1. For example for channel 1 user sets time span from 12 00 to 24 00 amount 120ml dosing times 12 and these results in the addition of 10 ml every hour from 12 00 The design feature of Delay between adjacent pumps is mainly to prevent chemical 10 KSP F Series Dosing Pump Manual interferences Adding a variety of solutions may cause interference with each other so the system utilizes the time delay after current pump starts before next pump starts The default minimum delay is 4 minutes user can change the delay time according to their requirements The maximum delay minutes available to set is dependant upon the number of channels if you divide 60 by the number of channels you have operating this will determine your maximum delay setting For example with 3 channels max delay is 20 minutes whereas with 15 channels maximum delay is 4 minutes Taking a three channel pump as an example assuming the start time of channel 1 is 8 00 the delay minutes is 4 minutes the start time of channel 2 will be 8 04 assuming the delay minutes of channel 2 is 10 minutes the start time of channel 3 is 8 14 After finishing the settings of one day user needs to set day cycle User can dose in Interval of days or at specific Days of week The default day cycle is activation any 1 day e Ifyou selected Interval of days you have to set Activation any days lf 1 was set the dosing will be daily 2 means every 2 days etc Subsequent you have
2. press Set key to confirm End press Esc key to cancel 2 2 8 Set Language The dosing pump supports English Simplified Chinese and Traditional Chinese at present Step Operation Display Sett ings 1 press Set key to enter Settings menu 1 Manual Dose press Up or Down key to choose 2 Program 2 Option 3 Option Qpt ion 3 press Set key to enter 1 SN 001001 j press Up or Down key to choose 4 Glibration Language Engl i sh 5 press Set key to enter press Up or Down key to choose 6 language press Set key to confirm press End Esc key to cancel 2 3 Option In Settings menu press Up or Down key to select 3 Option to enter Option page See follow figure 17 KSP F Series Dosing Pump Manual Qpt ion 4 Galibration 1 SN 001001 5 Language 2 Date and Time 6 Restore Default 3 Channel 3 1 SN shows the serial number of the dose pump each dosing pump has its own unique serial number Press Up or Down key to select 6 Restore Default and press Set key to resets all settings to defaults Note Restore Default will erase user settings so user should make a note of the dosing settings before using it After restoring default all pumps are set to Auto Dose with 0 times per day All pumps are deactivated until user setting to make it work 3 Maintenance The pumps don t need much maintenance It is recommended to clean the inside of the pumps somet
3. KSP F04A If more than 4 channels are required you will use a combination of a master control unit controlling one or more slave units Note If you want to extend the number of channels please read Section 2 2 7 carefully Connection Channels Combination 7 KSP F03A KSP F04 Group B of KSP FO3A connects to Group B of KSP F04 KSP F04A KSP F04 Group B of KSP F04A connects to Group B of KSP F04 KSP F03A KSP F04 Group B of KSP FO3A connects to Group B of the 1st KSP F04 Group C of KSP F03A connects to Group B of the 2nd KSP F04 KSP F04A KSP F04 Group B of KSP F04A connects to Group B of the 1st KSP F04 Group C of KSP F04A connects to Group B of the 2nd KSP F04 KSP F03A KSP F04 Group B of KSP FO3A connects to Group B of the st KSP F04 Group C of KSP F03A connects to Group B of the 2nd KSP F04 Group D of KSP F03A connects to Group B of the 3rd KSP F04 The above 5 combinations only require 1 power supply i e the master KSP F03A or KSp F04A distributes power to the slave KSP F04 units KSP F Series Dosing Pump Manual e AC DC adapter The supplied AC DC power adapter will support China standard European standard American standard Australia standard and other standards e Pump tube Pump tube is installed in pump head We provide PharMed BPT hose as standard which provides a long continuous working life of up to 2000 hours e Connecting pipe 3mm x 5mm PVC transparent t
