1. 6 Drain Pipe 7 Gas Pipe 8 Lipuid Pipe 9 Big Handle ry AU a 10 Front Board ES WIRELESS REMOTE CONTROLLER Operation and Display View Note This remote controller is universal and can be used for multi functional air conditioning If the button on the remote controller with the function which the air conditioner doesn t have is pressed the unit remains in its original operating mode eso Ooo 8 6860 Oo Table Operation instruction of wireless remote controller Function Description Signal l Signal transmitter transmitter ON OFF Press this button and the unit will be turned on press it once more and the unit will be turned off When turning but
2. Table Instruction to buttons of wired controller Function selection and canceling 1 Enter Cancel Press it for 5s to view the ambient temperature press Mode button to select viewing outdoor ambient temperature or indoor ambient temperature Running temperature setting range of indoor unit 16 30 C 2 Timer setting range 0 5 24hr Setting of air function level Setting of energy saving temperature Setting of cleaning class Setting of high medium high medium medium low low auto fan speed Setting of auto cooling heating fan dry mode of indoor unit Switch over among these functions of swing air sleep health Demand out turbo save Function e heater X fan clean quiet 8 On Off Turn on off indoor unit state after power failure and then power recovery If not indoor unit is defaulted to be off 5 7 4 Mode and Memory function 2A l a after power recovery Ex factory setting of memory function is on 2A Upon startup of the unit without malfunction or under off state of the unit press A and V and Lock buttons at the same time for 5s to enter lock state In this case any other buttons won t 6V respond when pressing Repress A and YW buttons for 5s to quit lock state 4 Mode Enquiry and setting and of address of wired 5 Function controller Press Mode and A buttons at the same time for 5s under off state of the unit to enter cancel memory function If memory function is set indoor unit will resume original sett
3. press it for 5s to view the ambient temperature In this case timer zone displays ambient temperature type 01 or 02 Ambient temperature zone displays the corresponding temperature of that type 01 stands for outdoor ambient temperature and 02 stands for the indoor ambient temperature after compensation Press Mode button to switch between 01 and 02 Pressing other buttons except Mode button or receiving remote control signal will exit enquiry state If there is no operation within 20s will also exit enquiry state Note 1 Ifthe unit is not connected to outdoor ambient temperature sensor display of outdoor ambient temperature will be shielding after energizing for 12hr 2 If there is malfunction of outdoor ambient temperature sensor display of outdoor ambient temperature will be shielding after energizing for 12hr Enquiry of Historical Malfunction Under off or on state of the unit continuously press Function and VW buttons for 5s to view historical malfunction In enquiry state set temperature displaying zone displays 00 Press A and VY buttons to view the 5 malfunctions happened recently The timer displaying position displays the detailed error code The 5 displayed malfunction is the last malfunction Debugging Function Under off state of the unit press Function and Timer buttons at the same time for 5s to go to the debugging menu Press Mode button to adjust the setting items and press A or V button to set the actual v
4. adjust on filter clean reminder function setting of filter clean reminder timer zone to display 00 function Enter Cancel 6 Function y Timer On Off Press Enter Cancel button to cancel filter clean reminder function Figure Setting of filter clean reminder function When setting the filter clean reminder function timer zone will display 2 digits of which the former indicates the pollution degree of operating place and the latter indicates the accumulated operating time of indoor unit There are 4 types of situations 1 Clean Reminder is off Timer zone shows 00 2 Slight pollution the former digit in timer zone shows 1 while the latter one shows 0 which indicates the accumulated operating time is 5500hr Each time the latter digit increases 1 the accumulated operating time increases 500hr When it reaches 9 it means the accumulated operating time is 10000hr 3 Medium pollution the former digit in timer zone shows 2 while the latter one shows 0 which indicates the accumulated operating time is 1400hr Each time the latter digit increases 1 the accumulated operating time increases 400hr When it reaches 9 it means the accumulated operating time is 5000hr 4 Heavy pollution the former digit in timer zone shows 3 while the latter one shows 0 which indicates the accumulated operating time is 100hr Each time the latter digit increases 1 the accumulated operating time increases 100hr When it rea
