        Herpstat Humidity User`s Manual
         Contents
1.  Humidity     2  Attach the Herpstat Humidity power plug to a standard wall outlet     3  Attach humidity device to any of the three outlets on the Herpstat Humidity  These devices may  include room humidifiers  foggers  or misting pumps  If using the device in Dehumidfy mode only  attach 120vac fans  Do not attempt to connect a room Dehumidifier  Do not exceed 500 watts   Herpstat Humidity controller and AC cords should be kept dry and away from water     Configure Menu  Adjustments  Display Type  Function  Mode  Active  Start  End  SetClock  Calibrate    When first powered on the Herpstat Humidity will display the probe status  To enter the Configure Menu press  the   Menu button  this menu only is available from the probe status screen  Use the   Display button to  navigate to it if necessary   The display will show two options       Setup    Config    Press the   button to enter the Configure Menu  While in the Configure Menu the Herpstat Humidity will toggle  to the next option after 5 seconds of inactivity and will return to normal operation once all options have been  displayed  While in the Configure Menu the output is disabled     Device Type  Options  Misting Fogger Humidity Dehumidify  Selects the type of control the Herpstat Humidity will use     Misting and Fogger have the same functionality  These will use a interval duration type control which will wait  for the triggered time and then check the humidity level  If the humidity is lower than your set range it wi
2.  hold  the PLUS button which will activate the humidity device for 60 second  Pressing the plus button again during  this will cancel the test     Next Cycle Time  Displays the next time the humidity level will be checked and acted on     Next Cycle End Time  Displays the time the next cycle will end  This is the time it starts plus the duration of the cycle     Getting the most out of your Herpstat Humidity    When setting up a new environment allow a minimum of one hour for the enclosure to stabilize  Probe  placement may require experimentation to achieve proper humidity regulation     The Herpstat Humidity has a built in resettable fuse  In a overload or overheat condition the fuse will trip  To  reset the fuse unplug the Herpstat Humidity for 2 minutes and then reapply power     When handling misting pumps or other humidity devices always unplug the Herpstat Humidity from  the wall outlet first for safety     Getting Help    Questions or comments can be e mailed to   support herpstat com   To purchase accessories please visit us on the web at   http    www spyderrobotics com          1 Year Limited Warranty    Spyder Robotics warrants this product to be free from defects in workmanship and material for a period of one  year from the date of purchase by the original purchaser  The warranty period shall not extend beyond 3 years  from the date Spyder Robotics shipped the product  During this warranty period Spyder Robotics will repair or  replace  at its option  any compon
3. Spyder Robotics       Herpstat Humidity User   s Manual    Herpstat Humidity    Made in USA       www spyderrobotics com    Thank you for choosing the Herpstat Humidity controller  This product offers the following    Adjustable Humidity regulation from 10 90  RH  Sensor accuracy      2  RH  between 10 90  RH     24 hour or settable time period operation   Adjustable duration  on time  from 2 seconds to 30 minutes  Adjustable interval  time between sessions  from 3 minutes to 8 hours  Two optional scheduled times to turn on    High   Low humidity and temperature tracking helps monitor moisture system and enclosure  efficiency     Adjustable calibration allowing the user to digitally calibrate the sensor output to match other  equipment     All settings are retained in memory even if power is lost    Power Outage detection   tracking    Easy to read backlit LCD display    Removable sensor for easy replacement if necessary    Resettable fuse never requires replacement    Audible alarm system   Internal error detection shuts off output if sensor fails or is disconnected   500 Watt rating     1 year limited warranty    Hardware Installation  WARNING   FIRE OR ELECTRICAL SHOCK MAY RESULT FROM MISUSE  For INDOOR USE ONLY     1  Mount the Herpstat Humidity probe in the enclosure  KEEP SENSOR AWAY FROM DIRECT  CONTACT WITH WATER  Should the sensor become saturated let it air dry for a several hours   Insert the connector on the probe into the jack on the top left side of the Herpstat
4. ent parts that in its opinion prove to be defective  Replacement parts may be  new or serviceable used parts at Spyder Robotics option  of equal or better quality to those being replaced  This  warranty does not extend and shall not apply to products that have been subjected to misuse  neglect  accident   or improper installation     THIS LIMITED WARRANTY AND REMEDY ARE EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES  EXPRESSED OR IMPLIED  INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MECHANTABILITY  AND FITNESS FOR A PARTICULAR PURPOSE  IN NO EVENT SHALL SPYDER ROBOTICS BE LIABLE FOR LOST  PROFITS  LOSS OF GOODWILL  OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES     If you return your product to Spyder Robotics for warranty service  proof of purchase may be required  A  Return Material Authorization  RMA  number must be obtained prior to the return  Spyder Robotics is not  responsible for material returned without the RMA number clearly printed on the outside of the shipping  container  To request an RMA number  contact Spyder Robotics with the description of failure  serial number of  device  and date of purchase via e mail at returns spyderrobotics com  Products to be returned to Spyder  Robotics must be returned  shipping and insurance prepaid  by the original purchaser to the address below     Spyder Robotics  Attn  RMA    634 S  1  ST   Rochelle  IL 61068      2005 Spyder Robotics  http    www spyderrobotics com       manual HS401  6 23 08    
