1. Install Hardware Device Drivers ae A device driver is software program that enables a hardware device to work with an operating system This wizard will complete the installation for this device 0x16PC1952 PCI UARTs device driver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the installation click Next What do you want the wizard to do Search for a suitable driver for my device recommended C Display a list of the known drivers for this device so that can choose a specific driver lt Back Cancel Fig 4 OSS DIVISION In case Windows does not automatically find the driver insert in the PC the CD Rom of one of the following programs Quick SPC Easy Acquisition or Marposs Driver Library Click on the CD ROM drives options then press Next Found New Hardware Wizard Locate Driver Files Where do you want Windows to search for driver files Search for driver files for the following hardware device O 0x16PC1952 PCI UARTs The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify To start the search click Next If you are searching on a floppy disk or CD ROM drive insert the floppy disk or CD before clicking Next Optional search locations Floppy disk drives CD ROM
2. drives Specify a locatiori B Microsoft Windows U pdate Fig 5 As soon as the operating system has found the pci card driver press Next fig 6 Found New Hardware Wizard Driver Files Search Results The wizard has finished searching for driver files for your hardware device Sy The wizard found a driver for the following device 4 O 16PC1952 PCI UARTs Windows found a driver for this device To install the driver Windows found click Next Sj c winnt inf oem2 inf 10 If the Windows Logo testing message pops up saying that the software is not compatible with the operating system Fig 7 press Continue Anyway Hardware Installation The software you are installing for this hardware OX16PCI952 PCI UARTs has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP Installation Fig 7 Press Finish to complete the installation Fig 8 If the operating system requests it restart the computer Found New Hardware Wizard Completing the Found New Hardware Wizard 0 16 9
3. minimize as much as possible the electrical noise and the interference typically affecting the measurement signal The ground connections schemes reported in this paragraph represent the optimal solution in order to have a system fully compatible with the EMC standards according to the following directives 73 23 EEC 2004 108 CE 55022 1998 EMC EN55024 1998 EMC If for a specific application the customer considers such technical solutions not required Marposs is not responsible for any possible inaccurate working condition of the devices e Bench application n 1 The whole DigiCrown system control measurement has been placed on a single bench gauge PC serial link Transducers support frame p e The D equipotential connection between the box modules and the transducers support frame can be done whether a metallic conductive frame is used In the glass gauging applications the transducers support frame is usually not a conductive material and the transducers are typically insulated in this case no ground connection is required 18 Bench application n 2 In case the control system PC is placed on a bench while the transducers and the box modules on another we suggest to set up an equipotential link as shown in the points D E Power supply unit D J Transducers box support frame
4. of the DigiCrown system in their possible configurations This user manual follows up the installation of the DigiCrown pei unit Digi Crown pencil probe Digi Crown MAX 31 UNITS end line connector Digi Crown box Digi Crown 232 USB OPTION 2 RS 232 interf E9066 Line or Commercial PC Digi Crown PSU NET 1 Digi Crown PSC OPTION 1 RS 485 card Digi Crown pci isa EEE EEE BE 2 PCI CARD The DigiCrown pci unit achieves the RS485 Half Duplex serial communication with the rest of the network Each card is equipped with two serial ports for the overall management of 31 31 sensors I O modules Up to 6 cards can be interlinked see paragraph 3 1 for the management of up to 12 networks 372 active units The LEDs next to the serial ports display the operating status of the card chapter 5 2 1 Before starting installation In order to ensure the correct operation of the pci card a PC with the following minimum specifications is needed One free PCI slot e Microsoft Windows operating system Windows 2000 NT XP e 128 MB of RAM e 00 MHz processor One of the following programs which can be ordered separately must be installed in the PC e Quick SPC release 2 2 e Easy Acquisition release 2 2 Driver Library These programs enable the PC to recognize the pci card with the system drivers for the installati
