1. Before using a specific compound ensure that it is the right reagent read the label a few times Never return the leftover of the products to the jar When disposing of any reagent ensure that circulate enough water on the sink Do not touch with your hands not with the mouth chemical products If so check the manual contingency measures The acids require special care When required to dilute them never add water over them on the contrary dilute it in a water layer Flammable products should not be near heat sources such as heaters stoves heaters burners etc When any chemical spill you must act quickly but without haste Once you finish the practice return the reagent bottles back to their storage place and remove the waste according to the rules of this manual HAZARDOUS CHEMICALS The chemicals are classified according to their dangerousness in Explosives Substances and preparations which may explode under the effect of flame Oxidising Substances and preparations which in contact with others particularly with flammable ones cause a highly exothermic reaction Extremely flammable Substances and chemical products whose flash point lower than O C and boiling point 35 C or less 10 Highly flammable are defined as such e Substances and preparations which at room temperature in air and without energy supply may get hot and even catch fire e Liquid substances and preparations with a flash point
2. See a doctor to continue the treatment Spillover Directly inactivate with chlorine undiluted by 15 20 min Wipe with an absorbent material and dispose of it in the red bag Finally clean the area with 70 alcohol 12
3. at 15 psi you must take the time For proper sterilization 15 30 minutes must pass Once the time finish turn off the power 8 Once the barometer indicates zero psi open the control valve and loose fasteners 9 Lift up the lid and take out the material using thermal gloves Ill Laminar flow cabinet 1 Before working disinfect the entier work sufrace with 7096 alcohol 4 2 Turn on the laminar flow at least 15 minutes before start work 3 You must work with gloves and spray your hands with 70 alcohol every time you take them out of the cabinet 4 Place inside the cabinet only the material that is useful and needed for the work such material should be disinfected with 7096 alcohol before introduce it into the work area 5 Remove the material you no longer use Disinfects the material before take it out of the cabinet with 70 alcohol 6 When you finish working clean the work area and disinfects the table using 70 alcohol 7 Be sure to turn off the laminar flow and light 1 UV on 2 UV off 3 Light on 4 Electricity on 5 Electricity off 6 Laminar flow on 7 Laminar flow off 8 Barometer IV Proper use of micropipettes 1 Make sure you choose the right pipette for the volume needed Exceeding the maximum volume or forced to a lower value of the minimum damage and decalibrate the micropipette 2 When you put a tip make sure that is not loose caus this will allows the enter of air and the volume will no
4. at or above O C and below 21 C e Solid substances and preparations which may easily igntite because of brief contact with a source of ignition and which continue to burn or to be consumed after removal of the fire source e Gaseous substances and preparations which are flammable in air at normal pressure e Substances and preparations which in contact with water and damp air release flammable gasses in dangerous quantities Flammable Substances and preparations having a flash point equal to or greater than 21 C and below 55 C Very toxic Substances and preparations which by inhalation ingestion or skin penetration may involve serious acute or chronic health risks and even death Harmful Substances and preparations which by inhalation ingestion or skin penetration involve risks of limited severity Corrosive Substances and preparations which in contact with living tissue can have a destructive action on them Irritant Non corrosive substances and preparations which through immediate prolonged or repeated contact with the skin or mucous membrane may cause inflammation Environmental hazards Substances and preparations which use present or may present immediate or delayed risks for the environment Carcinogens Substances and preparations which by inhalation ingestion or skin penetration can cause cancer or increase its frequency Teratogenic Substances and preparations which by inhalation ingestion or skin penetratio
5. balance 1 You need to register in the journal before using the balance and write in the same if an abnormality is observed in the equipment before or after use it if so notify the manager 2 Never weigh directly on the weighing plate Always use filter paper or watch glas 3 Make sure the instrument is calibrated before use it 4 You should avoid any disruption leading to an error such as vibration due to hitting running instruments or blowing on the plates of the scale 5 Wash the spatula before and after use with tap water and dry it with paper 6 Once the balance is used the equipment must be clean and off HANDLING AND CARE OF LABORATORY EQUIPMENT Within the research laboratories and Biomedicine you will find equipment that need proper management as well as some care to keep them running properly In this section you will find basic rules for handling the most commonly used equipment in the laboratory as well as links to the manuals and the person in charge of its management Before using any equipment 1 Learn about the uses and limitations of each of the instruments 2 Read the user s manual 3 Contact the person in charge of the equipment in case you have doubts about its use 4 If itis the first time the equipment is used to do it in the presence of someone trained 5 The samples must be prepared according to the equipment requirements in order to avoid disadvantages when it used Avoid putting in substance
