Data Sheet DB EN IL EIP BK DI8 DO4 2TX-PAC
Contents
1. 64 Byte Enter Password Reboot Figure 15 PCP configuration in web based management 7537_en_00 www phoenixpowersupply co uk 24
2. In the event of an error in the Inline station this is indicated in the diagnostic registers The D LED flashes on the bus coupler The process data is invalid because only internal values are indicated not the values on INTERBUS In order to make sure that only valid data is displayed the diagnostic register must also always be requested The same is valid in the event of a faulty configuration In this case INTERBUS does not run and only internal values can be read in the XML file In the event of a peripheral fault all data is valid except for the data of the faulty terminal lt xml version 1 0 encoding ISO 8859 1 gt lt DOCTYPE IL_STATION View Source for full doctype gt lt IL_STATION gt lt IL_BUS_TERMINAL gt lt TERMINAL_TYPE gt IL EIP BK DI8 DO4 lt TERMINAL_TYPE gt lt NAME gt IL EIP BK DI8 DO4 2TX PAC lt NAME gt lt IP_ADDRESS gt 172 16 113 38 lt IP_ADDRESS gt lt MODULE_NUMBER gt 6 lt MODULE_NUMBER gt lt IL_BUS_TERMINAL gt lt IL_BUS gt lt IL_MODULE number 1 gt lt MODULE_TYPE gt DO lt MODULE_TYPE gt lt PD_CHANNELS gt 4 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_OUT word 1 gt 0 lt PD_OUT gt lt IL_MODULE gt lt IL_MODULE number 2 gt lt MODULE_TYPE gt DI lt MODULE_TYPE gt lt PD_CHANNELS gt 8 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_IN word 1 gt 0 lt PD_IN gt lt IL_MODULE gt lt IL_MODULE number 3 gt lt MODUL
3. Access to WBM is no longer possible a 7537_en_00 PHOENIX CONTACT 18 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 13 6 Process Data Access via XML The integrated web server of the IL EIP BK DI8 DO4 2TX PAC offers the option of accessing the process data of the connected Inline terminals via a web page in XML format You can access the web pages via a standard web browser To access the XML pages with the process data in the address line of the browser enter the address in the following format http lt IP address gt procdata xml 13 7 XML File Structure The XML file contains different data areas IL_STATION Frames for the entire XML file The mandatory elements of this frame are IL_BUS_TERMINAL and IL_BUS IL_BUS_TERMINAL This data area contains information on the entire Inline station bus coupler and all connected terminals This data area includes TERMINAL_TYPE This area contains the name of the bus coupler which is always IL EIP BK DI8 DO4 2TX PAC NAME Contains the user specific station name The station name can be modified via WBM IP_ADDRESS Contains the IP address of the station MODULE_NUMBER Contains the number of connected Inline terminals including local I Os In the event of a bus error the number of the last known operable configuration is indicated DIAGNOSTIC_STATUS_REGISTER Contains the INTERBUS status represented by all bits of the di
4. State Description of the LED States ETH LNK1 Green Link at ON Link connection at port 1 present ort 1 p OFF Link connection at port 1 not present LNK2 Green Link at ON Link connection at port 2 present ort 2 j OFF Link connection at port 2 not present ACT1 Yellow Activity ON Data transmission on port 1 active on port 1 al 7 OFF Data transmission on port 1 not active ACT2 Yellow Activity ON Data transmission on port 2 active on port 2 ae 7 OFF Data transmission on port 2 not active PWR BO Green Boot ON Boot loader active firmware started Flashing Waiting for BootP DHCP reply OFF Firmware started successfully UL Green ULogic ON 24 V communications supply 7 5 communications power present OFF 24 V communications supply 7 5 communications power not present 7537_en_00 PHOENIX CONTACT 10 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC LED Color Meaning State Description of the LED States US Green Usegment ON 24 V segment circuit supply present OFF 24 V segment circuit supply not present UM Green Umain ON 24 V I O supply present OFF 24 V I O supply not present RY Green Ready Ready ON Connection to a process data client established Flashing Firmware ready to operate OFF Firmware not active MS Red Module Device status gregn al a Green ON Normal operation Red ON Unrecoverable error Flashing green Device not configured
5. configuration be operated Set station to RUN state Stop Station in RUN state MS LED dlashing D LED flashing MS LED green D LED ON Error cause in local bus diagnostic registers 75370007 Figure 14 P amp P mode active 7537_en_00 PHOENIX CONTACT 23 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 15 Configuration of the PCP PDU Size The standard PDU size for communication with all Phoenix Contact Inline devices is 64 bytes in the transmit and receive direction System couplers such as the ILC 200 UNI have configurable PDU sizes If another size is configured and an IL EIP BK DI8 DO4 2TX PAC is used for communication the bus coupler must also be configured to the values already set on the ILC 200 UNI DESNA IL ETH BK DI8 DO4 IL ETH BK DI8 DO4 2TX PAC last update 10 12 03 General Instructions C Device Information C Device Configuration Inline Station B Services a Process Data Monitoring Remote Diagnostics Bus Configuration PCP Configuration Home PCP PDU Size Configuration Send Receive PDU Size CR 2 64 Byte 64 Byte PDU Size CR 3 64 Byte 54 Byte PDU Size CR 4 64 Byte 64 Byte PDU Size CR5 54 Byte 64 Byte PDU Size CRE 54 Byte 64 Byte PDU Size CR 7 64 Byte 54 Byte PDU Size CRB 64 Byte 64 Byte PDU Size CR 9 54 Byte
