Fuel Cell Technology ALCOSCAN AL4000 User`s Manual The Fuel

image

Contents

1. in the right place on the board B If you still have the error message replace the sensor 1 The machine is lugged in but there is no power a The power of the product was set at 110V or 220V by default You need to make sure the voltage is collect b Make sure that the line attached to the power adapter is connected correctly to the power socket on the bottom of the machine You inserted a coin but the machine does not work a Make sure you use the proper coin The machine only accepts the specified kind and others are returned b Select Coin number using the SW2 button and then make sure the number set on the display window is correct As explained above the machine will work only if you use this number of coins There is no buzzer sound The option for buzzer sound can be selected In the set up mode check the status of the set up as explained above You blow but the machine does not respond Check if the display window shows Sensor error If it does the machine may have a problem You need to take the action corresponding to the error number as previously explained After testing the machine does not go back to the waiting mode The machine displays the result value for about 10 seconds In order to go back to the measuring mode the alcohol blown into the machine must be eliminated completely The amount of alcohol increases the time required for this elimination to be competed but it normally d
2. 0 220 50 60 HZ 0 5A input Result reading Open the machine and you will see three buttons on the top of the electric circuit board Press two buttons labeled SW1 and SW2 at the same time hold them down for at least four seconds and then release them You can see this message To enter the set up mode This changes the status into the set up mode To go back to the previous mode repeat the above procedure The set up mode allows you to work the machine s maintenance It is possible to change functions only by pressing SW1 If you select the function please press SW2 1 Buzzer You can turn the buzzer sound on or off by using On or Off 2 Low Pass Level The default number can be set from 0 000 to 0 040 BAC 3 Hi Danger Level Being above the level entails you are over the legal limit permitted and that you must not drive The default number can be set from 0 050 to 0 100 BAC Go to To enter the set up mode again if you finish setting the function and then select EXIT The software product is easy to maintain and its operating environment can be changed without any special skills It automatically checks and adjusts the accuracy rate of measurement SW1 Total Count SW2 Set the coin number SW3 Test ejeje 1 If you want to check the total amount of tests press SW1 and the display window will show the test Press SW1 during 2 seconds and the count will be r
3. Fuel Cell Technology ALCOSCAN AL4000 User s Manual The Fuel cell sensor type Alcoscan AL4000 is the coin operated breathalyzer It is used in restaurants to prevent alcohol related traffic accidents by customers The instructions are displayed on LCD the lamp will be lit to show warning depending on the result making the device easier and more convenient to use ALCOHOL ANALYZER LCD display 5 Coin Slot Good Light Bulls eye Warning Light Danger Light Straw outlet Bulls eye This is where the customer places the straw to blow into the machine The Sampling time is 3 seconds Coin Slot Located on the right side of the machine it accepts only the coin denomination specified Others are returned Straw outlet This is where the straws emerge from the machine The straws should be used to perform the test LCD display The instructions are displayed on LCD 1 KNOW YOUR LIMIT CHECK YOUR ALCOHOL LEVEL INSERT COIN S AND TAKE A STRAW 2 WARMING UP PLEASE WATT gt P gt gt P gt gt gt p gt 3 BLOW STEADILY UNTIL TONE ENDS SAMPLING 4 SAMPLING IS COMPLETED ANALYZING If you stop blowing or you do not breathe strongly enough Flow Error will be displayed on LCD The device does not sense a proper breath sample please wait and try again and the machine will return to the waiting mode This process will continue until you finally obtain a correct r
4. eset to 0 automatically returning to normal operation mode Wait a few seconds after testing 2 When you adjust the number of coins for each test press SW2 during 2 seconds The display window will show set the coin number then press SW2 again It will allow from O to 10 coins per test If number 2 is entered that means two coins are required The default number was set to 1 If you have trouble with the sensors you should only replace them with those provided by the manufacturer Please refer to the following for replacement issues Turn the power off Very Important Open the rear door of AL4000 and unscrew Pull out the sensor board above the arrow direction 1 2 3 4 Plug out the connector and exchange the new sensor board 5 Plug in connector push the sensor board and turn 4 screws tightly 6 Turn on the power and then perform the accuracy adjustment 7 The replacement concludes 1 Flow error If you stop blowing or you do not breathe strongly enough Flow Error will be displayed on LCD Please wait and try again and the machine will return to the waiting mode 2 Coin error A If an inadequate coin is inserted and caught in the slot you will see this message Push the button below the coin slot or check the coin slot form inside B If the coin is full in a coin container you will see this message Please empty the coin container 3 Sensor error A Check if the alcohol sensor is
5. esult 5 Display the result When the measurement is complete the blood alcohol concentration will appear on the LCD display Then the guide will indicate whether or not you can drive aided by lamplights The message for each level is Good Very little or no alcohol has been detected Don t drink and drive Warning A moderate amount of alcohol has been detected Don t drink and drive 9 Danger A high level of alcohol has been detected Don t drink and drive 1 During testing any alcohol traces left in your mouth will increase the value of the blood alcohol concentration level Remove these traces before testing Highest accuracy is achieved 30 minutes after drinking 2 When you exhale through the straw some unintentional salivation may affect the built in equipment However please be aware that placing any other liquids or materials into the straw may cause the sensor to malfunction 3 Cigarette smoking may also increase the blood alcohol concentration value Allow one minute after smoking before testing 0 000 to 5 000 o or Indication of B A C 0 000 to 2 500 mg or 0 000 to 0 500 BAC within 6 seconds at 0 10 BAC 0 005 BAC at 0 100 BAC Operation 0 to 40 C Ambient conditions Storage O to 50 C Display LCD Module Good Less than 0 02 BAC 0 00 0 20 o or 0 00 0 10mg l Warning 0 02 0 05 BAC 0 20 0 50 or 0 10 0 20mg l Danger More than 0 05 BAC 0 50 or 0 25mg l AC 11
6. oes not exceed a minute If it takes more than one minute the sensor may be malfunctioning You should contact customer services in this case The manufacturer warrants the product to be free from defects in workmanship or material excluding calibration under normal use for six 6 months from the date of purchase The manufacturer s obligation under this warranty is limited to replacing adjusting or repairing the unit if returned along with proof of purchase This warranty is void if the unit has been tampered with or maliciously damaged For recalibration and technical support please contact us at www alkotesteri net