Home

Solar Charging Kit - Samlex America Inc.

image

Contents

1. e The resistances of the interconnecting cables will be balanced Allthe individual batteries battery strings will see the same series resistance e All the individual batteries will charge at the same charging current and thus will be charged to the same state at the same time e None of the batteries will see an overcharge condition If the Positive output cable of the Solar Charge Controller Cable A is connected to the Positive battery post of the first battery Battery 1 in Fig 9 2 or to the Positive battery post of the first battery string Battery 1 of String 1 in Fig 9 3 and the Negative output cable of the battery charger Cable B is connected to the Negative battery post of the first battery Battery 1 as in Fig 9 2 or to the Negative Post of the first battery string Battery 1 of Battery String 1 as in Fig 9 3 the following abnormal conditions will result e The resistances of the connecting cables will not be balanced The individual batteries will see different series resistances e All the individual batteries will be charged at different charging current and thus will reach fully charged state at different times The battery with lower series resistance will take shorter time to charge as compared to the battery which sees higher series resistance and hence will experience over charging and its life will be reduced 18 Please carry out the following routine maintenance e Inspect the solar p
2. 0 Punch or Awl 1 Silicone or any suitable roof sealant Contact your local RV Philips drive screw driver dealer or RV store for a recommendation on a sealant to suit 7 16 wrench your specific RV roof material 3 8 wrench 2 Anti galling lubricant to prevent thread galling of all Wire Stripper stainless steel fasteners exposed to outdoor environment This should be available at most hardware or auto parts stores If Wire Crimping Too anti galling lubricant is not available any standard lubricant Hand Drill will minimize the occurrence of thread galling Ya drill bit 3 If wiring distances are longer than 20 ft length of wire Jig saw or suitable cutting tool provided with the kit extra stranded copper wire will be Pliers required Wires should be 12 AWG or thicker single conductor Type UF Underground Feeder marked as sunlight resistant Type SE Service Entrance or Type USE USE 2 Underground Service Entrance Alternatively the following may be ordered for additonal 20 ft extension e Solar Panel Connecting Wlres Kit SCW 20 2 Solar Panel Multi Contact Connectors MC4 2 Each of the Samlex Solar Charging Kits come with a 30 Amp PWM Charge Controller Model No SCC 30AB to optimally charge your batteries from the solar panel The Solar Charge Controller comes with its own detailed manual Read the manual in detail The instructions in this Section are only a brief summary of information contai
3. 2 Le fil N gatif du panneau solaire est termin par un connecteur MC4 m le d sign par la raccorder au connecteur MC4 Femelle d sign par qui est attach au fil d extension N gatif Assurer vous que les languettes crans sont verrouill es pour une connexion solide L extr mit d nud e du fil d extension N gatif assume d sormais une polarit n gative 3 Connecter les deux fils vers le circuit ext rieur photovolta que Mise en Garde Assurer vous que la polarit 4 ou des fils soit identifi e correctement avant de les branch s un circuit ou un dispositif Les dommages d l inversion de polarit ne sont pas couverts par la garantie Connexion de Deux Panneaux Solaires Adjacents en Parall le Fig 3 4 oe cs a a es ee oe ar ge a er ee a o ar gt e e oo a Trousse SBC 2 f Connecteur MC4 I I femelle Trousse SCW 20 2 HB 1 ta SE RB E a b Au Contr leur a 1 7 de Charge 2 C l Connecteur MC4 I 2 L m le I La Fig 3 4 connexion de deux panneaux solaires adjacents en parall le Deux ou plusieurs panneaux solaires peuvent tre connect s en parall le pour augmenter le courant de sortie la m me tension de sortie La Fig 6 5 ci dessus illustre l arrangement pour le raccordement de deux panneaux solaires en parall le l aide des fil de connexion SCW 20 2
4. A Division of Samlex America Inc Rr Owner s pesse read 1 r IS Ma a Charging Kit Manual before SRV 100 30A Je it SRV 150 30A uude OWNER S MANUAL 10 11 General Safety Description amp Components Connector System for Connecting Solar Panels Installation Overview Tools amp Materials Required for Installation Charge Controller Installation Solar Panel Installation Wiring Typical Battery Connections Routine Maintenance Warranty Warnings Please read the Owner s Manual carefully before attempting to carry out z a any installation and wiring Contact your RV dealer or Technical support at Samlex America 1 800 561 5885 for any questions concerning the installation Installation and Wiring Compliance Installation and wiring must comply with the local and National Electrical Codes and must be done by a certified electrician 1 2 Disconnect all power sources before carrying out the installation Make sure correct polarity is observed when making connections between the solar panel Charge Controller and the battery Damage due to reverse polarity connection is not covered by warranty Make sure all wire connections are secure as loose connections may cause sparks Wear appropriate clothing and safety gear including protective eyewear when performing any electrical installation Preventing Fire and Explosion Hazards Working with electronic electrical equipment may produce arcs or spark
5. d fectueuse doit tre retourn e aux frais de l acheteur l endroit autoris Une d claration crite d crivant la nature du d faut la date d achat le lieu d achat et le nom de l acheteur son adresse et son num ro de t l phone doivent galement tre inclus Si apr s examen du Garant le d faut se r v le tre le r sultat de fabrication ou de mat riel d fectueux le mat riel sera r par ou remplac au choix du garant sans frais et retourn l acheteur aux frais du garant Aucun remboursement du prix d achat sera accord l Acheteur moins que le Garant ne soit pas en mesure de rem dier au d faut apr s avoir b n fici d un nombre raisonnable d occasions pour ce faire Le service de garantie sera effectu uniquement par le Garant Toute tentative visant rem dier au d faut par une personne autre que le Garant annulera cette garantie Il n y aura pas de garantie pour les d fauts ou dommages caus s par une mauvaise installation ou un mauvais raccordement un abus ou un mauvais usage de l quipement y compris l exposition une chaleur excessive la pulv risation d eau douce ou de mer ou l immersion dans l eau Aucune autre garantie expresse n est accord e et il n existe aucune garantie qui s tend au del de celle d crite ici Cette garantie remplace express ment toute autre garantie expresse ou implicite y compris toute garantie implicite de qualit marchande d ad quation l application
6. 7 3 Le serrage d un boulon ou d une vis m canique conventionnel engage l crou encastr provoquant ainsi l expansion de la douille Cette m thode assure la fixation aux toits mince du VR en bombant vers le haut et contre la surface inf rieure du toit Fig 7 6 Si elle est utilis e dans un trou borgne dans un mat riau de surface solide le caoutchouc s largira vers l ext rieur pour assurer une fixation solide La Fig 78 7 Le n opr ne et le laiton r sistent la plupart des conditions m t orologiques En outre l crou douille rend le trou perc parfaitement tanche contre les fuites d air et de liquide Module Solaire 1 4 20x3 4 Boulon Bride 1 4 Rondelle Plate Support Montage Toit du VR 1 4 Contre crou S La Fig 7 1 Fixation des panneaux solaires au support de montage 5 trous Bride c 1 2 Diametre 1 4 crou encastr en laiton La Fig 7 3 Construction d un crou douille Installation typique d un crou douille La Fig 7 6 Quand le boulon est serr le corps en n o pr ne de l crou douille est comprim et dilat la fois le forcant se loger bien dans les filets du boulon et contre la surface interne du mat riau de toit mince du VR La Fig 7 5 Le support de montage 5 trous est plac e contre la bride de l crou douille et est fix par le b
7. Connecteurs MCA Les Figs 3 1 et 3 2 Les connecteurs MCA mentionn s dans ce guide ont t d sign s m le et femelle selon les caract ristiques des encarts d accouplement dans les bornes Dans le connecteur MCA m le 1 de la Fig 6 2 l encart d accouplement interne 2 Fig 6 2 est une broche m le La broche est dispos de deux fentes 3 de la Fig 6 2 pour l insertion dans les deux languettes de verrouillage enfichables 6 de la Fig 6 2 dans le connecteur MCA femelle 4 de la Fig 6 2 pour un raccordement solide Ce connecteur est d sign par Dans le connecteur MCA femelle 4 de la Fig 6 2 l encart d accouplement interne 5 de la Fig 6 2 est une prise femelle cylindrique Elle est dot e de deux languettes de verrouillage enfichables 6 de la Fig 6 2 qui sont ins r es dans les deux fentes 3 de la Fig 6 2 du connecteur MC4 m le 1 de la Fig 6 2 pour un raccordement solide Un fil est serti sur les encarts d accouplement 2 et 5 de la Fig 6 2 en utilisant un outil sertissage sp cial concu pour les connecteurs MCA Apr s avoir serti le fil le filet rapport doit tre assis en toute s curit l int rieur du boitier et le d tendeur sceau de tension 7 de la Fig 6 2 doit tre serr fond pour assurer une tanch it l eau compl te LEGENDE La Fig 3 1 Connecteur MC4 M le marqu La Fig 3 1 1 l encart d accouplement m le 2 2 Fentes qui acceptent les langu
