        2N Helios User Manual
         Contents
1.                     s                 ew                x1       DTMF into outgoing call           Hy    z  Off hook by key 6  into telephone mode               Pea 6   fel ds  3    Telephone                            Hang up by key        Hang up by key 9    Explanatory notes   v    Yes  always        Yes if this function is programmed    1  This holds if DTMF is disabled during outgoing calls  the corresponding tone is  transmitted in that case      2  If pulse dialling is selected  it is possible to switch into tone dialling by pressing   but not vice versa       17    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    6  Installation Instructions  6 1  Start Up    Please check the contents of your delivery   This manual 1 pc    Inbus key 2 5    Dowels  Screws  Substitute name plate 1 pc    Note  If you have bought a complete  packet   the delivery may contain additional items  including instructions for use and lists of available parts           6 2  Mechanical Mounting    Indoor wall  mounting    ZENTRY Helios  Indoor 1 module flush mounting box with  flush frame  Part No  9135351E  or  mounting 2 module flush mounting box with  frame  Part No  9135352E    2ENTHRY Helios    Outdoor   1 module wall mounting roof   wall IE Part No  9135331E  or   mounting T 2 module wall mounting roof  DE Part No  9135332E    ZENTRY Helios  Outdoor      1 module flush mounting box with roof  flush     Part No  9135361    or  mounting  i 2 module 
2.            5       TELEKOMUNIKACE       ZENTRY Helios  Door Entry System    User and Service Manual    Version 2 1    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Dear customer     We congratulate you on having purchased the 2ENTRY Helios door  communicator  which is the successor to the popular product 2N    EntryCom  We hope  you will fully enjoy using this new product for a long time to come     Merits of the Product    Exclusive design      high grade stainless steel finish    Slim line design     no cutting into a supporting wall is required   Exclusive long life white illumination     LEDs    New waterproof design    Buttons have no mechanical parts     long service life    Up to 16 buttons per unit    Optional equipment     camera  display  etc    Increased protection through Vandal Resistant panel    Electronic volume and Handsfree control     no need to open the cover   10  Ringing tone detection     hangs up automatically after a defined amount of rings   11  Voice menu based programming          CU DNO    a    List of Manual Product Changes    Version   Changes  A new version of the communicator firmware released in April 2007   Marking  FW 07 02 22  e New voice functions     new parameters 974  976 and 977  e  Double tone detection    e New implicit value of parameter 951       e Antivandal assortment upgraded    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    t FEATURES
3.      Helios programming mode accessible from by dialling into the  intercom only     Code lock     mode for entering the password for switch 1 or 2 activation using a  numerical keypad     Telephone mode     you can make a call  dial a number and hang up using the  numerical keypad     DTMF transmission during call     for outgoing calls only  numbers are tone dialled by  a numerical keypad button     Button substitution     the numerical keypad can be used instead of a number pre   stored under a button memory     10    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    5  Function Description  5 1  From External User s View  Visitor     Like normal Doorbells  Helios buttons are provided with labels the visitor finds the  appropriate button  e g  Mr  Smith  and presses it this activates Helios to then dial the  number pre programmed for under that button  the visitor can then hear the ringing tone  from the loudspeaker and the required  Mr  Smith s in this case  telephone is ringing  If  the Helios unit is connected to a telephone system you may be able to tag the port that  Helios is connected to so that you can see on the ringing phone that it is the Helios that  is calling  When the called party answers the call  the visitor and tenant can speak to  each other and If an electric lock is connected to Helios  the called person can open the  door by entering the correct password on the telephone keypad to activate the door or  barri
4.    2         Overvoltage protection     between        1000 V 8   20 us  conductors    12 2  Other Parameters    Backlight     current up to 1    consumption       Operational temperature  20 to   60   C           Coverage     IP         Dimensions  1 module   210  100  29 mm  h x w x mE  Weight up to 500          41    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    
5.   3 1  Basic and Extender Units           oO     Part No  9135130E Part No  9135130KE Part No  9135181E  Basic unit Basic unit Extender unit  3 buttons 3 buttons   keypad 8 buttons       Part No  9135160E Part No  9135160KE Part No  913582E  Basic unit Basic unit Extender unit  3X2 buttons 3x2 buttons   keypad 8x2 buttons       Part No  9135310E Part No  9135311E Part No  9135320E  Info panel Info panel     name plate Info panel   4 bell buttons  Replaces four name plates with one cover       independent product not connected to  A backlit buttonless panel used for the Enables the use of one half of the the telephone line  Combines four bell  telephone directory  house number  etc  extender unit for the telephone directory  buttons and space for the company or  opening hours  etc  department name  opening hours  etc     All the above mentioned units can be wall mounted without requiring any additional accessories   All the basic units can be complemented with a camera  proximity reader  see later  and display   under preparation   All units can be made more resistant using the Vandal resistant cover   Additional accessories  see later  are needed for outdoor flush mounting purposes        VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    3 2  Installation Accessories       Part No  9135331E Part No  9135351E Part No  9135361E    Wall mounting roof Flush mounting box Flush mounting box with 1 module roof  for 1 module with 1 module f
6.   iu E 4    1 1  OQPTIONAE AGOGESSORPIESZ   unu ua        D ashaku wakata                   4  2   PUHPOSBE    eoe                                                                           aoe  5  9                             uuu  thoi dite usa            une rape      ence atin eee                   6  3 1  BASIC ANDIEXTEPNDER UNITO   uuu           usun sayu Dis ui               Dua EN 6  3 2  INSTALLATION ACCESSORIES               un u usaba uuu      MC DEAD M QS Su eta DOR 7  3 3  INCREASED PROTECTION ACCESSORIES  sccacceccceccecececceceeseceeaenseaenseaenseaenecsenensesunseaenseaenscasnscecasnacass 8  3 4  GSM AD VOIP CONNECTION ACCESSORIES    cccccecececcececscecesecsesensesenecaenscdeseusessusesenseaenseenscaeseceass 8  3 5        uu nu nta saa este nee asso         8  3 6            COE S SOS u                                                      shuyuy                      UA uns       9      ELEC TAIC WOCKS                                            an         ing               9  3 8  CIBHEHACCESSORIES u gt                      es ae                         EE So            RE ED EE         9  A  TEHMINOLOQGY tbi            UIS E SER usis PI sS s        uz TE 10  5  FUNCTION DESCRIPTION                                                                   11  5 7  FROM EXTERNAL USER S VIEW  VISITOR                                                                  a           11  5 2  FUNCTION DESCRIPTION     NUMERICAL KEYPAD UNITS                                    a   
7.   ratio  For the description of the functions from the user s view see below     11    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    5 3  From Internal User s View  Survey of Functions     e Calling to Helios  You call the appropriate extension and Helios makes the call and gives a confirmation    tone after two rings  or as pre programmed   Now you can speak and control the 2  switches  program Helios  see later   and listen to what is going on outside and speak  to the calling party if desired      e Opening door  Helios contains a switch to which an electric lock can be connected  not included in  this pack   This switch can be telephone keypad controlled using a  digital  password  in two ways as shown in the default password 00 example below     or    The switch activation time can be programmed once the switch is enabled this  will also automatically terminate the call in the next 30 seconds        Notes    e Ifthe Automatic Multiple Number Dialling with Confirmation or the Silent Automatic  Multiple Number Dialling with Confirmation mode is selected and the password  starts with digits 1 to 5  an asterisk must always be used    e You Must enter every digit in the password within five seconds  or as pre   programmed  to avoid Helios from hanging up     e Switch 2 activation  light  e g     The second switch  if an additional switch is installed  can be controlled in the same  Way     e Switch 2 synchronisation   owitch 2 c
