Home

Hurricane Moving Light Enclosures

image

Contents

1. on this list Two parallel 1 5 8 x 13 16 Unistrut Use standard Unistrut hardware or order any of the mounting kits below Tempest uses and recommends only stainless steel mounting hardware 4900 MC Stainless Steel pipe clamp kit for pipes 1 5 38mm to 2 50mm OD Four required per enclosure 4925 MC Stainless Steel pipe clamp kit for pipes 2 50mm to 2 5 64mm OD Four re quired per enclosure iei 4900 MB Stainless Steel Bolt Kit for attachment to a user supplied mounting plate up to 1 4 6mm thick Tempest Lighting Inc accepts no responsibility whatsoever for damages arising from deficient mounting design or installation by others mn 3 Heavy Duty stainless steel key draw latches with padlock eyes for extra security Pad locks are not included with the Hurricane enclosure and should be supplied locally Base up Base Down Horizontal or vertical subject to any limitations stipulated by lumi naire manufacturer Fiberglass covers standard white enamel Base exterior grade epoxy powder coat black Custom colors available to special order All RAL colors and most Pantone colors can be matched as required Patented Digital Enclosure Control DEC3 System microprocessor controller and dis play controls temperature humidity and dewpoint DEC3 system runs 24 7 for round the clock protection Factory default settings may be used without any adjustment or user may
2. 4 required per enclosure 6 7 170 75 6 1920 15 75 400 15 75 400 22 560 gt f gt 2 i E 67 70 gt es I 39 991 Somes Entries Mounting Struts Weight 86lb 39kg 80 x24 x26 h weight 150lb 1203 x 61 x 66cm 68kg Schedule B Export Code 8536 30 0000 Designed to UL Standard 50 508 CE EN55015 EN61000 3 4 EN61000 3 5 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN60598 1 NEMA Type 3R Enclosure approximately equivalent to IP54 This product is protected by US Patent Number 6 352 358 Tempest Lighting Inc November 2011 In the interest of continuous product improvement q T FE MPEST specifications are subject to change without notice lighting inc 13110 Saticoy Street Unit C North Hollywood CA 91605 USA www tempestlighting com t 1 818 787 8984 f 1 818 982 5582 info tempestlighting com
3. FF When the lamp is off DEC3 2 goes to work When condi tions are within normal bounds DEC 3 pulses the heater at a low level to prevent condensation and gently chang es the enclosure air every 30 seconds or so We call this pulse mode and it is the key to preventing damaging condensation inside your equipment If the temperature rises above the top set limit DEC3 2 runs the fans to cool it down In cold conditions DEC3 2 will run the heater as required to maintain the bottom set temperature Heater Fan Relay Temp DMX l c Lamp lighting inc Y LLI an gt LLI a Use the simple menus to optimize temperature and humidity settings set DMX address view and reset lamp hour counter and more DEC3 2 s user interface uses CapSense technology for a watertight control panel that s easy to use and easy to read LED indicators show the status of all major functions and the display shows DMX address temperature humidity and any error messages you need to know about And if you need to step back from the Hurricane enclosure all of this is available over RDM in your control room or over the internet And while doing all of this DEC3 2 can tell you what s happening over your RDM network a real boon in larger installations Operating Modes Standalone The enclosure operates independently and automatically requiring no user intervention User may a set parameters s
4. Hurricane Movin Hurricane 1000 protects moving mirror scanners up to 2000 Watts from rain snow ice and humidity Tempest s patented control sys tem makes sure your light is never too hot never too cold and never ever allows deadly condensa tion to form 4 a ae TEMPEST g Light Enclosures Tempest s DEC3 2 control system all the security and reliability of Digital Enclosure Control generations 1 and 2 but now featuring DMX control user definable tem perature and humidity settings and a nifty new control panel so you know exactly what s going on inside every enclosure Best of all DEC3 2 is shipping now with optional RDM remote monitoring so you know exactly what s going on without climbing a ladder DEC3 even features a lamp hour counter so you know when to relamp before the lights go out Hurricane enclosures comprise a stylish and corrosion proof fiberglass body mounted on a sturdy aluminum base containing Tempest s pat ented Digital Enclosure Control electronics fans and heating elements Weatherproof air inlet and exhaust cowls allow the passage of large amounts of filtered air to pass over the luminaire when the lamp is on and a tempered glass projection window assures distortion free projection at any mirror angle By monitoring the interior temperature and humidity of the enclosure DEC3 controls humidity and dew point eliminating con
