Home

GSM-LINE ADAPTER PRO 5 GSM 900/1800 MHz USER MANUAL

image

Contents

1. e The adapter can be set to forward the SMS messages arriving to the SIM Card to one or two phone numbers This function makes the use of non subscription cards more secure since the owner user can get the message about the actual balance to his own phone set e In connection with certain special devices e g emergency telephone a telephone number can be set which the module will automatically call when the receiver is picked up e Moreover as a result of short circuit contact IN1 IN2 IN3 inputs it is possible to send an SMS message with pre set text e By means of OUT1 and OUT2 open collector outputs it is possible to turn on and off different devices remotely through a telephone call Operation of the Unit In case of incident the alarm system initiates a call to the monitoring station The adapter continuously watches the existence and the functioning of a wired phone line If there is a functioning wired phone line the unit directs the call to it otherwise if no wired line is connected or the connected line does not work the unit initiates the call through the GSM network Usually an alarm system can be programmed to give a PGM output signal if it could not access the monitoring station on several attempts e g due to some fault in the telephone exchange or sub exchange Connecting the mentioned output of the alarm system to the IN4 DIRECT GSM terminal of the adapter it is possible to switch over to direct GSM transmission
2. is necessary to access the external PSTN main line this number must be given the adapter so that it shall omit this number from the called number in case of initiating a GSM call To do this enter a new item into the telephone directory of the SIM card under the name PREFIX and give the number that is necessary to access the external main line as a phone number e g 9 This newly entered parameter can be used when it has been downloaded into the adapter s own memory as detailed in the section Setting the Parameters of the Adapter Setting can also be performed with Pro5 programmer by means of the computer through serial port x Phone numbers SMS settings Call Filter Output Control Primary User HUSER1 Secondary User HUSER2 1 SMS forward nr SMSFW1 2 SMS forward nr HSMSFW2 Automatic dial nr AUTO Dial prefix number used for outside line HPREFIX Prefix to add before phone numbers called in GSM mode HADDFIX Cancel changes As it can be seen on the picture there is an ADDFIX parameter This is another prefix number which the module inserts in front of the dialled number in all those cases when the telephone call takes place through GSM network GSM mode For example if the alarm system calls the wired telephone number without the area code with this parameter the area code can be added in case of calls through GSM network In fact this function got vital importance because o
3. 31 before the telephone number telephone number display is enabled on the called person s telephone and by entering 31 this function is disabled 10 PC RS232 A Antenna B Metal house C Antenna adapter cable D GSM Line Adapter Pro 5 E Antenna connection F SIM card case G GSM module H Power supply terminals 9 24V DC I RS232 connector for the communication with PC J Connectors GSM LINE 2 wire Generated telephone line PSTN line connector towards the alarm system PSTN 2 wire Connector for incoming wired telephone line IN1 contact input for sending SMS IN2 contact input for sending SMS IN3 contact input for sending SMS IN4 DIRECT GSM function COM common point ground for IN1 IN4 inputs OUT1 output that can be remote controlled through a telephone call open collector OUT2 output that can be remote controlled through a telephone call open collector OUTS output for signalling the failure of GSM line that lasts longer than 3 minutes open collector OUT4 output for signalling the failure of wired line that lasts longer than 3 minutes open collector K Incoming wired telephone line PSTN L Telephone line input of alarm system M Pushbutton 11 Technical Data Supply voltage 9 24V DC Maximum power consumption 500 MA Operational temperature between 10 C and 60 C Transmission frequency GSM 900 MHz PCN 1800 MHz Dimensions 127
4. The pushbutton on the adapter serves two functions e Pressing for a short time you can test the field strength see the section Testing the GSM Field Strength and Listening to the line e Pressing for a longer time at least for 5 seconds you can start the process of loading the data stored on the SIM card into the module see the section Setting the Parameters of the Adapter Controlling outputs OUT1 and OUT2 open collector outputs can be turned on and off remotely through a telephone call For this set the parameters below in PRO5_programmer program Pro5 Settings A x Phone numbers SMS settings Call Fiter Output Control Enable Output Control from the following phone numbers 1 Enabled phone number rare 2 Enabled phone number MEME AAA 3 Enabled phone number Rial 4 Enabled phone number naaa sal 1 Controllable Output Timing 0 255 sec O bistable 255 2 Controllable Output Timing 0 255 sec O bistable 255 3 Output GSM error signal 4 Output Wired phone line error signal Commands during the call 14 OUTI ON 24 OUT2ON 44 OUT1 OFF 5 OUT2 OFF Cancel changes Remote control will be reachable from the numbers set here If there is an incoming call from any of the here given numbers the module does not forward the call to the security panel or the telephone set but automatically receives the call A beep signals ready to use condition in the telephone and t