5. be increased or decreased 10 minutes every 0 5 seconds After that another press on the CLOCK button accepts the setting 12 00 is the default when the wireless remote controller is energized When TIMER ON is activated ON will blink while the symbol will disappear Within 5 seconds it is allowed to set the ON time by pressing the button Each press will make the time increase or decrease one minute Besides the time can also be set by pressing the button constantly that is in the early 2 5 seconds the time will increase decrease quickly per single minute and in the late 2 5 the time will increase decrease per ten minutes After the desired time value is set press TIENE ON again to conform the setting within five seconds After that another press on TIMER ON will cancel the setting Prior to this setting the clock shall be set to the actual time Pressing this button can activate or deactivate the X FAN function In Cool or Dry mode by pressing this button if 9O is displayed it indicates the X FAN function is activated By repressing this button if io disappears it indicates the X FAN function is deactivated After energization X FAN OFF is defaulted If the unit is turned off X FAN can be deactivated but can t be activated By pressing this button it is allowed to select displaying the indoor setting temperature or the indoor ambient temperature Indoor setting temperature is default after the indoor unit is ene
6. button to adjust to 06 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 Mode 1 LCD displays 00 2 Mode 2 LCD displays 01 Note 1 Mode 1 Compressor electric heating belt starts when outdoor ambient temperature is below 35 C and stops when outdoor ambient temperature is above 37 C When outdoor ambient temperature is within 35 C 37 C the belt will Keep its previous operation state 2 Mode 1 Compressor electric heating belt starts when outdoor ambient temperature is below 2 C and stops when outdoor ambient temperature is above 0 C When outdoor ambient temperature is within 2 C 0 C the belt will keep its previous operation state Selecting low power consumption mode Under debugging state press Mode button to adjust to 07 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 With low power consumption mode LCD displays 00 2 Without low power consumption mode LCD displays 01 Selecting door control function Under debugging state press Mode button to adjust to 08 in temperature displaying zone Timer zone displays setting state and press A or W button to adjust There are 2 selections 1 Without door control function LCD displays 00 2 With door control function LCD displays 01 Selecting human sensitive function Under debugging stat
7. D displays 01 2 Not displayed LCD displays 02 It is defaulted to be not displayed for export unit and be displayed for domestic unit Setting refrigerant lacking protection function Under debugging state press Mode button to adjust to 04 in temperature displaying zone Timer zone displays setting state and press A or W button to adjust There are 2 selections 1 With refrigerant lacking protection function LCD displays 01 2 Without refrigerant lacking protection function LCD displays 02 Selecting blowing residual heating of indoor unit Under debugging state press Mode button to adjust to 05 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 Mode 1 LCD displays 00 2 Mode 2 LCD displays 01 Note Blowing residual heating of indoor unit Mode 1 Unit stops when reaching temperature point and indoor fan motor does not stop in cooling mode after unit stops when reaching temperature point in heating mode duct type unit and floor ceiling unit blow residual heat for 60s and then stop indoor unit while cassette type unit always operates in low fan speed and blows residual heat for 60s when there is malfunction Mode 2 After unit stops when reaching temperature point the indoor fan motor stops operation with a 10s delay no matter in cooling mode or in heating mode Mode selecting of compressor electric heating belt Under debugging state press Mode
8. USER S MANUAL SINCLAIR AIR CONDITIONING Original instructions Safety Precautions This mark indicates procedures which if improperly performed might lead to the WARNING S death or serious injury of the user This mark indicates procedures which if improperly performed might possibly CAUTION result in personal harm to the user or damage to property 1 For operating the air conditioner pleasantly install it as outlined in this installation manual 2 Connect the indoor unit and outdoor unit with the room air conditioner piping and cord available from our standard parts This installation manual describes the correct connections using the installation set available from our standard parts 3 Installation work must be performed in accordance with national wiring standards by authorized personnel only 4 If refrigerant leaks while work is being carried out ventilate the area If the refrigerant comes in contact with a flame it produces toxic gas 5 Do not power on until all installation work is complete 6 During installation make sure that the refrigerant pipe is attached firmly before you run the compressor Do not operate the compressor under the condition of refrigerant piping not attached properly with 2 way or 3 way valve open This may cause abnormal pressure in the refrigeration cycle that leads to breakage and even injury 7 During the pump down operation make sure that the compress
