Home

Biamp

image

Contents

1. 1 biam_25_3860_9 pkn IP Link Device Interface Revision 9 20 2011 Ethernet Communication Sheet This document provides additional assistance with wiring your Extron IP Link enabled product to your device Different components may require a different wiring scheme than those listed below For complete operating instructions refer to the user s manual for the specific Extron IP Link enabled product or the controlled device manufacturer supplied documentation Device Specifications Device Type Audio Processor Manufacturer Biamp Firmware Version 3 401 2 3 4 600 Model s Nexia Minimum Software and Firmware Requirements 1e Link w link GC Version Compiler Firmware 1 4 0 1 15 3 2 0 Version History Driver Version Date Notes 9 9 8 11 Extron Certified Fixed Hook status Tested on AudiaFlex 5 3 23 11 Extron Certified Added Room Combine controllability Reorganized Redial and Flash command per device type standard Remove Scaled Volume Tested on Nexia PM Extron Certified Added Volume control for tag 11 to 15 with channel 1 and 2 Tested 4 12 8 10 on Nexia PM 3 10 15 10 Extron Certified Added Device ID and Level Step Size Tested on Nexia PM Extron Certified Tested on Nexia PM Took out Redial and Speed Instance ID 2 7 6 10 Changed step volume to 5db per step Added discrete volume control for Instance ID Tag 1 to 10 Added discrete mute control for Instance ID Tag 1 to 10 1 10 27 09 Extron Certified Initi
2. 1 to 32 Mute On Off Mute Channel Mute Inst ID Tag 1 to 15 On Off Ch 1 to 2 Phone Input Level U p Phone Level Instance ID 1 to 16 Tag Room Combine Inst ID Tag Up Down 1 to 2 Ch1 to2 Page 3 of 6 Down 1 biam_25_3860_9 pkn IP Link Device Interface Revision 9 20 2011 Ethernet Communication Sheet Transmit Mute On Off Vol Inst ID Tag 1 to 15 Ch 100 to 12 in steps of 0 5 1to2 Vol Inst ID Tag 1 to 15 Ch Up Down 1 to 2 Step Vol Step Size 0 5 1to5 Volume Discrete 100 to 12 in steps of 0 5 Volume Step Up Down 1 These commands will control the selected id in Dial Instance ID Tag therefore it require the selection of this ID Tag prior to the use of these commands 2 These commands will control the selected id in Logic State Instance ID Tag therefore it require the selection of this ID Tag prior to the use of these commands 3 These commands will control the selected id in Mute Instance ID Tag therefore it require the selection of this ID Tag prior to the use of these commands 4 These commands will control the selected id in Volume Instance ID Tag therefore it require the selection of this ID Tag prior to the use of these commands 5 This Step Size select will select the size that the Step volume will increase by By default this is 0 5db Page 4 of 6 1 biam_25_3860_9 pkn IP Link Device Interface Revision 9 20 2011 Ethernet Communication Sheet S
3. 6 TC Transmit Transmit Mute Preset Recall N A N A Preset Button Hook D 1 16 TC Dialer This logic resides in the Dialer block use this command to hang up Volume V 1 16 Level Room Combine RC 1 to 32 Room Combine For example in order to configure Volume to a MLC 226 IP front panel volume knob drag and drop Volume on to the knob itself and configure Volume Instance ID Tag X and Volume Channel X to a separate button Then in the AudiaFlex configuration software drag and drop a Level Control from the Processing Library to the grid then click the Property Sheet tab gt DSP Attributes 1 tab and enter in VX in the instance ID tag text field There are two ways to dial a number e First way Set Hook to Off then press the digit to be dial This method is similar to dial from home phone pick up the handset and dial the number e Second way If Hook is On press the digit to be dial and press the Hook Off button this will send all the digits out This method is similar to make a call from a cell phone you press all the number and then press the send button All instance ID tag and Channel are set to 1 by default Page 2 of 6 1 biam_25_3860_9 pkn IP Link Device Interface Revision 9 20 2011 Ethernet Communication Sheet Control Commands amp States Dial Keypad Dial Keypad Instance ID Tag Hook Redial Logic State Instance ID Tag
4. al version Tested on an AudiaFlex Page 1 of 6 IP Link Device Interface biam_25 3860 9 pokn 7 erases Ethernet Communication Sheet Revision 9 20 2011 Driver Notes Nexia uses an Instance ID number to specify the exact DSP block to be controlled Custom names Instance ID Tags may be assigned to DSP blocks and used in lieu of Instance ID numbers within NTP Nexia Text Protocol command strings Instance ID Tags may be up to 32 characters but may not start with a number If the Instance ID Tag includes spaces it must be double quote delimited Instance ID Tag when used in a command string The Instance ID number and Instance ID Tag can be found by first making sure the Properties attribute of a control block is enabled by right clicking the DSP block and selecting Properties Then hover over the Property Sheet tab on the left and both identifiers are available in the DSP Attributes 1 tab To simplify instance ID tag naming within the driver a capital letter and a number are used as the Instance ID Tag for a variety of control blocks The following AudiaFlex configuration blocks correspond to the following driver commands Tag Corresponding AudiaFlex Control Command Name Letter Tag Range Block Dial Keypad D 1 16 TC Dialer Double Click Logic State L 1 32 Logic State Mute M 1 32 Mute Phone Input Level 1 16 TC Receive Receive Mute Phone Output Level O 1 1
5. tatus Available Connection Status Connected Disconnected Hook On Off Mute On Off Mute Inst ID Tag 1 to 15 On Off Ch 1 to 2 Phone Line Analog VOIP Receive Mute On Off Room Combine Up Down Room Combine Inst ID Tag Up Down 1 to 2 Ch1 to2 Transmit Mute On Off Vol Inst ID Tag 1 to 15 Ch 100 to 12 in steps of 0 5 1to2 Volume Discrete 100 to 12 in steps of 0 5 Page 5 of 6 IP Link Device Interface biam_25 3860 9 pkn 7 eats es Ethernet Communication Sheet Revision 9 20 2011 Network communication When configuring the Ethernet driver be sure device settings match that of the GC configuration Port Type Ethernet Logon Credentials No Supported Default Port 23 Multi Connection Yes Capable Port Changeable No Ethernet Driver Configuration Description Please refer to user manual for settings and changes to the network communication parameters Notes for the Device Page 6 of 6

Download Pdf Manuals

image

Related Search

Biamp biamp tesira biamp tesira software biamp training biamp systems biamp cornerstone biamp discovery tool biamp parle vbc 2500 biamp camera controller biamp canvas biamp x400 biamp tesira firmware biamp firmware biamp software biamp support biamp tesira download biamp audiaflex biamp audio biamp modena hub biamp soundbar biamp cm20dt biamp tesira server biamp revamp4240t biamp pcr3000rmkiii