Home

XM02 Horizontal axis - spare parts list

image

Contents

1. and carriage plate must be stable 20 e Commissioning XMO2 V 06 13 Gema Maintenance A DANGER Injuries can occur inside the protective fence due to the movement of the reciprocator In order to enter the inner area the door interlocks must be released by the control unit This release signal may only be activated by technical personnel General information A XM02 WARNING Before maintenance work can be carried out on the horizontal axis it must be ensured that the horizontal axis cannot be turned on by third parties gt The horizontal axis has to be free of load and disconnected from mains The XMO2 horizontal axis was designed to operate with a minimum of maintenance The motor gear box is self lubricating and maintenance free Regular maintenance and inspection of the horizontal axis increases the working reliability and avoids damages repair downtimes etc Maintenance e 21 Gema V 06 13 Maintenance schedule Drive unit 22 e Maintenance NOTE The following maintenance schedule is based on operation of 8 hours per day Time interval Maintenance works weekly Blow off the outside of the horizontal axis with compressed air or clean it with a soft cloth at least once a week monthly Check the drive unit gearbox for oil loss Check the interior of the horizontal axis for deposits of powder dust and if present clean it every 6 months Check the drive belt
2. 2 V 06 13 Gema Packing transport Introduction This chapter describes special precautions that must be taken during internal transport of the product if the customer himself must pack transport and ship the product such as to have renovations or service work carried out by the manufacturer or the product must be shipped for disposal recycling Requirements on personnel carrying out the work All work must be carried out by personnel trained in packing machines Packing material Selection of packing material Suitably stable wood packing material must be used Procedure when packing Transport the unit only in a horizontal position Transport Data concerning goods to be transported The space requirements correspond to the size of the axes of motion plus the packaging Loading transferring the load unloading At least one fork lift must be available XMo2 Packing transport e 27 Gema V 06 13 Fault clearance Troubleshooting A WARNING Faults may be fixed by trained personnel only Error fault Procedures remedy Reciprocator with carriage plate is waggling Check the connecting bolts between reciprocator carriage plate and the carriage for tightness Adjust the counter rollers without clearance by the corresponding screws on the running wheel bearing guide wheel bearing see also the spare parts list WARNING In no case press the counter rollers otherwise they wear quick
3. En Operating instructions and spare parts list XMO2 Horizontal axis SSS Translation of the original operating instructions Gema Gema Documentation XM02 V 06 13 Copyright 2006 Gema Switzerland GmbH All rights reserved This publication is protected by copyright Unauthorized copying is prohibited by law No part of this publication may be reproduced photocopied translated stored on a retrieval system or transmitted in any form or by any means for any purpose neither as a whole nor partially without the express written consent of Gema Switzerland GmbH MagicCompact MagicCylinder MagicPlus MagicControl OptiFlex OptiControl OptiGun OptiSelect OptiStar and SuperCorona are registered trademarks of Gema Switzerland GmbH OptiFlow OptiCenter OptiMove OptiSpeeder OptiFeed OptiSpray OptiSieve OptiAir OptiPlus OptiMaster MultiTronic EquiFlow Precise Charge Control PCC Smart Inline Technology SIT and Digital Valve Control DVC are trademarks of Gema Switzerland GmbH All other product names are trademarks or registered trademarks of their respective holders Reference is made in this manual to different trademarks or registered trademarks Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual We have endeavored to retain the preferred spelling of the trademarks and registered trademarks of the copyright holders To the best of our k
4. ata 9 XMO2 alien a Ts 9 Electrical data cios rial el ige 9 Mechanical data 000 ne ae ae IE aid 9 Electrical connection ooooconnonococccccnnccocconononcnncnnnnnnnn nn Eeee aaup nn O RaR Tan 10 Dimensions een 10 Controller Cabinet 222 222er een Re ren 11 General information 444444ss44442nnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnn nenne 11 Electrical data OO 11 DIMENSIONS 1 2 2 2 22 re a else nee 11 Set up assembly and commissioning 13 Commissioning 15 Assembly of the XMO2 Horizontal axis oooocoonocccccnnoniccconccccccnonanncccnna cnn crono nenn 15 Connecting the XMO2 Horizontal axis to the ZA reciprocator een 15 Preparation for Start up isc titel near tcitintehe 17 General Informatico dende seen 17 Reference pOint Ar iii mnen nn rag 17 Electrical connections cable connections oooccocococococcncnccocononnoncnnnnnnnnnnnanonnnnnno 18 Checkpoints before switching On ooonnnccccnnnoccccnnnocccnnnnonccnn noc cnica non cnn rca 18 Grounding protection type uuersnneeensnnnnnennnnnnnnnnnnnnnennnnnnnnennnnnsnennn nenn nnnn nenn 18 Hoses andi cables u 2 202 nei ib 19 Reference point and mechanical stops rersssssnnnnennnnennnnennennnen nenne 19 Initial Start u tai nn nike 20 Maintenance 21 General information 44 444sss04444nsnnennnonnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnrnnnnn nn 21 XMO2 Table of contents e 1 Gema R Maintenance Ssched l
