Guardian Access Control System
Contents
1. 06 14 Setting the Keypad Device ID 2 00 000 ccccc cece cece eeeeees 15 Mounting the UltraConverter Junction Box 15 Keypad Wiring Diagram 0 0 0 00 cccc ccc ccc nec ec cece eee 15 QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 UltraConverter Connection to the PC ccc ccaceecceeeeeeaeeees 16 UltraConverter Grounding Diagram ccceeseeeeeeeeeeeeeeeeees 17 UltraConverter to Guardian Keypad Connection 00000e 18 LEF 3 Intercom Connection ccccc cece eee eeee eset eeaeeeaeeesees 19 Final Hardware Check LISt 0 00 ccccccccc cece eccneceeeeeeee nee 20 Establishing Communications for the First Time 20 Computer REQuireMents cccceceeecceeeeseeeeeeeaeeeaeeeanes 21 Working with the Guardian Control Panel 00eeeae 22 Trouble SHOOUAG iircsccsae tasacenccaainanterostsienahinacap on waibisbatioiteeatinn 40 WITFAC ORV CCT oaee E E 40 Checking Splices and Terminations 0 0000000000 40 Guardian Warranty Activation Instructions 41 ACUVAUODFOLM Sayona a a nnd een aattintnada 42 Required Grounding PICtures ccccecceee cece cesses eeaeeeeeeeaees 44 Technical Support Departmenit 0 0 ccccccccc eee e eee 47 QuikStor Security and Software 3 6613 Val
2. Q q St Since 1 F Security and tor Guardian Access Control System Installation Guide Minasa 6613 Valjean Avenue Van Nuys CA 91406 www QuikStor com Phone 800 321 1987 Fax 818 501 5785 Contents Introduction 4 Tools Needed For Installation 4 Recommendations for Wire 5 O oct E saath ow EA 5 18 2 OAS SINCIGCG erua art TEE I comusenianeceneaanes 5 FRG 20D E TE E E I EA S E T 5 RE a A A 5 Wiring Requirements 5 ONDO sas ers E A A 5 PICO Sissies ace E E ey eleeieea nalts aeemia te 5 Daisy Chaining and Star TOpOlOG cccceeeeeeeae cease eens 5 BNC Grimps and COuUpICIS goes cccccensscereperteuvessonsonePieabiaeiees 5 Pre Installation TIDPS 0 0000ccc ccc ccc cece ccc c cece cence nee enaes 6 Conduit Requiremenits 0 c0ccccccc cece ecce eee eeeeeeeees 7 Typical Gate Conduit Layout cccccecee cece eee eeeeeeeeaes 8 Installation Steps 0000 00cc cocci c ccc cece eee e cence een eee eenees 9 WIE P ae hacen a0 Scceannuunutsciuntadtentnnsanninamoecantseneaanieanaesneaetete 9 Polycarbonate or Aluminum HOuSIng ccceeeeeeeeeeenees 10 WOUNTING Goose NOCKS 22 t52schuetieu ees eames nevenauaalereagads 10 Keypad Mestalla lOM ucciutesvacats tones aaa he deemouar eid 10 Lightning Protection Overview aaaanaaan 11 Keypad Wiring Breakdown cccccccccc ccc ecc eee eeeees 13 Wireless Keypad Overview and Setup
3. 818 501 5785 k Guardian Keypad Warranty Activation Each new Guardian keypad comes with a seven year warranty if purchased inside of a Polycarbonate housing This warranty includes damage that may occur from strong electrical surges such as from lightning To take advantage of this extended warranty you MUST fill out and return the following activation form for EACH Guardian keypad that is installed PLEASE NOTE Though the Guardian keypad has an extended warranty the UltraConverter still carries a one year warranty but does include damage that may occur from lightning The Surge Boards are meant to act as fuses for severe electrical surges and are NOT covered under warranty Guardian keypads purchased in Aluminum housings are covered by a one year warranty Guardian Activation Form Following are two Guardian Activation Forms to accommodate a typical two keypad gate system If you have more than two Guardian keypads to activate you may make a photo copy of these forms or contact your QuikStor Account Representative for additional copies via email PDF or USPS Required Guardian Installation Pictures To complete the activation of your Guardian seven year warranty you must not only complete the following activation form but also submit pictures showing the following e UltraConverter installed in the office with the supplied Grounding Plug properly plugged into a 3 prong U Ground wall outlet DO NOT plug the Grounding Plug
4. Note that the QuikStor typical conduit layout drawing is merely a suggested guideline and can be deviated from or done in other ways based on your own personal experience In no way does QuikStor accept any liabilities for mishandled conduit runs improper conduit sizes improper interpretations or misused guidelines based on this layout By following these suggestions you should be well on your way to a quick and easy installation of your new QuikStor access control products QuikStor Security and Software 6 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Conduit Requirements O A minimum of one 3 to 1 conduit is needed from the office management area to the gate operator junction box or Christie box O A minimum of one conduit to each keypad stubbed up approximately a foot above grade is needed QO A minimum of one 3 conduit is needed from the junction box or Christie box to the gate motor for the relay control wires if your layout does not allow stubbing up next to the gate motor Note If the keypads have cameras it is necessary to use 1 conduit or larger for the main run from the office The next page contains a sample CAD layout for a typical QuikStor conduit layout Note that the QuikStor typical conduit layout drawing is merely a suggested guideline and can be deviated from or done in other ways based on your own personal experience In no way does QuikStor accept any l
5. Power O 12V red wire of 18 2 unshielded wire O GND black wire of 18 2 unshielded wire NOTE there is an auxiliary 12VDC terminal next to the power block that can be used to feed 12VDC power to a pinhole camera or other keypad Please be sure to calculate voltage requirements before using this power block as voltage drop could negatively affect the operation of the keypad Relay O NO Normally Open red wire of 18 2 unshielded wire OR O NC Normally Closed red wire of 18 2 unshielded wire O COM black wire of 18 2 unshielded wire NOTE The choice to use Normally Open or Normally Closed will be based on the type of gate motor you have or type of access control device you are controlling Intercom Optional O STN red wire of 18 2 OAS shielded wire O COM black wire of 18 2 OAS shielded wire L SPK the two 18 gauge speaker wires will be pre wired from QuikStor to the two SPK terminal locations If you need to remove them for any reason QuikStor Security and Software 13 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 they are interchangeable and you can place either wire on either terminal without negative consequence Wireless Keypad Communication The new Guardian Series access control system has the ability to communicate wirelessly This is a great option if conduit runs are not possible you are in a high lightning area and wish to reduce wiring exposure or if you simply
6. QuikStor Security and Software 39 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 o After Exit Minutes how many minutes after closing master closing hours are tenants allowed to leave the facility using the exit keypad o One Code you can assign multiple gate codes to each unit however if you prefer to only have one code per unit you can lock down this feature by changing this variable to Yes By default it is set to Off o Welcome Screen Interval your Guardian keypads allow you to have alternating welcome messages allowing you to convey more information to your tenants For instance you could choose to only change the bottom line and alternate between the current time date and the current temperature Select Yes to alternate messages or No to have a single welcome message o Speaker Volume adjust the speaker volume for intercom communication or audio feedback o Reset Keypad this variable allows you to automatically have a keypad reset if communication is lost for anytime between 10 to 60 seconds using the drop down box This variable should always be set to Deactive unless instructed by QuikStor Technical Support Increment Onsite Counter W for Access Doors _ o ceil Access Door Elevator Onsite List if the checkbox is selected the onsite list will be incremented for access door and elevator keypads If unchecked the onsite list will not in
7. may choose to add a small fan or heating element inside of the keypad housing The fan helps keep the inside circuitry cool in extreme heat environments The heating element is for extreme cold climates where freezing could occur on the keypad keys Select Fan to enable the fan feature or Heater for the heater feature on the drop down menu The necessary hardware must be installed inside the keypad for these features to work Tail lock Set to Yes Always if you Tail Lock Yes Only During Master Gate Hours Want to lock a tenant in that did not enter their code at ESA the entry keypad Enter a Yes Only After Master Gate Hours No Never if you would like es Always ee 7 UE to allow tailgaters out of your facility at any time You can also only lock them in during certain times For instance if you only want to lock them while the manager is on duty select Yes Only During Master Gate Hours conversely if you only want to lock them in after normal office hours select Yes Only After Master Gate Hours Exit gate activity will show up as Tail Out or Tail Lock in your QSX activity window based on which option you choose above After Exit Grace Period Day how many days past their paid to date do you want to allow tenants into the facility A specialized message will come up on the entry keypad notifying the tenant that he is past due and needs to pay his rent now