8. La Fig 9 2 Connexion en Parall le Lorsque deux ou plusieurs batteries sont branch es en parall le leur tension reste la m me mais leurs capacit s AH s accumulent La fig 10 2 ci dessus illustre 4 batteries de 12V 100 AH branch es en parall le pour former une banque de batteries de 12V avec une capacit de 400 Ah Les quatre bornes Positives des Batteries 1 4 sont en parall le reli es entre elles et ce lien Positif commun devient la borne Positive du groupe de batteries de 12V De la m me fa on les quatre bornes N gatives des Batteries 1 4 sont en parall le reli es entre elles et ce lien N gatif commun devient la borne N gative du groupe de batteries de 12V 17 Connexion des Batteries en S rie Parall le Cha ne 1 Cha ne 2 P O S Batterie 1 Batterie 2 Batterie 3 Batterie 4 Cable A Batterie de 6V Batterie de 6V Batterie de 6V Batterie R gulateur de charge solaire SCC 30AB vue arri re Cable B La Fig 9 3 Connexion en S rie Parall le La Fig 9 3 ci dessus montre un branchement en s rie parall le compos de quatre batteries de 6V 200 Ah pour former une banque de batteries de 12V 400 Ah Deux batteries de 6V 200 Ah les Batteries 1 et 2 sont branch es en s rie pour former une batterie de 12V 200 Ah Cha ne 1 De la m me fa on deux batteries de 6V 200 AH les Batteries 3 et 4 sont branch es en s rie pour former une banque d
9. snap in type of locking tabs 5 1 of the mating MC4 Female Connector Fig 3 2 3 DA 3 Strain Relief amp Seal 2 LEGEND Fig 3 2 MC4 Female connector marked Fig 3 2 3 Strain Relief amp Seal 5 4 4 Female Contact Insert 3 5 Snap in type of locking tabs that slide inside locking slots 2 of the mating MC4 Female Connector Fig 3 1 3 Output Wires and Connections on the Solar Panel Fig 3 3 shows the output wires and connections on the solar panel The output wires from the junction box of the solar panel are terminated with the help of MC4 connectors The Positive wire is terminated with a MC4 Female Connector marked and the Negative wire is terminated with a MC4 Male Connector marked Warning When the surface of the solar panel array is exposed to sunlight a DC voltage appears at the output terminals turning it into a live voltage source For example a 24 V nominal solar panel my put out an open circuit voltage of around 45 VDC that may produce electrical shock Multiple solar panels connected in series to increase the output voltage will put out higher lethal voltages To avoid any electrical shock hazard during installation make sure that the solar panel array is covered with an opaque dark material to block solar irradiation Extending to the Output Wires of the Solar Panel Fig 3 3 Caution Note that the Positive extension wire has a
10. Survol de l Installation Outils et Mat riaux Requis Pour l Installation Installation du R gulateur de Charge Installation du Panneau Solaire C blage Branchement Typiques de Batterie Entretien P riodique Garantie Mise en Garde Veuillez lire attentivement le guide de l utilisateur avant d effectuer toute z EN installation et tout c blage Contactez votre marchand de VR ou le soutien technique de Samlex America 1 800 561 5885 pour toute question concernant l installation Conformit de l installation et du C blage L installation et le c blage doivent tre conforme aux codes lectriques locaux et nationaux et doivent tre faits par un e lectricien ne certifi e 1 D branchez toutes les sources de puissance avant de proc der l installation Assurez vous que la bonne polarit est observ e lorsque vous branchez le panneau solaire le r gulateur de charge et la batterie Les dommages dus un inversement de la polarit ne sont pas couverts par la garantie 3 Assurez vous que toutes les connexions soient bien serr es puisque les connexions l ches peuvent provoquer des tincelles 4 Porter des v tements et du mat riel de s curit appropri s y compris des lunettes de protection lors de toute installation lectrique Pr vention des risques d incendie et d explosion L utilisation de l quipment lectrique lectronique pourrait produire des arcs lectriques ou tincelles Par cons quent il n
11. batterie se trouvera en tat de surcharge Si le c ble de sortie Positif du chargeur de batterie C ble A est reli la borne Positive de la premi re batterie Batterie 1 dans la Fig 10 2 ou la borne positive de la premi re chaine de batteries Batterie 1 de la Cha ne 1 dans la Fig 10 3 et le c ble de sortie N gatif du chargeur de batterie C ble A est reli la borne positive de la premi re batterie Batterie 1 dans la Fig 9 2 ou la borne N gative de la premi re cha ne de batteries Batterie 1 de la Cha ne de batteries 1 comme dans la Fig 9 3 les conditions anormales suivantes en r sulteront Lesr sistances des c bles de connexion ne seront pas quilibr es Les batteries individuelles auront des r sistances en s rie diff rentes Toutes les batteries individuelles seront recharg es des diff rents courants de charge et donc atteindront un tat compl tement charg des moments diff rents e La batterie avec une plus faible r sistance en s rie n cessitera moins de temps pour tre charg e par rapport la batterie qui voit une plus grande r sistance en s rie et donc subira des surcharges et sa dur e de vie sera r duite 18 Veuillez vous assurer d entretenir le syst me solaire dans la mani re suivante e Inspectez les panneaux solaires et assurez vous que la surface soit exempte de poussi re de salet et d autres d bris nettoyer avec un chiffon humide ou un nettoyant pou
12. be of Negative polarity 3 Connect the two PV Extension Wires to the Charge Controller Warning 1 Ensure that the polarity or of the wires is identified correctly before connecting to the Charge Controller Damage due to wrong polarity may not be covered under warranty Connecting Second Adjacent Solar Panel in Parallel Fig 3 4 as as a es US as Se ee a ar gt gt a CS O ee oe a ar qe gt a o a is E SBC 2 Kit Oy MC4 Female Branch Connector SCW 20 2 Kit 0 0 0 000 0000 I I I uoo I I I pos ws Im To Charge 1 Controller EDS In PO LES I MC4 Male Mo ee ete Branch Connector Fig 3 4 Connecting two adjacent solar panels in parallel A second solar panel can be connected in parallel with the panel provided in the kit to increase the current output at the same output voltage Fig 3 4 above shows the arrangement for connecting the second solar panel in parallel using the Solar Panel Connecting Wire Kit Model SCW 20 2 supplied with this kit and MC4 Branch Connector Kit SBC 2 sold separately This arrangement is applicable if the two solar panels are to be connected in parallel and are mounted adjacent to each other The output wires of the two solar panels are first connected in parallel using the MC4 Male and Female Branch Connectors The outputs of the Branch Connectors are then connected t
13. d un mat riau opaque noir qui bloquerait le rayonnement solaire Extension aux Fils de Sortie du Panneau Solaire Fig 3 3 Mise en Garde 1 Notez que le fil d extension Positif est muni d un connecteur d accouplement MC4 m le d sign par qui s accouple avec le connecteur correspondant MC4 Femelle d sign par sur le fil Positif du panneau 2 De m me le fil d extension N gatif comporte un connecteur d accouplement MCA femelle d sign par qui s accouple avec le connecteur correspondant MC4 M le d sign par sur le fil N gatif du panneau m 2 Connecteur MC4 Femelle ca S d sign par 4 pour le fil Connecteur MC4 Male photovoltaique N gatif d sign par Au Contr leur de Charge TUE pes Den re m Positif Connecteur MCA Femelle d sign par La Fig 3 3 Connexion des c bles d extension au c bles de sortie du panneau solaire 1 Le fil Positif du panneau solaire est termin par un connecteur MC4 Femelle d sign par Le raccorder au connecteur MC4 M le d sign par qui est attach au fil d extension Positif Assurer vous que les languettes enfichables sont verrouill es pour une connexion solide L extr mit d nud e du fil d extension Positif assume d sormais une polarit positive Utilisez un morceau de ruban rouge ou de manchon rouge pr s de l extr mit d nud e pour identifier le fil Positif
14. de Po automobiles Si un lubrifiant anti grippage n est pas disponible Scie Auteuse ou autre outil de n importe quel lubrifiant standard minimisera le grippage du coupage adapt filetage Pinces 3 Si les distances de c blage sont plus longues que les longueursde fil fourni avec la trousse du fil en cuivre toronn sera n cessaire Les fils devraient tre de calibre 12 AWG ou plus gros conducteur unique de type UF Underground Feeder marqu r sistant la lumi re du soleil Type SE Entr e de Service ou de type USE USE 2 Entr e de Service Souterraine Si vous en avez besoin les kits suivants pourraient tre command pour un extension de 6 m Fils de Connexion pour panneau solaire SCW 20 2 Connecteurs Multi Contact MC4 2 La Trousse de Recharge Solaire Samlex est livr e avec un r gulateur de charge avec MLI de 30 A modele no SCC 30AB qui vous permet de recharger vos batteries de mani re optimale partir du panneau solaire Le r gulateur de charge solaire est livr avec son propre guide d utilisation d taill Lisez attentivement le manuel Les instructions contenues dans la rubrique pr sente ne sont qu un bref r sum des informations contenues dans le guide S assurer que les panneaux solaires et les batteries soient d connect s du r gulateur de charge avant l installation du r gulateur de charge Le r gulateur de charge devrait id alement tre situ dans une zone relativement pro
15. ordinaire pour laquelle ces biens sont utilis s ou d ad quation un usage particulier ou de toute autre obligation de la part du Garant ou de ses employ s et repr sentants REJET DE RESPONSABILITE Il n y aura aucune responsabilit que ce soit de la part du Garant ou de ses employ s et repr sentants pour des blessures des personnes ou des dommages une personne ou des personnes ou des dommages la propri t ou la perte de revenus ou de profits ou de toute cons quence ou dommage r sultant qui peuvent tre d clar s avoir t engag s par l utilisation ou la vente de l quipement y compris tout chec ventuel ou dysfonctionnement de l quipement ou d une partie de celui ci Le garant n assume aucune responsabilit pour les dommages directs ou indirects de toute nature Samlex America Inc le Garant 103 4268 Lozells Avenue Burnaby BC V5A 0C6 Canada 604 525 3836 20 NOTES NOTES NOTES Information Contact Num ros Sans Frais T l 1800 561 5885 T l c 1 888 814 5210 Num ros locaux T l 604 525 3836 T l c 604 525 5221 Site internet www samlexamerica com Entrep t USA Kent WA Entrep t Canada Delta BC Adresse email pour passer commande orde
