Home
- Red Lion Controls
Contents
1. arrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls Headquarters 20 Willow Springs Circle Yo
2. bing communications with other devices on the bus SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit INTERFACE TERMINALS CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 OR LATER e DIGITALLY ISOLATED CANOPEN PORT CAPABLE OF COMMUNICATING WITH ANY CANopen DEVICE e POWERED AND CONFIGURED FROM G3 OPERATOR INTERFACE TERMINAL e BUILT IN TERMINATION RESISTOR SELECTABLE THROUGH JUMPER SETTING e INSTALLATION AND CONNECTION HARDWARE INCLUDED WITH CARD CONTENTS OF PACKAGE G3CN Option Card with pluggable connector Cable already attached to G3CN option card Hardware pack consisting of three screws and a connector housing for the pluggable connector This hardware bulletin ORDERING INFORMATION MODEL NO DESCRIPTION PART NUMBER CANopen option card for G3 operator G3CN interfaces wi
3. e G3CN option card or G3 HMI unit CAN Position 4 of the pluggable connector provides the CAN bus line active high This terminal is isolated from the HMI unit V OPTIONAL 24 VDC Position 5 of the pluggable connector is provided for optional 24 VDC connections This position is available only to tie 24 VDC wires together The G3CN card neither provides 24 VDC power nor uses 24 VDC power through this connection The V position is not connected to any circuitry internal to the G3CN option card or G3 HMI unit SOFTWARE UNIT OPERATION LED TROUBLESHOOTING YOUR G3CN OPTION The LED will illuminate green when the G3CN option card establishes CARD communication with other CANopen devices RUN The LED will illuminate red if no communications have been established with other CANopen devices ERROR CRIMSON SOFTWARE Crimson 2 0 software is available as a free download from www redlion net or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the web site and updating your copy is free If for any reason you have trouble operating connecting or simply have questions concerning your new G3CN option card contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net LIMITED WARRANTY The Company w
4. ional information can be found in your G3 hardware bulletin and the Crimson user manual CANopen PORT PROTOCOLS The G3CN option card has one CANopen port This port may be configured for various CANopen protocols Check www redlion net g3 for currently supported protocols G3CN PORT PIN OUTS Figure 3 TERMINATION RESISTOR 124 9 1W NO ves Ce 2 O Ea anga2982 O22 5 i Pro OG OS TERMINATION RESISTOR ISOLATING DC DC CAN GND CAN CAN An onboard termination resistor is selectable through a jumper setting The termination resistor is rated for 124Q at 1W Ifa different termination resistance is desired choose the jumper setting for no termination resistor At this point you will be required to connect your own termination resistor between positions 2 and 4 of the five position connector CAN GND Position of the pluggable connector provides a CAN ground connection This terminal is isolated from the HMI unit CAN Position 2 of the pluggable connector provides the CAN bus line active low This terminal is isolated from the HMI unit SHLD OPTIONAL CAN SHIELD Position 3 of the pluggable connector is provided for optional shield connections This position is available only to tie shield wires together or to earth ground There is no internal connection to earth ground The SHLD position is not connected to any circuitry internal to th
5. ping section Using the three screws provided connect the option card to the rear cover as shown in Figure 1 Figure 1 Connect the cable from the option card to CN11 on the main board of the G3 operator interface as shown in Figure 2 Be sure both ends of the cable are firmly seated into their appropriate connector housings Figure 2 Carefully replace the rear cover by reversing the instructions for removing the rear cover THE OPTION CARD LABEL Place the option card label on your rear cover in the space indicated by the dashed lines and labeled COMMS EXPANSION MODULE POWER SUPPLY REQUIREMENTS NEW AND EXISTING INSTALLATIONS The G3CN option card draws all of its power from the main board of your G3 operator interface The specifications of your G3 operator interface account for the power needs of an option card COMMUNICATING WITH THE GSCN OPTION CARD CONFIGURING A G3CN OPTION CARD The G3CN is configured using Crimson software Crimson is available as a free download from www redlion net g3 or it can be ordered on CD Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the G3CN using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G3CN through the RS232 PGM port USB port Ethernet port or CompactFlash socket on your G3 operator interface Addit
