPY Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk E INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DADDV Page 30 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 0133
18. SERVICE 44 01332 875536 Gas Solenoid Valve and Pressure Transducer The pressure transducer monitors the gas pressure in the pipe work If the pressure is found to be low the system highlights that there could be a gas leak and the electrical power supply is disconnected from the gas solenoid valve causing it to close and cut off the gas supply To reactivate the system a manual reset is required on the Interlock controller This will instigate a further pressure check and if all is found to be satisfactory restore electrical power to the gas solenoid which will open the valve Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 54 of 59 Tout TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 EFSC RANGE FAN SPEED CONTROLLERS General A range of Electronic Fan Speed Controllers EFSC designed for speed controllable single phase motors up to 10 amps peak current The facia is white with black knob switch and printing All models have a double pole illuminated on off rocker switch A facility to set the minimum and maximum fan speed is standard 2 or 3 wire control as standard Electronic stepless speed control Minimum and maximum speed set facility internal EFSC 1 5 complete with standard moulded double pattress box EFSC 3 and 5 complete with double gang mini trucking box EFSC 10 housed in die cast
19. ain the airflows required through the canopy and comply with all current regulations It may be the case that air will need to be ducted out of the canopy at several points along its entire length Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 d ISSUE No 1 m DATE 19 07 11 gt DARRY Page 7 of 59 Standards for installing extraction canopies There are many considerations that must be taken into account when specifying a canopy for a kitchen for example Size of room Appliances positioned underneath and around the kitchen Location of doors and windows of fan Air flow Rating Length and positioning of ducting Noise Smell Health and safety To help decide which size and type of canopy you require for your installation there are a number of standards and recommendation documents available The Heating and Ventilating Contractors Association have provided a series of specification documents for canopy installation including HVCA Specification for Kitchen Ventilation Systems DW 172 The British Standards that regulate gas catering appliances also specify the type of canopy that should be used with that appliance and should be consulted Health and safety regulations will also have reference to ensuring that an area that contains catering equipment has sufficient ventilation and air circulation Parry Group Limited Town E
20. aining of grease into the drip tray The weight of the ducting and fan should not be placed on the canopy The fan and ducting must have their own fixing Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk P INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 DADDV Page 11 of 59 e Should vibration occur adjusting the fixing will help The canopy must have a minimum of 3 fixing per section e Since all sites vary the ventilation outlet should be cut on site Internal fan For canopies that have internal fans please ensure the fan is in the correct position before attempting to mount the canopy to a wall The centrifugal fan used within the internal fan packs draws air from both sides so to work most effectively it has to be located centrally to give an even draw across the length of the canopy In the longer lengths two fans maybe required and these are spread equally a third of the way along the canopy length Canopies with two fans require two sets of ducting or a non return valve Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 DADDV Page 12 of 59 Repositioning the Internal Fan As standard canopies with internal fans will have the fan mounted to duct out of the centre back of the canopy as shown in figure 1 However if required the fan can be moved to duct out of the centre t
21. antee when correctly connected to suitable specified fan motors Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DARRY Page 38 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 PCB LAYOUT CONTROL WIRING THE MOTOR Motor wiring is shown below 2 WIRE SPEED CONTROL MOTOR CAP CONTROL LIVE OUT NEUTRAL OUT N1 6 4 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 va ISSUE No 1 A DATE 2 01 08 x DARRY Page 39 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 WARNING Mains voltage is present Care must be exercised when setting potentiometers It is the responsibility of the user to ensure compliance with the Health and Safety at Work Act 1974 MOTOR PROTECTION Fuses in the units are for protection of the controller wiring and components in case of short circuits They do not afford motor overload protection The installer should provide motor protection as recommended by IEE Regulations CONTROLS 1 On Off Switch This isolates the motor from the live line Live remains present on the fuse and neutral remains present on the PCB unless a separate isolator is fitted before the controller 2 Front Panel Rotary Knob This enables the user to vary the fan motor speed from a pre set minimum to maxi
