Home

TRDS4002-LUXOR-B - RVR Elettronica SpA Documentation Server

image

Contents

1. Automatic Frequency Change this happens when there is a signal with the same PI and of better level than the syntonized one PS PROGRAM SERVICE it s the visualized text on the receiver display which has to be of maximum 8 characters as this is the standard dimension of receivers displays 4 10 Rev 1 0 29 11 11 User Manual ELETTRONICA TRDS4002 LUXOR B The TRDS4002 LUXOR B characteristic is to store up to 8 messages and the time of transmission of each of them Every message can be composed from 1 to 16 words of 8 characters and its possible to select the permanence time on the display of each of the 16 separate words PTY PROGRAM TYPE it s the identification of the Program Type which is on air example News Sport Rock etc Its used to qualify on the receiver the automatical research of the program type desired TP TRAFFIC PROGRAM IDENTIFICATION this service indicates with a signal on the receiver display that the program we re receiving includes traffic news AF ALTERNATIVE FREQUENCIES it s the frequencies list of different transmitters which transmit the same program in the adjacent receiving areas The list is memorized by the receiver and used to reduce the commutation time beetwen the different transmitters of the same program TA TRAFFIC ANNOUNCEMENT IDENTIFICATION it used to indicate to the car driver that the traffic news are on air The receiver could use the signal in one
2. TRDS4002 LUXOR B USER MANUAL FS BROADCAST EQUIPMENT Manufactured by R V R ELETTRONICA S p A Italy ile Name TRDS4002 LUXOR B_ RDS_ING_1 0 indb Version 1 0 Date 29 11 2011 Revision History 29201 1 0 First Version JA Ber a a A TRDS4002 LUXOR B User Manual Version 1 0 Copyright 2011 R V R Elettronica SpA Via del Fonditore 2 2c 40138 Bologna Italia Telephone 39 051 6010506 Fax 39 051 6011104 Email info rvr it Web www rvr it All rights reserved Printed and bound in Italy No part of this manual may be reproduced memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner Declaration of Conformity Hereby R V R Elettronica SpA declares that this FM transmitter is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC CE TRDS4002 LUXOR B Table of Contents 1 Preliminary Instructions 1 2 Warranty 1 3 First Aid 2 SH Electric shock treatment 2 3 2 Treatment of electric burns 2 4 General Description 3 4 1 Unpacking 3 4 2 Features 3 4 3 Frontal Panel Description 6 4 4 Rear Panel Description 6 4 5 Connectors Description T 4 6 Technical Description 8 5 Identification of the Modules 10 oe Upper View 10 User Manual Rev 1 0 29 11
3. 11 I This page was intentionally left blank il Rev 1 0 29 11 11 User Manual ELETTRONICA TRDS4002 LUXOR B IMPORTANT The symbol of lightning inside a triangle placed on the product evidences the operations for which is necessary gave it full attention to avoid risk of electric shocks The symbol of exclamation mark inside a triangle placed on the product informs the user about the presence of instructions inside the manual that accompanies the equipment im portant for the efficacy and the maintenance repairs A 1 Preliminary Instructions e General Warnings This equipment should only be operated installed and maintained by trained or qualified personnel who are familiar with risks involved in working on electric and electronic circuits Trained means personnel who have technical knowledge of equipment operation and who are responsible for their own safety and that of other unqualified personnel placed under their supervision when working on the equipment Qualified means personnel who are trained in and experienced with equipment operation and who are responsible for their own safety and that of other unqualified personnel placed under their supervision when working on the equipment A WARNING Residual voltage may be present inside the equipment even when the ON OFF switch is set to Off Before servicing the equipment disconnect the power cord or switch off the mai
4. COM1 serial port 6 REMOTE DB25 8 inp 8 out connector OPTIONAL 7 RS232 COM2 serial port 8 OUT 2 BNC connector for RDS analogic output 9 OUT1 BNC connector for RDS analogic output 10 MPX MPX analogic input connector BNC type 11 PILOTE PILITONE TONE analogic input connector BNC type 6 10 Rev 1 0 29 11 11 User Manual RaWa Ra ELETTRONICA 4 5 Connectors Description 4 5 1 RS232 Type Female DB9 NC TX D RX D NC GND 12V NC CTS NC OONDOAARWDNDM LE NOTE Normally the TRDS4002 LUXOR B is configured as DCE Data Communication Equipment for serial communications 4 5 2 ETHERNET Type Female RJ45 TAS TX RX NC NC RX NC NC CONDOR WN User Manual Technical Description 115 230 VAC 10 Phisical Dimensions W x H x D 483 x 44 x 280 mm 3 5 kg Environmental working temperature 10 to 40 C BNC unbalanced Pilot frequency synch 19KHz 2Hz Input level 30 12dBu Sinusoid o TTL BNC unbalanced 10 Kohm Input level Gain OdB Out MPX Maximum input level 20dBu BNC unbalanced 50 ohm 12dBu to 12dBu step 0 1dB Adj Sw Atut AGNE GainOdB inp MPX Maximum Output level 20dBu Cenelec 50067 Specification UECP SPB490 Ver 6 1 2003 DI PI M S TP TA TP TPY RT CT AF PIN EON PSN TMC TDC EWS IH RDS Groups OA 1A 2A 3A 5A 6A 8A 9A 14A Subcarrier frequency 57 KHz 41 5 Hz Bandwidth 2 4KH
