Beam 230W Hybrid - Omikron Pro Lighting
Contents
1. 10 Gobo wheel 000 255 11 Gobo effect 000 255 12 Prism macros 000 255 13 Prism rotation 000 255 14 Focus 000 255 15 Focus fine 000 255 16 Frost 000 255 17 Exit When connected with a DMX controller the channel value can not be changed only show channel DMX value While there is no DMX controllers you can control the fixture by this item select some channel roll the encoder wheel to adjust DMX value 09 Display 1 Lnguage English Chinese or some other language according to your requirement 2 Backlight time Open always on 30 seconds 3 Back brightness 1 4 from dark to bright 4 Exit 10 Motor adjust 01 Strobe 31 31 02 Pan 31 31 03 Tilt 31 31 04 Color 31 31 05 Gobo 31 31 06 Prism 31 31 07 Prism rotation 31 31 08 Focus 31 31 09 Frost 31 31 10 Motor zero password Can be set password afterwards to prevent unwanted modifying 11 Save password Can be set password afterwards to prevent unwanted modifying 12 Exit 11 Control 01 Control select DMX Auto Music Slave These function have not been finished now they would be finished 6 8 afterward according to your suggestion 02 Auto run program 1 9 Select the program you want to run in certain mode 03 Auto run speed 1 16 Set running speed for program 04 Exit 13 Help info Include copyright company information etc 14 Exit 11 D
2. Be sure to connect the product exclusively to AC110 127V 59 60Hz Always insure during installation operation transport and when storing the product that the mains cord is not exposed to possible mechanical damage or damage caused by humidity fluids heat or cold The products cable entry must not be exposed to stress from pull Create the mains connection once the product has been installed only Always connect the mains plug last The producct must only be connected to a proper outlet of the public supply grid Connect the mains cord to suitable outlets only Use entensions cords in compliance with specifications only Do not allow the mains cord to come into contact with other cords Ensure during installation operation transport and storage that none of the cables are freely exposed Never touch the mains cord mains plug and outlet with wet or damp hands When not using the product and proform to cleaning always disconnect the product from mains To do so hold the mains plug by the handling surface and never pull the mains cord Never connect the device to dimmer packer ATTENTION A DANGER OF LIFE RISKOF FIRE 3 Housing RISK OF SHORT CIRCUIT Always insure during installation operation transport and when storing the product that no shocks or other forces impact the housing The housing must not touch onto any other devices or objects during operation Easily flammable materials e g decoration material and other sur
3. electric shock Before cleanin are disconnect the product from mains PoS Pu should be cleaned with a moist cloth only never use aggressive cleaning agents solvents or benzine or cleaning Ensure that the product is completely dry before operating it again again after cleaning ATTENTION FRAGILE To avoid damage caused during transport wrap the product in its original packaging only and handle it with great care during transport Menu settings Main menu 01 Version brand model version number lamp use time 02 Address 001 512 Set DMX channel address 03 Pan reverse On Off On reversed Off normal 04 Tilt reverse On Off On reversed Off normal 05 Pan Tilt speed 01 16 From 01 16 to set the speed for Pan Tilt movement 06 Pan Tilt mode 8bit 16bit 8bit 16bit when set as 8bit the channels Pan fine and Tilt fine will be disabled the fixture has 14 channels now 07 Lamp mode On Off On lamp on Off lamp off 08 Reset 5 8 01 Lighting reset 02 Lamp time restore password Can be set password afterwards to prevent unwanted modifying 03 Motor Zero password Restore can be set password afterwards to prevent unwanted modifying 04 Exit 09 Channel data 01 Shutter 000 255 02 Dimmer 000 255 03 Lamp reset 000 255 04 Pan tilt speed 000 255 05 Pan 000 255 06 Tilt 000 255 07 Pan fine 000 255 08 Tilt fine 000 255 09 Color wheel 000 255