6. swupinfo htm Instructions LY ftpinfo htm Device Information Change Password Device password htm gt L____y passinfo htm E Inline Inline Station Station Services services htm gt svppinfo htm 3 swpfinfo htm Process Data Monitoring pdmonit htm gt gt pdmoninf htm b 3 pdnfinfo htm EtherNet IP Remote Diagnostics diag ht Figure 7 WBM homepage di Bus Configuration busconf htm gt PCP Configuration pcpconf htm pcpinfo htm Figure 8 Structure of the web pages 7537_en_00 PHOENIX CONTACT 17 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 13 3 IP Configuration Menu Figure 9 illustrates the set IP parameters and addressing mechanism To change the IP parameters via WBM BootP Requests must be set to Disable or BootP requests to the bus coupler must not be answered no BootP server can be active in the network IP Configuration IP Address fi 72 16 113 38 255 255 255 0 0 0 0 0 Please enter IP Address Subnet Mask and Gateway Address in dotted decimal notation e g 172 16 16 230 The changes will take effect after the reboot of the IL EIP BK DI8 DO4 I Subnet Mask Default Gateway Enter Password Reboot C Enable Disable Before disabling automatic BootP setting be sure to record the current IP address You will need the current IP address if you want to re enable BootP setting of the IP address If you forget the IP address t
7. the bus coupler is set to the RUN state If the reference configuration and the physical configuration differ the MS Module Status LED lights up and process data exchange is no longer possible for safety reasons In order to operate the bus you have the following two options 1 Restore the original configuration so that the reference configuration and the physical configuration are the same again 2 Activate P amp P mode and restart the bus coupler so that the active physical configuration is accepted as the reference configuration PHCENIX IL EIP BK DI8 DO4 2TX PAC last update 8 36 21 Di pa Services Plug amp Play IL EIP BK DI8 DO4 Plug amp Play E Ganwwal Mode Inputs Only Inputs amp Outputs Disable Instructions When in Plug and Play Mode during power up the Device Information buscoupler will automatically attempt to start the local 1 O Devi When disabled the buscoupler will compare the stored I O A configuration with the connected I O and start if equal Inline Station Note Reboot not required to implement changes D Servi Plug amp Play Mode Inputs amp Outputs Active a Process Data oa A Ae loni ing The IL EIP BK DI8 DO4 2TX PAC supports a P amp P mode A n s Di ti referred to as Inputs amp Outputs This mode allows the u O writing of outputs Care should be taken when setting a Configuration Click Store Config to acquire store and utilize the device to this mode A
8. web browser Web based management can be used to access static information e g technical data MAC address or dynamic information e g IP address status information or to change the configuration password protected 13 2 Structure of the Web Pages The web pages for the Ethernet IP bus coupler are divided into two sections The left hand side has the selection menu with the relevant submenus The right hand side displays the information related to the menu item Static and dynamic information about the bus coupler can be found in the following menus lt ip address gt index htm 13 1 Calling Web Based Management General Instrucions The IL EIP BK DI8 DO4 2TX PAC web server can be Information addressed using the IP address if configured geninsthtm i evice correspondingly The bus coupler homepage is accessed Information by entering the URL http lt P address gt General pi 1 172 16 ie 38 pies xample p 5 E i Technical Data techdata htm Hardware Installation LL gt e hwinstal htm If you cannot access the WBM pages check the Local Diagnostics connection settings in your browser and i locdiag htm j i Device deactivate the proxy if set Sentai gt IP Configuration ipconfig htm CEE IL EIP BK DIS DO4 2TX PAC last update 8 30 27 mu ue ystem Identification 5 sysconf htm 3 sysinfo htm Software Update IL EIP BK DI8 DO4 gt Suda htm General gt _
9. 0 22 mm 100 2 10 Mbps 10Base T 100 Mbps 100Base TX half duplex full duplex auto detection 100 m Through data routing 30 m maximum routing cables through outdoor areas is not admissible Through potential routing The supplies Uy Us and the bus coupler supply Ug do not have the same ground potential because they are supplied by two separate power supply units Voltages main and segment supply that are transferred from the bus coupler to the potential jumpers follow the supply voltages without delay 24VDC 7537_en_00 PHOENIXCONTACT 5 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Supply Voltage for U Us Uy Continued Permissible range according to EN 61131 2 19 2 V to 30 V ripple included O NOTE Module is damaged in the event of overload to ensure that it trips in the event of an error This 24 V area must be externally protected The power supply unit must be able to supply 4 times the nominal current of the external fuse A Observe the logic current consumption of each device when configuring an Inline station This information is given in every module specific data sheet The current consumption can differ depending on the individual module The permissible number of devices that can be connected therefore depends on the specific station structure Communications Power U 7 5 V and Analog Supply Uana The bus coupler supply U 24 V generates the commu