16. to Charge Controller Srl 3 Inside Charge Controller SCC 30AB Box Tapping Screw 7x19 x 5 8 Flat Head Philips For mounting of Charge Controller Srl 3 Inside Charge Controller SCC 30AB box Owner s Manual for the Kit Owner s Manual for Charge Controller SCC 30AB Inside Charge Controller box 100W Kit SRV 100 30A 1 0 1 N ooo 150W Kit SRV 150 30A 0 1 1 D nn The Positive and Negative outputs of the solar panel are fed through a water tight Junction Box Appropriate size of wires are connected to the Junction Box for further connections The solar panels supplied with these kits are provided with approximately 3 ft each of Positive amp Negative wires that are pre connected to the Junction Box The free ends of the wires are terminated with special mating type of connectors for ease of extending these wires for further connections The special mating type of connectors used for the 3 ft wires provided with the solar panels and also for the separate extension wires are as follows SolarLine MC4 Series manufactured by Multi Contact or compatible General Information on MC4 Connector System MC4 Connector System consists of male and female connectors This type of connector system is easy to install and uses snap in type of safety locking clips to lock the two mating connectors thereby avoiding unintentional disconnection Also the mating contacts are sealed against ingress of dust and water Specificat
17. will minimize the occurrence of thread galling Fix the mounting brackets Fig 7 2 to the frame of the previously positioned solar panel using the slotted opening and the 4 20 x 34 Flange Bolt Nylon Locknut and flat washer Fig 7 1 Using a 7 16 wrench tighten the nuts to secure the mounting brackets to the PV panel Recommended tightening torque is 15 lbs Position the panel with the attached mounting brackets at the desired location on the RV roof and mark the position of the desired mounting hole using a suitable marker by tracing the hole on the mounting bracket Please ensure that the mounting surface on the RV roof is strong enough to support the mounting hardware solar panel and wind loads The centre and end holes on the mounting brackets Fig 7 2 are sized to accept the Y hardware supplied with the unit If the use of larger sized hardware is desired 3 8 holes can be used Well Nut for anchoring Solar Panel to RV Roof 12 6 A Well Nut is a bushing of tough Neoprene rubber with a flange at the top end and a captive brass nut mounted within the bore at the bottom end Fig 7 3 Tightening a conventional machine bolt or screw engages the captive nut thereby causing the bushing to expand outwards This fastens securely to thinner RV roofs by bulging up and against the bottom surface of the roof Fig 7 6 If used in a blind hole in a solid surface material the rubber will expand outw
18. with 4 AWG 12 pigtails Splice one pigtail to the Positive wire end and use the other pigtail for battery connection N Warning Be careful not to short the battery ATC 10 10A Fuse Solar Panel Fuse Holder E Fig 8 2 Fig 8 3 4 Pigtails AWG 12 Inline Fuse Ring Fork See Fig 8 4 terminal terminal for Fig 8 4 for battery Controller Inline ATC Fuse Holder and ATC 10 Fig 8 1 Wiring Layout end end 10a Fuse Not Supplied Battery Use inline 10A ATC Type Fuse with ATC Fuse Holder Fig 8 4 as close to the battery as possible 14 Wiring From Solar Panel to Charge Controller 1 Determine the position of the solar panel on the RV roof While positioning panels avoid shading of the solar panel by neighbouring obstacles such as vents air conditioners TV antennas etc As far as possible position the panels to minimize wiring distance between the solar panel and the Charge Controller Place the panel at least 8 10 inches away from the RV roof edges and leave sufficient space to walk around the panel and access the mounting hardware 2 Make sure the thickness of the roof at the installation location is at least V thick and the material is strong enough to provide mechanical support to the solar panel and mounting hardware against possible wind loading Place the panel length wise to reduce the effects of wind loading on the RV 1 Negative wire with MC4 Female connector marked
19. 0 8 8 8 Contre crou Ya po Hex Acier Inox encart en nylon pour le boulon bride Srl 6 4 4 9 crou douille Taile d crou 1 4 20 Longueur 1 po tige de diam tre d un po pour 4 4 la fixation du support de montage SRI 5 au toit du VR ou autre surface 10 Boulon Bridet 1 4 20 x 1 po Hex Acier INOX Pour la fixation du support de 4 4 montage Srl 5 l crou douille Srl 9 11 Serre C ble pour les C bles d Extension PV Srls 4 1 amp 4 2 6 6 12 Vis taraudeuse 8 pointe cruiciforme pour le serre c ble Srl 11 6 6 13 Collier de C ble pour les C bles D extension Sri 4 1 et 4 2 6 6 14 Cosse circulaire isol e taille de goujon de 5 16 po pour tailles de c ble de AWG 10 2 2 3112 Pour cr per le c ble entre la batterie et le contr lleur 15 Cosses fourche isol es pour taille de c ble de AWG 10 12 4 4 2 pcs pour cr per aux bouts d nud s des c bles d extension PV Srl 4 1 and 4 2 pour la connexion au contr lleur de charge Srl 3 2 pcs pour cr per aux bouts d nud s des c bles de batterie Srl 4 1 and 4 2 pour la connexion au Contr leur de charge Srl 3 Dans la Bo te SCC 30AB 16 Vis taraudeuses 7x19 x 5 8 po t te plate pointe cruciforme Pour le montage du 4 4 contr lleur de charge Srl 3 Dans la bo te SCC 30AB 17 Guide d utilisation pour la trousse 1 1 18 Guide D Utilisation du Contr leur de Charge Dans sa bo te 1 1 Les sorties Positives et N gativ
20. Applications Syst mes Sur Toit R sidentiel e Syst mes Sur Toit de B timent Commerciell Industriel e Applications aux Endroits Rurals Autres Applications Li es Au R seau ou Hors R seau e Applications Automobiles Marines et pour VR La Table 2 1 Sp cifications des Panneaux Solaires Param tre Puissance Nominale Maximale STC Pmax Tension de Puissance Maximale Vpm Courant de Puissance Maximale lpm Tension en Circuit Ouvert Vco Courant de Court Circuit Ics Rendement du Module Classification des Cellules No de Cellules Tension Maximale du Syst me Classification du Fusible en S ries Boite Jonction Temp rature de Fonctionnement Dimensions Poids STC Coefficient de Temp rature du Courant Isc Panneau de 150W avec la Trousse de Panneau de 100W avec la Trousse de Rechargement Solaire SRV 150 30A Rechargement Solaire SRV 100 30A 150 W x 396 100W 3 18 38V 19 29V 8 16A 5 18A 22 68V 22 93V 8 82A 5 81A 15 42 15 10 Polycryistallin Monocryistallin 36 36 UL 1703 600VDC IEC 61215 16730 1000VDC 15A 10A IP 65 avec 3 Diodes de Blocage Cable de 4mm avec Connecteurs MC4 Compatibles 40 C to 85 C 40 F to 185 F 660 x 1474 x 35 2mm 26 x 58 03 x 1 39 po 552 x 1200 x 35 2mm 21 73 x 47 25 x 1 39 po 12 Kg 26 4 livres 8 Kg 17 63 livres clairement nergetique de Rayonnement Solaire 1000 W M2 Spectre AM 1 5 Temp rature Cellulaire 25 C 77 F 0 08 C 0 04 C La
21. Table 2 1 Sp cifications des Panneaux Solaires Parametre Panneau de 150W avec la Trousse de Panneau de 100W avec la Trousse de Rechargement Solaire SRV 150 30A Rechargement Solaire SRV 100 30A Coefficient de Temp rature de la 0 34 C 0 33 C Tension Voc Coefficient de Temp rature de la 0 43 C 0 37 C Puissance Pmax D tails du Contr leur de Charge SCC 30AB Veuillez vous r f rer au Guide d Utilisation qui a t livr avec le Contr leur de Charge Les d tails des composants compris dans la Trousse sont crits si dessous La Table 2 2 Liste des Composants La Trousse La Trousse SRV 100 30A SRV 150 30A No S rial Description de 100W de 150W 1 Panneau Solaire de 100W 1 0 2 Panneau Solaire de 150W 0 1 3 Contr leur de Charge MLI de 30 Amp Mod le SCC 30AB 1 1 4 Le Kit des C bles de Connexion de Panneaux Solaires Mod le SCW 20 2 compos de 4 1 C ble d Extension PV Positive 1 1 de 6m en longueur AWG 12 Connecteur M le MC 4 d un bout et d nud l autre 4 2 C ble d Extension PV Negative 1 1 de 6m en longueur AWG 12 Connecteur Femelle MC 4 d un bout et d nud l autre 6m en longueur 5 Support de Montage 5 Trous pour la fixation du Panneau tau Toit du VR ou 4 4 autre surface 6 Boulon Bride 1 4 20 x 34 po Hex Acier INOX pour la fixation du pannaeeau au 4 4 support de Montage Srl 5 7 Rondelle Plate 1 4 INOX Sous le boulon Bride Srls 6 et 1
22. V 2 Positive wire with MC4 Male connector marked Fig 8 5 Solar Panel Connecting Wires kit SCW 20 2 3 Solar Panel Connecting Wires kit SCW 20 2 consisting of 2 pre assembled 20 ft AWG 12 Positive Negative PV extension wires have been provided see Fig 8 5 The wires have MC4 mating connectors on one end for connecting to the solar panel amp bare ends on the other side for connecting to the Charge Controller The wires are marked 4 amp and for identification of the polarity 4 Please read Section 3 on connecting PV Extension Wires to the panels yi Refrigerator Vent Cover Vent A Screen R Fig 8 6 PV Wire Entry Through RV Vent 15 5 The wire pair from the solar panel can be routed to the interior of the RV through the roof top refrigerator vent Find where the refrigerator vent is located on the roof of the RV See Fig 8 6 6 Select a suitable mounting location for the solar panel preferably as close to the vent as possible The mounting surface should be strong enough to support the mounting hardware the solar panel and wind loads 7 Take off the vent cover to gain access to the duct opening and keep the vent fastening hardware safely as the vent cover will have to be replaced after the wires have been routed 8 The wires from the solar panel can be routed by either of the two following methods A Hole in the side of the vent Drill a suitable hole i
