Fisher ROC Plus Serial Driver Help

image

Contents

1. 16 Device address lt address gt is Read Only 0 00 22 sees sese ens 16 Device Set p 2i annee be ri cupcakes EB manne SPA Re AIR ae TER 2e gates 5 Device Specific Messages s e sRs sess e rr l annaa 18 Device Status Messages 18 E Error Descriptions e STAGE han Mans EVE Ea Da NE E Er CRD d Ted 15 Error importing CSV tag record record number Address Address is out of range for 20 the specified device or register Error opening COM 17 F Failed to obtain data block for PointType point type Logical Address address 18 Starting Parameter 7 starting parameter Ending Parameter ending parameter for device device Error ROC error code Failed to write data for PointType point type gt Logical Address address Param 19 www kepware com Fisher ROC Plus Serial Driver Help 25 eter lt parameter gt for device device Error error code gt H Help Contentss x a cune US ae D rue 4 L Location Details os cott e e d e o xe oe ede 12 Ses TL ter Ne re et eich che tes a he Ne ess aah ere heehee re 12 M Missing address i Rush ence oett Eoo dbubiigintoD dk ei ashe po teen tease 16 Modem Setup c sso dept debi ee nae RUNES Aa ERE Auk sh eats 8 More Tag Import Setmings es RR cece Rs esses essen 6 O Operator Identification n cece cece cece eee
2. caen rem Users have the option to create an OPC tag database based on either the device s configuration file or a ROCLINK 800 project file Descriptions of the parameters are as follows e Create tag database from device This parameter specifies that the driver will automatically create a set of OPC tags based on the device s configuration file www kepware com Fisher ROC Plus Serial Driver Help e Create tag database from import file This parameter specifies that the driver will automatically create a set of OPC tags based on a project file created in ROCLINK 800 Use the browse button to locate the file 800 to be imported e Display Descriptions When checked the tags will include descriptions from the ROCLINK 800 master database See Also More Tag Import Settings and Automatic Tag Database Generation More Tag Import Settings To view or change the Tag Import Settings after the device has been added right click on the device and then select Properties More Tag Import Settings New Device More Tag Import Settings xi If importing tags from a ROCLINK project set the location of the master ROC database file and the ROCLINK MD w file ROC Database System Files ROC mdb file ROC mdb ea ROCLINK MDw file ROCLINK MDW E Cancel Help To create a tag database from an import file use the browse button to locate the ROC mdb and ROCLINK MDW files These files a
3. Device Setup Supported Devices ROC809 ROC827 Supported Protocol ROC Plus Maximum Number of Channels and Devices The maximum number of supported channels is 100 The maximum number of devices per channel is 255 Ethernet Encapsulation This driver supports Ethernet Encapsulation which allows the driver to communicate with serial devices attached to an Ethernet network using a Serial to Ethernet server Ethernet Encapsulation mode may be enabled through the Communications tab in Channel Properties For more information refer to Ethernet Encapsulation in the OPC Server s help documentation Device Setup Dialogs General dialogs in the device setup process are described in the OPC server help Device setup dialogs that are specific to the Fisher Plus ROC Serial driver are described in the following topics Tag Import Settings More Tag Import Settings Address Specification Operator Identification Time Synchronization Tag Import Settings To view or change the Tag Import settings after the device has been added right click on the device and then select Properties Tag Import Settings New Device Tag Import Settings If importing tags from a ROCLINK project set the location of the tag import file to be used in tag database creation Select whether descriptions should be displayed if provided r Database Import Method Create tag database from import file Tag Import File Z Display Descriptions
4. 6 The username or password supplied was not accepted Error 63 Write request rejected on Read Only item reference channel name gt device name gt address Automatic Tag Database Generation Error Messages Error importing CSV tag record record number Address lt Address gt is out of range for the spec ified device or register Unable to generate a tag database for device device Reason Auto tag generation Unable to generate a tag database for device device Reason Failed to open recordset Unable to generate a tag database for device device Reason Input file is corrupt Unable to generate a tag database for device lt device gt Reason Input file not found Unable to generate a tag database for device lt device gt Reason Low memory resources See Also ROC Plus Error Codes Address Validation The following error warning messages may be generated Click on the link for a description of the message Address Validation Address lt address gt is out of range for the specified device or register Data Type lt type gt is not valid for device address lt address gt Device address lt address gt contains a syntax error Device address lt address gt is Read Only Missing address Address lt address gt is out of range for the specified device or register Error Type Warning Possible Cause www kepware com Fisher ROC Plus Serial Driver Help A tag address t
