1. 34 COMPARING METER AND LABORATORY RESULTS The result you obtain from your meter may differ somewhat from your laboratory result due to normal variation Meter results can be affected by factors and conditions that do not affect laboratory results in the same way See test strip package insert for typical accuracy and precision data and for important information on Limitations To make an accurate comparison between meter and laboratory results follow the guide lines below Before you go to the lab e Perform a control solution test to make sure that the meter is working properly e It is best to fast for at least eight hours before doing comparison tests e Take your meter with you to the lab While at the lab Make sure that the samples for both tests the meter test and the lab test are taken and tested within 15 minutes of each other e Wash your hands before obtaining a blood sample e Never use your meter with blood that has been collected in a gray top test tube e Use fresh capillary blood only 35 amp Oracle You may still have a variation from the result because blood glucose levels can change significantly over short periods especially if you have recently eaten exercised taken medication or experienced stress In addition if you have eaten recently the blood glucose level from a finger stick can be up to 3 9 mmol L higher than blood drawn from a vein venous sample used for a lab test Therefore
2. EP Oracle ao Glucose Monitoring System GMH B1 GMH B2 Ver 1 3 Owner s Manual F AV ay a Oracle Dear EZ Health Oracle GMH B1 B2 System Owner This manual contains important information you must know about the system Please read it thoroughly and carefully The greatest feature of this system is its Bilingual Speaking Function wD which is an acoustic aid for users especially with visual disability Please note that this function is optional If the meter does not have wD it will not provide speaking function Another unique feature is its Autocode function which means there is no need to calibrate your meter and allows you to easily monitor your blood glucose at home The system is intended for use outside the body in vitro diagnostic use It should be used only for testing glucose sugar and only with fresh capillary whole blood samples The system is intended for use in the home and in clinical settings It should not be used for the diagnosis of diabetes or the testing of newborns An audio version of the owner s manual is available on the enclosed CD or on our website at www oraclediabetes com or by calling one of our friendly representatives at 866 829 7926 IMPORTANT SAFETY INSTRUCTIONS PLEASE READ THIS BEFORE USING The following basic safety precautions should always be taken Close supervision is necessary when the device is used by on or near children or handicapped pe
3. amp and J will appear In the meantime you can choose to insert a test strip to start testing your blood or press the M button again to review the stored test results N A mmollL ca cam CALM If no button is pressed for 2 minutes the meter will show OFF and turn off automatically 40 Viewing Results on a Personal Computer Results in memory can be transmitted to a personal computer An Interface Cable is required for data transmission but is not included Please ask your local agent or call toll free 866 829 7926 for help The software is available on the enclosed CD or can be downloaded from www oraclediabetes com To learn more about EZ Health Diabetes Management Software or to obtain an Interface Cable separately please contact your local customer service Step I Installing Software Install EZ Health Diabetes Management Software on your computer by following the instructions provided in the user manual included on the CD or on EZ Health s website www oraclediabetes com Step 2 Connect to Personal Computer Connect the interface cable to the serial port in your computer With the meter turned off connect the Interface Cable to the Data Port of the meter PC will appear on the display indicating that the meter is ready to transmit data ey Oracle uw 4 Step 3 Transmit Data Follow the instructions provided i
4. it is best to fast for eight hours before doing comparison tests Factors such as the amount of red blood cells in the blood a high or low hematocrit or the loss of body fluid severe dehydration may also cause a meter result to be different from a laboratory result References 4 Surwit R S and Feinglos M N Diabetes Forecast 1988 April 49 51 5 Sacks D B Carbohydrates Burtis C A and Ashwood E R ed Tietz Textbook of Clinical Chemistry Philadelphia W B Saunders Company 1994 959 36 7 USING THE METER MEMORY View Results on the Meter Your meter stores the 450 most recent blood glucose test results with date and time in its memory It also provides you with 7 14 21 28 60 and 90 day averages of your blood glucose test results You can review the test results in the memory with these easy steps STEP I Enter the Memory Mode With the meter turned off press the M button twice The 7 day average will appear indicating that you are in the memory mode If you continue to press the M button the 14 21 28 60 and 90 day average will appear in order You can then review the last 450 tests in the memory When using the meter for the first time appears showing that there are no test results in memory The 7 day average is calculated from the blood glucose results obtained during the last 7 days It also indicates how many blood glucose tests have been performed within this per
