1. ook DESCRIPTIONS Temperature Trend display Low battery icon Humidity Trend Comfort Level display F C switches Channel switches Reset button Battery compartment Wall mount hole Battery compartment lid O ANOARWN gt EN EN GETTING STARTED BATTERIES Batteries for the remote and main units are supplied with this product Replace them whenever the low battery signal displays Remove the battery compartment lid on the bottom of the main unit and insert the batteries Use a small Phillips screwdriver to remove the remote unit compartment lid Be sure to match the correct polarity as shown in the battery compartment Before you close the lid press the RESET button with the point of a blunt object such as a ball point pen NOTE Insert the batteries in the remote unit before you set up the main unit Do not use rechargeable batteries AC POWER ADAPTER An AC power adapter is supplied for use with the main unit You must connect the power adapter if you wish to use the continuous projection or backlight features The jack is located in the battery compartment NOTE t the AC power becomes unavailable the unit will automatically switch to battery power SWITCH BETWEEN MODES Press SELECT The select mode will flash The display will stop flashing if no key is pressed within 5 seconds CHANGE SETTINGS Press and hold SELECT for 2 seconds Then press UP or DOW
2. 20 TROUBLESHOOTING Protiom Symptom Remedy Calendar Shows LLL Temperature is out of or HHH range Strange date Change language month pg 12 Backlight No continuous backlight Plug in AC power adapter Check the BACKLIGHT switch gt pg 8 17 Projector No Plug in AC continuous power backlight or adapter projection pg 8 17 18 21 Problem Symptom Remedy Remote Cannot locate Check batteries unit remote unit pg 8 Check location pg 9 Cannot change channel Cannot auto synchronize Check sensors Only one sensor is working pg 15 Make sure auto synchronization is enabled pg 11 1 Remove batteries 2 Press RESET All memory items will return to default EN EN Problem Symptom Remedy Replace batteries Place clock near window away from electrical devices and wait 10 20 minutes If it still fails you may be too far from a signal Cannot change clock Disable auto synchronization pg 11 Strange reading Set altitude unit pg 14 22 SPECIFICATIONS Main unit dimensions LxWxH 7 1 x 1 77 x 7 3 inches 181 x 45 x 185 3 mm Weight 2 02 lbs 914 grams with battery Remote unit dimensions LxWxH 3x 1 4x 3 1 inches 75 x 35 x 78 3mm Weight 0 3 Ibs 186 grams with battery Temperature Unit F or C Range Main unit 23 F to
3. PS LO2A This innovative time piece provides not only time keeping but also alarm clock indoor and wireless outdoor temperature humidity monitoring weather forecast and projection clock features into one convenient package Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know In this box you will find Main unit Remote sensor Batteries AC DC power adapter PRODUCT OVERVIEW DESCRIPTIONS 1 Snooze Light and Projection Button TOP VIEW 2 Light sensor 3 Projection lens EN EN LCD DISPLAY 1 DESCRIPTIONS Low batteries icon Clock Barometer Weather forecast Moon phase Calendar Temperature and humidity Alarm 00 OQ Or GN cs BACK VIEW RO N ol BUTTON DESCRIPTIONS Focus focus projector Select switch modes change settings Rotation rotate projector Up increase setting activate auto synch Down decrease setting deactivate auto synch Alarm activate deactivate alarm Channel switch remote unit NOOCRONM C EN EN BOTTOM VIEW is mime DESCRIPTIONS Battery compartment Light sensitivity knob Reset button Backlight switch DC power input jack o9 25omc NOT AC power adapter not shown REMOTE UNIT
4. cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 26 DECLARATION OF CONFORMITY The information below is not to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95 Place Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the product Product No PS LO2A Product Name Remote Thermo Hygro Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate is in conformity with Part 15 of the FCC Rules Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong Operation is subject to the following two conditions 1 2 This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation 27 CAUTION The co