5. access data type length and description refer to the device s ROC Plus Protocol User Manual ROC Plus Point Types For a detailed listing of all point types parameters access data type length and description refer to the device s ROC Plus Protocol User Manual PRICES 85 HART 91 System Variables www kepware com Fisher ROC Plus Serial Driver Help 5 Communication Ports FST Parameters Logon Parameters Analog Inputs RT 2 9 9 9 2 6 7 0 10 10 10 Analog Outputs 10 10 10 0 116 Turbine Meter Run Values 118 Modbus Register to TLP Mapping 119 Modbus Event Alarm and History Table 117 Modbus Configuration Parameters 121 Modbus Master Table 1 Modbus Master Modem Configuration 1 DS800 Configuration 1 History Segment Configuration l 6 7 E PERS z ina See 141 Advanced Pulse Module 3 4 5 8 9 2 2 23 24 25 History Segment 0 Point Configuration 2 2 28 29 3 4 5 9 Binary Field BIN Example The table below shows an example alarm code from an Analog Input Point Type This is used to demonstrate how a binary parameter is returned A 1 in any bit indicates that it is active or enabled response Bit Crow Alarm 19 www kepware com Low Low Alarm li High Alarm High High Alarm Rate Alarm Not Used Point Fail Alarm Scanning Disabled Alarm www kepware com Fisher ROC Plus Serial Driver
6. is out of range for the specified device or register 15 Data Type lt type gt is not valid for device address lt address gt 16 Device address lt address gt contains a syntax error 16 Device address lt address gt is Read Only 16 Missing ET e oo seec bocce iis ose sees boos id bobs peed Sure D ashe ban CIE Re de ages 16 Serial Communications LL idee eee eeeeceecceeecee 16 Communications error on channel name gt lt error maskl else 16 COMA does not Exist 0 coL opi ace air el D ony dante Moe eng rm Ue e mnt 4 58 eke 17 COMn is in use by another application 17 Error opening COMM EEUU 17 Unable to set comm parameters on COM 17 Device Status Messages 18 Device lt device name gt is not responding 18 Device Specific Messages 18 Device lt device gt responded with error Tag lt tag address gt Details lt error code gt 18 Failed to obtain data block for PointType lt point type gt Logical Address lt address gt Starting Param eter start
7. on the configuration that the driver retrieved from the ROC controller and the ROC specification Nonetheless the ROC controller itself is the final authority on whether a datum is writable Note For more information refer to the controller s documentation Automatic Tag Database Generation Error Messages The following error warning messages may be generated Click on the link for a description of the message Automatic Tag Database Generation Error Messages Error importing CSV tag record lt record number gt Address lt Address gt is out of range for the spec ified device or register Unable to generate a tag database for device lt device gt Reason Auto tag generation Unable to generate a tag database for device lt device gt Reason Failed to open recordset Unable to generate a tag database for device lt device gt Reason Input file is corrupt Unable to generate a tag database for device lt device gt Reason Input file not found Unable to generate a tag database for device lt device gt Reason Low memory resources Error importing CSV tag record record number Address lt Address gt is out of range for the specified device or register Error Type www kepware com Fisher ROC Plus Serial Driver Help Warning Possible Cause An imported tag address specifies a location that is beyond the range of supported locations for the device Solution Verify that the address is correct if it is n
8. Help Fisher ROC Plus Serial Driver Help Error Descriptions The following error warning messages may be generated Click on the link for a description of the message Address Validation Address lt address gt is out of range for the specified device or register Data Type lt type gt is not valid for device address lt address gt Device address lt address gt contains a syntax error Device address lt address gt is Read Only Missing address Serial Communications Communications error on channel name gt lt error mask gt COMn does not exist COMn is in use by another application Error opening COMn Unable to set comm parameters on COMn Device Status Messages Device device name gt is not responding Device Specific Messages Device lt device gt responded with error Tag tag address Details error code gt Failed to obtain data block for PointType point type Logical Address address Starting Parameter starting parameter Ending Parameter ending parameter for device lt device gt Error ROC error code Failed to write data for PointType point type gt Logical Address lt address gt Parameter lt parameter gt for device lt device gt Error error code gt ROC initialization error Unable to read general configuration ROC initialization error Unable to retrieve I O map The username or password supplied was not accepted Error