5. densation and corrosion 24 7 When the fixture is running Hurricane s powerful fans exchange the air inside the enclosure every 2 3 seconds ensuring long lamp and equipment life Hurricane has been tested and approved for all 1200W and the new Cyber 2 0 moving head luminaires lighting inc It s Hurricane Season again and the new Hurricanes are here ready for the new generation of high power moving mirror lights and featuring Tempest s revolution ary DEC3 control system Hurricane protects your scan ner anywhere in any weather e UN z al gt LLJ P The DEC3 2 User Control Panel features weatherproof Cmessage display window and six status LEDs All status information is also available over RDM Tempest Lighting Hurricane enclosures have been op erating for over 10 years in deserts through winters and at sea all over the world Now it s your turn Construction For Luminaire Type Mounting Hardware optional Security Orientation Finish Climate Control Cooling Heating Protection Control Wiring Electrical Connections Exterior grade fiberglass powder coated aluminum and stainless steel Tempered glass optically clear wraparound projection window Stainless steel hardware Clay Paky Golden Scan 1 4 High End Cyber 2 0 And similar luminaires These fixtures have been tested and approved with this enclosure call us for fixtures not
6. ly new controller featuring high reliability surface mount electronics extreme heavy duty switching components and a handy waterproof user control panel on the outside of the enclosure DEC3 2 offers commu nication via DMX and RDM or may be used in its entirely automatic standalone operating mode DEC3 2 monitors internal temperature humidity and lamp current at all times and uses this information to control its lamp relay fans and heaters and report back over RDM if desired DEC3 2 works right out of the box if you don t want to play with its default settings you don t need to DEC3 2 s mission is to maintain temperature and humidity inside the enclosure within the Goldilocks band never to hot never too cold and never never allowing deadly condensation to form Condensation is fatal to electronic equipment particularly in polluted areas or saline envi ronments where condensation brings not only rust and short circuits but also a steady buildup of mineral and salt deposits Incidentally this is very hard to control with air conditioning type systems which is why we don t use them DEC3 2 s function depends on whether the fixture pro jector lamp is on or off Lamp ON When the projector fixture is running the heat from the lamp takes care of humidity and DEC3 2 runs the enclosure s fans to change its air every few seconds ensuring minimal temperature rise above out side ambient Lamp O
7. modify tem perature and humidity threshold settings to optimize performance in different climate types and with different equipment All values and status information are available for remote monitoring over RDM for more information please refer to the Hurricane 2 User Manual available at www tem pestlighting com Filtered fresh air cooled using two powerful AC fans Washable air inlet filter may be simply removed for periodic cleaning Proportionally controlled 500 watt heater dries intake air and maintains internal tem perature within bounds in cold climates Heaters pulse when fixture lamp is detected to be off to maintain internal temperatures above dewpoint and prevent condensation Fixture over temperature double pole relay isolates luminaire if temperature exceeds safe operating limit This relay may also be controlled over DMX providing a simple hard reset in the event of fixture malfunction DMX IN terminal on main circuit board Two DMX THRU terminals one for internal fix ture and one to next enclosure Cable by others Connections landed through conduit entry port provided on enclosure base Enclosure hardwired on site 200 240VAC 50 60Hz 5amps max Light Fixture Americas NEMA L6 20 receptacle provided Asia Europe CE17 16amp receptacle provided Digital Enclosure Control DEC3 2 that s Digital Enclosure Control 3rd Genera tion takes enclosure control to the next level DEC3 2 is aan entire
8. uch as tempera ture and humidity thresholds and monitor sensor information and DEC status at the DEC3 2 user interface Standalone is the default DEC3 2 setup mode unless speci fied otherwise DMX All of the Standalone features but the user can override the lamp relay over DMX to force a hard reset of any moving light that loses its mind RDM As above plus the ability to discover and monitor DEC3 2 over RDM DEC is why again and again users around the world have chosen Tempest enclosures to protect their investment in Lighting and projection equipment Tempest Lighting and DEC3 2 A combination that keeps you looking good and saves you money amp TEMPEST lighting inc Ordering Information Dimensions amp Weights Shipping Weights Dims Palletized Carton Approvals Tempest Lighting Inc The following information must be provided with each order Luminaire type model number and lamp power Orientation base down base up or other angle Custom Colors provide RAL or Pantone reference US style NEMA 6 20 receptacle or INternational CEl 7 16amp blue receptacle 1000 IN Hurricane 1000 230VAC CE17 Luminaire Receptacle 1000 US Hurricane 1000 208 240VAC L6 20 Fixture Receptacle 0000 RD RDM Monitoring Functionality 4900 MB Mounting Bolt Kit 1 2 thread 4 required per enclosure 4900 MM Mounting Bolt Kit M12 thread 4 required per enclosure 4900 MC_ Truss Pipe Mounting Clamp Kit

Download Pdf Manuals

image

Related Search

Related Contents

DCG 230-D / DAG 230-D  Entrenador de retinoscopia  What is a DT-Active Frame Grabber Control?    MODE D`EMPLOI - Primo  König & Meyer Twin Head    Ohmega Ω USER'S MANUAL - Allied Associates Geophysical, Ltd.  Æ FICHE D`IDENTIFICATION ULM DE CLASSE 1  

Copyright © All rights reserved.
Failed to retrieve file