5. relax during measurement The room temperature is number degree Celsius Fahrenheit Room temperature is out of range thus unable to measure Please apply blood into the strip Your blood glucose is number Millimole per Liter The blood glucose is out of range thus unable to measure 5O ka Oracle Appearance of the Test Strip Your system measures the amount of sugar glucose in whole blood Blood is applied to the absorbent hole of the test strip and is automatically drawn into the reaction cell where the reaction takes place The test strip consists of the following parts Contact Bars Insert this end of the test strip into the meter Push it in firmly until it will go no further Test Strip Handle Hold this part to insert the test strip into the slot Confirmation Window This is where you confirm if enough blood has been applied to the absorbent hole of the strip Absorbent Hole Apply a drop of blood here The blood will be drawn automatically See pages 27 33 Testing Your Blood for complete instructions PREPARATION BEFORE USE Battery Replacement Your meter comes with two 5V AAA size alkaline batteries The meter will alert you when the power is getting low by displaying two different messages The symbol appears together with other display messages the meter is functional and the result remains accurate but it is time to
6. tightly e Touch the test strip with clean and dry hands 44 e Use each test strip immediately after removing it from the vial e Write the discard date the date opened plus 90 days on the vial label when you first open it Discard remaining test strips 90 days after first opening date e Do not bend cut or alter a test strip in any way e Keep the strip vial away from children since the cap may be a choking hazard If swallowed promptly see a doctor for help 3 Control solution storage e Storage condition Store the control solution tightly closed at temperatures below 30 C 86 F Do not refrigerate e Record the discard date date opened plus 90 days on the control solution vial Discard after 90 days 45 ka Oracle PROBLEM SOLVING GUIDE Following is a summary of some display messages and symbols These messages help to identify certain problems but do not appear in all cases when a problem has occurred Improper use may cause an inaccurate result without producing an error message or a symbol In the event of a problem refer to the information under action Never try to disassemble the meter in any circumstances If you encounter any error messages not listed below or if you have followed the actions recommended below but the problem remains unsolved please call the customer service for support 46 Result Indicator Special symbols and messages appear together with
7. 0 104 F Repeat the test after the meter and test strip have reached the above temperature Re test with a new test strip Review the instructions and re test with a new test strip If the above steps do not work please contact your local Customer Care Line at 866 829 7926 for help Problem in Operation If the meter does not display a message after inserting a test strip PROBABLE CAUSE WHAT TO DO Battery incorrectly Check that the battery is correctly installed or absent installed Test strip inserted upside Insert the test strip correctly with the down or incompletely contact bars end first and facing up Defective meter Please call your local Customer Care Line at 866 829 7926 for help 2 If the test does not start after applying the sample PROBABLE CAUSE WHAT TO DO Insufficient blood sample Repeat the test with a new test strip and a larger sample Defective test strip Repeat the test with a new test strip Sample applied after automatic Repeat the test with a new test strip apply shutoff 3 minutes after last user sample only when appears on the display action Defective meter Please call your local Customer Care Line at 866 829 7926 for help 49 Oracle 3 If the control solution test result is out of range PROBABLE CAUSE WHAT TO DO Error in performing the test Read the instructions thoroughly and repeat the test again Did not shake the cont
8. 7926 for help Appearance and Key Function of the Meter TEST SLOT cevcesccesceseseseseeeseeeeeeees The test slot is where you insert the test strip for testing The meter will turn on automatically when you insert a test strip DISPLAY 000 0 0eseseseessceeeeseeeseeeeeees Your test results are displayed here The large easy to read display guides you through the test using symbols and simple messages MAIN BUTTON The main button in front of the meter is used to set up the meter enter the memory mode change the value of date time unit setting memory deletion and turning the meter on and off TALKING SYMBOL Indicates that the meter contains speaking function SET BUTTON in the back Set the date time and unit located in the battery compartment Q Avdliva DATA PORT Located at the side is for cable connection to the computer G Oracle Meter Display Segments Test Strip Symbol Appears when the meter is On s0 Blood Drop Symbol This symbol tells you when to apply the sample seee Temperature Symbol Appears with ambient temperature after inserting a test strip gessusaticsisasdaeatersacess 7 Face Symbol low high Symbol Both are result indicators Face low symbol appears when test result is between 1 1 to 3 9 mmol L ees Face high symbol appears when test result is greater than 10 0 mmol L