5. continuous backlight and projector 2 x UM 4 AAA 1 5V alkaline batteries ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about other Oregon Scientific products such as digital cameras projection clocks health and fitness gear and weather stations The website also includes contact information for our customer service department in case you need to reach us FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation 25 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications EN EN However there is no guarantee that interference will not occur in a particular installation If this equipment does
6. 122 F 5 C to 50 C Remote Unit 4 F to 140 F 20 C to 60 C Resolution 0 2 F 0 1 C Comfort 68 F to 77 F 20 C to 25 C see also Relative humidity Memory Minimum maximum Trend 0 9 F 0 5 C change Relative humidity Range Main amp Remote Unit 25 to 95 Resolution 1 Comfort 40 to 70 see also Temperature Memory Trend Barometer Unit Range Resolution Altitude Display Memory Trend Minimum maximum 3 change mb hPa or inHg 500 to 1050mb 14 77 to 31 01 inHg 1mb 0 03 inHg 328 to 8202 feet 100 to 2500 meters Rainy cloudy partly cloudy sunny 24 hour 1mb change in 1 hour or 3mb change in 6 hours EN EN Remote unit RF frequency Range Transmission Channel No Unit 433 MHz 98 feet 30 meters with no obstructions approximately every 40 seconds 1 2 o0r 3 F or C Radio controlled clock Synchronization Clock display Hour format Calendar Moon phase Alarm Snooze Auto or disabled HH MM SS 12hr AM PM default or 24hr DD MMM weekday selection in 5 languages E D F I S High medium and low tide 7 melody 2 minute crescendo 8 minutes 24 Projector Display Rotation Focusing Projection Power Main unit Remote unit Current time alarm status 180 and image flip Manual 5 second or continuous 4 x UM 3 AA 1 5V alkaline batteries back up AC DC 6V power adapter for normal operation and
7. N to change each setting Press SELECT to switch options REMOTE UNIT SET UP Up to 3 remote units can be used with this product to monitor outdoor temperature and humidity The measurement unit F or C and channel number 1 2 or 3 switches are located in the battery compartment and should be set prior to installation NOTE Additional remote units sold separately If you are using more than one remote unit be sure to select a different channel number for each unit INSTALLATION Mount the remote unit on a flat surface using the recess holes on the back of the unit For best results Before you insert the batteries select the measurement unit and channel number first Place the unit out of direct sunlight and moisture Do not place the remote unit more than 60 90 feet 20 30 meters from the main indoor unit EN EN Position the unit so that it faces the main indoor unit Minimize obstructions such as doors walls and furniture You may need to experiment with various locations to get the best reception This product can automatically synchronize the date and time with the US Atomic Clock When the unit is within 932 miles 1500 km of a RF signal the reception icon will blink 10 RECEPTION Reception takes 2 10 minutes to complete Once complete the icon will stop blinking Strong signal Weak signal No signal NOT For best results place the unit away from metal
8. OTARCK WITH Fl OREGON SCIENTIFIC Full Weather Station with Radio Controlled Clock and Projection Model PS L02A User Manual EN TABLE OF CONTENTS About this guide eene 2 Product overview sssseeeenn nnne 3 Getting started sese 8 Batteries rer ceni ee dE rea aa dun 8 AC power adapter seeeeee 8 Switch between modes sssssees 9 Change settings seese 9 Remote unit setup sssssereserrnureresussennusnrnrnsnenenererenane 9 Clock zie doe ipee reet 10 ACER neaei aeaa aaraa e aaia AEAN 11 Calendar 5 aea a aana ee 12 Moon Phase sipsit temm aiana 12 Barometer 5 inire redet lt Ded exte er ie Eia eda adt 13 Weather forecast ccccccccceeeeeeeeesecneeeeeeeeeeeeeenaeeeeees 14 Temperature amp humidity eeeseeeess 14 Backlight reet tit te teram Deg eg 17 Projector cce erant desse adair e erp E rg 18 Reset system iseni entsaio aieiaa oa ai 19 Safety and care sssssssisssrrssrrssirsrinsrinnrennernnrenneennreen 20 Warnings irinin a aa Aa a aao 20 Troubleshooting eenenm 21 SpeCifICatiOliS eter eer erts 22 About Oregon Scientific eee 25 FCC Statement essen 25 EN EN Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio Controlled Clock and Projection