5. cording to local regulations Before starting up the plant a check must be made that no foreign objects are in the booth or in the ducting input and exhaust air It must be ensured that all components are earthed according to the local regulations before start up General safety regulations e 3 Gema V 06 13 Personnel safety The XMO2 Horizontal axis may only be switched on and operated after careful reading of this manual Incorrect operating of the axis and the corresponding control unit can lead to personal injuries as well as damage to the axis or other parts All moving axes must be secured by the customer before start up and during operation by providing fencing see the local regulations Before start up the grounding of the axis has to be checked Safety devices may not be dismantled bypassed or ignored Open covers hide the danger of injury Safety devices must be held in perfect functioning and may be not put out of operation Maintenance works on the XMO2 Horizontal axis may take place only when the plant is stopped Switch off the plant lock the main switch and remove the key Safety concept The XMO2 Horizontal axis is a constituent part of the system and is thus integrated into the safety system of the plant If it is to be used in a manner outside the scope of the safety concept then corresponding measures must be taken Only original Gema spare parts should be used Any warran
6. e u2 42mm 22 Drive Uit a ne Den ee LEINE 22 Replacing the drive unit 4sersnneneennnnnnnennnnnnnnnnnnnnnnennnnnnn nn nenn 23 Drive belti san el en ein ane cet tears 23 Tensioning the drive belt u 224044444nnnnennnnnennnnnnnennnnnnnnnnn nenn 24 Decommissioning storage 25 Introduction 2 Meran Ha 25 Safetyirules mr ee nie 25 Requirements on personnel carrying out the work 25 Storage Conditions HA ar 26 Type 0fStor ge u m a Han 26 Storage daUo eae 2 2 2 ei 26 Space requirements ooocoocccnccocococoncconcnnnnnnnnononccnnnnnnnnnornnn cnn carr nannan nennen 26 Physical requirements arr rieien eenn K EEA EAA AAEE ERAR 26 Hazard NOLES iii da it 26 ShUt dOWN tii 26 Decommissioning ur Herner herein 26 Clean sio ba 26 Maintenance during Storage ooccccnoccccnnnoccccccnnonccccnno cnn cnn no nc nn nano nn narran rar cnn 26 Maintenance Schedule acria aa anaa EA AE OAE EREET 26 Maintenance WOKS oedran EOAR TE AEAEE caidas 26 Packing transport 27 Introd ction ia dia 27 Requirements on personnel carrying out the work 27 Packing Material An a A et taunt an nennen na ieee eaa TR 27 Selection of packing material oooonnnnonnnconicociconococinnnocannnonanan cnn r nana nc 27 Procedure when packing 4ssrsnneeeennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennn nenn 27 aNs POM EEN 27 Data concerning goods to be transported usersnnneeennnnnnennnnene n
7. en 27 Loading transferring the load UNIOACING c eeeeceeeeteeeeeeeeteeeeeeeaees 27 Fault clearance 29 Troublesho6ting 0 E Aa a 29 Spare parts list 31 Ordering spare Parts ccccececccccececeeeceeeeencaeceeeeecesecaanaeceeeeeseeeaanaeeeeeeeeseeeaees 31 XMO02 Horizontal axis spare parts list cccccececeeeeeeeeeeeeeeeeeeeeseeeeaeeeeeeeeeeeees 32 Controller cabinet spare parts liSt ccccccceceeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeenaees 33 2 e Table of contents XM02 V 06 13 Gema General safety regulations This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the XMO2 These safety regulations must be read and understood before the XMO2 is put into operation Safety symbols pictograms The following warnings with their meanings can be found in the Gema Switzerland operating instructions The general safety precautions must also be followed as well as the regulations in the operating instructions DANGER Danger due to electrically live or moving parts Possible consequences death or serious injury WARNING Improper use of the equipment could damage the machine or cause it to malfunction Possible consequences minor injuries or damage to equipment INFORMATION Useful tips and other information Product specific safety measures XM02 The installation work to be done by the customer must be carried out ac
