Home
7300 Manual (dick v1).PUB
Contents
1. 1 Push and hold the LED ENABLE button for five seconds The STOP LED will blink indicating the board is in learn mode 2 Cycle the gate three full times must read open and close limit switches each cycle The STOP LED will now stay illuminated 3 Adjust the current sensitivity pot to insure safe operation The current sensitivity may be readjusted at any time without relearning the board Periodically check the current sensitivity for safe operation 16 835 836 Control Board Parts Identification 34 damus Timer To Close Dual Gate Delay Current Sensitivity Adjustments Microprocessor ci ce p l f a A d gt m 7 Mo ix E a a a E a F Abbeedtaeeiaa 0 21 f ES x t i a i e e u iria Tu p SeN iriiri eii n C z il F _ TEE a e F Li tg Ma a C lt x4 m E OOO os oe we LED Enable amp Learn Mode Push Button O00 a s E Stop Circuit Jumper Control Board Reset Fire amp ETL Inputs Emergency Bypass Actuator Connector Reverse Battery Polarity Actuator Connector Slave Indicators Master 17 Actuator Connector Actuator Function Cable Orange Open Limit White Close Limit Black Motor positive on open negative on close Red Motor negative on open positive on close Green Common for bo
2. 4 Replace the operator and fasten to the pad 3 5 AULLILILILILIILILILI M NEXT ILITIITITITITITITITITITITITI Chain path Make sure the chain path clears all posts and obstacles Mounting Holes 4 TOP VIEW CHAIN BRACKET INSTALLATION STEP 1 Assemble chain bracket with 5 16 U bolt 8 hardware to each end of the gate as shown Do not tighten at this time STEP 2 Align the left chain bracket slot with the top teeth of the idler sprocket TIP f welding equipment is available tack weld the chain bracket to the gate on each end to prevent slippage Idler Sprocket Main Sprocket STEP 3 Align the right chain bracket slot with the bottom teeth of the main sprocket STEP 4 Tighten all hardware CHAIN amp CHAIN BOLT INSTALLATION STEP 1 Position the gate so that the operator is in the center of the gate Connect chain bolt to the chain bracket as shown on both ends of the gate STEP 2 Attach the chain to the chain bolt using the master chain link Do not tighten the chain bolts Note A chain breaking tool may be required to reduce the chain to the proper length CHAIN MAGNETS INSTALLATION 1 Align each magnet with the corresponding switch on the operator 2 Connect the battery and adjust the magnets for proper open amp close limits WARNING Always disconnect battery prior to relocating the magnet Limit Switch TIP f the gate automat
3. and exit 5 Will vehicles and trailers have sufficient room off roadway to operate any control devices such as keypads PARTS IDENTIFICATION 4 7 e NUN NY Operator 5 16 Washers Lock Nuts amp Nuts 8 each Chain Brackets 2 Magnetic Chain Limits with hardware 2 each 5 16 U Bolts 4 each Tm 40 Roller Chain 35 feet Moving Gate Can Cause Serious Injury or Death cramer MATFERET CHARGER c te oe Oi aag epa edie dep i e 3 273G CAUTION Signs 2 each 201 404C 5 Watt Solar Panel amp Bracket Automatic Battery Charger optional optional PAD INSTALLATION Direction of Openiny Y 1 dr SO ara Driveway shel A Pad Location Fig A Fig B Conduit requirements should be considered in the planning stage If electrical power is required a separate conduit should be installed for electrical only A certified electrician should be consulted for the proper conduit material Figure C amp D OPERATOR INSTALLATION Four 1 2 anchor bolts not supplied are recommended to mount the chassis The holes should be drilled with a 1 2 concrete drill bit A STEP 1 Set the operator on the pad as shown Align the sprockets 3 to 5 inches from the inside surface of the gate STEP 2 Mark the four mounting holes on the pad STEP 3 Remove the operator and drill the holes according to the anchor bolt manufacturers in structions STEP
4. gate gets closed and the MAS terminal switches and the device will power down 18 Adjustments TIMER TO CLOSE Adjusts time before gate automatically closes Adjustable 5 to 70 seconds DUAL GATE DELAY Adjusts delay between master and slave op eration 0 4 seconds 836 only for use with magnetic solenoid and other locking de vices CURRENT SENSITIVITY Increases or decreases the Auto Reverse sensitivity Push Buttons OPERATE When depressed activates the gate Used for initial installation and testing Hard Shutdown Reset Resets the operator when the gate current senses twice before fully opening or closing LED ENABLE When depressed activates LEDs for 15 minutes to assist in installation and troubleshooting Hold the push button down for five seconds to put the board in program mode Resets the microprocessor Returns processor to last known state Jumpers STOP CIRCUIT JUMPER When the STOP CIRCUIT program switch 5 must be ON JUMPER is connected the gate will operate normally STOP CIRCUIT JUMPER When a 3 button station is con program switch 5 must be OFF nected to the board the STOP CIRCUIT JUMPER must be re moved 19 Program Switches TIMER TO CLOSE TIMER TO CLOSE OPT SLAVE DISABLE SIREN DELAY OPEN CLOSE INPUT OPT LOCK TYPE COAST ENABLE Add PMA Olay SMART ACT Arritti 1 TIMER TO CLOSE 2 TIMER TO CLOSE OPT 3 SLAVE DISABLE 4 SIREN DELAY 5 STOP C