6. INSTITUTO TECNOLOGICO Y DE ESTUDIOS SUPERIORES DE MONTERREY CAMPUS CHIHUAHUA LABORATORY MANUAL For Biotechnological Engineering Students Writted by Biotechnology Committee M C Carmen Daniela Gonzalez Barriga M C Carmen Maldonado M C Carlos Arzate Quintana M C Cynthia Lizeth Gonzalez Trevizo M C Silvia Lorena Montes Fonseca M C Yazmin Rocio Reyes Cortez Translated by iGEM Tec Chihuahua Chihuahua Chih July 2013 GENERAL REGULATIONS FOR LABORATORY USE 1 In order toenter the lab you must wear a long sleeve lab coat pants to the ankle closed foot wear and have the hair tied 2 Remember to wash your hands before and after you work on the lab 3 Wear properly the personal protective equipment PPE like latex gloves protection glases mask as warrants to conduct the experiment 4 Remain inside the lab until you finnish the experiment and or your teacher indicate it Avoid entering and getting out unless it be really necessary 5 Remaining in the laboratory is allowed only to persons whose activity requires it 6 Be sure of not have any cuts scrapes and other skin injuries if so cover the injury as it be convennient to avoid any kind of contact with material and lab reagents 7 Keep your belongings outside the work area this includes the floor you ocupate for working 8 Make sure of keep the work area clean and ordered before and after you work 9 If it is necessary work near the flame of the bunsen burn
7. er or inside the laminar flow cabinet according to the bio safety level needed for the experiment 10 Food drinks yelling running playing and sitting on the tables of in the floor its prohibited inside the lab 11 The use of celphones or any kind of electronic deviche is prohibited inside the lab 12 It is strictly forbidden to take away 12 It is strictly forbidden to take away any kind of lab equipment reagents cultures samples problem if the instructor not tells you to do so 13 Before pouring any type of solid or hazardous substances in the laboratory sink check your MSDS or ask your instructor 14 If you detect anomalies on the lab or in the laboratory equipment please report it to your instructor 15 If you are going to use some lab equipment be sure to follow the instructions of the equipment s manual register in the journal and notify your instructor If you have any doubt he will guide you 16 Is responsibility of all users to keep clean and tidy the lab so before leaving you need to make sure you have correctly rejected the reagents no longer going to use wash your gear and leave your work area clean and orderly 17 Es important that all the material you use is perfectly labeled including name of the reagent material preparation date your full name and subject or project for which you are using LABORATORY EQUIPMENT DESCRIPTION I Autoclave Tuttnauer 2340 manual model Heidolph Brinkman gt Tutt
8. n can induce lesions in the fetus during its intrauterine development Mutagenic Substances and preparations which by inhalation ingestion or skin penetration may cause alterations in the genetic material of cells Some of these substances appear in the labeling of chemicals by a symbol or pictogram Explosive Oxidizer Toxic Irritant Flammable Corrosive 11 USE AND HANDLING OF HAZARDOUS BIOLOGICAL INFECTIOUS WASTE It is a Hazardous waste any material of biological origin blood urine sputum feces tissue cell culture bacterial and vegetables Hazardous waste disposal will be as follows Red bag petri plates previously sealed with parafilm gloves dressing material containers which have been in contact with hazardos waste Plastic red conainter for sharps syringe needles slides cover slips glass pieces lancets etc Plastic red container for liquids blood Plastic yellow container for liquids urine agarose and polyacrylamide gels Yellow bag tissue and organs animals Note Both the bags and the boats must not exceed 80 of its capacity Do not forget to always use personal protective equipment to use or transport hazardous waste Hazardous biological infectious waste contingencies Splashes on the skin wash with soap and water and disinfect the area with 70976 alcohol Splashes in the eyes wash with water and see a doctor immediately Puncture Wash with soap and water and disinfect the area with 70 alcohol
9. nauer Y The instruments consists of five basic controls 1 Barometer indicates the pressure inside the chamber of the autoclave 2 Timer indicates for how long the autoclave will be working 3 Thermostat lets you select the temperature range within the autoclave s camera 4 Select function selects the mode in which youll be working the autoclave 5 On off turns on and off the autoclave Using Manual autoclave Tuttnauer Model 2340 1 Make sure the autoclave is perfectly leveled before puring the water 2 Wash the material according to the lab protocol before placing it in the tray of the autoclave 3 Place on the tray the material to be sterilized Do not exceed the limit of 3 2 kg of material and do not place media bottles with liquid or horizontally to prevent spills 4 If put bottles or tubes with screw cap be sure to leave the lid slightly loose otherwise sterilization will not be efficient The volume should not exceed two thirds of the volume of the bottle to prevent spillovers 5 If you place packages be sure to leave space between them the material should not touch the walls of the equipment 6 Fill the chamber with 400ml distilled deionized distilled water closes the door and select the option FILLING 7 Close the door turning the crank 8 Place the thermostat to the desired temperature 115 C 9 Place the timer 30 45 minutes for packages and instrumental and from 45 60 minutes for liq