8. 91406 Tel 1 800 321 1987 Fax 818 501 5785 Trouble Shooting lf you have attempted to establish communication with the keypads and have failed your best course of action is to check the system one component at a time Here are some easy steps to verifying that the hardware is setup properly UltraConverter E 0 Oboe Is the USB communication cable from the UltraConverter plugged into the management computer Does the UltraConverter have the green LED power light on Is the Power Reversed light on If so swap your power wires Is the PC Communication light a solid green Is the System Status light a solid green If it is flashing red continue troubleshooting Are the data communication wires firmly fastened to the terminal blocks and unbroken Checking splices and proper terminal to wire termination E OOOO Oo Make sure that you have observed the proper termination guidelines from the diagrams included with this manual lf there are any wire splices make sure that they are not broken or grounded which can cause a lack of communication to the UltraConverter Make sure that all data wires inside keypads are firmly terminated Make sure that the data wires are not grounded or broken Check to make sure the keypads have power Check the voltage at each keypad Each keypad should have a minimum of 11 70 volts DC QuikStor Security and Software 40 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax
9. QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Inside of Intercom Base si o iiini connect hee a E e E E aS ao o all 162 60 Al ell el a el allio E L ee e EN ES E eS eo oF Soo E ory Jj orl fn re ee ee ee al ih j tai x tht m ar he r ES ol Ble Hre wm Of gt 8 Sag i a er g DORAN Hi EAFA OH LEF 3 Diagram WuikStor Fii yaja Be Tom Moya CA eT Phora 6se 304 1807 Pag 1 of 1 QUESTOR SECURITY AND SOFTWARE THES G0 OME NT ARD THE INP OF ATOM HEREIN Ae PROPRIETARY DAT OF OUST OR THE IHFORPRTION DESOLOSED IM THES LLUN EAT HAr MoT Be REPRODUCED VWATHOUT WRITTEH PERM ESE FHC Pi CURE Tas 19 QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Final hardware check list Before setting up your gates within QuikStor Express QuikStor s Management software there are items that should be complete If the site is not using QuikStor s Express management software please follow the documentation for the software used at that site Contact QuikStor Support if there are questions not answered in that documentation Below is a basic checklist that will aid you Please check off each item as it is completed L L L Your gate and keypad hardware is completely set up Your keypads are plugged into the UltraConverter IMPORTANT do not c
10. Sensor PIE Active iw Click above to start the diagnosis Sister Log Ae F201 22026 PM gt Information gt Creating Main DataModule Aer e011 226 28 PM gt Information gt Connecting arral 2 28 28 PM gt Information gt Upgrading Database e201 2 28 28 PM gt Information gt Upgrade Finished eer 2011 2 28 28 PM gt Information gt Files Folder cc ar01 2 28 28 PM gt Information gt Make Command File Ignored Because ALLCON ts not Running C arra 2 28 28 PM gt Information gt Make Command File lgnored Because ALLCOWN is not Running M A 2f 2011 2 28 28 PM gt Information gt Make Command File Ignored Because ALLCON ts not Running ww 7 rr Non QuikStor Management Software Integration Though the tightest integration is between the Guardian Access System and QuikStor Express Management Software we recognize that some of our clients will choose to use different management software For those clients we built in additional features and functionality to the Guardian Control Panel such as real time gate sensor activity reports and ability to open a gate via the software To use these features simply open the Guardian Control Panel and click on the report or feature you choose to use Beyond these functions everything else is identical as if you were running QSX though some features may not be supported by your management software QuikStor Security and Software 39 6613 Valjean Avenue Van Nuys CA
11. a replacement housing to facilitate replacement The Surge Board is NOT covered under warranty as it is designed to act like a fuse to protect your keypad investment from severe surges The UltraConverter in the office is covered under our standard one year warranty with the same policy for the Surge Board as with the keypads In no way will QuikStor be held responsible for any damage or injury to person or property QuikStor s sole responsibility under this warranty is to provide a replacement keypad circuit board The seven year warranty begins at the time of activation as described in this agreement The warranty period does not start over after a replacement keypad is provided by QuikStor and is only in effect from the activation date If a site experiences a device failure other than Surge Boards QuikStor may require that an electrician or lightning professional evaluate the grounding Provide printed or digitally emailed photographs detailing every wire connection noted above and label each picture with your facility name and keypad serial number Your keypad warranty is activated once these pictures a signed copy of this agreement and a printed or faxed QuikStor gate activity report listing at least 20 consecutive accepted access codes are delivered to and signed off by senior QuikStor management By signing and dating this page you agree to all the above terms listed herein Facility Name Facility Address Client Printed Name To
12. and Software 34 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 o Relay this is the relay on the Guardian Relay Board that is triggered when a tenant enters a successful code at an elevator When the tenant enters the elevator car they will only be allowed to go to the floor that their unit is located on The Relay section allows you to assign the following o Relay ID select the ID address of the relay board you are connecting to your Guardian access network Remember that the relay board is part of the keypad data bus so there is no need for a dedicated data line between the relay board and UltraConverter You may daisy chain it along with the keypad data o Relay Description this is where you will write a description for your relay board This is particularly helpful when you have multiple relay boards around a large facility performing various functions such as elevator control sirens etc o Relay Setup this is a free form space that allows you to make notes as to what each relay is doing For example Relay 45 siren 2 The Relay Trigger section allows you to setup specific relay boards amp relays to control various devices outside of the QuikStor system The settings include the following Relay Trigger Site Active Relay Board o Relay Board select the relay board that you would like to use to control your external devices o Relay ID select
13. i 7 ee Grace Perio Fe reer Closed Deny ia Jos Zone Deny Line 4 i Time Dery Proceed to UNIT X Ead Code Sass Intercom NAME Prints out as much of the tenant s KEYCODE NAME field as possibl Special Lack Deny PTO Prints out the paid thru date in MM ODA YY format as reported by Halid ay BAL Prints out the unit s current balance as reported by the most recent A HOURS Prints out the unit s access hours for the present day ATIME Current time of the day in HH MM MPM format Meant for the w DATE Current date in MMOD format DOW Current day of the week 3 letter abbreviation TEMP Current interior temperature of the keypad in Fahrenheit The F s UNIT Prints out as much of the unit s UNIT field as possible ill All Messages with Default Values Below is a list of merge field style variables that you can use with your keypad messages to help personalize the messages your tenant receives NAME Prints out as much of the tenant s Last Name as possible PTD Prints out the paid thru date in MM DD YYYY format ABALA Prints out the customer s current balance gt gt gt gt UNIT Prints out the customer s unit number gt HOURS Prints out the customer s access hours for the present day gt RTIME Current time of the day in HH MM AM PM format Designed for the welcome screen only QuikStor Security and Sof
14. trying to establish communications with your keypad network Front of Ultra Convener Back of Computer QuikSter ULTAA CONVERTER BrSTEM Starla i pica r N QuikStor y aai ff i 6 vous USB Port I Pes REVERSED Hi Thos USB to Ultra Converter Cable QuikStor AA Becuri and Software THIS DOCUMENT AND THE INFORMATION 6614 Aon ae HEREIN ARE PROPRIETARY DATA OF QUIKSTOR eee Van Nuys CA Sb THE INFORMATION DISCLOSED IN THIS 7 Aa A BI seer a i i n E RLE bya Ultra Converter to Computer B1S 222 2000 Pages LC DOCUMENT MAY NOT BE REPRODUCED E ELRE ton AA pa i ae a a NF Aran paS roa 8 S F0 a 78S FAN Rev Daie Meee WITHOUT WRITTEN PERMISSION FROM Ma e QUIKSTOR lIlustrabed Bw JoEre Miorcude QuikStor Security and Software 16 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Preferred Method Alternate Method Plug directly into wall outlet not power sirip of surge protector Grounding Rod amp ft tall amp 578 thick 3 Ground Clamp Ground Rod gors through here Wall Outlet Utra Converter MOTE Though mest offices will not have a grounding rod or cold water pipe available for grounding we highly recommend that method over simply plugging it into a local outlet However if that is all that is avaiable we do provide a grounded U Ground outlet thal you can use Do NOT use this system without an Earth Ground wire securely connected to a