4. Beam 230W Hybrid USER MANUAL CE Congratulations on purchasing this 230W moving Beam Light Thank you for extending your trust in our technology 1 8 Voltage 110V 240V AC 50 60Hz Power Consumption 260W Lamp 7R 230W Osram DMX on off Lumen output 120000LM 10meter Color Temperature 8000K Lens 3 layer optic glass lens Prism 8 Prism rotation Gobo Gobo wheel with 15 1gobos Colors Color wheel with 13 1colors single rotation rainbow effect DMX Channel 20CH Frost function Control Master slave mode DMX Mode Auto mode Head movement Pan 540 16bit Electric correction Tilt 270 16bit Electric correction with auto correction function Focus Double automatic focusing Dimmer Independent dimmer channel 0 100 linear dimmer Strobe Independent strobe channel 1 13times s speed adjustable LAMP DMX ON OFF LAMP DMX ON OFF ignited by inverter protect and lengthen the lifetime of the bulb Other functions Fixture and lamp usage time display Highly Positioning precision Adjustable fan speed Built in analyzer for easy fault finding error messages Input signal isolating protection Body Size 47 33 27cm Net Weight 11Kg For reasons of safety and approval CE the personal reconstruction and or modification of this product is pn observe that damage caused by modifications performed manually to this device is not covered y the warranty This product leaves our works in a perfect condition Please observe all notes in these operating instru
5. MX PROTOCOL DMX Chart No Channel DMX value Description 1 Color Wheel 0 WHITE 5 WHITE RED 9 RED 13 RED ORANGE 18 ORANGE 22 ORANGE AQUAMARINE 26 AQUAMARINE 30 AQUAMARINE GREEN 35 GREEN 39 GREEN LIGHT GREEN 43 LIGHT GREEN 47 LIGHT GREEN LAVENDER 52 LAVENDER 56 LAVENDER PINK 60 PINK 64 PINK YELLOW 69 YELLOW 73 YELLOW MAGENTA 77 MAGENTA 82 MAGENTA CYAN 86 CYAN 90 CYAN CTO 260 94 CTO 260 99 CTO260 CTO 190 103 CTO 190 107 CTO 190 CTB 8000 111 CTB8000 116 CTB8000 BLUE 120 BLUE 124 BLUE WHITE 128 SLOW ROTATION 0 2rpm 2 Flash 000 009 Full off 010 049 Full on 050 089 Strobe from slow to fast 090 129 Pulse effect opening increasing 130 169 Pulse effect closing increasing 170 209 Random strobe with decreasing speed 210 255 Full on 3 Dimmer 0 255 Dark gt bright 4 Gobo 0 3 WHITE 4 7 Gobo1 8 11 Gobo2 12 15 Gobo3 16 19 Gobo4 20 23 Gobo5 24 27 Gobo6 28 31 Gobo7 32 35 Gobo8 36 39 Gobo9 40 43 Gobo10 44 47 Gobo11 48 51 Gobo12 52 55 Gobo13 56 59 Gobo14 7 8 60 63 Gobo15 64 67 Gobo16 68 71 Gobo17 72 113 Gobo rotation forward 114 117 Stop 118 159 Gobo rotation backward 160 166 Gobo2 Shake slow to quick 167 172 Gobo3 Shake slow to quick 173 179 Gobo4 Shake slow to quick 180 185 Gobo5 Shake slow to quick 186 191 Gobo6 Shake slow to quick 192 198 Gobo7 Shake slow to quick 199 204 Gobo8 Shake slow to quick 205 211 Gobo9 Sha
6. ctions to warrant this condition and the safe operation of hte product Any damage caused as a result of the non compliance with these operating instructions leads to the expiration of any warranty claim The manufacturer does not accept liability for any damage to property or for personal injury resulting from the improper handling of the product or non observance of the operating instructions Store these operating instructions in a safe place for later reference and pass them to any new holder when selling or lending or leaving this device in the hands of any other party Application According to Purpose This product is a lighting effect which creates specila light effects with one lamp Togenerate these effects the product must be connected to mains and a DMX 512 compatible controller This product is designed for AC110 240V 50 60Hz operation and exclusively for indoor use If used for any purpose other than described in these operating instructions the device D suffer damage and the warranty expires Also any other use is linked with risks such as short circuits fire electrical shock etc The manufacturer s serial number must never be removed as otherwise the warranty expires Notes on safety 1 Before Operation ATTENTION DANGER OF LIFE RISKOF FIRE RISK OF SHORT CIRCUIT Prior to the initial operation of this product please do the followings Read these operating instructions with great care Study and observe all inst