9. al authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic www hnepa CcZ Toll free info line 420 800 100 285
10. alue Setting ambient temperature sensor dual ambient temperature sensors function Under debugging state press Mode button to adjust to OO in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 3 selections 1 The ambient temperature at air return is set as indoor ambient temperature timer zone displays 01 2 The temperature at wired controller is set as indoor ambient temperature timer zone displays 02 3 Select the temperature sensor at air return in cooling dry and fan mode select the temperature sensor at wired controller in heating and auto mode timer zone displays 03 Selecting three speeds in high speed and three speeds in low speed of indoor fan motor Under debugging state press Mode button to adjust to 01 in temperature displaying zone Timer zone displays setting state and press A or W button to adjust There are 2 selections 1 Three speeds in low speed LCD displays 01 2 Three speeds in high speed LCD displays 02 Three speeds in low speed include high medium and low speeds three speeds in high speed include super high high and medium speed Note For this series this function is invalid Displaying setting of freeze protection error code Under debugging state press Mode button to adjust to 02 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 Displayed LC
11. ange Table 12 Indoor Side Outdoor Side Test Condition C WB C C Nominal Heating EE E e a Rates cooing 2 s ow Temp cooing 2 s raana 27 SiS iow Temp Heatro al mw The design of this unit conforms to the requirements of EN14511 standard 2 The air volume is measured at the relevant standard external static pressure 3 Cooling heating capacity stated above is measured under nominal working conditions corresponding to standard external static pressure The parameters are subject to change with the improvement of products in which case the values on nameplate shall prevail 4 In this table there are two outside DB values under the low temp cooling conditions and the one in the brackets is for the unit which can operate at extreme low temperature Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a place for take back where it is collected free of charge By correct disposal of the product you can help to preserve valuable natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from loc
12. ce If slave wired controller is set the corresponding icon will be displayed Figure Enquiry and setting of master slave wired controller s address OPERATION INSTRUCTION OF SPECIAL FUNCTIONS Setting of Filter Clean Reminder Function When unit is on press Function button to switch to filter clean reminder function The icon will blink and then enter setting of filter clean reminder function Timer zone displays the set pollution level and you can press A or Y button to adjust the level Then press Enter Cancel button to turn on this function When filter clean reminder function is turned on press Function button to switch to filter clean reminder function The icon will blink and press A or V button to adjust timer zone to display 00 Then press Enter Cancel button to cancel this function Setting of filter clean reminder function is shown as Figure below AUTO Enter Cancel A Enter Cancel Function vy Timer On Off aon y Timer On Off Function Timer On Off Unit is on and filter clean reminder Press Function button to switch to Press A or V button to set pollution function is not turned on setting of filter clean reminder level function Lb Enter Cancel Enter Cancel A Enter Cance A 6 Function la Timer On Off hen y Timer On Off Function y Timer On Off Press Enter Cancel button to turn Press Function button to switch to 00 Press A or V button to
13. ceman to check and repair the unit Routine Maintenance Only a qualified service person is allowed to perform maintenance Before accessing to terminal devices all power supply circuits must be disconnected Do not use water or air of 50 C or higher for cleaning air filters and outside panels Note Do not operate the air conditioner with the filter uninstalled otherwise dust would come into the unit Do not remove the air filter except for cleaning Unnecessary handling may damage the filter Do not clean the unit with gasolene benzene thinner polishing powder or liquid insecticide Installation of Controllers Refer to the Installation Manual of the controller for more details Test Running Operation and Testing 1 The meaning of error codes as shown below Table 11 1 E1 Compressor high pressure protection a a a ae ee Compressor low pressure protection refrigerant lack 8 ww 4 E4 Compressor high discharge temperature protection Pp 58 S Communicationerror o 6 EBL indorfanmotoreror Oor o e O o Fwar protection 8 Fo indoorambienttemperature sensoreror o f Evaporator temperature sensor eror 10 F2 Condenser temperature sensor error tt F3 Outdoor ambient temperature sensor error 12 F4 Discharge temperature sensor error 13 F5 Temperature sensor error of wired controller oo 5 capactycodeero i O 6 EE outdoormemoych