10. E IN6 24 V LT 24 L mns 3 11 Terminal Assignment Terminal Assignment Points Points Ethernet IP 1 1 N1 24 IN2 D hy ieee Figure 6 Connection example 1 2 Um 2 2 Um 13 GND 23 GND J internal jumper in the module 1 4 IN3 2 4 IN4 8 Mounting Removing Modules and Terminal Point Assignment of the Input Connector Connecting Cables 4 12 Installation Instructions Terminal Assignment Terminal Assignment To ensure that installation is carried out correctly Points Points please read the Installation Instructions for the Electrical Engineer supplied with the bus 3 1 INS 4 1 ING coupler Please also observe the information 3 2 Um 4 2 Un given in the IL SYS INST UM E user manual 3 3 GND 4 3 GND O NOTE Failure to observe this warning may th l 3 4 IN7 4 4 IN8 demagethamedue Before removing or mounting a module disconnect the power to the entire station Make sure the entire station is reassembled before switching the power back on 7537_en_00 PHOENIX CONTACT 14 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 9 Startup 9 1 Default Upon Delivery Default Settings By default upon delivery the following functions and features are available IP Configuration IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Default Gateway 0 0 0 0 BootP Requests Enable Software Update Software Update on Next Disable Reboot TFTP Server IP Address 0 0 0 0 Downloadable File Na
11. E_TYPE gt DO lt MODULE_TYPE lt PD_CHANNELS gt 32 lt PD_CHANNELS gt lt PD_WORDS gt 2 lt PD_WORDS gt lt PD_OUT word 1 gt 0 lt PD_OUT gt lt PD_OUT word 2 gt 0 lt PD_OUT gt lt IL_MODULE gt lt IL_MODULE number 4 gt lt MODULE_TYPE gt DI lt MODULE_TYPE gt lt PD_CHANNELS gt 32 lt PD_CHANNELS gt lt PD_WORDS gt 2 lt PD_WORDS gt lt PD_IN word 1 gt 0 lt PD_IN gt lt PD_IN word 2 gt 0 lt PD_IN gt lt IL_MODULE gt lt IL_MODULE number 5 gt lt MODULE_TYPE gt AIO lt MODULE_TYPE gt lt PD_CHANNELS gt 2 lt PD_CHANNELS gt lt PD_WORDS gt 2 lt PD_WORDS gt lt PD_IN word 1 gt 1 lt PD_IN gt lt PD_IN word 2 gt 0 lt PD_IN gt lt PD_OUT word 1 gt 0 lt PD_OUT gt lt PD_OUT word 2 gt 0 lt PD_OUT gt lt IL_MODULE gt lt IL_MODULE number 6 gt lt MODULE_TYPE gt AO lt MODULE_TYPE gt lt PD_CHANNELS gt 1 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_OUT word 1 gt 0 lt PD_OUT gt lt IL_MODULE gt lt IL_BUS gt lt IL_STATION gt 4 lt DIAGNOSTIC_STATUS_REGISTER gt 224 lt DIAGNOSTIC_STATUS_REGISTER gt lt DIAGNOSTIC_PARAMETER_REGISTER gt 0 lt DIAGNOSTIC_PARAMETER_REGISTER gt Adresse ES http 172 16 113 38 procdata xml wechseln zu Links E Data of Inline Station ons Diagnostic Register Data of the first digital Output terminal Data of the first digital Input terminal Figure11 Screen for XML data E Internet 7537_en_00
12. IL EIP BK DI8 DO4 2TX PAC Inline Bus Coupler for Ethernet IP With Eight Digital Inputs and Four Digital Outputs AUTOMATION nee 1 Description 1 1 Module Features 2x Ethernet twisted pair according to 802 3 with auto negotiation and auto crossover connected via an integrated 3 port switch 2 external ports 1 internal port Ethernet connection via 8 pos RJ45 female connector Ethernet TCP IP with 10 100 Base T X The bus coupler is the interface between the Ethernet IP network and the Inline installation system With the help of a bus coupler 61 Inline terminals can be connected at any position within an existing Ethernet IP system The bus coupler and the Inline terminals form a station with 63 local bus devices Here the inputs and Industrial Ethernet IP Version 1 2 outputs of the bus coupler form the firstand second localbus Process data access via XML devices Web based management WBM Up to eight PCP devices can be operated on the bus P parameter configuration coupler BootP DHCP WBM Static IP Integrated web server Eight digital inputs Four digital outputs Diagnostic and status indicators For additional information please refer to the UM EN IL EIP BK DI8 DO4 2TX PAC user manual see Documentation on page 4 This data sheet is only valid in association with the IL SYS INST UM E user manual see Documentation on page 4 Make sure you always use t
13. IL_MODULE number 1 gt lt MODULE_TYPE gt DI lt MODULE_TYPE gt lt PD_CHANNELS gt 2 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_IN word 1 gt 3 lt PD_IN gt lt IL_MODULE gt b Inline terminal with two digital inputs and only the second input is active lt IL_MODULE number 3 gt lt MODULE_TYPE gt DI lt MODULE_TYPE gt lt PD_CHANNELS gt 2 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_IN word 1 gt 2 lt PD_IN gt lt IL_MODULE gt c Inline terminal with 16 digital inputs and the 13th and the 14th input are active lt IL_MODULE number 7 gt lt MODULE_TYPE gt DI lt MODULE_TYPE gt lt PD_CHANNELS gt 16 lt PD_CHANNELS gt lt PD_WORDS gt 1 lt PD_WORDS gt lt PD_IN word 1 gt 12288 lt PD_IN gt lt IL_MODULE gt The input word returns the value 12288 21 213 d Inline terminal with two analog inputs only the first channel being active 14970 lt IL_MODULE number 10 gt lt MODULE_TYPE gt Al lt MODULE_TYPE gt lt PD_CHANNELS gt 2 lt PD_CHANNELS gt lt PD_WORDS gt 2 lt PD_WORDS gt lt PD_IN word 1 gt 14970 lt PD_IN gt lt PD_IN word 2 gt 8 lt PD_IN gt lt PD_OUT word 1 gt 0 lt PD_OUT gt lt PD_OUT word 2 gt 0 lt PD_OUT gt lt IL_MODULE gt 7537_en_00 www phoenixpowersupply co uk PHOENIX CONTACT 20 IL EIP BK DI8 DO4 2TX PAC PD_OUT This area is used by all terminals with output data The use of bits is identical to the use of PD_IN