5. even if a functioning wired phone line is connected to the adapter Preparation of the SIM Card The SIM card necessary for the operation of the unit can be bought from any GSM service provider The adapter is independent of the actual GSM network For preparation and programming purposes insert the SIM card into a mobile phone and perform the following settings Before starting to setup the adapter go through the following steps using the mobile phone e Make sure that the number of the SMS message centre is correctly set on the SIM card e Disable the PIN code request on the SIM card so that it shall not prompt for a PIN code on turning the unit on e Delete the unnecessary SMS messages from the card Setting the Parameters of the Adapter For the basic operation of the unit it is not necessary to set any parameter on the SIM card However in order to reach the additional functions of the adapter as detailed in the following sections it is required to set certain parameters e g the owner s phone number the number to be dialed to access the external PSTN line the texts of SMS messages etc These parameters can be entered in two ways e By means of a computer from www tell hu with the freely downloadable Prod programmer through serial port e By means of the SIM card inserted in the module in the form of telephone directory entries phone numbers and stored SMS messages Only core settings can be reached by mean
6. the customer identification code into the directory of the SIM card under the name HUSERID just like when entering a phone number the module will watch only the reports having this customer identifier e Enter the incident codes that should be responded by the unit and the texts belonging to them as SMS messages into the SIM card In case of CONTACT ID format the SMS message must start with a 4 digit incident code then comes a character and then you can enter the required message e g 1130 Burglary The first digit 1 means new event or opening or 3130 Restore after burglary The first digit 3 means restore event or closing You can use the joker character in the incident code then the adapter accepts any digit in the place of the joker character e g 313 Alarm In this case the module will send a message when it observes any incident that has a code starting with the 313 sequence 3130 3139 In case of Ademco Express format you have to create similar SMS messages with the only difference that the incident codes have only two digits e g 31 Burglary Here you can also use the character e g 3 Alarm This message will be sent in case of any incident with a code between 30 and 39 Note By entering character in the text of SMS in the sent SMS the information of event code partition zone will appear instead of Note In general a maximum number of 10 messages can be stored on the SIM card
7. GSM LINE ADAPTER PRO 5 GSM 900 1800 MHz USER MANUAL Functions of the Unit The purpose of the GSM LINE ADAPTER PRO 3 is to interface to GSM network an alarm system that can inform the security monitoring station through wired telephone line There are two main application areas of the unit e This adapter makes it possible to install alarm systems in places where there is no wired PSTN line but it can be necessary to alarm the security monitoring station e By means of the GSM transmission the adapter improves the reliability of alarm reporting in cases when the wired alarm transmission does not work or fails e g when the phone lines are tampered or the telephone service is suspended due to technical reasons The adapter has some additional functions e The unit continuously watches if a CONTACT ID or ADEMCO Express report is directed towards the security monitoring station through the wired or GSM network and if either of the preset report codes is noticed it sends an appropriate SMS message with definable text to one or two telephone numbers Using this function the owner can get instant SMS messages not only of alarms but also of every event of closing opening e The module can convert CONTACT ID signals into SMS messages without being connected to the monitoring station To do this enter 123456789 instead of the telephone number of the monitoring station In this case GSM Line Pro 5 module will simulate the monitoring station