8.  Dialling without Confirmation  the ringing tone is recognised  and ends before the preset count of periods is exhausted  the call is regarded as successful     Maximum timeout for      pressing the next digit During password entering  etc        34    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299      Parameter   Parameter Name  Range  Defaut  Note    Possibility to hang up    963 by pressing the same 2 ue  button   yes  Possibility to dial the  next number by 0   no   964 pressing another 1   yes 1  button    up by pressing   1   1   DTMF  pus   Le ue o       repetitions between every two messages    digits communicator identification   number  language selection  for a message      J 1   English    about a call 2   Czech     3   Slovak  termination 4   German 5   Russian  language selection  977 for a message of   calling     99   Service password     12345  12345 by defaut      Deletion of  switches Service     og  Clearing ofall         WE Clears memories 01 to 55  memories 01 Clears memories 01 to 55  55               5         Full initialisation mum Clears memories 01 to 55       6 Polish 7   Slovenian  8   Portuguese          Warning  Changes the service password too  setting the default value of  12345       Types 3 and 4      Dialling without Confirmation differ from each other in how they process very  short calls     few seconds   Dialling type 4 regards a call as successful in all cases  type 3 only if the door  Was o
9.  Helios can play  back a message stored in its memory  The test series includes the  Wait please   connection is being established  message  Later  more messages will be available to  the user    DTMF Control    If Automatic Multiple Number Dialling with Confirmation or Silent Automatic  Multiple Number Dialling is enabled  Helios can be controlled as shown in the table  below  For convenience  commands 1 to 5 are arranged as they are usually used     DTMF    CHARACTER FUNCTION    Confirmation indicating to Helios that a call was successful   Helios sends its confirmation signal  the call goes on until the end  of timeout and any of the following commands can be used     Message muting  during playback    WARNING  You may not speak while Helios is playing back the    message      Message re plays  once      4            extension           is extended      30 seconds      this      command         be used repeatedly   Or Call termination           9  oe are interpreted as a password beginning   for switch    Notes    e These commands do not work in the Automatic Multiple Number Dialling mode  without Confirmation    e        above mentioned commands may not be accepted due to poor connection if  sent during a message  To avoid this  press the button during the time of silence   between messages         39    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    11 2  Arrival Departure  Day Night Modes    Helios can identify easily where
10.  beeps refusal  refer to  Signalling  and hangs up immediately    e What happens if a password is identical with the memory number while the  code lock and button substituting functions are enabled  The code lock  function has the highest priority  If  for example  the password is 33 and you press   3  3     the switch is activated instantaneously  If you press without an asterisk   the line is seized after a preset delay and the number from memory 33 is dialled     Password Selection Tips    Tip 1  Keyboard letters facilitate password remembering  For example  it is easier to  remember a 9 letter word  e g  crocodile  than    9 digit number  276263453      Tip 2  It is not recommended to use such passwords as 3333  This leads to a  considerable wear and tear of one button and an unauthorised person may  guess your password easily  It is ideal to employ all keys evenly  using several  codes for different persons or groups     16    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    HELIOS Statuses and Available Operations                      Q                 Q  sS  Mee pressing     new call Y  x     Call extension   DTMF      v    Call termination   DTMF     V  v    Hang up upon continuous  busy or ringing  tone  x    Switch activation            password                      Programming start              gt       Y   Switch activation     code lock      x1                       O   E      O   s             O              O       
11.  however It  can also be connected to an analogue line or the GSM interface providing a wireless  Installation     Connection to Telephone Line   Connect Helios simply using LINE terminals  The advantage is that the Helios  requires no power supply because all power is fed from the telephone line     except for  the button backlight and electric lock  if connected  Nevertheless  Helios can work  without these circuits too and sends an acoustic signal on having been connected to a  line  or after having been disconnected from the line for a defined period of time      Printed Circuit Board  PCB  Description    Explanatory notes to the figure     1  Terminal board 11  Extension unit connector  2  Left button connector 12  Series number  3  Display connector 13  Main microprocessor  4  Voice memory 14  Configuration jumper block  5  One chip Handsfree telephone 15  Right connector  6  Switch 2 connector 16  Jumpers  7  Keypad backlight connector 17  Camera connector  8  Connector for non standard functions 18  Camera setting jumpers  9  Microphone connector 19  Loudspeaker connector and panel  10  Keypad connector grounding  21    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299                GND i   ui      9135160  9135160     sl TENTIA    91355130  9155150K  viDEO  h                      22    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Description of Terminals    GND    This terminal
12.  infrared light  built TV set  The right to change the I I      n obe used to watch the video   Quality   data  Horizontal vertical tilting option  design is reserved     flow control option  Free SW for intelligent  recording of the video record into a PC   includes movement detection      3 7  Electric Locks       Part No  932080E Part No  932090E  Part No  932070E art No  932080 art No  932090  BEFO 1221 BEFO 1211MB  BEFO 1211 12V   600 mA I          with torque        with mechanical blocking    3 8  Other Accessories       Part No  9135250E Part No  91341481E Part No  5 34148    Additional switch 12V   2A adapter SIEMENS   adapter    A stabilised power supply must be used if  a camera is installed  It can also feed the  lock and backlight     Switching and breaking contact option   time unlimited switching  up to 48 V   2A     This is required when connecting to a  Siemens HiPath Telephone system       Part No  932928E Part No  9135301E Part No  9135302E  12V Transformer name plate double button name plate  9    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    4  Terminology   Line pick up seizure off hook   call start  line locked  busy    Line hang up clear   call end  handset hang up    DTMF     dual tone multi frequency signalling    PSTN   public switched telephone network    Outgoing call     Helios telephone connection made  e g  by a pressing a button   Incoming call     telephone Helios connection     Programming mode
13.  is entered  Helios  repeats the parameter  or memory  number and reads the current contents  excluding  passwords   Now you can enter new data   of variable meaning and length depending  on the function selected  refer to the Programming Chart   Finally  press  amp  again for  confirmation  Helios confirms the data saving  Repeat this procedure for each  parameter     Programming Error   e Any wrong value can be re programmed by another command  immediately or any  time later     e  f you make a typing error  cancel the entered value with J  Then you can re enter  the whole number    e  f you enter an incorrect function number or parameter value  Helios sends a refusal  signal and you have to start with the function number again    e  f you do not press any button within a predefined timeout  Helios sends a hang up  signal and hangs up  The timeout is 5 seconds  every  amp  character is followed by 30  seconds for you to think over your setting  The 5 second limit starts when Helios    31    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    has read all that relates to the current user position in the programming menu  The  timeout can be prolonged     see the chart     Switch Password Programming   Each switch can be controlled with up to 10 different passwords that are listed in the  Helios memory  Passwords can be added to the list using functions 811 and 821 and  deleted with functions 812 and 822 individually  The default stat