5. A P O LLO Gate Operators Inc Residential 8 Heavy Duty Commercial Slide Gate Operator INSTALLATION MANUAL 04 07 CONTENTS IMPORTANT SAFETY INSTRUCTIONS coooccccccoccccocnnnnonnnnnncnnnnnaronnnnnnronananennnnas 3 APRICAIONS aims Pre Installation Checklist inside il 5 Parts Identificati n nica 6 Rad IWS tat OM ide EET 7 Operator Installatlon iii 8 Chain Bracket Installation ooocccnncccnnniccnncncnncncnnonnrccnnrnnnanonannnnnrnnnanrnnnnnannnns 9 Chain amp Chain Bolt Installation cima ii 10 Chain Magnets Installation cars dodo 11 Left or Right Hand Operation oocococccccccccccccncnnccccnncnnnnnnnnnnnnnnnnnnnnnnnnos 12 Quick Release Operation ccccsssesssececeneeeeseeeceseeeueseseesseeeseeeeseesesessussess 13 Programming Instructions 2 vx dus rd 14 Control Board Connections sicario 15 SIMON CONNECHON peinada ciaci n 22 Radio Receiver Options isis 23 Warranty nano ib aa ls 24 IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of injury or death READ AND FOLLOW ALL INSTRUCTIONS Installation should be performed by a professional installer Required welding should be performed by a qualified welder Should electricity be required use a certified electrician only Any device that requires 120 Volts AC should be U L approved Review with the owner all safety concerns including gt Do not operate the gate unless area around gate is in full view gt Never let children operate
6. IRCUIT ENABLE 6 LOCK TYPE 7 COAST ENABLE 8 FREE EXIT OPT 9 DUAL GATE SYNC 10 SMART ACT OFF Gate does not automatically close Gate automatically closes from any position after opening Enables slave side dual gate use Siren optional active when gate is moving Must hold down open or close buttons to move gate Gate stops when button released For 12V mechanical solenoid locks 12V for 4 seconds on open cycle Gate will stop immediately when at Open or Close limit A free exit input will open gate from closed position or after a close cycle only Both gates operate at normal Speed slave slower than Master Off for 416E 416EX actuators slide gates 3500 or when slow down feature is not desired 20 ON Gate automatically closes Gate automatically closes only when completely open open limit engaged Disables slave side single gate use Siren optional starts 5 seconds before gate moves Normal operation Momentary open or close input runs gate to limit For 12V magnetic locks 12V when on close limit Gate will coast minimally when it reaches limits Recommended for 7500 slide operator only A free exit input will open gate from any position after an open or close cycle This feature will control the master gate to open or close at the same speed as the slave gate Used for 816E amp 816EX actuators only soft start 4 stop l Optional Device Inp
7. ery or connected as shown below receiver should be configured for 12VDC Multi Code Digi Code black gray gray red Allstar white Lift Master 4 N Heddolf Linear __ white silver common white gold Lift Master will require that the 12 24 jumper be set to 12 and the C M constant momentary jumper be set to C 23 A P O LLO Gate Operators Inc LIMITED TWO YEAR WARRANTY Apollo Gate Operators are warranted against defects for a period of 24 months from the date of purchase providing recommended installation y procedures are followed This warranty is in lieu of all other warranties B expressed or implied some states do not allow limitations on how long an d implied warranty lasts so this limitation may not apply to you and shall be considered void if damage was due to improper installation or use t connection to improper power source or if damage was caused by fire E flood or lightning The manufacturer will not be responsible for any labor y charges incurred in the removal or replacement of defective parts z In case of failure due to defective material or workmanship during the A warranty period the defective part will be repaired or replaced at the d manufacturer s option at no charge if returned freight prepaid New or factory rebuilt replacements may be used Replacement parts are warranted for the E remaining portion of the original warranty period The manu
8. facturer will pay a standard ground freight on the return of repaired or replaced items in warranty 24
9. guide for capacity of operation of operators only additional options may reduce the the daily usage Please note that the charge capability of solar panels will vary with different geographical locations All solar pan els and battery chargers are designed for use with a 12 volt battery 30 watt solar panel requires 5310 regulator ty fey d 6 Note Double the amount of solar panels for Dual Gate Operators 4 PRE INSTALLATION CHECKLIST The following checklist should be used before beginning installation Verify that the proper operator has been selected for this application Verify proper installation and operation of the gate 1 Are all rollers covered with a protective housing 2 Are the rollers servicable 3 Does the gate roll free and level 4 Will the gate require a locking device 5 Are the main posts sturdy enough to handle the gate amp operator Determine the general location of the operator chian brackets and solar panel if used 1 Is there a suitable location for the operator 2 Can the solar panel if used be mounted in an unobstructed area facing south 3 Will additional solar panel cable be required 4 Is electricity available if required Consider safety and access options Recommend if needed 1 Will there be chidren or animals in the area 2 Are safety loops edge switches or photo beam detectors required 3 How can the gate be opened in emergencies 4 How will visitors enter