22. ctive device specific requirements on the type of protection must be fulfilled Do not change adjustment of factory adjusted and paint sealed switches screw B and C Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk 9 INSTRUCTION REF IN176 ISSUE No 1 Ji DATE 2 01 08 E DARRY Page 49 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Screw C was adjusted in the factory and the adjustment fixed with adhesive This adjustment may not be changed Change the switching point with B screw only Adjust upper and lower switching points with the dial B In case of vacuum connect P2 Adjustments as indicated in the instructions except pressure vacuum Fasten bracket to switch with original factory supplied screws only Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 50 of 59 PARRY TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 1 Supply cable 2 NC contact 3 NO contact all fixing brackets Fig 3 Recommended installation arrangement vertical factory calibration Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 51 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536
23. e customers warranty been put on hold until the bill has been settled Any issues regarding the raised charges should be put in writing to our warranty department for further investigation Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk o INSTRUCTION REF IN176 E ISSUE No 1 DATE 2 01 08 DARRY Page 58 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Disposal Information This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product A symbol on the product or on the documents accompanying the product indicates that this appliance may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental regulations for waste disposal For more detailed information about treatment recovery and recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry
24. eter Motor FANDD9 9 9 C 9 368 1400 Minimum External Air flow Air flow resistance connection m3 h m3 s Pa Weight Kg V ph Hz FANDD7 7 0 14 1150 039 75 69 230 501 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 25 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Internal Fans Sizes DD 7 7 DD 9 9 T DD double inlet Fan Selection Curves DD FORWARD CURVED Double inlet APst Pa 400 K EENEN DD 7 7 14 SSS Ens DD 9 9 9 SS SER 7 00 9 9 14 o ee LANI LL NC ro S ES att LY eee Hd NE NOI IN EN UM CUM 300 N B N a 1 ss TEM REBEEETEKEREEENE M 0 1000 2000 3000 4000 5000 6000 1000 m h 0 25 0 5 0 15 1 1 25 1 5 1 75 m s Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk INSTRUCTION REF IN176 a ISSUE No 1 w DATE 2 01 08 D nma Page 26 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Parry Canopy Specification for Internal Centrifugal Fans Filter Specification Internal Fan Specification Speed Controller Flange
25. indicator will flash for 10 sec and if ventilation is not resumed in this time the gas supply will be isolated In this event the key switch should be turned to the OFF position and a check should be made that all gas taps are closed and that the ventilation system is running Once this is rectified testing can be restarted by turning the key switch to the ON position Installation must be by a qualified electrician and must meet all local regulations The mains supply should be externally fused at 3 amps Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DADDV Page 48 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Pressure Switch Operating and Fitting Instructions Differential pressure vacuum and overpressure switch Caution Before you take the pressure switch into operation make sure to read these operating instructions thoroughly In the event of damages due to the non observance of these instructions improper operation or use of the switch for purposes for which it is not intended the warranty becomes null and void We shall not be held liable for resultant consequential damages The switch is to be installed and removed by technicians only The applicable certified national safety regulations for the operation of pressure measuring devices shall be observed In the installed condition the respe
26. ire an inset or surface mount light box Bulk Head Light e High quality die cast bulkhead e Suitable for vandal resistant or industrial applications Glass or polycarbonate diffuser 20mm cable entry knock out Die cast aluminium body BC lampholder for GLS versions or G23 for PL S versions e IP 65 i AN WIN Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 42 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Canopy Light Fitting Instructions Inset Light Box If units were to be fitted into a ceiling or cupboard etc then the following size holes would need to be cut to allow the unit to recess SLB700 685 x 130 5181000 985 x 130 SLB1300 1295 x 130 DLB700 685 x 255 DLB1000 985 x 255 DLB1300 1295 x 255 Surface Mount Light Box There are fixing holes on the light box body that can be easily marked through and drilled to fasten to the underside of the top of the canopy Bulk Head Light Box Fixing holes can be drilled through the aluminium body allowing the light to be attached in the required position on the underside of the top of the canopy To fix place the body on a firm surface and remove rear knockouts from inside the body using a suitable punch striking sharply on the knockout near the periphery but away from the securing tags Note to maintain IP rating and