14. ches 9 it means the accumulated operating time is 1000hr The detailed pollution level and the corresponding time is as shown in Table below Table Pollution level and corresponding time l Accumulated Accumulated l Accumulated Pollution level e Pollution level ai Pollution level operating time hour operating time hour operating time hour 5500 1400 6000 1800 6500 2200 7000 2600 5800085 ao ao 0 lf filter clean reminder function is turned on the icon will be on 1 If cleaning time is not reached no mater the setting is changed or not the accumulated operating time won t be recalculated when pressing Enter Cancel button 2 If cleaning time is reached in unit on or off state will blink every 0 5s for reminder Press Function button to switch to icon and press A and VY button to adjust the level Then press Enter Cancel button so the accumulated operating time won t be cleared If the adjusted level is higher than the present accumulated operating time the icon won t blink any more if the adjusted level is lower than the present accumulated operating time the icon will go on blinking 3 The only way to cancel filter clean reminder function is to press Function button to switch to filter clean reminder function The icon will blink and press A or button to adjust timer zone to display 00 In this case the accumulated operating time will be cleared Low Temperature Drying Function Under dry mode and when se
15. e press Mode button to adjust to 09 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 Without human sensitive function LCD displays 00 2 With human sensitive function LCD displays 00 Selecting long distance monitoring or centralized controller Under debugging state press Mode button to adjust to 10 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 2 selections 1 Centralized controller LCD displays 00 2 Long distance monitoring LCD displays 01 Selecting fan mode of indoor fan motor Under debugging state press Mode button to adjust to 11 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 5 selections 1 P3 LCD displays 03 2 P4 LCD displays 04 3 P5 LCD displays 05 4 P6 LCD displays 06 5 P7 LCD displays 07 Note You can select P03 P04 P05 PO6 PO7 in fan mode of indoor fan motor which means different fan mode combinations are corresponding to different static pressure Ex factory defaulted mode is P05 You can set the mode through wired controller S01 S02 SO3 12 S13 means the rotation speed of indoor unit is from low to high Table Combination relationship of P03 P04 P0O5 P06 PO7 tati bana Super high Hiahkstesd Medium Medium Medium ELOT Quiet Quiet Quiet a speed A hi
16. erant lacking protection refrigerant recycling mode Compressor high discharge temperature protection Communication malfunction Malfunction of condenser temperature sensor Malfunction of outdoor ambient temperature sensor Malfunction of discharge temperature sensor I I Drive desynchronizing protection S T SS Ca o CMfuntion of humicty sensor el sara pis SSS Compressor phase protecion O O O a a pwemem Ftp Moas of indoor unit and outdoor unit do nat match with each other ur Direction changing malfunction of way vave pl pbvrepcm oem e Communication malfunction between main control and drive O P Oo P o P O A _ o PC Pd I PE o PL T pp omyomptoee pee O Meucon of outdoor drive memory chip When there is a malfunction during operation error will be displayed on the temperature displaying zone of LCD When several malfunctions occur at the same time these error code will be displayed circularly When there is a malfunction please turn off the unit and ask the professional for maintenance For example E1 means high pressure protection during operation Hc L1 Lc Ld LF Lp i U7 Po Pr Malfunction of drive module sensor High temperature protection of drive module PA PC PE PL PH i U Enter Cancel A Function y Timer On Off Figure 2 6 1 Troubleshooting and Maintenance Troubleshooting If your air conditioning unit suffers from abnormal operation or failure please first check t