5. instructions and applicable regulations may cause interference with radio communications A WARNING This equipment is fitted with earth connections both in the power cord and for the chassis Make sure both are properly connected Operation of this equipment in a residential area may cause radio interference in which case the user may be required to take adequate measures The specifications and data contained herein are provided for information only and are subject to changes without prior notice R V R Elettronica S p A disclaims all warranties express or implied While R V R Elettronica S p A attempts to provide accurate information it cannot accept responsibility or liability for any errors or inaccuracies in this manual including the products and the software described herein R V R Elettronica S p A reserves the right to make changes to equipment design and or specifications and to this manual at any time without prior notice e Notice concerning product intended purpose and use limitations This product is a radio transmitter suitable for frequency modulation audio radio broadcasting Its operating frequencies are not harmonised in designated user countries Before operating this equipment user must obtain a licence to use radio spectrum from the competent authority in the designated user country Operating frequency transmitter power and other characteristics of the transmission system are subject to restrictio
6. of the following modes a To switch automatically from the Tape or from the Compact Disk to the radio b To automatically switch on the radio when the traffic news begin c To automatically change over from a station which doesn t transmit traffic news M S MUSIC SPEECH SWITCH it s used to modify the music and the spoken volume one by one PIN PROGRAM ITEM NUMBER it s used to plan the receiver to receive certain programs at preselected date and hour RT RADIOTEXT it s used to transmit the text trasmission this function is mainly for the domestic application house receivers EON ENHANCED OTHER NETWORKS it s used to transmit the PI PS AF PTY to the PIN of other radios TDC TRANSPARENT DATA CHANNEL it s used for the data transmission and it could be free used for example to send messages on a brighitly sign IH IN HOUSE APPLICATION it s used to transmit data of exclusive use of the broadcaster and it can be utilized for example to send telemetry data software etc User Manual Rev 1 0 29 11 11 9 10 4 3 Frontal Panel Description RDS ENCODER 1 LED LED indicator of equipment s working status 2 RS232 COM3 Serial port 4 4 Rear Panel Description 1 2 ON OFF Power Switch NETWORK SOCKET FUSE Power supply socket 110 230V 50 60Hz and fuse block 3 GROUND Ground clamp 4 ETHERNET RJ45 socket for ethernet connection OPTIONAL 5 RS232
7. reserved All other trademarks trade names or logos used are property of their respective owners
8. V R Dealer e Accessories spare parts and cables Features ll TRDS4002 LUXOR B is fully digital it use only high quality components like A D and D A 24 bit converters and numerical processing DSP at 32 bit The input section includes analogical BNC The RDS coder manages n 6 data set and dynamic services TMC TDC IH and EWS All functioning and programming parameters are managed through dedicated software The equipment firmware can be updated through serial port without the need of hardware settings and without interruption of the service Two major features of TRDS4002 LUXOR B are compact design and user friendliness Design is based on a modular concept the different functions are performed by modules that for the most part are connected through male and facilitates maintenance and module replacement The input output analog section offers good qualities Descrizione Sistema RDS The RADIO DATA SYSTEM is proper for the transmission of information in mono stereo programs of VHF MF 87 5 108 Mhz User Manual Rev 1 0 29 11 11 3 10 ELETTRONICA It satisfies the requested requirements to the transmission of supplementary data on radio programs 1 Compatibility with the current mono stereo transmissions 2 Absence of interferences towards the adjacent programs 3 Compatibility with other identification systems which are already working Il sistema prescelto da un gruppo di lavoro specialistico int