8. events the eventual incoming calls from disturbing the outgoing calls initiated by the alarm system Furthermore incoming calls can be restricted according to telephone numbers This function can only be set by means of PRO5 programmer and not by SIM card downloading After SIM card downloading the module enables all incoming calls Pro5 Settings x Phone numbers SMS settings Call Filter Output Control E Filtering incoming calls C Enable all incoming call Enable calls from the following phone numbers only 1 Enabled phone number narrada 2 Enabled phone number aerea 3 Enabled phone number REPARA 4 Enabled phone number EESAAAAAAAAAAAAA Incoming call time limitation 0 25 min O no limit 25 Cancel changes The duration of incoming calls can be restricted as well Important note In case of telephone number restriction do not write the inland area changing prefix before the telephone number only the area code and telephone number The telephone uses international format 3630 while displaying telephone numbers The module compares the received telephone number with the restricted telephone number by starting to compare them from the last digits The module handles the two numbers as identical even if 36 is left out Setting a prefix number necessary to access external PSTN line If the module is connected to a wired network where the dialing of a certain number e g 9
9. f the characteristics of some foreign wired telephone line networks Forwarding Incoming SMS Messages It is possible to send the messages received by the SIM card to one or two other phone sets This makes safe the use of cheap non subscription cards for security purposes To do this enter the one or two phone numbers that you would like to get the incoming SMS messages under the name s SMSFW1 and SMSFW2 into the directory of the SIM card These parameters have to be loaded over into the module s own memory according to the section Setting the Parameters of the Adapter Setting can be done with Pro5 programmer by means of a computer through serial port according to the picture above Note When the module successfully forwarded the incoming SMS message the message will be deleted from the SIM card to make space for further incoming messages Sending SMS Messages In Case of Alarms or Other Incidents The adapter continuously watches the calls initiated through the GSM network and notices the reports of CONTACT ID or ADEMCO Express formats If it observes any of the given incident codes maximum 10 it will send an SMS message to one or two telephone numbers with a text that can be set by the user This function needs the setting of the following parameters e Enter the phone numbers that you would like to send the SMS message to into the directory of the SIM card under the names USER1 and USER2 e Also enter
10. he two outputs can be controlled through the phone by pushing the below mentioned buttons 1 turn on OUT1 2 turn on OUT2 4 turn off OUT1 5 turn off OUT2 On the picture above it can also be set that the output should automatically turn off in certain given seconds after it is turned on Important note Do not use area changing prefix when entering the telephone number use only area code and telephone number the same way as described in Receiving calls through the GSM network section LED Lights of the Unit There are six LED lights on the module indicating the following operational conditions POWER Indicates that the power supply is on GSM NETWORK e Its continuous lighting indicates that the module is connected to the GSM network e lf the LED does not light at all the attempt to sign in the GSM network has failed or is in progress PSTN MODE indicates the existence of an operating wired telephone line GSM MODE Indicates that a call is going through the GSM network LED at output OUT3 Indicates that either the GSM module has not been able to connect to the network after trying it for 3 minutes or the field strength has decreased under the required minimal level for more than 3 minutes When the OUT3 LED is lighting the OUT3 output also gets activated and it can be fed back to the alarm system or used for initiating local alarming LED at output OUT4 Indicates if the wired line has not been in operati
11. ng mode for more than three minutes At the same time the OUT4 LED signals the OUT output also gets activated and this can be fed back to the alarm system or used for initiating local alarming PSTN MODE and GSM MODE The slow alternate blinking of these two LEDs indicates that there are no parameters loaded from the SIM card in the module or the loading process was unsuccessful Their quick alternate blinking indicates that the loading process of the parameters from the SIM card is in progress Instructions on Installation Before installing check the future environment of the adapter e Test the field strength with your mobile phone It may happen that the field strength is not sufficient in the selected place In this case you can change the planned installation place before you mount the adapter If there are field strength problems on the site of installation order a longer antenna adapter that enables you to put the antenna higher e Do not mount the unit in places where it is influenced by strong radiofrequency disturbances e g near electric motors etc e Do not mount the unit in wet or humid places Mounting Plastic fixing clips are supplied with the unit If it is possible put the GSM adapter into the same metal house as the alarm system If there is not enough room in the house of the alarm system put the adapter into another metal case Fix the antenna on top of the case Only after the antennae is fixed should you star