15. want reliable communication that will never require maintenance amp replacement as wire typically does over time When using the wireless radio system you will not use a Surge Board for data communication Instead you will use a Radio Board with a small radio amp antennae connected to it The standard radio antennae combination is rated at 800 ft line of site Obstacles will reduce this range The only configuration required when installing the wireless system is to flip dip switch 8 from OFF to ON up position on the bank of DIP switches See drawing below for clarification if needed This setting will be pre configured by QuikStor if the component was ordered with a radio However if you are changing from hardwired to radio you will need to change this DIP switch setting which can easily be done in the field with a small flat head screwdriver The radio board and antennae should be pre installed by QuikStor Simply power the wireless devices and they will automatically detect each other There are RANGE and COMMUNICATION COM LEDs located on the Radio Board to assist you during setup In addition there is a power LED to signify that the radio is receiving the necessary power NOTE Only the UltraConverter can have a Surge Board and Radio Board installed at the same time The Keypad and Relay Boards must only have one or the other installed as there is no need to ever have both on a single board There is no problem mixing and matchi
16. your new keypad system Earlier versions of USB were extremely slow and result in slow or intermittent communication between your PC and access control system Most computers purchased since 2000 will have USB 2 0 already installed Trying to establish communications for the first time The first thing that you will do is have QuikStor Technical Support connect to your PC so that they can load and setup the requisite software They will be loading two main software programs The first is the interface program that runs in the background and communicates with the keypad system This is called Allcon The second is the user interface program called the Guardian Control Panel or GCP for short This is the program that you will use to setup your customized site settings Now that the software is loaded onto your machine you need only setup up those variables that are unique to your facility such as time zones grace period etc If you are using the Quikstor Express QSX management software you can easily configure these settings by following the instructions in your QSX manual or help files lf you are using different management software that integrates with the Guardian Access Control System you will set all of these variables in the Guardian Control Panel You will also need to keep this program open if you wish to view real time gate activity QuikStor Security and Software 21 6613 Valjean Avenue Van Nuys CA 91406 Te
17. 01 5785 o Open Access Point Momentarily when you click this button you will select which keypad you want to trigger to open a gate access door etc The relay will pulse momentarily based on the variable setting on the Variables tab This is a handy button to use to let in a vendor or other person that does not need a code o Open Access Point Hold Open similar to the above command but this one will actually hold the relay closed for the chosen device You would use this if you wanted to hold a gate or access door open The device shows a blinking orange LED indicating the device is being held open by the software o Close Access Point use this button to open the relay for a device that has been held open o Silence All Alarms this button will only appear if you have QuikStor wireless door alarms installed at your facility Clicking C sems OY this button immedi ately q uiets jija E all sirens at the facility o Refresh click this button to refresh the keypad list and gate activity list The right frame of this tab is where the real time gate sensor activity will be displayed When an event happens it will list the name of the tenant unit number date time of the event which keypad the event happened at and a description of the event such as Let In Below the gate activity window are your Activity Filters Here you can choose to display Show All Only Gate Activity or On
18. 09081817 am 1 Late Deny Mae WO apaoeietess MoO settings Gans iB 1 02 0908 0612 am O Motion Alm Wayne 1B 11 02 09 07 58 09 am 0 Motion Alar vor EO Hmveerion 0 hale EE Hegal iem The screen to the left shows a typical 3rd Wayne 1B 10 31 09 08 39 47 am 0 Motion Alarm a n esse Pe Morena ors Basta o Maman party management integration that Cr Yor t ieee ete ie apne T3 pm otion arm eee ee e tannin gt sams displays gate activity non tenant codes se ee SA Monitar Gate Activities Ctivity riter fi Refresh Show All Only Gate Activity Only Sensor Activity and repo rts At the top of the Guardian Control Panel are five buttons that are global to all tabs QuikStor Guardian Control Panel QuikStor Security Software QuikStor Security Software C o O Reports Mon Tenant About User Guide nad Messages Sensor amp Siren Zone Variables Elevator amp Relay Diagnostics They are o Save All after you have changed a setting or group of settings click this button to send the updated information to the keypads QuikStor Security and Software 22 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 o Reports click this button to run activity reports There are four reports that you can run from the Guardian Control Panel o List of All Gate Codes o Gate Codes for a Selected Unit o Gate Activity o Gate Activity for a Selected Unit Note Th
19. 8 23 25 am 2 Tail Out Brandenburg an 1102 09 08 23 24 am 1 Grace Pernod Wi ayn 1B 11702709 08 19 22 am Motion Alam Cargo te 11702709 08 18 20 am 2 Let Out Cargo JE 11702709 08 18 19am 1 Grace Period Invalid Code 11 02 09 08 18 18 am 1 Invalid Code Gutierez 10 11 02 09 08 18 17 am 1 Late Deny Gutierez 1301 11 02709 08 18 16am 1 Grace Period Invalid Code 17 02 0908 16 15 am 1 Invalid Code Carga 1C 11702709 08 18 14 am 1 Grace Pernod VW ae 1B 11 02 09 08 06 12 am Motion Alam Wi ae 1B 11 02 09 0 56 09 am Motion Alarm Wi ane 1B 11702709 07 48 06 am Motion Alam Wayne 1B 1102 09 07 23 03 am Motion Alam Wayne 1B 11702709 07 20 00 am Motion Alan Wayne 1B 10731709 08 43 50 am D Motion Alam Wape 1B 10731709 08 39 47 am Motion Alam f Open peere POR Klorrentariiiey Wayne 1B 107 307 03 U5 32 42 pm Motion Alam a aa 1E TUF SULUS US 26 3 pm U Moton Slam F l a Wayne 1B 10 30 0905 19 36 pm oO Motion Alarm Open Access Point Hold Open wayne 1B 10 30 09 05 15 33 pm 0 Motion Alam Wayne 1B 10730709 05 05 30 pm O Motion Alam if CEIETEEEST PRII irauna 1E LAA NAAR IF nn A hdotion flara l RA Monitor Gate Activities Activity Filter a Show All 0 Only Gate Actyity Only Sensor Activity B Below the device list there are five buttons to control immediate actions Those buttons are QuikStor Security and Software 24 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 5
20. 9 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 The different types of keypad installation Guardian keypads can be used to open gates access doors and or restrict elevator control In this manual we focus on the most common keypad installations which are gates Elevator control setup can be found in the Guardian Series Relay Board Installation Manual Access door setup is nearly identical to gates except in two respects First an access door keypad is usually mounted on the wall next to the door versus a gooseneck The hardware used to mount the keypad will depend on the material you are mounting to concrete drywall etc The second difference is that instead of connecting the dry contact relay of the keypad to a gate motor it will be connected to either an electric door strike or magnetic lock Since the relay on the Guardian keypad is a dry contact the voltage you choose for the door hardware control does not matter though QuikStor recommends staying with a 12VDC or 24VAC lock system Review the installation instructions for your particular door hardware on how to properly power and wire your hardware to the Guardian keypad relay Polycarbonate or Aluminum Housing The QuikStor Guardian keypad is offered with a choice of two housings e Polycarbonate this is a cutting edge design that provides a corrosion resistant and surge resistant blend of high strength polycarbonate It provides the same vanda