9. Date Time CTL Symbol EEEE Pi i Appears when the test result Appears when performing a control solution test and indicates that the result will not be stored in the memory Day Average 5 Indicates that the displayed test result is an average 12 Test Result Area Test results are displayed here 1 f Voice Symbol Indicates speaking function is i on off i Battery Symbol Appears when the battery is low Measurement unit j Appears with the test result in mmol L Ketone Warning Appears when the test result is equal or higher than 13 3mmol L Smile Symbol is within reference range Memory Symbol Appears when you review the memory Speaking Function When the talking symbol u is on the meter it means that the meter provides speaking function It speaks step by step and leads you through a blood glucose test The following table tells you when and what the meter speaks WHEN WHAT does the meter say does the meter speak When meter is turned on When room temperature is detected When room temperature is outside operating range When the meter is ready to test symbol appears on display When the test is completed The result appears on display When the test result is outside measurement range which is 1 1 to 33 3 mmol L Welcome music plays Thank you for using this product Please
10. blood from sites other than the finger replace the lancing device cap with the clear cap Turn the clear cap until it is snug but not too tight and then Slide the ejection cocking control back until it clicks The lancing device is now ready for use Set aside for later use STEP 2 Insert the Test Strip Insert a test strip with contact bars end first and facing up into the test slot The meter turns on automatically and displays the following in sequence ao CH and amp _ gt ambient temperature date time and flashing 6 Ea a 30 STEP 3 Get a Drop of Blood Before collecting a drop of blood e Wash and dry your hands before you start Select the puncture site either at the fingertip or another part of the body e Rub the puncture site for about 20 seconds before penetration e Clean the site using cotton swab moistened with 70 alcohol and let it air dry e For collecting blood samples from sites other than the fingertip use the clear cap Lancing the finger Press the EZ Health Oracle lancing device s tip firmly against the lower side of your fingertip Press the release button to prick your finger A click indicates that the puncture is complete Sites other than fingertip Please refer to the section of About AST for available puncture sites Remove the device from the puncture site After penetration remove the first drop of bl
11. change the batteries 2 The symbol appears with the flashing _bL E b symbol and low the batteries can not provide enough power to do a test You must change the batteries immediately PLEASE NOTE e Replacing the batteries does not affect the meter s memory previous test results stored in memory However the time and date settings may need to be updated e Batteries might leak chemicals if not used for a long time Remove the batteries if you are not going to use the device for an extended period i e 3 months or more L5 eye T sa Oracle To replace the batteries make sure that the meter is turned off l Press the buckle on battery cover and lift up to remove cover 2 Remove the old batteries and replace with two new 1 5V AAA size alkaline batteries 3 Close the battery cover If the batteries are inserted correctly you will hear a beep As with all small batteries the batteries should be kept away from small children who still put things in their mouths If they are swallowed promptly see a doctor for help 16 Setting the Meter and Deleting the Memory Year month date time unit of temperature memory deletion speaking volume and language selection preset However if you replace the batteries you may need to reset the settings of the meter Start with the meter off Then press the Set button located in the battery compartment The meter is now in the sett
12. dEL with flashing M symbol 7S ka Oracl Sr hes cre STEP 7 Delete the Memory When dEL and blinking M symbol is displayed if you do not want to delete memory press the Set button again to skip this step If you would like to delete ALL memory press button both dEL and will flash Press the M button again to delete ALL memory and M are displayed on the meter following means that all data stored are deleted The memory of this meter is empty now JEL IdELL 1 If your meter has a talking symbol we on it please press the Set button to proceed to the next step If not you have completed the setting mode Press the Set button to turn off the meter OFF is displayed before shut down PLEASE NOTE The above settings can ONLY be changed in the setting mode Therefore when you perform a glucose testing those parameters are not possible to be changed Your meter displays 7 14 21 28 60 and 90 day averages which you can access from the meter memory These averages are calculated from results obtained during the 7 14 21 28 60 and 90 day preceding the current date and time settings When the date and time are changed the 7 14 21 28 60 and 90 day averages may change e While the meter is in the setting mode if no button is pressed for 3 minutes the meter will turn off automatically The memory of t