8. erator for pos 1 268 925 3 R chain duplex 1 2x5 16 mm 870 mm on request 4 Connecting piece duplex 1 2x5 16 mm 221 708H 5 Chain wheel 317 446 6 Clamping set 257 583 7 Rubber buffer 35x40 mm 211 664 8 Polyamide wheel 125 mm 264 776 9 Toothed drive belt wheel 369 748 10 Clamp plate 345 067 11 Toothed belt length 2 X strokes 1480 mm 103 730 12 Guiding roller 15 40x15 9 mm 264 857 13 Pedestal bearing 201 375 Wearing part Please indicate length 7 6 9 XMO2 Horizontal axis spare parts 32 e Spare parts list XMo2 V 06 13 Controller cabinet spare parts list Gema 1 Position regulator CDB X 1003 986 2 Switching power supply 24 VDC 20 W 1007 615 3 Can Hub V3 0 complete 1001 787 4 Peltier cooler 24 VDC 30 W 1005 583 5 Axial flow fan 24 VDC 1007 614 6 Clamping profile SS 386 820 7 Cable bush 2 2 386 847 8 Clamping profile GS 386 839 9 Gasket 386 855 10 Allen cylinder screw M5x30 mm 216 372 XMO02 Horizontal axis controller cabinet XMo2 Spare parts list e 33
9. for wear and tension Check the rollers on the carriage for free movement and wear Check the running surfaces for wear and deposits and if present clean them NOTE The parts which are to be replaced during maintenance work are available as spare parts Please refer to the spare parts list too DANGER During assembly cleaning maintenance and commissioning when close to energized components an electrical shock can cause serious injury or death gt All work must be carried out only by technical personnel and when no power is applied The motor gear box is self lubricating and maintenance free Observe the contamination of the enclosure strong contamination on the outside can increase the operating temperature of the drive unit Therefore clean the drive unit from time to time with a vacuum cleaner etc Check the drive unit gearbox monthly for oil loss If the drive unit gearbox has to be changed for any reason the complete unit has to be replaced XM02 ae Gema Replacing the drive unit WARNING There is the risk of burns if contact is made with electrical components that have become overheated gt All work must be carried out only by technical personnel and when no power is applied If it is necessary to replace a drive unit gearbox the complete motor unit must be dismantled from the horizontal axis Therefore the horizontal axis has to be free of load and disconnected from mains D
10. l e 5 V 06 13 Gema Function description Field of application The XMO2 Horizontal axis is designed exclusively to carry and to move horizontally the Gema reciprocators ZA and YT as well as the powder coating guns Any other use is considered non compliant The manufacturer shall not be liable for damage resulting from such use the user bears sole responsibility for such actions XMO2 Horizontal axis Typical characteristics The XMO2 Horizontal axis is used for the coating of parts with different widths By coating in this way the powder guns must be driven into each corresponding position for every given width The XMO2 Horizontal axis is used in connection with the ZA05 reciprocator and YT04 synchronization axis Special characteristics The XMO2 Horizontal axis is a feeding axis and has the following characteristics Same control as for the ZA reciprocator Freely adjustable speed setting on the axes control unit Minimum space requirement No additional space required for dismantling and service works Low overall height Manually movable when the control unit is switched off Intermediate and larger sizes available in steps of 50 mm For more information about the controlling of the axis see the axes control unit operating manual XM02 Function description e 7 Gema V 06 13 Reasonably foreseeable misuse 8 e Function description Operation in rooms with gases Horizontal axis is not ancho
11. lations The grounding screw is located on the horizontal axis base All electrical installations are implemented in accordance to VDE IP54 protection type regulations 18 e Commissioning XM02 vee Gema Hoses and cables All movable hoses and cables must be laid out in such a way that they are neither subjected to any loads nor can hang on other parts The electric cables of the reciprocators must be protected from mechanical damage Reference point and mechanical stops XM02 A The reference point serves as starting point for the axis control unit for calculating the reversing points as well as the maximum travel distance Each time the reciprocator is switched on the control unit requests that the carriage travels to the reference point zero point The carriage travels to the mechanical stop which means onto the rubber buffer The control unit notes this and gives the distance how far the carriage must travel from this position to decompress the rubber buffer The standard value for the X axis is 30 that means 30 mm away from the mechanical stop For this reason the Axis control unit must be programmed in such a way that the reference point is always 30 mm before the lowest mechanical stop zero point WARNING In order to avoid damages to the booth to the gun holders etc the reference point must be set before the first start up Rubber buffer F ss malt A gt a 5 lt lt XT10 horizo