4. or Down key to choose 2 Date and Time 2011 05 07 5 press Set key to enter 10 30 00 press Up or Down key to modify year month day hour minute second press 6 End Set key to confirm press Esc key to cancel KSP F Series Dosing Pump Manual 2 2 3 Manual Dose This mode is usually used for manually dosing priming cleaning and emptying pipeline Step Operation Display Sett ings 1 press Set key to enter Settings menu 2 press Set key to enter Manual Dose press Up or Down key to choose pump hold Set key to run release Set key to stop 2 2 4 Auto Dose Auto Dose is used to add small equal volume doses periodically It will automatically calculate the dosing volume required for each dosing period based on the daily total volume and dosing times in specified time span such as from 8 00 to 16 00 max 24 hours maximum 1 dose per hour The design of anti chemical interference allows user to set a delay time which prevents any two channels dosing at the same time The following table shows the relationship between total volume and dosing times per day Actual total volume and dosing times are related to the time span user sets Times Day mL Day Times Day 1 2 2 123 4 12346 4 5 12346 8 6 11 12346 8 12 12 120 1234568 12 24 121 240 2 3 4 6 8 12 24 241 360 3 4 6 8 12 24 361 480 46 8 12 24 481 720 6 8 12 24 721 960 8 12 24 961 1440 12 24 1441 2880 24
5. Contents WARRAN TV a is 1 NOTICE dr n i aads 2 A INTRODUCTION iia ais 3 A A A 3 1 2 UINPACKINC 00030 a oe ee ene A A od bo 3 1 3 INCLUDED ITEMS a a e et la a 4 1 4 COMPONEN TS aa A etait 4 IN US A o 8 2 1 POWER ON eerie A cote a AS AT A A ad 8 2 2 SETTINGS 42 od ort oe oes Oe O A 9 221 SOUP WIZAIE ada 9 2 2 2 Set Date and Time cece cccccccecccecccecececensesnsecnseeneeeuecusenetsnesesessnesenecsseees 9 2 2 3 Mana Dase eae ee ee 10 A ALLOK D OSC aeo Mane a ao aaa aebanen beste cease eee 10 2225 CUSIOMIDOSE a 13 2 2 6 Calibration csi ta Aichi Ee ee eas 15 227 IS OECENA AM li a Sas eae das hese ea dias 16 228 E E E OTAN 17 2 3 OPTION A e e do ta de leo alos 17 3 MAINTENANCE idiota i n 18 APPENDIXES 0 c E dcctaeceeine 19 APPENDIX A TECHNICAL SPECIFICATIONS 0coccoccnccnccnconcconconcnnconconncnnonccnncnncnnanncinncnnnnes 19 APPENDIX B PACKING LIST cooooocccccccccncnnnnnccccncnncncononnonnnnnnnnncnnonnnnannnnecnnononcnnennanecinicines 19 KSP F Series Dosing Pump Manual Warranty We warrant your product against any defect in material and workmanship under normal use In the event a product is found to be defective within the warranty period of one year we will at our option repair or replace the defective product The warranty period starts at the day of purchase For warranty validation a proof of purchase must be furnished The followings are excluded from the warranty Improper use of the device cau
6. alous situation You must stop any operation immediately if the equipment is damaged The equipment may be damaged when the following situations occur 1 There is visual damage 2 The product suddenly does not work 3 The product is located in an inappropriate position 1 1 KSP F Series Dosing Pump Manual 1 Introduction About This dosing pump is mainly used to quantitatively add aquarium additives such as Ca Mg and kH supplements It easily maintains water quality greatly reduces the user workload The followings are main features Individual calibration for each channel ensuring dosing accuracy Fully waterproof panel LCD backlit display key operation real time clock All settings are stored in a non volatile storage and never lost even during power failures Provide 3 or 4 dosing channels and can be easily extended up to 15 channels Use high torque long life and quiet motors with long life pump tube which can work continuously for up to 2000 hours The pump shell uses automotive instrument level high strength self lubricating plastic POM 3 dosing modes auto custom and manual Auto Dose Supports dosing in Interval of days or at specific days of week Allow user to set a time span i e from 8 00 to 16 00 the daily total volume and number of doses max 24 i e 1 dose per hour the pump will then dose equal volume for each time in the specified time span The design of anti chemical interference al
7. de of the pump head have snapped in place Important The dosing pump unit must be protected against splashes of water and high humidity Salt water and or high humidity e g as can occur placing near to a sump can damage the device this will voids any warranty claims 1 4 Components Dosing pump unit 3 models are available KSP F03A and KSP F04A are master units a master unit can be used stand alone or can be connected to one of more slave units max 3 The master unit is able to control up to 15 channels independently KSP F04 is a slave unit which must be controlled by master control unit KSP F Series Dosing Pump Manual KSP FO3A is a 3 channel master unit KSP F03A KSP F04 lt A is a 4 channel master unit KSP F04A KSP F04 is a 4 channel slave unit KSP F04 KSP F04 IS NOT CAPABLE OF INDEPENDANT OPERATION KSP F Series Dosing Pump Manual The master control unit has a backlit LCD screen for display and membrane keys for operation The control panel has four keys from left to right these are Up key Down key Set key and Esc key The key functions are as follow e Up key Navigate the menu upward or increase the number e Down key Navigate the menu downward or decrease the number e Set key Confirmation of an input or a choice e Esc key Back to menu or cancel action with Up Down Set Esc saving If you require no more than 4 channels to dose you can choose from the KSP F03A or the