9. eck for breathing e Do not break any blisters that have formed remove any clothing or fabric that is stuck to the skin apply adequate ointment If there is no breathing start artificial respiration without delay Figure 2 as follows tilt the head backwards pinch the nostrils seal your mouth around the victim s mouth and give four fast o If needed have the victim change into clean rescue breaths dry clothing e Administer adequate treatment for the type of accident Get the victim to a hospital as quickly as possible e Elevate arms and legs if injured Figure 2 e Check for heartbeat Figure 3 if there is no heartbeat begin chest compressions immediately Figure 4 placing your hands in the centre of the victim s chest Figure 5 ES KRA Figure 3 Figure 4 Figure 5 e One rescuer give 2 quick rescue breaths after each 15 compressions e Two rescuers one rescue breath after each 5 compressions 2 10 Rev 1 0 29 11 11 User Manual ELETTRONICA 4 1 4 2 4 2 1 TRDS4002 LUXOR B General Description The TRDS4002 LUXOR B manufactured by R V R Elettronica SpA is a RDS Coder basic model without display The TRDS4002 LUXOR B are designed to being contained into a 19 rack box of 1HE Unpacking The package contains E 1 TRDS4002 LUXOR B m 1 User Manual E 1 Mains power cable The following accessories are also available from Your R
10. el eine e Call for medical help as soon as possible 40138 BOLOGNA ITALY i Tel 39 051 6010506 3 2 Treatment of electric burns First Aid 3 2 1 Large burns and broken skin l e Cover affected area with a clean cloth or All personnel engaged in equipment installation operation linen and maintenance must be familiar with first aid procedures and routines Do not break any blisters that have formed remove any clothing or fabric that is stuck to 3 1 Electric shock treatment ine Sri apply ANAE clntinent a l e Administer adequate treatment for the type of 3 1 1 If the victim is unconscious accident e Get the victim to a hospital as quickly as Follow the first aid procedures outlined below possible Lay the victim down on his her back on a firm Elevate arms and legs if injured surface the neck and tilt the head backwards to free If medical help is not available within an hour the victim is conscious and is not retching administer a solution of table the airway system Figure 1 salt and baking soda one teaspoon of table salt to half teaspoon of baking soda every 250 ml of water Have the victim slowly drink half a glass of solution for four times during a period of 15 minutes Stop at the first sign of retching Do not administer alcoholic beverages 3 2 2 Minor burns e Apply cold not ice cold strips of gauze or dress wound with clean cloth Figure 1 If needed open the victim s mouth and ch
11. ernazionale prevede la trasmissione dei dati ad una velocit di 1187 5 bit sec con modulazione di fase a due livelli portante 57 KHz e banda 2 KHz The system selected by an international specialistic team allows the data transmission at a speed of 1187 5 bit sec with phase modulation at two levels carrier wave 57 Mhz and range 2 Khz The broadcasted binary signal is in advance put out on a differential codification The registry of transmission is at packages of lenght 104 bits 87 6 ms named GROUPS each of them composed of 4 blocks of 26 bits Every block is composed of 16 bits of information and of 10 bits of protection which are properly studied to allow the recovery of an erroneous word with a maximum of 5 wrong bits They are provided with 16 separete blocks of which 6 are still not defined every group begins with a PI identification code Program Identification which has the double intent to synchronize the receiver and to identify the channel which transmits the signal The pourpose of the encoder TRDS4002 LUXOR B is to manage the principal services defined by the standard CENELEC EN 5006 7 as PI PS PTY TP AF TA DI M S PIN RT EON TDC IH CT As follows we ll mention a short description about the function of each of these services PI PROGRAM IDENTIFICATION it s the identification code of the radio Its more important application is to allow the receiver in case of bad reception to implement the
12. n power panel and make sure the safety earth connection is connected Some service situations may require inspecting the equipment with live circuits Only trained and qualified personnel may work on the equipment live and shall be assisted by a trained person who shall keep ready to disconnect power supply at need R V R Elettronica S p A shall not be liable for injury to persons or damage to property resulting from improper use or operation by trained untrained and qualified unqualified persons A WARNING The equipment is not water resistant Any water entering the enclosure might impair proper operation To prevent the risk of electrical shock or fire do not expose this equipment to rain dripping or moisture Please observe local codes and fire prevention rules when installing and operating this equipment A WARNING This equipment contains exposed live parts involving an electrical shock hazard Always disconnect power supply before removing any covers or other parts of the equipment Ventilation slits and holes are provided to ensure reliable operation and prevent overheating do not obstruct or cover these slits Do not obstruct the ventilation slits under any circumstances The product must not be incorporated in a rack unless adequate ventilation is provided or the manufacturer s instructions are followed closely A WARNING This equipment can radiate radiofrequency energy and if not installed in compliance with manual