14. MC Directives Developed according to IEC 61000 6 2 IEC 61000 4 2 ESD Criterion B 6 kV contact discharge 6 kV air discharge without labeling field 8 kV air discharge with labeling field IEC 61000 4 3 radiated noise immunity Criterion A IEC 61000 4 4 burst Criterion B IEC 61000 4 5 surge Criterion B IEC 61000 4 6 conducted noise immunity Criterion A IEC 61000 4 8 noise immunity against magnetic fields Criterion A EN 55011 noise emission Class A Approvals Information on current approvals can be found on the Internet at www download phoenixcontact com or www eshop phoenixcontact com 7537_en_00 PHOENIX CONTACT 8 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 4 Circuit Diagram Dress 7275A005 Figure 1 Circuit diagram of the Ethernet Bus Coupler uP Microprocessor The gray areas in the circuit diagram represent the electrically isolated areas Protocol chip A Ethernet interface e ee Optocoupler ES i n B Ethernet switch PNP transistor Transmitter with electrical isolation 7537_en_00 PHOENIX CONTACT 9 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 5 Local Diagnostic and Status Indicators 75370002 Figure 2 Indicators on the bus coupler LED Color Meaning
15. PHOENIX CONTACT 21 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 14 Startup Behavior of the Bus Coupler The startup behavior of the bus coupler is specified via the system parameter Plug amp Play P amp P The P amp P mode can be set to one of three states Inputs Only Inputs amp Outputs and Disabled By default upon delivery P amp P mode is enabled to the Inputs amp Outputs setting Plug amp Play Mode Inputs Only Active The IL EIP BK DI8 DO4 2TX PAC supports a P amp P mode referred to as Inputs Only This mode enables Inline terminals connected in the field to be started up using the bus coupler without a higher level configuration The P amp P mode status Inputs Only Inputs amp Outputs and Disabled is stored retentively on the bus coupler The current mode is accessible via the WBM interface or the CIP interface In P amp P mode the connected Inline terminals are detected and their ability to operate is checked If this physical configuration is ready to operate it is started however writing outputs is not enabled To enable writing outputs P amp P mode must be either deactivated or set to Inputs amp Outputs The deactivation of P amp P mode is also the signal to save the active configuration as the reference configuration Plug amp Play Mode Disabled When P amp P mode is disabled or deactivated the reference configuration is compared to the physical configuration If they are the same
16. Points following table 1 1 Us 2 1 Um Pin Assignment 1 2 UL 2 2 Um 1 TXD transmit data 1 3 GND UL 2 3 GND Un Us 2 TxD transmit data 1 4 Functional 2 4 Functional earth ground earth ground 3 RxD receive data FE j FE j 4 Reserved 5 Reserved NOTE Module is damaged in the event of overload PXD receive data 7 The GND Uy Us potential jumper carries the total 7 Reserved current of the main and segment circuits The total current must not exceed the maximum 8 Reserved current carrying capacity of the potential jumpers 8 A If in the course of configuring it is found Both Ethernet interfaces h ve an auto crossover thatthe 8 A limit is reached at one of the potential jumpers Us Uy and GND a new power terminal function must be used The functional earth ground must be connected to the 24 V DC supply functional earth ground connection 7537_en_00 PHOENIX CONTACT 13 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Terminal Point Assignment of the Output Connector 2 01 Terminal Assignment Terminal Assignment Points Points 1 1 OUT1 2 1 OUT2 1 2 GND 2 2 GND 1 3 FE 2 3 FE 1 4 OUT3 2 4 OUT4 Terminal Point Assignment of the Input Connector 7 3 Connection Example Connect the bus coupler according to Figure 6 J PWRDO4 DI4 DI4 I 2 3
17. X3 5 Type IPAssign exe Type UM EN IL EIP BK DI8 DO4 2TX PAC AH IL BK IO LIST ILSYS INST UME Order No 2897758 Order No 2878599 2744856 2744571 1734634 1051003 0812120 2727501 2727515 0809492 0809502 0801733 0801681 3022276 1201442 Order No 2744814 2744830 2744513 Order No 2744869 1204517 Order No Pcs Pkt 4 Pcs Pkt 1 2 2 100 10 10 10 10 1 50 50 Pcs Pkt 1 meter 1 meter 1 Pcs Pkt 1 10 Pcs Pkt This software can be downloaded at www download phoenixcontact com Order No 9015358 2698737 Pcs Pkt 7537_en_00 www phoenixpowersupply co uk PHOENIXCONTACT 4 IL EIP BK DI8 DO4 2TX PAC 3 Technical Data General Data Housing dimensions width x height x depth Weight Ambient temperature operation Ambient temperature storage transport Permissible humidity storage transport Permissible air pressure operation storage transport Degree of protection Class of protection Preferred mounting position Connection to functional earth ground Ambient compatibility Resistance to solvents Connection data for Inline connectors Connection type Conductor cross section System Limits of the Bus Coupler Number of devices per station Number of I O data Transmission rate on the local bus Power supply at U 7 5 V Power supply at Uama Power supply at Ug Power supply at Uy Interfaces Ethernet Type Number Co
18. agnostic status register A detailed description can be found in the diagnostic parameter register Whenever an error bit is set the diagnostic parameter register is rewritten IL_BUS Frame for the connected Inline terminals IL_MODULE Frame for the data of an individual Inline terminal The terminals are numbered consecutively from one to a maximum of 63 MODULE_TYPE Contains the terminal type Possible types are DI DO DIO Al AO AlO and PCP PD_CHANNELS Number of process data channels in an Inline terminal For digital terminals the number of channels is equal to the number of supported bits For other terminals the number of process data words is indicated Example An IB IL AO 2 has two process data channels and an IB IL 24 DO 8 has eight bits and therefore eight process data channels PD_WORDS Number of process data words in an Inline terminal Please note that analog terminals always have the same number of output and input words An IB IL AO 2 therefore also has two input words and an IB IL Al 2 also has two output words PD_IN This area is used by all terminals that occupy input data The number of process data words depends on the terminal type PD_OUT This area is used by all terminals that occupy output data see also PD_OUT on page 21 7537_en_00 PHOENIX CONTACT 19 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Examples a Inline terminal with two active inputs lt
