Home
View Catalog - Thermal Scientific Inc.
Contents
1. lExdusivefeature Catalog Electrical Options Number Requirements High Heat Window amp Light 4420400 115 volts 60 Hz 16 amps 4420401 230 volts 50 60 Hz 13 amps e 4420410 115 volts 60 Hz 16 amps e 4420411 230 volts 50 60 Hz 13 amps e e 16 FlaskScrubber Mobile Glassware Washers Specifications amp Ordering Information All mobile models feature e General specifications described on page 14 e Black melamine covered high density particle board top e Type 304 stainless steel sides e Epoxy coated steel back e Four 2 inch diameter rubber casters e Quick disconnect attachment for inlet water and drain on top of washer e Two aerator adapters for connection to standard 55 64 27 male and 15 16 27 female laboratory faucets e Exterior dimensions 24 5 w x 26 7 dx 37 0 h 62 2 x 67 8 x 93 8 cm e Shipping weight 189 Ibs 86 kg All 115 volt models feature 17 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C e 5 4 163 cm grounded power cord with 20 amp plug e Operation on 115 volts 60 Hz 16 amps All 230 volt models feature 111 2000 watt heater with thermostat to boost water and glassware Catalog Electrical Options temperatures during washing and drying With
2. Product Service 1 800 522 7658 Chapter 6 Troubleshooting PROBLEM CAUSE CORRECTIVE ACTION Electrical duplex Wires not connected Check wire connection or replace outlet no longer has or faulty duplex duplex power Circuit breakers Reset circuit breakers tripped in building electrical supply Service valves no Faulty building Inspect building supply shut off valves longer operate supply and appropriate pressures below 40 PSI Valve no longer Replace valve and check for leaks operates Supply line or outlet Inspect line for leaks and fix any line has leaks leaking plumbing connections Product Service 1 800 522 7658 41 Chapter 6 Troubleshooting Product Service 1 800 522 7658 APPENDIX A FIBERGLASS 30 Hoop COMPONENTS Illustration A 1 indicate the location of the following service parts Fiberglass 30 Hood Replacement Parts Item Quantity Part No Description 1A 1 9817000 Valve Labconco 4 Compression Fitting 1B 1 9817002 Valve Labconco Deionized 4 Compression Fitting IC 1 9818000 Nut Valve Mtg Labconco 2 1 9818700 01 02 03 Knobs Gray Green Blue Orange Yellow Red White Black 04 05 06 07 08 Brown 3A 1 9818800 Hose Barb Gray Neutral or Argon NOT SHOWN 3B 1 9818801 Hose Barb Green Cold Water NOT SHOWN 3C 1 9818802 Hose Barb Blue Gas NOT SHOWN
3. 3 to 158 8 7 gallons 33 liters Glass Glass Plus Science Standard Standard Standard 5 5 t i 10i 20 30 40 2 2 2 4 4 4 PR 4 4 at 4 4 RE RR 4 PR PR 4 207 30 40 71 107 153 41 to 176 41 to 176 41 to 176 Water Consumption 11 6 gallons 17 4 gallons 23 2 gallons 44 liters 66 liters 88 liters User 1 Set User 2 Set Standard Standard 5 5 t 10 10 10 2 2 4 4 PE PR PR ek PE PR PR ek 10 1Oiii 41 to 176 41 to 176 11 6 gallons 11 6 gallons 44 liters 44 liters Program Time minutes 230 Volt 50 60 Hz Models Program Heat Setting Wash 1 Steam Wash 2 Rinse 1 Rinse 2 Rinse 3 Rinse 4 Rinse 5 Rinse 6 Dry Total Factory Set Time minutes Total User Set Time minutes Total Water Consumed with Factory Settings Steam adds 10 minutes to total program time Rinse Only Standard ig al 17 17 to 116 2 5 gallons 9 5 liters Steam may be desd ected Select from 10 20 30 or 40 minute WASH 2 time Plastic Standard 10 RF aN I 10 38 to 167 7 5 gallons 28 4 liters Glass Glass Plus Science Standard High High 5 5 t i 10i 20 30 40 2 2 2 4 20 20 PR 4 4 I 4 4 PR PR 4 PR 4 20t 30 4Oiii 71 136 184 47 to 186 68 to 207 68 to 207 V ater Consumption 10 gallons 15 gallons 20 gallons 37 9 liters 56 8 liters 75 7 liters xx Add 4 minutes for each additional rinse ttt Sded from 0 10 20 30 40 50
4. 55 Product Service 1 800 522 7658 Appendix C Fiberglass 30 Hood Specifications 56 Product Service 1 800 522 7658 APPENDIX D REFERENCES Many excellent reference texts and booklets are currently available The following is a brief listing Laboratory Ventilation Standards Federal Register 29 CFR Part 1910 Non mandatory recommendations from Prudent Practices e Fume hoods should have a continuous monitoring device e Face velocities should be between 60 100 linear feet per minute Ifpm e Average 2 5 linear feet of hood space per person Occupational Health and Safety U S Department of Labor 200 Constitution Avenue N W Washington DC 20210 202 523 1452 Industrial Ventilation ACGIH e Fume hood face velocities between 60 100 Ifpm e Maximum of 125 Ifpm for radioisotope hoods e Duct velocities of 1000 2000 fpm for vapors gasses and smoke e Stack discharge height 1 3 2 0 x building height e Well designed fume hood containment loss lt 0 10 ppm Industrial Ventilation A Manual of Recommended Practice 24 Edition 2001 American Conference of Governmental Industrial Hygienists 1330 Kemper Meadow drive Cincinnati OH 45240 1634 513 742 2020 Product Service 1 800 522 7658 57 Appendix D References ASHRAE 110 1995 Method of Testing Performance of Fume Hoods Evaluates fume hood s containment characteristics e Three part test Smoke generation Face velocity prof
5. ex Centrifugal Concentrators Multiple Sample Agricultural Laboratory and Cold Traps Evaporation Systems Chemstry Products Carts and Benches Protecting your laboratory environment PAN gt Z LABCONCO Labconco Corporation 8811 Prospect Avenue Kansas City MO 64132 2696 Telephone 800 821 5525 or 816 333 8811 Blood Drawing Digital Vacuum FAX 816 363 0130 Chairs Chloridometer Desiccator E MAIL labconco abconco com HOME PAGE www labconco com 5001 CERTIFIED 2004 by Labconco Corporation Printed in the U S A Product design subject to change without notice 2 10 2 04 SUN 10M R1 User s Manual Fiberglass 30 Laboratory Fume Hoods Models 3030000 3030001 3030002 3030003 3030004 3030005 Register your product online at www labconco com productreg html t or return the attached card and receive FREE LabbyWear Labconco s Mascot Labby the LABster Protecting your __ laboratory environment r V7 LABCONCO LABCONCO CORPORATION 8811 PROSPECT AVENUE KANSAS CITY MO 64132 2696 800 821 5525 816 333 8811 FAX 816 363 0130 E MAIL labconco labconco com HOME PAGE www labconco com Product designs are subject to change without notice 2003 Labconco Corporation Printed in U S A Copyright Information Copyright 2003 Labconco Corporation All rights reserved Labconco Corporation 8811 Prospect Avenue Kansas City Missouri 64132 The information contai
6. up to 6 and dry time 10 USER land 2 SETS Two washes two rinses and dry sequence User selects second wash time number of rinses up to 6 and dry time Two separate programs may be customized and stored in memory Displays total pro grammed wash time in minutes induding drain fill wash and rinse times Or while operating the total wash time remaining is displayed DRY Displays programmed dry time in minutes While operating the dry time remaining is displayed LCD Displays program selected RINSE ONLY PLASTIC GLASS GLASS PLUS SCIENCE USER 1 SET USER 2 SET or details of the program time in minutes for WASH 1 WASH 2 TOTAL WASH and DRY and number of rinses While oper ating the specific func tion in process the wash time remaining and the dry time remaining are displayed Program change buttons Alter the parameter WASH 2 TIME NUMBER OF RINSES and DRY TIME when parameters of the program selected are displayed Program Heat Setting Wash 1 Steam Wash 2 Rinse 1 Rinse 2 Rinse 3 Rinse 4 Rinse 5 Rinse 6 Dry Total Factory Set Time minutes Total User Set Time minutes Total Water Consumed with Factory Settings D FlaskScrubbers amp SteamScrubbers Flexible Cycle Options Program Time minutes 115 Volt 60 Hz Models Rinse Only Standard 13 to 108 2 9 gallons 11 liters Plastic Standard 10 BN I 10
7. 11 liters e Hot tap water pressure at the washer of 20 120 psi e Hot tap water flow of 1 25 gallons 4 7 liters per minute e 3 8 ID copper tubing or flexible hose for connection to the water inlet valve e Purified water with supply piping of a minimum 3 8 ID to permit at least 1 25 gallons 4 7 liters per minute flow Optional companion products and accessories include e Base Stand See page 26 e Adjustable Height Upper Rack See page 26 e Upper Spindle Rack See page 26 e Pipet Inserts See page 27 e Basket Inserts See pages 26 27 e LabSolutions Detergents and Rinse See page 28 e Laboratory Glassware Carts See page 28 e WaterProe RO Stations and Softeners See page 29 FlaskScrubber Undercounter Glassware Washers Specifications amp Ordering Information All undercounter models feature e General specifications described on page 14 e Four leveling feet e 3 8 IPS inlet fitting for hot tap water connection e Factory installed drain hose and band clamp e Exterior dimensions 24 0 w x 26 4 d x 34 3 h minimum to 36 3 h maximum 60 9 x 67 1 x 87 1 cm minimum to 92 1 cm maximum e Shipping weight 142 Ibs 64 kg All 115 volt models feature 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C e Operation on 115
8. 3D 1 9818803 Hose Barb Orange Air NOT SHOWN 3E 1 9818804 Hose Barb Yellow Vacuum NOT SHOWN 3F 1 9818805 Hose Barb Red Hot Water NOT SHOWN 3G 1 9818806 Hose Barb White Deionized Water NOT SHOWN 3H 1 9818807 Hose Barb Black Neutral or Steam NOT SHOWN 3I 1 9818808 Hose Barb Brown Nitrogen NOT SHOWN 3J 1 9819000 Nut Hose Barb NOT SHOWN 4 1 9825500 Label Knob contains all labels 5 1 9818900 Lens Knob 6A 1 2832600 Fixture Kits CW 6B 1 2832601 Fixture Kits HW 6C 1 2832602 Fixture Kits DI 6D 1 2832603 Fixture Kits VAC 6E 1 2832604 Fixture Kits AIR 6F 1 2832605 Fixture Kits GAS 6G 1 2832606 Fixture Kits NIT 6H 1 2832607 Fixture Kits ARG 61 1 2832608 Fixture Kits STM TA 1 2834800 115V 20A Duplex Kit 7B 1 2834801 115V 20A GFCI Duplex Kit Product Service 1 800 522 7658 43 Appendix A Fiberglass 30 Components Item Quantity Part No Description 7C 1 9818200 Cover Plate 115V Duplex 7D 1 9818100 Cover Plate 115V GFCI TE 1 9818300 Wallplate Blank 8A 1 1273600 Bulb 115V 8B 1 1273700 Bulb 230V 8C 1 4849800 Light Fixture Assy complete with wiring parts 8D through 8G Light Fixture a Body amp Socket VFB15 b Pendent Cover 1 2 VP1 BP 2807900 c G
9. 49 5 x 22 2 x 15 2 cm Shipping weight 2 0 Ibs 0 9 ko 27 Multi Pin Insert 4404901 Forty two pins accommodate a variety of labware Type 304 stainless sted Stainless steel pins have plastic tips to protect Glassware from scratching Dimensions 8 3 w x 19 3 dx 5 0 h 21 x 48 9 x 12 7 cm Shipping weight 2 2 Ibs 1 kg Petri Dish Insert 4404201 For petri dishes watch glasses and microtiter plates Capadty 24 plates Grid size 22 mm x 140 mm Type 304 stainless steel Dimensions 19 3 vv x 8 5 dx 5 3 h 48 9 x 21 6 x 13 3 cm Shipping weight 2 Ibs 1 kg DNA Sequencing Plate Insert 4519000 For electrophoresis plates 10 x 16 6 Capadty 6 plates Type 304 stainless steel with plastic glides Dimensions 17 wide x 8 7 8 deep x 9 9 10 high 43 3 x 22 5 x 25 1 am Shipping weight 6 lbs 2 7 kg Pipet Inserts Permit direct injec tion deaning of pipets Self sealing silicone check valves allow washing of partial or full loads Type 304 stainless steel FlaskScrubber and FlaskScrubber Vantage Series Washers hold up to four 4494200 or two 4494301 Inserts Description Shipping Weight Holds 8 pipets 1 ml to 10 ml 15 lbs 0 7 kg Indudes 1 each 1 25 mounting spindle Holds 14 pipets 1 ml to 50 ml 2 0 Ibs 0 9 kg Indudes 2 each 1 25 mounting spindles and PVC coated holder Glassware Holders Two of each size are included with every FlaskScrubber and FlaskScrubber Va
10. Basic Spray Pattern Spray Pattern with Accessory U pper Spindle Rack and Hub Adapter See page 26 for Upper Spindle Rack ordering information Spray Pattern with Accessory Adjustable Height Upper Rack and Hub Adapter See page 26 for Adjustable Haight U pper Rak ordering information FlasicScrubber Vantage Series Glassware Washers Specifications amp Ordering Information All models feature e Type 304 mirror finish stainless steel tank wash arm and tower e Type 304 brushed stainless steel door and sides e Epoxy coated steel back e Two rows of polypropylene rollers in tank for accessory upper rack e Fiberglass blanket and aluminum backed acoustic material for thermal and sound insulation e Operation at 62 dB e Draw latch to energize electronic controls when locked e Made in the U S A e Injection molded panel has microprocessor that stores seven preset programs RINSE ONLY PLASTIC GLASS GLASS PLUS SCIENCE USER 1 SET and USER 2 SET Except for RINSE ONLY and PLASTIC steam program parameter may be altered by the user Except for RINSE ONLY program parameters WASH 2 time WASH 2 temperature detergent dispense amount number of rinses number of pure rinses last rinse temperature rinse aid dispense amount and dry time may be altered For RINSE ONLY program parameters number of rinses num ber of pure rinses and dry time may be altered START CANCEL but ton initiates program or terminates a c
11. DO NOT LIFT BY THE FRONT AIR FOIL Do not move the hood by tilting it onto a hand truck Product Service 1 800 522 7658 Chapter 3 Getting Started Removing the Shipping Skid LEAVE THE FUME HOOD cs ATTACHED TO ITS SHIPPING SKID UNTIL IT IS AS CLOSE TO ITS FINAL LOCATION AS POSSIBLE MOVE THE HOOD BY USING A SUITABLE FLOOR JACK OR BY PLACING A FURNITURE DOLLY UNDERDNEATH THE SKID DO NOT MOVE THE HOOD BY TILTING IT ONTO A HAND TRUCK After you verify the fume hood components move your hood to the location where you want to install it Sash Weight Release To protect the fume hood from damage in shipment the sash weight has been secured to the back of the fume hood with four 4 screws Simply remove the screws and make sure the sash cables are on the pulleys before operation of the sash NOTE THE SASH WEIGHT IS MATCHED IS TO THIS SPECIFIC HOOD AND SHOULD NOT BE EXCHANGED ON ANY OTHER UNIT Install the Fiberglass 30 Hood on a Supporting Structure and Work Surface The Fiberglass 30 Hood is heavy Use caution when lifting or moving the unit When installing the Fiberglass 30 Fume Hood onto a chemically resistant work surface or benchtop ensure Product Service 1 800 522 7658 11 Chapter 3 Getting Started 12 that the structure can safely support the combined weight of the fume hood and any related equipment The work surface should be at least as wide as the hood to properly support it The w
12. e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 am e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 20 e Hard wiring to a 20 amp dedicated circuit e Drain air gap e Drain tubing or pipe 1 2 1 3 cm diameter or larger Te xdusive feature Catalog Electrical Number Requirements 4400300 115 volts 60 Hz 16 amps 4400301 230 volts 50 60 Hz 13 amps 4400310 115 volts 60 Hz 16 amps 4400311 230 volts 50 60 Hz 13 amps Options High Heat Window amp Light SteamScrubber Freestanding Glassware Washers Specifications amp Ordering Information All freestanding models feature e General specifications described on page 20 e Black melamine covered high density particle board top e Type 304 stainless steel sides e Epoxy coated steel back e Four leveling feet e 3 8 IPS inlet fitting for hot tap water connection e Factory installed drain hose and band clamp e Exterior dimensions 24 5 vv x 26 7 d x 35 1 h minimum to 37 1 h maximum 62 2 x 67 8 x 89 2 cm minimum to 94 2 cm maximum e Shipping weight 189 Ibs 86 kg All 115 volt models feature 111 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C