5. serial link A A C Main p e power Bench application n 3 If the DigiCrown system is split on two or more benches we suggest to set up an equipotential link as shown in the points D Power Power supply supply Pc unit box Transducers link m Transducers support frame PALME frame unit link I Main power 19 e Automatic machine application For such applications it is strongly suggested to provide the box units and the transducers support frame with an equipotential link in the automatic machine applications the eddy currents normally flow in the transducer s shield Electrical cabinet Pc In Measuring machine serial link box Ground bar t Ground bar t pe Metallic connection between the modules and the transducers lt 20 8 TECHNICAL SPECIFICATIONS DigiCrown pci code 6355321000 Power supply from PCI bus standard 5 V Power absorption P 1 5 W power towards network Current absorption from 5V l 0 2A current towards network INPUT OUTPUT DigiCrown HW amp protocol compatible RS485 rate prog Baud 9600 or 208333 Operating temperature standard PC Maxim
6. 52 PCI UARTs Windows has finished installing the software for this device To close this wizard click Finish Fig 8 11 4 1 Checking the installation of the pci card To check whether the card has been correctly installed click the right hand key of the mouse on My computer in the Windows desktop Click on System properties and select Hardware the window shown below appears Fig 9 System Properties E General Network Identification Hardware User Profiles Advanced Hardware Wizard The Hardware wizard helps you install uninstall repair fes unplug eject and configure your hardware Device Manager aw The Device Manager lists all the hardware devices installed an your computer Use the Device Manager ta change the properties af any device Driver Signing Device Manager Hardware Profiles co Hardware profiles provide way for you to set up and store ell different hardware configurations Hardware Profiles Fig 9 Cancel Apply 12 When you click on the Device manager or System key the following window appears Fig 10 Expanding the Ports COM amp LPT item the new pair of COMs installed with the pci card are included Windows calls them Communications Port 1 Ez view gt max se YOUR 2xXQ2NYOIMY 9 8 Computer C29
7. Disk drives Display adapters 5 DYD CD ROM drives Floppy disk controllers amp Floppy disk drives Human Interface Devices S45 IDE ATA ATAPI controllers Infrared devices Ej Keyboards oO Mice and other pointing devices mj Monitors H gt Multifunction adapters 8 Network adapters Y Ports COM amp LPT Communications Port COM2 i Communications Port COM3 Communications Port COM4 ECP Printer Port LPT1 aPC Communications Port COMS E F PCI Communications Port COM6 E E E E Fig 10 VOR Card Code Serial Number ea J ail Baud Units Baud Sw Version Group cons 115200 Default 1 Units Baud Sw Version Ipp 5 E gm 115200 deta Ff fz J Save E p po oo Fig 11 The number of COMs assigned by the PC the Device Manager window COM6 etc is the same that must be entered in the MDHQSPC configuration software 13 4 2 Connection of networks to cards The connection of the networks is made by means of an RS 485 serial cable directly to connectors J1 and J2 The cables come in the following lengths 2mt code 6738057016 e 10mt code 6738057023 e 15 code 6738057022 25mt code 6738057017 14 5 LED FOR DISPLAY OF UNIT OPERATING STATUS The type of lig
8. INSTRUCTION MANUAL Digi Crown 1 INTRODUCTION TO DIGICROWN PROBING LINE SYSTEM 4 2 E 6 2 1 BEFORE STARTING 6 3 HARDWARE INSTALLATION iscxksstnnscusunusenaxr ciun ukRuEr Dk kn a aei 7 3 1 SYNCHRONIZATION OF CARDS 8 4 CARD SETUP soricina ia iraran asini i 9 4 1 CHECKING THE INSTALLATION OF THE 12 4 2 CONNECTION OF NETWORKS TO CARDS 14 5 LED FOR DISPLAY OF UNIT OPERATING STATUS 15 9 1 ON ERROR AUTOMATIC 16 oT AUTOMA HC 16 6 CALCULATION OF 17 f GROUND CONNECTION sireci siipimies E 18 8 TECHNICAL SPECIFICATIONS eene 21 9 DECLARATION OF 22 10 ORDERING CODES tasas aaa k arant de kikik d da mana dE itk Kreta a tits 23 1 INTRODUCTION TO DIGICROWN PROBING LINE SYSTEM The DigiCrown is a flexible measuring system from 1 to 372 sensors configured in networks from 1 to 12 that can be connected to a PC via an RS232 USB serial interface or dedicated RS485 interface cards for PCI or ISA bus The diagram below shows the elements
9. hting of the red LED on the pci card panel indicates the operating status of the unit There are the following flashing modes ON ERROR LED is activated only when an error is generated e AUTOMATIC this mode includes both the ON ERROR warning and brief flashes to indicate the status of the card channels par 5 2 15 5 1 ON ERROR AUTOMATIC mode Notes 1 HW ERROR gt general hardware and bootstrap errors 2 COM ERROR gt general serial driver and or protocol error 5 2 AUTOMATIC mode T 4096ms 3840ms Notes 3 OK gt the network is in working order 16 6 CALCULATION OF ABSORPTION To calculate the total absorption of the card and networks from the 5 V of the ISA slot consider Vnetwork 7 5 1 D W K 1 25 efficiency of DC DC converter Inetwork Imodules X Nmodules Pnetwork Vnetwork X Inetwork absorbed P network E g the example shown below is specific for a DigiCrown configuration with a maximum RS 485 cable length of 10 m Nmodules 31 31 62 Imodules 0 04 A Piotal absorbed 18 6 x 1 25 1 5 24 75 W 17 7 GROUND CONNECTION In this chapter are reported different technical solutions in order to make sure the DigiCrown system is properly grounded according to the NET s configuration and to the lay out of the different units The purpose of ground connection is to
