Home
curing light led.g user`s manual
Contents
1. 2 Applied part optical fiber 4 3 Light source Blue light Wave length 420nm 480nm Light intensity 1000mW cm 1200mW cm 4 4 Working condition Environment temperature 5 C to 40 C Relative humidity lt 80 Atmosphere pressure 70kPa to 106kPa 4 5 Dimensions 26mm 25mm 260mm 4 6 Net weight 135g 4 7 Consumption power lt 8W 4 8 Protection type against electrical shock class II 4 9 Protection against electrical shock type B 4 10 Protection against harmful ingress of water or particular matter ordinary equipment IPX0 4 11 Safety in the presence of flammable anesthetic mixture with air oxygen or nitrous oxide not suitable under this condition 4 12 Intermittent operation instrument after work 200 seconds stop 20 seconds and then work 20 seconds stop 20 seconds work in the rule as above circularly 5 Install and uninstall way 5 1 Connect the LED power supply line with the power 24V of dental unit Tight the nylon thread to the fixation of the dental unit then it will be available for operation Notice When installing the LED be sure the power is cut off The two power wire should be a little longer than the nylon thread to keep the power wire safe 5 2 Take off the red cap from the optical fiber and insert the metal part into the front of the built in LED G Make sure to screw the fiber to the end by rotation 5 3 Install the light hood as showed in picture 1 5 4 Uninstall the LED just reverse the p
2. more information Guilin Woodpecker Medical Instrument Co Ltd eal Information Industrial Park National High Tech Zone Guilin Guangxi 541004 China Tel Europe Sales Dept 86 773 5873196 86 773 2125222 North America South America amp Oceania Sales Dept 86 773 5873198 86 773 2125123 Asia amp Africa Sales Dept 86 773 5855350 86 773 2125896 Fax 86 773 5822450 E mail woodpecker mailgl cn sales glwoodpecker cn Website http Awww glwoodpecker com Wellkang Ltd www CE Marking eu 29 Harley St LONDON W1G 9QR UK ZMN WI 04 557 2 3 Edition
3. of the test level 10 Guidance amp Declaration Electromagnetic immunity The model LED G is intended for use in the electromagnetic environment specified below The customer the user of the model LED G should assure that it is used in such an environment IEC 60601 test Compliance Immunity test level level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the model LED G including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms _ 12 IEC 61000 4 6 150 kHz to 80 MHz Radiated RF je 1 2 IEC 61000 4 3 B0 MHz to 2 5 GHz 297 MP d 2 3xP 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter In watts W according to the transmitter manufacturer and d Is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur In the vicinity of equipment marked with the following symbol P NOTE I At 80 MHz end 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected
4. of transmitter power of transmitter 150kHz to 80MHz MI 800MHz to 2 5GHz w 1 2 1 2 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W accordable to the transmitter manufacturer NOTE At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people The device has been tested and homologated in accordance with EN 60601 1 2 for EMC This does not guarantee in any way that this device will not be effected by electromagnetic interference Avoid using the device in high electromagnetic environment 19 Statement All rights of modifying the product are reserved to the manufacturer without further notice The pictures are only for reference The final interpretation rights belong to GUILIN WOODPECKER MEDICAL INSTRUMENT CO LTD The industrial design inner structure etc have claimed for several patents by WOODPECKER any copy or fake product must take legal responsibilities 12 Scan and Login website for
5. protection There is not any harmful element in our product It can be disposed according to the local laws 15 Manufacturer s right We reserve the rights to change the design of the equipment the technique fittings the instruction manual and the content of the original packing list at any time without notice If there are some differences between blueprint and real equipment take the real equipment as the norm 16 For technical data please contact 29 Harley St LONDON WI G SR Uk 17 Symbol instruction gn Trademark iN Type B applied part IPXO Ordinary equipment i Consult the accompanying documents Date of manufacture pal Manufacturer I B 2 DS o a EI o a a gt 5 G Q 4 E r s 4 E r L ON 7A 3 Used indoor only Screw inside outside Class I equipment Appliance compliance WEEE directive Recovery Atmospheric pressure for storage Temperature limitation Humidity limitation Keep dry Handle with care CE marked product FDA marked product Authorised Representative in the EUROPEAN COMMUNITY atte Got the quality management system certification Suec son o tas Assisii and CE certification issued by T V Rheinland 18 Declaration of conformity 18 1 Product conforms to the following standards EN 60601 1 2006 EN 1041 2008 EN 60601 1 2 2007 EN ISO 14971 2009 EN 61000 3 2 2006 EN ISO
6. 7405 2008 EN 61000 3 3 2008 EN ISO 17664 2004 EN 60601 1 4 1996 EN ISO 17665 1 2006 EN 60825 1 2007 EN ISO 10993 1 2009 EN 980 2008 EN ISO 10993 5 2009 ISO 9687 1993 EN ISO 10993 10 2010 18 2 EMC Declaration of conformity Guidance and manufacturer s declaration electromagnetic emissions The model LED G is intended for use in the electromagnetic environment specified below The customer or the user of the model LED G should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions The model LED G uses RF energy only for its internal function CISPR 11 Group 1 Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RE emissions ClassB model LED G is suitable for use in all establishments other CISPR11 z than domestic and those directly connected to the public low Harmonic emissions 1 tes IEC 61000 3 2 Not applicable voltage power supply network that supplies buildings used for Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable domestic purposes Guidance amp Declaration electromagnetic immunity The model LED G is intended for use in the electromagnetic environment specified below The customer or the user of the model LED G should assure that It is used in such an environment 3 IEC 60601 Compliance Elec