12. ly Reference point not reached Remove the powder accumulation on the running surfaces Check for a foreign body if present remove it Check the XM02 Horizontal axis for proper running move manually Consider the indications in the axes control unit operating manual XM02 Fault clearance e 29 V 06 13 Gema Spare parts list Ordering spare parts When ordering spare parts for powder coating equipment please indicate the following specifications Type and serial number of your powder coating equipment Order number quantity and description of each spare part Example Type XM02 Serial number 1234 5678 Order no 203 386 1 piece Clamp 18 15 mm When ordering cable or hose material the required length must also be given The spare part numbers of this bulk stock is always marked with an Wearing parts are always marked with a All dimensions of plastic hoses are specified with the external and internal diameter Example 8 6 mm 8 mm outside diameter o d 6 mm inside diameter i d WARNING Only original Gema spare parts should be used because the explosion protection will also be preserved that way The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions XM02 Spare parts list e 31 Gema ie XMO2 Horizontal axis spare parts list 1 Motor drive unit complete 1003 823 2 Pulse gen
13. ly anchor the horizontal axis to the floor if it is not mounted to another axis of motion WARNING The movement of the reciprocator can cause injuries gt gt Erect a protective fence around the reciprocator so that there is no danger of injury during normal operation DANGER A Injuries can occur inside the protective fence due to the movement of the reciprocator In order to enter the inner area the door interlocks must be released by the control unit This release signal may only be activated by technical personnel Except for normal operation all other operating modes must be set up by an authorized technical representative XMO2 Set up assembly and commissioning e 13 V 06 13 Gema Commissioning Assembly of the XMO2 Horizontal axis The axis must be leveled in order to ensure a safe and perfect operation After positioning the XT10 Horizontal axis must be firmly fixed on the floor Connecting the XMO2 Horizontal axis to the ZA reciprocator 1 The cables to be connected are lying loose on the carriage plate of the horizontal axis 2 Both cables must be inserted into the cable duct in the ZA reciprocator 1 3 Loosen the screws on the rear side of the ZA reciprocator and pull out the electrical modules Electrical modules in the ZA reciprocator 4 Break out the required opening in the feedthrough rubber and pull through the cables XMO2 Commissioning e 15 Gema an Cable feed th
14. nowledge and belief the information contained in this publication was correct and valid on the date of publication Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication and reserves the right to revise this publication and make changes to its content without prior notice For the latest information about Gema products visit www gemapowdercoating com For patent information see www gemapowdercoating com patents or www gemapowdercoating us patents Printed in Switzerland Gema Switzerland GmbH M venstrasse 17 9015 St Gallen Switzerland Phone 41 71 313 83 00 Fax 41 71 313 83 83 E Mail info gema eu com V 06 13 Gema Table of contents General safety regulations 3 Safety symbols piCtOYTAMS oooononcccnnnocccccnnonccccononcccnnnannccnnnoncnn canon A Teea aaa 3 Product specific safety measures uunesennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne nenn nn 3 Personnel Satelite eevee 4 Safety concept en decid anal A SA O AEA 4 Proper USO innen a tipa 4 About this manual 5 General information ccccccceeeececcee cece cece ceceneaeceeeeeeesecaeaaeceeeeeeesececcueeeeeeeeeeeeneaea 5 Function description 7 Field of aplica ernennen 7 XAMO2 HorizontalaxiS opi idas 7 Typical characteristics u 4m 2a a 7 Special characteristics ana einer anime 7 Reasonably foreseeable misuse unnsnnnennnnnnnnnnnnnnnnnnnnnnnnnn nenn nn 8 Technical d
15. ntal axis reference point and mechanical stops WARNING In order to avoid damages to the booth or the gun holders the reference point must be checked before the first start up and if necessary reset It must be noted that the axes in reference travel moves up to 30 mm behind the control s zero point WARNING The reference point must be referenced before each start up at each switching on after an interruption of the power supply etc Commissioning e 19 Gema ee Initial start up DANGER A Danger of accident gt Never stand on the horizontal axis or under the carriage of the vertical axis when it is in operation WARNING The power of the horizontal axis is much stronger than that of a human being gt All axes must be secured against admittance during operation see local regulations Before start up the horizontal axis the following points must be noted The frame and the drive carriage of the axis must be grounded The grounding of the frame must be done by the customer Adapt the system parameters in the axes control unit see the axes control unit operating instructions In addition the following checks are necessary before the initial start up Travel distance Check by moving manually as well as in accordance to the axes control operating manual Control unit Check the cable connections correct connections squeezed parts cable lengths cable movement etc Stability Horizontal axis