14.  protects Helios against static electricity damage     SW1   Switch 1 designed primarily for electric doorlock control   NE        LIGHT      These two terminals are connected to the 12V power supply with  arbitrary polarity  The power supply can feed the electric lock too        These two terminals are connected to the analogue telephone line with            polarity          Video signal output     used only if a camera unit is included  The  coaxial cable is connected with an internal conductor to    with  shielding to          Description of Jumpers       Connector  8     Here connect the current call indicator  LED     Write protection  if the jumper is mounted     do not connect   Microphone sensitivity reduction  mount the jumper for noisy  environments            Camera setting     connector  18   refer to the instructions enclosed to the camera unit     Parallel Connection   Parallel connection of multiple telephone sets was commonly used in the era in  which telephone lines were rare  It carries unnecessary risks to connect the unit in this  way  It is in no case recommended to connect Helios in parallel to another telephone or  another Helios door communicator  It is neither admissible to use equipment that  switches one line between two or more sets  intelligent double branch  etc       23    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    7 1  Common Instalation    Typical Electric Lock Connection   Helios contains a 
15.  reris anna 11  5 3  FROM INTERNAL USER S VIEW  SURVEY OF FUNCTIONS                                                                 12  5 4  SIGNALS OVERVIEW                               u padece Master onions                        13  55  MESSAGE OVERVIEW uyum                   ee           e          A aeei 13  5 6  CALL TERMINATION OPTIONS   SUMMARY                                      14  5 7  CODE                                                  14  5 8  TRADITIONAL BUTTON TELEPHONE    22 202                         14  5 9           TRANSMISSION DURING OUTGOING CALL                                                          15  510  BUTTONS  SUBSTITUTION  toot u y a detto Sa uyu SQ                                  15  5 11  KEYPAD OPERATION INSTRUCTIONS   SUMMARY                   a          15  6  INSTALLATION INSTRUCTIONS                  e nn n hh hh hh hh hh hh 18  6 1  GAB OUP NUMINI    IM TP RIE  APRS oR PRR    Sas  IDEA UM asss 18  6 2  MECHANICAL IMOUNTING y uuu u u l uuu nasa         Garside de LM RU DM Sua ua usai 18  6 3  BUTTONS LABELS     INSERTION  REPLACEMENT                                    a  a         20  7  ELECTRICAL INSTALLATION                                                              21  7 1  COMMON INSTALLATION    yuyu uu mom a                                             i E E Er UDINE          24  7 2  CAMERA INO TA AT ON uuu uuu i          G uuu u au damu h i         UE apas m 27  7 3  DISPLAY INSTALLATION           Maia            v tatu 
16.  the  backlight   or just that two weaker power supplies are available    Supply  AC or DC  max 48V    Supply  AC or DC  max 12V     WM   37272 2 9        tel   line    6020103 63                    E Ium  3  zz JO            a ee ante vt ra   3                                 MENIMO    EN  06 0776 0014            tva 073            26    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Connection of Switch 2    A new additional switch  Part No  9135250E  has been designed for Helios  It  can be mounted into any basic unit  as an added option  To connect it  follow the  Instructions included in the switch delivery     7 2  Camera Installation    The camera unit  Part No  9135210E  can be built into any Helios basic unit  during installation or as an option to be added later  You can also use the camera unit in  combination with any Vandal resistant panel  It is a colour CCD camera with high  resolution of 420 TV rows  with a monochrome night mode  infrared backlight hidden  under the nameplates   and has a wide angle pin hole lens  90  diagonally  and a tilting  hinge for manual direction adjustment    The camera has a PAL composite output and can be connected to any TV  display  e g  Part No  9134147E   7  TFT LCD   or a video server  Part No  9134145E   MPEGA LAN video server   A coaxial or twisted cable can be used for connection    A sight glass is included in the delivery  which replaces the non transparent  Helios basic unit 
17.  the  person  at the other end  who activated the switch  signals that a non programmed button has been pressed   signals that an incorrect password has been entered on the  My keypad         Refusal can be heard from the loudspeaker after line connection  first  connection signalling    signals an incoming call if Helios has not been programmed   e When a disabled function has been entered from the keypad     JJ4   Storing  e Signals switch deactivation  if activated by                       Hang up  e Sent to notify that the call is terminated  in all cases      e Signals that the unit is going through full initialisation or dialling  Long continuous memory or password clearing   tone e Heard from the loudspeaker while the switch is activated by  keypad      Attention  your call  signals that the preset maximum call time will elapse within 10  is being terminated    seconds during outgoing and incoming calls   Wait  please  e Optional message during call establishing     Communicator    e Optional message for communicator identification  is calling     In the programming mode     5 5  Message overview     a er             Message about    call  value   order     Czech    rub Message about a call establishing    termination  976 977 version    0   original signal Switched off         Attention  your call is   Communicator number i  1       Wait  please I  being terminated    Slovak    Polish  7       Initial value  ATTENTION     Czech version of the product has Czech languag
18.  the preceding one   Every unit has two connectors     one  input  for connection towards the Helios basic unit  and one output  for connection of  another  remote unit   For proper function and sequence of the buttons keep the right  orientation of the units and do not interchange these connectors     This connector is intended for the  next extension module connection                 Maximum Count of Extender Units    panno onsems  e    4                      mmf    This table shows that single button and double button units can be combined easily     28    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Cable Interconnection of Units    e Every extender unit delivery contains a connecting cable with identical ends  The  connection ratio is 1 1  It is impossible to insert the connectors incorrectly because  they are provided with a key    e The basic unit is always on the left  The extender units are    chained     each unit  being connected with its neighbour    e  he cable cannot be pulled through the frame connecting hole until the frames are  interconnected  refer to the Mounting section      This connector is intended for the  next extension module connection     Imortant warning     Extension modules must be interconnected by mounting jumper  tunnel    delivered together with each extension unit  This part is made from conductile  plastic  If it is necessary to place extenson unit at some distance  or if you lost   the jum
19.  to    route     switch  a call after a button is pressed  All  you have to do is call Helios and enter the following     I m leaving  password     back  password    All buttons can be switched all at once by a common Day Night password or  individually by separate Departure Arrival passwords     How does switching work    e Every button has memories for 6 numbers  intended primarily for Automatic Multiple  Number Dialling     e  fthe Automatic Multiple Number Dialling mode is OFF  memory 1 is used for the Day  mode and memory 3 for the Night mode  This is a simple two number switching    e lf the Automatic Multiple Number Dialling mode is ON  memories 1  2  3  4  5  6 are  used for the Day mode and memories 3  4  5  6 are used for the Night mode in the  above mentioned order  This accelerates the process  numbers that would not be  answered are skipped over     e  fthe Night mode is on and memories 3 to 6 are empty  memories 1 and 2 are used    e  f the Night mode is on  memories 1 and 2 are omitted for all buttons and this  cannot be disabled individually using the Arrival function    e  n the Day mode  the buttons assigned to persons who used the Departure function   are on a leave  shall remain in the Night mode until the same persons use the  Arrival function  after the leave  e g       Example 1     administration building  automatic dialling is off   Button 01  labelled Mr  Smith  memory 1   Mr  Smith s line  memory 3     secretary s  line  password for button 01 is 77