27. machine can not be resolved please contact the company that Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 W ISSUE No 1 Me DATE 2 01 08 4 DARRY Page 57 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 supplied you the machine SERVICE CALLS CAN NOT BE PLACED DIRECT WITH PARRY NOT COVERED UNDER WARRANTY e Fault due to poor maintenance Resetting of equipment or circuit breakers Abuse of the equipment Foil should never be used on racks Blockages eg drains condensers pumps etc Lime scale related issues e Installed incorrect Access arranged for service call and engineer refused access or customer not there No faults with the machine e Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burner cooker Excessive carbon build up on griddle plates Over use of lava rock on the chargrills recommended use by Parry 2kg only e Faulty electrics eg customers plug socket plug wiring junction box fault wrong fuse e Any damages caused by the customer e Lamps glass door gaskets Perspex baskets knobs all perishable items are not covered All of the above are not covered under our warranty policy Any costs incurred because of the above will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in th
28. mum speed 3 Minimum Speed This internal board mounted control pot provides minimum speed adjustment to as low as 10 of the maximum rated motor speed 4 Maximum Speed This internal board mounted control provides maximum speed adjustment This control is provided to reduce any dead band the motor may have WIRING THE CONTROL Make the connections to the control as follows Terminal No 1 Supply Earth 2 Supply Live L 3 Supply Neutral N 4 Motor Neutral NI 5 Do not use 6 Motor Control Live L1 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk Ea ers an INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 App Page 40 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 INSTALLATION INSTRUCTIONS 1 Install the control in a well ventilated area where the ambient temperature does not exceed 40 C Ensure the control is securely mounted Route cables through knock outs at the bottom of the unit and ensure electrical connections are correct owitch on the mains supply Switch on the speed controller Hardstart The control applies full power to the load for a few seconds before dropping back to minimum Rotate speed control knob fully clockwise and check that the fan accelerates to full speed Minimum Speed The minimum speed is preset and does not normally need adjusting If thi
29. nd Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 8 of 59 PARRY Positioning canopies The size of the canopy installed in a kitchen will be specified by the equipment which is being situated below it The standard DW 172 states that Unless restricted by walls the plan dimensions of the canopy will always exceed the plan dimensions of the catering equipment by a minimum of 250mm on each free side and by 250mm front and rear The diagram below shows this INFILL CANOPY 250 MIN 50 SPLASHBACK APPLIANCE APPLIANCE MMC s aes Typical Canopy Dimension diagram taken from DW 172 Specification for Kitchen Ventilation Canopy code Maximum depth of unit that can be positions underneath it Snack Type General Type Titan Type Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 rat DATE 19 07 11 4 DARRY Page 9 of 59 Safety instructions for fitting a canopy IMPORTANT PLEASE READ INSTRUCTIONS FULLY BEFORE USE Parry canopies have been designed to be fitted in a kitchen over an appliance as part of an extraction solution Please note that it is the responsibility of the architect customer to specify the correct size and capacity extraction unit for their particular situation and this must be done and fitted in accordance with the regulations in force with
30. nsibility of the user to ensure compliance with the Health amp Safety at Work Act 1974 2 Ensure that the motor is suitable for speed control with a triac device Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk 9 INSTRUCTION REF 176 E ISSUE No 1 2 01 08 DARRY Page 34 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 3 Ensure the motor run current does not exceed the rating of the controller 4 Isolate mains supply before connecting 5 This unit must be earthed 6 All wiring must be in accordance with current IEE regulations 7 Circuit Board Protection Fuses in the units are for protection of the controllers wiring and components in case of short circuits They do not afford motor overload protection Fuse size 3 15 amps ALL ELECTRICAL CONNECTIONS SHOULD BE CARRIED OUT BY A QUALIFIED ELECTRICIAN ELECTROMAGNETIC COMPATIBILITY AND GUARANTEE Controls are fitted with integral filters and conform to the requirements of the EEC Directive 89 336 EEC and are CE marked accordingly Testing of unit was conducted against the standard for Adjustable Speed Electrical Power Drive oystems EN 61800 3 1997 unrestricted incorporating EN 61800 3 1996 and Harmonics FN 61000 3 The CE mark remains valid only when the unit is correctly installed It is the installers responsibility to ensure that guidelines are followed It should be remembered tha