13. ely to make sure you get accurate results When should the control solution test be performed e Whenever you suspect that the meter or test strips are not working properly e When your blood glucose test results are not consistent with how you feel or when you think your results are not accurate e When your test strips are exposed to extreme environmental conditions See Storage section of this manual e When you want to practice running the test e If you drop the meter 22 Important Control Solution Information e Use only EZ Health Oracle or Autocode control solutions e Check the expiration date on the control solution vial Do not use if expired e Control solution meter and test strips should come to room temperature 20 25 C 68 77 F before testing e Shake the vial discard the first drop of control solution and wipe off the dispenser tip to ensure a good sample and an accurate result e Use only for 90 days after first opening Record the discard date date opened plus 90 days on the control solution vial Discard after 90 days Store the control solution tightly closed at temperatures below 30 C 86 F Do not refrigerate PLEASE NOTE The control solution range printed on the test strip vial is for EZ Health Oracle or Autocode control solution only It is used to test meter and test strip performance It is not recommended range for your blood glucose level It is not the recommended range
14. er share a lancet or the lancet device with anyone e Always use a new sterile lancet Lancets are for single use only e Avoid getting hand lotion oils dirt or debris in or on the lancets and the lancet device 27 Oracle Siu Testing Procedure WASH AND DRY YOUR HANDS FIRST BEFORE STARTING The EZ Health Oracle lancing device offers you 5 depths of skin penetration Shallow Soft or thin skin 3 Thick or calloused skin The longer the length of the indicator line the greater the depth of penetration Deep STEP Setting up the EZ Health Oracle lancing device A Twist and pull off the cap of the EZ Health Oracle lancing device A Insert a lancet into the lancet holder and push down firmly until it is fully secured Twist the protective disk off the lancet 28 Replace the cap by aligning the arrow on the cap with the release button and then push and turn the cap Select the depth of penetration by turning the adjustable tip in either direction so that the arrow on the cap points to the desired depth Pull the cocking control back until it clicks You will see a color change inside the release button when it is ready If it does not click the device may have been cocked when the lancet was inserted 29 Oracle Blood from sites other than the fingertip A clear cap included with the kit makes it easier to get a drop of blood for AST When you want to obtain
15. ff Place the protective disk on a hard surface and push the exposed tip into the disk Slide the ejector forward to remove the used lancet Dispose of the lancet according to your local regulations The used lancet and the used test strip may potentially be a VI biohazard Please discard it carefully according to your local regulations Ore ST 6 lt Oracle Expected Test Results Blood glucose monitoring plays an important role in diabetes control A long term study showed that keeping blood glucose levels close to normal can reduce the risk of diabetes complications by up to 60 3 The results you get with the EZ Health Oracle system can help you and your healthcare professional monitor and adjust your treatment plan to gain better control of your diabetes Time of day Glucose range for Your target range people without mmol L diabetes Fasting and before meal 4 0 7 0 mmol L mmol L 2 hours after 5 0 10 0 mmol L 5 0 8 0 mmol L if AIC meals targets not being met mmol L Source CDA Clinical Practice Guidelines 2008 Treatment goals should be tailored to the individual Glycemic targets for children less than or equal to 12 and pregnant women differ from these targets 3 American Diabetes Association position statement on the Diabetes Control and Complications Trial 1993 Please work with your health care professional to determine a target range that works best for you
16. for your blood glucose level 23 CY Ata rITS G Oracle Performing a Control Solution Test STEP I Insert the Test Strip Insert a test strip with contact bars end first and facing up into the test slot The meter turns on automatically and displays the followings in sequence CH and ambient temperature date time and flashing 6 Contact bars must be inserted all the way into the meter or you may get an inaccurate test result e Every time you perform a control solution test you must enter into the CTL test mode so that the test result will not be stored in the meter memory Failure to do so will confuse the blood glucose test result with the control solution test result in memory 24 STEP 2 Press the M button While the 6 symbol appears on the display press the M button and then CTL will appear on the display With the CTL sign on the display the meter will not store your test result in memory If you decide not to perform a control solution test press the button again and the CTL sign will disappear STEP 3 Obtain Control Solution Shake the control solution vial well Remove the cap Squeeze the vial discard the first drop and wipe off the dispenser tip to prevent contamination Squeeze the vial again to get another drop and place the drop on your fingertip first Gr 25 orac 6 l