13. for each of the last two rinses Indicator illumi nates amber when this function is activated STEAM During program selection designates steam to be added before WASH 2 cyde to any program except RINSE ONLY and PLASTIC Indicator illu minates amber when this function is activated TOTAL WASH and DRY SHIFT PROG SCIENTFIC USER SE USER 2 SET PROGRAMS Microprocessor control allows the user to select from one of five preset programs RINSE ONLY PLASTIC GLASS GLASS PLUS and SCIENCE or customize 2 different USER SET programs All programs may be altered by the user see charts on page 5 Cycle parameters selected by the user for USER 1 SET and USER 2 SET are stored in memory and can be recalled and repeated indefinitely Cyde parameter changes made to the preset programs affect the current cycle only RINSE ONLY One purified or tap water rinse and drain User may alter number of rinses up to 5 and add dry time PLASTIC One wash two rinses and dry sequence User may alter number of rinses up to 6 and dry time SCIENCE Two washes steam six rinses and dry sequence User may alter second wash time number of rinses and dry time GLASS Two washes two rinses and dry sequence User may alter second wash time number of rinses up to 6 and dry time GLASS PLUS Two washes four rinses and dry sequence User may alter second wash time number of rinses
14. hardness test strips For 115 volt 60 Hz 1 amp operation Indudes 8 foot 3 wire cord and plug Shipping weight 65 Ibs 29 5 kg WaterPro Softener 9073301 Same as 90733 00 except for 230 volt 50 Hz 0 5 amp operation Includes 8 foot 3 wire cord Plug is required International dectrical configuration Dan All Washer Models Typical Plumbing Connections This diagram illustrates the possible connections of various WaterPro Water Purification System components FlaskScrubber Vantage Series Flask Scrubber or SteamScrubber Glassware Washer Purified Water Inlet Valve Hot Water Inlet Valve This diagram illustrates possible connections of the washer s purified water inlet valve to purified water stored in a carboy As shown the connection may be made through the top or bottom of the carboy Clamp vveight to hose so it stays submerged Cut hose to a V Connedion through configuration for top of carboy siphoning Open for vent FlaskScrubber or SteamScrubber Glassware Washer Carboy Purified Wate Pump Connection through Purified Water bottom of carboy Inlet Valve 30 Contact Labconco for more information about these quality products for your laboratory i Perrine Libres Tissus Ta Fume Hoods and HEPA Filtered Safety Glove Boxes Laboratory Animal Water Purification Carbon Filtered Cabinets Clean Benches Research Stations Systems Endosures and Endosures Eci Hia
15. 20 Amp or 230 Volt 50 Hz 10 Amp electrical services The number of circuits varies depending on Product Service 1 800 522 7658 Chapter 3 Getting Started the model All of the electrical connections are terminated at the single point internal junction box for hook up by a qualified electrician Refer to the wiring diagram for your Fiberglass 30 Hood in Appendix C Fiberglass 30 Fume Hood Specifications Internal Junction Box Figure 3 2 All wiring for the fume hood SHOULD be performed by a licensed electrician and conform to all local codes In most cases the hood will require the use of shielded conduit to protect the wiring into the hood The grounding connection shall not be made to the terminal box cover The incandescent light has been mounted inside the top liner panel and is sealed from vapors inside the hood structure To change the incandescent light bulbs in your hood you must first remove the protective glass Replace the defective bulbs and reassemble Product Service 1 800 522 7658 15 Chapter 3 Getting Started Connecting the Service Lines to the Fiberglass 30 Fume Hood The hoods with service fixture kits are plumbed from the valve to the hose connector Supply tubing shall be provided by the qualified installer Tubing can enter the hood from above through the back or through the work surface to make these connections to the service fixtures NOTE Inspect all fittings for l
16. 4 OD Frame dimensions 18 8 w x 21 0 dx 5 high 47 8 x 53 3 x 12 7 am Shipping weight 18 Ibs 8 2 kg FlaskScrubber Adjustable Height Upper Rack 4494401 Expands capacity of FlaskScrubber or FlaskScrubber Vantage Series Washer to handle additional labware especially beakers Type 304 stainless steel rack with acetal rollers includes two 24 pin basket inserts that may be positioned on the rack high or low to accommodate various glassware heights Pins have protective plastic tips In the upper position insert s hold beakers up to 250 ml while flasks up to 1 liter may be washed on the spindle rack below In the lower postion insert s hold beakers up to 600 ml while flasks up to 500 ml may be washed on the spindle rack below Includes two hub adapters one short one tall for connection to the spindle rack The hub adapter sprays the Upper Rack area with water and detergent Also includes rails and end caps for installation on the washer Dimensions 18 8 w x 21 0 d x 5 0 h 47 6 x 53 3 x 12 7 am Shipping weight 8 Ibs 3 6 kg SteamScrubber Adjustable Height Upper Rack 4494501 May be used in place of the Standard Upper Rack in any SteamScrubber Type 304 stainless steel rack with acetal rollers includes two 24 pin Type 304 stainless steel insert baskets that may be positioned on the rack high or low to accommodate various glassware heights Stainless steel pins have plastic caps to protect glassware from scratching
17. 5 Ibs 2 3 am Culture Tube Inserts Choose from three inserts designed to hold tubes from 10 to 24 mm OD Type 304 stainless steel Catalog Description Dimensions Grid Size Shipping Wt 4401301 242 tubes 18 0 w x 8 8 dx4 5 h 15mmx 4 Ibs gar dv 10mmto12mm 45 7 x 22 2 x 11 40m 15 mm 2 ko 4402001 144 tubes 19 3 w x 8 8 dx8 0 h 195mmx 25lbs TM dv 15mmto18mm 48 9 x 22 2 x 20 3 cm 19 5mm 1 2 kg 4402101 105 tubes 19 3 w x 8 8 dx 8 0 h 24mmx 2 5 Ibs BY dv 20mmto 24mm 48 9 x 22 2 x 20 3 cm 24 mm 12 kg 4401401 Retainer 18 5 w x 8 4 dx 0 3 h 24mmx 1 5 Ibs pav dv Top 47 x 21 3 x 0 6 am 24 mm 0 7 kg Indudes 4401401 Retainer Top Labware Inserts Pins hold a variety of wider mouth flasks beakers and other labware in inverted position Retainer Top is recommended for use with plastic and lightweight glassware Inserts and Retainer Top of type 304 stainless steel Stainless steel pins have plastic tips to protect glassware from scratching Catalog Description Dimensions Shipping Weight 4401501 10 Pin Insert 19 3 w x 8 8 d x 8 0 h 2 5 lbs 1 1 kg 49 3 x 22 2 x 20 3 m 4401801 32 Pin Insert 19 3 w x 8 8 d x 6 0 h 2 5 lbs 1 1 kg 49 3 x 22 2 x 20 3 m 4401901 Retainer Top 18 5 w x 8 0 d x 0 3 h 1 5 Ibs 0 7 kg 47 x 20 3 x 0 6 cm BOD Bottle Insert 4404801 Type 304 stainless steel Capacity 18 bottles Grid size 70 mm x 70 mm Dimensions 19 5 w x 8 8 d x 6 0 h
18. Points Wash 1 Time min 5 5 5 i 5 5 Steamt N YorN N YorN Y YorN N YorN N YoN Wash 2 Time min 10 10 40 20 10 40 30 10 40 40 10 40 10 10 40 10 10 40 Wash 2 Temp C 60 38 60 60 38 60 82 38 82 82 38 82 60 38 82 82 38 82 Detergent Dispense ml 20 0 40 20 0 40 20 0 40 20 0 40 20 0 40 20 0 40 Number Rinses 1 1 6 2 1 6 2 1 6 4 1 6 6 1 6 2 1 6 2 1 6 Number Pure Rinsest 0 0 6 0 0 6 0 0 6 0 0 6 2 0 6 0 0 6 0 0 6 Last Rinse Temp C 60 38 60 60 38 60 82 38 82 82 38 82 60 3882 82 38 82 Rinse Aid Dispense ml 0 0 6 0 0 6 0 0 6 0 0 6 0 0 6 0 0 6 Total Wash Time min it 11 11 69 38 28 116 59 39 137 88 39 137 131 39 137 49 39 147 49 39 137 Dry Time min 0 Oor 15 Oor 20 Oor 30 Oor 40 Oor 15 Oor 15 0or 15 99 15 99 15 99 15 99 15 99 15 99 15 99 Cool Time min 40 40 40 43 43 40 40 Total Water Consumed Gallons 29 29 174 87 58203 116 87 232 174 87 232 23 2 87 232 116 87 232 116 8 7 232 Liters 11 11 66 33 22 168 44 33 88 66 33 88 88 33 88 44 33 88 44 33 88 Steam timeis 10 minutes Each rinseis 4 minutes and uses 2 9 gallons 11 liters of water Each purerinse adds 1 minute and uses 2 9 gallons 11 liters of water Total wash time does not indude time required to heat feedwater to set point temperature Automatic neutralizing rinse solution dispenser When pro grammed to dispense from 1 to 6 milliliters a peristaltic pump automatically draws Lab
19. a minimum Number Requirements High Heat Window amp Light inlet temperature of 120 F 49 C the heater elevates water 4420000 115 volts 60 Hz 16 amps temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is selected or approximately 60 F 33 C 2001 230 volts 50 60 Hz Bamps when GLASS PLUS SCIENCE or USER 2 SET is selected 4420010 115 volts 60 Hz 16 amps e e 5 4 163 cm grounded power cord A 20 amp plug is required 4420011 230 volts 50 60 Hz 13 amps z e Operation on 230 volts 50 60 Hz 13 amps e CE Conformity marking Models 4420010 and 4420011 feature e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 am e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 14 e 20 amp dedicated circuit e Electrical plug 230 volt models Exdusive feature wil Easy installation To begin operation hot tap water purified water a drain and electricity are required Mobile models feature a quick disconnect attach ment for tap water and drain Undercounter and freestanding models have straight line plumbing and electrical connections accessible from the front Higher built in drain loca tion prevents self draining and plumbing errors Upper and lower rotating wash arms with adjustable height center OO tower Distribute up to 60 gallons 227 liters o
20. at 60 Hz throughout the tank during wash cycle e One piece stainless steel fine mesh particle filter e Purified water pump to bring pressurized or non pressurized purified water into the tank for the last two rinses e Spindle rack 20 9 vv x 20 dx 11 6 h 53 x 51 x 35 cm of Type 304 stainless steel Includes 34 detachable spindles 24 each tall 8 4 x 25 OD and 10 each small 4 5 x 125 OD 24 large height adjustment clips 10 small height adjustment dips 14 nylon plugs two 4 inch Glassware Holders 4424600 and two 6 inch Glassware Holders 4424800 ESlexdusve teature 14 e Steam generator that produces hot vapor before the WASH 2 cycle RINSE ONLY and PLASTIC excluded 11 Vacuum drying system to draw moist air from glassware through the spindles and drying manifold e Purified water inlet valve with a plastic serrated connector to accommodate a 3 8 ID flexible plastic or rubber hose hose not induded e 2 year warranty on parts and labor All models conform to the following e UL 3101 1 61010 1 e CAN CSA C22 2 No 1010 1 e CE Conformity Marking 230 volt models All models require not included e Minimum inlet water temperature of 120 F 49 C e Recommended inlet water temperature of 140 F 60 C e Minimum inlet water pressure of 20 psi e Maximum inlet water pressure of 120 psi e Minimum purified water pressure of 0 psi e Water consumption per fill of 2 9 gallons
21. during final two rinses Quiet energy efficient operation at 62 decibels Aluminum backed sound deadening insula tion and fiberglass blanket absorb noise optimize internal tank temperature and conserve energy Rollers on the tank interior accommodate an optional upper rack accessory sold separately The optional Upper Spindle Rack holds an additional 24 pieces of narrow neck labware Adjustable Height Upper Rack holds many types of labware especially beakers See page 26 for ordering information Dispenser for neutralizing solution Allows manual addition of mildly acidic rinse aid to alter pH and eliminate alkaline deter gent carry over Attractive Type 304 brushed stainless steel door Mobile and free standing models also have brushed stainless steel sides and epoxy coated steel backs Built in heater Boosts water and glassware tem peratures to enhance washing and drying results by applying heat during all cycles Models for operation on 115 volts have 1200 watts of heat ing power 230 volt mod els have 2000 watts With a minimum inlet tempera ture of 120 F 49 C the heater elevates water temperature approximately 20 F 11 C on 115 volt models and 60 F 33 C on 230 volt models FlaskScrubbers Options Viewing window with interior light Models with built in viewing window and interior light are available as standard options The clear tempered Safety glass wi
22. e CE Conformity marking Models 4400010 and 4400011 feature e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 cm located in the door e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 20 20 amp dedicated circuit e Electrical plug 230 volt models Texdusive feature 23 a i FlaskScrubbers amp SteamScrubbers Dimensional Data Undercounter Models 4420300 4420301 4420310 4420311 4400300 4400301 4400310 4400311 49 0 _ 26 4 Optional window 33 4 34 3 un 36 3 max 24 0 gt FRONT SIDE Freestanding Models 4420400 4420401 4420410 4420411 4400400 4400401 4400410 4400411 lt _ 49 3 26 7 k 26 0 Optional window SIDE 24 lt a FlaskScrubbers amp SteamScrubbers Dimensional Data Mobile Models 4420000 4420001 4420010 4420011 4400000 4400001 4400010 4400011 49 3 Pressure astic Release Ring sa 26 7 A i Drain Hose 26 0 i F el Hose End Coupling Quick Disconnect Attachment Optional window Faucet 34 2 37 0 External T Thread on Faucet Adapter Internal gt Fitting Thread on us I Faucet gt Aerator Aerator Adapter Adapter Aerator Adapters 3 3 Fit standard 55 64 27 male and 15 16 27 fem
23. e Temperature stable Use in hot or cold water Catalog 4522000 Description Shipping Weight Liquid Detergent for 1 gal 3 8 liters approximately 180 loads 28 LabSolutions Neutralizing Acid Rinse e Specially formulated for Labconco glassware washers Dispenses automatically in FlaskScrubber Vantage Series Washers e Mild acid corrects pH reducing alkaline detergent residue e Removes hard water deposits mineral deposits accumulated salts or lime scale that can cloud glassware e Rinses completely Catalog Description Shipping Weight 4522200 Neutralizing Acid Rinse 34 oz 1 liter fills reservoir approximately 6 times For MSDS information visit our website at www labconco com or call customer service at 800 821 5525 or 816 333 8811 Glassware Cart 8032500 Glassware Carts e Safely transport clean and dirty labware e Come with two large or four small interchangeable vinyl coated wire baskets e 4 diameter casters two with toe locks e Indude removable drip pan below the baskets to catch spills e Constructed of welded 1 inch square tubular steel coated with mar resistant epoxy e Dimensions 34 9 vv x 19 0 d x 36 4 h 88 6 x 48 3 x 92 4 am e Fully assembled Glassware Cart 8045000 e Lifetime warranty Catalog Description Shipping Weight 8032500 2 Basket Glassware Cart 43 lbs 19 5 kg 8045000 4 Basket Glassware Cart 43 lbs 19 5 kg 8040100 Large Basket 32 0 w x 18 0 dx 4
24. equipped with a factory wired incandescent light to illuminate the hood interior Simply turn the light switch to ON to operate Explosion proof models do not have a light Working in your Fiberglass 30 Fume Hood Planning e Thoroughly understand procedures and equipment required before beginning work e Arrange for minimal disruptions such as room traffic or entry into the room while the hood is in use Start up e Turn on incandescent light and hood blower e Slowly raise the sash e Check the baffle air slots for obstructions e Allow the hood to operate unobstructed for 5 minutes e Wear a long sleeved lab coat and rubber gloves Use protective eyewear Wear a protective mask if appropriate Loading Materials and Equipment e Only load the materials required for the procedure Do not overload the hood e Do not obstruct the front air foil or rear baffle slots e Large objects should not be placed close together and spaced above the work surface to permit airflow to sweep under the equipment Product Service 1 800 522 7658 Chapter 5 Using Your Fiberglass 30 Fume Hood e After loading the hood wait one minute to purge airborne contaminants from the work area Work Techniques e Keep all materials at least 6 inches inside of the sash and perform all contaminated operations as far to the rear of the work area as possible e Segregate all clean and contaminated materials in the work area e Avoid u