21. Ensure the keypad gooseneck is level it may be necessary to shim the bottom of the gooseneck in order to achieve a level appearance L Place gooseneck base cover on then proceed to installing the keypad L L Keypad installation QuikStor provides carriage bolts to mount the keypads to the back plate of the gooseneck Mount and level the keypad to the gooseneck utilizing the pre drilled mounting holes and proceed to terminate the wiring to the keypad 12 i pais e GOOSENECK BASE a i ANCHOR BOLTS 4 EACH COMCRETE PAD 1S ees a hg i i I a EARTH LE EL EARTH LEWEL 34 CONDUIT Electronics such as access control keypads must endure harsh environments often including lightning and other power surges This is why QuikStor has designed a revolutionary module called the Surge Board This board goes on all access a curity and Software 11 nue Van Nuys CA 91406 QuikStor AN 987 Fax 818 501 5785 control equipment that is hardwired versus wireless including keypads relay boards and the UltraConverter This device acts like a circuit breaker or fuse between the device it is protecting and the incoming data wiring Simply snap it onto the device it is protecting and connect the data wires to it by using the removable wiring block In the event of a power surge the Surge Board acts like an automatic circuit breaker by momentarily breaking the data conne
22. al notice with this tenant Or do you continue with the legal process as if they had not made any payment P Release the Liens and go back to square one Additional Charge Labels Continue the legal action without change C Evaluate each situation on a case by case basis QuikStor Processing LM Strict First Of The Month Facility Rent Due on 1st of month only Mail Service 7 ra Ps Automatically apply credit to Rent during overnights If someone pays future rent should move the paidto Gai yation date way into the future or should move the paidto amp i date one month and put the excess funds into credit E a 5 More Info Source List Profile List I Use Variance List Last Reservation Number 76 4 Last Receipt Number 483 24 IV Enable Truck Rentals Help Video Help f Save amp Exit x Cancel QuikStor Security and Software 20 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Minimum Computer Requirements Operating System Windows 2000 XP Vista 32 64 bit and Windows 7 32 64bit USB Port A free USB port is necessary to connect your new Guardian System to the management computer Memory RAM o Windows 2000 256MB or higher o Windows XP 512MB or higher o Windows Vista 1GB or higher Though any USB port will work we strongly recommend using a USB 2 0 port to provide the fastest connection between the PC and
23. ansmissions O RG 59 keypad cameras under 700ft LO RG 6 keypad cameras above 700ft NOTE If you are installing a keypad system with wireless data communication disregard the 18 2 OAS data wiring and references to the Surge Board in this document Be sure to read the wireless section on page 13 Wiring Requirements L 12 VDC runs should be no longer than 200ft please note that the keypad needs a minimum of 11 70 volts DC in order to operate at an optimum service level O Data runs over 1000ft must use 18 gauge wire or larger to ensure proper signal strength is met O Earth Ground wiring grounding is most effective at short distances as electricity travels to the point of least resistance All grounding locations should be 6 or less from the Surge Board L Splices made on 18 2 should always be done with wire nuts or using a Suitable termination splice block O Any splices made in underground junction boxes or in an area where water or other foreign materials could short the wires they must have a wire nut or similar connector filled with silicone or like material Keypads may be daisy chained or configured in a star topology BNC coax crimps should be used at all terminations and splice points when working with video coax O BNC couplers should be used at all splice locations when working with video coax it is recommended that you wrap the splice with electrical tape to avoid grounding the video signal OO QuikStor Se
24. ata wires on the appropriate terminal blocks Please note that the drain wires from the Surge Boards at the keypads are NOT connected on the UC end Only the A and B terminal wires are connected on the UC and the GND terminal is left blank Be sure to coil and tape the drain wires coming from the keypad s GND terminals as to make sure that they do not touch other grounding locations or each other This can cause a ground differential and increase the possibility of lightning or surge related failure Terminate the 12 VDC power supply wires Terminate the USB PC communication cable from the UltraConverter to an available USB port on the management computer O PLEASE PAY SPECIAL ATTENTION TO THE GROUNDING REQUIREMENTS FOR THIS DEVICE A detailed diagram is provided on page 16 Not properly grounding this device can cause premature failure O Please see wiring diagrams on pages 15 18 if there are any questions or concerns O O QuikStor Security and Software 15 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 After you mount and power up the UltraConverter and keypads you are now ready to try and establish communication with the keypads and setup the gate operation parameters The following pages contain typical wiring diagrams for QuikStor keypads and office equipment Please connect all of the appropriate wires to the gate operator keypads converters computer and move on to the final check list before
25. ay is set at a default of 6 seconds and should not be changed unless directed by QuikStor Support The main gate relay is set by default to 5 seconds This setting is fine for most gate motors however you may want to modify this setting if you are controlling an access door to hold the door open longer with the keypad relay Lastly there is an elevator setting when controlling elevator relays on the separate Guardian Series Relay Board The default is to hold the QuikStor Security and Software 3 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 relay for 45 seconds but again this can be modified to suit your facility s needs Master Gate Hours this is where you select the gate hours for your entire site Select the opening time in the first box and your closing time in the second box This time is what other variables reference such as siren duration or after exit settings Tenant Offsite Minutes there are two fields that determine how long a tenant can be onsite before they are moved offsite by the system The first is how long after they entered their code at an entrance keypad and the second is how long after their door is closed only applicable to sites with wireless door alarms Both of these settings are used to assure that the system is kept current and or that a unit is re armed if someone tail gates out of the facility Climate Fan or Heater depending on the climate you live in you
26. crement See the Variable screenshot on the following page QuikStor Security and Software 33 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 y QuikStor Guardian Control Panel QuikSter Security Software QuikStor Security Software 6 C o O Q Reports Non Tenant About User Guide Gate Activity Z W V Diagnostics Relays Sec Df Site How many minutes after each activity Intercom E should mark a tenant as off site Fl do not get a code out at the exit Gate 5 Door Close 120 Elevator 45 Gate Entrance 120 Master Gate Hour Climate Open 08 30 Fan or Heater Heater Close 22 00 Temperature Trigger 40 Tail Lock yee Only During Master Gate Hours v Speaker Yolume 3 Low Medium High Delinquent Lockout Grace Period In Days R amea a k e aa A r ek a a n After Exit Minutes 15 EES Increment Onsite Counter OneCode Ho Tw Za for access Doors _ R Elevators Welcome Screen Interval 3 Reset Kerpad 7 After Communication Loss Deactive m v Elevator amp Relay Setup use this tab to setup elevator and relay boards Including using the Relay Module to control lighting perimeter beam arming etc The Elevator section allows you assign the following o Floor select which floor this keypad and relay will allow access too o Keypad ID select which keypad a tenant would use to access a given floor QuikStor Security
27. ction between the device and the wiring When the surge has dissipated the connection is restored and communication resumes as normal In the event of an extreme lightning related or other power surge the Surge Board sacrifices itself to protect the device it is attached to At that time you simply remove the sacrificed one and snap in a new Surge Board similar to an automobile fuse Surge Boards are inexpensive and easily replaced without the need for expensive component replacements IMPORTANT PLEASE READ Your new Guardian Series Access System has been through extensive testing for surge dissipation and lightning resistance Through tests ran at independent laboratories as well as in the field it has been determined that having a grounding rod driven into the ground near each keypad stand will provide the highest level of protection from electrical surges When combined with the above mentioned Surge Board and 12 or larger solid conductor ground wire your keypad system will greatly improve the possibility of surviving a nearby lightning strike or other electrical disturbance Simply connect one end of the grounding wire to the Earth Ground screw of the Surge Board and the other end to a grounding clamp around the grounding rod For added protection it is also recommended to run a separate grounding wire between the base of the keypad stand and the grounding rod lf a grounding rod is not available you may run the same grounding co