5. ive option is set to Period     End  This is the time you want the Herpstat Humidity to stop controlling the humidity  This setting is only available if  Active option is set to Period     Sched 1   Options  Enable Disable   Enable this option if you would like to force a scheduled on cycle  It will then allow you to set a time for that  event to happen  This can be useful if you would like a little extra humidity during a certain time or misting  session for drinking purposes  During this event the humidity device will be powered on regardless of your  humidity range or time period settings and will last the length of your set Duration     Sched 2   Options  Enable Disable   Enable this option if you would like to force a scheduled on cycle  It will then allow you to set a time for that  event to happen  This can be useful if you would like a little extra humidity during a certain time or misting  session for drinking purposes  During this event the humidity device will be powered on regardless of your  humidity range or time period settings and will last the length of your set Duration     Display Type  Options  Celsius  Fahrenheit  The default setting is to display temperature in Fahrenheit     SetClock  Adjusts the internal clock   s time     Calibrate  This option allows users to calibrate the Herpstat Humidity Use the   and   buttons to adjust the offset     Note  The Herpstat Humidity sensor is very accurate in its default setting  Modifications in this menu are not  t
6. ll  activate the humidity device until the end of your duration setting  Then it will wait the amount set by the  interval before activating again  Humidity is only checked at the beginning of the triggered cycle to determine if  it will activate the humidity device  Once the humidity device is powered on it will not turn off until the end of  your set duration or if the emergency stop option is used  You will need to watch and experiment with the  Interval   Duration times to match your enclosure and humidifying equipment     Setting the device type to Humidity will constantly monitor humidity and will activate the humidity device any  time the actual humidity drops below your set range  It will then shut the device off when the actual humidity  breaches your max humidity setting  This is used for room humidifiers or other humidity equipment that have a  slow humidity increase     Dehumidify is only to be used with fans to air out an enclosure  Do not attach a room dehumidifier to the  Herpstat Humidity     Active   Options  Always ON   Period   The default setting is for Always ON  When Set to Always ON the Herpstat Humidity will be free to  monitor adjust the RH all of the time  When set to Period it allows you to setup a time period that you want it  to run  This allows you to only run it during the day and off at night or other combinations     Start  This is the time you want the Herpstat Humidity to start controlling the humidity  This setting is only available if  Act
7. nd a half set this  option to 1h 30m     The Display    Options  Probe Status  Humidty and Temperature    High Low RH Level  High Low Temperature  Power Outage Monitor  Cycle Status and Internal Clock    Emergency Stop and Forced On Option   Next Cycle Time   Next Cycle End Time    Use the   button to toggle between displays  Use the   button to enter a menu or set options     Temperature Probe Status  amp  Power Output  Shows the current temperature and RH from the probe     High Low RH  Displays the highest and lowest humidity recorded  Pressing the   button will reset the  High   Low humidity to the current humidity value     High Low Temperature  Displays the highest and lowest temperature recorded  Pressing the   button will reset the  High   Low temperatures to the current temperature     Power Outage Monitor  Each time the Herpstat Humidity is powered on it increments this monitor  To reset the monitor to zero press  the   button     Cycle Status and Internal Clock   Displays if the Herpstat Humidity is currently in a time period that is regulating the humidity level  Active  means it is in a operational session  Inactive means the Herpstat Humidity is currently not monitoring or acting  on humidity changes  Also displays the current time     E Stop   Force ON   During a misting cycle when power is applied to the humidity device you can activate a Emergency Stop by  toggling to this screen and pressing and releasing the PLUS button  To test your setup you can press and
8. ypically necessary     Setup Menu  Adjustments  Max RH  Min RH  Duration  Interval    When first powered on the Herpstat Humidity will display the probe status  To enter the Setup Menu press the    button  this menu only is available from the probe status screen  Use the   Display button to navigate to it if  necessary   The display will show two options       Setup    Config    Press the   button again to enter the Setup Menu  While in the Setup Menu the Herpstat Humidity will toggle to  the next setting after 5 seconds of inactivity and will return to normal operation  While in the Setup Menu the  output is disabled     Max RH  This is the maximum acceptable humidity level desired  Default setting is 20   The humidity will need to  exceed this number before action is taken     Min RH  This is the minimum acceptable humidity level desired  Default setting is 10   The humidity will need to drop  below this number before action is taken     Duration  This is the length of time the output device will be enabled  This option is only available if the Device Type is  set to Misting or Fogger     For Example   If you have a misting system and want the pump to be turned on for 30 seconds when the timing cycle activates  then set the duration to 30s     Interval  This is the elapsed time between checks  This option is only available if the Device Type is set to Misting or  Fogger     For Example   If you have a misting system and you want the humidity level to be checked every hour a
    