7. WOODPECKER tuv d Co GUILIN WOODPECKER MEDICAL INSTRUMENT CO LTD www glwoodpecker com KA EN ISO 13485 Content Introduction Principle and usage Structure and components Technical specifications Install and uninstall way Operation Precaution Contraindication 9 Maintenance 10 After service 11 Troubleshooting 12 Packing List 13 Storage and transportation 14 Environmental protection 15 Manufacturer s right 16 For technical data please contact 17 Symbol instruction 18 Declaration of conformity 19 Statement NVOYNADADAADUNUWNA KAWNEER 1 Introduction Guilin Woodpecker Medical Instrument Co Ltd is a high tech enterprise in researching developing and producing dental equipment and has a perfect quality assurance system main products including ultrasonic scaler curing light micro motor apex locator and ultrasurgery etc 2 Principle and usage 2 1 LED G adopts the principle of ray radiation to solidify the light sensitive resin by shooting at it in a short time 2 2 This product is used to restore teeth and solidify material for whitening teeth 3 Structure and components LED G dental is composed mainly of high power LED optical fiber and main unit Picture 1 4 Technical specifications 4 1 Power supply 24V 50Hz 60Hz 4
8. blems please refer to the warranty card for the warranty period for units and parts 11 Troubleshooting Non indication 1 The LED is not connected 1 Check the connection of Non act well with the power the LED and the power 2 The power is off 2 Make sure the power is on Light intensity 1 Optical fiber isn t inserted 1 Install the optical fiber insufficient well to the bottom well 2 The optical fiber has 2 Change the optical fiber cracked 3 Remove the resin 3 There is resin remain on the surface of the optical fiber If all the above solutions have been completed the machine still can not work normally Please contact our special repair shop or us 12 Packing List The components of the equipment are listed in the packing list 13 Storage and transportation 13 1 This equipment should be handled carefully kept away from shaking point installed or stored at shadowy dry cool and ventilated places 13 2 Don t store it together with articles that are combustible poisonous caustic and explosive 13 3 This equipment should be stored in the environment where the relative humidity is lt 80 the atmosphere pressure is 70kPa to 106kPa and the temperature is 10 C to 55 C 13 4 Excess impact or shake should be avoided during transportation 13 5 Don t mix it with dangerous articles during transportation 13 6 Keep it away from sun or snow or rain during transportation 14 Environmental
9. by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the model LED G is used exceeds the applicable RF compliance level above the models LED G should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the model LED G Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3V m 11 Recommended separation distances between portable and mobile RF communications equipment and the model LED G The model LED G is intended for use in electromagnetic environment in which radiated RF disturbances is controlled The customer or the user of the model LED G can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the model LED G as recommended below according to the maximum output power of the communications equipment Rated maximum output Separation distance second to frequency
10. rocedure above Light hood Screw inside Full power outside Ramping Pulse Power supply pipe Optical fiber On off button Mode switch Picture 1 6 Operation You can choose one of three operation modes by pressing the mode switch button on the curing light 6 1 Full power the blue light radiates in full power 6 2 Ramping The blue light power increases stronger continually after five seconds reaches to the highest power 6 3 Pulse The blue light works on the pulse condition During the operation aim blue solidification The working time of all modes is ten seconds 7 Precaution 7 1 During operation the light should be aimed straightly on the resin to ensure solidification effectively 7 2 Avoid aiming light at eyes directly WARNING If the curing light works for 40s continously the temperature of the top of optical fiber may reach 56 C WARNING Do not modify this equipment without authorization of the manufacturer 8 Contraindication The heart disease patients pregnant women and children should be cautious to use this equipment 9 Maintenance 9 1 Only the optical fiber can be autoclaved under high temperature and pressure 9 2 After operation each time please shut off the power source and clean the optical fiber 10 After service From the date this equipment has been sold base on the warranty card we will repair this equipment free of charge if it has quality pro
11. tromagnetic environment Immunity test 1 test level level guidance Electrostatic Floors should be wood concrete or discharge ESD 6 kV contact 6 kV contact ceramic tile If floors are covered 8 kV air 8 kV air with synthetic material the relative IEC 100042 humidity should be at least 30 gemere Lee ey transient burst pes ya Scent IEC 61000 4 4 1 kV for Input output pply d lines Surge 1 kV line to line ENT iius S esl quality nip be M applicable of a typical commercial or hospital IEC 61000 4 5 2 KV line to earth PP environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 lt 5 Ur gt 95 dip in Ur for 0 5 cycle 40 Ur 60 dip in U7 for 5 cycles 70 Ur 30 dip in U7 for 25 cycles Not applicable Mains power quality should be that of a typical commercial or hospital environment If the user of the model LED G require continued operation during power mains interruptions it is recommended that the model LED G be powered from an uninterruptible power supply or a battery lt 5 Ur gt 95 dip in U7 for 5 sec Power frequeno Power frequency magnetic fields 50 60 Hz should be at levels characteristic of magnetic field 3 Alm 3 A m a typical location in a typical commercial or hospital IEC 61000 4 8 environment NOTE Uz is the a c mains voltage prior to application
Download Pdf Manuals
Related Search
Related Contents
Configuración de las direcciones IP Manual de Usuario PDF Guía del usuario MEMDOS E/DX Betriebsanleitung - Lutz Life Fitness 95SW User's Manual Bedienungsanleitung Verti DELL Inspiron 7737 Copyright © All rights reserved.
Failed to retrieve file