Home

User`s Manual - Wind Turbines

image

Contents

1. lt gt Esc Cancel Manual reset In setting window press Esc to return to browsing window without saving the modified parameters In browsing window the button is used as a manual reset key for load short circuit or over load 4 3 Parameter Browsing 1 When power is on the LCD is under browsing window and displays battery voltage XXX V 2 In browsing window LCD will circularly display the following parameters by pressing 1 button and wf O button Light control off voltage Light control on voltage Load 2 time control Load 2 output control mode A light control on off f s Coy anh a AE te a a wat Load 1 time control off hours Ry amp 1 fee WER il J il Load 1 output control mode A light control on off on 10 C LCD can display three output control modes as follows 1 Light control on light control off Left picture indicates the first load output mode is controlled by sunlight intensity The controller will automatically have output at night automatically stop output at day with this control mode User can adjust the light control on and light control off voltage point via LCD button or communication software 2 Light control on time control off Left picture indicates the first load output mode is controlled by sunlight intensity and time simultaneously The controller will automatically have output at night automatically
2. Control Mode PWM Display Mode Ambient Temperature amp Humidity Range 20 55 C 35 85 RH_ No Condensation Load 2 Output Control Mode Factory Default RS232 RS485 RJ45 GPRS Optional Communication Function Optional Temperature Compensation Function Optional 4AmV C 2V 35 C 80 C Precision 1 C By pass Function Optional Dimensions L x W xH 142x150x82mm Net Weight 1 9kg In order to serve our customers better Our company can adjust parameters configuration according to customer s requirement 14 CE 7 Troubleshooting The boll dashing no charge or Battery 1s over voltage check battery voltage and whether the discharge cables are well connected or not re connect all components Battery is over discharge and empty Please use the battery after it The symbol ashane and no output is fully charged Disconnect the battery and recover it with charger device if the battery is over discharge for a long time Overload Please check the load remove the extra or abnormal The symbol W flashing and no output load press Esc button to recover Short circuit Please check load and wiring remove the The symbol flashing and no output short circuit hazard or damaged load press Esc button to recover LCD wire connection might be loose please open controller case to check The fuse might be burnt due to the battery reverse connection No LCD display please open cont
3. panel exceed battery capacity 2 CE the controller will release residual power Common control mode is to dumpload all the power However the battery is not full actually That all the power was consumed via resistors makes resource tremendously wasteful Even with staging dumpload it can be just divided into five to six stages the effect is still unsatisfied Our company adopts PWM Pulse Width Modulation stepless dumpload mode In another word the controller can dump residual power with division into thousands of stages It can dump residual power while charging battery banks which is benefit to effectively extend battery longevity Voltage Limiting and Current Limiting Charge Mode When battery voltage exceeds the pre set dumpload voltage point the controller will adopt PWM voltage limiting charge mode It dumps the excess energy in order to extend the battery longevity When wind turbine charging current exceeds pre set brake current point the controller will automatically start brake to protect battery e g WWS06 48 N If battery voltage exceeds charge shutoff voltage or wind turbine current exceeds wind turbine brake current the controller will automatically start brake Two DC Outputs Mode Each DC output has various control modes for choice including Constant on Constant off Constant half power light control on light control off light control on time control off light control on time control half power light
4. stop output when the time arrives at the pre set time control off hours with this output control mode The controller will also auto stop output when day comes though the pre set time control off time doesn t arrive 3 Constant on Left picture indicates output control mode is constant on The controller will constantly have output within 24 hours unless the battery is protected by over discharge protection over charge protection or malfunctions occurred 11 CE 4 4 Parameter Setting User can set the first load and second load output control modes and parameters by LCD button operation such as light control on voltage light control off voltage time control off hour value When user needs to modify any specific parameters go to browsing window by pressing MEI or Press Enter and access to corresponding setting window then SET comes out on LCD User can modify parameters or status by pressing t ore PE Press the Enter to save the modified parameters and get back to browsing window Just press Esc and roll back to browsing window if user doesn t need to save the parameters 5 Monitoring Software Optional i Ratso omitarkConirol Centa A Spates View Tesla Bathing Hlp FEEE iett Pomm M e D e W LS kwh kwh Fin Homai 00 Meee EA Gun wW i kwh keh Hini Homai Toime O A E wW kwh Cen Horm E pur Home The monitoring software