31. op of the canopy as shown in figure 2 Figure 1 Figure 2 Please note that by removing the baffle filters and filter spacers by lifting and dropping them out of the channels you should be able to have just enough room to unbolt the fan and reposition it The fan is bolted to a plate with a square hole in it using four pieces of threaded bar The plate is then bolted to the canopy through the same holes as the flange To block off the holes in the canopy that are not being used there is another plate this time solid It contains the same fixing holes as the fan plate so can simply be bolted to the canopy in exactly the same way making the two plates interchangeable If you do need to move the position of your fan please note that it will only fit in one way round When located on the back the flat side of the fan is facing downwards and when mounted on the top the flat side is facing forward as illustrated above Please ensure that all the bolts are securely tightened before hanging the canopy on the wall An earth tag has been provided and we would recommend that all units are earthed Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 13 of 59 PARRY Information about the rating of the fan can be found on a label on the left inner side of the canopy We would recommend you use this label to record the information relating to
32. particular attention paid to the Health and Safety at Work Act e All appliances other than those fitted with a sealed moulded plug must be fitted by a qualified electrician in accordance with current regulations e To prevent shocks all appliances whether gas or electric must be earthed e To avoid scratching the highly polished exterior surface of this equipment whilst in transit the protective film on the exterior surfaces has NOT been removed e tis IMPORTANT that this protective film is peeled off before the equipment is used e Ensure the unit is isolated from the power supply before installing cleaning or maintaining any part of the extraction canopy e All gas appliances should be installed by a registered fitter in accordance with current regulations e Canopies in the range due to their size or the fact they may contain internal fans can be heavy Take care when moving them We would advise fitting the canopy to the wall or overhead beam requires a minimum of two people Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk 1 DARBY Page 10 of 59 INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Canopy Installation Instructions All gas appliances and gas interlock systems must be installed and commissioned by a registered gas safe fitter Electrical products and the wiring of lights and speed controllers must be fitted by an electrician All ventilation ducting must be ins
33. rent regulations Parry fit baffle filters as standard in all of the canopy ranges There are two sizes of filters 400mm square and 500mm square The pressure drop across the filters on any canopy using the 400mm or 500mm baffle filters is a total of 50 pascals across the unit The Snack type canopy range use the 400mm filter and the General and Titan type use the 500mm Parry also supply as a spare 430 x 430 mm mesh filters to anyone who has an old mesh filter canopy Filters must be washed regularly and drip trays mounted under the unit should be emptied and the Canopy wiped down Parry can offer a filter sterilization unit to make the process of cleaning filters much easier The unit consists of a tank which cleaning fluid can be poured into and filters submerged in For more information contact the Parry Group Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 17 of 59 PARRY External Fan Value Pack Specification Canopy VALUE PACK 3 1 5 CAME osu Value Canopy Packs include a canopy voltage controller a fan and connecting Spigot The fans have been specified to be used with a maximum of 12m of ducting with two 90 degree bends The fans are rated to an IP rating of IP54 Dust and splashes Canopy Single Filters Filters Fan Spec Flow Rating Controller Pair Ducting Length Phase 400 500 m3 sec
34. rews Do not over tighten these screws Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk m ua pen Beer iu F b M 1 1 7 INSTRUCTION REF IN176 ISSUE No 1 Nn DATE 2 01 08 Page 47 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Settings Fill time Set using Switch 1 to 10 or 20 sec factory default 10 sec Prove time Set using Switch 2 to 60 or 120 sec factory default 60 sec If the remote Emergency Stop is not required a wire link should be inserted to connect the two Emergency Stop terminals on the PCB Operation Safety owitch on the power and check that the green Power indicator is illuminated owitch on the ventilation fan and check that the yellow Fan Operating indicator is lit Insert the key into the key switch and turn to the ON position The yellow Testing indicator will be lit continuously for the Fill time as set above and then flash at 1 sec intervals for the duration of the Prove time If at the end of this time the pressure in the outlet pipe work is sufficient then the red Gas on indicator will be lit and the gas will be supplied normally If at any time during the Proving cycle the pressure in the outlet pipework should drop to less than 80 of the inlet gas pressure the yellow Test fail indicator will be lit If the ventilation fails the Fan Operating
35. s All fans in canopies are required to be fitted with a speed controller The table below shows the fans we supply and the appropriate matching speed controller Speed controller RGFANZSOSISdi 4 RGCONTRSCTS RGFANZSCQO4i 1 RG CONTASOS RG CONTRSCS 0 RG FANZSCS500 41 1 CONTRSCSO RG FANDD7 7 RG CONTRSC3 0 RG FANDD9 9 RG CONTRSC5 0 RG FANDD9 9 RG 2 Maintenance Instructions The kitchen manager should ensure that the internal sections of the canopy are inspected regularly and cleaned to prevent a build up of grease which could start a fire Filters MUST be washed regularly For more information on how this can be done easily with a filter sterilization unit see the filter section Filters are easily removable for cleaning by simply holding on to the handles and Sliding the filter up into the unit allowing the bottom of the filter to drop forwards out of the unit Care should be taken when removing filters as generally the unit will be mounted high up on a wall over catering appliances All Parry canopies are fitted with a drip tray The drip tray is easily removable and must be emptied regularly The unit should be wiped down regularly with warm soapy water and a soft cloth Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 16 of 59 PARRY Filter Specification In accordance with cur