25. 0 h 81 3 x 45 7 x 10 2 cm 5 Ibs 2 3 kg 8040200 Small Basket 16 0 w x 18 0 d x 4 0 h 40 6 x 45 7 X 10 2 cm 2 Ibs 0 9 kg All Washer Models Companion Products WaterPro RO Station 9075000 WaterPro RO Stations Connect to the SteamScrubber or FlaskScrubber to provide purified water for the rinse cycles e Use carbon filtration and reverse osmosis technologies to purify water Deliver 1 liter minute of reverse osmosis purified Type III water when feedwater purity is 100 us or better e Available for wall mounting or with an accessory stand for bench mounting WaterPro RO Station 9075000 Epoxy coated steel cabinet with Type 304 stainless steel front panel Three bowls made of white polypropylene Includes inte gral 17 liter polyethylene storage tank with outlet port for con nection to washer ON OFF switch uS TEMP C TIME DISP and TANK FULL indicator lights and DISPENSE switch If TIME DISP is activated water dispensing from the valve automatically shuts off once user set time has elapsed LED display shows actu al water quality from 1 to 999 microsiemens uS actual water temperature in C or dispense time in minutes For 115 volt 60 Hz 12 amp AC operation Includes an 8 foot 3 wire cord and plug Requires Prefilter Carbon Filter Kit 9067201 and Reverse Osmosis Membrane 9078700 for operation Dimensions 31 1 8 w x 7 7 8 d x 30 3 8 h 79 x 20 x 77 cm Shipping weight 100 I
26. 01102 and Bottom Rack 4401202 included Basket inserts sold separately e Steam generator that produces hot vapor before the WASH 2 cycle RINSE ONLY and PLASTIC excluded e Purified water inlet valve with a plastic serrated du connector to accommodate a 3 8 ID flexible regi plastic or rubber hose hose not included e2 year warranty on parts and labor e Operation at 62 dB e Draw latch to energize electronic controls when locked All models conform to the following e Made in the U S A e UL 3101 1 61010 1 e Injection molded control pane with microprocessor that stores e CAN CSA C22 2 No 1010 1 five factory preset programs RINSE ONLY PLASTIC GLASS I f GLASS PLUS SCIENCE USER 1 SET and USER 2 SET Except CE Conformity Marking 230 volt models for RINSE ONLY program parameters WASH 2 time number of rinses and DRY time may be altered For RINSE ONLY pro All models require not included gram parameters number of rinses up to 5 and DRY time may e Minimum inlet water temperature of 120 F 49 C be altered START CANCEL button initiates the program select E E ed or terminates the cyde in progress SELECT PROGRAM e Recommended inlet water temperature of 1407 F 60 C allows selection of the program SHIFT button activates the display to show parameters of the selected program Program change buttons alter the parameter second wash time number e Maximum inlet water pressure of 120 psi of rinses and d
27. 30 Fume Hood Routine Service Operations Front Panel Removal 1 Simply lift the front panel up and then away from the hood to provide access to the top Changing the Incandescent Lamp 1 Turn light switch to OFF 2 Raise the sash and reach inside the fume hood to unscrew the clear glass globe that protects the incandescent bulb 3 Install the new incandescent bulb and then reverse the removal procedure Your Next Step After you understand the maintenance procedures you are ready to proceed to Chapter 7 Modifying Your Fiberglass 30 Fume Hood Product Service 1 800 522 7658 33 Chapter 6 Maintaining Your Fiberglass 30 Fume Hood 34 Product Service 1 800 522 7658 CHAPTER MopiFYiNG Your FIBERGLASS 30 Fume Hoop There are several ways to modify the fume hood for your individual requirements These include the addition of work surfaces service fixtures air monitor and electrical duplex outlets See Appendix A Fiberglass 30 Hood Components for installation location Installing Work Surfaces and Storage Cabinets d An optional work surface is available when installing the hood on storage cabinets Contact Labconco Customer Service for ordering information on these 30 work surfaces and storage cabinets 4882806 Work Surface 30 x 30 9902200 Solvent Cabinet 30 9901200 Acid Cabinet 30 9900200 Base Cabinet 30 Product Service 1 800 522 7658 35 Chapter 7 Modifying Your F
28. 38 to 60 C and dry time amount number of rinses number of pure rinses automatic rinse aid dispense amount last rinse temperature from 38 to 82 C and dry time SCIENCE Two washes steam sx rinses and dry sequence User may alter steam addition second wash time second wash temperature from 38 to 82 C automatic detergent dispense amount number of rinses number of pure rinses automatic rinse aid dispense amount last rinse temperature from 38 to 82 C and dry time USER 1 and 2 SETS Two washes two rinses and dry sequence User selects steam addition second wash time second wash temperature from 38 to 82 C automatic detergent dispense amount number of rinses number of pure rinses automatic rinse aid dispense amount last rinse temperature from 38 to 82 C and dry time Two separate programs may be customized and stored in memory GLASS PLUS Two washes four rinses and dry sequence User may alter steam addition second wash time second wash temperature from 38 to 82 C automatic detergent dispense Flexible Cycle Options Factory Set Programs and Sdedable Set Points Program Rinse Only Plastic Glass Glass Plus Science User 1 Set User 2 Set Factory Selectable Factory Selectable Factory Selectable Factory Selectable Factory Selectable Factory Selectable Factory Seectable Seting SetPoints Setting SetPoints Setting Set Points Seting Se Points Seting Set Points Setting Set Points Setting Set
29. Dimensions 18 8 w x 21 0 d x 5 0 h 47 6 x 53 3 x 12 7 am Shipping weight 6 5 Ibs 2 9 kg SteamScrubber Standard Upper Rack 4401102 One is induded with every SteamScrubber Large volume users may wish to order additional Upper Racks for effident glass ware handling Type 304 stainless steel with acetal rollers Select accessory Basket Inserts below and on page 27 to suit your glassware mix Dimensons 18 9 w x 21 0 d x 35 h 48 x 53 x 9 cm Shipping weight 7 Ibs 3 2 kg SteamScrubber Standard Bottom Rack 4401202 One is induded with every Steam Scrubber Large volume users may wish to order additional Bottom Racks for efficient glassware han dling Type 304 stainless steel with polypropylene rollers Select accessory Basket Inserts below and on page 27 to suit your glassware mix Dimensions 20 6 w x 21 0 d x 3 3 h 52 x 53 x 9 am Shipping weight 7 5 Ibs 3 4 kg Basket Inserts Use the icon key below to select accessory inserts that fit your washer Each indicated rack can accommodate a maximum of two inserts except Utensil Holders and Utensil Baskets Each indicated rack can hold a maximum of five Utensil Holders or four Utensil Baskets l A Fits in SteamScrubber Upper Rack i VW Fits in SteamScrubber Bottom Rack V Fits in FlaskScrubber and FlaskScrubber Vantage Series Standard Spindle Rack with spindles renoved and plugged A Fitsin FlaskScrubber and FlaskScrubber Vantage Serie
30. EREQUISITES Location Requirements Support Requirements Exhaust Requirements Electrical Requirements Service Line Requirements Space Requirements Your Next Step CHAPTER 3 GETTING STARTED Unpacking Your Fume Hood Removing the Shipping Skid Sash Weight Release Installing the Hood on a Supporting Structure amp Work Surface Connecting to the Hood Exhaust System Connecting the Electrical Supply Source Connecting the Service Lines Sealing the Fiberglass 30 Hood to the Work Surface Certifying the Fiberglass 30 Fume Hood Your Next Step CHAPTER 4 PERFORMANCE FEATURES AND SAFETY PRECAUTIONS Performance Features Safety Precautions Your Next Step BWN NNN NAAA 11 11 11 13 14 16 17 17 18 19 19 23 25 CHAPTER 5 USING YOUR FIBERGLASS 30 Operating the Vertical Rising Sash Operating the Blovver Operating the Lights Working in your Fiberglass 30 Fume Hood Your Next Step CHAPTER 6 MAINTAINING YOUR FUME HOOD Routine Maintenance Schedule Routine Service Operations Your Next Step CHAPTER 7 MODIFYING YOUR FUME HOOD Installing Work Surfaces and Storage Cabinets Installing Additional Service Fixtures Installing Guardian Digital Airflow Monitor or Guardian Jr Installing an Electrical Duplex Receptacle Your Next Step CHAPTER 8 TROUBLESHOOTING APPENDIX A FIBERGLASS 30 COMPONENTS APPENDIX B FIBERGLASS 30 DIMENSIONS APPENDIX C FIBERGLASS 30 SPECIFICATIONS APPENDIX D REFERENCES DECLARATION OF CONFO
31. FPA 30 2000 Flammable and Combustible Liquids Code e Approved cabinets may be metal or wood e Vent location on cabinets are required e Venting of cabinets not a requirement National Fire Protection Association 1 Batterymarch Park P O Box 9101 Quincy MA 02269 9101 800 344 3555 General References American Conference of Governmental Industrial Hygienists Industrial Ventilation A Manual of Recommended Practice Cincinnati OH ASHRAE Standard Committee ASHRAE Standard Atlanta ASHRAE Publications Sales Department 1995 British Standards Institution Laboratory Fume Cupboards Parts 1 2 and 3 London 1990 Department of Labor Occupational Safety and Health Administration 29 CFR Part 1910 Occupational Exposures to Hazardous Chemicals in Laboratories Final Rule Vol 55 No 21 Washington D C 1990 DiBerardinis L et al Guides for Laboratory Design Health and Safety Considerations Wiley amp Sons 1987 McDermott Henry Handbook of Ventilation for Contaminant Control 2 Edition Butterworth Publishers 1985 Miller Brinton M et al Laboratory Safety Principles and Practices American Society for Microbiology Washington D C 1986 NIH Guidelines for the Laboratory Use of Chemical Carcinogens NIH Publication No 81 2385 Rayburn Stephen R The Foundation of Laboratory Safety A Guide for the Biomedical Laboratory Springer Verlag New York 1990 Sax N Irving and Lewis JR Richard J Ra
32. RMITY 27 27 28 28 28 29 31 32 33 33 35 35 36 36 37 38 39 43 47 53 57 61 CHAPTER 1 INTRODUCTION Congratulations on your purchase of a Labconco Fiberglass 30 Laboratory Fume Hood Your Fiberglass 30 Laboratory Fume Hood is designed to protect you It is the result of Labconco s more than 50 years experience in manufacturing fume hoods and users like you suggested many of its features to us The Labconco Fiberglass 30 Fume Hood has been engineered to effectively contain toxic noxious or other harmful materials when properly installed The Fiberglass 30 offers many unique features to enhance safety performance and visibility To take full advantage of them please acquaint yourself with this manual and keep it handy for future reference If you are unfamiliar with how fume hoods operate please review Chapter 4 Performance Features and Safety Precautions before you begin working in the fume hood Even if you are an experienced fume hood user please review Chapter 5 Using Your Fume Hood which describes your Fiberglass 30 features so that you can use the hood efficiently Product Service 1 800 522 7658 Chapter 1 Introduction About This Manual This manual is designed to help you install use and maintain your laboratory fume hood Instructions for installing optional equipment on your hood are also included Chapter 1 Introduction provides a brief overview of the laboratory fume hood expla
33. Solutions Neutralizing Acid Rinse or other mildly acidic rinse aid from a one liter bottle during the rinse cycle INCLUDES Spindle rack with 34 detachable spindles with height adjustment dips Large volumes of water stream into the bulb of each flask for high powered cleaning Clips may be raised and lowered on the 24 tall spindles to accom modate flasks from 50 ml to 2000 ml The 10 small spindles hold flasks from 1 ml to 25 ml Spindles detach easily to cus tomize rack for accessory inserts sold separately See pages 26 and 27 for insert selection Manual dry or liquid detergent dispenser If the automatic liquid detergent dispenser is pro grammed to 0 milliliter then the dispenser in the door is activated Detergent compartments release a manually premeasured amount 1 35 ounces or 40 ml For heavily soiled glassware the pre wash cavities in the lid of the detergent cup or stamped in the door may be filled so that deter gent is released during the first wash cycle Easy installation To begin opera tion tap water purified water a drain and single phase electricity are required For fastest opera tion hot tap water is recom mended Straight line plumbing and electrical connections are accessible from the front Higher built in drain location prevents self draining and plumbing errors The top may be removed for undercounter installation Full two year warranty Is pro vided against defects
34. a pressure regulator to reduce the line pressure Please check with local codes for other requirements Space Requirements The dimensions for the different models are shown in Appendix B Fiberglass 30 Hood Dimensions Your Next Step After you have determined that the location you have selected accommodates the installation and operational requirements of your fume hood you are ready to begin installation Proceed to Chapter 3 Getting Started Product Service 1 800 522 7658 7 Chapter 2 Prerequisites 8 Product Service 1 800 522 7658 CHAPTER 3 GETTING STARTED Now that the site for your laboratory fume hood is properly prepared you are ready to unpack inspect install and certify your unit Read this chapter to learn how to Unpack and move your Fiberglass 30 Hood Set up the fume hood with the supporting structure and work surface Connect to an exhaust system Connect the electrical supply source Connect the service lines Seal the Fiberglass 30 Hood to the work surface Arrange certification of your Fiberglass 30 Hood Depending upon which model you are installing you may need common plumbing and electrical installation tools in addition to 5 16 3 8 7 16 and 1 2 wrenches ratchets sockets a nut driver set a flat blade screwdriver a Phillips screwdriver and a carpenter level to complete the instructions in the chapter Unpacking Your Laboratory Fume Hood Interstate Commerce Ca
35. ale faucets SIDE Typical Plumbing Connections for Undercounter Model Series 44203 amp 44003 amp Freestanding Model Series 45400 44204 44004 Elevate above sink water level Installation with air gap Installation without air gap Installation with and connection to sink drain and connection to sink drain connection to floor drain 25 All Washer Models Accessories Base Stands Elevate washer 17 43 2 cm for washer loading convenience and storage of sup plies Type 304 stain less steel stationary stand fully assembled with leveling feet and instructions Catalog Description Shipping Wt 4536400 Stand for FlaskScrubber Vantage Series 40 Ibs 18 1 kg 36 75 w x 25 6 dx 17 0 h 93 3 x 65 0 x 43 2 cm includes two storage compartments with hinged doors Stand for Freestanding or Mobile FlaskScrubbers or SteamScrubbers 24 0 w x 25 6 dx 17 0 h 62 0 x 65 0 x 43 2 cm includes one storage compartment with hinged door 30 Ibs 13 6 kg FlaskScrubber Upper Spindle Rack 4525000 Fits in any FlaskScrubber or FlaskScrubber Vantage Series Washer manufactured after 8 13 01 Constructed of Type 304 stainless steal with nylon center spray nozzle Indudes 24 each removable spindles 24 each adjustable height dips 24 each nylon plugs distribution tube adapter and two side rails Spindles may be removed and plugged to accommodate various accessory inserts sold separately Spindle dimen sons 4 high x 1
