Home

Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont

image

Contents

1. GP250 0 250 x 0 5 Ibs 0 110 x 0 2 kg 3 divisions GP100 0 6 Ibs 0 3 kg GP250 1 5 lbs 0 6 kg Large 1 High Backlit LCD 10 95 W x 12 50 L x 2 20 H Discrete keyboard switch with ZERO ON OFF UNITS TARE and HOLD 120 VAC 60Hz Ac 9V DC adapter with 6 power cord or one 9 volt battery battery not included Up to 8 hours when Auto Power off is enabled CLEANING AND CARE 1 Handle the scale with care Dropping the scale may cause damage to the scale which will not allow the scale to weigh properly This type of damage is considered abuse and violates the product warranty 2 To avoid damage to the scale never drop heavy objects or exceed 400 Ibs or 200 kg of weight on the scale 3 Clean the scale with a slightly damp cloth DO NOT immerse the scale in water or use chemical abrasive cleaning agents 4 Ifthe scale is not being used for a long period of time remove the battery or turn off the scale WARRANTY This product has a 1 year warranty from the date of delivery against defects in material and workmanship This warranty does not apply if the product was subject to misuse neglect damage or abuse Calibration is not covered under warranty 10 TROUBLE SHOOTING Symptom Recommended Action After pressing the WT HOLD Key and placing a weight on the scale the weight will not hold in the display The continues to flash Remove weight from scale and pla
2. sanaa e e aa o After selecting your desired setting and pressing the TARE key to accept A OFF oF BEE an cece Tane weight on the scale 00 00a See Table 2 Press the UNITS key twice to scroll to END 7 Press TARE key once Press the TARE key to exit the setting and return the scale to 0 0 weight I ACPE pr INE c AUDI AO WEIN ai agas ao pi ar irg GAL 8 The display prompt CAL for 2 3 seconds then exit the calibration mode and return to normal weighing mode If the calibration weight is left on the scale a weight will be displayed Table 1 Table 2 Calibration Calibration Span Range Span Range Model Weight Weight LB KG LB KG GP100 50 LBS 20 KG 900 1600 800 1400 GP250 200 LBS 100 KG 3600 6400 4000 7000 UNIT SWITCHING CONFIGURATION The default setting for switching is ON In this menu you can change the scale to weigh in Kilograms KG only Pounds LB only or Units Switching ON The Auto Power Off feature can be changed when needed by the following instructions Function Scale Response With the scale turned on remove all weight from the scale Press and hold the TARE key for 3 secondS 0c eee ee eee TARE SET Unit To Turn OFF units switching and weigh in LBS only Press the TARE key enter into configuration MONG ie4 oeeQr ea dd add ep eeke
3. dada KG Press TARE key 00 20 ee eee ON Press the UNITS key once to scroll to OFF Press TARE key 00 2 0 eee 0 1 Press the TARE key 000 KG Press the UNITS key 5 times END Press the TARE key to exit the setting and return the scale to 0 0 weight TECHNICAL SUPPORT For technical support and more product details please contact us Via Phone 507 238 8702 or 1 800 637 0529 Via Fax 507 238 8271 or 1 800 368 2042 E mail sales salterbrecknell com Website www salterbrecknell com FUNCTION KEYS UNITS KEY The unit is factory configured for the UNITS switching feature to be active The UNITS key allows you to weigh or compare weights in Pounds LB or Kilograms KG The displayed weight being used can be identified by checking to make sure the bullet on the display is pointing to LB or KG See page 7 for detailed instructions on changing the default units of measure or deactivating the UNITS button Press the units key to scroll between LB and KG displayed weight HOLD KEY This key is used when you are unable to view the displayed weight because an item is larger than the weight platter and display Pressing this key will hold the stable weight in the display after the package has been removed To use the Weight Hold feature 1 Remove all items from the scale making sure the sc
4. Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont Minnesota 56031 Toll Free 800 637 0529 Voice 507 238 8702 Fax 507 238 8271 Email sales salterbrecknell com www salterbrecknell com January 2004 Copyright 2001 2004 Salter Brecknell Weighing Products SALTER GRALTER Models GP100 GP250 Electronic General Purpose Bench Scale UNPACKING YOUR SCALE Carefully unpack and inspect the shipping container for evidence of shipping damage If such evidence is discovered stop unpacking and immediately notify the shipper to arrange to have the shipment inspected by an authorized representative All damages must be promptly filed with the shipper 1 Open the box and carefully remove the scale from the shipping carton save the shipping carton for future use Place the scale on a flat level surface free from vibration Remove the AC adapter and user manual from the packaging material INSTALLING THE BATTERY Use 9V ALKALINE BATTERY ONLY No other type provides a suitable power output To fit the battery remove the cover on the underside of the scale and place the battery firmly into the battery holder a Connect the terminals to the battery and refit the cover b MODELS GP100 GP250 TECHNICAL SPECIFICATIONS Construction Capacity Accuracy Display Platter Size Keypad Power Supply Battery Life 22 gauge steel GP100 0 100 x 0 2 Ibs 0 45 x 0 1 kg
5. acing the object on the scale will activate the hold feature Once the item is placed on the scale for 2 5 seconds remove the object and the scale will display the average weight of the item See page 4 for detailed instructions FUNCTION KEYS ZERO ON OFF KEY This key ZERO ON OFF key performs three functions First it applies power to the scale second it returns the scale to zero weight third it will turn off the scale To turn ON power to the scale Remove all items from the scale Press ZERO ON OFF key The display will show perform a display test 8888 then 0 0 To turn OFF the power to the scale Press ZERO ON OFF key for 3 5 seconds To ZERO to the scale Press the ZERO ON OFF key if the scale will not return to zero weight or a negative weight appears on the display Important Note It is recommended to press the ZERO ON OFF key before placing an item on the scale This will help ensure accurate weight readings TARE KEY To use the tare feature 1 Place an empty container on the weighing platform 2 Press the TARE key The scale will display zero weight 3 When an item is placed on the container the scale only displays the weight of the item not the weight of the container and the item 4 To reset the scale for no tare remove the container and its contents from the weighing platform Press the TARE key then to reset the scale to zero weight Th