23. anels and make sure the surface is free from dust dirt and other debris Clean with a wet cloth or glass cleaner if necessary e Check to make sure all structural components mechanical fasteners and electrical connections are secure clean and corrosion free Check and maintain battery electrolyte levels at regular intervals as per battery manufacturer s recommendations if flooded wet cell Lead Acid batteries are used Check and replace damaged components if necessary 19 Warranty The Samlex Solar Charging Kits SRV 100 30A amp SRV 150 30A manufactured by Samlex America Inc the Warrantor are warranted to be free from defects in workmanship and materials under normal use and service The warranty is in effect from the date of purchase by the user the Purchaser Warranty period for various kit components 100W 150W Solar Panel 5 year product workmanship warranty 12 year 90 power output warranty 25 year 80 power output warranty Samlex 30 Amp Solar Charge Controller 5 year product workmanship warranty Model SCC 30AB Mounting Hardware and Wiring 5 year product workmanship warranty Warranty outside of the United States and Canada is limited to 6 months For a warranty claim the Purchaser should contact the place of purchase to obtain a Return Authorization Number The defective part or unit should be returned at the Purchaser s expense to the authorized location A written statement describing the nature of the def
24. ards to create a secure fastening Fig 7 7 The Neoprene and brass resist most environmental conditions solar module 1 4 20x3 4 flange bolt 1 4 flat washer mounting bracket S RV roof 1 4 locknut ES Fig 7 1 Attaching solar panel to 5 hole mounting bracket flange 1 2 diameter 1 4 captive brass nut Le A Fig 7 3 Construction of a Well Nut Typical Installation of a Well Nut Fig 7 4 Well Nut is in serted into a pre drilled hole with its flange against the outer sur face There is no need for access to the inner side Fig 7 5 The 5 hole mounting bracket is placed against the flange of the Well Nut and is secured by the bolt engaging the cap tive brass nut Fig 7 6 As the bolt is tightened the neoprene body of the Well Nut is compressed and ex panded forcing it tightly into the bolt s threads and against the inner surface of the thin RV blind hole in a solid material the body of the Well Nut expands tightly against the walls of the hole effecting a secure dependable fastening roof material 7 To install the Well Nuts drill holes 14 deep at the marked positions using a Y size drill bit Make sure that drilling does not interfere with pre existing wiring installations 8 Apply silicone or any appropriate sealant recommended by your RV dealer generou
25. attery 95 6V Battery Fig 9 3 Series Parallel Connection Figure 9 3 above shows a series parallel connection consisting of four 6 V 200 Ah batteries to form a 12 V 400 Ah battery bank Two 6 V 200 Ah batteries Batteries 1 and 2 are connected in series to form a 12 V 200 Ah battery String 1 Similarly two 6 V 200 Ah batteries Batteries 3 and 4 are connected in series to form a 12 V 200 Ah battery String 2 These two 12 V 200 Ah Strings 1 and 2 are connected in parallel to form a 12 V 400 Ah bank A CAUTION When 2 or more batteries battery strings are connected in parallel and are then connected to the Solar Charge Controller SCC 30AB See Figs 9 2 and 9 3 given above attention should be paid to the manner in which the Solar Charge Controller is connected to the battery bank Please ensure that if the Positive output cable of the Solar Charge Controller Cable A is connected to the Positive battery post of the first battery Battery 1 in Fig 9 2 or to the Positive battery post of the first battery string Battery 1 of String 1 in Fig 9 3 then the Negative output cable of the Solar Charge Controller SCC 30AB Cable B should be connected to the Negative battery post of the last battery Battery 4 as in Fig 9 2 or to the Negative Post of the last battery string Battery 4 of Battery String 2 as in Fig 9 3 This connection ensures the following Cable A Solar Charge Controller SCC 30AB rear view Cable B
26. che de la batterie Le r gulateur de charge doit tre install l int rieur dans un endroit sec Le r gulateur de charge est concu pour tre encastr sur un mur ou un meuble de sorte que le c blage l arri re soit accessible Laisser un espacement ad quat de 2 3 pouces derri re l unit pour accueillir le r gulateur de charge et le c blage En utilisant le mod le de d coupe dans le guide du r gulateur de charge marquer la d coupe sur la surface de l installation et l emplacement des trous de fixation l aide d une perceuse main et d un foret appropri percer les trous de fixation l aide d une scie sauteuse ou d un outil de coupe appropri couper le mat riau partir de la surface de montage 10 Apr s avoir c bl les bornes du r gulateur de charge voir la Section 6 propos le c blage fixer la plaque de montage la surface d installation en utilisant les vis fournies avec le r gulateur de charge 7 x 19 5 8 po vis autotaraudeuse t te plate cruciforme 11 L acier inoxydable peut tre soumis un processus appel le grippage du filetage dans lequel les boulons peuvent tre d viss s et ou les filets des boulons s aggrippent au filet de l crou Appliquer un lubrifiant anti grippage toutes les attaches en acier inoxydable avant l installation disponible la plupart des quincailleries ou magasins de pi ces automobiles Si un lubrifiant anti grippage n est pas disponib
27. cteur MCA Male et un connecteur MCA Femelle qui sont vendus s par ment dans un kit optionnel Mod le MC4 2 Un ensemble des fil de connexion SCW 20 2 et le kitoptionnel des connecteurs MC 4 MC4 2 est d abord utilis pour la connexion entre les deux panneaux Le kit optionnel SBC 2 est utilis pour les mettre en paral lle Puis le deuxi me ensemble de fils de connexion SWC 20 2 est utilis pour la connexion au circuit ext rieur photovoltaique SURVOL DE L INSTALLATION a Mise en Garde 1 S CURIT Veuilles lire la Section 1 Consignes de S curit G n rales avant d effectuer l installation 2 PR CAUTIONS PRENDRE EN TRAVAILLANT AVEC LE R GULATEUR DE CHARGE MODELE SCC 30AB Si deux ou plusieurs panneaux solaires sont branch s en s rie parall le faites en sorte que la somme des valeurs nominales de courant de court circuit de toutes les chaines du panneau n exc de pas 80 du courant nominal du r gulateur de charge soit 24 A pour le r gulateur de charge de 30 A La tension en circuit ouvert du panneau solaire la tension maximale dans ne doit pas d passer 50 V Per Diagramme de l Installation La Fig 4 1 a sous e 10 Lire le guide en d tail et chercher comprendre la proc dure d installation Ouvrir l emballage et s assurer que toutes les pi ces ont t recues selon la liste des pi ces dans le guide Page 5 Disposer des outils n cessaires pour effectuer l installation Une
28. e batteries de 12V avec une capacit de 200 AH Cha ne 2 Ces deux batteries de 12V 200 AH soit les Cha nes 1 et 2 sont branch es en parall le pour former une banque de batteries de 12V 400 AH A Mise en Garde Lorsque 2 ou plusieurs batteries cha nes de batteries sont branch es en parall le et sont ensuite branch es au R gulateur de Charge Solaire SCC 30AB voir les Figs 9 2 et 9 3 ci dessus faites attention la fa on dont le r gulateur de charge solaire est branch la banque de batteries Faire en sorte que si le c ble de sortie positif du r gulateur de charge solaire C ble A est reli la borne Positive de la premi re batterie Batterie 1 sur la Fig 9 2 ou la borne Positive de la premi re cha ne de batteries Batterie 1 de la Cha ne 1 dans la Fig 9 3 puis le c ble de sortie N gatif du R gulateur de Charge Solaire SCC 30AB C ble B doit tre reli la borne N gative de la derni re batterie Batterie 2 comme dans la Fig 9 2 ou la borne N gative de la derni re cha ne de batteries Batterie 4 de la cha ne 2 comme dans la Fig 9 3 Ce branchement garantit le suivant e Les r sistances des c bles d interconnexion seront quilibr es e Toutes les batteries individuelles cha nes de batteries g n reront la m me r sistance en s rie Toutes les batteries individuelles vont se recharger avec le m me courant de charge et donc arriveront au m me tat au m me moment e Aucune
29. e doit pas tre utilis dans les endroits ou il y a des mat riaux ougaz n cessitant des quipements ignifuges par exemple des espaces contenant des machines alimenter par essence des r servoirs d essence ou des compartiments batterie Pr cautions prendre en travaillant avec des batteries Les batteries contiennent de l acide sulfurique lectrolyte corrosif Certains pr cautions doivent tre prises afin d emp cher tout contact avec la peau les yeux ou les v tements Les batteries produisent de l oxyg ne et de l hydrog ne m lange de gaz explosif lorsqu elles sont recharg es Ventilez fond la zone de la batterie et suivez les recommandations du fabricant pour l emploi de la batterie e Ne jamais fumer ni mettre une flamme proximit des batteries Soyez prudent r duisez toute risque de chute d objets m talliques sur la batterie ce qui pourrait provoquer des tincelles ou court circuiter la batterie et les autres pi ces lectriques et causer une explosion e Retirez tous vos objets m talliques bagues bracelets montres etc lorsque voustravaillez avec des batteries Les batteries pourraient produire un court circuit assez puissant pour souder des objets causant une br lure grave e Si vous devez enlever la batterie retirez toujours la borne n gative de terre de la batterie en premier Assurez que tous les accessoires soient teints pour ne pas provoquer d tincelle e N utilisez que des o