36. bs 45 kg 29 WaterPro RO Station 9075002 Same as 9075000 except for 230 volt 50 Hz 60 amp AC operation Includes an 8 foot 3 wire cord An electrical plug is required Prefilter Carbon Filter Kit 9067201 Required for operation Includes Prefilters 3 and Carbon Filters 3 for initial start up and two filter changes Shipping weight 10 Ibs 4 5 kg Reverse Osmosis Membrane 9078700 Required for operation Shipping weight 6 Ibs 2 7 kg Support Stand 9077400 For converting wall mounted WaterPro RO Station to bench mounted Rests on countertop or other horizontal surface Epoxy coated steel Dimensions with WaterPro RO Station attached 31 1 8 w x 16 1 8 d x 35 1 3 h 79 x 41 x 90 cm Shipping weight 20 Ibs 9 kg WaterPro Softeners e Soften tap water to pro tect washer components from scaling and to help activate detergent e Twelve day timer auto matically regenerates resins e Large capacity 20 brine sump holds enough salt to provide three regenera tions before refilling is necessary e Produce over 600 gallons 2271 liters of softened water at 8 grains of hard ness before salt replace ment is necessary e Large ion exchange resin capacity provides years of water softening C WaterPro Softener 9073300 WaterPro Softener 9073300 Epoxy coated steel cabinet with Type 304 stainless steel front panel Two white polypropylene sumps Includes 6 color coded
37. coustic material for thermal and sound insulation e Operation at 62 dB e Draw latch to energize electronic controls when locked e Made in the U S A e Injection molded control panel with microprocessor that stores seven preset programs RINSE ONLY PLASTIC GLASS GLASS PLUS SCIENCE USER 1 SET and USER 2 SET Except for RINSE ONLY program parameters WASH 2 time number of rinses and DRY time may be altered For RINSE ONLY program parameters number of rinses up to 5 and DRY time may be altered START CANCEL button initiates the program selected or terminates the cycle in progress SELECT PROGRAM allows selection of the program SHIFT button activates the display to show parameters of the selected program Program change but tons alter the parameter Second wash time number of rinses and dry time when parameters of the selected program are dis played LCD displays selected program or details of the program WASH 1 time WASH 2 time NUMBER OF RINSES TOTAL WASH time and DRY time PURE button selects purified water for the last two rinses STEAM button selects steam to be added before the WASH 2 cycle Amber indicator lights illuminate next to PURE and STEAM buttons when selected e Manual detergent dispenser for powder or liquid detergent Detergent samples are included e Manual rinse solution dispenser Rinse sample is included e Pump with 1 3 hp motor to recirculate up to 60 gallons 227 liters of water per minute
38. d placing your head inside hood Keep hands out of hood as much as practical Always work as far back in the hood as possible It is best to keep all chemicals and apparatus 6 inside the front of the hood Only explosion proof models feature explosion proof electrical components Therefore use of flammable or explosive materials in quantities above the explosive limit are not recommended Do not work with chemicals in this hood without the exhaust system running Do not store chemicals in a fume hood Perchloric acid use in this hood is prohibited High level radioisotope materials are prohibited for use in this hood AVOID CROSS DRAFTS AND LIMIT TRAFFIC IN FRONT OF THE HOOD AIR DISTURBANCES CREATED MAY DRAW FUMES OUT OF THE HOOD Product Service 1 800 522 7658 Chapter 4 Performance Features and Safety Precautions The use of heat generating equipment in this hood vvithout the exhaust system operating properly can cause damage to the hood The Fiberglass 30 Laboratory Hood should be certified by a qualified certification technician before it is initially used The hood should be re certified whenever it is relocated serviced or at least annually thereafter Ensure that the unit is connected to electrical service in accordance with local and national electrical codes Failure to do so may create a fire or electrical hazard Do not remove or service any electrical components without first disco
39. d wash time Displays total number of RINSES Displays programs which is Designates steam to be depending on program Except for RINSE ONLY rinses tap and pure number of pure rinses shown on the display added before WASH 2 selected the set point time may water rinses User may User may choose that cyde to any program be modified from select from 1 to 6 rinses none to all of the num except RINSE ONLY 10 to 40 minutes ber of rinses selected and PLASTIC be pure water If pure water rinses are selected they occur last TOTAL WASH Displays total pro grammed wash time START SELEC a om 3 including drain fill CANCEL PROG E 4 wash and rinse times Or while operating the total wash time remain ing is displayed eo D DRY Displays pro grammed dry time The set point time may be modified to 0 or up to 99 minutes While operating the dry time remaining is displayed DATA SELECT x ENTER SO RORY RESET START CANCEL ters for the program Initiates program shown on the display selected Terminates cyde in progress LCD Displays program selected or details of the Alarm Indicator progam al e Hoa Red light flashes to Parameter chan ing the specific function ge buttons dert user to fault s Press to modify user set points deis dia dry time remaining are DATA Press to view displayed water temperature water conductivity and alarms if any ENTER Press to store mo
40. dified parameter set point into memory and PROGRAMS Microprocessor control allows the user to select from one of five preset programs and two different USER SET programs Programs are described on the follow ing page and may be altered by the user see chart on page 5 All set points are stored in memory so cycles may be easily duplicated to advance the display SELECT Press to see to the next user pro details of the selected grammable parameter program The displayed time does not indude the time required to heat cold inlet water to the set point temperature A FlasicScrubber Vantage Series Laboratory Glassware Washers Flexible Cycle Options Select from Seven Programs with the flexibility to change multiple parameters RINSE ONLY One purified or tap water rinse and drain User may alter number of rinses number of pure rinses and add dry time PLASTIC One wash two rinses and dry sequence User may alter wash time wash temperature from 38 to 60 C automatic detergent dispense amount number of rinses number of pure rinses automatic rinse aid dispense amount last rinse tempera ture from 38 to 60 C and dry time GLASS Two washes two rinses and dry sequence User may alter steam addition second wash time second wash temperature from 38 to 60 C automatic detergent dispense amount num ber of rinses number of pure rinses automatic rinse aid dispense amount last rinse temperature from
41. duct Service 1 800 522 7658 Chapter 4 Performance Features and Safety Precautions Safety Precautions Although the laboratory hood has been engineered to maintain optimum operator safety caution should always be used while working in the hood Prior to using the hood check to make sure that the exhaust blower is operating and that air is entering the hood at its specified face velocity USE GOOD HOUSEKEEPING IN LS THE HOOD AT ALL TIMES CLEAN UP SPILLS IMMEDIATELY PERIODICALLY CLEAN HOOD INTERIOR INCLUDING LIGHT GLASS PANEL REPLACE BURNED OUT LIGHT BULBS TO MAINTAIN MAXIMUM ILLUMINATION DO NOT OVERLOAD THE WORK SURFACE WITH APPARATUS OR WORK MATERIAL THE SAFE OPERATION OF THE LABORATORY HOOD IS BASED UPON HAVING PROPER AIRFLOW THROUGH THE STRUCTURE DO NOT PLACE LARGE BULKY OBJECTS SUCH AS BLOCK HEATERS DIRECTLY ON THE HOOD WORK SURFACE INSTEAD ELEVATE THE OBJECT 2 TO 3 ON BLOCKS TO ALLOW A FLOW OF AIR UNDER THE OBJECT AND INTO THE LOWER REAR BAFFLE EXHAUST SLOT ENSURE BLOCKS ARE LEVEL AND SECURED IN PLACE Product Service 1 800 522 7658 23 Chapter 4 Performance Features and Safety Precautions 1 Blocking the bottom of the baffle at the rear of hood will change the airflow pattern in the hood causing turbulence and possible leakage at the face of the hood Don t store containers or supplies against the baffle as this will affect airflow through the hood Avoi
42. e 1 800 522 7658 13 Chapter 3 Getting Started 14 The exhaust connection should be installed by a qualified HVAC contractor The exhaust connection on your hood has been designed for 6 nominal pipe 6 625 OD to allow for minimum static pressure loss with proper transport velocities away from the hood Consult Labconco Customer Service should you require help sizing your blower for the exhaust volume and total system static pressure loss See Chapter 2 for the hood airflow specifications The selected exhaust duct material should match the hood procedures and chemicals used to ensure compatibility Connecting the Electrical Supply Source to the Fiberglass 30 Fume Hood Prior to connecting any electrical wiring to the fume hood structure refer to the hood identification plate for the proper electrical requirements of your specific model WARNING The building electrical supply system for Fiberglass 30 Hoods should include overload protection A switch or circuit breaker should be in close proximity to the equipment and within easy reach of the operator The switch or circuit breaker is to be marked as the disconnecting device for the equipment Consult the NEC 2002 for proper installation The identification plate model number serial number and electrical connection boxes are accessible from the front of the fume hood by removing the front panel The Fiberglass 30 Hood is normally wired for 115 Volt 60 Hz
43. e Operation on 115 volts 60 Hz 16 amps All 230 volt models feature 2000 watt heater with thermostat to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the heater elevates water temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is elected or approximately 60 F 33 C when GLASS PLUS SCIENCE or USER 2 SET is selected e Operation on 230 volts 50 60 Hz 13 amps e CE Conformity marking Models 4400410 and 4400411 feature e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 am e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 20 e Hard wiring to a 20 amp dedicated circuit e Drain air gap e Drain tubing or pipe 1 2 1 3 cm diameter or larger Exdusive feature Catalog Electrical Options Number Requirements High Heat Window amp Light 4400400 115 volts 60 Hz 16 amps 4400401 230 volts 50 60 Hz 13 amps e 4400410 115 volts 60 Hz 16 amps e 4400411 230 volts 50 60 Hz 13 amps e e 22 SteamScrubber Mobile Glassware Washers Specifications amp Ordering Information All mobile models feature e General specifications described on page 20 e Black melamine covered high density particle board top e Type 304 stainless steel sides e Epo
44. e The location requirements The support requirements The exhaust requirements The electrical power requirements The service line requirements The space requirements Refer to Appendix B Fiberglass 30 Hood Dimensions for complete fume hood dimensions Refer to Appendix C Fiberglass 30 Hood Specifications for complete laboratory fume hood electrical and environmental conditions specifications and requirements Product Service 1 800 522 7658 Chapter 2 Prerequisites Location Requirements The fume hood should be located away from traffic patterns doors windows fans ventilation registers and any other air handling device that could disrupt its airflow patterns All windows in the room should be closed Support Requirements DO NOT install the fume hood on a cart dolly or mobile bench ALL Fiberglass 30 Hood installations must be permanent and stationary The supporting structure usually consists of a base cabinet and chemically resistant work surface See Chapter 7 Modifying Your Fiberglass 30 Hood Exhaust Requirements The exhaust duct connection has been designed for 6 nominal duct 6 625 OD to allow for minimum static pressure loss while operating at 100 fpm face velocities The 6 diameter exhaust duct also allows for proper transport velocities away from the hood in the 1000 fpm to 2500 fpm range The proper exhaust volume and static pressure loss are listed next for each hood model Fiberglas
45. eakage Tighten the fittings slightly if needed CAUTION Do not use oxygen with any standard service fixture Contact Labconco Customer Service for oxygen fixture information Should access to the hood plumbing fixture bodies be required remove the service access plate on the side of the hood by loosening screws The valve body will be fully exposed for any service work that may be necessary The service fixture kits on your laboratory hood are designed for use with the following services e Air e Hot Water e Vacuum e Cold Water e Natural Gas See caution below WARNING Contact Labconco Customer Service directly before using any service other than those listed above in these valves to assure full compatibility 16 Product Service 1 800 522 7658 Chapter 3 Getting Started CAUTION Natural gas should be used only in the service fixture that has been pre plumbed with brass tubing Sulfur content of the gas could cause deterioration of standard copper supply lines Sealing the Fiberglass 30 Hood to the Work Surface When the hood has been set in place ducted wired and plumbed it should be sealed at the work surface to prevent spilled materials from collecting under the walls of the hood Materials such as silicone sealants are recommended to seal the hood structure Certifying the Fiberglass 30 Fume Hood The combination of your laboratory hood exhaust ductwork and exhaust blower give you the flexibility
46. effectively contain toxic noxious or other harmful materials when properly installed The by pass airflow feature allows the hood face velocity to remain relatively stable as the sash is closed The air foil sweeps the worksurface to remove heavier than air contaminants Product Service 1 800 522 7658 19 Chapter 4 Performance Features and Safety Precautions 20 10 11 12 13 Unique sash provides maximum visibility of 28 high while conserving energy by limiting sash travel to 20 Vertical rising sash may be raised from a closed to 20 operating height Exhaust volume and blower sizing is based on the 20 height By pass airflow design ensures relatively stable face velocities Large usable interior work depth and interior height of 36 provides ample working space Baffle not shown directs airflow to the rear of the interior to provide efficient airflow The baffle may be removed for cleaning purposes only Lift Away front panel provides easy access to electrical wiring and sash weights Incandescent lighting provides ample illumination inside the fume hood No lighting is provided on explosion proof models Low mounted factory wired light and blower switches are ADA compliant No switches are provided on explosion proof models Curved Air Foil allows air to sweep the work surface for maximum containment Corner posts provide maximum visibility and the flexibility to add serv