20. 7   1  Mr  Smith is leaving for holiday  He calls Helios and enters  077709169   2  A visitor comes  presses Mr  Smith s button     Helios calls the secretary   3  Mr  Smith comes back  He calls Helios and enters  27776090     Example 2     family house  Silent Automatic Multiple Number Dialling     Button 01  labelled The Johnsons  memory 1   living room  2   workshop  3          Johnson s mobile telephone  4   Mrs  Johnson s mobile telephone   Arrival Departure password for button 01 is 333     1  The family is leaving for holiday  They call Helios and enter  833309109     2  A visitor presses the Johnson s  button     Helios calls Mr  Johnson s mobile  phone and  if unsuccessful  Mrs  Johnson s mobile phone     3  Etc     40    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    12  Technical Parameters  12 1  Telephone Parameters    Parameter  Minimum required off hook line current Off hook  Minimum required on hook line voltage     20V       20V      DC voltage drop  off hook    av     25 mA     16V     50         Lead current while hang up    25 uA U   60 V    Off hook AC impedance 220 Q   820 Q 20 to 60 mA  115 nF parallel     10dB   20 to 60 mA  Bandwidth 300 to 3500 Hz   20 to 60 mA    Ringing impedance  gt  2      25 to 50       C 1 uF    Ringing detector sensitivity 10 to 20 V 29 to 50 Hz  Time of response to Tine ML ME   Variable   _  Pulse      Puledialing     40   60 ms 20 to 60 mA    DIMF level  6 and  8 dB 20 to 60 mA 
21. an also be used to delay the opening of another door  Once the switch 2    delay timeout is programmed  the second switch is synchronised automatically with  the first one  the delay being 1     25 seconds     e Switch activation signalling  for both switches     After the correct password is entered  the switch is activated and you can hear the  confirmation signal on your telephone  You can now speak  e g  say   The door is  open   or listen  to the door opening sound  etc   until the switch is deactivated   Upon deactivation  you can hear the storing signal  see the Signals Overview      e Call extension  Helios beeps 10 seconds before the call end to extend the call by 30 seconds press  on your telephone  DTMF   You can use this function repeatedly  The visitor   however  cannot use this function     e Programming   he access to this mode is password protected  For details refer to the    Programming section  The voice menu considerably helps with programming the  Helios unit  Having entered the programming mode  you can also alter any  parameter and memory settings     Caution  The above mentioned functions  except for calls to Helios  require a tone   dialling telephone set     12    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    5 4  Signals Overview    sent immediately after line seizure for incoming calls  can be  Confirm  heard by the calling party    ation  e signals switch activation  by                    be heard by
22. arameters are stored safely in the non volatile EEPROM memory  The memory  capacity does not limit the count or length of numbers  passwords  etc  This means that  altogether 324 memories for 16 digit telephone numbers  54 Arrival Departure password  memories  20 switch password memories  etc  are available     Tip   Before You Start Programming      Write or print the values to be programmed to minimise the risk of error  Moreover   this gives you an idea of what you have programmed  Make sure that programming  is not barred  JP1 jumper      refer to the PCB Description subsection     Entering Programming Mode   You can enter the programming mode only during an incoming call  telephone      Helios call   The programming barring jumper must not be mounted  To get into the  programming mode  enter the service password in the format      password      do not  forget to enter the asterisks before and behind the password    The service password is  12345 by default and can be changed    If you enter the password correctly  the voice  menu is launched  Now you can start programming     Programming Procedure  You can set parameters in any order and as many times as you wish  To change a  parameter use the following command     Function number  amp  parameter    A three digit function number is assigned to every parameter to be programmed  and to every memory  refer to the Programming Chart   This number indicates to Helios  which parameter to change  and is used as  Enter   When it
23. astructure behind  It  The connectivity of the unit is flexible in that as standard the unit can connect to any  telephone system via either an analogue extension or trunk port  The Helios unit can  also connect to any network provider s analogue telephone line    2ENTRY Helios is also easy to use     just press the desired call button and the  Helios unit will automatically  dial  the number pre stored in the respective memory   The number of buttons is flexible as it is a modular unit     ZENTRY Helios also has a switch that controls the electric lock by using any  telephones keypad  by tone dialling the password      In addition to the buttons  you can use a numerical keypad  which is used as a code  lock  Using the keypad  you can operate the device as a button telephone and dial the  required numbers directly or retrieve them from any of the 54 memories available  You  can disable non desired functions     ZENTRY Helios provides improved and feature rich options compared with standard  door entry systems  this is because you can make use of functions such as call  redirection if not answered  or have a day and night mode set up for automatic  redirection of the call for instance after normal working hours     The 2ENTHRY Helios parameters meet all technical requirements mandatory for  devices designed for the PSTN  public switched telephone network  connection     VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    3  Product Mix
24. e under number 1 and  English is under number 2           13    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    5 6  Call Termination Options   Summary    The busy or continuous tone    after the call end    The ringing tone    after a predefined count of rings    The subscriber    at the other end    pressed         The preset maximum call duration has elapsed    30 seconds after the switch use has elapsed    A Helios button was pressed during the call    The  amp  keypad button was pressed during the call  can be disabled      UP Eris SY          The communicator is able to detect a permanent tone  busy tone and ringing tone  even if the tone has two frequency components as in the UK  the U S A   the so called  BIT tone  and in Canada  This new function does not require setting of any parameter   One of the tone components must be of 440 Hz     5 7  Code Lock    The electronic lock connected to the Helios can not only be activated by the phone  but also directly from the door using the keypad  In this mode  the keypad behaves like  a standard code lock with the following features    e Both switches can be controlled  if 2 connected   Password length   1 to 16 digits    Up to 10 passwords per switch    owitch activation time   1 to 9 seconds    Acoustic switch activation signalling     continuous tone     The code lock uses the same passwords as the ones that have been defined for the  telephone based switch control  Remember tha
25. ed to cut into mounting surface  Water resistant      Hermetically sealed buttons  e Separate electronics from name plates  Telephone based programming  Detection of all standard tones  Stable line power feeding  High acoustic quality  Electronic volume and Handsfree control     no need to open cover    Special functions includes automatic dialling of multiple numbers  silent  dialling  departure arrival  day night mode  second switch delay    1 1  Optional Accessories     Vandal resistant panel   e New resistant metal cover for better protection against vandalism   e Flush mounting steel box included in the cover price    e Can be purchased and installed as an option    Additional  second  switch   e With switching and breaking contact  relay     e Time unlimited switch option    Camera unit   e Canbe installed into any basic unit  incl  Vandal Resistant     e High quality colour CCD    e Wide angle  adjustable direction    Proximity reader unit     can be installed into the basic unit as an option     Display module   e Can be installed into any basic unit as an option    e Graphic LCD  backlight with automatic brightness regulation   e Upto 1 000 characters including text and graphics     e PC configuration  USB interface     www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    2  Purpose    The 2ENTRY Helios door communicator replaces    traditional door entry system  which would traditionally have to have a whole cabled distribution infr