17. gh speed speed low speed j R1 speed R2 speed R13 speed Selecting compensation of temperature sensor at air return Under debugging state press Mode button to adjust to 12 in temperature displaying zone Timer zone displays setting state and press A or V button to adjust There are 16 selections 1 Compensate 0 C LCD displays 00 2 Compensate 1 C LCD displays 01 3 Compensate 2 C LCD displays 02 4 Compensate 3 C LCD displays 03 5 Compensate 4 C LCD displays 04 6 Compensate 5 C LCD displays 05 7 Compensate 6 C LCD displays 06 8 Compensate 7 C LCD displays 07 9 Compensate 8 C LCD displays 08 10 Compensate 9 C LCD displays 09 11 Compensate 10 C LCD displays 10 12 Compensate 11 C LCD displays 11 13 Compensate 12 C LCD displays 12 14 Compensate 13 C LCD displays 13 15 Compensate 14 C LCD displays 14 16 Compensate 15 C LCD displays 15 Note Indoor ambient temperature compensation can be set through wired controller E g If 02 is selected it indicates the compensation temperature is 2 C If the indoor ambient temperature detected by the temperature sensor at air return is 29 C the ambient temperature after compensation is 29 C 2 C 27 C After finishing setting press Enter Cancel button to save and exit setting After entering this interface the system will exit this menu if there is no operation on the button within 20s Normal off state interface wi
18. he following points before repair Failure Possible Reasons The power supply is not connected Electrical leakage of air conditioning unit causes tripping of the leakage The unit cannot be started switch The operating keys are locked The control loop has failure There is obstacle in front of the condenser The unit operates for a The control loop is abnormal while and then stops Cooling operation is selected when the outdoor ambient temperature is above 48 C The air filter is dirty or blocked There is heat source or too many people inside the room The door or window is open Poor cooling effect There is obstacle at the air intake or outlet The set temperature is too high There is refrigerant leakage The performance of room temperature sensor becomes worse The air filter is dirty or blocked The door or window is not firmly closed The set room temperature is too low Poor heating effect There is refrigerant leakage The outdoor ambient temperature is lower than 5 C Control loop is abnormal After carrying out the check of the above items and taking relevant measures to solve the problems found but the air conditioning unit still does not function well please stop the operation of the unit immediately and contact the local service agency designated by Sinclair Only ask professional servi
19. ing Under off state of the unit press Mode and Function buttons at the same time for 5s to set the address More details please refer to project debugging Setting of project parameters More details please refer to the Notes 5 Function and 7 Timer Under off state of the unit press Function and Timer buttons at the same time for 5s to go to the debugging menu Press Mode button to adjust the setting items and press A or Y buttons to set the actual value Switch between Fahrenheit and Centigrade Under off state of the unit press Mode and WV buttons at the same time for 5s to switch between Fahrenheit and Centigrade Continuously press Function and W buttons for 5s to view historical malfunction Then Viewing historical press A and VY buttons to adjust displayed contents The timer displaying position malfunction displays the sequence of malfunction and the detailed error code The 5 displayed malfunction is the last malfunction 5 Function and 6V 1 Enter Cancel Under off state of the unit press Enter Cancel and Mode buttons at the same time for Setting of master and i l and 3 5s to set master and slave wired controller Press A or W button to adjust More details slave wired controller 4 Mode please refer to project debugging Notes The following functions can be set through Function and Timer buttons setting of ambient temperature sensor selecting three speeds in high speed and three speeds in low s
20. ipero 7 TPR Eleoricboxsensoreror J O 18 H3 Compressor overload protection gm oem Co TH SPM protection pat LC fan motorerror P22 H Drive desynchronizing protecion Ca we pepoedim O C o CAtivation failure a Compressor phase sequence protection P27 E Compressor staling protection Oa oo OO powerpoecm 29 lp Indoor and outdoor mismatch u7 4 way vake direction changing protecion Ca o o O o Drveresetprotecion o ps2 s Overcurrent protection P33 Pe Communication error between main control and drive 34 iP S Crive module sensorerror P8 Drive module over temperature protection 3 P9 Zero passage protection AC current protection PT T Pd Sensor connecting protection 40 PE Temperature arf protection 41 PL Bus low voltage protection 42 PH Bus high vottage protection Ca pu o Caeoperor tvotageabmomay Dememoyciperr Note When the unit is connected with the wired controller the error code will be simultaneously shown on it 2 Instructions to the Error aaa roel on the Panel of the Duct Type Unit Power Running Indicating lamp Cooling indicating lamp ls Heating indicating lamp Dehumidification oe r a Receiver indicating lamp p A Wz 88 display Cool button Htat button at ba Fig 47 6 2 Working Temperature R