28. curity and Software 5 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Pre Installation Tips E OO Check the gate motor for a 120v outlet This can provide you with an excellent local source of power for your keypads and prevents severe voltage drop issues Confirm that the power outlet has a constant hot connection and is not on a timer or photocell device Plan on running a couple of spare 18 2 OAS Shielded wires This can help in case you forgot something or need it for future add ons to the system Keypads should be on their own individual power supplies QuikStor always includes enough power supplies at the time of the sale to meet these requirements If you find you don t have enough please contact QuikStor or your sales representative immediately QuikStor recommends and provides a switch that bypasses the keypad system in the event that the gate needs to be held open for an extended length of time Please keep this in mind when you are planning your wire pulls An extra 18 2 cable between the office bypass switch and gate motor will be needed Please make sure your client has installed the QuikStor Express software and data entry have been completed before you head out to complete the installation Make sure all conduit is complete before starting the job Verify that all conduits follow a logical pattern as suggested by the QuikStor typical conduit layout CAD drawing included in this document
29. day s Date Client Signature QuikStor Printed Name Today s Date QuikStor Signature QuikStor Security and Software 43 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 UltraConverter mounted in the office and properly grounded QuikStor Security and Software A4 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Keypad Picture showing the ID and Ground Wire attached to the Surge Board s Earth Ground QuikStor Security and Software 45 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Keypad grounding wire connecting to a ground rod QuikStor Security and Software 46 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Still have questions Call us QuikStor Technical Support Department 1 800 321 1987 Support Line 1 818 501 5785 FAX Support quikstor com QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 47
30. during the installation and helps you or others later during service Wire Pulls Pull the main wire run leaving enough slack to splice wires properly The main run usually consists of the following wire Typical two keypad system with intercoms L One 18 2 OAS Shielded for data communications LO One 18 2 for 12 VDC for each keypad this is if you have not chosen to power keypads locally from the gate motor L One 18 2 OAS Shielded for intercoms to each keypad Must be home run back to the office base station L One 18 2 for bypass or gate over ride directly to gate motor terminals L One or two spare 18 2 OAS Shielded for future use An additional 18 2 for power and RG 59 RG 6 for video data will be needed for keypads with cameras The keypad will need the following wire pulled to it from the common junction box or gate motor One 18 2 OAS Shielded for data One 18 2 for 12 VDC One 18 2 for relay One 18 2 OAS Shielded for Intercom Optional one for spare or required KNOX key switch f you are required to install a KNOX key switch QuikStor advises that it is best to run a separate wire directly to the gate operator keeping the QuikStor system independent of the KNOX switch OOOOO An additional 18 2 for power and RG 59 RG 6 for video data will be needed for keypads with cameras Pull keypad runs leaving at least 5 of extra wire from the finished grade to thread through the gooseneck QuikStor Security and Software
31. e QuikStor Security and Software 36 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 gt QuikStor Guardian Control Panel QuikSter Storage O O rai Ey Reports Non Tenant About ty Zone amp Keypad Keypad Messages Sensor amp Siren Zone Variables E nest Trigger Time Zone _ RelayBoard Relay ID TimeZone Time Zone OnSite n PEN 2 l 1 Ferimeter Beam Sc Active Active pee Deserfon ___ F 1002 Perimeter Beam Schedule moO 7 H is x H A Zone ID 100 Description iahting Relay Board 7 F Lighting Schedule 1D Description 0000 O Open Close ela Relay Board Monday 07 00 13 00 F Tuesday 07 00 13 00 Wednesday 07 00 13 00 Ha 4 P P r a Thursday 07 00 1 3 00 Friday 07 00 13 00 E i a 13 00 Floor Keypad ID IR elay Saturday i i td be 1 66 Sunday 07 00 13 00 Holiday 07 00 1300 7 P s v Diagnostics IMPORTANT THIS TAB SHOULD ONLY BE ACCESSED WHEN ASKED BY A QUIKSTOR SUPPORT REPRESENTATIVE PERFORMING FUNCTIONS IN THIS TAB MAY INCUR UNDESIRED RESULTS INCLUDING LOSS OF DATA AND SYSTEM INOPERABILITY One Click Diagnostic this button in the center of the screen runs a comprehensive diagnostic on your entire Guardian Access Co
32. e Reports button will only be available if you are not running QSX o Non tenant Code this button is only used for sites not running QSX It allows the manager to add a code for contractors trash pick up etc When you click this button you will see a screen like the one below where you can enter in a name code access rights and a keypad zone xi Fe Ee E I G EE E Hame l Kep Code Access Fight TA Keypad one ae gt Steve Weinstein T1665 Access if Delnquent within Hours Ba 10p Trash 3393901 Full Access 24r _ Tony Gardner eee Access if Current within Hours Normal Hours fa p Ea el p Hi zia m Ta ae Name Steve Weinstein Access Right Access if Delinquent within Hours Kep Code 71 BES Kevpad ane Ba 10p x Cancel All Changes o About this tells you the version of the software and a little bit about the creators o User Manual click this button to open a PDF version of the latest Guardian User Manual Below the buttons are seven 7 tabs that allow you to customize your Guardian Access System experience Gate Activity this screen gives you real time gate activity reporting functionality and status of each QuikStor Access Control Device On the left frame you will find a list of all of the keypads at your facility any relay boards and your wireless base station if you have one Next to each device will be one of the following indicators o Green a green LED indicates that this device is
33. e damaged unit is returned to QuikStor If the defective equipment is not returned within 14 days the client understands that they will be billed in full for the replacement parts QuikStor shall have the sole and final determination if a keypad failure is covered under this warranty v List the 1 10 digit serial number of ONE QuikStor Guardian Series keypad that you would like to activate under this warranty agreement This number is printed on a small white sticker located on the top of the circuit boards far right edge Keypad serial _________ _ v For this keypad initial every step that you have personally witnessed to be true This warranty is not in effect if any step has been skipped not initialed or was done incorrectly v The surge board s Earth Ground connection has a securely installed grounding wire of gauge 12 AWG or larger and is connected to a grounding source not more than 6 from the keypad circuit board An approved grounding source is a properly installed grounding rod or the base of the keypad stand Initials v The keypad has the GND drain wire properly connected to the keypad Surge Board but does NOT have the GND wire connected to another keypad or to the UltraConverter Initials What_is not covered under this warranty this warranty does not cover physical abuse vandalism or damage caused by vehicles The warranty only covers the actual keypad circuit board though QuikStor at its own discretion may send
34. grounding source OuikStor Security and Sottware 6614 Valjean Ave i 1 i p1 i BL R G22 200H ae A DOCUMENT MAY NOT BE REPROLICED Ultra Converter Grounding E AN T AE EA rence ae ha BER 30 37RF FAR Rev Dates 04 12008 WITHOUT WRITTEN PERMISSION FROM OUIK STOR Nlustratad Ay Jobo Mercade THIS DOCUMENT ANID THE INFORMATION HEREIN ARE PROPRIETARY DATA OF OUIRE STOR Drawing Descnptien i ET Van Nuys CA 9 Mae THE INFORMATION DISCLOSED IN THIS pie ht 17 QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 ris Tog of Uhra Converter a t al Fa I Ti T i Black Wire YETEN sTaTus poo AD QuikStor eon INEF GRE ha ran meso ran ca x Sct sus l DATA stare De mol connmatt EHO wire G from Keypad to Ultra Ga Back Wing Fad Virg mener Cul or wrap wire Surge Board attached here THIS DOCUMENT ANID THE INFORMATION HEREIN ARE PROPRIETARY DATA OF QUIK STOR THE INFORMATION DISCLOSED IM THIS Drawing Desonpticn Ultra Converter to Guardian Keypad Board DOCUMENT MAT NOT BE REPROCICED WITHOUT WRITTEM PERMISSION FROM QUIK SEN Guardian Keypad Goard with Attached Surge Board BE A GND EARTH ORGAO j aE EI EAEn QuikStor AN Security and Software 6614 Valjean Ave Von Huys CA S 1H BR MKH BER 30 3783 FAN lusirobad Ay JoErie Mertadi Pager Uil ew Daie HEDRE 18