30. ect the date of purchase the place of purchase and the Purchaser s name address and telephone number should also be included If upon the Warrantor s examination the defect proves to be the result of defective material or workmanship the equipment will be repaired or replaced at the Warrantor s option without charge and returned to the Pur chaser at the Warrantor s expense Contiguous US and Canada only No refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or water immersion No other express warranty is hereby given and there are no warranties which extend beyond those described herein This warranty is expressly in lieu of any other expressed or implied warranties including any implied war ranty of merchantability fitness for the ordinary purposes for which such goods are used or fitness for a particu lar purpose or any other obligations on the part of the Warrantor or its employees and representatives There shall be no responsibility or liability whatsoever on the part
31. ection 1 General Safety before starting installation 2 PRECAUTIONS WHEN WORKING WITH CHARGE CONTROLLER MODEL NO SCC 30AB If two or more solar panels are connected in series parallel make sure that the sum of the Short Circuit Current ratings of all panel strings does not exceed 80 of the Charge Controller s current rating e 24 Amps for the 30 Amp Charge Controller The Open Circuit Voltage of the solar array i e the maximum voltage across the array should not exceed 50V gt Block Diagram of Installation Fig 4 1 10 1 2 BUCO gre Read the manual in detail and understand the installation procedure Open the packaging and check to make sure that all parts have been received as per the List of Components page 5 Arrange for the required tools to carry out the installation A sample list of tools not exhaustive is provided in Section 4 Determine the mounting location of the solar panel s on the roof of the RV Mount the Charge Controller at the desired location see Section 6 Pass the cable from the solar panels to the interior of the RV See Section 7 Wire the battery to the Charge Controller through fuse and then the solar panel to the Charge Controller ensuring correct polarity is observed See Section 7 Secure the solar panel to the RV roof See Section 7 Fuse within 7 of battery post Fig 4 1 Installation Block Diagram Required Tools Required Materials a
32. er at STC Pmax Maximum Power Voltage Vmp Maximum Power Current Imp Open Circuit Voltage Voc Short Circuit Current Isc Module Efficiency Type of Cells No of Cells Maximum System Voltage Series Fuse Rating Terminal Box Operating Temperature Dimensions Weight STC Temperature Coefficient of Current Isc Temperature Coefficient of Voltage Voc Temperature Coefficient of Power Pmax 4 150W Panel with SRV 150 30A Solar Charging Kit 150 W x 396 18 38V 8 16A 22 68V 8 82A 15 42 Polycrystalline 36 100W Panel with SRV 100 30A Solar Charging Kit 100W 3 19 29V 5 18A 22 93V 5 81A 15 10 Monocrystalline 36 UL 1703 600VDC IEC 61215 16730 1000VDC 15A 10A IP 65 with 3 Bypass Diodes Cable 4mm with MC4 Compatible Connectors 40 C to 85 C 40 F to 185 F 660 x 1474 x 35 2mm 26 x 58 03 x 1 39 in 12 Kg 26 4 Ib 552 x 1200 x 35 2mm 21 73 x 47 25 x 1 39 in 8 Kg 17 63 Ib Irradiance Level 1000 W M Spectrum AM 1 5 Cell Temperature 25 C 77 F 0 08 C 0 34 C 0 43 C 0 04 C 0 33 C 0 37 C Details of Charge Controller SCC 30AB Please refer to the Owner s Manual enclosed with the Charge Controller Details of components included in the Kits are given below Table 2 2 Serial No 1 2 3 4 4 1 4 2 10 11 12 13 14 15 16 17 18 List of Components Description 100W Solar Panel 150W So
33. es d un panneau solaire sont aliment es par une bo te de jonction tanche l eau Des fils de taille appropri e sont branch s la bo te de jonction pour des autres connexions Chaque panneau solaire compris dans ces trousses sont fournis avec environ 90 cm de fils Positif et N gatif qui sont pr connect s la bo te de jonction Les extr mit s libres des fils sont termin es avec un type de connecteur accouplement sp cial pour faciliter l extension de ces fils pour des autres connexions Les connecteurs accouplement utilis s pour les 90 cm de fils fournis avec les panneaux solaires et aussi pour les fils d extension s par s se d taillent comme la suivante S rie Solarline MCA fabriqu e par Multi Contact Information G n rale sur le Syst me de Connexion MC4 Le syst me de connexion MC4 est compos de connecteurs m les et femelles Ce syst me est facile installer et utilise un type de collier de verrouillage pour s curiser les deux connecteurs correspondants ce qui vite un d saccouplement involontaire En outre les contacts d accouplement sont tanches prot geant des intrusions de la poussi re et de l eau Les sp cifications sont les suivantes Diam tre du contact Y 4 mm e Courant nominal maximal 30 A Tension maximale du syst me 1 000 V Indice de protection relative l tanch it lorsque connect et correctement verrouill IP67 Plage de temp rature 40 C 90 C
34. et de la trousse de connecteurs ramifi s MC4 SBC 2 vendus s par ment Cette disposition est possible si les deux panneaux solaires doivent tre install s c te c te Les fils de sortie des deux panneaux solaires sont d abord mont s en parall le en utilisant les connecteurs MC4 M les et Femelles Les sorties des connecteurs sont ensuite reli s aux fils SCW 20 2 pour la connexion au circuit ext rieur photovolta que Connexion de Deux Panneaux Solaires en Parall le Lorsqu ils sont S par s par une Distancee Fig 3 5 a Trousse SBC 2 4 nie T Connecteur Connecteur MC4 rousse MC4 m le femelle Trousse SCW 20 2 B l Mn adu EL 1 Il aaa 1 AS Ici a cS il I i pa Au Contr leur i Wt AEe i I 1 de Charge ErE 27 LE Lal E Connecteur It 2 E MC4 I al femelle L m le l La Fig 3 5 Connexion de Deux Panneaux Solaires en Parall le Lorsqu ils sont S par s par une Distance La Fig 3 5 ci dessus illustre l arrangement pour le raccordement de deux panneaux solaires en parall lequi sont s par e par une longue distane Dans ce cas il faudra e Les fils de connexion SCW 20 2 2 ensembles un ensemble est fourni avec la trousse le deuxi me doit tre command s par ment e Un connecteur ramifi MC4 Male et Un connecteur ramifi MC4 Femelle qui sont vendus s par ment dans un kit optionnel Mod le SBC 2 Un conne
35. ettes de verrouillage 1 enfichables 5 du connecteur MCA femelle DA correspondant Fig 3 2 3 D tendeur Sceau de tension NO L GENDE La Fig 3 2 Connecteur MC4 Femelle marqu La Fig 3 2 3 l encart d accouplement femelle 4 Des languettes de verrouillage enfichables pour 3 l accouplement avec les fentes 2 du connecteur MCA M le Fig 3 1 5 D tendeur Sceau de tension 5 4 D Connexions et Fils de Sortie sur le Panneau Solaire La Fig 3 3 illustre les fils de sortie et connexions du panneau solaire Les fils de sortie de la bo te de jonction du panneau solaire sont termin s avec un connecteur MC4 soit m le pour un et femelle pour l autre Le fil Positif est termin par un connecteur MCA Femelle d sign par et le fil N gatif est termin par un connecteur MCA M le d sign par Mise En Garde Lorsque la surface du panneau solaire est expos e au soleil une tension continue apparait aux bornes de sortie le transformant en source de tension active Par exemple un panneau solaire nominal de 24 V peut g n rer une tension en circuit ouvert d environ 45 VCC qui peut produire un choc lectrique Plusieurs panneaux solaires connect s en s rie pour augmenter la tension de sortie g n reront des tensions plus lev es qui risquent d tre mortelles Pour viter tout risque de choc lectrique lors de l installation s assurer que le panneau solaire soit recouvert
36. g 8 1 le fil photovoltaique Positif est connect la borne Positive du r gulateur de charge d sign e PV le fil photovoltaique N gatif est reli la borne n gative du r gulateur de charge d sign e PV Inverser la polarit endommagera le r gulateur de charge et les dommages r sultants ne seront pas couverts parla garantie Mise En Garde viter de mettre des objects pointus chauff s ou abrasifs sur le parcours du c blage 16 Connexion des Batteries en S rie y N Cable A Batterie 1 Batterie 2 Batterie Batterie de 6V de 6V R gulateur de charge solaire SCC 30AB vue arri re Cable B La Fig 9 1 Connexion en S rie Lorsque deux ou plusieurs batteries sont branch es en s rie leurs tensions s accumulent mais leur capacit AH reste la m me La Fig 10 1 ci dessus illustre 2 batteries de 6V 200 Ah branch es en s rie pour former une banque de batteries de 12V avec une capacit de 200 AH La borne Positive de la Batterie 1 devient la borne Positive de la banque de 12V La borne N gative de la Batterie 1 est reli e la borne Positive de la Batterie 2 La borne N gative de la batterie 2 devient la borne N gative de la banque de 12V Connexion des Batteries en Parallele G N Cable A Batterie 1 Batterie 2 Batterie 3 Batterie 4 Batterie de 12V R gulateur de charge solaire SCC 30AB vue arri re Cable B
37. ions are as follows e Contact diameter 4 mm Maximum rated current 30A Maximum system voltage 1000 V Degree of ingress protection when connected and properly locked IP67 Temperature range 40 C to 90 C MC4 Connectors Figs 3 1 3 2 The MC4 Connectors mentioned in this manual have been designated Male and Female based on the characteristics of the mating contact inserts inside the terminals In the MCA Male Connector Fig 3 1 the internal mating contact insert 1 Fig 3 1 is a male pin It has two slots 2 of Fig 3 1 for insertion of the two snap in type of locking tabs 5 of Fig 3 2 of the MC4 Female Connector Fig 3 2 for firm mating connection This connector is marked In MC4 Female Connector Fig 3 2 the internal mating contact insert 4 of Fig 3 2 is a female cylindrical socket It has two snap in type of locking tabs 5 of Fig 3 2 that are inserted into the two slots 2 of Fig 3 2 in the MC4 Male Connector Fig 3 1 for firm mating connection Wire is crimped to the contact inserts 1 and 4 of Fig 3 2 using a special purpose crimping tool designed for MCA connectors After the wire has been crimped the contact insert is required to be seated securely inside the housing and the strain relief seal 3 of Fig 3 1 amp 3 2 is to be tightened fully to provide a water tight seal LEGEND Fig 3 1 MC4 Male connector marked Fig 3 1 1 Male Contact Insert 2 2 Slots for accepting