9. I O map Error Type Serious Possible Cause Access to the I O Map has been restricted for the current user Solution Check the Operator Identification settings username password access level and verify that they are correct See Also Operator Identification www kepware com 20 Fisher ROC Plus Serial Driver Help The username or password supplied was not accepted Error 6 Error Type Serious Possible Cause An access level has been enabled on the device but not in the driver Solution Check the Operator Identification settings and make sure the Enable Access Level checkbox is checked See Also Operator Identification The username or password supplied was not accepted Error 63 Error Type Serious Possible Cause The access level that has been enabled on the device is lower than the operator s access level Solution Check the Operator Identification settings and make sure the operator s access level is less than or equal to the access level enabled in the device See Also Operator Identification Write request rejected on Read Only item reference channel name gt device name gt lt address gt Error Type Warning Possible Cause The driver was attempting to write to a Read Only datum in the ROC controller Solution 1 Do not attempt to write to Read Only points 2 In some situations the Automatic Tag Generation process will identify Read Only datum as Read Write based
10. Unable to read general configuration ROC initialization error Unable to retrieve I O map Device lt device gt responded with error Tag tag address Details error code gt The username or password supplied was not accepted Error 6 The username or password supplied was not accepted Error 63 Write request rejected on Read Only item reference channel name gt device name gt address Device lt device gt responded with error Tag tag address Details lt error code gt Error Type Serious Possible Cause 1 The connection between the device and the Host PC is intermittent 2 The communication parameters for the serial connection are incorrect 3 The value written is out of range 4 The write was performed while in an incorrect setup area Solution 1 Check the cabling between the PC and the device 2 Verify that the specified communication parameters match those of the device See Also Device Setup Failed to obtain data block for PointType lt point type gt Logical Address lt address gt Starting Parameter lt starting parameter gt Ending Parameter lt ending parameter gt for device lt device gt Error lt ROC error code gt Error Type Serious www kepware com Fisher ROC Plus Serial Driver Help 19 Possible Cause 1 Invalid tag address for point in block 2 Device not responding Solution 1 Consult the ROC error code refer
11. Fisher ROC Plus Serial Driver Help 2011 Kepware Technologies 2 Fisher ROC Plus Serial Driver Help Table of Contents Table of Contents ARA i H EVER o euge 2 Fisher ROC Plus Serial Driver Help 4 Overview orones SC EL S er te ne Pha deere 4 Device Setup bine ascent telat no EL PEU SEU Aaa EA RE VLA d LUE DU A etl E E EM RE d 5 Tag Import Settings aa cs I ST IS St en a es Neh 5 More Tag Import Settings L s see serrer rl 6 Address Specification DaDa anana 6 Operator Identification lt srra X 2 4 Z a ETT RTK R 39 2 0 R Haa L RRR ee EL 7 Time Synchronization 2 22 2 0 0 0 ccc ccc ccc cece cece cece ccc ececeeeeeeeteetetteettttettsttteteeenees 8 Modem Setups 605 poe PETER REPRERRE A A 8 Data Types Description i EE ed ein ia ten as usan exem lane io e cale 9 Automatic Tag Database Generation 11 Address Descriptions 12 Eogical7 Eocation Details 5 n 22 sees Lat ei UID T mia d A POI don Ant 12 ROC Plus Point Types oon eaa aeaa Jesus Ie e IREIDlrv dcin tec dos Ree otis 12 Binary Field BIN Example l2 13 Error Descriptions 2 222 220 IIR sss s elles l els l sells lll lll l illl 15 Address Validation ocv eo Uu eux aia ren Under 15 Address address
12. al Modbus range 63 Requested access level too high 65535 Device not responding www kepware com a Fisher ROC Plus Serial Driver Help Index A Access Level TTC 8 Address lt address gt is out of range for the specified device or register 15 Address Descriptions 12 Address Specificati On 2242 ooo gies M eset neo coss Ub dsl iia a eh trs Ee fU 6 Address Validation arise gee ne R a E R Dn 15 Automatic Tag Database Generation 11 Automatic Tag Database Generation Error Messages 20 B BIN nerp H 13 Binary Field Example IIR Rs seme aaora aoaaa aana 13 C Communications error on lt channel name gt lt error mask gt 16 GOMn does notexist aa on Ea Pese P I Den Annes DN IU 17 COMn is in use by another application sees 17 D Data Type lt type gt is not valid for device address lt address gt _ eee eee 16 Data Types Description 0 2 9 4 alc cece cece cece K R eee Reese sees sees essere sre rre 9 Device lt device name gt is not responding 18 Device device responded with error Tag tag address Details error code 18 Device address address contains a syntax error