35. iabilities for mishandled conduit runs improper conduit sizes improper interpretations or misused guidelines based on this layout See diagram on the following page QuikStor Security and Software 7 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Gate Keypad Configuration RBOLLARD INSIDE OF PROPERTY INSIDE OF PROPERTY EXIT KEYPAD EXIT KEYPAD BOLLARD DETECTOR LOOP O Gr TEC TLE LOOF e a l T DE m SATE ie GAFE gmi Pat Ce peat TE hi ry m os cH GATE MOTOR PTE METEN E j ee E ee E a E n a O mci GT GSS ca iia E u CONDUIT OE oe 114 O CONDUIT W PAD ENTAY KEYPAD ETAY KEYPAD OUTSIDE OF PACPERTY OUTSIDE OF PROPERTY DUAL GATE OPERATORS WITH AN ISLAND SINGLE GATE OPERATOR NO ISLAND DRAWING DESORE TIN ACCESS DEVICE SETUP QuikStor Security and Software 13008 Ventura Biwi Sherman Oaks Ci B42 Phhane 1 800 221 1987 79 Fou 4 504 5785 QUIKSTOR SECURITY AND SOFTWARE THS DOCUMENT AMD THE WFORMATIH HEREIN ARE PROPRIETARY DATA OF GUKSTOR THE NFCAMATKEIN DIBCLOBED IN THIS DCOLMEHT MAY NOT HE REPROOUCED WITHOUT WRITTEN PERMESI FROHM QOUIRSTOR sess 4 23 03 77 Renee Kaplan QuikStor Security and Software 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Installation Steps Installation tip It is always a good idea to label your wires with a Sharpie or wire markers This will assist you
36. into a power strip surge strip or UPS e Each keypad with the ID number clearly shown in the picture and the grounding wire connected to the surge board s Earth Ground screw e The grounding method for each keypad such as the termination of the grounding wire to a ground rod or other acceptable grounding source e Wireless systems that do not utilize surge boards only need overview pictures of each keypad and the installed UltraConverter Sample pictures showing what we need to see with the appropriate angles and zoom are below QuikStor Security and Software A 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 QUIKSTOR S GUARDIAN SERIES SEVEN YEAR KEYPAD WARRANTY Every QuikStor Guardian Series keypad sold in a Polycarbonate housing and verified as operational and properly connected per QuikStor s documentation requirements below will be covered by a SEVEN year warranty including lightning damage Should such a QuikStor keypad ever fail during the activated warranty period a replacement unit of comparable age and condition will be shipped via UPS Ground at QuikStor s expense The client may have the replacement keypad shipped at a faster rate at their expense To activate your new warranty simply complete a separate copy of this page for each keypad you wish to be warranted This warranty becomes void if the warranted keypad or its components are ever attached to equipment or wired in a manner tha
37. jean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Vp Please Read this Introduction before Starting Install Please take a moment to read through this introduction before installing your new QuikStor Guardian Series access control products This has been designed to save the installer time in the pre planning and installation stages This outline will cover all possible questions regarding minimum system requirements materials standards installation and trouble shooting tools in order to achieve a fully functional QuikStor access control system Please keep in mind that we have a fully trained and staffed Technical Support Department at your disposal that can assist you with questions or concerns during the entire installation process To reach the Technical Support Department please call 800 321 1987 8am to 5om PST Monday through Friday Tools Needed for Installation Fish Tape Electrical tape Wire Nuts Dolphin Connectors Phillips head screw driver Flat nhead screw driver Wire strippers Wire lube Wire markers Sharpie felt marker Hammer Multi Meter Socket Set Y2 Masonry Bit Hammer Drill OOOOOOUOOOOOOOO0 QuikStor Security and Software 4 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 QuikStor Recommends the Following Wire O 18 2 for all 12VDC Relay and Bypass wiring O 18 2 OAS shielded for intercoms O 18 2 OAS shielded for all data tr
38. l amp weather resistant protection for your keypad circuitry but with the added benefits of improved styling customized logo keypad lighting and integrated components When a Guardian keypad is purchased in this housing it is eligible for a seven year warranty e Aluminum this is our original design that provides a more traditional styling that many owners still prefer Due to its metal characteristics it does not qualify the keypad for the seven year warranty Other than the features listed above all other functions of the keypad Itself are identical between the two Mounting Goose Necks QuikStor provides 3 8 REDHEAD brand drop in anchors We feel that this is a suitable way to anchor our goose neck system but if you have an alternate method of anchoring products to concrete please feel free to use it QuikStor Security and Software 10 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 O To mount the goose neck use your fish tape to pull in the excess wire through the top of the goose neck Then mark the four holes on the level 18x18x18 concrete pad O Mark your hammer drills 12 bit to the desired depth and begin boring out your first hole O It is always helpful to anchor the goose neck with the first REDHEAD and check to see if your pre marked holes align Sometimes the drill may drift This will allow you to compensate on your next hole in order to get the proper alignment Tighten bolts
39. l 1 800 321 1987 Fax 818 501 5785 Using the Guardian Control Panel to Configure your Keypads Note for the purposes of this documentation we will assume that you are using QSX Many of these features will work regardless of which management software you are using but others are QuikStor specific If you are using different management software please follow that vendor s instructions and the Non QuikStor Management Software Integration section below IMPORTANT When entering codes into your management software or GCP please note that there can be no leading zeros in the gate code i e 000123 or apostrophes in the code name i e Bob s Code If you have existing codes in this format please correct them before using your Guardian system LALA tak rma E a Your daily operations with the gate will be i b 7 1 1 n n e done solely within QSX including one eyp eypa essages ensor ren lt one anabdies ev ator ela lagnostics gt n B B L L B EE ee A MaR TA reviewing real time gate activity and Exit Invalid Code 11 02 03 08 24 30 am 1 Invalid Cod a Ei wets n fees oe running gate reports However you will Brandenburg 24 11 02 09 08 23 27 am 2 Let Out Weinstein 2c 11 02 09 08 23 26 am 1 Let In d t th G di C t P t e ao Mem a aii need to use tne auaraian Lontrol Fanel to Wayne 1B 11 02 09 08 13 22 am 0 Motion Alarm P eeu z ff ee ee setup your initial gate configuration eta Do 2
40. ly Sensor Activity based on your personal preferences Remember that all of this activity will also be displayed in your QSX activity window v Zone Setup this tab allows you to define various zones as well as create descriptions for your keypads and relay boards Here to you can define Holidays and add additional keypads and relay boards into the system Let s walk through each section of this tab o Time Zone here you can setup time zones for your tenants managers and vendors Each zone is designated a number or Zone ID Below that you can enter a description for the zone such as Holiday Hours Finally there is a 7 day setup for both open and close times starting with Monday All times are in 24HR format If you want all of your hours for a particular zone to be the same as QuikStor Security and Software 25 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 O Monday s simply click the red down arrow button land it will automatically populate the remaining days with Monday s time setup Simply click the ADD or DELETE buttons at the bottom of this frame to add or remove any time zone You can also click one of the two checkboxes next to each day to designate that day as 24hour access or Closed All Day When designated 24hour the time fields will turn green When designated as Closed All Day the time fields will turn red Holiday most storage facilities will close their site d
41. nductor down the keypad stand from the Surge Board and terminate it to the mounting bolts of the keypad stand This is a much less effective solution and increases the possibility of lightning related surge damage NEVER install a keypad without a grounding wire running between the Earth Ground of the Surge Board and a solid grounding point See page 39 for further information on activating your Guardian Keypad Warranty QuikStor Security and Software 12 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Keypad wiring breakdown It is important to make strong mechanical and electrical connections Below is a breakdown of each wire wire type and wire color that is needed to make your new keypad operational Surge Board Data Communications O A red wire of 18 2 OAS Shielded wire O B black wire of 18 2 OAS Shielded wire O G drain wire silver unclad wire of 18 2 OAS Shielded wire only connected on the keypad Surge Board Do NOT terminate the drain wire onto the UltraConverter or allow it to touch the drain wires from other keypads O Earth Ground this wire is to be run between the Surge Board and a grounding point near the keypad gooseneck You may use a 12 solid ground wire between this terminal and a secure grounding point on the metal keypad housing keypad stand or nearby grounding rod preferred NEVER OPERATE YOUR KEYPAD SYSTEM WITHOUT THE EARTH GROUND CONNECTED AND PROPERLY GROUNDED