21. is selected the wired controller will work when the room card is inserted and stop working when the room card is not inserted when human sensitive function is selected the wired controller will work when it senses there is somebody in the room and stop working when it senses there is nobody in the room When the door control function senses the room card is not inserted or human sensitive function senses there is nobody in the room the wired controller will display y icon Note 1 In long distance monitoring or centralized control no matter the room card is inserted or not the ON OFF of unit can be controlled If long distance monitoring or centralized control information is received when the room card is not inserted py icon is cleared When the card is reinserted door control function is judged to be turned on If long distance monitoring or centralized control information is received when the room card is inserted it will keep the original status 2 The unit can not be controlled by buttons when the card is not inserted 8 When door control function and human sensitive function have been set at the same time it is defaulted that door control function is valid and human sensitive function is invalid Switch between Fahrenheit and Centigrade Under off state of the unit press Mode and W buttons at the same time for 5s to switch between Fahrenheit and Centigrade Enquiry of Ambient Temperature Under off or on state of the unit
22. ll be displayed and present setting will not be saved INSTALLATION OF WIRED CONTROLLER Standard Accessories Table Standard Accessories of Wired Controller Socket base box installed in the wall No 1 in Figure 2 5 1 Base plate of wired controller No 2 in Figure 2 5 1 Screw M4x25 No 3 in Figure 2 5 1 Panel of wired controller No 4 in Figure 2 5 1 k N SA SS SS SS i Y NY 7 Figure 2 5 1 Installation Position and Requirement 1 Prohibit installing the wired controller at the misty place or the place with direct sunlight 2 Prohibit installing the wired controller at the place near high temperature objects or water splashing places 3 Prohibit installing the wired controller at the place where faces forward to the window to avoid interference of another remote controller from neighborhood 4 Cut off the power of heavy current wire in the installation hole of the wall All power should be cut off during installation 5 In order to avoid abnormal operation due to electromagnetic interference etc pay attention to the following notes during connecting wires 1 Make sure the tie in interface of communication wire is correct otherwise it may lead to communication malfunction 2 The signal wires and communication wires of wired controller should be separated from power cord and connection wire between indoor unit and outdoor unit 3 If the air conditioner is installed at the
23. lt FAN i Eaa aaa ow spee button _aa Middle speed al High speed Note Under the DRY mode the fan will be kept running at the low speed and the fan speed isn t adjustable CLOCK button SWING UP DOWN button TIMER ON button X FAN button TEMP button TURBO button SLEEP button D LIGHT button Press this button to set up the swing angle which circularly changes as below gt I gt J gt gt A S OFF lt f gt l 3l When the guide louver starts to swing up and down if SWING functions is canceled the air guide louver will stop and remains at the current position esi indicates the guide louver swings up and down among those five directions Simplified SWING function applicable for some Fan Coil Units When the wireless remote controller is energized initially with the unit under the OFF status it should be set by pressing the button and the SWING button simultaneously with the symbol blinking twice Then after the unit is turned on this function can be activated by pressing the SWING button 7 with the displayed symbol SI indicating swing function is on and without this displayed symbol indicating swing function is off By pressing this button the clock is allowed to be set with D blinking and then press the button to adjust the clock within 5 seconds If the button is pressed down constantly for more than 2 seconds the clock setting will
24. o off the icon Pen will be disappeared and the indicating light in the displayer will be off WIRED CONTROLLER Display View AUTO TURBO Cl CO JE F oT HOUR E E FOO C 986 ONOFF Enter Cancel Function y Timer On Off Figure 2 3 1 Appearance of wired controller 1 2 3 4 5 6 7 8 9 1011 12 13 AUTO TURBO 14 15 16 1718 19 20 21 22232425 26 27 Figure 2 3 2 LCD display of wired controller Table Instruction to LCD Display Z O Introduction Left and right swing function Up and down swing function Air exchange function Sleep function Auto mode COOL mode DRY mode FAN mode HEAT mode OA Health function l Demand function O Vacation function CD Status display of master and slave wired controller Shield function CD T m m The button operation temperature setting On Off operation Mode setting and Save setting are disabled Cn Fan speed Memory function _ 6 The unit will resume the original setting state after power recovery _ Turbo function Energy saving function CO Ambient setting temperature N Electric heater N Blow function 22 Defrosting function 23 Filter cleaning 24 Timer Setting Keycard control Detected status sensed by human body Quiet function Lock function N N N N O Cn Operation View Silk Screen of Buttons Enter Cancel Instruction to Function of Buttons