5. User s Manual Wind Solar Hybrid Street Light Controller Please Read This User Manual Carefully Prior to Installation and Operation of This Product 1 Product Introduction The wind solar hybrid street light controller is an intelligent apparatus which is specially designed for high end small scale wind solar hybrid system and especially suitable for wind solar hybrid street light system and wind solar hybrid monitoring system It can simultaneously control wind turbine and solar panel to charge battery safely and efficiently With decent appearance easy operation visual LCD display and perfect protection functions the apparatus has high charge efficiency low no load loss The system operation shall be safe stable and reliable With high cost performance and long life span it has already been accepted by most customers The wind solar hybrid street light controller is the most critical part in the off grid street light system whose performance will affect the longevity and stability of the whole system especially the longevity of battery 2 Performance Description Reliability Intelligentized modularized design simple mechanism powerful functions With industrial range superior components and strict production technology the controller can be used in relatively bad working environment and has reliable performance and long life span PWM Stepless Dumpload Mode When the power generated by wind turbine and solar
6. according to following procedures after wind turbine solar panel and external circuit constructions are finished Step 1 Check the package and then check the controller for damage after unpacking Damaged controller is not allowed to be installed in the system Step 2 Connect DC load to DC OUTPUT terminals The first load should be connected to and 1 ofthe DC OUTPUT terminals the second load should be connected to and 2 of the DC OUTPUT terminals Step 3 Connect battery to BATTERY terminals with 6mm copper cables or above Note The controller has anti reverse connection protection function but wrong polarity of battery shall be forbidden Step 4 Connect wind turbine output line to WIND INPUT terminals when the wind turbine is under static status or in low speed running status If the wind turbine is single phase DC output just connect the positive pole line to WIND INPUT terminal 6 CE negative pole line to WIND INPUT terminal Step 5 Connect solar panel positive wire to SOLAR INPUT terminal negative wire to SOLAR INPUT terminal Step 6 If the controller has the remote communication function user can read and set relevant parameters via software Step 7 User can set relevant parameters and load output control modes through LCD buttons Step 8 Check whether all the connections are correct and firm 4 LCD Display Instruction and Button Specifica
7. control off light control on time control half power time control off Users can set three output control modes by LCD buttons constant on light control on light control off 3 CE light control on time control off LCD Display Function LCD screen can display system status and parameters via intuitionistic digital and graphic form Such as battery voltage wind turbine voltage PV voltage wind turbine current PV current wind turbine power PV power load current output control modes time control output shutoff hours light control on off voltage points day or night indication load status battery over voltage under voltage status etc Perfect Protection Functions Battery over charge protection battery over discharge protection battery anti reverse connection protection load short circuit over load protection wind turbine current limiting automatical brake manual brake protection solar anti reverse charge solar anti reverse connection lightning protection etc Note Following optional functions are valid only for controllers which have these functions Optional Remote Communication Function The software can monitor real time system running status which contain all the parameters on the LCD screen Through the software users can not only set and adjust relevant parameters but also can control the wind turbine and load running status and alarm while malfunction happens Optional Low Voltage Charge F
8. es appear concurrently the value is the light control off voltage point When OFF and a certain time values appear concurrently the time indicates hours of the time control off 10 Press the Enter key and Esc key at the same time LCD displays the symbol BRAKE which indicates wind turbine in brake status Wind turbine will stop rotating or running in low speed under brake status Press the Enter key and Esc button at the same time under brake status the symbol BRAEE will 8 CE disappear and brake status is released In normal situation the wind turbine shall be in running status rather than brake status 4 2 Button Specification LCD backlight will be on after pressing any button The backlight will go out to save power if there is no button operation for 10 seconds aye t Up Increase In browsing status press TE to check the previous parameter In setting window press this button to check the next adjustable parameter or increase the value of current parameter g 1 7 gt Down Decrease In browsing window press 1 to check the next parameter In setting window press this button to check the previous adjustable parameter or decrease the value of current parameter lt gt Enter Set Confirm In browsing window press Enter to access setting window In setting window press this button to save parameters and return back to browsing window 9 CE