16. ocator control unit Reference point At every start up after the mains have been interrupted the reference point of the reciprocator must be referred again see Reference point and mechanical stops After the reference point is reached the reciprocator begins to carry out the movements set on the reciprocator control unit Before the horizontal axis is put into operation the travel distance must be set on the axis control unit see therefore the corresponding axis control unit operating manual WARNING Incorrect setting of the travel distance can cause damages to the reciprocator to the booth and or to the applicators Commissioning e 17 Gema P Electrical connections cable connections Electrical module Electrical module CM 30 control XT10 connections O NOTE 1 All internal connections between the XT10 axis and the electrical module are to be made according to the enclosed wiring diagram Checkpoints before switching on Before switching on the following checks should be done Check if the cables and hoses are laid out correctly Check if the guns have a clear run and do not touch the booth slots Check the distance between the work pieces and the guns WARNING Before connecting or switching on the horizontal axis read carefully these operating instructions Grounding protection type All metal parts of the horizontal axis must be grounded according to the local safety regu
17. red firmly to the floor The axis mounted on the horizontal axis is not fixed properly Incorrect programming of the end points and travel distance Operation without the proper training Operating the horizontal axis without the protective fence XM02 V 06 13 Technical data XMO2 XM02 Electrical data Gema XM02 Power supply 230 VAC from control unit Tolerance 10 Power consumption 0 3 kW Frequency 50 60 Hz Protection type IP54 Isolation Class F Control unit CM 30 Temperature range e 7 Ba 50 F 104 F Mechanical data XM02 Speed 0 01 0 6 m s Acceleration 0 1 2 0 m s Position detection with incremental pulse generator Reference point corresponds to the zero point Zero point selectable in both end positions Travel distance min Y axis 600 mm X axis 400 mm Travel distance max on request Technical data e 9 Gema 10 e Technical data V 06 13 Electrical connection XM02 CM30 Control unit Y and Z axis power unit necessary all necessary electrical components are installed in the ZAO5 reciprocator no separate electrical connection to Y axis is CM30 Control unit X axis power unit installed in a controller cabinet Motor mains cable 4x1 5 mm all necessary electrical components are Pulse generator extension 20 m Dimensions distance 750 Total length X axis
18. rive belt WARNING Injuries can arise if fingers hair or articles of clothing get caught between the drive belt and the drive wheel or toothed wheel gt All work must be carried out only by technical personnel The toothed drive belt should be checked regularly because it is exposed to large loads when in operation WARNING The drive belt should be checked for wear and tension every 6 N months Powder deposits should be removed with a vacuum cleaner because this can influence the quiet running and shorten the service life of the drive belt Switch on the horizontal axis and check the drive belt for elongation or wear noisy running strong vibration of the belt when reversing the direction of travel WARNING For safety reasons two people should always carry out the following maintenance work XM02 Maintenance e 23 Gema o Tensioning the drive belt YT04 Horizontal axis Tensioning the drive belt Clamp the drive belt 23 with the clamp block 8 and tighten the screws 6 Tension the drive belt with the tensioning screw 11 so that the drive belt will deflect 2 3 cm Tighten the lock nut 10 24 e Maintenance XM02 V 06 13 Gema Decommissioning storage Introduction XM02 Safety rules Before lifting a reciprocator off of its horizontal axes it must be secured from falling over with a lifting device such as a crane fork lift etc The point of attachment is the eye bolt A at the
