Home
61A00-1
Contents
1. 1 does not blink unless it hears a loud sound It will not trip cause an alarm condition to the tester unless the tester is held next to the sensor To put the 61A00 1 into test mode hold the tester s speaker directly over the sensor and fire the tester When in test mode the LED on the sensor will continually blink for one minute Every time the tester is fired at the sensor the test mode is extended for 1 minute The 61A00 1 will automatically exit test mode approximately 1 minute after the last test fire from the tester Note Every time the 61A00 1 trips causes an alarm condition the sensor goes into test mode for 1 minute Testing the Sensor Holding the tester near the surface of the glass to be protected aim the tester at the 61A00 1 and press the test button If window coverings are present hold the tester behind the closed window covering not recommended for use with heavy or lined drapes When the sensor is tripped in an alarm condition the LED on the 61A00 1 will illuminate solid for about 4 seconds If the LED does not illuminate solid but just continues blinking reposition the sensor Hand Clap Test The 61A00 1 can be checked by at any time while in normal mode by clapping loudly under the sensor The LED will blink two times but the 61A00 1 will not trip This visually verifies that there is power to the unit and the microphone and circuit board are functioning Specifications Housing material Flame retar
2. dant ABS Alarm duration 4 seconds Microphone Omni directional electret Temperature range 14 F to 120 F 10 C to 50 C Dimensions 4 24 W x 3 13 Hx 1 7 D Data Protocol HAI Supervision Timing 60 minutes Battery Lithium 3V Type CR123A Federal Communications Commission FCC Statement This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interferences to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the receiver away from the control c
3. glassbreak detector Document Number 61100 1 61A00 1 Installation Instructions Description The 61A00 1 Wireless Glassbreak Detector is an omni directional acoustic sensor and wireless transmitter that works with the HAI 45A00 1 Wireless Receiver It is used for detecting the sound of breaking glass providing 360 of coverage Features Wall or Ceiling Mount 360 coverage Powered by a3 Volt Lithium battery Low Battery condition signal transmission Test mode for glass break coverage and RF signal F LI a asi PROGRAM MOUNTING avr MOUNTING HOLE 1 HOLE J l P SENSOR LED Figure 1 Model 61A00 1 Glassbreak Detector Installing the Battery The supplied 3 Volt Lithium Battery powers the unit To install or replace the battery e Remove the cover on the 61A00 1 e Ifapplicable remove the old battery e Install a new battery according to polarity Use care when installing the battery and observe the correct polarity when the battery is inserted See Figure 1 Use only Panasonic Lithium CR2 batteries for replacement WARNING Battery may explode if mistreated Do not recharge disassemble or dispose of in fire Operation The 61A00 1 transmits the following event data Supervision A periodic transmission every 60 minutes to indicate detectors presence Alarm Alarm transmission triggered by the sound of breaking gla
4. hickness Plate 3 32 to 1 4 2 4mm to 6 4mm Tempered 1 8 to 1 4 3 2mm to 6 4mm Wired 1 4 6 4mm Laminated 1 8 to 1 4 3 2mm to 6 4mm It is advisable to avoid the following locations Noisy rooms with multiple noise sources e g kitchens garages home theaters small bathrooms etc Small rooms smaller that 10 x 10 hallways and stairwells Mounted in the corner of a room Rooms lined with sound deadening materials Rooms with closed wooden window coverings Humid areas Outdoors The 61A00 1 performs best e At least 4 from noise sources televisions speakers etc e When the sensor is in the direct line of sight of all glass to be protected Mounting the Detector The 61A00 1 can be mounted to a wall or ceiling using the mounting holes see Figure 1 with the supplied hardware There is no front or back up or down orientation of the sensor required Wall Mounting The best location for mounting the sensor is on the opposite wall within the sensors range and within the line of sight of the glass to be protected The ceiling and adjoining side walls are also good locations Ceiling Mounting Mount the 61A00 1 in any type ceiling within the direct line of sight of the glass to be protected A position of 6 10 into the room provides better detection Test Mode To test the 61 A00 1 we recommend the use of a Sentrol 5709C hand held tester In normal mode the LED on the 61A00
5. ommunicator Move the antenna leads away from any wire runs to the control communicator Plug the controller into a different outlet so that it and the receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklets prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the installation instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation
6. ss Battery Low Whenever the battery reaches a preset low level 2 4V Battery Low signal will be sent with the next message i e Supervision Alarm etc Enrolling the 61A00 1 To enroll the 61A00 1 put the 45A00 1 Wireless Receiver in to Setup mode advance to an unused address location and then press and HOLD the program switch located on the 61A00 1 circuit board see Figure 1 for 1 second and then release The 61A00 1 will then send a series of transmissions and enroll the transmitter Refer to the Installation Instructions for the 45A00 1 for additional information Zone Configuration Avoid configuring the 61A00 1 to a 24 hour zone type e g tamper panic etc so that the sensor is armed while the room is in use Instead consider configuring the zone type as night interior or away interior This will help prevent false alarms Note The 61A00 1 may not consistently detect cracks in glass or bullets which break through the glass Glassbreak sensors should always be backed up by interior protection Select Mounting Location Select a mounting location between 3 and 20 from plate tempered laminated and wired glass and between 3 and 12 from armor coated glass The 61A00 1 may be mounted on an opposite wall adjoining wall or on the ceiling Coverage is measured from the 61A00 1 to the point on the glass farthest from the sensor Optimal Glass Size 1 x 2 3m x 6m or larger Optimal Glass t