9. is specially developed for the controllers that we produced the following are the part functions which can be realized via the software more information please refer to our software user manual 12 CE a Remote monitoring and parameters configuration for different controller models b Big database system capacity C The controller can network according to RS482 bus GPRS Ethernet d History data inquiry Function r Output Less Volt E y Over Wolt z2 Day Point E W Hight Point 2 LessVotesel 4 Load Selected Node Save Para Restore Factory r General TE Release Volt z y Pa rin Load 1 Status es Load 2 Status g Cpi 5 always open always open kd Release Curr A English always open Device ID 1 z Time of Half Power Begining H Time of Half Power Begining H Charge Admittance i fa Time of Time Control ClosinglH Time of Time Control Closing H S 1 L eT Start Charge 4 y Street Light Controller Parameters Setting Interface 6 Technical Data Rated Battery Voltage ae T Rated Wind Turbine Rated Wind Turbine Input Power Power 400W Maximum Wind Turbine Input Power 600W Battery Over Discharge Protection Voltage Light Control Off Voltage Factory Default 1 5V Adjustable 3 Modes Selection Load 1 Output Control Mode Factory Default Light Control On and Light Control Off 3 Modes Selection Light Control On and Time Control 5 Hours Off Dumpload
10. roller case to check Battery is empty or virtual connection please check the battery voltage and examine whether the wire connection is firm or not If your phenomenon is out of above descriptions or should you have any problems about these products please contact our after sales service department or sales man to repair or replace 8 Installation Environment A Avoid operating the apparatus under direct sunshine blazing sun and rainy moist acid mist environment etc A Keep the apparatus away from flammable and explosive gas or hazard including flame and spark 15 CE 9 Guarantee and Liability One year warranty is available for our product from the date of delivery If the product is out of watranty or damaged by transportation inappropriate operation human factors force majeure no guarantee 1s made 16 CE
11. tion 4 1 LCD Display Instruction n m m DE om SET BRAKE WIRD PY pe ja a Bigh HM 1 N Wind turbine symbol 2 tx Day symbol 2 Night symbol 3 g battery symbol inner strip graph indicates the battery power status Five inner horizontal strips display indicates the battery is full The symbol shall be flashing when the battery is over discharge flashing will not stop until battery voltage recover The symbol shall be flashing when the battery is over charge flashing will not stop until battery voltage recover 7 CE 4 ie Load symbol indicates the load status and malfunction status S indicates load normal output Q indicates load without output lt The symbol Y flashing indicates over load users must remove extra load click Esc key to recover output 5 Light control and time control symbol 0 It indicates light control on and light control off It indicates light control on and time control off 6 SET symbol indicates setting status 7 00 00 Parameters display symbol Each system parameters are displayed via visual digit and graph 8 1 2 at lower left indicates the first load output and the second load output 9 When ON and a certain voltage value appear concurrently the value is the light control on voltage point When ON and LOAD appear concurrently indicates the output mode is constant on When OFF and certain voltage valu
12. unction Boost module is added in the controller to help wind turbine charge battery banks even in low wind or the wind turbine rotates in low speed User can adjust the 4 C admittance value and start charge voltage via software according to different wind turbine parameters Optional By pass Function When the battery is under voltage the controller will automatically switch to the utility grid to get power for driving load to ensure the continuity of the system Optional Temperature Compensation Function The controller can adjust the dumpload voltage according to different ambient temperature so that the battery charge is in the best efficiency Optional SD card Function With SD card controller store system history data when the controller disconnected with PC Optional Wind Speed Detection Function The controller can detect real time wind speed when it is matched with appointed anemometer User can read the real time wind speed via monitoring software Optional Micro current Charge Function When the wind turbine input voltage reaches to the pre set value the controller will produce the micro current charge for the battery Optional Wind Turbine Rotate Speed Detection Function User can read the real time wind turbine rotate status via monitoring software 3 Installation Flow vine BATTERY WIND INPUT B Connection Diagram of Controller Terminals User should connect and operate all parts