17. his meter is now empty 20 STEP 8 Select Speaking Function The meter displays VOL dI and flashing number Press the M button to select speaking volume from 0 to 7 Then press the Set button to proceed to the next step Number 0 indicates that the speaking function is turned off where i does not display on LCD during testing Number to 7 indicates speaking volume from low to high where QI displays on LCD during testing qi L I STEP 9 Select Languages LI L2 and KI display on LCD Your monitor can speak in one of two languages Press the button to select Select LI for English L2 for French On some models select L3 for Italian L4 for Portuguese The setting model is all completed Press the Set ri m m button to turn off the meter OFF is displayed before Lu shut down The setting is completed Congratulations You have finished setting your meter 21 ka Oracle BEFORE TESTING Checking with EZ Health Oracle or Autocode Control Solutions EZ Health Oracle and Autocode control solutions contain a known amount of glucose that reacts with test strips By comparing your control solution test results with the expected range printed on the test strip vial label it is able to check that the meter and the test strips are working together as a system and that you are performing the test correctly It is very important that you do this simple check routin
18. information 1 Kahn R and Weir G Joslinis Diabetes Mellitus 3th ed Philadelphia Lea and Febiger 1994 489 2 Krall L P and Beaser R S Joslin Diabetes Manual Philadelphia Lea and Febiger 1989 261 263 6 ee ABOUT ALTERNATIVE SITE TESTING AST Important There are limitations for doing AST Please consult your healthcare professional before you do AST What is AST Alternative site testing AST means that people use parts of the body other than fingertips to check their blood glucose levels This system allows you to test on the palm the forearm the upper arm the calf or the thigh with the equivalent results to fingertip testing F What s the advantage D Fingertips feel pain more readily because they are full of nerve endings receptors At other body sites since nerve endings are not so concentrated you will not feel as much pain as at the fingertip When to use AST Food medication illness stress and exercise can affect blood glucose levels Capillary blood at fingertip reflects these changes faster than capillary blood at other sites Alternative site results may be different from fingertip results when glucose levels are changing rapidly e g after a meal after taking insulin or during or after exercise Therefore when testing blood glucose during or immediately after a meal physical exercise or after taking insulin take blood sample from your finger only We strongly rec
19. ing mode You can start to set up the meter STEP I Set the Year The year will appear first with the year segment flashing Press and release the button to advance one year To move faster keep pressing the button until the desired number appears With the correct year on the display press the Set button and then the month segment flashes ka Ora STEP 2 Set the Month Press and release the button until the correct month appears To move faster hold the M button down With the correct month on the display press the Set button and then the date segment flashes STEP 3 Set the Date Press and release the button until the correct day appears To move faster hold the M button down With the correct day on the display press the Set button and then the hour segment flashes STEP 4 Set the Hour Press and release the button to advance one hour To move faster hold the button down With the correct hour on the display press the Set button and then the minute segment flashes STEP 5 Set the Minutes Press and release the button to advance one minute To move faster hold the M button down With the correct minute on the display press the Set button and then the current unit of temperature starts flashing STEP 6 Select F or C Press and release the button to select the unit of temperature you want to use Press the Set button and the meter will E display
20. iod e g 14 14 tests in the last 7 days 37 ka Ore The 14 day average is calculated from the blood glucose results obtained during the last 14 days It also indicates how many blood glucose tests have been performed e g 28 28 tests in the last 14 days It is all the same for the 21 28 60 and 90 day average STEP 2 Recall Test Results After the 90 day average the most recent test result with date and time will be shown Press the M button once and the next most recent test result will appear Each time you press and release the M button the meter will recall up to your last 450 test results in order When the memory is full the oldest result is dropped as the newest is added 38 When reaching the last set of result End and M will be shown on LCD display and F d the meter will be turned off automatically n STEP 3 Exit the Memory Mode Keep pressing the M button for 5 seconds to turn off the meter a Oracle PLEASE NOTE The control solution results are NOT stored in the memory please also go to page 40 WARNING for information The list of past results and the result average are for blood glucose results only When pressing the button to recall the test results the meter will displayed date time and the unit of measurement first If you do not press the M button within 5 seconds the blinking