12. s of SIM card downloading for setting extended functions the use of Pro5_programmer is necessary In the latter case insert the SIM card into a normal mobile phone and enter the necessary parameters as phone numbers into the directory Enter the necessary SMS messages too but instead of sending them save them on the SIM card by selecting SAVE in the menu This will result in putting the message among the messages that can be sent later It is important that the telephone numbers and SMS messages should be stored on the SIM card and not in the telephone s own memory When you have entered the necessary parameters into the SIM card make sure that the adapter is not under voltage and put the card into the SIM case of the unit Then connect the power supply to the panel and push the button next to the SIM case for approx 5 seconds until PSTN MODE and GSM MODE LEDs start quick alternate blinking Then the adapter loads over the corresponding parameters from the SIM card into its own memory This process lasts about 2 minutes and then the quick blinking terminates If the loading was not successful e g due to a break in the power supply the slow alternate blinking of the two LEDS indicates that the loaded data are faulty Then you must start the loading procedure once again The module only reads and does not modify data on the SIM card Function of the IN4 DIRECT GSM Input Short circuiting the IN4 input the module
13. switches over to GSM transmission i e irrespective of the existence of an analogue phone line the adapter initiates the call through the GSM network This ensures the call transmission in case there is some fault in the telephone exchange or sub exchange i e if the wired phone line seemingly works but the alarm system cannot reach the monitoring station through the wired PSTN network Most alarm systems can be programmed to give an output PGM signal after a certain number of unsuccessful attempts If this signal arrives to the IN4 input of the adapter i e the wired line cannot be used the unit will initiate the next call through the GSM network If there is no wired telephone line connected to the adapter additional care must be taken to connect the IN4 input as follows If it is necessary to manage incoming GSM calls connect the IN4 input to the alarm system so that it will short circuit the input at the time of starting a call This is important to prevent an eventual incoming call from disturbing alarm reporting Receiving calls through the GSM network GSM LINE ADAPTER PRO 5 is able to manage the calls coming through the GSM network i e it can receive the incoming GSM calls by means of a simple analogue telephone set in places where there is no wired phone line extension This function works only if there is no wired telephone line connected to the module and the IN4 DIRECT GSM input is not short circuited This input of the module pr
14. t may reach 500 mA during communication Setting by means of the computer All necessary parameters for the operation of the module beside downloading from a SIM card can be done by means of a PC Download Pro5_ programmer from www tell hu on the Internet For programming it is necessary to have a 9 pole serial connecting cable serial mouse expanding cable Connect the modul and the PC with the serial cable Run the program and choose the serial port where the module has been connected With this program not only settings but the operation of the module can be traced as well Further notes e The adapter accepts both Tone DTMF and Pulse dials e The adapter does not know the length of the number to be dialled in advance therefore do not wait too long before entering the next figure at because if you do so the module might suppose that dial has already finished The adapter expects at least 7 figures and does not start dialling until they are entered It starts calling a number of 7 and 10 digits after a 5 second pause In case of 11 or more figures the adapter starts dialling after a 2 second pause If alarm systems are included the above mentioned does not mean a problem because of the quick automatic dial you have to consider this problem only in case of manual dial e You can dial telephone numbers shorter than 7 digits by entering after the number Enabling and disabling telephone number display By entering