10. ically opens after the close timer expires reverse the red amp black motor wires and reverse the orange amp white limit wires 11 Left or Right Hand Operation Apollo s line of slide gate operators are pre wired to open the gate to the right and close the gate to the left looking from the inside of the property If the operator is to be installed on the left side of the drive use wiring diagram B L ii T A R R AA L 2 E C E E CC Factory Hookup A AA K D D KK C E ECCE K D DKKD R E D O O R B O GW B R W G O E L R RH L E H RR D A A El A D E A C N ET K G NE C T E N K E N G E A B amp 4 Gate in closed position Gate in closed position operator operator 12 QUICK RELEASE OPERATION Engaged Pull amp turn 1 2 inch to disengage SUAE Programming Current Sensing The 835 836 control boards incorporate a safety feature that will put the op erator into a hard shutdown mode if the control board detects a current sense two consecutive times during a cycle This hard shutdown condition can only be reset by shorting the FIREBOX or UL connectors on the left side of the control board to ground This condition may also be reset by pressing the HARD SHUTDOWN RESET button located toward the upper right hand cor ner of the control board If a firebox is used in the installation The firebox door optional should be opened and closed to reset the contr
11. ol board The following instructions must be followed at installation for proper safety assurance All limits should be set before beginning this procedure This new procedure applies to revision 31 or higher firmware 1 Press and hold the LED ENABLE button for five seconds The STOP LED will blink indicating that the board is in learn mode 3 Cycle gate for 3 full cycles The STOP LED will stop blinking indicating that the board is now ready for normal operation 4 Test the auto reverse sensitivity to ensure maximum safety protection The current sensitivity adjustment pot may be adjusted to decrease or increase sensitivity COUNTER CLOCKWIS CLOCKWISE More sensitivity Less sensitivity Gate is easy to current Gate is harder to CURRENT CURRENT SENSE SENSITIVITY SENSITIVITY current sense 8 Refer to the 835 836 Operator Control Board Manual to set other options such as program switch options and close timer adjustments Installation is now complete Note Program switch 9 is no longer functional and the current sense may be readjusted at any time 14 APOLLO Firmware Version 31 and up 835 836 Gate Control Board 07 15 2005 2000000 Rev F ERE an SE E poe 15 PROGRAMMING INSTRUCTIONS Once the operator is installed or if the control board is replaced you will need to program the control board for proper current sensing The operator should be functional and the open and close limits set
12. or play with gate controls Keep the remote control away from children gt Always keep people and objects away from the gate NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE gt Periodically test the obstruction sensitivity to assure safe and proper operation Do not test sensitivity by standing between the gate and the hinge or stop post gt The CAUTION AUTOMATIC GATE signs should be clearly visible from both sides of the gate gt Always insure that the gate has closed securely before leaving area gt Arrange with local fire and law enforcement for emergency access Use the emergency release only when the gate is not moving A secondary entrapment device such as loop detectors edge switches and beam detectors are highly recommended and required to meet the UL325 standard Install control devices such as keypads far enough away 5 feet or further from any moving parts of the operator and gate to prevent possible injury Do not install control box where the gate can come in contact with person using the push button on side of control box Always disconnect the battery or power source when making adjustments or repairs to any part of the gate or operator All rollers should be covered to prevent injury KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate hardware The entrance is for vehicles only Pedestrians must use separate entrance Test the gate operato