19. ctions allows for faster scanned data update and therefore affects the maximum number of connections A lower number of connections allows for faster data update RPI value To obtain the maximum I O performance the number of connections should be limited to eight maximum 12 CIP Object Classes The IL EIP BK DI8 DO4 2TX PAC supports the following CIP object classes Class Code Object Type dec hex 01 01 Identity Object 02 02 Router Object 04 04 Assembly Object 05 05 Connection Object 06 06 Connection Manager Object 08 08 Digital Input Point DIP Object 09 09 Digital Output Point DOP Object 10 OA Analog Input Point AIP Object 11 OB Analog Output Point AOP Object 43 2D ___ Acknowledge Handler Object 100 64 Configuration Object 101 65 Inline Interface Object 102 66 Inline Module Object 103 67 Inline Special Function Object 104 68 COS Mask Object 105 69 PCP Object 106 6A _ Serial Object 244 F4 Port Object 245 F5 TCP IP Interface Object 246 F6 Ethernet Link Object 7537_en_00 PHOENIX CONTACT 16 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 13 Web Based Management WBM The IL EIP BK DI8 DO4 2TX PAC has a web server which generates the required pages for web based management and depending on the requirements of the user sends them to the Factory Manager or a standard
20. ent WBM oooococccnnnnccccononcccnnnnnnnnnnnnnncnnnnnnnncnc ron cnn cnn nr rn nana nn narran nn nana ner 17 13 1 Calling Web Based Management ccecceeceeeeeceeeeeneeseeeeeeeseeeeaeeeaeeseeeeeaeeseeeeaeesaeeseaeeeeeseeeeeaeeseeeeeaeeeaeen 17 13 2 Structure of the Web Pages ccccccescsessceceseeseeeeanesseeseaeeeanecaeeeaeecseesaesaeeesaeseaeeeaeesaeseaaeeaeeeeeseaeeeaneenerees 17 13 3 IP Gonfiguration Men cia ii 18 13 4 Password Protections ipia aa aa a aaa a aar aa EA OEA raa e a Eea a eneee ia iaae 18 13 5 Firmware Update via WBM and TFTP 1 0 0 eeeseeeeseeeeeeeeeeeneeeeeneeeseaeeeseaeeeeaeeeseaeeeeeaeeeesaeeesaeeeeeeeeneeeseneeeees 18 13 6 Process Data Access Mia XML citan 19 13 77 XML File Structure aspira iaa 19 14 Startup Behavior of the Bus Coupler ooocconnocccinnncccccnoonnnnononancnnnnannncno nono nnnnnnn ne nnrnnnnnnnn nena re nananane 22 15 Configuration of the PCP PDU Size 0 iii das 24 7537_en_00 PHOENIX CONTACT 3 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 2 Bus Coupler Description Inline bus coupler for Ethernet IP with eight digital inputs and four digital outputs including accessories end plate Inline connector and labeling fields Accessories Description Connector set for Inline bus coupler with connected I Os Gray RJ45 connector set for linear cable Green RJ45 connector set for crossed cable Keying profile Zack marker strip to label the terminal
21. he latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www downl phoenixcontact com general 7000_en_00 pdf r me oe DOD OO GD GD OGD 0 OOD Long ODE www phoenixpowersupply co uk INSPIRING INNOVATIONS IL EIP BK DI8 DO4 2TX PAC 1 2 Inline Features Up to 61 other Inline modules can be connected process data channel Up to eight other PCP modules can be connected Can be installed in the field software for automatic configuration of the station is not required Automatic baud rate detection on the local bus 500 kbaud or 2 Mbaud Ethernet and CIP Features Electrical isolation of Ethernet interface and logic Type of device profile OChex communication adapter Supported CIP connections in total 128 eight typical Explicit signaling Max number of connections 128 eight typical 1 O signaling Max number of connections 128 eight typical Device configuration possibilities EDS individual software MAC parameter configuration rate 10 Mbps 100 Mbps automatic duplex half full automatic 7537_en_00 www phoenixpowersupply co uk PHOENIX CONTACT 2 IL EIP BK DI8 DO4 2TX PAC Table of Contents T geste ccstaticcs eet rete ai aaeece aha cies aries texan AE ODE NEKE Eak AA ta EAA RAT AAA AREAN tebe tees 1 1 1 ModulesFe atures iii its 1 1 2 Inline Features ici AAA a aR A ee 2 1 3 Etherneta
22. he only way is to delete the whole configuration over the Reconf Button m IP Configuration menu BootP Requests Enter Password Apply Figure 9 13 4 Password Protection All status changes to the bus coupler require the entry of a password The password can be changed at any time Your unique password must be between four and twelve characters long please note that it is case sensitive By default upon delivery the password is private If you forget the password the only way to access the bus coupler again is to reset the entire config uration using the reset button A 13 5 Firmware Update via WBM and TFTP The following steps must be carried out when executing a firmware update using WBM In WBM click on Device Configuration and then Software Update Enter the IP address of the TFTP server in the TFTP Server IP Address field Then enter the file name of the firmware and the path name if necessary in Downloadable File Name In the Software Update on Next Reboot field click Enable Enter your password To wait until later to apply the update with a restart click Apply To start the update immediately click Apply and Reboot Check the execution of the update by checking the firmware version under Device Information General In the event of an error during the download a restart repeats the download To abort the update set Disable in the Sof