13. database for device lt device gt Reason Input file not found 22 Unable to generate a tag database for device device Reason Low memory resources 22 ROC Plus Error Codes 1002 ed a Pee th Ln aevi cere t Ps sem 22 hnoqe S 24 www kepware com 4 Fisher ROC Plus Serial Driver Help Fisher ROC Plus Serial Driver Help Help version 1 023 CONTENTS Overview What is the Fisher ROC Plus Serial Driver Device Setup How do I configure a device for use with this driver Data Types Description What data types does this driver support Automatic Tag Database Generation How can tags be automatically created for this driver Address Descriptions How do I address a data location on a Fisher ROC Plus Serial device Error Descriptions What error messages does the Fisher ROC Plus Serial driver produce Overview The Fisher ROC Plus Serial Driver provides an easy and reliable way to connect Fisher ROC Plus Serial controllers to OPC Client applications including HMI SCADA Historian MES ERP and countless custom applications This driver is intended for use with the following ROC Plus protocol devices ROC809 and ROC827 Note For more information on the Opcodes available in the ROC Plus protocol as well as point types and param eters refer to the device s ROC Plus Protocol User Manual www kepware com Fisher ROC Plus Serial Driver Help 5
14. dditional Explanations The following topics provide a further explanation of ROC addressing For a detailed listing of all point types access data type length and description refer to the device s ROC Plus Protocol User Manual Logical Location Details ROC Plus Point Types Binary Field BIN Example Logical Location Details Within each point type individual points are referenced by a Location or a Logical Number The Location used by ROC Plus Protocol for point types 101 to 109 is based on a physical input or output 1 0 module and point loca tion All other point types use a logical number and are simply numbered in sequence Note The L in the TLP references scheme Physical Point Numbers 1 to 160 For point types 101 through 109 there are location numbers for the field I O For the diagnostic inputs the scheme is as follows e Location Numbers 16 to 160 are assigned to field I O For example if there was an I O module in slot 1 with 4 points on it they would be points 16 through 19 e Location Numbers 0 to 15 are assigned to the system I O For example the five diagnostic points in a ROC800 Series would be 0 through 4 Logical Point Numbers O to 127 For all other point types except 101 109 the logical number is 0 to x where x is one less than the total number of points that exist for that point type For example the 16 PIDs would be logical numbers 0 through 15 Note For a detailed listing of all point types
15. eanings 9999 Disabled Signed 32 bit value bit 0 is the low bit bit 30 is the high bit bit 31 is the sign Unsigned 32 bit value bit 0 is the low bit bit 31 is the high 32 bit floating point value bit 0 is the low bit bit 31 is the high bit 32 bit value Point T ype L ogical or Point Number and P arameter Number Uses three bytes The top byte goes unused The type refers to the point type number The location logical number refers to individual points The parameter is a number assigned to each piece of data con tained in a given point type DWord TLP 557158 BIN 00001000 10000000 01100110 01100110 Point Type Example 102 10000000 Location 128 00001000 Parameter 8 The resulting TLP is 102 128 8 String ASCII string padded with spaces Date The number of seconds since Jan 1 1970 00 00 00 Date Example Date format YYYY MM DDTHH MM SS 000 2000 01 01T12 30 45 000 www kepware com Fisher ROC Plus Serial Driver Help For more information refer to Logical Location Details For more information refer to ROC Plus Point Types www kepware com Fisher ROC Plus Serial Driver Help 11 Automatic Tag Database Generation This driver makes use of the OPC server s Automatic Tag Database Generation feature When enabled this fea ture will build a list of OPC tags within the OPC server that correspond to the device s data points Automatic Tag Database Generation is configured by the setti
16. ence for further information regarding lt error code gt 2 Verify the cabling between the PC and the device 3 Confirm that all tags within this block exist on the device See Also ROC Plus Error Codes Failed to write data for PointType lt point type gt Logical Address address Parameter lt parameter gt for device lt device gt Error amp error code gt Error Type Serious Possible Cause 1 The address is incorrect 2 The unit does not support the particular address point 3 The privileges for the logged in user do not permit this operation Solution 1 Consult the ROC error code reference for further information regarding lt error code gt 2 Correct the address 3 Confirm that the address is supported by the controller in use 4 Supply an operator identification with sufficient privileges See Also ROC Plus Error Codes ROC initialization error Unable to read general configuration Error Type Serious Possible Cause The driver may not be receiving a response from the device Solution 1 Ensure the device is physically connected and powered on 2 Check that the COM port is working and configured properly at the channel level in the OPC server 3 Check the device level Operator Identification and Address Specification settings and verify that they are cor rect See Also Operator Identification Address Specification ROC initialization error Unable to retrieve