6. ale is at zero weight 2 Press the HOLD key A bullet will flash indicating Weight Hold is active 3 Place an item on the scale wait two seconds for the weight to become stable 4 When the weight becomes stable the will no longer flash 5 Remove the item from the scale The weight of the item will be held in the display 6 To clear the display press the HOLD key
7. ce the Weight in the center of the scale OR The scale is not in a stable environment that allows the weight hold feature to work Remove the item and place it back onto the scale OR Not enough weight is applied for the weight hold to work minimum weight required is 1 pound ErrE is displayed Software error turn the scale off then on again 8888 is displayed Software error turn the scale off then on again OR Zero key is stuck Gently free ZERO button Unit will not stay on Auto Power Off is activated See page 5 for configuration Backlit display does not work Display is broken lost my power supply and battery cover Contact the factory at 1 800 637 0529 for replacement parts Incorrect Hold Weight Scale was not able to stabilize and determine a hold weight repeat hold OR Hold key is stuck gently free HOLD button From sticking into base off scale OR Item was not placed on the scale quick enough GENERAL FEATURES and FIRST TIME USE INSTRUCTIONS The GP family of bench scales is intended to be used as a general purpose portable bench scale to weigh objects or packages for determining shipping weights and weight verification The GP series is not intended for Legal for Trade applications Salter Brecknell offers other Legal for Trade scales you can visit our web site at www salterbrecknell com The GP series bench scales offers some uni
8. e tare function will work over the full weighing range of the scale but will not extend the overall capacity of the scale TROUBLE SHOOTING Symptom Recommended Action Not weighing correctly OR Inaccurate weight The scale is under zero Press the ON OFF ZERO key OR Damage to the scale has occurred calibrate the scale see page 6 for instructions OR Press the units key the unit is displaying the incorrect unit of measure LB or KG Weight fluctuates Press ON OFF ZERO key to zero the scale before placing an item on the scale OR Ensure scale is placed in a stable level environment free from vibration OR Turn the scale Off then back on Lo is displayed Replace the battery Over is displayed The weight placed on the scale is over the scales capacity Remove the weight from the scale OR The weight placed on the scale plus the Tare weight is over the scales maximum capacity Remove the weight from the scale ErrL is displayed The scale is under zero Press the Zero key OR Damage to the scale has occurred Calibrate the scale see page 6 for instructions AUTO POWER OFF CONFIGURATION SCALE CALIBRATION INSTRUCTIONS Periodically your scale may require calibration to ensure proper weighing The default setting for sleep mode is 120 seconds The sleep mode can be Calibration may be required if the scale has been improperly used by m
9. ishandling configured to 120 240 seconds or OFF via keyboard If there is no activity the scale or dropping the scale You will need an accurate 50 or 200 pound weight to will turn itself off after 120 seconds calibrate the scale If calibration is performed with a weight other than 50 The Auto Power Off feature can be changed when needed by the following OF 200 pounds EMIT Cause your Seale LOW eIg MING CCURSENy instructions IMPORTANT Do not Enter into Calibration Mode without an accurate weight Function Scale Response Scale calibration is accomplished when needed by the following instructions With the scale turned on Function Scale Response remove all weight from the scale Press and hold the TARE key 1 Make sure the scale is turned off for3 secondS 0c eee eee eee TARE SET Unit 2 Remove all weight from the scale Press the UNITS key to scroll to the next selection 005 A OFF 3 Press and hold the ZERO key and press the UNITS key three times CAL Press TARE key to enter into the AUTO POWER OFF configuration menu 420 120 seconds TESS the UNITS once to acueprang enter into calibration mode 1000 4000 Press the TARE key to accept this setting or the UNITS key to scroll between 240 240 seconds or OFF Spiess le TARE KOy ONGe to zero the scale 2 0
10. que features Auto Power Off The unit is factory configured for the unit to shut off after 2 minutes of non use This feature is designed to save the battery and backlit display life If the scale is going to be powered via the AC adapter and you would like to disable the Auto Power Off feature see page 5 for detailed instructions Units This feature is factory configured for the UNITS switching feature to be active The UNITS key allows you to weigh or compare weights in Pounds LB or Kilograms KG When powering the scale on the units of measure default LB or KG will be used depending on your country of origin The displayed weight being used can be identified by checking to make sure the bullet on the display is pointing to LB or KG See page 7 for detailed instructions on changing the default units of measure or deactivating the UNITS button TARE The tare feature is used when you want to weigh items on the scale while using an empty container to hold them in place on the scale Simply place the empty container on the scale press the TARE key the scale will now display 0 0 weight Place your items in the empty container to obtain the actual weight of the items in the container See page 3 for detailed instructions HOLD The Weight HOLD feature is used when you have a object placed on the scale that is to large for you to view the weight on the display Pressing the HOLD button prior to pl

Download Pdf Manuals

image

Related Search

Related Contents

Guida d`uso  Samsung MM-ZB9 Manual de Usuario  La lettre de motivation - Sotteville-lès  MODELO PROJETO (Caderno de Encargos 2013  納咖(珠海)建材  Extron electronic DSC 301 HD Scale User Manual  「高額物品の管理および活用について」 結果報告書  ENER007-UK User Guide 120322  CẢNH BÁO! Không bao giờ được sử dụng cưa  議事録 - 東京都  

Copyright © All rights reserved.
Failed to retrieve file