23. hod for sensors Input design Definition of switching thresholds Maximum low level voltage Minimum high level voltage Common potentials Nominal input voltage Uy Permissible range Nominal input current for Ujy Current flow Delay time Permissible cable length to the sensor Use of AC sensors Safety equipment Error message to the higher level control system Mechanical Requirements Vibration test sinusoidal vibrations according to IEC 60068 2 6 EN 60068 2 6 Shock test according to IEC 60068 2 27 EN 60068 2 27 Mechanical Tests Shock test according to EN 60068 2 27 Vibration resistance according to IEC 60068 2 6 Free fall according to IEC 60068 2 32 8 2 and 3 wire technology According to EN 61131 2 Type 1 Ui max lt 5 V Unmin gt 15 V Sensor supply Uy ground 24 VDC 30 V lt Un lt 30 V DC 3 mA typical Limited to a 3 mA maximum lt 500 ms 100 m AC sensors in the voltage range lt Uyy are limited in application Surge voltage polarity reversal Sensor supply not present 5g load 2 hours in each space direction 25g load for 11 ms half sinusoidal wave three shocks in each space direction and orientation Operation 25g 11 ms period half sine shock pulse Storage transport 50g 11 ms period half sine shock pulse Operation storage transport 5g 150 Hz Criterion A 1m 7537_en_00 PHOENIXCONTACT 7 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Conformance With E
24. me c2897758 fw System Identification Name of Device IL EIP BK DI8 DO4 2TX PAC Description Ethernet IP Bus Terminal Physical Location Unknown Contact Unknown Process Data Monitoring Process Data Watchdog Oms Timeout Fault Response Mode Reset Fault Mode Default Plug and Play Mode Enable 9 3 Sending BootP Requests Initial Startup During initial startup the device sends BootP requests without interruption until it receives a valid IP address The requests are transmitted at varying intervals 2 s 4s 8s 2 s 4s etc so that the network is not loaded unnecessarily If valid IP parameters are received they are saved as configuration data by the device Restart By default the device will send BootP requests indefinitely until it receives a valid reply This action can be changed to limit three BootP requests on a restart which reverts to using the previous configuration parameters See the UM EN IL EIP BK DI8 DO4 2TX PAC User Manual under the Configuration Object section for details 10 Ethernet IP Object Classes The Inline bus coupler supports CIP by means of digital input points DIP digital output points DOP analog input points AIP and analog output points AOP according to the ODVA specification Additional objects include User Defined Configuration Inline Interface Inline Module Inline Special Function PCP Special Function and Serial Communica
25. mismatched I O system configuration O cmo Fisica ON BT UA SMa CORE Y OE which is connected to end devices such as drive controls or J Home function motion controls can cause unwanted actions when outputs es are turned on Users must ensure in this P amp P mode that any di A connected end device will safely function if outputs are Figure 12 Plug amp Play mode enabled P amp P Mode Description Effect Diagram Disabled Normal case the station sets valid configurations to the RUN state Figure 13 on Process data exchange is possible page 23 Inputs Only The connected configuration is stored as the reference configuration and the Figure 14 on station is set to the RUN state Process data cannot be written page 23 Inputs 8 Outputs The connected configuration is stored as the reference configuration and the Figure 14 on station is set to the RUN state Process data exchange is possible page 23 7537_en_00 PHOENIX CONTACT 22 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Startup Diagrams for the Bus Coupler Load and activate saved configuration onfiguration reference configuration Set station to RUN state Stop Station in RUN state MS LED flashing D LED flashing Error cause in local bus diagnostic registers or in WBM MS LED green D LED ON 75270006 Figure13 Standard mode P amp P mode inactive Read in connected configuration Can
26. mption of each device when configuring an Inline station This information is given in every module specific connected therefore depends on the specific station structure Digital Outputs Number Connection method for actuators Nominal output voltage Ugut Differential voltage at lhom Nominal current Inom per channel Total current 4 2 and 3 wire technology 24 VDC lt 1V 0 5A 2A 7537_en_00 PHOENIX CONTACT www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC Digital Outputs Continued Protection Nominal load Ohmic Lamp Inductive Switching frequency with nominal inductive load Overload response Response with inductive overload Reverse voltage protection against short pulses Resistance to permanently applied reverse voltages Response upon power down Limitation of the voltage induced on circuit interruption Safety equipment Overcurrent shutdown Maximum output current when switched off Short circuit overload 12W 12W 12 VA 1 2 H 0 5 Hz 1 2 H maximum Auto restart Output may be damaged Protected against reverse voltages Protected against reverse voltages permissible current 2 A maximum The output follows the supply voltage without delay 30 0 V approximately Integrated free running circuit in the output chip 0 7 A minimum 10 pA la When not loaded a voltage can be measured even at an output that is not set Digital Inputs Number Connection met