26. er  When the caller hangs up  Helios detects the PBX or analogue line tone and  hangs up too  Helios also hangs up when it  hears  the busy tone or if the call takes  more time than pre programmed to connect  You can pre program the amount of time  that you have to speak into the microphone however when you are reaching the  programmed time the unit gives a warning tone 10 seconds before hanging up so that  the called party can extend the call if required   Notes   e  f the visitor presses another button during the call  Helios hangs up for a few  seconds before dialling the new number   e  f a button is pressed that has no number stored within it Helios picks up the line   sends a refusal tone  refer to the Signals Overview  and hangs up   e  f the visitor presses the same button during the call  Helios may hang up  can be  programmed to stop this feature if required    e  he above mentioned rules are only applied if the Automatic Multiple Number  Dialling mode is OFF  For this special mode refer to the Automatic Multiple Number  Dialling section     5 2  Function Description     Numerical Keypad Units    The 2ENTRY    Helios basic units  Part Nos  9135130K and 9135160K  are  equipped with a numerical keypad  The keypad provides a number of functions     traditional code lock   features as if a normal telephone set   DTMF transmission during an outgoing call  substitution of up to 54 buttons    The keypad features a smart metal design and very favourable price to performance
27. flush mounting box with roof  P Part No  9135362E    ZENTRY Helios  Increased fy Vandal Resistant cover with a box  Protection f designed according to the set to be    mounted       18    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Explanatory Notes to the Table Above     For the purpose hereof  indoor environment means   e Interior space with low relative humidity  such as corridors  offices and other  environmentally controlled rooms   e Interior space where moisture condenses on walls but in no case flows down  the walls  such as verandas  storing rooms  industrial facilities   e Exterior space sheltered against rain and water flowing down the walls  such  as shelters  passageways     For the purpose hereof  outdoor environment means   Environment  where a product is exposed to rain and   or water flowing down the  walls  such as fences  external walls of buildings  etc     WARNING   The warranty does not cover failures and defects of the product arising as  a result of improper installation  in conflict with these instructions   In  addition  the manufacturer shall not be held liable for damage incurred    through misappropriation from rooms that are accessible after the attached  electric lock is activated  The product is not intended as an anti theft   entry  device on its own only in combination with a classic safety lock        Wall Mounting    1  Drill holes using the template   inserted in the manual  Use the wall  d
28. he required  count of cycles can be preset  1 to 9  if none of the stored numbers is answered  the  whole cycle is repeated starting with the first number again  for each button separately    You can program Automatic Multiple Number Dialling for selected buttons only   retaining the others in the default mode  the selection of one of three automatic dialling  modes is common     Automatic Multiple Number Dialling without Confirmation    This mode can be used in common cases to enable the visitor to get through  even if the called line is busy or the called subscriber is absent  Hence  the second  memory of the button may include the secretary s number  the third memory the porter s  lodge number  etc    This mode recognises the ringing tone and if the tone ends before the predefined  count of rings  Helios regards this as a successful connection  this solution is not fully  reliable because detection may be hindered by noise  etc    No message is played back in this mode     3     VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Evaluation of Situations in Speakerphone Automatic Dialling without Confirmation    Helios Action  Busy tone Hangs up in approximately 2 seconds and dials the  next number     Call or silence without previous Waits for the preset timeout  log in time   then hangs  ringing tone up and dials the next number       Hangs      in approximately 2 seconds and dials the  Continuous tone  at the PBX  e g    next nu
29. ht Power Supply   Helios features a high quality white LED name plate backlight  This backlight shows  low power requirements  long life and even illumination of all name plates  If a standard  12 V electric lock  see above  is connected to Helios  the backlight can be powered  using the lock power supply  Connect the power supply as shown in the figure  Just  make sure that the power supply  adapter transformer  is able to supply the required  current constantly and that it is cooled properly  do not wrap it in any thermally  insulating material  or use ill ventilating covers  etc     The required current depends on  the count of buttons and other elements in the set and can be determined for 12  V according to the following formula     Basic unit without keypad  Basic unit with keypad   200 mA    1 one side extender unit    1 two side extender unit   100 mA    Camera    130mA  Reader   150        Display   200 mA    The above mentioned currents are maximum values at 12V        Cable Arrangement inside the Cover    We recommend you to use a UTP cable  8 wire  approx  5 5 mm output diameter  for  Helios connection  Push the cable into the groove on the left side of the cover  If you  combine this cable with another one  e g  the electric lock 2 wire cable   insert the 2   wire first and then the UTP cable to prevent the 2 wire cable from falling out  You can  also fit the cables with common clamp tape     WARNING  An improper cable arrangement may cause a malfunction of the  
30. igure    using  e g   a screw driver     3  Remove the name plate inserts as shown  in the figure     4  Insert the labels printed on foil  see later         5  Replace the name plate inserts    6  Put the name plates back in the depression and click into position  The name plates  keep the matt foil steady    7  Replace and screw on the metal cover     Note  You can remove the name plates even without removing the metal cover however damage  if any   incurred as result of this  is not covered by the warranty     20    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Label Material and Printing   Every Helios delivery includes a sheet of transparent foil that can be easily  printed  with a laser printer  Cut the printed foil into pieces and insert the labels into the  name plates  Do not use paper to avoid water logging    Make sure that the text does not cover up the red arrows printed on the name  plate  we recommend you to print the foil using a template  MS Word   available at       WWW 2n CZ     Single surface button Horizontally split button               01              04         Name 02  Name 02 pampama   Name 03  Name 03 Name 06    7  Electrical Installation    Compalibility   Helios is designed for conventional  analogue telephone lines and works regardless of  polarity and line parameters  Refer to the Technical Parameters  and uses tone  DTMF   or pulse dialling to be programmed  Normally  it is connected to a PBX line
31. ion   01   54     the number that complies with the selected button  memory  is dialled  after a timeout      f an asterisk is pressed after number 01   54  the number is dialled  immediately unless it is identical with the set password     15    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Frequently Asked Questions Reqarding Keypad Function    e Canany of the switches be activated permanently   Yes  the additional switch can be activated by one password and deactivated by  another     e Is it possible to arrange for the switch to be activated during the whole call   Yes  additional switch can do it     e  s it possible to use a single command to activate one switch first and the  other later   Yes  it is possible to use parameter 824  Switch 2 delay     e Can both the switches be activated at the same time   While one switch is activated  the other can be activated by another password  You  can also use parameter 824  Switch 2 delay  defining the shortest delay time  possible  1second  and a sufficiently long switch activation time     e Canluse the code lock while another person is speaking through Helios   Yes  but this is not advisable as you should be aware that the password is private and  could contravene security     e What happens when    press a number with no pre programmed memory while  the button replacing function is enabled  The same as if you pressed a button  that is not pre programmed  Helios seizes the line 