36. s is necessary firstly ensure the control knob is set to minimum fully anti clockwise then remove the front panel to access the potentiometer MIN Adjust as required Beware of setting too low a value which would cause a stall condition on the fans Maximum Speed The maximum speed is preset to full speed If it is necessary to adjust then first ensure the control knob is set to maximum and remove the front panel to access the potentiometer Adjust as required Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 41 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Canopy Lights Types of available lighting Lighting solutions can be sold to fit in the Parry ranges of canopies Inset or Surface Mount Light Boxes a e Stainless steel construction ee Obscured toughened glass One 13amp plug Hemovable cover to change light bulb External Dimensions SLB700 720mm length x 165mm wide x 75mm deep SLB1000 1020mm length x 165mm wide x 75mm deep SLB1300 1320mm length x 165mm wide x 75mm deep DLB700 720mm length x 290mm wide x 75mm deep DLB1000 1020mm length x 290mm wide x 75mm deep DLB1300 1320mm length x 290mm wide x 75mm deep Power Rating SLB7002 1 x 18W SLB1000 z 1 x 30W SLB1300 1 x 36W DLB700 2 2 x 18W DLB1000 2 x 30W DLB1300 2 x 36W Please specify at time of order whether you requ
37. s only valid in the UK mainland amp Northern Ireland Western Isles Inner Hebrides and Islands are parts only warranty All service calls will be carried out between the hours of 8 00am 5 00pm Monday to Friday only We accept no responsibility for delays in replacing or repairing the equipment due to circumstances beyond our control e Your warranty can be immediately invalid if the installation of the equipment has not been installed in accordance with the manufactures instruction See installation details Also the miss use alteration or unauthorised repairs of the equipment will invalidate the warranty During the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufactures instructions and maintenance guide lines he warranty covers defects in the material and components failure only We are not liable for trading loss loss of perishable items water damage loss due to injury or fire damage WARRANTY REQUEST Please ensure you have referred to the manufacturers instruction before placing a warranty call Or contact our warranty department on 01332 875665 for technical assistance Please ensure you obtain the model number before calling Please ensure you have read the section not covered under warranty to avoid any unnecessary warranty charges f the problem with the
38. structure is strong enough for the weight of the canopy and to use appropriate fixings If a canopy has been supplied on a stand or mounted to a table it may still need to be tied to a wall or ceiling for rigidity 1 Choose a Suitable position for your unit taking into consideration ducting the location of units underneath it and current standards Do not butt the unit up against another unit which will get hot Do not let the position of the unit blank off any ventilation vents on any other adjacent units Remove all protective film and packing material Holes can be drilled through the back or top of the canopy to screw directly to a wall or ceiling In some circumstances it may be beneficial to run a baton along the wall for the unit to sit onto as well as screwing directly into the wall If in the case of a condensate canopy the unit may be suspended from the ceiling with chain Take steps to prevent the canopy from swaying which could happen as doors into the room are opened and closed Please note that on each canopy a fat collection tray may be situated to one side of the unit and on condensate canopies a drain valve is located in one corner To help the liquid flow into the drain or tray it is best to fix the unit at a slight angle Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN208 ISSUE No 1 DATE 19 07 11 Page 15 of 59 Speed Controller
39. t when two or more EMC compliant components are combined into a larger system the resulting system may not be compliant Emissions from combined components may be additive It is the EMC conformance of the final system which counts in law All products carry a two year guarantee when correctly connected to suitably specified fan motors Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 35 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 WIRING THE CONTROL 2WIRE SPEED CONTROL Earth 240vlivein 240 v Neutral in Z Motor Neutral out CONTROL LWE OUT NEUTRAL OUT Li Ni Do not use 4 Motor Control Live out Terminal Connection let 220 240 volt 50 60 Hz Live in supply 220 240 volt 50 60 Hz Neutral in supply 1 Neutral Out LZ D0 use L1 Motor Control Live Out SET UP AND RUNNING INSTRUCTIONS 1 Installthe controlin a well ventilated area where the ambient temperature does not exceed 40 C 2 Ensure the control is securely mounted 3 Route cables through the knock out holes at the bottom of the unit and ensure electrical connections are correct 4 Switch on the mains supply Switch on the speed controller 5 Rota