47. els moisture mobile and freestanding models 360 rotating lower wash arm and spindle rack Distribute up to 60 gallons 227 liters of water per minute Full two year warranty Is provided against defects in materials and workmanship gt Exdusive feature Madein theU S A Mirror bright Type 304 stainless sted interior Provides a corrosion resistant surface that reduces contaminant carry over during wash and rinse cycles Dry or liquid detergent dispenser Releases a manually premeasured amount 1 35 ounces or 40 ml ensuring clean labware Particle filter One piece stainless steel screen filters fine particles protecting the pump from broken glass and debris 12 Easy installation To begin operation hot tap water purified water a drain and eledricity are required Mobile models feature a quick disconnect attach ment for tap water and drain Undercounter and freestanding models have straight line plumbing and electrical connections accessible from the front Higher built in drain loca tion prevents self draining and plumbing errors Draw latch Securely locks the door while energizing the electronic controls Steam generator Produces hot vapor to penetrate and soften dried residue allowing detergent and hot water to work effectively Built in purified water pump Draws from a stor age tank or pressurized system to deliver purified water
48. endix C Fiberglass 30 Hood Specifications contains the electrical requirements for laboratory fume hood Wiring diagrams are also included Appendix D References lists the various resources available that deal with laboratory fume hoods Typographical Conventions Recognizing the following typographical conventions will help you understand and use this manual e Book chapter and section titles are shown in italic type e g Chapter 3 Getting Started e Steps required to perform a task are presented in a numbered format e Comments located in the margins provide suggestions reminders and references Product Service 1 800 522 7658 3 Chapter 1 Introduction OU te e Critical information is presented in boldface type in paragraphs that are preceded by the exclamation icon Failure to comply with the information following an exclamation icon may result in injury to the user or permanent damage to fume hood e Critical information is presented in boldface type in paragraphs that are preceded by the wrench icon These operations should only be performed by a trained certifier or contractor Failure to comply with the information following a wrench icon may result in injury to the user or permanent damage to your hood e Important information is presented in capitalized type in paragraphs that are preceded by the pointer icon It is imperative that the information contained in these paragraphs be thoroughly read a
49. eral Specifications 20 Undercounter Glassware Washers Specifications amp Ordering Information 21 Freestanding Glassware Washers Specifications amp Ordering Information 22 Mobile Glassware Washers Specifications amp Ordering Information 23 FlaskScrubbers amp SteamScrubbers Dimensional Data 24 25 Accessories for All Models 26 27 Companion Products for All Models 28 29 Typical Plumbing Connections for All Models 30 Labconco s FlaskScrubber and SteamScrubber Glassware Washers and new FlaskScrubber Vantage Series Glassware Washers have ben engineered with the performance and convenience features that laboratories demand Flexible Programs Flexible cyde programs give the user control in selecting the right combination of parameters A keypad and LCD display allow parameters to be easily set or changed Memory stores both preset and user set programs for reproducible protocols Multiple Rinses Multiple rinses rid glassware of residual contaminants Up to six rinses may be selected for one cycle program Sanitizing High Heat Models High heat models that reach 180 F 82 C effectively remove lipids and sanitize glassware For normal loads or delicate plasticware simply select cycle programs that reach 140 F 60 C or lower Rugged Co
50. ering information Not acceptable on explosion proof hoods The following duplex kits are available 2834800 115V 20A Duplex Kit 2834801 115V 20A GFCI Duplex Kit Figure 7 6 Product Service 1 800 522 7658 37 Chapter 7 Modifying Your Fiberglass 30 Fume Hood Your Next Step After you understand the modifying procedures you are ready to proceed to Chapter 8 Troubleshooting 38 Product Service 1 800 522 7658 CHAPTER 8 TROUBLESHOOTING Refer to the follovving table if your fume hood fails to operate properly If the suggested corrective actions do not solve your problem contact Labconco for additional assistance PROBLEM Remote blover and light won t operate Remote blower won t operate but light works Fume hood blower operates but light will not operate CAUSE Wires not connected at junction box or switches Circuit breakers tripped in building electrical supply Blower wiring is disconnected Belt broken Blower motor is defective Lamp not installed correctly Lamp is defective Circuit breaker in building is tripped CORRECTIVE ACTION Check connection of switches Check connection to control box on top of unit Reset circuit breakers Inspect blower wiring and switch Replace belt Replace blower motor Inspect lamp installation Replace lamp Reset the circuit breaker Product Service 1 800 522 7658 39 Cha
51. f water per minute Wash arms clean with a 360 revolving motion The lower arm pumps water upward through the bot tom rack while the upper arm propels water down across glassware below and up through the top rack The center telescop ing tower has a locking pin that adjusts the upper arm to 2 positions to accommodate various glassware heights ETL listed Washers carry the ETL mark signifying they are certified to UL Standard 3101 1 and CAN CSA C22 2 No 1010 1 CE Mark Washers conform to the CE European Community requirements for electrical safety and electromagnetic compatibility ca SteamScrubbers Features amp Benefits Built in forced air drying system Dries glassware with hot dry air Melamine covered high density partide board top Repels moisture mobile and freestanding models Built in purified water pump Draws from a stor age tank or pressurized system to deliver purified water during final two rinses Full two year warranty Is provided against defects in materials and workmanship Te xdusive feature E Madein the U S A Mirror bright Type 304 stainless steel interior Provides a corrosion resistant surface that reduces contaminant carry over during wash and rinse cycles Dry or liquid detergent dispenser Releases a manually premeasured amount 1 35 ounces or 40 ml ensuring clean labware Particle filter One piece stainless steel screen filters fi
52. g your laboratory environment LABCONCO S a A A ap Q Q mD OU WY D N Va Les D aD OU un un Lo LL un 0D T cad 3 Ae 69 gt o qo e re qo sn d FlaskScrubbers amp SteamScrubbers Table of Contents Overview Overview nn kits ans datat diel se 3 FlaskScrubber Vantage Series Laboratory Glassware Washers Flexible Cyde Options 4 5 Features amp Beneit wii ases da aa dca ua MAA nl 6 7 PA coco MEDI ETC ococodcoodocins 7 Specifications amp Ordering Information 8 DimmenSomaliDAtawees e ea E 9 FlaskScrubbers amp SteamScrubbers Flexible Cycle Options 10 11 FlaskScrubber Laboratory Glassware Washers Features Si BENESI La nua sus eens acs nas PEE 12 Spray Patterns Interior Dimensions amp Options 13 Genefal SpeciiGations APP 14 Undercounter Glassware Washers Specifications amp Ordering Information 15 Freestanding Glassware Washers Specifications amp Ordering Information 16 Mobile Glassware Washers Specifications amp Ordering Information 17 SteamScrubber Laboratory Glassware Washers eatures SE NC ES Ne 18 Spray Patterns Interior Dimensions amp Options 19 Gen
53. heater elevates water temperature approximately 20 F 11 C on 115 volt models and 60 F 33 C on 230 volt models SteamScrubbers Options Viewing window with interior Sanitizing high heat Higher temperature loosens stubborn light Models with built in lipid based residues for cleaner sanitized glassware Models for viewing window and interior operation on 230 volts 50 60 Hz include a high heat option light are available as standard A 2000 watt heater and thermostat allow interior temperatures options The clear tempered to reach a nominal 180 F 82 C with a minimum inlet temper Safety glass window allows ature of 120 F 49 C during the second wash and rinse cycle observation of the cycle in High heat is automatically activated when GLASS PLUS progress A 25 watt interior SCIENCE or USER 2 SET is selected light illuminates the tank while the door latch is engaged Spray Pattern Interior Dimensions 6 5 or 8 8 11 or 8 8 21 a 15 gt FRONT SIDE 19 SteamScrubbers General Specifications All models feature En Type 304 mirror finish stainless steel tank wash arms and adjustable height center tower e Type 304 brushed stainless steel door e Two rows of polypropylene rollers in tank for upper rack adjustment e Fiberglass blanket and aluminum backed acoustic material for thermal and sound insulation e Type 304 stainless steel Upper Rack 44
54. iberglass 30 Fume Hood d Installing Additional Service Fixtures Additional service fixtures can be installed in the available service fixture holes in the right sidewall and corner post The fume hood is factory set to accept up to three valves Contact Labconco Customer Service for information The following service fixture kits are available 2832600 Cold Water CW Green 2832601 Hot Water HW Red 2832602 Deionized Water DW White 2832603 Vacuum VAC Yellow 2832604 Air AIR Orange 2832605 Gas GAS Blue 2832606 Nitrogen NIT Brown 2832607 Argon ARG Gray 2832608 Steam STM Black Figure 7 1 Knob Figure 7 2 Valve Figure 7 3 Hose Connector Airflow Monitor or Guardian Jr Airflow Monitor The Guardian Digital Airflow Monitor P N 9743201 and 9743205 or Guardian Jr Airflow Monitor P N 9743202 and 9743206 allows you to continuously monitor face velocity through the fume hood opening The fume hood right corner post is factory prepared to mount either monitor Contact Labconco Customer Service to order Installing Guardian Digital 36 Product Service 1 800 522 7658 Chapter 7 Modifying Your Fiberglass 30 Fume Hood Figure 7 4 Figure 7 5 Installing an Electrical Duplex Receptacle If you ordered your hood and want an electrical duplex outlet then you can have one installed in the field by a qualified electrician Contact Labconco Customer Service for ord
55. ices after installation All hoods are factory prepared for up to 3 service fixtures Field installed by removing side access panel Removable side access panel for servicing valves and electrical connections All hoods are factory prepared for one electrical duplex A duplex can be field mounted on the right corner post Receptacles are field wired to the single point junction box Shipped fully assembled and eliminates the need for costly onsite assembly Product Service 1 800 522 7658 Chapter 4 Performance Features and Safety Precautions 14 Accessory Guardian Digital Airflow Monitor or Guardian Jr Monitor continuously monitors face velocity An audio visual alarm alerts the user to low airflow conditions The right corner post is factory prepared to accommodate the Guardian Monitor sold separately 15 Frame of epoxy coated steel and aluminum is durable and corrosion resistant 16 Exhaust connection The hood features 6 6 625 OD pipe exhaust connections sized to allow for a minimum static pressure loss through the hood structure while providing a good transport velocity through the exhaust system 17 Single point junction box provides a single connection point for electrical wiring connections 18 Convenient integral blower motor is readily accessible on integral blower models Product Service 1 800 522 7658 21 Chapter 4 Performance Features and Safety Precautions 22 Pro
56. ile Tracer gas release 4 liters per minute e Rated As Manufactured AM As Installed Al and As Used AU American Society of Heating Refrigerating and Air Conditioning Engineers 1791 Tullie Circle N E Atlanta GA 30329 404 636 8400 ANSI Z9 5 1993 Laboratory Standard Covers entire laboratory ventilation system e Vertical stack discharge 2000 3000 fpm e New and remodeled hoods shall have a monitoring device e Ductless hoods should only be used with non hazardous materials e Fume hood face velocities between 80 120 fpm American Industrial Hygiene Association 2700 Prosperity Avenue Suite 250 Fairfax VA 22031 703 849 8888 SEFA 1 2002 e Fume hood face velocities based on toxicity levels of chemicals Class A 125 to 150 fpm Class B 80 to100 fpm Class C 75 to 80 fpm e Test method face velocity profile and smoke generation Scientific Equipment amp Furniture Association 1028 Duchess Drive McLean VA 22102 703 538 6007 NFPA 45 2002 Fire Protection for Laboratories Using Chemicals e Laboratory hoods should not be relied on for explosion protection e Exhaust air from fume hoods should not be recirculated e Services should be external to the hood e Canopy hoods only for non hazardous applications e Materials of construction should have flame spread of 25 or less e 80to 120 fpm to prevent escape 58 Product Service 1 800 522 7658 Appendix D References N
57. in materials and workmanship ETI Exdusive feature P Features amp Benefits Automatic liquid detergent dispenser When programmed to dispense from 1 to 40 milliliters a peristaltic pump automatically draws LabSolutions Low Foaming Liquid Detergent or other auto matic washer liquid detergent from a 3 8 liter bottle during the wash cycle 360 rotating lower wash arm and spindle rack Distribute up to 60 gallons 227 liters of water per minute r Steam generator Produces hot vapor to penetrate and soften dried residue allowing detergent and hot water to work effectivwo o Quiet energy efficient operation at 62 decibels Aluminum backed sound deadening insula tion and fiberglass blanket absorb noise optimize internal tank temperature and conserve energy Powder epoxy sealed hard board top Repels moisture It may be removed for under counter installation Manual dispenser for neutraliz ing rinse solution If the auto matic liquid detergent dispenser is programmed to 0 milliliter then the neutralizing rinse solu tion dispenser in the door is activated The dispenser holds approximately 170 milliliters enough for 40 or more cycles FlasicScrubber Vantage Series Laboratory Glassware Washers Attractive Type 304 brushed stainless steel doors and sides The back is epoxy coated steel Mirror bright Type 304 stainless steel interior Provides a co