42. ng wireless and hardwired components at a single site however If you will be doing that simply confirm that you have both a Surge Board and a Radio Board installed on your UltraConverter QuikStor Security and Software 14 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Setting the ID on your keypad All Guardian keypads are pre configured at the factory with the proper ID 7 Do NOT change this ID in the field unless instructed by a QuikStor technician This bank of dip switches allow you to ID the keypad 7 O p so thatit can be recognized on the RS 485 data g network The ID schema is based on binary numbers i e 1 2 4 8 16 32 So if you want the ID to be 6 you would have dip switches 2 and 3 up equaling 6 Contact QuikStor Technical Support if you have any questions on addressing your keypad however by default your keypad will come pre configured to the correct ID per the facility contract i a ee Office Setup Mounting the UltraConverter Junction Box Mount the QuikStor junction box with the UltraConverter inside as close to the management computer as possible as the USB cable from the UltraConverter will need to plug directly into management computer A USB extension cable up to 50 may be used as necessary It will also need to be in an accessible place to use the gate bypass switch and for any service needs that arise Terminating the Wiring and USB cable O Terminate the d
43. not covered under this warranty this warranty does not cover physical abuse vandalism or damage caused by vehicles The warranty only covers the actual keypad circuit board though QuikStor at its own discretion may send a replacement housing to facilitate replacement The Surge Board is NOT covered under warranty as it is designed to act like a fuse to protect your keypad investment from severe surges The UltraConverter in the office is covered under our standard one year warranty with the same policy for the Surge Board as with the keypads In no way will QuikStor be held responsible for any damage or injury to person or property QuikStor s sole responsibility under this warranty is to provide a replacement keypad circuit board The seven year warranty begins at the time of activation as described in this agreement The warranty period does not start over after a replacement keypad is provided by QuikStor and is only in effect from the activation date If a site experiences a device failure other than Surge Boards QuikStor may require that an electrician or lightning professional evaluate the grounding Provide printed or digitally emailed photographs detailing every wire connection noted above and label each picture with your facility name and keypad serial number Your keypad warranty is activated once these pictures a signed copy of this agreement and a printed or faxed QuikStor gate activity report listing at least 20 consecutive accep
44. ntrol System QuikStor Security and Software 37 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Depending on the number of devices you have installed it may take up to 40 seconds to run all tests When it is done it will send an email to Support quikstor com as well as open an HTML file on your computer that you can review print or email to a technician In addition to the One Click Diagnostic button you will find the firmware versions for the UltraConverter listed in the upper right hand side of the tab and the latest logging events from Allcon are displayed at the bottom of the tab Here is a brief description of each section or button and what it does e Pollfor Devices does a scan of the Guardian network to confirm communication with connected devices e Reset UC resets the firmware of the UltraConverter e Port which port is the UltraConverter connected to on the PC e Sensor PIC this should be set to Active if you have wireless door alarms or Inactive if you do not See the Diagnostics screenshot on the following page QuikStor Security and Software 38 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 i QuikStor Guardian Control Panel QuikStor Security Software QuikStor Security Software Cl g Reports Non Tenant About User Guide UC Boot Yersiors 1 0 2 ON f CLICK UC Firmware Wersion 1 6 4 DIAGNOSTIC Fort COM3 Bi
45. online and properly communicating with the PC QuikStor Security and Software 23 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 o Yellow a yellow LED indicates that there has been no polling response from the device for 30 60 seconds If no communication continues for over one minute the status LED will turn to red When the device is brought back online it will return to green within 2 3 minutes o Red a red LED indicates that this device is setup in the software but is not communicating with the PC o Blinking Orange a blinking orange LED indicates that the access point is being held open by the software To return the LED to green simply click the Close Access Point button v NOTE a quick reference guide of these colors and their meanings will pop up if you hover you mouse over an LED or device in the list i i QuikStor Guardian Control Panel QuikStor Storage Q Reports Mon Tenant About F Sensor amp Siren Fone Variables Elevator amp Rela rt Diagnostics l Device List Name Unit Date Time Reypad Action i Entrancse Gardner 2D 11702709 08 24 31 am 1 Let Iri a Exit Invalid Code 11 02 09 08 24 30 am 1 Invalid Code Gh Relay Board WwapnelB 1B 11702709 08 24 29 am 2 Let Out fe Bsa wapnelB 1B 117024709 08 24 28 am 1 Let Ir Brandenburg fn 11702709 08 23 27 am 2 Let Out Weinstein 2C 11702709 08 23 26 am Let Iri Weinstein 2C 117 024709 0
46. onnect the UltraConverter USB cable to the PC until the software is installed Doing so could install the incorrect driver and cause communication issues with your keypads Keypads should be powered up You can verify this by pushing buttons on the keypad You should hear beeps from the key presses and see a welcome message on your LCD screen QuikStor Express Data Entry has been completed and can access the full QuikStor Express software if applicable if you are converting from another version of QuikStor software this will not apply to you Verify that the Allcon Integration is turned on You can verify this by going to File Site Setup Change Site Setup clicking on the Additional tab where it will say Allcon see screenshot below If this is not the case contact QuikStor Technical Support for assistance Change Site Setup Facility A legal question This next question about facility operations is a very critical question Please read it very carefully IF you have Printing any questions please callus about what it means BUT any legal questions about this must be referred to your attorney Here is the situation a tenant is several months late and you have sent them legal notices PreLien etc and then they make a partial payment The payment does NOT pay them up fully They are Technical still behind Do you release all the legal notices and go back tothe first leg
47. own for at least a few holidays throughout the year This box will allow you to define those holidays Simply enter in a description like Memorial Day followed by the date When you click on the date field a calendar comes up which easily allows you to select the date you are looking for Click the ADD or DELETE buttons at the bottom of this frame to add or remove holiday closings Keypad Setup this is where you add keypads into your system Click on the ADD button on the bottom of this frame and enter in a new Keypad ID Description and Keypad Type where Keypad Type is an Entrance Access Door Exit or Elevator These can be selected by using the drop down box in this field You can delete a keypad from the system by clicking the DELETE button at the bottom of this frame Keypad Zone here you define Sue _ which keypads belong to which ve 2 fead Dsscipion keypad zone A keypad zone is i ae l one or more keypads that a tenant may access at the facility In this form you would enter the i zone number followed by one keypad device on the first line Each line can have one zone and one device listed For example if you have a two keypad system and you want them both to be part of keypad zone 1 then you would have two lines as shown in the picture la 4 a Hl as QuikStor Security and Software 26 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 gt QuikSto