25. or is turned off before you remove the refrigerant piping Do not remove the connection pipe while the compressor is in operation with 2 way or 3 way valve open This may cause abnormal pressure in the refrigerant cycle that leads to breakage and even injury 8 When installing and relocating the air conditioner do not mix gases other than the specified refrigerant R410A to enter the refrigerant cycle If air or other gas enters the refrigerant cycle the pressure inside the cycle will rise to an abnormally high value and cause breakage injury etc 9 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 10 Children should be supervised to ensure that they do not play with the appliance 11 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Outline of the Unit and Main Parts Indoor Air outlet o_o power Cord g Electric Box Q 3 Wired controller Outdoor Wireless Controller Air inlet 5 Binding tape UCU nt a D
26. peed of indoor fan motor display setting of freeze protection error code setting of cold air prevention and hot air hot prevention function setting of refrigerant lacking protection function selecting of blowing residual heat of indoor unit selecting of compressor electric heater mode selecting of low power consumption mode selecting door control function selecting human sensitive function long distance monitoring temperature compensation value at the air return port Setting of Wired Controller s Address Enquiry and Setting of Wired Controller s Address Under off state of the unit press Function and Mode buttons at the same time for 5s to enter setting interface of wired controller s address In this case LCD displays address number Then press A or VW button to adjust address and then press Enter Cancel button to confirm The address setting is related to the setting of Debugging Function 4 9 10 When the selection in 4 9 10 is 00 address of centralized controller is to be set and the address setting range is 01 16 when the selection in 4 9 10 is 01 address of long distance monitor is to be set and the address setting range is 01 255 Enquiry and setting of wired controller s address is shown as below Enter Cancel A Function v Timer On Off Eo y Timer On Off Function h Timer On Off Off state of the unit Press Function and Mode buttons at Press A or V button to adjust the same time
27. rgized initially By pressing the TEMP button when the temperature symbol ry is displayed the indoor displayer will show the indoor setting temperature when n1 is displayed it will show the indoor ambient temperature when ar is invalidation If current displays indoor ambient temperature if received the other remote control signal it will display presetting temperature 5s later will back to display the ambient temperature This function is applicable to partial of models By pressing this button it is available to go to the TIMER OFF setting state with the same setting method as that of the TIMER ON in which case the OFF symbol blinks In the Cool or Heat mode pressing this button can activate or deactivate the TURBO function When the TURBO function is activated its symbol will be displayed when the running mode or the fan speed is changed this function will be canceled automatically This function is applicable to partial of models By pressing this button Sleep On and Sleep Off can be selected After powered on Sleep Off is defaulted Once the unit is turned off the Sleep function is canceled When Sleep is set to On the symbol of SLEEP Cc will display Under the Fan and Auto modes this function is not available Press this button to select LIGHT on or off in the displayer When the LIGHT is set to on the icon Pen will be displayed and the indicating light in the displayer will be on When the LIGHT is set t
28. strong electromagnetic interference place signal wire and communication wire of wired controller must use shielding twisted wire Installation of Wired Controller Firstly the selection and connection way of wired controller s signal wire are as below 1 Choose suitable signal wire 2 core signal wire wire diameter gt 0 75mm wire length lt 30m and the recommended length is 8m 2 Make sure the power of indoor unit is cut off fix the signal wire of wired controller on the wiring board for wired controller of indoor unit with screws make sure the signal wire is solid Then the detailed installation procedures of wired controller are as shown in Figure 2 5 2 Figure 2 5 2 Installation of wired controller Brief instructions of installation procedure 1 Pull out the 2 core signal wire in the installation hole of the wall and then let this wire go through the hole at the back of wired controller s base plate 2 Fix the base plate and installation hole of the wall together with screw M4x25 3 Fix the above mentioned 2 core signal wire on the copper insert X1 and X2 with the equipped screws of wired controller 4 Fasten the wired controller s panel with its base plate together Removal of Wired Controller Figure 2 5 3 Removal of wired controller TROUBLESHOOTING Display of Error Code Table 2 6 1 Error Code List Compressor high pressure protection Freeze protection Compressor low pressure protection refrig