13. r monthly The gate MUST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death SAVE THESE INSTRUCTIONS APPLICATIONS The Apollo Model 7300ETL Slide Gate Operator is designed to handle a slide gate up to 32 feet in total length 30 foot gate with 3 foot tail and 1 000 Ibs A professional fence or gate dealer is recommended to assure proper installation Apollo Gate Operators are available only through qualified dealers with an outstanding reputation in the fence and gate industry These dealers will be able to recommend the proper equipment for particular applications Apollo Gate Operators are 12 Volt DC Direct Current powered A 12 Volt sealed battery 33 ampere hour minimum is recommended There are several advantages with 12 Volt DC systems e Low voltage virtually eliminates risk of electrical shock e Battery powered operators provide up to 200 operations in the event of power outages e The battery may be recharged with a trickle charger or by solar energy Electrical battery chargers should have a class 2 transformer rating If a trickle charger is used and a standard electrical outlet is not readily available a licensed electrician will be required for proper electrical hook up The following table should be used as a
14. rs Hard Shutdown mode of software UL When grounded opens gate and holds gate open until released Clears Hard Shutdown mode of software IET EII II SY III IO IO GND Supplied Battery Ground INP Activate Gate Push button activation when momentarily shorted to ground 12V Supplied Battery Voltage Protected with 3 Amp fuse 21 A P O LLO Gate Operators Inc 911 Siren The 911 Siren is included with all Apollo ETL Gate Operators Mount siren in an area that will produce maximum performance additional wire may be required Connect the red wire to the SIREN connector on the Remote Monitor Output Connector block Connect the black wire to the GND connector on the Remote Monitor Output Connector block ay GND MAS WD SIREN oH LOCK Set Program Switch 4 as preferred ON Upon activation Siren will start for 5 seconds before gate s begin moving OFF Siren and gate s start immediately upon activation Iwi TIMER TO CLOSE Mu TIMER TO CLOSE OPT SLAVE DISABLE SIREN DELAY STOP CIRCUIT ENABLE LOCK TYPE COAST ENABLE FREE EXIT OPT SMART ACT Fl ort oe PEER RReEaE APOLLO cate operators RECEIVER OPTIONS Do not confuse the receiver code switches with the red program switches on the gate control board Never set all code switches to the same position Transmitters must match code switches for proper operation If power is taken directly from batt
15. th limit switches Yellow Feedback from intelligent actuator 816E 816EX Black Battery Negative Red Battery Positive EMERGENCY BYPASS open only Applies battery voltage directly to motor to open gate if control board fails User must unplug before gate opens to maximum travel or 15 amp fuse will open Fuse should be checked before returning gate to service Remote Outputs and Photo Eye Hookup Supplied battery voltage Master Operator Indicator indicates master side of gate is closed 12V when on closed limit Ground when off of closed limit Slave Operator Indicator indicates slave side of gate is closed 12V when on closed limit Ground when off of closed limit Battery supplied ground Connect to siren applies 12V when gate s are running or in hard shutdown uc f f q Battery supplied ground Connect to lock optional Magnetic or Solenoid type locks Dip Switch Z6 Selectable Photo Eye Hookup Photo eye safety loop wiring Connect the positive power wire of the accessory to 12V Connect the ground wire of the accessory to MAS upper right area of the 835 836 board Connect the relay wires of the accessory as normal COM to GND NO to SAFETY 714 for a safety device When the gate operator begins opening comes off of the closed limits the MAS terminal will become a ground and will complete the flow of power to the accessory This will power the accessory up and it will work as normal until the
16. uts 835 8 4 amp 5 GND Supplied Battery Ground INP Activate Gate Push button activation when momentarily shorted to ground Ll 12V Supplied Battery Voltage Protected with 3 Amp fuse e a GAD GND Supplied Battery Ground NP Activate Gate Push button activation when momentarily shorted to ground 2V Supplied Battery Voltage Protected with 3 Amp fuse EDGE Reverse edge input When grounded will stop and reverse gate if closing resets close timer if gate is open EDGE Reverse edge input When grounded will stop and reverse gate if closing resets close timer if gate is open GND Supplied Battery Ground GND Supplied Battery Ground STOP Stop input from a 3 button station must remove STOP CIRCUIT JUMPER Normally closed CLOSE Close input from a 3 button station see program switch 5 for options OPEN Open input from a 3 button station see program switch 5 for options GND Supplied Battery Ground GND Supplied Battery Ground FREE EXIT Opens gate if closed stops and reverses gate if closing resets close timer if gate is open GND Supplied Battery Ground SHADOW Resets close timer when gate is open also referred to as under gate loop RU GND Supplied Battery Ground an 14 yg L SAFETY Resets close timer if gate is open stops and reverses if gate is closing Does not open a closed gate GND Supplied Battery Ground FIRE When grounded opens gate and holds gate open until released Clea