27. nd GIP Features cuisine 2 E OMASUING Dette es ves E E EE E eh eaves ee ede eA tad ASSN aR E eae oes 4 3 Technical Dala a 5 47 Circuit A A neta e Aha teks costes whee eatin ae e tees i cola Pett NE I E 9 5 Local Diagnostic and Status Indicators iia bdo iaa es ase 10 o 12 7 Connecting Ethernet the Supply Actuators and Sensors ooooccccccnocccnnnoncccnnnnannnnnnnancnnnannccncnns 13 7 1 Connecting Etheme tesisinin pier eiet a a io 13 7 2 Connecting the Supply Actuators and S NSOIS cccceeceeeeeeeeeeeeeeeeeeeeeeeeeeaeeeaeeseeeeaaeeeaeeseeeseeeeeaeesaeeeneetaas 13 7 3 gt Connection Example tica Bele ah A ee le that aoe a aa 14 Mounting Removing Modules and Connecting Cables ccccccecceeeeeeeeeeeeeeeeeeeeeeeesaeeteenneees 14 A A a Deedes acetoacetate eect 15 9 1 Default Upon Delivery Default Settings ec eeceeeceeeneeeeeeeeeeeeeeeeaeeeaeeseaeeeaeeeeesaaeeeaeeeaeeseeseaeeeaeessaeseaeeeneeeaas 15 9 2 Stating he AMV aE a coccion iii eae EE aa iaiia 15 9 3 Sending BootP Requests 4 ini dele da 15 10 EthermnetIP Object Classes ii A A 15 11 Operating Directives for the SySteM oooonncccnnnnccccnnnccccncnocnncnnnannncnnnnnnnnnn naar nr nrnnnn cnn nr n rra 16 11 1 Repeat Packet Interval RPI Settings ooonocinccnnncnnnnnnnnccnncnnncnnonccnnccnnnn nac cnnn cnn crac nn rara nn narran 16 11 2 Maximum ComectioN cuisine aiii 16 12 CIP Object Glas SES petite e td ia dl ee ee 16 13 Web Based Managem
28. nications power U 7 5 V and the analog supply U ana 24 V for the Inline station Communications Power Potential Jumper Nominal value Maximum output current Safety equipment Analog Supply Potential Jumper Nominal value Maximum output current Safety equipment Current Consumption Power Consumption Current consumption from U 24 V Current consumption of module electronics Current consumption of local bus 800 mA load at 7 5 V Current consumption from Uana 24 V Total current consumption from U Current consumption from Ug 24 V Current consumption from Uy 24 V Power dissipation of entire device Bus Interface of the Lower Level System Bus Interface Electrical isolation Number of Inline terminals that can be connected Limitation by software Limitation by power supply unit 7 5V DC 2 A DC observe derating Electronic short circuit protection 24V DC 0 5 A DC observe derating Electronic short circuit protection 0 08 A maximum 0 4 A maximum 0 5 A maximum 0 98 A maximum 3 mA 4 mA for each output set load typical 8 A maximum 3 mA 3 mA for each output set load typical 8 A maximum 3 W typical Inline local bus No 63 maximum Maximum logic current consumption of the connected local bus modules Imax lt 2 ADC data sheet The current consumption can differ depending on the individual module The permissible number of devices that can be A Observe the logic current consu
29. nnection format Connection medium Cable impedance Transmission speed Maximum network segment extension Local bus Supply Voltage for UL Us Uy Recommended cable lengths Continuation Special demands on the voltage supply Behavior in the event of voltage fluctuations Nominal value 80 mm x 121 mm x 70 mm 270 g with connectors 25 C to 60 C 25 C to 85 C 10 to 95 according to EN 61131 2 70 kPa to 106 kPa up to 3000 m above sea level IP20 according to IEC 60529 Class 3 according to EN 61131 2 IEC 61131 2 Perpendicular to a standard DIN rail The functional earth ground must be connected to the 24 V DC supply functional earth ground connection The contacts are directly connected to the potential jumper and FE springs on the bottom of the housing The terminal is grounded when it is snapped onto a grounded DIN rail Functional earth ground is only used to discharge interference Free of substances which would hinder coating with paint or varnish Resistant to standard solvents Spring cage terminals 0 2 mm to 1 5 mm solid or stranded 24 16 AWG 63 maximum including two devices on the bus coupler 512 bytes maximum 500 kbps or 2 Mbps automatic detection 0 8 A maximum 0 5 A maximum 8 A maximum 8 A maximum Ethernet 10Base T and 100Base TX with auto negotiation and auto crossover Two 8 pos RJ45 female connector CAT 5 twisted pair cable with a conductor cross section of 0 14 mm to
30. on the front side of the bus coupler It has two functions Restarting the bus coupler Restoring the default settings For restoring the default settings see Startup on page 15 the reset button must be pressed when the voltage is applied Ethernet IP EtherNew IP RESET reser o P Dl Ou mn g l AAAA 75370003 Figure 3 Reset button 7537_en_00 www phoenixpowersupply co uk PHOENIX CONTACT 12 IL EIP BK DI8 DO4 2TX PAC 7 Connecting Ethernet the Supply Actuators and Sensors 7 1 Connecting Ethernet RJ45 Pint TD i TD i RD res res RD res res Figure 4 Pin assignment of the 8 pos RJ45 female 7 2 Connecting the Supply Actuators and Sensors PWR 01 11 12 1 1 Alfa 2 1 1135 21 113521 DA a E 12 22 32 42 12 kml 2 2 12100 22 12100 22 32 100 4 2 1 3 4 2 3 1 3153 23 13188123 33 19 8 4 3 O 1 4 hifas 2 4 14 18 2 4 1 46 6l 2 4 3 444 4 4 1 2 3 4 Figure 5 75370008 Terminal point assignment of the Inline connectors Terminal Point Assignment of the Power Connector connector 1 PWR Connect Ethernet to the bus coupler via an 8 pos RJ45 Terminal Assignment Terminal Assignment connector For the pin assignment please refer to the Points