17. hat has been specified statically references a location that is beyond the range of supported loca tions for the device Solution Verify that the address is correct if it is not re enter it in the client application Data Type lt type gt is not valid for device address lt address gt Error Type Warning Possible Cause A tag address that has been specified statically has been assigned an invalid data type Solution Modify the requested data type in the client application Device address lt address gt contains a syntax error Error Type Warning Possible Cause A tag address that has been specified statically contains one or more invalid characters Solution Re enter the address in the client application Device address lt address gt is Read Only Error Type Warning Possible Cause A tag address that has been specified statically has a requested access mode that is not compatible with what the device supports for that address Solution Change the access mode in the server application Missing address Error Type Warning Possible Cause A tag address that has been specified statically has no length Solution Re enter the address in the server application Serial Communications The following error warning messages may be generated Click on the link for a description of the message Serial Communications Communications error on channel name gt lt error mask gt COMn does not ex
18. ing parameter Ending Parameter ending parameter for device device Error ROC 18 Failed to write data for PointType point type gt Logical Address address Parameter lt param eter gt for device device Error error codes 19 ROC initialization error Unable to read general configuration 19 ROC initialization error Unable to retrieve I O map 19 www kepware com Fisher ROC Plus Serial Driver Help 3 The username or password supplied was not accepted Error 6 20 The username or password supplied was not accepted Error 63 20 Write request rejected on Read Only item reference channel name gt device name gt lt address gt _ _ 20 Automatic Tag Database Generation Error Messages 20 Error importing CSV tag record record number gt Address lt Address gt is out of range for the specified device oriregistetes 2 4 22 oA Seek noose sk ll E kode eer no ric e DEF NS DOR EE eee 20 Unable to generate a tag database for device device Reason Auto tag generation 21 Unable to generate a tag database for device device Reason Failed to open recordset 21 Unable to generate a tag database for device device Reason Input file is corrupt 21 Unable to generate a tag
19. ist COMn is in use by another application Error opening COMn Unable to set comm parameters on COMn Communications error on lt channel name error mask gt Error Type www kepware com Fisher ROC Plus Serial Driver Help Serious Error Mask Definitions B Hardware break detected F Framing error E 1 0 error O Character buffer overrun R RX buffer overrun P Received byte parity error T TX buffer full Possible Cause 1 The serial connection between the device and the Host PC is bad 2 The communication parameters for the serial connection are incorrect Solution 1 Verify the cabling between the PC and the device 2 Verify that the specified communication parameters match those of the device COMn does not exist Error Type Fatal Possible Cause The specified COM port is not present on the target computer Solution Verify that the proper COM port has been selected in the Channel Properties COMn is in use by another application Error Type Fatal Possible Cause The serial port assigned to a device is being used by another application Solution Verify that the correct port has been assigned to the channel Error opening COMn Error Type Fatal Possible Cause The specified COM port could not be opened due to an internal hardware or software problem on the target com puter Solution Verify that the COM port is functional and may be accessed by other Windows app