21. n the software to transmit data Results transmitted will include date and time Remove the cable and the meter will automatically turn off PLEASE NOTE While the meter is connected to the PC it is unable to perform a blood glucose test 42 CARING FOR YOUR METER AND TEST STRIPS To avoid the meter and test strips getting dirt dust or other contaminants please wash and dry your hands thoroughly before use Cleaning Your meter does not require special maintenance As no blood or control solution comes in contact with the meter there is no special cleaning required To clean the meter exterior wipe with a cloth moistened with tap water or a mild cleaning agent then dry the device with a soft and dry cloth Do not flush with water 2 Do not use organic solvents to clean the meter Storage I Meter Storage e Storage condition 20 C 60 C below 95 relative humidity e Always store or transport the meter in its original storage case 43 amp Oracle e Avoid dropping and strong impact e Avoid direct sunlight and humidity e Storage condition 4 C 40 C below 85 relative humidity Do not refrigerate e Store your test strips in their original vial only Do not transfer to other container e Store test strip packages in a cool and dry place Keep away from direct sunlight and heat e After removing a test strip from the vial immediately replace the vial cap and close it
22. ns or Comments about your EZ Health Oracle Blood Glucose Meter We are here to help 9am 5pm EST Mon Fri Toll Free 1 866 829 7926 www oraclediabetes com or www tremblayharrison com Important Before using these products carefully read the owner s manual For in vitro diagnostic use only Store at room temperature below 86 F 30 C Keep out of direct sunlight and humidity EZ PLUS WARRANTY Your EZ Health Oracle Blood Glucose monitor comes with the exclusive EZ PLUS five year warranty We warrant to the first retail purchaser that your EZ Health Oracle Blood Glucose monitor will be free from defects in material and workmanship for five years from the date of purchase The owner is required to submit a warranty card to Tremblay Harrison Inc within sixty days of the original purchase To obtain warranty service for such defects return the Product freight and insurance prepaid together with satisfactory proof of date of purchase such as a sales receipt or warranty card and shipping costs to Tremblay Harrison Inc 1684 Dufferin Street Toronto ON M6H 3M I Customers in Canada are asked to call Tremblay Harrison Inc toll free at 1 866 829 7926 Customers may take the product to the retail location where the product was purchased Tremblay Harrison will repair or replace any Product found to be defective and return it to you Any replacement product may be new refurbished or a different model This warranty will not ap
23. ommend you do AST ONLY in the following intervals e In a pre meal or fasting state more than 2 hours since the last meal e Two hours or more after taking insulin e Two hours or more after exercise Fi Do NOT use AST if e You think your blood glucose is low e You are unable to notice symptoms of hypoglycemia e Your AST results do not match the way you feel e You are testing for hyperglycemia e Your routine glucose results are often fluctuating e You are or may be pregnant How to increase the accuracy Stimulating blood perfusion by rubbing the puncture site prior to blood extraction has a significant influence on the glucose value obtained Blood from the site without rubbing exhibits a measurably different glucose concentration than blood from the finger When the puncture site was rubbed prior to blood extraction the difference was significantly reduced NOTE We suggest that you rub the puncture site for about 20 seconds before taking your sample INTRODUCTION OF THE SYSTEM Intended Use The system is intended for use outside the body in vitro diagnostic use It should be used only for testing glucose sugar and only with fresh capillary whole blood samples taken from the finger and the alternative sites including the palm the forearm the upper arm the calf and the thigh The system is intended for home use and in clinical settings It should not be used for the diagnosis of diabetes or for the testing of newborn