13. ns as specified in the licence 2 Warranty LaR V R Elettronica S p A warrants this product to be free from defects in workmanship and its proper operation subject to the limitations set forth in the supplied Terms and Conditions Please read the Terms and Conditions carefully as purchase of the product or acceptance of the order acknowledgement imply acceptance of the Terms and Conditions For the latest updated terms and conditions please visit our web site at WWW RVR IT The web site may be modified removed or updated for any reason whatsoever without prior notice The warranty will become null and void in the event the product enclosure is opened the product is physically damaged is repaired by unauthorised persons or is used for purposes other than its intended use as well as in the event of improper use unauthorised changes or neglect In the event a defect is found follow this procedure 1 Contact the seller or distributor who sold the equipment provide a description of the problem or malfunction for the event a quick fix is available Sellers and Distributors can provide the necessary information to troubleshoot the most frequently encountered problems Normally Sellers and Distributors can offer a faster repair service than the Manufacturer would Please note that Sellers can pinpoint problems due to wrong installation 2 If your Seller cannot help you contact R V R Elettronica S p A and describe the problem if ou
14. r staff deems it appropriate you will receive an authorisation to return the equipment along with suitable instructions 3 When you have received the authorisation you may return the unit Pack the unit carefully before shipment use the original packaging whenever possible and seal the package perfectly The customer bears all risks of loss i e R V R shall not be liable for loss or damage until the package reaches the R V R factorys For this reason we recommend insuring the goods for their full value Returns must be sent on a C I F basis PREPAID to the address stated on the authorisation as specified by the R V R Service Manager User Manual Rev 1 0 29 11 11 1 10 WR ELETTRONICA Zz Units returned without a return authorisation may e Do not stop chest compressions while giving be rejected and sent back to the sender artificial breathing 4 Be sure to include a detailed report mentioning all e Call for medical help as soon as possible problems you have found and copy of your original SD l invoice to show when the warranty period began with 3 1 2 If the victim is conscious the shipment ee Cover victim with a blanket Please send spare and warranty replacement parts orders to the address provided below Make sure to specify equipment e Try to reassure the victim model and serial number as well as part description and Loosen the victim s clothing and have him her quantity lie down Via d
15. z 50qB Internal external Adjustable up to 360 degrees RDS phase adjustment in 0 33 degree increments 24 bit Dynamic range 105aB 24 bit Dynamic range 123dB DSP elaboration 32 bit fixed point 3 RS232 DB9 Connector 1 USB Optional 1200 to 115200 Baud 1 RJ45 Connector Optional REMOTE input 8 Input 8 Output Optional EN60215 1997 EN 301 489 11 V1 4 1 8 10 Rev 1 0 29 11 11 User Manual 5 Identification of the Modules TRDS4002 LUXOR B The TRDS4002 LUXOR B is made up of various modules linked to each other through connectors so as to make maintenance and any required module replacement easier 5 1 Upper View The figure below shows the equipment upper view with the various components pointed out Figure 5 1 1 Power Supply 2 Panel Card 3 CPU amp I O Card User Manual This page was intentionally left blank 10 10 Rev 1 0 29 11 11 User Manual ISO 9001 2000 certified since 2000 R V R Elettronica S p A Via del Fonditore 2 A 2c KINN Member of CISQ Federation Zona Industriale Roveri 40138 Bologna Italy AN RIN aa ed adh waht Phone 39 051 6010506 Fax 39 051 6011104 SEA iso 9001 2000 Certified Quality System ELETTRONICA e mail info rvr it web http www rvr it The RVR Logo and others referenced RVR products and services are trademarks of RVR Elettronica S p A in Italy other countries or both RVR 1998 all rights