10. icipal or general waste Law for national adoption of European directives 2002 95 EC and 2002 96 EC and others The provisions of the law only apply to products identified as WEEE waste electrical and electronic equipment marked with the appropriate symbol and in any case put on the market after 13 August 2005 Once put out of use the WEEE product may contain substances and parts that are harmful to human health and the environment and which must be subject to professional treatment for qu reuse recycling or definitive disposal Deliver the WEEE product to an authorised WEEE treatment centre or 2002 95 CE contact the local organisation responsible or your nearest Marposs service centre for information Illegal 2002 96 CE disposal of a WEEE product is a crime punishable by penalties A complete and updated list of the addresses is available in the Marposs website www marposs com www testar com D4340035GF Edition 02 2006 Specifications subject to changes Copyright 2006 MARPOSS S p A Italy All rights reserved MARPOSS and other names marks relevant to Marposs products mentioned or shown in this document are registered trademarks or Marposs trademarks in the United States and in other countries Any rights of third parties to trademarks or registered trademarks mentioned in this document are acknowledged to the respective holders Marposs has an integrated Company Management system for quality environment and safely cer
11. on of the peripheral device 3 HARDWARE INSTALLATION To install the pei card switch the computer off and remove the frame and the metal cover that protects the slot Insert the card in a free PCI slot 3 1 Synchronization of cards The interlinking of the cards is achieved by means of the OUT IN connectors Fig 1 using the 10 pins flat cable that is supplied Fig 2 This series connection besides extending the configuration of the network to up to 6 pci cards 12 networks ensures the synchronization of the measurement reference frequencies in the various networks An isofrequency system is thus obtained The flat cable must be connected to the OUT connector of a card which becomes the master one and to the IN connector of the next card If further cards are present the OUT connector is connected to the IN connector of the third one and so on OUTPUT INPUT Connector Connector ROT 1 9 zi es Fig 1 Fig 2 4 CARD SETUP The recognition of the card by Windows is performed automatically see Fig 3 Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install a device driver for a hardware device To continue click Next Cancel Fig 3 When you press the Next key the window shown below appears Fig 4 Click on Search for a suitable driver for my device and press Next Found New Hardware Wizard
12. tified by ISO 9001 ISO 14001 OHSAS 18001 and QS9000 T amp E certifications Marposs has been awarded the EAQF 94 Qualification and the Q1 Award 24
13. um network length up to 1 Km according to the network config Number of networks per card Dimensions standard short PCI slot Absorbed power see Chapter 6 gt Power required for management of configuration Should the power supply unit integrated in the PC not be able to supply this power DigiCrown module must be installed 21 9 DECLARATION OF CONFORMITY MARPOSS S p A hereby declares that the devices described in this manual comply to the EMC electromagnetic compatibility requirements in compliance with the following directives 73 23 EEC of 02 19 1973 LOW VOLTAGE directive 2004 108 CE of 01 20 2005 directive The devices have been designed assembled and tested in compliance with the following European standards EN55022 1998 EMC EN55024 1998 EMC 22 10 ORDERING CODES The tables below are a general summary of the ordering codes for all the components of the DigiCrown Probing Line The highlighted parts are the elements described in this manual INTERFACES ACCESSORIES ORDER CODE DESCRIPTION ORDER CODE DESCRIPTION 6355322000 DIGI CROWN ISA EXTENSIONS SW packages ORDER CODE DESCRIPTION ORDER CODE DESCRIPTION CM2Z22MA00 QSPC CM2F22MA02 EASY ACQUISITION CM2A12MA01 MARPOSS DRIVER LIBRARY 99 The product and any part that can be mechanically separated from it must not be disposed of the environment and must not be disposed of as mun

Download Pdf Manuals

image

Related Search

Related Contents

PDFファイル  Festool PAC571810 User's Manual  こちら - DKSH ジャパン  USER GUIDE HERRON LIP-EZE ORALIFE PEPPERMINT LIP  DLP-USB245M User Manual Rev 1.1  Wärmeschublade Warming drawer  Conjunto em Alabastro seu estudo e intervenção  Progress Lighting P3959-81 Installation Guide  Mounting and Operating Instructions EB 5857 EN  Pelco IP110 User's Manual  