48. r Guardian Control Panel QuikStor Security Software QuikStor Security Software S o F Qo save dil Reports Non Tenant About User Guide nad Messages Sensor k Siren Zone Variables Elevator amp Relay Diagnostics Tine one Keypad Ea Sareea a Keypad ID Description Keypad Type Sy en ae Lan Entrance Entrance guar mod 2 24 Hours jal i P a F l i Zone ID aooo Description Regular Hours Open Close Be a200 ee Christmas 12 25 2011 Saturday p mm vt Sunday 03 00 17 00 ja Hois N A E gt ee a s go vV Keypad Messages the keypads come from the QuikStor factory with standard industry messages for various events such as letting someone on to the property notification of delinquency etc However you can click on this tab to modify several of these messages to customize them to your own needs QuikStor Security and Software 27 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 h QuikStor Guardian Control Panel QuikStor Security Software QuikStor Security Software O A C oa O i Reports Non Tenant About User Guide Jes Sensor amp Siren Zone Variables Elevator amp Relay Diagnostics Events Welcome EVENTID 2 0 Line 1 ACCESS GRANTED Delinquent Line a Tail Lock NAME J
49. t associated with this unit such as a Door Close Remember that you can see an historical report showing all activity by clicking on the Reports button or by using the reports in QSX Event Date Time displays the last date and time an event occurred with this unit QuikStor Security and Software 30 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 5 3 QuikStor Guardian Control Panel QuikStor Storage 6 Reports Mon Tenant About li ctivil YZone amp Ker ad ij Ke ad Messages t Sien z y Dia nostics siren One SienZone Active Zone Oecupied E es ate a0 se a i 1 Yes Bl 30 30 30 F gt O Sensor Unit Sensor ID Siren Zone Device Type Active Siren Active Log LastEvent EventDate Time a bia n4 064 1 Panic Pendant Tes Yes FE 327115 1 FIR Motion Yez Yez ou 10 29 2009 7 01 49 4M yc Ade 1 Sensor Yes Yes Checkin 10 29 2009 45732 4M Ec zog4 1 Sensor Yes Yes Close 10 7 2009 11 49 19 4M F pa ma be ae m O Add Repeater i E f Import From QE Sj Sensor Status Report Variables this is the tab where you will fine tune and customize the Guardian system to your facility Here is a listing of the variables and what they do in the program o Relays Seconds there are two relays inside the keypad the main gate relay and the intercom relay The intercom rel
50. t was not pre approved in writing by QuikStor management The client will be responsible for all warranty related installation servicing shipping and handling charges The client will be billed for this replacement until the damaged unit is returned to QuikStor If the defective equipment is not returned within 14 days the client understands that they will be billed in full for the replacement parts QuikStor shall have the sole and final determination if a keypad failure is covered under this warranty v List the 1 10 digit serial number of ONE QuikStor Guardian Series keypad that you would like to activate under this warranty agreement This number is printed on a small white sticker located on the top of the circuit boards far right edge Keypad serial _________ _ v For this keypad initial every step that you have personally witnessed to be true This warranty is not in effect if any step has been skipped not initialed or was done incorrectly v The surge board s Earth Ground connection has a securely installed grounding wire of gauge 12 AWG or larger and is connected to a grounding source not more than 6 from the keypad circuit board An approved grounding source is a properly installed grounding rod or the base of the keypad stand Initials v The keypad has the GND drain wire properly connected to the keypad Surge Board but does NOT have the GND wire connected to another keypad or to the UltraConverter Initials What_is
51. ted access codes are delivered to and signed off by senior QuikStor management By signing and dating this page you agree to all the above terms listed herein Facility Name Facility Address Client Printed Name Today s Date Client Signature QuikStor Printed Name Today s Date QuikStor Signature QuikStor Security and Software 42 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 QUIKSTOR S GUARDIAN SERIES SEVEN YEAR KEYPAD WARRANTY Every QuikStor Guardian Series keypad sold in a Polycarbonate housing and verified as operational and properly connected per QuikStor s documentation requirements below will be covered by a SEVEN year warranty including lightning damage Should such a QuikStor keypad ever fail during the activated warranty period a replacement unit of comparable age and condition will be shipped via UPS Ground at QuikStor s expense The client may have the replacement keypad shipped at a faster rate at their expense To activate your new warranty simply complete a separate copy of this page for each keypad you wish to be warranted This warranty becomes void if the warranted keypad or its components are ever attached to equipment or wired in a manner that was not pre approved in writing by QuikStor management The client will be responsible for all warranty related installation servicing shipping and handling charges The client will be billed for this replacement until th
52. the specific relay that will control each external device o Time Zone Schedule select which time zone will be used with this function Please note that this time zone Is not related to the keypad time zone discussed earlier in the manual See below for relay time zone setup QuikStor Security and Software 35 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 o Time Zone Control you can select Active or Inactive depending on whether or not you want the device to be controlled during Specific hours or not o Onsite Control you select Active or Inactive depending on whether or not you want the device to be controlled based on if someone is onsite or not This is useful if you want to have lighting come on only when someone is onsite at night The Relay Time Zone Schedule section allows you to setup relay zone Time one Zone ID Descriptio d Tce Zone lD 1001 Description Lighting Schedule Open Monday 07 00 Tuesday 07 00 wednesday 07 00 Thursday 07 00 Friday ozon Saturday 07 00 Sunday ozo Holiday 07 00 Close 13 00 13 00 13 00 13 00 13 00 1200 1300 1200 fa m 1002 Perimeter Beam Schedule descriptions such as Lighting Schedule In this section you can also select the hours that you want to associate with that schedule See the Elevator amp Relay Setup screenshot on the following pag
53. trol the siren duration at your facility Occupied how many seconds should the alarm sound when there is an unauthorized opening of an occupied unit QuikStor Security and Software 29 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 Vacant how many seconds should the alarm sound when there is an unauthorized opening of a vacant unit Tamper Event how many seconds should the alarm sound when there is a tamper event detected wall removal introduction of a second magnet etc o Sensor Information this table shows a list of the wireless sensors programmed at your facility There are various options that can be setup for each individual sensor Unit the unit associated with the sensor sensor ID this is the hardcoded ID of the sensor This number can be found on a tag inside of the wireless sensor Siren Zone the siren zone that this sensor is associated with Device Type use the drop down box to select the type of wireless device you would like to monitor You may select Sensor Panic Pendant Motion Sensor or Repeater Active Siren will the siren sound if this unit is activated Turning this off individually allows a manager to silence a siren temporarily while conducting an auction cleaning a unit performing maintenance etc Active Log select Yes if you want to log activity for this sensor No if you do not Last Event shows the last type even
54. tware 28 6613 Valjean Avenue Van Nuys CA 91406 Tel 1 800 321 1987 Fax 818 501 5785 gt ADATE Current date in MM DD YYYY format gt DOW Current day of the week 3 letter abbreviation For example FRI for Friday gt ATEMP Current interior temperature of the keypad in Fahrenheit The F symbol will be appended to the value Vv Sensor amp Siren Zone There are two buttons at the bottom of this tab Import from QB this button can be used to import a sensor database file from the legacy QuikStor QB wireless alarm controller Sensor Status Report this report provides the user or QuikStor Support a quick way to identify the status of the wireless sensors specifically to confirm if they have all checked in recently o Siren Zones Wireless Alarm Systems only you can set up siren zones so that only sirens in the affected areas sound For example if you have a unit on the 3 floor you may want to create a siren zone that only sounds the sirens on the 3 floor Active Zone select Yes if you want this zone to actively sound a siren when activated No if you do not Relays enter which relay is triggered when this siren zone is activated If you would like to have multiple sirens on multiple relays sound at the same time just separate them with commas i e 61 62 63 o Siren Settings Wireless Alarm Systems only there are three separate variables that you can set to con