29. t temperature is 16 C continuously press W button for twice and then the set temperature will be 12 C In this case the unit will enter low temperature drying function When low temperature drying function is turned on press A button or Mode button to exit low temperature drying function Lock Function When unit is turned on normally or turned off pressing A and VW buttons at the same time for 5s will turn on Lock function LCD will display E Pressing A and buttons at the same time for 5s to turn off this function When Lock function is turned on any other buttons wont respond when pressing The function can be memorized after power failure and then power recovery Memory Function Press Mode and A buttons at the same time for 5s under off state of the unit to turn on or cancel memory function If memory function is set REJ is displayed If not indoor unit is defaulted to be off after power recovery If memory function is set indoor unit will resume original setting state after power failure and then power recovery Note If cut off power with 5s after memorized content is changed the memorized content may be abnormal Do not cut off power within 5s after memorized content is changed Door Control Function Human Sensitive Function Door control function or human sensitive function can be selected More details please refer to Debugging Function These two functions can t be turned on at the same time When door control function
30. to enter setting of address address Enter Casvtel A 6 Function y Timer On Off Press Enter Cancel button to confirm and exit setting interface Figure Enquiry and setting of wired controller s address Setting of Master Slave Wired Controller s Address Under off status of the unit press Enter Cancel and Mode buttons at the same time for 5s to go to the enquiry and setting interface of master slave wired controller In this case LCD displays wired controller s address 01 for master wired controller and 02 for slave wired controller Press A or W button to adjust address of master slave wired controller and then press Enter Cancel button to confirm If slave wired controller is set the icon will be displayed Note If there is only one wired controller it only can be set as the master If there are two wired controllers one should be the master and the other should be the slave Setting of master slave wired controller s address is shown as Figure below Enter Cancel Enter Ce cel A Enter Cancel Function y Timer On Off Function y Timer On Off Function Timer On Off Off state of the unit Press Enter Cancel and Mode Press A or V button to adjust buttons at the same time to enter address setting of master slave wired controller s address Enter Cangel A Function y Timer On Off Press Enter Cancel button to confirm and exit setting interfa
31. ton off the unit the Sleep function will be canceled but the presetting time is still remained By pressing this button Auto Cool Dry Fan Heat mode can be selected circularly Auto mode is default after power on Under the Auto mode the setting temperature will not be displayed Under the Heat mode the initial MODE value is 28 C 82 F Under other modes the initial value is 25 C 77 F button 6 o POREN N AUTO COOL t DRY ee FAN XX HEAT only for cooling and heating unit a 66 Preset temperature can be decreased by pressing this button Pressing and holding this button for more than 2 Buton seconds can make the temperature changed quickly until release this button and then transmit this order The temperature adjustment is unavailable under the Auto mode but the order can be sent by pressing this button Centigrade setting range 16 30 Fahrenheit scale setting range 61 86 Preset temperature can be increased by pressing this button Pressing and holding this button for more than 2 ebuton seconds can make the temperature changed quickly until release the button and then transmit this order The temperature adjustment is unavailable under the Auto mode but the order can be sent by pressing this button Centigrade setting range 16 30 Fahrenheit scale setting range 61 86 By pressing this button Auto Low Middle High speed can be circularly selected After power on Auto fan speed is defau

Download Pdf Manuals

image

Related Search

Related Contents

Apple 210 Laptop User Manual  Mode d`emploi Connecteur vissé pour bridges vs 3 sv btg  as a PDF - Real  Worldwide Lighting W83091C25 Installation Guide  agrichim fenmedifam  Detalle del Producto  HP Smart Array Controller Driver for Solaris 10 User Guide  es élections des 9 et 16 mars ont porté aux  Produkthandbuch SJ200  1 - Goodluckbuy  