24. ood with a clean cotton swab Gently squeeze the punctured area to obtain another drop of blood Be careful NOT to smear the blood sample Apply the blood to the test strip 3 Ore A 6 lt a Oracle STEP 4 Apply blood into the test strip When 6 is flashing on the screen apply your blood to the absorbent hole of the test strip until the confirmation window is fully covered with blood The meter then begins to count down automatically STEP 5 Obtain an Accurate Result in 6 Seconds The result of your blood glucose test is shown after the meter counts to 0 This reading is automatically stored in the meter PLEASE NOTE e Do not push your finger with blood on it against the test strip or try to apply a smeared sample on the test strip e If you do not apply a blood sample to the test strip within 3 minutes the meter will automatically turn off You must remove and reinsert the test strip to restart the test procedure e The blood should completely fill the confirmation window before the meter begins to count down If you find that the confirmation window is not filled with blood when the meter is counting NEVER try to add more blood to the test strip Discard the test strip and retest with a new one e If you have trouble filling the test strip please contact customer service for help 32 STEP 6 Remove the Lancet Always use caution when removing the lancet To remove the lancet pull the cap o
25. ply if the defect or malfunction results from subjecting the Product to any but the specified voltage modification alteration or repairs of the Product by persons not authorized by Tremblay Harrison Inc misuse abuse damage during transit or lack of reasonable care with respect to the Product or failure to follow the written instructions enclosed with the Product THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES IN NO EVENT SHALL TREMBLAY HARRISON BE LIABLE FOR ANY LOSS INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER RESULTING FROM BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY EVEN IF TREMBLAY HARRISON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH INCONVENIENCE DAMAGE OR LOSS Tremblay Harrison Inc reserves the right to change the terms and conditions of this guarantee without informing the original purchaser The warranty is not transferable Manufactured by Tremblay Harrison Inc 1684 Dufferin Street Toronto ON M6H 3M1 Toll free 1 866 829 7926 www tremblayharrison com 52 v lt ea 2 Referent In vitro diagnostic medical device Do not reuse Consult instructions for use Keep away from sunlight Keep dry wey Temperature limitation Use by Date of manufacture Batch code Serial number N T O 2f Caution consult accompanying documents Biological risks 53
26. rol solu Shake the control solution vigorously and repeat tion vial very well the test again Expired or contaminated control Check the expiry date or the discard date of the solution control solution Control solution that is too warm Solution meter and test strips should come to or too cold room temperature 20 25 C 68 77 F before testing Repeat the test with a new test strip Meter malfunction Contact your local Customer Care Line at 866 829 7926 for help 50 SPECIFICATIONS Model No GMH B 1 GMH B2 Dimension amp Weight 96mm L x 20mm W x 46mm H 69 87 g Power Source two 5V AAA alkaline batteries Display LCD Memory 450 measurement results with date and time averaging Auto electrode inserting detection Auto sample loading detection Auto reaction time count down Sleeping Mode Power consumption less than 80uA Auto turn off after 3 minutes without action Temperature Warning Operating Condition 0 C 40 C below 85 R H noncondensing Storage Transportation Condition 4 C 40 C below 85 R H Measurement Unit mmol L Measurement Range 33 3mmol L Talking Function in both English and French The device has been certified to meet the electrical and safety requirements of IEC 60601 1 EN 60601 1 IEC 61010 1 EN 61010 1 EN 61010 2 101 EN 60601 1 2 EN 61326 5J 5 Ol we ay le Sri het OFACIE Warranty Registration Information Customer Care Call us with your Questio
27. rsons 2 Use the device only for the intended use described in this manual 3 Do not use strips and control solutions which are not supplied by the manufacturer 4 Do not use the device if it is not working properly or if it has suffered any damage 5 Before using any product to test your blood glucose read all instructions thoroughly and practice the test Do all quality control checks as directed and consult with a diabetes healthcare professional KEEP THESE INSTRUCTIONS 5O E J 4 fe orache TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT INFORMATION ABOUT ATERNATIVE SITE TESTING AST INTRODUCTION OF THE SYSTEM Intended Use Principle of Measurement Contents of the System Appearance and Key Function of the Meter Meter Display Segments Speaking Function Appearance of the Test Strip PREPARATION BEFORE USE Battery Replacement Setting the Meter and Deleting the Memory BEFORE TESTING Checking with EZ Health Oracle Control Solutions Important Control Solution Information Performing a Control Solution Test TESTING YOUR BLOOD Testing Procedure Expected Test Results COMPARING METER AND LABORATORY RESULTS USING THE METER MEMORY Viewing Results on the Meter Viewing Results on a Personal Computer 03 06 07 09 09 09 10 lI 12 13 14 15 16 17 22 22 23 24 27 28 34 35 37 37 4l CARING FOR YOUR METER AND TEST STRIPS 43 Cleaning 43 Storage 43 PROBLEM SOLVING GUIDE 46 Re