31. or device configuration not complete or faulty Device in standby mode Flashing red Recoverable error Flashing red Selftest green OFF No supply voltage NS Green Network Network status ied Pa Green ON Module is online and has established a connection Red ON Error preventing communication with the network e g bus offline or double MAC ID Flashing green Device online connections not established Device has finished the double MAC ID test but has not established connections to other nodes Flashing red One or more connections in timeout state Flashing red Selftest green OFF Device not online Device has not yet finished the double MAC ID test Device has no IP address or is not supplied with voltage S1 Green Boot ON IP parameters received from BootP DHCP server AA Flashing BootP request responses in process OFF Stored IP parameters are used 7537_en_00 PHOENIX CONTACT 11 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC LED Color Meaning State Description of the LED States 01 D Green Diagnos ON Data transmission within the station active ue Flashing Data transmission within the station not active E Red Error ON Short circuit overload of outputs OFF No short circuit overload of outputs 1 4 Yellow 01 04 ON Outputs active OFF Outputs not active 11 12 1 8 Yellow 11 18 ON Inputs active OFF Inputs not active 6 Reset Button The reset button is
32. s Zack marker strip to label the terminals Labeling field covering one connector Labeling field covering four connectors Insert strips for IB IL FIELD 2 perforated can be labeled using a laser printer marker pen or CMS system 72 sheets Insert strips for IB IL FIELD 8 perforated can be labeled using a laser printer marker pen or CMS system 15 sheets DIN EN 50022 DIN rail 2 meters End clamp can be snapped on without tools End clamp can be fixed using screws Additional System Components Description Double sheathed Ethernet cable Flexible Ethernet cable Media converter 660 nm Voltage supplies Tools Description Assembly tool for RJ45 connector Screwdriver according to DIN 5264 blade width 3 5 mm Software Description BootP IP Addressing Tool Documentation Description Inline Bus Coupler for Ethernet IP With Eight Digital Inputs and Four Digital Outputs user manual I O Modules at Bus Couplers application note Automation Terminals of the Inline Product Range user manual Ordering Data Type IL EIP BK DI8 DO4 2TX PAC Type IL BKDIO PLSET FL PLUG RJ45 GR 2 FL PLUG RJ45 GN 2 CP MSTB ZB 6 see CLIPLINE catalog ZB 12 see CLIPLINE catalog IBIL FIELD 2 IBIL FIELD 8 ESL 62X10 ESL 62X46 NS 35 7 5 PERFORATED NS 35 7 5 UNPERFORATED CLIPFIX 35 5 E UK Type FL CAT5 HEAVY FL CAT5 FLEX FL MC 10BASE T FO POF QUINT PS see INTERFACE catalog Type FL CRIMPTOOL SZF 1 0 6
33. tions Objects CIP Class Services The IL EIP BK DI8 DO4 2TX PAC supports the following class services and instance services 9 2 Starting mhe Pirmwara Service Code Service Name By default upon delivery the dec hex IL EIP BK DI8 DO4 2TX PAC bus coupler has no 01 01 Get_Attribute_All valid JE parameters 02 02 Set_Attribute_All Once you have connected the power to the bus coupler the 05 05 Reset i i llowi th oe is started The following sequence appears on the 14 0E Get Attribute Single 16 10 Set_Attribute_Single Display Meaning BO flashing Starting Boot loader Transmitting BootP requests BO on Extracting firmware BO off Starting firmware RY flashing Firmware ready to operate 7537_en_00 PHOENIX CONTACT 15 www phoenixpowersupply co uk IL EIP BK DI8 DO4 2TX PAC 11 Operating Directives for the System 11 1 Repeat Packet Interval RPI Settings Configurations requiring RPI rates below 10 ms should first be tested for correct operation Configurations requiring PCP modules should use RPI settings of at least 20 ms Settings below 20 ms should first be tested 11 2 Maximum Connection The module firmware supports up to 128 connections in total any mixture of implicit and explicit Special features of the application such as CPU load data update frequency RPI parameter and scanned I O quantity have an effect on the maximum number of connections A lower number of conne
34. tware Update on Next Reboot field Software Update TFTP Server IP Address TRIP 172 16 40 201 Downloadable File Name 2897758 fw Software Update on Next C Enable Disable Reboot A Firmware Update was not initiated before the last restart if the software update status is set to enable the IL EIP BK DI8 DO4 will ty to load new software within the next reboot Press the apply button to change the software update status The settings will take effect after the next reboot of the IL EIP BK DI8 DOA Enter password Apply Apply and Reboot TFTP Update Status Software Update via FTP on Next Reboot if the software update status is set to enable the IL EIP BK DI8 DO4 will ty to load new software after reboot Press the apply and reboot button to change the software update status and start seboot of the IL EIP BK O18 DO4 Apply and Reboot Software Update menu C Enable Disable Enter password Figure 10 a If BootP is set to Enable and a reply with values for TFTP Server IP Address and Downloadable File Name is received on a restart these values overwrite the entries made in WBM The received values are displayed in WBM after the restart In the event of an error during Flash programming e g voltage interrupt the bus coupler can only be restarted by repeating the update The bus coupler starts the update automatically after a restart