38. lar Panel 30A PWM Charge Controller Model SCC 30AB Solar Panel Connecting Wires Kit Model SCW 20 2 consisting of Positive PV Extension Wire 20 ft length AWG 12 Male MC 4 Connector on one end and bare on the other Negative PV Extension Wire 20 ft length AWG 12 Female MC 4 Connector on one end and bare on the other 5 Hole Mounting Bracket for fixing Panel to RV Roof other structure Flange Bolt 1 4 20 x 3 4 Hex Stainless Steel For fixing panel frame to Mounting Bracket Srl 5 Flat Washer 1 4 Stainless Steel Under Flange Bolts Srls 6 and 10 Locknut 1 4 Hex Stainless Steel Nylon Insert For Flange Bolt Srl 6 Well Nut Nut size 1 4 20 Length 1 Shank Dia 1 2 For fixing Mounting Bracket Srl 5 to RV roof other structure Flange Bolt 1 4 20 x 1 4 Hex Stainless Steel For fixing Mounting Bracket Srl 5 to Well Nut Srl 9 Cable Clamp For PV Extension Wires Srls 4 1 amp 4 2 Self Tapping Screw 8 Philips For Cable Clamp Srl 11 Cable Tie for PV Extension Wires Srls 4 1 amp 4 2 Insulated Battery Ring Terminal Stud Size 5 16 Wire Size AWG 10 to 12 For crimping to wiring from Charge Controller to the battery Insulated Fork Terminals for AWG 10 to 12 wire 2 pcs for crimping to bare ends of PV Extension Wire Srl 4 1 and 4 2 for connection to Charge Controller Srl 3 2 pieces for crimping to bare ends of battery wires for connection
39. le B Fig 9 1 Series Connection When two or more batteries are connected in series their voltages add up but their Ah capacity remains the same Fig 9 1 above shows 2 pieces of 6V 200 Ah batteries connected in series to form a battery bank of 12V with a capacity of 200 Ah The Positive terminal of Battery 1 becomes the Positive terminal of the 12V bank The Negative terminal of Battery 1 is connected to the Positive terminal of Battery 2 The Negative terminal of Battery 2 becomes the Negative terminal of the 12V battery bank Parallel Connection of Batteries C N Cable A Battery 1 Battery 2 Battery 3 Battery 4 Solar Charge Controller SCC 30AB rear view Fig 9 2 Parallel Connection When two or more batteries are connected in parallel their voltage remains the same but their Ah capacities add up Fig 9 2 shows 4 pieces of 12V 100 Ah batteries connected in parallel to form a battery bank of 12V with a capacity of 400 Ah The four Positive terminals of Batteries 1 to 4 are paralleled connected together and this common Positive connection becomes the Positive terminal of the 12V bank Similarly the four Negative terminals of Batteries 1 to 4 are paralleled connected together and this common Negative connection becomes the Negative terminal of the 12V battery bank 17 Series Parallel Connection of Batteries String 1 String 2 Battery 1 Battery 2 Battery 3 Battery 4 6V Battery 6V B
40. le Placez le panneau dans le sens de la longueur afin de r duire la charge exerc e par le vent sur le VR C N Fil Negatif avec connecteur MC4 Femelle d sign par V Fil Positif avec connecteur MCA M le d sign par E La Fig 8 5 Kit de fils de connexion SCW 20 2 Deux fils d extension photovoltaiques pr assembl de 6 m de calibre 12 AWG Positif et N gatif sont compris voir la Fig 8 5 Les fils ont des connecteurs MC4 sur une extr mit pour se connecter au panneau solaire et une extr mit d nud e de l autre c t pour la connexion au r gulateur de charge Les fils sont marqu s 4 et pour l identification de la polarit Veuillez lire la section 3 pour le raccordement des c bles d extension aux panneaux a S Couvercle de l vent de R frig rateur Panneau Grille Solaire d vacuation d air La Fig 8 6 Entr e d extension PV par l vent du VR 15 10 11 12 La paire de fils du panneau solaire peut tre achemin e l int rieur du VR par l vent du r frig rateur sur le toit Trouver ou l vent du r frig rateur est situ sur le toit du VR Voir la Fig 8 6 Choisir un emplacement appropri pour l installation du panneau solaire de pr f rence aussi pr s de l vent que possible La surface de montage doit tre suffisamment solide pour supporter les supports de montage le panneau solaire et la surcharge du vent E
41. le n importe quel lubrifiant standard minimisera l apparition du grippage du filetage Fixer les supports de montage La Fig 7 2 au cadre du panneau solaire pr alablement positionn l aide de l ouverture rainur e et le boulon paulement de po 20 x 34 po le contre crou et la rondelle plate La Fig 7 1 l aide d une cl de 7 16 po serrer les crous pour fixer les supports de montage sur le panneau photovolta que La torque de serrage recommand e est de 15 lbs Positionner le panneau avec les supports de montage attach s l endroit d sir sur le toit du VR et marquer la position d sir e du trou de montage en utilisant un marqueur appropri et en tracant le trou sur le support de montage S assurer que la surface de montage soit suffisamment solide pour supporter les supports de montage le panneau solaire et la surcharge du vent Les trous de centre et d extr mit sur les supports de montage Fig 7 2 sont dimensionn s pour accepterles pi ces de fixation de po fourni avec l appareil Si l utilisation de pi ces de fixation de taille plus grande 3 8 po est d sir e les trous 2 et 4 peuvent tre utilis s crou douille pour l ancrage du panneau solaire au toit du VR 12 6 Un crou douille est une cheville en caoutchouc n opr ne r sistant avec une bride l extr mit sup rieure et un crou encastr en laiton mont dans l al sage l extr mit inf rieure La Fig
42. liste d outils requies non exhaustive est fournie dans la Section 4 D terminer l emplacement de la fixation du ou des panneaux solaires sur le toit du VR Installer le r gulateur de charge l endroit d sir voir la Section 6 Faire passer le c ble par des panneaux solaires l int rieur de la VR voir la Section 7 Filer la batterie au r gulateur de charge puis le panneau solaire au r gulateur de charge tout en s assurant que la polarit est correcte voir la Section 7 Fixer le panneau solaire sur le toit du v hicule voir la Section 7 Panneau Solaire i R gulateur de Charge Solaire Fusiblea 18cm 3 de la borne de batterie La Fig 4 1 Bloc Diagramme de l installation Outils Requis Mat riaux Requis a 9 10 Chasse clou ou Poincon E O UT pwn gt 1 Du silicone ou tout mastic de toit convenable Contactez votre Tournevis Pointe Cruciforme repr sentant ou magasin de VR pour une recommandation Cl de 7 16Po relative un produit d tanch it convenable pour le mat riel Cl de 3 8Po sp cifique du toit de votre v hicule Pince d nuder 2 Lubrifiant anti grippage pour emp cher le grippage du filetage de tous les l ments de fixation en acier inoxydable Outil Sertissage Aures hes n M 9 expos s l environnement ext rieur Celui ci devrait tre Perceuse Main disponible la plupart des quincailleries ou magasins de pi ces Foret
43. male MC4 mating connector marked that mates with the female MC4 mating connector marked on the Positive wire of the panel Similarly the Negative extension wire has a female MC4 mating connector marked that mates with the male MC4 mating connector marked on the Negative wire of the panel y Female MC4 mating connector marked for Negative PV Extension Wire I Male MC4 mating To Charge connector marked Controller Male MC4 mating connector marked for Positive PV Extension Wire P4 Female MC4 matin connector marked Fig 3 3 Connecting extension wires to the output wires of solar panel 1 The Positive wire of the solar panel is terminated with a MC4 Female Connector marked Connect this to the MC4 Male Connector marked that is attached to the Positive PV Extension Wire Make sure that the locking tabs snap in for a firm connection The bare end of the Positive extension Wire will now be of Positive polarity Use a piece of red sleeve or red tape near the bare end for identification as the Positive wire 2 The Negative wire of the solar panel is terminated with a MC4 Male Connector marked Connect this to the MC4 Female Connector marked that is attached to the Negative extension wire Make sure that the locking tabs snap in for a firm connection The bare end of the Negative PV Extension Wire will now
44. n the side of the vent and insert a rubber grommet not provided Route the wire pair carefully to the Charge Controller through the hole Use appropriate sealant as recommended by your local RV dealer to ensure the penetration at the side of the vent is watertight B Through the vent screen Route the wire pair through the vent screen grid holes Widen the screen grid holes if necessary 9 Use the cable clamps with 8 self tapping screws and tie wraps at regular intervals of the wire route from the solar panel to the Charge Controller to hold the cables in place for a neat finish Tuck any excess wire under the refrigerator vent cover y Warning A Avoid sharp heated or abrasive material on the cable route 16 10 Replace the refrigerator vent cover and secure with the retained hardware 11 Crimp the bare end of the wires with the fork terminals provided Fig 8 3 12 Insert the terminals into the appropriate terminal on the Charge Controller Fig 8 1 Positive PV lead is connected to the Positive terminal marked PV of the Charge Controller and the Negative PV lead is connected to the Negative terminal marked PV of the Charge Controller Reverse polarity connection may damage the Charge Controller and the resulting damage will not be covered by warranty Series Connection of Batteries G N Cable A Battery 1 Battery 2 9 6V Battery Solar Charge Controller SCC 30AB rear view Cab