28. s Principle of Measurement The test is based on the measurement of electrical current generated by the reaction of glucose with the reagent of the strip The meter measures the current and displays the corresponding blood glucose level The strength of the current produced by the reaction depends on the amount of glucose in the blood sample lt Sy Ka OFe Contents of the System The system should be used with three main products the blood glucose meter test strips and a control solution These products have been designed tested and proven to work together as a system to produce accurate blood glucose test results Use only the EZ Health Oracle test strips and EZ Health Oracle or Autocode control solution with your EZ Health Oracle meter Your system includes Ameter 2 Your first time using guide 3 Test strips sold separately 4 Lancing Device with clear cap 5 10 Sterile lancets 6 Control solution Optional 7 Owner s manual 8 Sporty carrying case 9 Warranty card 10 CD with Audio Guide and Software PLEASE NOTE e Check your system to be sure that it is unopened prior to use and that it contains all parts listed above If either of these conditions occurred please return your system to the place of purchase e Please note that strips and control solutions are optional Those are not included in the standard kit Please ask your local agent or call toll free 1 866 829
29. sult Indicator 47 Error Message 48 Problem in Operation 49 SPECIFICATIONS 5 WARRANTY CUSTOMER CARE 52 f A wy E amp Y Oracle IMPORTANT INFORMATION e Severe dehydration and excessive water loss may cause false low results If you believe you are suffering from severe dehydration consult a healthcare professional immediately e Test results below 3 3 mmol L mean low blood glucose hypoglycemia Test results greater than 13 3 mmol L mean high blood glucose hyperglycemia If you get results below 3 3 mmol L or above 13 3 mmol L and do not have symptoms first repeat the test If you have symptoms or continue to get results that fall below 3 3 mmol L or above 13 3 mmol L follow the treatment advice of your healthcare professional e Apply only capillary whole blood sample to the absorbent hole Applying other substances to the absorbent hole will cause inaccurate results e If you are experiencing symptoms that are not consistent with your blood glucose test results and you have followed all instructions described in this owner s manual call your healthcare professional e Inaccurate results may occur in severely hypotensive individuals or patients in shock Inaccurate low results may occur for individuals experiencing a hyperglycemic hyperosmolar state with or without ketosis Critically ill patients should not be tested with blood glucose meters e Please refer to the test strip package insert for additional important
30. t a Oracle STEP 4 Apply Control Solution Move your finger with control solution on it to meet the absorbent hole of the test strip and the drop will be automatically drawn into the test strip Remove your finger until the confirmation window is filled The meter begins to count down To avoid contaminating the control solution with the content of the test strip you have to place a drop of control solution on a clean surface or on your finger tip first Then touch the test strip to the drop STEP 5 Read and Compare the Result After counting to 0 the test result of control solution is shown on the screen Compare this result with the range printed on the test strip vial It should fall within this range Out of range results If test results fall outside the range printed on the test strip vial check the section of Problem in Operation in troubleshooting guide and repeat the test If you continue to get out of range results it means that the system may not be working properly Do NOT test your blood Contact your local Customer Care Line at I 866 829 7926 for help 26 TESTING YOUR BLOOD Be sure to read this section and the test strip package insert found in the test strip box carefully before testing Make sure you have all items needed to test Blood Glucose Meter 2 Test Strip 3 Lancing Device 4 Sterile Lancet To reduce the chance of infection e Nev
31. your test result MESSAGE WHAT IT MEANS appears when your result is at reference range from 4 0 to 7 0 mmol L low appears when your result is from 1 1 to 3 9 mmol L It indicates that the result is below reference range LO appears when your result is below measurement limit which is less than 1 1 mmol L Lo or low symbol indicates hypoglycemia low blood glucose You should immediately treat hypoglycemia as recommended by your healthcare professional high appears when your result is greater than 10 0 mmol L It indicates that the result is higher than reference range KETONE appears together with high when your result is equal or higher than 13 3 mmol L This indicates there is a possibility of ketone accumulation if you are Type diabetes Please seek immediate medical assistance H appears when your result is above measurement limit which is higher than 33 3 mmol L ka Oracle Error Message MESSAGE WHAT IT MEANS ACTION Appears when the batteries can not provide enough power for a test Appears when inserting a used test strip Appears when ambient temperature is below system operation range Appears when ambient temperature is above system operation range Remove the strip after applying blood to the absorbent hole Problem with the meter 48 Replace the batteries immediately Test with a new test strip System operation range is 0 40 C 5