8. et key to enter 1 SN 001001 4 press Up or Down key to choose 4 Calibration Calibration 5 Language 15 KSP F Series Dosing Pump Manual 5 press Set key to enter press Up or Down key to choose the Cal ibrat ing D 6 pump press Set key to start calibration 15s wait for calibration ends or press Esc to Glibrate Vol 7 stop calibration 0050ml press Up or Down key to modify i e set to volume obtained in measuring cylinder 8 End press Set key to confirm press Esc key to cancel x Note The pump tube will inflate after a period of time and the dosing rate will change so you should periodically check the calibration The supplied tube life is stated as up to 2000 hours of continuous running Please change the tube before it reaches this figure 2 2 7 Set Channel Note This setting is only used for extending channel when connecting to KSP F04 units Set channel will erase user dosing settings so user should make a note of the dosing settings before using it Step Operation Display Sett ings 1 press Set key to enter Settings menu press Up or Down key to choose 2 Program 2 p Option 3 Option Opt ion 3 press Set key to enter 1 SN 001001 2 Date and Time 4 press Up or Down key to choose Channel 16 KSP F Series Dosing Pump Manual 5 press Set key to enter press Up or Down key to modify number 6 of channels
9. he running time is longer than interval i e current running is not finished but next scheduled running starts the system will display the message xth too late or xth too early and you need to decrease current start time or increase next start time Step Operation Display Sett ings 1 press Set key to enter Settings menu 1 Manual Dose press Up or Down key to choose 2 Program 3 press Set key to enter 1 Mode Aut o 13 KSP F Series Dosing Pump Manual press Set key to enter Mode press Up or Auto Dose 4 Down key to choose Custom Dose Custom Dose Custom Dose 5 press Set key to enter press Up or Down key to choose pump 6 press Set key to enter press Set key to enter Times press Up or Times 7 Down key to modify press Set key to PL 12 confirm press Esc key to cancel press Up or Down key to choose 8 Time x Set press Set key to enter press Set key to 1 Vol mb 1000 9 enter Vol ml 2 Start 10 30 press Up or Down key to modify press 10 Set key to confirm press Esc key to cancel press Up or Down key to choose 1 Vol mp 1000 11 Start 2 Start 10 30 press Set key to enter press Up or Down Sart 12 key to modify press Set key to confirm PL 10 30 press Esc key to cancel No Back to step 8 13 All times set over Yes go to step 14 1 Times3 14 press Up or Down key to choose Cycle press Set key to enter
10. imes from dust or other contamination The pump must never be lubricated in any way We have provided Pharmed BPT tube as the standard pump tube and it is suitable for use with most chemicals used with aquariums If you require an application specific liquid please contact us to confirm chemical compatibility 18 KSP F Series Dosing Pump Manual Appendixes Appendix A Technical Specifications Drive DC motor Display 132x32 LCD Key membrane key Accuracy less than 5 Input AC 100 240V 50 60Hz 1 0A max Output DC 12V 1A Power Requirements Power Rating 12W Dimensions 257x155x79 mm Ambient temperature O to50 Humidity Range 10 90 non condensing Minimum volume dosed 0 5ml Appendix B Packing List Master Unit KSP F03A KSP F04A Item Quantity Description Dosing pump unit 1 pcs With 3 4 dosing pumps AC DC adapter 1 pcs CE FCC UL CCC Connecting pipe 3 4 meters PVC transparent tube Kamoer connector 3 4 pcs Connect pump tube and PVC connecting pipe Check valve 3 4 pcs prevent possibility of backflow User manual 1 pcs English Slave Unit KSP F04 Item Quantity Description Slave unit 1 pcs With 4 dosing pumps Connecting pipe 4 meters PVC transparent tube Kamoer connector 4 pcs Connect pump tube and PVC connecting pipe Check valve 4 pcs prevent possibility of backflow 19
