1. 2 Once the Dissolved Oxygen concentration is below 35 the collection bottle valve is opened 3 The attached pipette bulb is squeezed and released to obtain a 20 ml sample 4 The collection bottle valve is then closed 5 This can be repeated if more media is needed Yeast Analysis When the bioreactor is filled with media a small sample of media is retained for later use as a spectroscopic blank This media sample is placed in the refrigerator A yeast blank is prepared by filling a cuvette with the original media without yeast When filling cuvettes the liquid level must be high enough about two thirds full for light to pass through it when inserted into the spectrophometer Clean the optical window of the cuvette with Kim wipes Cuvettes must be inserted so that light from the spectrophotometer passes through the sample with the line on the cuvette facing forward Yeast concentration measurements are taken as follows 1 Set the spectrophotometer wave length to 600 nm 2 The spectrophotometer is zeroed by inserting the opaque blank and setting the transmittance to zero by turning the left dial on the front of the spectrophometer 3 The yeast blank is then inserted and the span is set to 100 transmittance using the right dial on the front of the spectrophometer 4 Another cuvette is filled with unfiltered sample from the bioreactor and placed in the spectrophotometer this is done for each sample taken throughout the experiment
2. 5 The transmittance is measured and a calibration curve is used to convert to concentration Note If the transmittance is less than 20 the sample should be diluted with an equal part of the blank media sample and reanalyzed Remember to correct concentration for the dilution factor Glucose Analysis 1 Draw some of the media sample into a 3 ml syringe 2 Place filter on syringe and force clear media into a 10x75 mm test tube filling at least 20 but not more than 50 3 Insert test tube into holder at port 2 on glucose analyzer 4 Press Sample button on glucose analyzer 5 Record glucose concentration which will appear on screen in about 2 minutes 6 Remove test tube and clean for next sample Bioreactor Setup Procedure The bioreactor should be running before you arrive in class These startup directions are intended for the lab TA and to give you a sense of the procedures involved The steps for the setup of the bioreactor are as follows l Carefully remove the bioreactor from the autoclave and remove the mixer shaft cover from the top of the reactor 2 Properly align the reactor on the apparatus add the media and a few drops of anti foam agent 3 Place the top cover on the reactor vessel so that the media collection device is pointed forward and there is open space to insert the DO and pH probes 4 Once the top cover is in place lightly tighten the four cover bolts 5 Attach the two water jacket fittin
3. cover bolts but do not tighten Place mixer shaft cover on reactor vessel and Autoclave
4. the cap still loose Table 1 Reactor Media Ingredients Glucose C6H1206 Yeast Extract Ammonium Sulfate NH4 2SO4 24 g Potassium Phosphate Monobasic KH2PO 4 3 75g Magnesium Sulfate Heptahydrate MgSO 7H2O 1 2g Calcium Chloride Dihydrate CaCl 2H2O 0 18 g Data and Sample collection Note The media and yeast are added to the bioreactor three hours before lab time so that the yeast mass will have grown a good amount before taking the required measurements You should find the start time recorded on the clip board above the bioreactor The Bailey distributed control system is used to record the dissolved oxygen concentration and to control the nitrogen purge After the bioreactor has operated for approximately three hours dissolved oxygen concentrations and samples for yeast and glucose measurement are collected First the oxygen air supply is cut off and nitrogen gas is purged into the reactor head space This will prevent the oxygen from entering the media sample The Dissolved Oxygen concentration is then recorded every ten seconds until it falls just below 35 A media sample is now taken and the airflow is turned back on The Dissolved Oxygen concentration continues to be recorded until it reaches its original steady state value Sampling Media Samples are taken as follows 1 A collection bottle should be attached to the reactor before starting the data collection Dissolved Oxygen concentration
5. used later as a blank After the reactor temperature is steady about one hour later re span the DO meter to 100 Inoculate reactor with 2 5 g of yeast and record the start time Bioreactor Shutdown Procedure The steps for the clean up of the bioreactor are as follows 1 Ds ce 4 5 6 J 8 9 10 11 12 13 14 15 16 17 18 19 Turn the agitator off Turn the temperature control off Turn the pH control off Close the Air sparger valve Turn off the main power Close the cooling water valve Remove the mixer motor from the top of the reactor and place on top of the apparatus Carefully remove the pH probe and place in the KCI solution Carefully remove the Dissolved Oxygen probe and place in the deionized water Remove the temperature and pressure sensors Remove the nitrogen purge and air sparge tubing from their ports Carefully remove the NaOH tubing from its port and position it such that it doesn t drip Warning The NaOH must be handled with caution Remove the water feeds starting with the bottom while placing a beaker to catch the excess water Place the reactor vessel on a cart and take to the wet lab Remove the cover and wash thoroughly with soap and water and rinse with deionized water Place the cover on the table so that it will not roll off Pour the reactor media into the sink and wash thoroughly Rinse the vessel with deionized water Place back on the cart and attach cover Insert
6. Bioreactor User s Manual Revision 06 1 Bioreactor Experimental Procedure The experiment is carried out in a New Brunswick Scientific Bioflo 3000 bioreactor The bioreactor maintains a constant stirring speed 350 RPM a constant temperature 30 Celsius and maintains the pH above 4 Yeast concentration is measured from spectroscopic readings taken using a Spectronic 20 manufactured by Bausch amp Lomb Glucose concentration is measured with a YSI 2700 Select biochemistry analyzer Sterilization is accomplished using a New Brunswick Scientific AC 48 autoclave Please see Figure 1 for a diagram of the bioreactor apparatus Figure 1 Bioreactor Setup 5 Temperature Probe CHa Feed 1 Sodium Hydroxide Nitrogen Purge Condenser Water Out Condenser Water In Air Sparger Pressure Probe Agitator Motor pH Probe i gt Water Jacket Out Water Jacket In DO Probe Media Collection Device Preparation of the Reactor Media Note To begin the experiment the media must be made one or two days prior to starting the experiment This is done to allow time to sterilize the media in the autoclave and allow it to return to room temperature The reactor media used for each experimental run is prepared in the following manner Add the amount of each material according to Table 1 to five liters of deionized water in the provided polypropylene container and shake until well mixed Autoclave the media then place in the refrigerator with
7. gs and the two condenser water fittings in their appropriate positions on the reactor 6 Place the mixer motor and coupling on the mixer shaft aligning the pin on the shaft with the hole on the motor 7 Carefully remove the pH probe from the KC solution and place it into the reactor 8 Carefully remove the dissolved oxygen probe from the deionized water and place it into the reactor 9 Add 10 cc of water into the temperature well and then place the temperature sensor into the well 10 Carefully attach the NaOH feed into the proper port 11 Attach the Nitrogen purge into the proper port 12 Attach the Air sparger into the proper port 13 Attach the bulb onto the media collection device 14 Turn on the cooling water with the valve located by the sink 15 Turn on the power to the apparatus 16 Turn on the air with the valve located on the side of the apparatus The following steps deal with the turning on the controls of the experiment through the use of the electronic screen located on the front of the apparatus 17 18 19 20 21 22 23 24 Turn on the temperature control to prime Turn on the pH control to PID control The set point should be 4 0 Turn on the agitation control to PID control The set point should be 350 rpm After a few minutes turn the temperature control to PID control The set point should be 30 C Leave the control to the dissolved Oxygen off Withdraw a small sample of the media to be