32. is  entered than is allowed by the  PBX ringing timeout      Max  call duration 12 120s              of 105 9905            ipiimemt   199      330 seconds   Hang up time 5 99 15   15s   between calls    921  Code lock mode 1   enabled   Buttons replaced 0   disabled  EM  0   disabled              923   Telephone mode 0   disabled   For details on these functions    Tone dialling see the Keypad Description     924   0  0   disabled  during call    Microphone 0   Maximum microphone  power up level sensitivity    lt   o speed      933  Reception volume   Reception volume   6  15   Maximum reception volume    Transmission  0 15 T 15   Maximum transmission volume            E volume 12   Maximum tone volume             hearing 0 3 3 3   Maximum DTMF volume   side tone  volume    Count of rings  911 before incoming 1 99 2  call answering       Loudspeaker  volume    Minimum conti  If the tone is longer  Helios  10   99  nuous tone time hangs up   period    i Th t trol th       fire sam                                Maximum           _ used for call termination and  9     space difference eem 10  0 15   automatic dialling     s  mapas   29   4  busy tone periods  space time   E between parameters 952 and  Count of ringing 1 99 10 If the preset count of periods is  periods I exceeded  the call is terminated     15   Maximum loudspeaker volume           If the preset count of periods is exceeded and automatic dialling is enabled  another attempt    follows  In the event of Automatic
33. mber     Ringing tone  which is terminated Regarded as a successful call  continues for the    before 10 rings are made  the count   maximum timeout  maximum call duration    of rings is variable  For details refer to the text under the table     Ringing one uy ee meee te Hangs up and dials the next number   count of rings is variable     If the ringing tone stops before the predefined count of rings is achieved and the call is thus very  short  e g  2 seconds   it is not clear whether the call should be regarded as successful   Therefore  a new type of automatic dialling has been added   type 4  The difference is as  follows    e Type 3 regards such a call as successful only if the door is opened    e Type 4 regards all such calls as successful        Automatic Multiple Number Dialling with Confirmation    This mode is used where maximum connection reliability is required     for  emergency calls  The called line  the supervisory control centre  e g   must be operated  by a well trained person to confirm connection  The DTMF is used as the most reliable    criteria for successful connection  The called line must press on its telephone  If the  called number is busy or remains unanswered until the preset timeout or in other cases   see the table   Helios dials the next number in the sequence     Evaluation of Situations in Speakerphone Automatic Dialling with Confirmation  Helios Action   Busy tone Hangs up in approximately 2 seconds and dials the  next number      Waits for 
34. med ones     5 10  Buttons Substitution    This function is an analogy to memories in comfortable telephone sets  After two  digits ranging between 01 and 54  0 may not be omitted  are pressed  the call to the  pre programmed number is made  You can use Helios as if it had up to 54 separate  buttons  which saves buying the extender units and space on the installations wall  The  ideal solution is to use a few standard buttons for the most important speed dialling  options e g  Warden  Reception and then provide a list of pre programmed options via  the optional info panel that can be purchased     Admissible Keypad Function Combinations  All of the above mentioned 4 functions can be combined freely     each of them can be  enabled or disabled separately as desired     5 11  Keypad Operation Instructions   Summary    e Door opening   code lock  Enter any valid password for switch 1 andl    Warning  Password 00 may not be used     e Switch 2 activation   Enter any valid password for switch 2 and B9    Warning  Password 11 may not be used     e Traditional button telephone  gets Helios ready to dial a number    0      9  Dials a number   Transmits into tone dialling during pulse dialling   Transmits a character in tone dialling   Hangs up anytime during a call     e DTMF transmission during outgoing call    of a single button  not in the telephone mode     0     9    tone dials a number     The character is sent normally     The character is sent normally     e Buttons substitut
35. or both switches including passwords 00 and 11   998   deletes memories of all buttons  01   54  plus Arrival Departure and Day Night  passwords   999   clears the whole memory and resets the default values  see the chart      Protection against Unintentional Deletion    The above functions need no special parameter but must be protected against  unintentional initiation  Therefore  enter the service password as the function parameter   Warning  Full initialisation takes a few seconds  Helios sends a continuous tone while  memory clearing  Functions 997 and 998 take a little less time and are signalled by a  continuous tone too     The button memories can be deleted individually too     just enter a  blank  while  programming  For example  clears memory 1 of button 01     32    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    9  Full Parameter Chart      Parameter   Parameter Name  Range  Default  Note  All button Up to X X x B9 NUMBER  memories 16 blank Memory number  1   6    digits Button number  01   54  Digits 0 9 can only be entered directly into the memories  Special characters are entered additionally using function XX 7     Entering format  XX7  XX xx B9  Enter special Button number  01     54    chars 1    XJ 2       3   space    XJ and space   Button memory number  1   6  Character position  01   16    Note  The digits behind this position are shifted automatically     Count of X X 8   X   automatic dialling 0   off Coun
36. owels attached    2  With multiple module sets  connect the  frames as shown in the figure  Place  the basic unit on the left and extender  units on the right  The interconnecting  cable should be installed later    3  Put the blanking modules on the  unused side holes as shown in the  figure    4   f you are utilising a roof module  you    should install it now    5  Screw Helios onto the wall  Carry the supply      cables  line  lock  power supply  through one of    the holes into the basic unit frame    6  If you use a roof module  fix its upper and side  edges to the wall using silicone as shown in the  figure           19    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Keep the following outdoor mounting principles   e Connect the button backlight for equipment heating     refer to Electrical Installation     e Fill the roof and the fill the gap with waterproof cement to prevent water from  getting into the box  see Fig       e Water must not flow in along or around the cables   Flush Mounting    Use the installation instructions included in the flush mounting box delivery     Anti Vandal Mounting    Use the installation instructions included in the Anti Vandal mask delivery     6 3  Buttons Labels   Insertion  Replacement  Instructions    1  Remove the Helios metal cover  To do this  use  a hexagonal key  unscrew the screw as shown in  the figure and take the cover off           2  Remove the name plates as shown in the f
37. pened    2  New implicit value     smaller possibility of an unintentional detection  3  Czech version has language order  1   Czech  2   English    If You Forget the Service Password  If you forget the service password  contact the manufacturer  The manufacturer can  change your service password to 12345 remotely without altering any other parameter     Second Switch Synchronisation      1 3  Explanation Suen mmm      623   The numbers in the figure                parameter numbers   SWITCH 2         mi        824     The parameters can be set to overlap 813   activation of the two switches  SWITCH 1     W   ig 923    HAM                        35    824     VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Account of parameters 941  942  943  944    Busy tone    Period    Parameter 942       Space Parameter 943       Example   Tone     space difference is 500     250   250 ms     Set parameter 944 to 300 ms     Note     Increase parameter 944 also when H  lios is placed in the hall or corridor with a large  decay time     Account of parameters 951  952  953       Ringing tone  example   At this time Helios detects   that ringing tone had ended     Ringing tone                Param  953       Param  953    36    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    10  Maintenance  Cleaning    If used frequently  Helios  especially the keypad  gets dirty  To clean it  use a piece of  soft clo