11. le 5 Cycle any Ad press Set key to enter press Up or Down Interval of days 13 key to choose cycle mode press Set key Days of week to confirm press Esc key to cancel 14 if choose Interval of days press Up or Activation 1 Down key to modify days press Set key to any 2 days KSP F Series Dosing Pump Manual confirm press Esc key to cancel if choose Days of week press Up or Days of week DAXX Down key to enable or disable press Set key to confirm press Esc key to cancel No go to step 6 15 press Esc key to back all pumps set over Yes end 2 2 5 Custom Dose Custom Dose is used to add small doses or large doses at exact time periods It supports additions at the same time Up to 3 channels The maximum add times for each channel in custom dose is 12 times per day User can freely set the volume and start time of each dosing period individually Cycle setting please refers to cycle setting in Auto Dose see 2 2 6 Custom Dose does not offer the time delay feature of Auto dose so it A is possible that additions can be set to occur at the same time which may lead to chemical interference Notes In the setting of custom dose if the volume set is too small i e the running time of the pump is less than 1 second the system will display the message The xth volume too small and you will need to increase the volume If the setting leads to the result that t
12. lows user to set a delay time which prevents any two channels dosing at the same time Custom Dose Supports dosing in Interval of days or at specific days of week Allow user to specify dosing times max 12 and volume of each dose max 9 999ml and support additions at the same time up to 3 channels Manual Dose Allow user to manually dose 1 2 Unpacking Before unpacking please check for damage by delivery Upon opening the package please check that you have received all parts before using The parts list is shown in Appendix B Packing List Please check whether the product has visible damage If any defects are found when unpacking please contact us immediately KSP F Series Dosing Pump Manual 1 3 Included Items AC DC In Kamoer Connector Power Adapter KSP FO3A Control Unit Out A Placement The pumps are self priming and always should be located ABOVE the container with the liquid which has to be dosed This avoids an emptying of the container in the case of a leakage The tube on the intake side should be short To avoid a backflow the tube must not hang in the aquarium water The intake side and out take side of the pump should not be reversed The pump heads can be turned 180 Press both locking tabs on the side of the pump head at the same time and pull the pump off Turn the pump head around 180 and place it again carefully onto the motor shaft do not use force Check that locking tabs on the si
13. om current time The second line from left to right channel start time and dosing time of the next pump A P1 10 30 00 11 00 105 In order to understand the menus please see menu flowchart below Run Settings Manual Dose Pump Choose gt Run Stop Program Choose Mode Auto Dose Pump Choose gt Time Span gt Amount Delay Times gt Cycle Interval of days Custom Dose Days of week Pump Choose Times Option SN Time x Set Volume Date and Time 3 Start Time Set Channel gt Cycle Interval of days Calibration Pump Choose Days of week Language Calibrating Set calibrate rate Restore D efault Menu Structure KSP F Series Dosing Pump Manual 2 2 Settings 2 2 1 Setup Wizard 1 set date and 2 manual dose 3 auto dose 4 custom dose time 7 setlanguage lt 6 set channel m 9 pump calibration All set operation begins with the run page 2 2 2 Set Date and Time Step Operation Display Sett ings 1 press Set key to enter Settings menu press Up or Down key to choose 2 Program 2 E Option 3 Option Qpt ion 3 press Set key to enter 1 SN 001001 d press Up
14. press Up or Down Imerval of days 15 key to choose cycle mode press Set key 14 KSP F Series Dosing Pump Manual to confirm press Esc key to cancel If choose Interval of days press Up or Act i vat ion Down key to modify days press Set key any 2 days to confirm press Esc key to cancel 16 If choose Days of week press Up or Days of week Down key to enable or disable press Set DAX key to confirm press Esc key to cancel press Esc key to back all pumps set No go to step 6 17 over Yes end 2 2 6 Calibration Calibration is the process of measuring and setting an accurate dosing volume The calibration time is 1 minute You should calibrate the pump before using and periodically check Failure to do this can result in inaccurate dosing The dosing pump has been calibrated in the production process Preparations before calibration Have ready a suitable water container Put the inlet and outlet of the dosing tube into the container Fill the tube with water by Manual Dose see 2 2 3 and then have ready an appropriate measuring cylinder to measure the dosing volume Put the inlet of tube into the water container and put the outlet of tube into the empty measuring cylinder Step Operation Display 1 press Set key to enter Settings menu Sett ings press Up or Down key to choose 2 Program 2 Option 3 Option 3 press S