15. t mounting the alarm system and the adapter Screw the bigger connector of the antenna adapter cable into the antenna connector then carefully flip the other end of the cable into the mini connection of the telephone module IMPORTANT NOTE Make sure that you do not force and drag the antenna cable while fixing it because we do not take guarantee if a mechanical damage occurs Connections e In case a wired telephone line exists connect the ends of the phone line to the terminal PSTN The polarity is indifferent If the PSTN MODE LED lights the line has been connected correctly The signal of PSTN MODE LED is delayed e Connect the phone line input of the alarm system to the GSM LINE output of the GSM adapter with the shortest cable possible Here the polarity is also indifferent Use possibly shielded cable and connect one end of the shielding to the ground potential while leaving the other end free e Installation of further connections IN1 IN2 IN3 IN4 OUT1 OUT2 OUT3 OUT4 can be done if requested see at functions Setting Up e Click the SIM card in its place if it is necessary in programmed state PIN code request should be disabled e Make sure that the connections correspond to the above instructions e Put the unit under supply voltage 9 24V Make sure that the energy supply capacity is enough when the alarm system and the adapter are working together The rest current of the adapter is 200 mA but the curren
16. therefore if you wish to send further SMS messages as a result of IN1 IN2 IN3 inputs besides the mentioned 10 messages the use of Pro5_programmer is necessary for the setting Note The module does not perceive signals sent through wired telephone lines Note In Pro5_programmer when an ADEMCO Express code is entered two zeros have to be inserted before the code e g in case of 31 alarm 0031 has to be entered in the program xl Phone numbers SMS settings can Filter Output Control SMS text LTT The character in the SMS text will be replaced to eventcode partition zone Cancel changes Sending SMS as a result of IN1 IN2 IN3 inputs It is possible to send SMS to telephone numbers USER1 s USER2 due to short circuit impulse on IN1 IN2 IN3 inputs For this enter an SMS message to the SIM card as described previously starting with 1 2 or 3 then continuously the text of the message to be sent as a result of the given input The prepared SIM card must be downloaded to the module as described earlier In the picture above you can also see how to set this parameter Sending SMS messages on event without being connected to a monitoring station If you do not wish the alarm system s signals to be directed to the monitoring station it is still possible to send SMS messages in case of some events To do this enter 123456789 instead of the telephone number of the monitoring sta
17. tion into the device In case of alarm the device will dial this number The adapter module does not initiate a real phone call but simulates the operation of the monitoring station gives out handshake signals and acknowledges CONTACT ID and ADEMCO Express signals It is possible to send SMS messages about the received signals For this the SMS messages to be sent have to be preset as it is described in the previous section Automatic dial In certain specific tasks e g emergency calls the following function can be used Enter a telephone number and call it AUTO into the telephone directory of the SIM card then load it into the module As a result the module shall immediately initiate a call to the preset number through GSM network when the receiver is picked up See picture at setting prefix numbers Preparation of the Alarm System Before installing the adapter check the following settings on the alarms system e The report format must be set to CONTACT ID or ADEMCO Express e The call numbers of the monitoring station must be given together with district numbers so that they can be called from the SIM card through the GSM network e Dialing should be set to TONE mode Testing GSM Field Strength After the pushbutton on the adapter has been pressed for a short time the number of blinks of the GSM MODE LED on the adapter indicates the actual field strength on a scale between 1 and 5 Pushbutton Functions
18. x86x27 mm Net weight 709 Gross weight packed 400 y e Outputs OUT1 OUT2 OUT4 OUT4 o open collector outputs current max 100mA allowed smallest load min 150 Ohm it is necessary to use protecting diodes in case of using relays e g 1N4004 It is forbidden to connect it on supply voltage without loading O A 0 O Min 150 Ohm e g relay Error output Data of generated telephone line Line voltage 48 V Line current 25 mA Line impedance 600 Ohm Ringing voltage 72 V 25 Hz Dial tone 400 Hz Supply Content GSM LINE ADAPTER PRO 5 Antenna adapter cable MMCX FME GSM 900 MHz PCN 1800 MHz antenna 4pieces of fixing supports User s Manual Letter of Guarantee Summary table of parameters SMSFW1 Phone numbers necessary for forwarding the incoming SMS messages SMSFW2 PREFIX Prefix number necessary to access the external PSTN line USER1 Phone numbers that get SMS messages from the module in case of observing USER2 given incident codes ADDFIX Prefix number that should be added to telephone numbers called in GSM mode AUTO Phone number for autodial function 12

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi des auto-injecteurs EpiPenMD et EpiPenMD Jr.  “USER`S MANUAL” - Allparts Equipment & Accessories  Samsung SGH-E770 Instrukcja obsługi  SilberSonne DL25WW8D LED lamp  CMBB Manual F PDF Content REV.p65  GESBC-9302EX User`s Manual  Targus Strata Slipcase  SP-900 User`s Manual  OKI V40APHS Manual - Recambios, accesorios y repuestos  