38. per  you must interconnect metallic covers by another way        29    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Button Numberinq    Button numbering     single button sets    is   mo       Numbering   eme    m qm o     unit has a  keypad                      To be continued to 54    Button numbering     double button sets    numbering   plan if the   unit has a  keypad        Caution  The Vandal Resistant panels are only available as single button sets and one  extender unit maximum     Button numbering     infopanel sets   The numbering plan will not change when you install the infopanel name plate     Part No  9135311E  into an extender unit however 8 numbers will be omitted when you  install the infopanel  Part No  9135310E     30    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    8  Programming    All Helios parameters  including the keypad ones  are set remotely using any tone   dialling telephone set  or a mobile phone   First call Helios and enter the programming  mode  The access to this mode is service password protected    A voice menu is available in the programming mode and so you need not use this  manual to program standard parameters  The menu is stored in the Helios memory in  the default language  Having entered the full parameter or memory number  you can  hear how the parameter has been programmed  thus checking the programmed  numbers for correctness    All p
39. rame Roof dimensions  WxHxD     Dimensions  WxHxD   Dimensions  129 x 240 x 41 mm  103 x 218 x 60 mm 125 x 235 x 46 mm Hole  WxHxD    Hole  110 x 220 x 50mm    5mm    110 x 220 x 50   5 mm            Part No  9135332E Part No  9135352E Part No  9135362E  Wall mounting roof Flush mounting box Flush mounting box with 2 module roof  for 2 modules with 2 module frame Roof dimensions  WxHxD     Dimensions  WxHxD   Dimensions  229 x 240 x 41 mm  203 x 218 x 60 mm 225 x 235 x 46 mm Hole  WxHxD    Hole  210 x 220 x 50mm    5        210 x 220 x 50   5 mm    All mounting accessories are made from stainless steel particularly necessary for  outdoor applications unless there is suitable weather protection  The flush mounting  frame box  without roof  enables installation of the Helios unit indoors so that it does  not protrude from the wall  up to 1 mm      VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    3 3  Increased Protection Accessories       Part No  9135511E Part No  9135511KE Part No  9135515E           Vandal resistant cover for Vandal resistant cover for one  Vandal resistant cover for basic    it with k Flush    it   Flush  unit   Flush mounting box    basic unit witt eypad   Flus extension unit   Flus  mounting box    mounting box          Attention  This box is not 9135351E     It is a special box only for Vandal resistant covers     The purpose of the covers shown above is to make the basic units or sets with up to 11  buttons a
40. roduct  Before closing the cover  check all wires and the cover for perfect    closing              25    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Grounding Terminal Connection   Mandatory    Any person that gets in contact with Helios may carry an electrostatic charge of  several thousands of Volts  Drawing one s finger near to the Helios metal panel may  result in spark discharge  The purpose of the grounding terminal is to protect the  product against this discharge  The terminal carries the charge from the panel to the  ground directly  not through the Helios circuits    Where no grounding cable is available  it is possible to connect the grounding  terminal with any of the telephone line terminals    In some telephone systems one line  terminal is directly connected with the ground  the others carry current to the ground  through overvoltage protection        Note  This connection eliminates direct connection of the line conductor onto the  panel because there is a protective element between the panel and the grounding  terminal     Separate Button Backlight and Electric Lock Feedin       oeparate power supplies are necessary where the lock requires voltage higher than 12  V  In this case  an additional power supply  12V  must be used to illuminate the button  backlight   see the figure below  Other reasons for such connection are the effort to  minimise consumption from the back up supply  which supplies the lock  not
41. s weather and vandal resistant as possible  More extensive sets can be tailor   made  Remember that the Vandal resistant set must always be flush mounted and  needs no roof even if used outdoors     3 4  GSM ad VOIP connection accessories            GSM gateway Easygate  Analog VoIP gateway   501303E Part No  9134171E    3 5  Display    Black  amp  white  Graphic LCD 128 x 64 pixels   white backlight  up to 1000 characters   configurable via USB interface  can be  installed into any basic unit as an option     Part No  9135240       VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    3 6  Video Accessories     gt             pu  m  1  T7   T       Part No  9135210E Part No  9134147E Part No  9134145E  In built colour CCD camera 7  colour LCD monitor          MPEGA LAN video server    Video records can be observed by  anybodies PC via the LAN  no SW  installation is needed  Serves up to 10 PCs    PAL  resolution 420 TV rows  sensitivity 2 lux The selected model features a       I So   I      at the same time  The          4  The camera can be built in any basic unit  In composite video signal input with high       I i I      compression ensures the network load is  the case of poor light  the camera switches sensitivity for long cabling runs  Vivid I      I I U e approximately 10 times lower than  into the monochrome mode automatically  colours  wide angle display option  in   i U   uncompressed  The Internet can also be  Supplementary
42. sight glass imitation  To install the camera  follow the instructions that  come with it     IMPORTANT     To install the camera  use the stabilised 12 V dc power supply  To get a suitable  12V    2A  one  order Part No  91841481E     7 3  Display Installation    The display module  Part No  9135240E  can be built into any Helios basic unit   excepting units with vandal resistant panel  during installation or as an option to be  added later  It is black  amp  white  graphic LCD with resolution 128 x 64 pixels  white  backlight and USB interface for configuration    It has memory for up to 1000 characters  and it is controlled by basic module  buttons and keypad  if present  Each character can be alphanumeric or graphic up to  whole display size    A sight glass is included in the delivery  which replaces three button labels on  Helios basic unit  To install the display  follow the instructions that come with it     IMPORTANT     To install the disply  use the stabilised 12 V dc power supply  To get a suitable  12V    2A  one  order Part No  91841481E     27    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    7 4  Connection of Extender Units   The easy installation of the button extender units is one of the great advantages of  using the Helios system  The installation could not be easier   the units are connected  using one cable  included in every extender delivery  in a chain manner  every element  in the chain is connected with
43. solid state switch equipped with V MOS transistors  which is able  to switch both ac and dc regardless of polarity  Make sure that the current and voltage  values do not exceed limits  refer to the Technical Data  and that the technical  parameters of the lock and power supply are compatible                                      7 NEM                 n 2 255 779 Petes            TEILE ULL UM 1e  06 0776 0014 Fe 88 M    ren e                  Never switch 230      120 V mains voltaqe directly      If you do not have an electric lock and want to have one  you should select a 12  V lock  this being the most common type  Connect the lock according to the figure   which shows the button backlight supply too  see later     Dc supplied lock  Practically all locks can be dc and ac supplied  The ac supply is  more advantageous because the lock buzzes  which is the clearest signalling method  however to use a dc supply lock  from batteries  e g    you are recommended to equip  Helios with acoustic signalling  continuous tone during the whole switch activation  time      Caution  If the lock power supply fails and the telephone system carries on working  the  keypad equipped Helios system is unaware of the failure the switch will be password   activated and the activation is acoustically signalled  but the electric lock will not work  because of the lack of power     24    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Typical Button Backlig