9. cklight Move it to the OFF position to disable EN EN Move it to the AUTO position to enable continuous backlight controlled by light intensity When activated the backlight will be on whenever the unit perceives that the room is dark The Light Sensitivity knob is located in the battery compartment Rotate to adjust i When activated the continuous backlight will be half as bright as usual To achieve full brightness press SNOOZE LIGHT 18 PROJECTOR This product has a built in projector for viewing time and alarm status at night NOTE The maximum projection range is 2 meters 6 feet The image gets larger the farther you display it PROJECT TIME ALARM STATUS In a darkened room press SNOOZE LIGHT to display the time and alarm status for 5 seconds FLIP IMAGE Press SNOOZE LIGHT again while the projector is on ROTATE IMAGE The ROTATION switch is located on the back of the unit Rotate to adjust FOCUS IMAGE The FOCUS switch is located on the back of the unit Rotate to adjust CONTINUOUS PROJECTION The AC power adapter must be plugged in to use this feature pg 8 Press and hold SNOOZE LIGHT for 2 seconds when the projection is on When activated the time and alarm atatus will project continuously Press and hold SNOOZE LIGHT for 2 seconds again to deactivate The RESET buttons are located in the battery compartments for the main and remote units Press these button
10. hold SELECT for 2 seconds 3 Select altitude 100 meters to 2500 meters in increments of 10 328 to 8202 feet in increments of 32 81 feet and the unit of measurement mb hPa or inHg Press UP or DOWN to change the setting Press SELECT to confirm 14 WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 19 31 mile 30 to 50 km radius with 70 to 75 percent accuracy The weather forecast is always displayed Ep TEMPERATURE AND HUMIDITY With the press of a button you can check the current indoor or outdoor temperature humidity percentage comfort level trend and record measurements Outdoor measurements are collected by the remote unit Temperature is give at the top humidity is below VIEW MIN MAX CURRENT MEASUREMENTS Press SELECT 3 times until the Temperature and Humidity Areas flash Press UP or DOWN to scan the readings CLEAR MIN MAX MEASUREMENTS While viewing Min Max measurements press and hold UP or DOWN for 2 seconds until a beep sounds This clears the previous measurements from the memory SELECT REMOTE UNIT CHANNEL While in the Temperature Humidity Mode press CHANNEL to switch between CH 1 2 or 3 or press and hold CHANNEL for 2 seconds to enter Auto scan mode If only 1 remote unit is in use you will not be able to change channels or Auto scan If you select Auto the channel will change every 3 seconds To deactivate press and hold CHANNEL f
11. ntent of this manual is subject to change without further notice Due to printing limitation the displays shown in this manual may differ from the actual display The contents of this manual may not be reproduced without the permission of the manufacturer 2004 Oregon Scientific All rights reserved EN
12. or 2 seconds again SENSOR SEARCHING If there is no remote unit signal the temperature and humidity measurement will be blank Check the remote unit batteries or press and hold UP and DOWN for 2 seconds to search for the remote unit s EN EN No sensor Sensor found Searching NOTE Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failures between the indoor and outdoor units This is normal and does not affect the general performance of the product Reception will automatically resume once the interference ends 16 COMFORT ZONE The indoor and outdoor comfort zones are shown for the following conditions Relative Humidity Any gt 70 Wet 6 n Any 4096 Dry 68 77 F 40 70 20 25 C 99 NY Comfort TRENDS The trend arrow for the last 30 minutes always displays Indoor and outdoor temperature and humidity trends are shown separately A 0 9 F 3 p Steady Steady SET UNIT While in Temperature Humidity Mode press SELECT for 2 seconds Press UP or DOWN to switch between F and C Press SELECT to confirm BACKLIGHT Press SNOOZE LIGHT to illuminate the backlight for 5 seconds CONTINUOUS BACKLIGHT The AC power adapter must be plugged in to use this feature pg 8 1 The BACKLIGHT switch is located in the battery compartment Move it to the ON position to enable the continuous ba