45. ned in the manual Make sure the solar panels and batteries are disconnected from the Charge Controller before installing the Charge Controller 4 The Charge Controller should ideally be located in an area relatively close to the battery g9 8 9 The Charge Controller should be mounted indoors in a dry location The Charge Controller is designed to be flush mounted on a wall or cabinet so that the wiring at the back can be accessed Allow adequate spacing 2 3 inches behind the unit to accommodate the Charge Controller and the wiring Using the cut out template provided with the Charge Controller mark the cut out on the installation surface and the location of the mounting holes Using a hand drill and suitable drill bit drill the mounting holes Using a jig saw or suitable cutting tool cut the material out from the installation surface 10 After wiring the Charge Controller terminals see Section 7 on wiring fix the mounting plate to the installation surface using the screws provided with the Charge Controller 7 x 19 5 8 Flat Head Tapping Screws Philips Drive 11 Stainless steel can be subject to a process called thread galling in which bolts can twist off and or the bolt threads seize to the nut s thread Apply Anti galling Lubricant available at most hardware or auto parts stores to all the stainless steel fasteners before installation If anti galling lubricant is not available any standard lubricant
46. nlever le couvercle d a ration pour acc der l ouverture des conduits et garder les ferrures de fixation de l vent en toute s curit puisque le couvercle d a ration doit tre remis apr s que les fils auront t achemin s Les fils du panneau solaire peuvent tre achemin s soit par A un trou dans le c t de l vent Percer un trou appropri sur le c t de l vent et ins rer un joint en caoutchouc non fourni Acheminer avec soins la paire de fils au r gulateur de charge travers le trou Utiliser l enduit d tanch it appropri tel que recommand par le d taillant du VR pour assurer que la p n tration sur le c t de la chemin e est tanche B par la grille d vacuation d air Acheminer la paire de fils travers les trous de la grille largir les trous de la grille si n cessaire Pour une finition soign e utiliser les serre c bles avec des vis autotaraudeuses et des colliers de serrage intervalles r guliers sur le parcours du c blage partir du panneau solaire jusqu au r gulateur de charge pour maintenir les c bles en place Enfouir tout exc dent de fil dans le couvercle de l vent de r frig rateur Remettre le couvercle de l vent de r frig rateur et fixer le avec les ferrures de fixation conserv es Sertir l extr mit d nud e des fils avec les cosses fourche fournies La Fig 8 3 Ins rer les extr mit s fourchues dans la borne appropri e du r gulateur de charge La Fi
47. o the SCW 20 2 wires for connecting to the external PV circuit Connecting Second Solar Panel in Parallel When Separated by a Distance Fig 3 5 SBC 2 Kit MC4 Female Male MC4 Branch Connector Ol SCW 20 2 Kit onnector _ bet a l LL U E ae I AS i La To Charge Controller j CRE I I MC4 Male Presse Branch Connector A Female MC4 Connector Fig 3 5 Connecting two solar panels in parallel that are separated by an extended distance Fig 3 5 above shows an arrangement for connecting second solar panel in parallel that is separated by an extended distance In this case the following will be required e SCW 20 2 Connecting Wires Kit 2 sets one set is provided with this kit Second set has to be ordered separately e One MCA Male Branch Connector and one MC4 Female Branch Connector sold separately as an optional kit Model No SBC 2 Kit One MCA Male Connector and one MC4 Female Connector sold separately as an optional kit Model No MCA4 2 In this case one Connecting Wire Kit SWC 20 2 and the optional MC 4 Connectors Kit MCA 2 are first used to bridge the extended distance between the panels The optional Branch Connector SBC 2 Kit is used to parallel the two solar panels The second Connecting Wire Kit SWC 20 2 is used to connect to the external PV circuit INSTALLATION OVERVIEW y Warning 1 SAFETY Please read S
48. of the Warrantor or its employees and repre sentatives for injury to any persons or damage to person or persons or damage to property or loss of income or profit or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment including any possible failure of malfunction of the equipment or part thereof The Warrantor assumes no liability for incidental or consequential damages of any kind Samlex America Inc the Warrantor www samlexamerica com 20 NOTES NOTES NOTES Contact Information Toll Free Numbers Ph 800 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders samlexamerica com ES samlexamerica samlexsolar A Division of Samlex America Inc La Trousse Guide de en de Recharge l Utilisateur SU Solaire d utiliser votre SRV 100 30A trousse SRV 150 30A GUIDE DU PROPRI TAIRE 10 11 Consignes de S curit Description et Liste des Composants Syst me de Connexion pour le Raccordement des Panneaux Solaires
49. oulon engag eant l crou encastr en laiton La Fig 7 4 L crou douille est ins r dans un trou pr perc avec sa bride contre la sur face ext rieure II n est pas n cessaire d acc der la surface int rieure WS AS v ZUNS SES La Fig 7 7 Install dans un trou borgne dans un mat riau solide le corps de l crou douille dilate pour se loger fermement contre les parois du trou assurant ainsi une fixation s re et s curitaire 7 Pour installer les crous douilles percer l aide d un foret de po des trous de 1 po de profondeur aux positions marqu es Veiller se que le forage ne nuise pas au c blage existant 8 Appliquer g n reusement du silicone ou un produit d tanch it appropri recommand par le d taillant de votre VR aux trous perc s pour les imperm abiliser 9 Ins rer l crou douille de Y po dans les trous perc s de sorte que seulement la bride reste au dessus de la surface du toit La Fig 8 4 10 Fixer les supports de montage la surface du toit par l insertion d un boulon bride dentel e de Y x 1 po dans l crou douille La Fig 8 5 Serrer l aide d une cl de 3 8 po une torque de serrage recommand de 15 Ibs Lorsque le boulon bride dentel e est viss dans l crou douille le mat riau environnant l crou douille va gonfler l gerement fixant la structure sur le toit du VR Fig 8 6 8 8 11 Veiller ce que tous le
50. pair of 20 foot AWG 12 pre assembled cables with Multi Contact MC4 Male and Female Connectors is provided to connect the solar panel to the Charge Controller After making sure that sufficient length is available to wire the solar panel to the Charge Controller any excess wire may be used to wire the battery to the Charge Controller Please refer to wiring layout at Fig 8 1 below Wiring from Battery to Charge Controller e Use AWG 12 for up to 6 ft and AWG 10 for up to 10 ft to limit voltage drop to 2 at maximum 10A e Mark the cables to differentiate between Positive and Negative Make sure the Positive terminal marked of the battery is connected to the Positive terminal marked BAT of the Charge Controller and the Negative terminal marked of the battery is connected to the Negative terminal marked BAT of the Charge Controller SCC 30AB Fig 8 1 If you are not sure use a DC voltmeter to determine the polarity of the battery bank Reverse polarity connection may damage the Charge Controller and the resulting damage will not be covered by warranty e 4 pieces of Fork Terminals Fig 8 3 have been supplied for crimping on to the wire ends on the Controller side 2 pieces of Ring Terminals Fig 8 2 have been provided for crimping on the wire ends on the battery side Use Inline ATC style Fuse Holder of 10A ATC 10 fuse on the battery end of the Positive cable Fig 8 1 NOT SUPPLIED The Fuse Holder comes
51. r vitres si n cessaire e Assurez vous que tous les l ments structurels les fixations m caniques et les connexions lectriques soient s rs propres et exempts de corrosion e V rifier et maintenir le niveau d lectrolyte de la batterie intervalles r guliers conform ment aux e recommandations du fabricant de la batterie si un accumulateur au plomb acide pile liquide inond e est utilis e e V rifiez et remplacez les composants endommag s au besoin 19 Garantie Les trousses de recharge solaire et d extension Samlex SRV 100 30A et SRV 150 30A fabriqu es par Samlex America Inc le Garant sont garanties d tre exemptes de d fauts de fabrication et de mat riaux dans des conditions normales d utilisation et de service Cette garantie est en vigueur partir de la date d achat par l utilisateur l Acheteur Les p riodes de garantie pour les diff rents composants des trousses Panneau solaire de 100W 150W Garantie de 5 ans sur la fabrication du produit Garantie de 12 ans sur la puissance de sortie 90 Garantie de 25 ans sur la puissance de sortie 80 R gulateur de charge solaire Samlex de 30A Garantie de 5 ans sur la fabrication du produit Mod le SCC 30AB Ferrures de fixation et c blage Garantie de 5 ans sur la fabrication du produit Pour une r clamation sur la garantie l acheteur doit contacter le lieu d achat pour obtenir un num ro d autorisation du retour La pi ce ou l unit
52. rs samlexamerica com ES samlexamerica