44. t of cycles  0   9   cycles Button number  01   54   Arrival Departure  up to 16 blank X X 9 PASSWORD eS   password digits a POE CIGIS  Button number  01   54    Day Night up to 16 blat  The same as for Arrival   password digits Departure  identical for all buttons        Enter up to 10 Passwords 00 and 11  switch 1 cannot be entered from the  passwords up to 16 keypad    digits                    Enter up to 10 Up to 10 switch passwords    switch 2 Delete passwords using    017   to   547   018   to   548   019   to   549        passwords  Delete valid switch  1 passwords  Delete valid switch  2 passwords  time                functions 812  822    Deletes individual valid switch   1 passwords    Deletes individual valid switch  2 passwords        O   switch disabled  Switch 2 closing 0   switch disabled  time      0   switch 2 is not  Dialling type 1 pulse 40 60          599   8 085  Range of 0 5   9 95  after pick up  DTMF level   0302   6  J tstep  1dB    1   loud with confirmation   2   silent with confirmation   3   SP without confirmation     4   SP without confirmation 1     Automatic Multiple 0   disabled  Number Dialling for all    type buttons  The called party recognises   Ticking into call 0 12 0   off better that the incoming call is  from Helios     33       VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299      Parameter   Parameter Name  Range  Default  Note    Warning    No connection is  established if a higher value 
45. t the default passwords  00 for switch 1  and 11 for switch 2  cannot be entered from the numerical keypad because they are  notoriously known     Control   Enter the correct password            If the password is valid  a long tone is  transmitted for a predefined time  5seconds by default   The corresponding switch is  activated during this time  If the password is invalid  Helios sends a refusal signal     5 8  Traditional Button Telephone  Any number can be    dialled    in this mode  To dial  press  and to hang up usel     These keys are typically provided with pictograms and          PSTN calls can be  barred for a line in the PBX  The dialling type  tone  pulse  is selected in the  programming mode  With pulse dialling  the character initiates  upon off hook   transition to tone dialling     like on any other telephone    Note  If this function is enabled  you can press    to hang up an outgoing call initiated  by pressing a separate button     14    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    5 9           Transmission during Outgoing Call    This function enables the unit to transmit DTMF tones when the connection with one  of the pre programmed numbers has been established  It is used in combination with  automatic information systems  voice mailboxes  etc   which ask the calling party to  select a service using tone dialling  This function  however  does not allow you to call  destinations other than the pre program
46. th moistened with clean water  We recommend you to obey the following  principles while cleaning    e Never use aggressive detergents  such as abrasives or strong disinfectants     e Clean the device in dry weather in order to make waste water evaporate quickly     Label Replacement  Programming Status Changes    For necessary steps refer to the preceding subsections  Keep the following for later changes   e this manual    e the completed programming form  including a copy     e unused transparent foil strips for button labels     Always use the proauct        the purpose it was aesigneo                        for  in compliance  herewith     The manufacturer reserves the right to modify the product in order to improve its qualities     ZENTRY Helios contains no environmentally harmful components  When the product s service  life is exhausted and you would like to dispose of it please do so in accordance with applicable  legal regulations        11  Section for Advanced Users    11 1  Automatic Multiple Number Dialling    When you press a Helios button  you may find out that the called line is busy or  the called party is absent  Helios is able to identify these situations and solve them by  Automatic Multiple Number Dialling if one of three automatic dialling modes is enabled   Up to 6 numbers can be stored for each button    The three automatic modes  see below  recognise the continuous  busy and  ringing tones  In all of these modes  automatic dialling can be disabled or t
47. the preset timeout  log in time   then   Call or silence  hangs up and dials the next number         quae Waits for the preset count of rings  then hangs up   gng and dials the next number   Continuous tone  at the PBX  Hangs up in approximately 2 seconds and dials the  e g   next number        plur un      ns       36    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    Note  lt is sometimes difficult to recognise the above described situations reliably due to  a poor quality of the PSTN connection  Excessive noise in the surroundings may also  have a negative impact  However  this may only decelerate automatic dialling  the busy  tone may not be recognised  e g    Even if Helios cannot identify the DTMF  the  connection is established  yet for a shorter time      Silent Automatic Multiple Number Dialling    This mode fully conceals the fact that a telephone call is made  When a button is  pressed  the loudspeaker is off and no PBX or dialling tone can be heard  The  loudspeaker is switched on when the called subscriber confirms connection  by  pressing J      its telephone   Thus  a potential thief cannot establish whether the called  person is in the building or not    Otherwise  the function is the same as with Automatic Multiple Number Dialling  with Confirmation     Messages    There are situations in which the calling person does not want to or cannot speak  for security reasons in the automatic dialling mode  In these cases 
48. tpe aun                      on      27  7 4  CONNECTION OF EXTENDER UNITS                  n         28  8  PROGRAMNMMNING        L 2 22 2              C                        31  9  FULL PARAMETER                                                                             33  10  MAINTENANGE ten tibia                      Ty u aj CR NEP EPI OT DIXIE 37  11  SECTION FOR ADVANCED                                                   hh 37  11 1  AUTOMATIC MULTIPLE NUMBER DIALLING uu sccccccccccccccccccecccecececenenenenenecececensnenenenensnenenensnansnsnsnsnecaes 37  11 2  ARRIVAL DEPARTURE  DAY NIGHT MODpES                                                               ERO Nose sor              40  12  TECHNICAL                     5                                                                                                                            41  12 1   TELEPHONE PARAMETERS                   I nu eund                                                                                      41  12 27                                cities edet bu                 S e DSG          41  3    VolPon www voipon co uk sales voipon co uk Tel   44  0 1245 808195 Fax   44  0 1245 808299    VolPon    Features  Operates on any analogue telephone line  Telephone controlled electronic lock switch  Exclusive white button backlight     white LEDs  Modularity     up to 54 buttons   keypad  Applicable as a standard telephone and code lock  keypad version   Flat design     installation no ne
49. us is a single password  in the list  namely 00 for switch 1 and 11 for switch 2  These two special passwords  cannot be entered from the Helios keypad  To cancel them  you have to remove them  from the list     or    Function 997 deletes the entire password list for both switches including the  passwords 00 and 11  Function 999 deletes the entire password list for both switches  too but recovers the passwords 00 and 11 and the service password 12345     Password Selection Restrictions   Controlling the switches by phone  you can enter the password without any starting  and terminating characters and the password length is not limited  Helios has to verify  after every character received whether the password is complete or not  Therefore     make sure that no password is identical with the beginning of another password     e Should you use such confusing passwords for switch control  you have to enter the  longer password  by phone  with asterisks at the beginning and end    e  f Helios refuses to store a password  it means that the switch password list is full   or the password has already been entered    e The switch password may not be identical with any Arrival Departure  Day Night  or  service password    e For password selection tips see the Instructions for Keypad Use     Deleting All Passwords  All Memories  Complete Initialisation    The following three functions facilitate your programming by clearing all previous  settings   997   deletes the entire password list f
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Kicker 500 SS Power Amplifier Owner's Manual  1 The Attractions of Soft Modems  LED-580F Manual20140306  Guida operativa attività estrattiva  Platinum SBX User Manual ver 1  NAVIGON 25xx Explorer  Parametric Fortran – User Manual  Tucano One Premium Messenger  Manuel d`utilisation 3M S10 - Lampe VideoProjecteur.info  User`s Manual - Sage ACT! add-ons    Copyright © All rights reserved. 