6. re Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No G3CN E Drawing No LP0587 Released 03 14 MODEL G3CN CANopen OPTION CARD FOR G3 OPERATOR Connector side 2 mounting holes 3 plcs Ceo GENERAL DESCRIPTION The G3 proprietary expansion slot provides a high speed parallel architecture that extends the functionality and flexibility of the G3 series HMI This approach allows the G3 series to evolve concurrently with the latest advances in communications and standards without sacrificing performance This high bandwidth channel has significantly greater throughput when compared to the traditional external serial gateway approach The G3CN option card is easily installed by removing the rear cover of your G3 operator interface attaching the card using three screws and connecting a single cable Adding this card gives the operator interface a CANopen communications port It is built with digital isolation to protect the operator interface from the CANopen bus and vice versa It provides the ability to communicate to any high speed CANopen device The G3CN option board has a termination resistor built in and is selectable through a jumper setting A connector housing is provided to function as a strain relief for the wires that terminate into the five position connector The connector is pluggable for easy removal of the G3 operator interface from the CANopen bus without distur
7. rk PA 17406 Tel 1 717 767 6511 Fax 1 717 764 0839 Red Lion Controls Europe Softwareweg 9 NL 3821 BN Amersfoort Tel 31 0 334 723 225 Fax 31 0 334 893 793 Red Lion Controls India 201 B 2nd Floor Park Centra Opp 32 Mile Stone Sector 30 Gurgaon 122002 Haryana India Tel 91 984 487 0503 China Unit 302 XinAn Plaza Building 13 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688 Fax 86 21 6113 3683
8. th isolated high speed communications ports G3CNO0000 SFCRM2 Crimson 2 0 1 SFCRM200 1 Use this part number to purchase Crimson on CD with a printed manual USB cable and RS 232 cable Otherwise download from www redlion net g3 THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A B C D HAZARDOUS LOCATIONS OR NON HAZARDOUS LOCATIONS ONLY WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS COMPONENT MAY IMPAIR SUITABILITY FOR CLASS WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY DIVISION 2 SPECIFICATIONS 1 POWER REQUIREMENTS Power is supplied to the option card from the main board of your G3 operator interface 2 COMMUNICATIONS CANopen Port The CANopen port has format and baud rates that are software programmable up to 1M baud and are digitally isolated This port may be configured for various CANopen protocols Check www redlion net g3 for currently supported protocols Isolation from G3CN Communication ports to G3 operator interface 1000 VDC for 1 minute 3 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 80 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Altitude Up to 2000 meters 4 CERTIFICATIONS AND COMPLIANCES ELECTROMAGNETIC COMPATIBILITY Emissions and Immunit
9. y to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Immunity to Industrial Locations Reference G3 unit for emissions and immunity specifications 5 CONSTRUCTION Installation Category I Pollution Degree 2 6 INSTALLATION REQUIREMENTS Card must be installed inside the rear cover of a G3 operator interface with the hardware provided See Installing the G3CN Option Card for more details INSTALLING THE G3CN OPTION CARD INSTALLATION INSTRUCTIONS Caution The option and main circuit boards contain static sensitive components Before handling the cards discharge static charges from your body by touching a grounded bare metal object Ideally handle the cards at a static controlled clean workstation Also handle the cards by the edges only Dirt oil or other contaminants that may contact the cards can adversely affect circuit operation Warning Depending upon the G3 operator interface high voltage may be present inside the operator interface Be sure to remove all power before removing the rear cover of the operator interface Each G3CN option card comes with a cable for communications and three screws for attaching the option card to the inside of the G3 operator interface s rear cover To install the option card remove all power and I O communications cables from the unit The G3 operator interface literature contains instructions for removing the rear cover Refer to the Battery amp Time Kee
Download Pdf Manuals
Related Search
Related Contents
Lumens` full-featured, desktop visual presenter "取扱説明書" User Manual Fujitsu ESPRIMO Q920 Anleitung - Bronx Standard deutsch 77901 Bedienung AutoTrac™ RowSense™ - stellarsupport global Canon 9350B001 Digital Camera User Manual Copyright © All rights reserved.
Failed to retrieve file