53. s Thus such equipment should not be used in areas where there are inflammable materials or gases requiring ignition protected equipment These areas may include spaces containing gasoline powered machinery fuel tanks battery compartments etc Precautions When Working With Batteries Batteries contain very corrosive diluted Sulphuric Acid as electrolyte Precautions should be taken to prevent contact with skin eyes or clothing Batteries generate Hydrogen and Oxygen during charging resulting in evolution of explosive gas mixture Care should be taken to ventilate the battery area and follow the battery manufacturer s recommendations Never smoke or allow a spark or flame near the batteries Use caution to reduce the risk of dropping a metal tool on the battery It could spark or short circuit the battery terminals or other electrical parts and could cause an explosion Remove metal items like rings bracelets and watches when working with batteries Batteries can produce a short circuit current high enough to weld a ring or the like to metal and thus cause a severe burn If you need to remove a battery always remove the Ground Negative terminal from the battery first When connecting the battery connect the Ground last Make sure that all the accessories are off so that you do not cause a spark Use properly insulated tools when making battery connections Precautions When Working With Solar Panels With the incidence of sunlight or o
54. s boulons et supports de montage soient couverts d une couche g n reuse d enduit d tanch it pour VR tel que recommand par le d taillant Va Support a Montage 14 20 x 11 Boulon Bride c Module Solaire Va Rondelle Plate crou Douille 7 Le mat riau en caoutchouc de la douille se dilate quand le boulon est serr pour ancrer solidement V les support de montage Mat riau de toit du v hicule jusqu env 3 8 po d paisseur N La Fig 7 8 Fixer le support de montage 5 trous sur le toit du VR 13 Veuillez vous r f rer au sch ma de c blage la Fig 8 1 Remarquez Les tailles de c bles et de fusibles recommand en dessous sont appropri es pour un panneau de 1006150w avec une capacit de courant maximal de 10A Mise En Garde 1 La batterie doit tre connect e au r gulateur de charge avant que le panneau solaire ne soit connect au r gulateur de charge 2 Utilisez la taille de fusible appropri e dans le c ble Posistif de la batterie pour emp cher le risque de provo quer un incendie cause d un court circuit dans les c bles Une paire de c bles pr assembl s de 6 m avec des connecteurs Multi Contact MC m les et femelles est fournie principalement afin de communiquer le panneau solaire au r gulateur de charge Apr s avoir assur que la longueur est suffisante pour raccorder le panneau solaire au r gulateur de charge tout exc dent de fil peu
55. se en Garde s Faites attention de ne pas court circuiter la batterie s e P O Porte Fusible Panneau Solaire P La Fig 8 2 La Fig 8 3 n Fusible Cosses Cosses 4 Nattes AWG 12 en ligne circulaire fourche pour Voir Fig 8 4 pour le le c t du La Fig 8 4 La Fig 8 1 Sch ma de c t de la contr lleur Porte fusible style ATC enligne et fusi C blage Batterie batterie ble de ATC 10 de 10 Amp pas fourni 14 Utilisez le fusible style ATC enligne de 10 Amp avec le porte fusible La Fig 8 4 au plus pr s possible de la batterie Panneau Solaire au R gulateur de Charge 1 D terminer l emplacement du panneau solaire la fixation sur le toit du VR En positionnant les panneaux viter de les mettre l ombre des obstacles environnants tels que les vents climatiseurs antennes de TV etc Autant que possible positionnez les panneaux afin de minimiser la longueur du c blage entre le panneau solaire et le r gulateur de charge Placez le panneau au moins 20 25 cm des bords du toit du VR et laisser suffisamment d espace pour pouvoir se d placer autour du panneau et acc der aux composants de montage S assurer que l paisseur de la toiture l emplacement de l installation est au moins12 5 mm d paisseur et que le mat riau est suffisamment solide pour fournir un soutien m canique au panneau solaire et au mat riel de montage pour une r sistance au vent ventuel
56. sly to the drilled holes for water proofing 9 Insert the 4 Well Nut into the drilled holes so that only the flange section remains above the roof surface Fig 7 4 10 Fasten the mounting brackets to the roof surface by inserting the x 1 serrated flange bolt into the Well Nut Fig 7 5 Tighten using a 3 8 wrench to a recommended torque of 15 Ibs When the serrated flange bolt is screwed into the Well Nut the material surrounding the well nut bulges slightly securing the structure to the RV roof Fig 7 6 amp 7 8 11 Make sure all bolts and mounting brackets are covered by good amounts of suitable RV sealant recommended by your local RV dealer ye e Mounting Bracket 14 20 x 14 Flange Bolt c Solar Module Va Flat Washer M RV roof material up to approx 3 8 thickness Well Nut N Rubber bushing material expands when bolt is tightened to securely anchor hardware Fig 7 8 Attaching 5 hole mounting bracket to RV Roof 13 Please refer to wiring layout shown in Fig 8 1 NOTE Wiring and Fuse sizes recommended below are based on use of a single 100 150W solar panel with maximum current handling capacity of 10A Caution l 1 The battery must be wired to the Charge Controller before the solar panel is connected to the Charge Controller 2 Use appropriate size of fuse in battery Positive Cable to protect against fire hazard due to short circuit in the battery cables A
57. t tre utilis pour c bl la batterie au r gulateur de charge Veuillez vous r f rer la figure 8 1 en dessous Connexion de la batterie au Contr leur de Charge Marquer les c bles afin de pouvoir distinguer entre les c bles Positifs et N gatifs S assurer que la borne Positive de la batterie d sign e par est reli e la borne Positive du r gulateur de charge d sign e BAT et la borne N gative de la batterie d sign e est reli e la borne N gative d sign e BAT du r gulateur de charge SCC 30A8 La Fig 8 1 En cas de doute utiliser un voltm tre de courant continu pour d terminer la polarit de la banque de batteries Un inversement de la polarit endommagera le r gulateur de charge et les dommages r sultants ne seront pas couverts par la garantie Sertir les cosses fourche isol es fournies La Fig 7 1 3 une extr mit des fils conducteurs Positif et N gatif de la batterie 4 cosses fourche La Fig 8 3 sont fourni pour tre cr per sur les bout de c bles du contr leur de charge et 2 cosses circulaires La Fig 8 2 tre cr per sur le c t de la batterie Utilisez le porte fusible style ATC enligne pour un fusible de ATC 10 de 10 Amp sur le c t batterie du c ble positif La fig 8 1 qui n est pas fourni Le porte fusible est livr avec des nattes de 10 cm AWG 12 pissez une natter au bout du c ble positf et utilisez l autre pour la connexion la batterie Mi
58. ther light sources on solar panels a voltage appears at the output terminals of the solar panel turning it into a source of electricity To avoid a shock hazard make sure the solar panel is covered with an opaque dark material such as paper cloth during installation Do not make contact with the terminals when the panel is exposed to sunlight or any other light sources Solar Charging Kits SRV 100 30A and SRV 150 30A provide clean green silent and sustainable source of solar based DC power to charge 12V Lead Acid batteries Each kit comes with the following High efficiency solar panel with MC 4 Connectors e State of the art 30A Charge Controller e Connecting Wires with mating MC 4 Connectors e Mounting Brackets e Installation Hardware Details of Solar Panel Design Features High Conversion Efficiency generates more energy per square meter Protective Bypass Diodes avoid effects of partial shading e Weatherproof Junction Box and Connectors Optical Low Iron Tempered Glass EVA Resin and Aluminum Frame for operation in outdoor wet and marine applications Highest manufacturing standards Test ID for each panel e Strong frame withstands high wind force Applications Residential Roof top Systems e Commercial Industrial Building Roof top Systems Ruralarea applications Other on grid and off grid applications e Automotive RV and Marine Table 2 1 Specifications of Solar Panels Parameter Nominal Maximum Pow
59. utils proprement isol s pour faire des raccordements de batterie Pr cautions prendre en travaillant avec les panneaux solaires Avec l incidence de la lumi re du soleil ou autres sources de lumi re sur les panneaux solaires une tension apparait aux bornes de sortie du panneau solaire pour en faire une source d lectricit Pour viter un risque d lectrocution assurez vous que le panneau solaire soit recouvert d un mat riel opaque noir tel que du papier tissu lors de l installation Ne touchez pas les bornes lorsque le panneau est expos la lumi re Trousse de Recharge Solaire SRV 100 30A et SRV 150 30A fournir une source propre verte silencieuse et durable de l nergie solaire DC bas e charger les batteries 12V au plomb Chaque kit Comprend e Panneau Solaire Haut Rendement e R gulateur de Charge de 30 Amp e Fils de Connexion Supports et Composants de Montage D tails du Paneau Solaire Caract ristiques de la Conception Haut Efficacit de Conversion g n rent plus d nergie par metre carr e Diode de blocage pour viter les effets de mi ombre Boite Jonction et Connecteurs r sistant aux intemp ries Verre Tremp Optique Compostion Faible en Fer R sine EVA et Cadre en Aluminium pour installations ext rieures et applications marines Haut Exigences pour la fabrication Chaque panneau est test fond Cadre fort capable de r sister des forces a oliennes lev es

Download Pdf Manuals

image

Related Search

Related Contents

MASlink Host Instruction Manual  Huawei HG556a User's Manual  Casio 2789 MA0309-EA User's Manual  Owner`s Manual (General)  Massive Paquero  Monitor SV Manual de Instalação Rev D  FRH-SD07T スターターキット取扱説明書[PDF:135.7KB]  HP BladeSystem c7000 enclosure + 4 x ProLiant BL460c G6  estudio de mercado  FRONT PANEL: BACK PANEL:  

Copyright © All rights reserved.
Failed to retrieve file