58. ins the organization of the manual and defines the typographical conventions used in the manual Chapter 2 Prerequisites explains what you need to do to prepare your site before you install your laboratory fume hood Electrical and service requirements are discussed Chapter 3 Getting Started contains the information you need to properly unpack inspect install and certify your laboratory fume hood Chapter 4 Performance Features and Safety Precautions explains how the laboratory fume hood operates and the appropriate precautions you should take when using the fume hood Chapter 5 Using Your Fiberglass 30 discusses the basic operation of your fume hood Information on how to prepare use and shut down your fume hood is included Chapter 6 Maintaining Your Fiberglass 30 explains how to perform routine maintenance on your fume hood Chapter 7 Modifving Your Fiberglass 30 explains how to modify the fume hood or add accessories Chapter 8 Troubleshooting contains a table of problems you may encounter while using your laboratory fume hood including the probable causes and suggested corrective actions Product Service 1 800 522 7658 Chapter 1 Introduction Appendix A Fiberglass 30 Hood Components contains labeled diagrams of all of the components of the fume hoods Appendix B Fiberglass 30 Hood Dimensions contains comprehensive diagrams showing all of the dimensions for the laboratory fume hoods App
59. istaltic pump and 1 liter bottle Rinse aid sample is included e Manual detergent dispenser for powder or liquid detergent Activated only when the automatic liquid detergent dispenser is programmed for 0 milliliter Detergent samples are included e Manual rinse dispenser activated only when the automatic liquid deter gent dispenser is programmed for 0 milliliter Rinse sample is included e Pump with 1 3 hp motor to redrculate up to 60 gallons 227 liters of water per minute at 60 Hz throughout the tank during wash cyde e One piece stainless steel fine mesh particle filter e Purified water pump to bring pressurized or non pressurized purified water into the tank for the last two rinses e 2000 watt heater with thermostat to boost interior temperature to a sanitizing nominal 180 F 82 C during final wash and rinse cycles for GLASS PLUS SCIENCE USER 1 SET and USER 2 SET programs Spindle rack 20 9 w x 20 dx 11 6 h 53 x 51 x 35 cm of Type 304 stainless steel Indudes 34 detach able spindles 24 each tall 8 4 x 25 OD and 10 each small 4 5 x 125 OD 24 large height adjustment dips 10 small height adjustment dips 14 nylon plugs two 4 inch Glassware Holders 4424600 and two 6 inch Glassware Holders 4424800 Steam generator that produces hot vapor before the WASH 2 cyde RINSE ONLY and PLASTIC excluded e Forced air drying system with built in blower e R2 232 port for connection to user su
60. lobe 150W 264 0006 9909 8E 1 4850000 Wiring Harness Light 8F 1 1279700 Gasket Base 8G 1 1279800 Gasket Globe 9A 1 1302300 Switch Rocker 9B 1 1327500 Switch Plug Fills cutout without switch 10A 1 2834400 Wiring Harness Main 115V 10B 1 2834500 Wiring Harness Main 230V 11 1 2834000 Label Set Corner Post 12 1 2834100 Label Front Panel 13 1 2831400 Front Panel 14A 1 2833000 Motor Plate 115V only 14B 1 2831700 Motor Plate 230V 115V EP 230V EP ISA 1 2807100 Motor 115V 15B 1 1203600 Motor 230V 15C 1 1200400 Motor 115 VEP 15D 1 1211000 Motor 230V EP 15E 1 1852300 Reducing Bushing 230V only 15F 4 1662600 Rubber Grommet 115V only 16A 1 1450000 Wheel Blower 115V only 16B 1 4716200 Wheel Blower 230V 115V EP 230V EP 17 1 2833400 Removable Side Panel Right 18 1 2831900 Side Panel Right 19 1 2832000 Side Panel Left 20 1 2832500 Sash Glass Assembly 21 1 2833800 Sash Weight 22A 1 1861400 Pulley 1 3 16 Dia 22B 1 3627500 Thrust Washer 23 2 4949902 Cable Sash 24 4 1920100 Clamp Cable Replacement 25 2 1972100 S Hook 26 1 2831500 Air Foil 27 2 1934300 Air Foil Spacer Stop 28 2 9713300 Rubber Bumper Sash Handle 29A 1 2833500 Bracket Cable Front Right 29B 1 2833501 Bracket Cable Front Left 29C 1 1663200 Rubber Bumper Upper Sash Stop 30 1 2831100 Corner Post Right 31 1 2831200 Corner Post Left 32 1 2831300 Header 30 1 9724500 Sash Stop Kit 31 1 1663200 Upper Sash Bu
61. mper 32 1 2831300 Header 44 Product Service 1 800 522 7658 Appendix A Fiberglass 30 Components Figure A 1 16 Not Shown 21 Not Shown SS 24 Not Shown ne 25 Not Shown a 8 Not Shown a 7E for Air Monitor i 1 through 6 Not Shown 27 Not shown 10 Not shown Product Service 1 800 522 7658 45 Appendix A Fiberglass 30 Components 46 Product Service 1 800 522 7658 APPENDIX B FIBERGLASS 30 HOOD DIMENSIONS iig INTEGRAL BLOWER 20 HOO DIMENSIONS MODEL 3030000 15W DIMENSION IN INCHES Figure B 1 Product Service 1 800 522 7658 47 Appendix B Fiberglass 30 Hood Dimensions DIMENSION IN INCHES 230v integral Blower 30 HOOD DIMENSIONS Figure B 2 48 Product Service 1 800 522 7658 Appendix B Fiberglass 30 Hood Dimensions DIMENSION IN INCHES REMOTE 30 HOOD DIMENSIONS MODEL 3030002 15W MODEL 3030003 230 Figure B 3 Product Service 1 800 522 7658 49 Appendix B Fiberglass 30 Hood Dimensions DIMENSION IN INCHES EP 30 HOOD DIMENSIONS MODEL 3030004 1154 MODEL 3030005 230 Figure B 4 50 Product Service 1 800 522 7658 Appendix B Fiberglass 30 Hood Dimensions i Figure B 5 51 Product Service 1 800 522 7658 Appendix B Fiberglass 30 Hood Dimensions 52 Product Service 1 800 522 7658 APPENDIX C FIBERGLASS 30 Fume Hoop SPECIFICATIONS Environmental Conditions e Ind
62. nd This statement may be altered by a specific published amendment No individual has authorization to alter the provisions of this warranty policy or its amendments Lamps and filters are not covered by this warranty Damage due to corrosion or accidental breakage is also not covered Limitation of Liability The disposal and or emission of substances used in connection with this equipment may be governed by various federal state or local regulations All users of this equipment are required to become familiar with any regulations that apply in the user s area concerning the dumping of waste materials in or upon water land or air and to comply with such regulations Labconco Corporation is held harmless with respect to user s compliance with such regulations Contacting Labconco Corporation If you have questions that are not addressed in this manual or if you need technical rs assistance contact Labconco s Customer Service Department or Labconco s Product Service Department at 1 800 821 5525 or 1 816 333 8811 between the hours of 7 00 a m and 6 00 p m Central Standard Time Visit Labconco s web site at http www labconco com or email Labconco at labconco labconco com Part 2831600 Rev A ECO C277 Product designs are subject to change without notice 2003 Labconco Corporation Printed in U S A TABLE OF CONTENTS CHAPTER 1 INTRODUCTION About This Manual Typographical Conventions Your Next Step CHAPTER 2 PR
63. nd understood by the user Your Next Step If your Fume Hood needs to be installed proceed to Chapter 2 Prerequisites to ensure your installation site meets all of the requirements Then go to Chapter 3 Getting Started for instructions on how to install your laboratory fume hood and make all of the necessary connections If you would like to review how laboratory fume hoods operate go to Chapter 4 Performance Features and Safety Precautions For information on the operational characteristics of your laboratory fume hood go to Chapter 5 Using Your Fiberglass 30 Hood If your laboratory fume hood is installed and you need to perform routine maintenance on the cabinet proceed to Chapter 6 Maintaining Your Fiberglass 30 Hood For information on making modifications to the configuration of your fume hood go to Chapter 7 Modifving Your Fiberglass 30 Fume Hood Refer to Chapter 8 Troubleshooting if you are experiencing problems with your fume hood Product Service 1 800 522 7658 CHAPTER 2 PREREQUISITES Before you install your laboratory fume hood you need to prepare your site for installation Carefully examine the location where you intend to install your hood You must be certain that the area is level and of solid construction In addition a dedicated source of electrical power must be located near the installation site Carefully read this chapter to learn the requirements for your installation site
64. ndividual version of this declaration is included with your shipping customs document Labconco PT 36900 39 REV ECO B99 Product Service 1 800 522 7658 61
65. ndow allows observation of the cycle in progress A 25 watt interior light illuminates the tank while the door latch is engaged Sanitizing high heat Higher temperature loosens stubborn lipid based residues for cleaner sanitized glassware Models for operation on 230 volts 50 60 Hz include a high heat option A 2000 watt heater and thermostat allow interior temperatures to reach a nominal 180 F 82 C with a minimum inlet temper ature of 120 F 49 C during the second wash and rinse cycle High heat is automatically activated when GLASS PLUS SCIENCE or USER 2 SET is selected Spray Patterns Basic Spray Pattern Inset Vacuum Drying System Spray Pattern with Accessory Upper Spindle Rack and Hub Adapter See page 26 for Upper Spindle Rack ordering information Spray Pattern with Accessory Adjustable Height Upper Rack and Hub Adapter See page 26 for Adjustable Haight U pper Rak ordering information Interior Dimensions Le 21 5 gt FRONT 24 m 21 5 gt FRONT SIDE with Upper Spindle Rack a FlaskScrubb ers General Specifications All models feature e Type 304 mirror finish stainless steel tank wash arm and tower e Type 304 brushed stainless steel door e Two rows of polypropylene rollers in tank for accessory upper rack e Fiberglass blanket and aluminum backed a
66. ne particles protecting the pump from broken glass and debris 18 Steam generator Produces hot vapor to penetrate and soften dried residue allowing detergent and hot water to work effectively Attractive Type 304 brushed stainless steel door Mobile and free standing models also have brushed stainless steel sides and epoxy coated steel backs Quiet energy efficient operation at 62 decibels Aluminum backed sound deadening insula tion and fiberglass blanket absorb noise optimize internal tank temperature and conserve energy Stainless steel top and bottom racks Accommodate a variety of accessory inserts and the broadest range of glassware Two rows of rollers on the sides of the washer s interior guide the top rack and allow place ment of the rack in two positions to accommodate various glassware heights See pages 26 and 27 for insert selection Dispenser for neutralizing solution Allows addition of mildly acidic rinse aid to alter pH and eliminate alkaline detergent carry over Draw latch Securely locks the door while energizing the electronic controls Built in heater Boosts water and glassware tem peratures to enhance washing and drying results by applying heat during all cydes Models for operation on 115 volts have 1200 watts of heat ing power 230 volt mod els have 2000 watts With a minimum inlet tempera ture of 120 F 49 C the sump
67. ned in this manual and the accompanying product is copyrighted and all rights are reserved by Labconco Corporation Labconco Corporation reserves the right to make periodic design changes without obligation to notify any person or entity of such change Fiberglass 30 Laboratory Fume Hood Manual 28316 Warranty Labconco provides a warranty on all parts and factory workmanship The warranty includes areas of defective material and workmanship provided such defect results from normal and proper use of the equipment The warranty for all Labconco products will expire one year from date of installation or two years from date of shipment from Labconco whichever is sooner except the following e Purificr Delta Series Biological Safety Cabinets carry a three year warranty from date of installation or four years from date of shipment from Labconco whichever is sooner e Carts carry a lifetime warranty e Glass is not warranted from breakage due to accident or mishandling This limited warranty covers parts and labor but not transportation and insurance charges In the event of a warranty claim contact Labconco Corporation or the dealer who sold you the product If the cause is determined to be a manufacturing fault the dealer or Labconco Corporation will repair or replace all defective parts to restore the unit to operation Under no circumstances shall Labconco Corporation be liable for indirect consequential or special damages of any ki
68. nnecting the hood from electrical service Proper operation of the fume hood depends largely upon the hood s location and the operator s work habits Consult the Reference Manual in Appendix D Your Next Step After you understand the theory of operation and safety precautions you are ready to proceed to Chapter 5 Using Your Fiberglass 30 Fume Hood Product Service 1 800 522 7658 25 Chapter 4 Performance Features and Safety Precautions Product Service 1 800 522 7658 CHAPTER 5 Usinc Your FIBERGLASS 30 Fume Hoop Operating the Vertical Rising Sash Because of the Fiberglass 30 Hood counterbalanced sash mechanism it will take only a few pounds of force to move the sash up or down and you can operate the sash smoothly with one or two hands positioned any where along the handle The vertical rising sash may be raised to a maximum 20 operating height The airflow requirements should be sized for the 20 operating height Product Service 1 800 522 7658 27 Chapter 5 Using Your Fiberglass 30 Fume Hood 28 Operating the Blovver Your Fiberglass 30 Fume Hood utilizes a remote style blower or integral blower which can be activated by turning the blower switch to ON You can validate the hood performance by watching smoke drawn into the hood face opening Explosion proof models do not have a switch or wiring as this is field installed Operating the Lights Your Fiberglass 30 Fume Hood is
69. nstruction Rugged stainless steel construction inside and out withstands heavy use and reduces corrosion and contaminant build up Interior View Viewing window with interior light lets you see each cycle in progress This feature which is optional on FlaskScrubber and SteamScrubber Glassware Washers and standard on FlaskScrubber Vantage Series Glassware Washers gives at a glance assurance of your vvasher s performance Adjustable Base Stand Base stand elevates the washer 17 for easier loading and unload ing This optional stand has a convenient compartment for storing detergent and other accessories FlasiScrubbers amp SteamScrubbers Overview Seled the Labconco glassware washer that best suits your glassware mix and leva of contamination sensitive research The FlaskScrubber is designed for primarily narrow neck glassware such as volumetric flasks The bottom spindle rack included with the washer holds up to 34 pieces of labware and may be outfitted with specialized inserts to accommo date pipets Water and detergent are pumped through the spindles to reach the innermost areas of your glassware A patented drying system vacuums moisture from inside the glassware replacing it with hot dry air Optional basket inserts and upper racks increase the FlaseScrubber s capacity and flexibility The SteamScrubber has stainless steel top and bottom racks that accommodate basket inserts for a wide range of glassware shapes and si