40. talled to comply with currents standards and building regulations Parry offer a range of sizes of canopies If a customer requires a canopy that is longer than 2400mm several canopies can be joined together Baffle filters and fixing bolts to attach the canopies together are supplied with the unit Any fixings for hanging the canopy on to the wall must be sourced by the customer installer and the fixings used should be suitable for the wall type that the canopy is being fixed to Canopy Lights are sold separately Hemember that a canopy is flexible and must be handled carefully Each construction site is different and fixings must be designed to suit each installation The preferred and safest way to assemble and raise a large canopy is to prepare a large temporary wooden raft placed on a flat floor on this raft the canopy may be assembled this way minimises distortion when assembling The canopy can be lifted up on the raft and exactly positioned by lifting from below or by pulley blocks from above The canopy can then be fixed to the building structure in such a way that the canopy weight is uniformly distributed To avoid distortion of the canopy or tearing under its own weight it may be necessary to use spreader plates on the canopy When all fixings are in place level up the canopy and tighten all fixings note that a drip tray is located to one side under the canopy by fixing the canopy at a slight angle will improve the dr
41. te the control knob from an anti clockwise position to a clockwise position and check the fan accelerates to fill speed 6 Minimum Speed The minimum speed is preset and does not normally need adjusting If this is necessary firstly ensure the control knob is set to minimum filly anti clockwise then open the lid to access the potentiometer MIN Adjust as required Beware of setting too low a value which could cause a stall condition on the fan Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk 9 P INSTRUCTION REF IN176 ISSUE 1 DATE 2 01 08 Page 36 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 SC3 amp 5 FAN SPEED CONTROLLER INSTRUCTIONS For fans SC3 up to 3amps and SC5 up to 5amps only let irf sn DIJI UE GENERAL The units utilise triac phase cutting techniques and should be used with motors which have been approved by the manufacturers for speed control by this method Control is best achieved with propeller axial or centrifugal fan loads where absorbed power at full load corresponds to at least 9096 of the motor s capacity SPECIFICATION Maximum Continuous Model Number Running Current Size Amps Amps 1 The SC3 and SC5 controls are designed for continuous operation as shown in the above table indicating maximum continuous load current at 40 degrees C ambient on single phase
42. w Fan Status Yellow Dimensions 128mm Width x 179mm Height x 59mm Depth Contents 1 x Provengas Cooksafe control panel 1 x pressure transmitter 1 x air pressure switch See page 39 for full details 1 x duct APS connector kit 2 X copper pipe 8 mm x approx 10 cm long 1 x brass tail R 1 4 tail to 8 mm tube 1 x 90 fitting R 1 4 male elbow x 8 mm nut olive 1 x straight fitting R 1 4 male x 8 mm nut olive 2 x large cable glands M16 1 x small cable glands PG7 Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 Page 46 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Connections Model COOKSAFE REMOTE EMERGENCY STOP EXTERNAL FUSE 3A LINK OUT IF NOT USED 3 at e MAINS 230 TO VALVE PRESSURE SWITCH ETEA 2 3mbar QD Mounting Fit the Control valve and using the fittings provided pipe in the Gas Pressure transmitter to the Control Valve output use the Control valve Test point tapping if available There are no pre drilled holes in the Cooksafe enclosure for the input output cable glands as these must be drilled in the appropriate position for the installation Prior to drilling the PCB must be removed Once the holes have been drilled they must be carefully deburred and all plastic shavings removed from the enclosure Replace the PCB using the two sc
43. weather proofing fitting a suitable gasket rubber should be used when mounting on a BESA Conduit box fitted by M4 screws through holes provided on rear of fitting Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk INSTRUCTION REF IN176 ISSUE No 1 DATE 2 01 08 DARRY Page 43 of 59 TELEPHONE SERVICE 44 01332 875665 FAX SERVICE 44 01332 875536 Gas Interlock The gas interlock is a safety system that links the ventilation system and the gas solenoid valve The gas solenoid valve will remain shut and stop gas flowing to gas appliances if the ventilation fans are not operating or if the air flow is below a minimum level The solenoid valve will also shut if the system senses a gas leak anywhere along the pipe work or gas appliance The system checks this by monitoring the pressure in the pipe work over 60second period Low pressure indicates a leak and the interlock system cuts the gas supply Parry are now offering canopies sold complete with gas interlock systems For use with canopies with internal centrifugal fans The diagram below shows the items that are included as part of the Gas interlock Light Switch Pressure Switch system Fan Speed Controller Interlock Controll 3 ontroller zej A IW Gas Soleniod Gas Pressure Valve Transmitter Parry Group Limited Town End Road Draycott Derby England DE72 3PT WWW parry co uk

Download Pdf Manuals