19. rough in the ZA reciprocator 5 Connect the cable according to the enclosed wiring diagram 6 Push back the electrical modules and fasten them 16 e Commissioning XM02 vue Gema Preparation for start up XM02 A A WARNING Before connecting or switching on the horizontal axis read carefully these operating instructions gt Before the horizontal axis is put into operation the upper stroke limit must be set on the reciprocator control unit see the user manual of the axis control unit General information WARNING Before start up works are done make certain that nobody can switch on the horizontal axis Switch off and lock the mains switch Before starting up the following checks should be done Check the gun holder and hose holder if they are firmly fitted Mount the gun holder in such a way that they do not hit the bottom of the booth slots on start up and cause damage Lay out the cables and hoses in such a way that even at the highest stroke no strain can arise Make sure that no guns can collide with the work pieces Check the grounding of the guns and hose carriers Check if the upper and the lower reversing point of the Z carriage are set correctly The stroke length of the reciprocator must be in the range of the booth opening collision danger Make sure that the automatic guns cannot collide with the work pieces incorrectly adjusted stroke parameters on the recipr
20. top of the reciprocator ZA reciprocator Top view The horizontal axes should be lifted up using lifting straps Requirements on personnel carrying out the work All work should be carried out only by authorized technical personnel Decommissioning storage e 25 Gema V 06 13 Storage conditions Shut down Type of storage For safety reasons horizontal axes should only be stored in a horizontal position Storage duration If the physical conditions are maintained the unit can be stored indefinitely Space requirements The space requirements correspond to the sizes of the axes of motion The load bearing capacity of the floor should be at least 200 kg m There are no special requirements concerning distance to neighboring equipment Physical requirements Storage must be inside a dry building at a temperature between 5 50 C Hazard notes There is no danger to personnel or the environment if the unit is stored properly Decommissioning Before starting any kind of work the axes of motion must be disconnected from the power supply Unplug the power cable Unplug the ground cable Cleaning The running surfaces of horizontal axis must be thoroughly cleaned Maintenance during storage 26 e Decommissioning storage Maintenance schedule No maintenance schedule is necessary Maintenance works During long term storage periodically perform a visual check for corrosion XM0
21. travel 1 i E I o Ind ii 2 By yb b buy o i e eA do An Seni iia 09 i 2 FE IL A LALA 5 2 E 3 a a nl El 4 p 1 M ray 3 pb X E e x ee Jal od s e wl eel gt 2 gt i N N 3 uw EN g d pul T T gi y N 2 UI dii a moro mm Ff A 5 Pl bY iE to a te 50 Freespace 50 Free space 30 5 _ 150 WARNING Due to accident risk and depending on the placement of the horizontal axis the safety barriers have to be placed in accordance to the local regulations XM02 V 06 13 Gema Controller cabinet General information XMO02 Controller cabinet Temperature range 107 40 C P 9 50 F 104 F unsuitable for zone 22 Approvals Electrical data XMO02 Controller cabinet Nominal input voltage 230 VAC 50 60 Hz Control signal CANopen field bus Protection type IP54 Dimensions XMO02 Controller cabinet Width 400 mm Height 750 mm Depth 260 mm Weight 25 kg XM02 Technical data e 11 one Gema Set up assembly and commissioning WARNING N If a free standing horizontal axis is not anchored firmly to the floor uncontrolled movement of the machine or insufficient stability can cause injuries Firm
22. ty claim for damage caused by the use of foreign parts is void Repairs on the axis may only be done by personnel correspondingly trained by Gema Proper use The XMO2 Horizontal axis is only intended for the defined application range The use outside of this range is considered as not intended use e NOTE 1 For further information see the more detailed Gema safety regulations 4 e General safety regulations XM02 V 06 13 Gema About this manual General information These operating manual contains all important information which you require for the working with the XMO2 It will safely guide you through the start up process and give you references and tips for the optimal use of your new powder coating system Information about the function mode of the individual system components booth gun control unit manual gun or powder injector should be referenced to their corresponding documents DANGER A Working without operating instructions Working without operating instructions or with individual pages from the operating instructions may result in damage to property and personal injury if relevant safety information is not observed Before working with the device organize the required documents and read the section Safety regulations gt Work should only be carried out in accordance with the instructions of the relevant documents gt Always work with the complete original document XM02 About this manua

Download Pdf Manuals

image

Related Search

Related Contents

  Epson EB-436Wi  NDR-EA2104 NDR-EA2208 NDR-EA2416    Manual de Instalação    nº do ramal  Melissa CM0801 User's Manual  Virtual Mix Rack - User Manual.pages    

Copyright © All rights reserved.
Failed to retrieve file