70. ntage Series Washer Gray vinyl coated Type 304 stainless steel holders grip wide mouth glassware over spindles Catalog Description Shipping Weight 4424600 4 h 10 am 0 4 Ibs 0 2 kg 4424800 6 h 15 am 0 4 Ibs 0 2 kg All Washer Models Companion Products LabSolutions Liquid Detergent 4522000 Neutralizing Add Rinse 4522000 and Powder Detergent 4422100 and 4422000 LabSolutions Non Foaming Powder Detergent e Specially formulated for Labconco glassware washers e Removes most lab contaminants such as grease agar blood and protein digestates e Rinses completely e Non foaming formula does not promote leaks e Includes scoop for accurate measurement e Economical Most cyde programs require just one scoop A 1 solution has a pH of approximately 12 5 e Non hazardous formula may be shipped anywhere Catalog Description Shipping Weight 4422000 Powder Detergent small pail 10 Ibs 4 5 kg for approximately 140 loads 4422100 Powder Detergent large pail 27 5 lbs 12 5 kg for approximately 400 loads LabSolutions Low Foaming Liquid Detergent e Specially formulated for Labconco glassware washers Dispenses automatically in FlaskScrubber Vantage Series Washers e Removes a wide range of laboratory contaminants e Rinses completely e Non corrosive formula won t degrade stainless steel glass or plastic e Phosphate free for environmentally safe disposal e Chlorine free and tissue culture safe
71. oor use only e Maximum altitude 6562 feet 2000 meters e Ambient temperature range 41 to 104 F 5 to 40 C e Maximum relative humidity 80 for temperatures up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C e Main supply voltage fluctuations not to exceed 10 of the nominal voltage e Transient over voltages according to Installation Categories II Over voltage Categories per IEC 1010 Temporary voltage spikes on the AC input line that may be as high as 1500V for 115V models and 2500V for 230V models are allowed e Used in an environment of Pollution degrees 2 i e where normally only non conductive atmospheres are present Occasionally however a temporary conductivity caused by condensation must be expected in accordance with IEC 664 Product Service 1 800 522 7658 53 Appendix C Fiberglass 30 Hood Specifications MOROS ETC I ee dm eT COBETIE CHF TOR MALIH IMOd 319456 i Poe WEES eid dE 1 LI iT hi Jit QHD M RI g3 M 34 WOLTWINOS HO MOTTE 107 L i a PC alana des NAS CORRE Afd TH Gace MAIS SE SO00H 0191i 4d DONODEVT IH DMA MAS Gl 40H TAan0S Made moas Loong JNINSY M Product Service 1 800 522 7658 54 Appendix C Fiberglass 30 Hood Specifications STROSS TT Te aD OA gjan KOS MOLLIWNP LMOd TRE OH HI Zan ET M W LFS WI KMS LA SURE LATE a a Sed be JE WAG GEE Hid EH Gnas Matt eut OE SO00H H515310Hd MAO IQ ONIHM
72. or 60 minute Dry time Add 2 9 gallons 11 liters for each additional rinse 11 User 1 Set User 2 Set Standard High 5 5 t 107 10 10 2 2 4 20 PR PR Xk xk PR RR Xk xk 10iii 10 44 to 186 68 to 207 10 gallons 10 gallons 37 9 liters 37 9 liters Bold numbers indicate preset times INCLUDES Spindle rack with 34 detachable spindles with height adjustment clips Large volumes of water stream into the bulb of each flask for high powered cleaning Clips may be raised and low ered on the 24 tall spindles to accommodate flasks from 50 ml to 2000 ml The 10 small spindles hold flasks from 1 ml to 25 ml Spindles detach easily to customize rack for acces sory inserts sold sepa rately See pages 26 and 27 for insert selection Adjustable Glassware Holders Secure Erlenmeyer flasks and beakers over the spindles The vinyl coated fingers gently cradle the glass ware Two 4 inch and two 6 inch Glassware Holders are included ETL listed Washers carry the ETL mark signifying they are certified to UL Standard 3101 1 and CAN CSA C22 2 No 1010 1 CE Mark Washers conform to the CE European Community requirements for electrical safety and electromagnetic compatibility FifekscriQbers Features amp Benefits Patented vacuum drying system Draws moisture from inside the flasks replacing it with hot dry air Melamine covered high density partide board top Rep
73. ork surface is aligned with the back of the fume hood This will provide the correct spacing under the air foil for proper bypass airflow WARNING It is important to support the rear of the work surface and fume hood The cross support provides support for the bottom of the work surface Install the cross support after the base cabinets and work surface are leveled and before installing the hood The following are instructions for mounting a cross support 1 Level the base cabinets and the work surface Work surface should be placed flush with the back of the fume hood as shown in Figure 3 1 2 Scribe a line on the wall or back of the base cabinet to locate the support under the work surface 3 Mount the support by attaching it to the wall or base cabinet 4 Place the hood on top of the work surface and cross support The work surface should be smooth and durable such as a chemically resistant epoxy resin The surface should be nonporous and resistant to the acids solvents and chemicals used Product Service 1 800 522 7658 Chapter 3 Getting Started BC HCCO INSTALLATION SIDE VEN Place Cross Support Here Figure 3 1 Connecting to the Fiberglass 30 Hood Exhaust System WARNING The weight of the exhaust ductwork system must be supported independently of the hood superstructure Do not allow this weight to be supported by the hood structure as damage to the hood may occur Product Servic
74. pid Guide to Hazardous Chemicals in the Workplace Van Nostrand Reinhold 1987 Product Service 1 800 522 7658 59 Appendix D References Schilt Alfred A Perchloric Acid and Perchlorates The G Frederick Smith Chemical Company Columbus OH 1979 Steere Norman CRC Handbook of Laboratory Safety 2 Edition CRC Press 1971 60 Product Service 1 800 522 7658 DECLARATION OF CONFORMITY Applicaton Council Directivelsi 73 23 EEC 80 336 EEC Stundardist to which conformity ig declared ENGIO LO ENS3002 EN S0082 Manufacturer s Name Labconeo Corporation Mamutactuner s Address BEL Prospect Avenue Kansas Civ MO 64192 USA Importer s Name See Shipping Customs Documents Importers Address See Shipping Customs Documents for your equipment Type of Equipment Laboratory Equipment Fume Hoods Cabinets Model No Fiberglass Mi Fume Hood HUW Pibergless HI Laboratory Howls MADHI Fiberglass Hi Laboratory Hoods MUNIE Fiberglas 40 Laboratory Hoods VOM Fiberglass 30 Laboratory Hoods MOQUE Fiberglics H0 Laborasory Hoods JOVES Fiberglass 10 Labortory Hondi Serul Nos Various See Individual Declaration Year of Manufacture MIS amb subsequent L the undersigned hereby declare that the equipment specified abowe conformes to the above Directives and Stundardis See individual Declaration of Conformity which will be signed by the importer for your country Signature Full Name Position An i
75. pplied computer or recorder e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 cm e 25 watt interior light that remains lit while the door latch is engaged e Purified water inlet valve with a plastic serrated connector to accommo date a 3 8 ID flexible plastic or rubber hose hose not included e 2 year warranty on parts and labor All models conform to the following e UL 3101 1 61010 1 e CAN CSA C22 2 No 1010 1 e CE Conformity Marking 230 volt models All models require not included e Minimum inlet water temperature of 50 F 10 C e Recommended inlet water temperature of 120 F 49 C e Minimum inlet water pressure of 20 psi e Maximum inlet water pressure of 120 psi e Minimum purified water pressure of 0 psi e Water consumption per fill of 2 9 gallons 11 liters e Hot tap water pressure at the washer of 20 120 psi e Hot tap water flow of 1 25 gallons 4 7 liters per minute e 3 8 ID copper tubing or flexible hose for connection to the water inlet valve e Purified water with supply piping of a minimum 3 8 ID to permit at least 1 25 gallons 4 7 liters per minute flow e Hard wiring to a 20 amp dedicated circuit e Drain air gap e Drain tubing or pipe 1 2 1 3 cm diameter or larger Optional companion products and accessories include e Base Stand See page 26 e Adjustable Height Upper Rack See page 26 e Upper Spindle Rack See page 26 e Pipet Inse
76. pter 8 Troubleshooting PROBLEM Fume hood blower operates but light will not operate Contaminants outside of fume hood Vertical rising sash no longer operates smoothly CAUSE Lamp wiring is disconnected Defective lamp Improper user techniques for the fume hood Restriction of the baffle air slots or blockage of the exhaust outlet External factors are disrupting the fume hood airflow patterns or acting as a source of contamination Fume hood has improper face velocity Cable is frayed or plastic protection is damaged Pulley bearing is damaged Cable has slipped off the pulleys Weight has broken pulleys CORRECTIVE ACTION Inspect lamp wiring Replace lamp See Certifying the Hood Chapter 3 and Safety Precautions Chapter 4 sections in the manual Ref Appendix D Remove baffles to ensure that all air slots and the exhaust outlet are unobstructed See Location Requirements Chapter 2 Certifying the Hood Chapter 3 and Safety Precautions Chapter 4 sections of this manual Ref Appendix D Have fume hood re certified and check remote blower exhaust system Hood should have average face velocity of 80 100 fpm Inspect cable and replace cable if worn or damaged immediately otherwise injury could result Replace pulley bearing or add grease Re install cable must be replaced immediately if damaged Replace weight pulleys
77. qualified technicians Product Service 1 800 522 7658 31 Chapter 6 Maintaining Your Fiberglass 30 Fume Hood Routine Maintenance Schedule Weekly e Using ordinary dish soap to clean the surface inside of the fume hood and the work surface e Using an appropriate glass cleaner clean the sash and all glass surfaces e Operate the fume hood blower noting the airflow velocity through the hood using a source of visible smoke Monthly or more often as required e Determine the actual face velocity through the sash opening of the hood where the average reading should be at the specified velocity Use calibrated thermal anemometer or other approved apparatus e Using a damp cloth clean the exterior surfaces of the hood particularly the front of the hood to remove any accumulated dust e Check all service valves if so equipped for proper operation e The hood baffles should be checked for blockages behind them to ensure that the hood is maintaining proper airflow e All weekly activities Annually e Have the fume hood recertified by a qualified certification technician See Certifying the Fiberglass 30 Fume Hood in Chapter 3 e All monthly activities Biannually e The sash assembly should be checked to ensure proper operation and to make sure there are no signs of abnormal wear on the sash pulleys cables and clamps 32 Product Service 1 800 522 7658 Chapter 6 Maintaining Your Fiberglass
78. r leveling feet e 3 8 IPS inlet fitting for hot tap water connection e Factory installed drain hose and band clamp e Exterior dimensions 24 5 vv x 26 7 d x 35 1 h minimum to 37 1 h maximum 62 2 x 67 8 x 89 2 cm minimum to 94 2 cm maximum e Shipping weight 189 Ibs 86 kg All 115 volt models feature 11 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C e Operation on 115 volts 60 Hz 16 amps All 230 volt models feature 17 2000 watt heater with thermostat to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the heater elevates water temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is elected or approximately 60 F 33 C when GLASS PLUS SCIENCE or USER 2 SET is selected e Operation on 230 volts 50 60 Hz 13 amps e CE Conformity marking Models 4420410 and 4420411 feature e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 cm e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 14 e Hard wiring to a 20 amp dedicated circuit e Drain air gap e Drain tubing or pipe 1 2 1 3 cm diameter or larger
79. refully remove the shrink wrap or carton on your The United States Commission rules require that claims be fume hood and inspect it for damage that may have filed with the delivery occurred in transit If your unit is damaged notify the carrier within fifteen 15 delivery carrier immediately and retain the entire days of delivery shipment intact for inspection by the carrier Product Service 1 800 522 7658 9 Chapter 3 Getting Started 10 DO NOT RETURN GOODS VVITHOUT THE PRIOR AUTHORIZATION OF LABCONCO UNAUTHORIZED RETURNS VVILL NOT BE ACCEPTED IF YOUR HOOD WAS DAMAGED IN TRANSIT YOU MUST FILE A CLAIM DIRECTLY WITH THE FREIGHT CARRIER LABCONCO CORPORATION AND ITS DEALERS ARE NOT RESPONSIBLE FOR SHIPPING DAMAGES Do not discard the shipping skid or packing material for your fume hood until you have checked all of the components and installed and tested the unit Do not remove the fume hood from its shipping skid until it is ready to be placed into its final location Move the unit by placing a flat low dolly under the shipping skid or by using a floor jack 1 THE FIBERGLASS 30 HOOD MODELS WEIGH BETWEEN 96 TO 129 LBS 44 59 KG THE SHIPPING SKID ALLOWS FOR LIFTING WITH A MECHANICAL LIFT TRUCR OR FLOOR JACK IF YOU MUST LIFT THE FUME HOOD MANUALLY FOLLOW SAFE LIFTING GUIDELINES NORMALLY THE FUME HOOD CAN BE SLID OFF A HYDRAULIC LIFT TABLE AND BE PLACED INTO POSITION ON TOP OF THE WORK SURFACE
80. rinsing and drying With a minimum inlet temperature of 50 F 10 C the heater elevates water temperature approximately 2 5 F 1 4 C per minute to a maximum of 180 F 82 C during the final wash and final rinse cycles depend ing on the program Spray Built in forced air HEPA filtered drying system A 99 97 efficient HEPA filter traps dust lint and other particulates in the air An easily removable and cleanable prefilter traps larger dirt and debris particles before they reach the HEPA filter prolonging HEPA filter life This HEPA filtered air is blown through the spindles to ensure thoroughly clean dry glassware inside and out RS 232 port May be used to transmit data such as temperature cycle phase water level alarm water conductivity and voltage alarm to a user supplied computer ml or chart recorder Rollers on the tank interior accommodate an optional upper rack accessory sold separately The optional Upper Spindle Rack holds an additional 24 pieces of narrow neck labware Adjustable Height Upper Rack holds many types of labvvare especially beakers See page 26 for ordering information are certified to UL Standard 3101 1 and CAN CSA C22 2 use No 1010 1 CE Mark Washers conform to the CE European Community requirements for electrical safety and electromagnetic compatibility D ETL listed Washers carry the ETL mark signifying they Patterns
81. rro Sion resistant surface that reduces contaminant carry over during wash and rinse cycles T Up to 6 pure water rinses may be programmed A built in puri fied water pump draws from a storage tank or pressurized system to deliver purified water during final rinses Particle filter One piece stain less steel screen filters fine parti des protecting the pump from broken glass and debris E Madein the U S A FlasicScrubber Vantage Series Laboratory Glassware Washers Features amp Benefits Adjustable Glassware Holders Secure Erlenmeyer flasks and beakers over the spindles The vinyl coated fingers gently cradle the glassware Two 4 inch and two 6 inch Glassware Holders are included Water conductivity monitoring Sensor measures the level of dissolved inorganics such as calcium and ferrous ions in the tank water provid ing validation of water cleanliness hardness and rinsing thoroughness It may be used to confirm that detergent rinse aid and purified water were properly dispensed into the water Water conductivity is displayed on the LCD and may be transmitted via the RS 232 port Viewing window with interior light The clear tempered safety glass window allows observation of the cycle in progress A 25 watt interior light illuminates the tank while the door latch is engaged Sanitizing high heat Built in 2000 watt heater and thermostat boost interior temperatures to enhance washing