20. lications Unable to set comm parameters on COMn Error Type Fatal Possible Cause The serial parameters for the specified COM port are not valid Solution Verify the serial parameters and make any necessary changes www kepware com Fisher ROC Plus Serial Driver Help Device Status Messages The following error warning messages may be generated Click on the link for a description of the message Device Status Messages Device device name gt is not responding Device device name is not responding Error Type Serious Possible Cause 1 The connection between the device and the Host PC is intermittent 2 The communication parameters for the serial connection are incorrect Solution 1 Verify the cabling between the PC and the device 2 Verify that the specified communication parameters match those of the device Device Specific Messages The following error warning messages may be generated Click on the link for a description of the message Device Specific Messages Failed to obtain data block for PointType point type Logical Address address Starting Parameter starting parameter Ending Parameter ending parameter for device lt device gt Error ROC error code Failed to write data for PointType point type gt Logical Address lt address gt Parameter lt parameter gt for device lt device gt Error error code gt ROC initialization error
21. ngs on the Database Creation tab in Device Properties Note For more information on specific tabs in Database Creation click Help Device Properties Tag Import Settings More Tag Import Settings Address Specification Time Synchronization perator Identification General Timing Auto Demotion Database Creation Settings Automatic tag database generation on device startup Do not generate on startup Perform the following action on previously generated tags Delete on create E Add generated tags to the following group IV Allow automatically generated subgroups Auto Create Cancel Apply Help Note For more information on importing tags from a ROCLINK project refer to Tag Import Settings and More Tag Import Settings www kepware com Fisher ROC Plus Serial Driver Help Address Descriptions Overview of ROC Addressing Format ROC addresses are divided first by Point Type then Logical Address and finally Parameter Index within the Point Type Some parameters are further broken out into individual bits The general format is as follows T L P where T is the Point Type L is the Logical Address and P is the Parameter Index Parameters that are further broken out into individual bits are addressed as follows T L P B where B is the bit offset Note For example the address 1 50 3 2 indicates the following Point Type 50 Logical Address 2 Bit Offset A
22. nto the ROC Plus device during initialization Descriptions of the parameters are as follows e User Name This parameter defines the User Name Enter three characters as set in the device Three characters are required www kepware com s Fisher ROC Plus Serial Driver Help e Password This parameter defines the Operator Password Enter four numeric characters between 0000 and 9999 e Enable Access Level When checked this parameter specifies that the ROC Plus device has defined access levels Enter the access level 0 to 5 Time Synchronization To view or change the Time Synchronization settings after the device has been added right click on the device and then select Properties Time Synchronization New Device Time Synchronization Select the method used to synchronize the ROC device s clock to the local server and the time reference to use Local Time C UTC Synchronization Method Absolute Sync Time 03 22 PM Synchronization Interval 5 minutes zd tea _ we Descriptions of the parameters are as follows e Local Time or UTC This parameter specifies Local time local to the PC on which the OPC server is installed or Universal time UTC Coordinated Universal Time e Synchronization Method This parameter specifies the method of synchronization Disabled Absolute or Interval Synchronization adjusts the ROC device clock When Disabled is selected the driver will not
23. oaoa anaran 7 OVENVIOW L EH d R ROC initialization error Unable to read general configuration 19 ROC initialization error Unable to retrieve I O map 19 ROC Plus Error Codes 22 ROC Plus Point Types 12 S Serial Communications erii b E iro odoj ioio e iroi I or oc an 16 T Tag Import Settings 5 5 s ERA ii MEI LUAM 5 The username or password supplied was not accepted Error 6 20 The username or password supplied was not accepted Error 63 20 Time Svnchronization essere enne 8 U Unable to generate a tag database for device device Reason Auto tag generation 21 Unable to generate a tag database for device device Reason Failed to open recordset 21 Unable to generate a tag database for device lt device gt Reason Input file is corrupt 21 Unable to generate a tag database for device device Reason Input file not found 22 Unable to generate a tag database for device device Reason Low memory resources 22 Unable to set comm parameters on COMn 17 W Write request rejected on Read Only item reference channel name gt device name 20 www kepware com