13. or electrical objects and near a window with a clear view to the sky TO DISABLE OR ENABLE AUTO SYNCHRONIZATION In Clock mode press DOWN for 2 seconds to disable the auto synchronization The unit will not respond to radio signals until you reactivate the synchronization To enable auto reception press UP for 2 seconds SET OR CHANGE THE CLOCK 1 Press SELECT to switch to the Clock Mode The time will flash 2 Press and hold SELECT for 2 seconds to enter the setting mode 3 Select the US time zone Pacific Mountain Central or Eastern 12 24 hour format hour and minute Press UP or DOWN to change the setting Press SELECT to confirm When activated the Melody Alarm starts quietly then gradually becomes louder It shuts off after two minutes The LCD display lights up for the first 8 seconds SET ALARM 1 Press SELECT several times until the Alarm area flashes 2 Press and hold SELECT for 2 seconds to enter the setting mode 3 Select the hour minute X melody 1 7 and volume level Lo or Hi Press UP or DOWN to change the setting Press SELECT to confirm 4 Press SELECT again when you are finished Z W EN SNOOZE Press the SNOOZE LIGHT button the top of the unit to temporarily disable the alarm for 8 minutes The alarm icon will blink while Snooze is activated TO TURN THE ALARM OFF OR ON Press any button to stop the alarm To turn the alarm off completely deactivate it for the next day p
14. ress ALARM CALENDAR SET DATE Clock auto synchronization must be deactivated before you manually set the date pg 11 1 Press SELECT several times until the calendar area flashes 2 Press and hold SELECT for 2 seconds to enter the calendar setting mode 3 Select the year month date and language Press UP or DOWN to change the setting Press SELECT to confirm NOTE The language options are E English F French D German I Italian and S Spanish Press SELECT until the Calendar Area flashes Then press UP or DOWN to change the date and view the corresponding moon phase BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast pg 14 and a trend line showing the direction of barometric change Barometric changes are measured by the main indoor unit BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed Trend Description Pressure change mb hPa 1 hr 6 hr 3 Steady AM Failing 1 3 VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes Then press UP or DOWN to view the last 24 hours history EN EN SET UNIT AND ALTITUDE You can set the unit of measurement mb hPa or inHg and altitude Setting the altitude allows the product to take more accurate barometric measurements 1 Press SELECT 2 times until the Barometer Area flashes 2 Press and
15. s with the tip of a blunt object such as a ball point pen whenever you change the batteries or whenever performance is not behaving as expected e g unable to establish radio frequency link with remote unit or automatic clock etc This will return all settings to default value and you will lose all stored information minimum maximum temperature and humidity etc EN EN SAFETY AND CARE Do not subject the main unit to extreme force Clean the unit with a slightly damp cloth and mild shock or fluctuations in temperature or humidity detergent Avoid dropping the unit or placing it in a e Do not tamper with the internal components location where the AC power adapter will be stepped Do not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this on WARNINGS E Sende This product is designed to give you years of service if E Remove tie Gatos etn product Tora handled properly Observe the following guidelines i al asta ONT display Do not make any changes or modifications to this product Unauthorized changes may void your this product Unauthorized modifications will void the right to use the product warranty NOTE Do not make any unauthorized modifications to e The content of this user manual are subject to change without notice Never immerse the unit in water This can cause Images not drawn to scale electrical shock and damage the unit
Download Pdf Manuals
Related Search
Related Contents
Transcend 1GB MMCmobile In der Welt des Computers - Репозиторий БНТУ LiPoBalancer Operating Instructions, Software V1 Samsung T240(TWQSUV) 用户手册 Maturiste… m`as-tu vu ? Chers maturistes, une AVIS - La-Z-Boy SL-100U 取扱説明書ダウンロード(2.26MB Planifier - INSTALLATION - Introduction Version 3.14 FST-GTK37iP/GTK17iP, RDH Elektro- Seilwinde für Bühnen und Studios Typ ESG C1 Copyright © All rights reserved.