82. rts See page 27 e Basket Inserts See pages 26 27 e LabSolutions Detergents and Rinse See page 28 e Laboratory Glassware Carts See page 28 e WaterPro RO Stations and Softeners See page 29 Catalog Electrical Options Number Requirements High Heat Window amp Light 4540000 230 volts 50 60 Hz 12 amps e 4540001 208 volts 50 60 Hz 14 amps e ET exdusive teture p FlaskScrubber Vantage Series Glassware Washers Dimensional Data Freestanding 49 3 35 1 min 37 1 wax FRONT SIDE Undercounter 49 0 Interior Dimensions SIDE FRONT with Upper Spindle Rack FlaskScrubbers amp SteamScrubbers Flexible Cycle Options Select from seven programs with the flexibility to change wash and dry cyde duration and number of rinses START CANCEL SELECT PROGRAM SHIFT PROGRAM WASH 1 Displays first WASH 2 Displays NUMBER OF RINSES Initiates program Selects one of seven Changes the display to wash time in minutes second wash time in Displays number of selected Terminates programs which is show parameters of the Time varies depending minutes User may rinses User may select cyde in progress shown on the display program selected on program selected select from 10 20 30 up to 6 rinses WASH 1 WASH 2 or 40 minutes NUMBER OF RINSES TOTAL WASH PURE During program selection designates purified water 2 9 gallons or 11 liters
83. ry time when parameters of the selected pro gram are displayed LCD displays selected program or details of e Minimum inlet water pressure of 20 psi e Minimum purified water pressure of 0 psi the program WASH 1 time WASH 2 time NUMBER OF e Water consumption per fill of 2 9 gallons 11 liters RINSES TOTAL WASH time and DRY time PURE button 0 selects purified water for the last two rinses STEAM button Hot tap water pressure at the washer of 20 120 psi selects steam to be added before the WASH 2 cycle Amber e Hot tap water flow of 1 25 gallons 4 7 liters per minute ee APR exe Lo PURE RO STEAM DUONG e 3 8 ID copper tubing or flexible hose for connection to the water inlet valve e Manual detergent dispenser for powder or liquid detergent Detergent samples are included e Purified water with supply piping of a minimum 3 8 ID to permit at least 1 25 gallons 4 7 liters per minute flow e Manual rinse solution dispenser Rinse sample is included e Pump with 1 3 hp motor to recirculate up to 60 gallons Optional companion products and 227 liters of water per minute at 60 Hz throughout the tank accessories include during wash cycle e Base Stand See page 26 e One piece stainless steel fine mesh particle filter e Adjustable Height Upper Rack See page 26 e Purified water pump to bring pressurized or non pressurized e Basket Inserts See pages 26 27 purified water into the tank for the last two rinses e LabSolu
84. s Accessory Upper Spindle Rack 4525000 with spindles removed and plugged Utensil Holder 4542500 For spatulas spoons scoops and other miscellaneous utensils Utensils fit vertically in four com partments 2 75 w x 3 5 d x 4 88 h 7 x 8 9 x 12 4 cm Type 304 stainless steel Dimensions a 10 75 w x 4 13 d x 6 63 h 27 3 x 10 5 x 16 8 cm Shipping weight 3 5 Ibs 1 6 kg Re Utensil Basket 4402201 For miscellaneous labware such as stoppers spatulas and other small lightweight items that will not pass through No 4 mesh sides and bottom Retainer top is required and included Type 304 stainless steel Dimensions 8 0 w h 20 3 x 20 3 x 10 2 cm Shipping weight 1 5 Ibs 0 7 kg x 8 0 dx 4 0 Four Utensil Holders maximum in FlaskScrubber and FlastSarubber Vantage Series Washers 26 All Washer Models Accessories Bulk Tube Insert 4542100 Quick loading For vertically posi tioned test tubes Holds up to 600 each 13 mm tubes or 244 each 20 mm tubes Bottom grate size 38 9 5 mm allows water to drain from inverted tubes When insert is less than fully loaded the divider may be adjusted to keep tubes upright Type 304 stainless steel Smallest divided compartment size 1 75 w x 8 13 d x 4 18 h 4 4 x 20 7 x 10 6 cm Overall interior dimensions without divider 18 69 w x 8 13 d x 4 18 h 47 5 x 20 7 x 10 6 cm Dimensions 21 w x 8 25 dx 4 38 h 53 3 x 20 7 x 11 1 am Shipping weight
85. s 30 Hood with Integral Blower 100 fpm 310 cfm capable of overcoming 0 12 external static pressure Fiberglass 30 Hood for use with Remote Blower 100 fpm 310 cfm 0 14 static pressure loss Fiberglass 30 Hood with Explosion Proof Blower 100 fpm 310 cfm capable of overcoming 0 12 external static pressure Proper blower selection can be determined from these exhaust requirements and the total system static pressure loss Contact Labconco Customer Service for assistance in sizing a blower Product Service 1 800 522 7658 Chapter 2 Prerequisites Electrical Requirements Other than explosion proof models the Fiberglass 30 Hood models feature internal wiring for the incandescent light assembly light switch and blower switch If your unit has an integral blower then internal wiring to the blower motor and blower switch is included Explosion Proof blowers require on site wiring All internal wiring is terminated at the single point wiring junction box for hook up by a qualified electrician Refer to Chapter 3 Getting Started and Appendix C Fiberglass 30 Specifications for the wiring diagram for proper electrical installation Service Line Requirements All service lines to the laboratory fume hood should be Ys inch outside diameter copper brass for natural gas and equipped with an easily accessible shut off valve should disconnection be required If the service line pressure exceeds 40 PSI it must be equipped with
86. sing techniques or procedures that disrupt the airflow patterns of the hood Final Purging e Upon completion of work the hood should be allowed to operate for two to three minutes undisturbed to purge airborne contaminants from the work area before shutting down blower Unloading Materials and Equipment e Objects in contact with contaminated material should be surface decontaminated before removal from the hood e All open trays or containers should be covered before being removed from the hood Shutdown e Turn off the incandescent light and hood blower and then close the sash Your Next Step After you understand how to operate and work in the fume hood you are ready to proceed to Chapter 6 Maintaining Your Fiberglass 30 Fume Hood Product Service 1 800 522 7658 29 Chapter 5 Using Your Fiberglass 30 Fume Hood 30 Product Service 1 800 522 7658 CHAPTER 6 MAINTAINING YOUR FIBERGLASS 30 Fume Hoop Now that you have an understanding of how to work in the fume hood we will review the suggested maintenance schedule and the common service operations necessary to maintain your fume hood for peak performance Only trained and experienced certification technicians should perform some of the service operations after the fume hood has been properly decontaminated DO NOT attempt to perform these operations if you are not properly trained The wrench icon precedes the service operations that require
87. tions Detergents and Rinse See page 28 e Laboratory Glassware Carts See page 28 e WaterPro RO Stations and Softeners See page 29 lExdusve feature 20 SteamScrubber Undercounter Glassware Washers Specifications amp Ordering Information All undercounter models feature e General specifications described on page 20 e Four leveling feet e 3 8 IPS inlet fitting for hot tap water connection e Factory installed drain hose and band clamp e Exterior dimensions 24 0 vv x 26 4 d x 34 3 h minimum to 36 3 h maximum 60 9 x 67 1 x 87 1 cm minimum to 92 1 cm maximum e Shipping weight 142 Ibs 64 kg All 115 volt models feature 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C e Operation on 115 volts 60 Hz 16 amps All 230 volt models feature 2000 watt heater with thermostat to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the heater elevates water temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is selected or approximately 60 F 33 C when GLASS PLUS SCIENCE or USER 2 SET is selected e Operation on 230 volts 50 60 Hz 13 amps e CE Conformity marking Models 4400310 and 4400311 feature
88. to change the airflow at the sash opening of your hood To determine the actual face velocity at the sash opening airflow velocity readings will need to be taken This should be done across the sash opening of the hood in accordance with the Industrial Ventilation Manual section on laboratory hoods See Appendix D Reference Labconco recommends an average face velocity at the sash opening of 80 to 100 feet per minute Consult Chapter 2 for proper airflow volumes for your particular model The Fiberglass 30 Fume Hood has been tested per ASHRAE 110 1995 All hoods achieve an as manufactured rating of less than 0 10 part per million ppm at 4 liters per minute lpm AM lt 0 10 consult Labconco for individual fume hood ratings For field use ASHRAE testing by a certified technician contact Labconco Customer Service Product Service 1 800 522 7658 17 Chapter 3 Getting Started 18 NOTE Face velocity profiles and smoke testing should be done periodically to ensure safe performance Your Next Step After your fume hood has been installed and certified you are ready to proceed to Chapter 4 Performance Features and Safety Precautions Product Service 1 800 522 7658 CHAPTER 4 PERFORMANCE FEATURES AND SAFETY PRECAUTIONS Performance Features The Fiberglass 30 Laboratory Hood is designed to meet the needs of the laboratory scientist A fully featured by pass hood with baffle and air foil can
89. volts 60 Hz 16 amps All 230 volt models feature 1 2000 watt heater with thermostat to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the heater elevates water temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is selected or approximately 60 F 33 C when GLASS PLUS SCIENCE or USER 2 SET is selected e Operation on 230 volts 50 60 Hz 13 amps e CE Conformity marking Models 4420310 and 4420311 feature e Clear tempered safety glass window 6 3 w x 13 8 h 15 9 x 34 9 am e 25 watt interior light that remains lit while the door latch is engaged All models require not included e Requirements described on page 14 e Hard wiring to a 20 amp dedicated circuit e Drain air gap e Drain tubing or pipe 1 2 1 3 cm diameter or larger ESlexdusve feature Catalog Electrical pt Number Requirements Options High Heat Window amp Light 4420300 115 volts 60 Hz 16 amps 4420301 230 volts 50 60 Hz 13 amps 4420310 115 volts 60 Hz 16 amps 4420311 230 volts 50 60 Hz 13 amps 15 ml FlaskScrubber Freestanding Glassware Washers Specifications amp Ordering Information All freestanding models feature e General specifications described on page 14 e Black melamine covered high density particle board top e Type 304 stainless steel sides e Epoxy coated steel back e Fou
90. xy coated steel back e Four 2 inch diameter rubber casters e Quick disconnect attachment for inlet water and drain on top of washer e Two aerator adapters for connection to standard 55 64 27 male and 15 16 27 female laboratory faucets e Exterior dimensions 24 5 w x 26 7 dx 37 0 h 62 2 x 67 8 x 93 8 cm e Shipping weight 189 Ibs 86 kg All 115 volt models feature 17 1200 watt heater to boost water and glassware temperatures during washing and drying With a minimum inlet temperature of 120 F 49 C the sump heater elevates water temperature approximately 20 F 11 C e 5 4 163 cm grounded power cord with 20 amp plug e Operation on 115 volts 60 Hz 16 amps All 230 volt models feature 112000 watt heater with thermostat to boost water and glassware Catalog Electrical Options temperatures during washing and drying With a minimum Number Requirements High Heat Window amp Light inlet temperature of 120 F 49 C the heater elevates water 4400000 115 volts 60 Hz 16 amps temperature approximately 20 F 11 C when PLASTIC GLASS or USER 1 SET is selected or approximately 60 F 33 C 0000 230 volts 50 60 Hz Bamps when GLASS PLUS SCIENCE or USER 2 SET is selected 4400010 115 volts 60 Hz 16 amps e 5 4 163 cm grounded power cord A 20 amp plug is required 4400011 230 volts 50 60 Hz 13 amps z e Operation on 230 volts 50 60 Hz 13 amps
91. ycle in progress SELECT PRO GRAM button allows selection of the program DATA button scrolls through displays of water temperature water conductivity and any faults low detergent low rinse agent low fill low voltage high volt age low water temperature and defective float switch SELECT but ton activates the display to show parameters of the program selected STEAM WASH 1 time WASH 2 time the NUMBER of RINSES the NUMBER of PURE RINSES TOTAL WASH time excluding the time required to heat the inlet water and DRY TIME Parameter up down change buttons modify set points for changeable parameters WASH 2 time WASH 2 temperature detergent dispense number of rinses number of pure rinses last rinse temperature rinse aid dispense dry time LCD displays program selected RINSE ONLY PLASTIC GLASS GLASS PLUS SCIENCE USER 1 SET USER 2 SET steam selection time in minutes for WASH 1 and WASH 2 number of RINSES and PURE RINSES time in minutes for TOTAL WASH and DRY or set points for user programmable parameters ENTER button stores modi fied parameters into memory FACTORY RESET button restores the preset parameters Red light flashes when fault s are detected low detergent low rinse agent low fill low voltage high voltage low water temperature or defective float switch e Automatic liquid detergent dispenser with peristaltic pump and 3 8 liter bottle Detergent sample is induded e Automatic rinse aid dispenser with per
92. zes primarily beakers and other wide mouth glassware Specialized inserts for BOD bottles petri dishes culture tubes small utensils and DNA sequencing plates enhance the SteamScrubber s versatility The new FlaskScrubber Vantage Series Glassware Washer has many of the fea tures of the FlaskScrubber such as the 34 spindle rack plus advanced elements that safeguard glassware used in contamination sensitive research Temperature up to 180 F 82 C may be programmed for wash and rinse cycles to remove lipids and sanitize glassware Up to six purified water rinses may be programmed to ensure that no water soluble contaminants are introduced The water conduc tivity sensor measures the level of dissolved inorganics in the tank to validate water cleanliness hardness and rinse thoroughness The forced air drying system incorporates a 99 97 efficient HEPA filter to remove airborne particulates The RS 232 port provides a means to document settings and actual washing conditions These advanced features work together to deliver thoroughly clean dry labware FlasicScrubber Vantage Series Laboratory Glassware Washers Flexible Cycle Options Select from seven programs with the flexibility to change multiple parameters SELECT PROGRAM STEAM Displays Y WASH L Displays first WASH 2 Displays NUMBER OF RINSES NUMBER OF PURE Selects one of seven for yes or N for no wash time either 0 or 5 secon
Download Pdf Manuals
Related Search
Related Contents
RCA TV/Radio/CD Player CD Player User Manual 0322mu2029-2010-0a MCE2029 Standard Manual UK PDF DeLOCK 41776 slot expander Philips SPP6020B Samsung ME71A/AND User Manual ハンディキャリブレータ CA71 用 CA71 アプリケーション 取扱説明書 Remote Wireless Copyright © All rights reserved.
Failed to retrieve file