24. ort Settings and More Tag Import Settings tabs Review the settings and check the import file If necessary re export the project file from within ROCLINK800 See Also Tag Import Settings More Tag Import Settings Automatic Tag Database Generation www kepware com 2 Fisher ROC Plus Serial Driver Help Unable to generate a tag database for device device Reason Input file not found Error Type Warning Possible Cause The Automatic Tag Generation import file cannot be found Solution In the OPC server project right click on the device and then select Properties from the context menu In the Device Properties dialog click on the Tag Import Settings and More Tag Import Settings tabs and check the name of the project file that will be imported See Also Tag Import Settings More Tag Import Settings Automatic Tag Database Generation Unable to generate a tag database for device device Reason Low memory resources Error Type Warning Possible Cause The memory required for Automatic Tag Generation could not be allocated The process is aborted Solution Close any unused applications and or increase the amount of virtual memory Then try again ROC Plus Error Codes Note regarding Opcode 255 Opcode 255 is an error message indicator that returns an error code multiple parameters Some of these may be Read Only and some may not www kepware com Fisher ROC Plus Serial Driver Help 23 Illeg
25. ot re enter it in the file being imported Unable to generate a tag database for device device Reason Auto tag gen eration Error Type Serious Possible Cause 1 The connection between the device and the Host PC is intermittent 2 The communication parameters for the serial connection are incorrect Solution 1 Verify the cabling between the PC and the device 2 Verify that the specified communication parameters match those of the device Unable to generate a tag database for device device Reason Failed to open recordset Error Type Warning Possible Cause 1 The project file is corrupt or does not exist 2 Locations for the ROC MDB and or ROCLINK MDW files have been specified incorrectly Solution In the OPC server project right click on the device and then select Properties from the context menu In the Device Properties dialog click on the Tag Import Settings and More Tag Import Settings tabs and check the name of the project file that will be imported See Also Tag Import Settings More Tag Import Settings Automatic Tag Database Generation Unable to generate a tag database for device device Reason Input file is corrupt Error Type Warning Possible Cause The Automatic Tag Generation import file is corrupt Solution In the OPC server project right click on the device and then select Properties from the context menu In the Device Properties dialog click on the Tag Imp
26. perform time synchronization When Absolute is selected the driver will perform time synchronization once daily at the time specified in Absolute Sync Time When Interval is selected the driver will perform time synchronization every x minutes The default set ting is Disabled e Absolute Sync Time This parameter specifies the time at which the driver will perform time syn chronization each day e Synchronization Interval This parameter specifies the synchronization interval in minutes The driver will perform time synchronization every x minutes Modem Setup This driver supports modem functionality For more information please refer to the topic Modem Support in the OPC Server Help documentation www kepware com Fisher ROC Plus Serial Driver Help 9 Data Types Description EET Boolean Single bit Signed 8 bit value bit 0 is the low bit bit 6 is the high bit bit 7 is the sign bit Unsigned 8 bit value bit 0 is the low bit bit 7 is the high bit Signed 16 bit value bit 0 is the low bit bit 14 is the high bit bit 15 is the sign Unsigned 16 bit value bit 0 is the low bit bit 15 is the high bit Point Type 100 parameters 3 5 are HOURMINUTE This driver represents HOURMINUTE this data type as Word Length 2 Bytes Time is listed as a decimal based number The first two digits represent the hour and the last two digits represent the minute Range 9999 0 23 for 2 MS Digits 0 59 for 2 LS Digits Special M
27. re provided with the ROCLINK 800 application Address Specification To view or change the Address Specification settings after the device has been added right click on the device and then select Properties Address Specification www kepware com Fisher ROC Plus Serial Driver Help New Device Address Specification I Determine the Host Group Number Host Unit Number Destination ROC Group Number and Destination ROC Unit Number The Destination is the remote ROC device The Host is the server address Host ROC Unit Host ROC Group L Destination ROC Unit 240 Destination ROC Group 240 Lg tv k ao d Help Enter the Host ROC Unit Host ROC Group Destination ROC Unit and Destination ROC Group values The valid range for these fields is 1 through 255 Operator Identification To view or change the Operator Identification settings after the device has been added right click on the device and then select Properties Operator Identification New Device Operator Identification Set the operator identification username and password used to login to the ROC during initialization If Access Level Control is enabled on the ROC check the box and enter the desired access level UserName 189 Password F v Enable Access Level 2 caen _ we This dialog is used to specify the operator identification values User Name and Password which will be used when logging i