15. sing malfunction The device is repaired or modified by an unauthorized person Use of non produced material by our company i e pump tube Damage by disaster Improper maintenance causing damage Use of reagent or sample causing corrosion Damage by accident or over load oOo N DOO A ON gt Consumables such as silicone tube and fuse etc To obtain warranty support you may contact our local technical support Our technical support will attempt to diagnose and correct the problem If the problem cannot be rectified our technical support will ask you to return the product You will be asked to furnish proof of purchase to confirm that the product is still under warranty Yongchuang kamoer are registered trademarks of Shanghai Yongchuang Medical Instrument Co Ltd We reserve the right to improve or alter appearance and technical specifications without notice KSP F Series Dosing Pump Manual Notice We have considered user safety in the design process Please read this manual carefully Any improper operation may cause damage or danger 1 Safety A The product belongs to Active Products To avoid danger you should 2 observe the following rules If you find any visible damage please do not switch on Be sure not to add any acid alkali or volatile solvents Be sure not to use in humid environment avoid damage by short circuit Temperature change or mechanical wear may increase the volume error Defect and anom
16. to set in how many days to start e Ifyou selected Days of week the days at which the dosing should be proceeded can be assigned When setting 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday and 7 Sunday When setting if the number is displayed dosing for that day is enabled is an X is set dosing for that day is disabled Step Operation Display Sett ings 1 press Set key to enter Setting menu 1 Manual Dose press Up or Down key to choose 2 Program 3 press Set key to enter 1 Mode Auto 11 KSP F Series Dosing Pump Manual press Set key to enter Mode press Up or 4 Down key to choose Auto Dose 5 press Set key to enter press Up or Down key to choose pump 6 press Set key to enter press Set key to enter TimeSpan press Up or Down key to modify start hour From140 00 7 and end hour press Esc key to cancel PL To 24 00 press Set key to enter Amount press Up Amount 8 or Down key to modify total volume press PL 240mL Esc key to cancel press Set key to enter Times press Up or Down key to modify dosing times press Times 9 Set key to confirm press Esc key to j P1 14 cancel press Up or Down key to choose 4 Delay 4mins 10 Delay 5 Cycle any Ad press Set key to enter press Up or Down 11 key to modify press Set key to confirm press Esc key to cancel press Up or Down key to choose 4 Delay 4mins 12 Cyc
17. ube connected to the input or the output of pump 22 e Kamoer connector Tubing connectors connect the input or output of pump to the PVC connecting pipe See Included items in 1 3 e Check valve One way valve it is used to prevent the possibility of any backflow Please note the direction in installation The correct orientation is with the black face of the check valve closet to the output side of the pump If you reverse the direction the pump will not draw fluid you can check in manual mode if valve is reversed or not We recommend placing the check valve at THE END of the dispense line for each pump this way the pump tube will be kept airtight and prevent any evaporation or growth of bacteria e e Cable for extended channels cable provided with slave unit for connection to acme master unit 2 1 KSP F Series Dosing Pump Manual Power On 2 Use First place the pump on a smooth horizontal surface then plug the jack of the AC DC Adapter into the DC connector of the dosing pump unit 12 VDC polarity Inside KSP F Series Ver2 4 line shows the model and the 2nd line shows the version of product outside and connect the adapter to the main power supply After the pump initializes you will see the startup display See figure on right The 1st After initialization the pump enters the run page See figure as follow The first line from left to right dosing mode Auto or Cust