10. s that can damage the equipment 6 In case of any problem in the use of any equipment please report it to the nearest authority and the person in charge of the equipment 7 Always register you in the journal of each equipment 8 Once you have finish turn off and clean the equipment In case the equipment has adicional pieces keep them in place Investigation Laboratory Equipment EQUIPMENT Model Brand Eigse al sane All American 25X 1 serie Carlos Arzate ectrical autoclave ever da Carmen D Centrifuge Eppendort Eppendorf 5804R Gonz lez D Centrituge Galaxy Galaxy 20r VWR o Refrigerator 20 C Marvel Scientific 17 CAF Incubator Silvia L Montes Symphony VWR Fonseca l Refrigerator 4 C Torrey R 14 Bu Pionner Ohaus Yazmin Reyes Agilent Technologies Thermocycler Carmen D Gonzalez Sure Cycler 8800 Eppendorf Master Cycler Termobloock Personal Silvia L Montes Fonseca Eppendorf Thermomixer Carmen Daniela Thermomixer compact Gonz lez Bouble boiler Cynthia Gonz lez Carlos Arzate Optical microscope PrimoStar Carl Zeiss Quintana thi al Thermo Scientific Cimarec UU on Biomedicine Laboratory Equipment ilvia L Mont Inverted microscope Olympus PME3 nua US Fonseca tronic 20D Th peewee 7 E i o scientific Sheldon Manufacturing H2O Cynthia Gonzalez series Bouble boiler Agilent 2100 Agilent ilvia L Mont Technologies vitiis abet Fonseca Bioanalyzer Agilent S
11. t be right Do not hit the tip of the micropipette 3 Before taking the fluid presses the plunger and take it to the first stop without going over Insert the tip into the liquid and release the plunger Your tip and should be loaded with the desired volume 4 To release the liquid place the tip on the wall of the desired container unless the methodology recommended it in another way and gently press the plunger to the second stop Push too quickly or hard can cause splashing the contents 5 Never put the pipette in an inclined or horizontal position when making sample as this will contaminate or damage the micropipette as well as causing changes in the volume obtained 6 For viscous liquid filling and expulsion should be slower 7 Avoid using a micropipette with corrosive solvents 8 The ideal temperature for handling liquids with the pipette is 15 to 40 C 9 When not in use avoid placing the pipette in a horizontal position for extended periods of time as this will affect their calibration 5 10 Avoid dropping or bumping the pipette and place it in unstables position or surfaces 11 If you need to adjust the volume of the pipette do it gently and turn the volume control too vigorously or quickly you can damage it 12 When finished using a micropipette be sure to adjust it to the maximum volume allowed cause leave it at lower values for long periods of time will eventually decalibrate it V Use and management of
12. tratagene Mx3005p D Agilent Technologies palle Thermocycler qPCR Gonz lez Optical microscope Carlos Arzate P j Primo Star Carl Zeiss Lnd C D Fotodocumentador UVP BioDoc it 210 Imaging B System UV Vis Beckman Coulter SU730 Life Spectrophotometer Science Lucia Olivas Silvia L Montes Axio Vert A1 Carl Zeiss Fonseca TerLab Cynthia Gonzalez Symphony VWR 3074 Em Refrigerator 20 C VWR NorLakescientific Autoclave AESA modelo CV300 Carlos Arzate Gonz lez Inverted microscope Refrigerator 80 C LABORATORY REAGENTS The reagents must be stored as the NOMO 053 ECOL 1993 indicates It is madatory to wear personal protective equipment gown gloves and security glasses The student must be familiar with the handling and transportation of hazardous waste Corrosive highly reactive toxic flammable explosive etc The arrangement of reagents and solvents will be controlled and safe according to the manual In case of preparing a reagent place it in a storage jar properly labeled with the following information Name and full chemical formula concentration of solution Molarity and Normality as applicable reagent preparation date and the name of the person who elaborate i it It is strictly forbidden to pipette reagents with the mouth always use a propipeter When working with highly toxic substances is necessary to use a protective mask and work inside the fume extraction cabinet
13. uids 10 Turn the knob and place it in sterilized and make sure the indicator lights 11 Once you have completed the sterilization wait till the barometer indicates zero psi Then move the function knob on dry and placd the timer in 20 or 30 minutes All the material is dried except liquids Before opening the door make sure the pressure has dropped completely 12 Open the door and remove the material using thermal gloves Il Manual Autoclave model Allamerican 25X R 3 Pa E 3 o od 1 Use distilled deionized distilled water to fill the chamber to the tray level of and place the aluminum container inside the chamber of the autoclave 2 In case you put bottles or tubes with screw cap be sure to leave the lid slightly loose and place them horizontally avoided The volume should not exceed two thirds of the volume to avoid spillovers 3 In case of placing packages be sure to leave space between them the material should not touch the walls of the aluminum container 4 Place the lid making sure to place the exhaust air duct inside the aluminium container wall Level the lid before closing the fasteners closing them in opposite pairs at the same time 5 Place the control valve in the open position until it begins to release steam then you must turn it in the closed position 6 Monitor the pressure and temperature until it reaches 15 psi Adjust the thermostat to avoid excessive pressure 7 Once
Download Pdf Manuals
Related Search
Related Contents
醸imati0n Avida-ED User Manual PT580 Digital Vibration Switch User Manual Digital Ears Manual NA1550 instruction manual AV-28RT4BU AV-28RT4SU ALPHASENSE USER MANUAL LED CO2 NDIR Sensor Evaluation Kit South Shore Furniture 3746027 Instructions / Assembly Artigo sobre Processadores Copyright © All rights reserved.