7. dity fog may reduce the protective insulation which may lead to fatal electric shocks The limit value for relative humidity is 50 at 450 A minimum distance of 1 5m to a fog machine must be observed fog saturation in the room must not reduce the visibility to below 10m The product must be operated at a temperature range of between 50 and 450 only Protect the product against direct exposure to sunlight or other heat such as from radiators If the product is taken from a cold environment into 3 8 a warm environment it must only be taken into operation once it has reached ambient temperature since the condensation created by the difference in temperature may destroy the device Protect the product against dust Dust may reduce the protective insulation which may cause fatal electric shocks The product must be operated at altitudes ranging between 20m below and 3000m above sea level only The product must not be operated during thunder storms risk of destruction from surge voltages The product must be operated at a minimum distance of 1 5m to lit objects only 5 Installation ATTENTION AN A RISK OF SHORT CIRCUIT This product can be operated suspended or as stand alone system Seed your lighting effect show any gans of damage do not install the device In this case have your lighting effect repaired by your specialized dealer The manufacturer does not accept responsibility or liability for damage to property or personal injury resul
8. e installation fixture must be as such that it can withstand for a period of 60minutes 10 times the load capacity without harmful deformation It als for any individual to unnecessarily stay or pass beneath the installation during any type of assembly wor The light effect unit must be secured by a safety arrester cable if fly mounted The cable must withstand 12 times the weigh of the light effect unit Use arrester cables equipped with quick closing links The dropping distance must not exceed 20 cm Defect arrester cables or arrester cables that have already been exposed to stress must not be used 6 Operation ATTENTION RISK OF SHORT CIRCUIT Controls Link all DMX devices with a DMX 512 controller by using a standard 3 pin DMX cable Connect the output of the first device with the input of the second device and the output of the second device with the input of the third device and so on Connect the mains plug to an outlet Operating the product for the first time may generate smoke and odour this is not a defect Avoid dis connecting the product repeatedly and quickly from with mains Always wait 15 minutes prior to the next dis connection The device starts not until a self testing and starting time If the moving head is ready to start push and roll the function wheel The LCD display shows the options as below 7 Lamps ATTENTION AN A N DANGER OF LIFE RISKOF FIRE RISK OF SHORT CIRCUIT 10 During operatio
9. faces and objects must maintain a minimum distance of 3m to the housing Walls must maintain a minimum distance of 50cm to the housing The device must be installed on a fireproof surface only no carpet 1 Always ensure a proper circulation of air Do not touch the housing during operation it will heat up The housing is safe to touch approx 5 minutes following the end of operation The device must never be carried via the projector anns Use the caring handles only Fluids must not enter the housing as this could reduce the protective insulation and may trigger short circuits which may lead to fatal electro shocks If fluids have entered disconnect the mains plug immediately and secure the product against unintentional operation and contact yours specialized dealer Damage caused as a re suit of fluids entering the housing is exempt from warranty No metal parts or other items must enter the housing as this may reduce the protective insulation or trigger short circuits which may lead to fatal electric shocks If metal parts or other items have entered disconnect the mains plug immediately secure the product against unintentional operation and contact your specialized dealer Damage caused by metal parts or other items in the housing is exempt warrantably 4 Operating Environment ATTENTION AN A N DANGER OF LIFE RISKOF FIRE RISK OF SHORT CIRCUIT The product must be operated and stored in a dry environment only Splash water rain humi
10. ke slow to quick 212 217 Gobo10Shake slow to quick 218 223 Gobo11 Shake slow to quick 224 230 Gobo12 Shake slow to quick 231 236 Gobo13 Shake slow to quick 237 243 Gobo14 Shake slow to quick 244 249 Gobo15 Shake slow to quick 250 255 Gobo16 Shake slow to quick 5 Prism 0 127 No prism 128 255 Prism 6 Prism 0 0 rotation 21 90 T 180 ko 270 84 3 105 360 127 450 128 190 540 191 192 Prism rotation forward 193 255 Stop Prism rotation backward 7 Effect 0 255 Blank 8 Frost 9 Focus 0 255 10 Pan 0 255 11 Pan fine 0 255 12 Tilt 0 255 13 Tilt fine 0 255 14 Function 0 11 UNUSED RANGE 12 24 PAN TILT FUNCTION FAST 25 37 NORMAL 38 50 CONVENTIONAL 51 62 LINEAR 63 255 UNUSED RANGE 15 RESET 0 25 NO 26 76 EFFECTS RESET 77 127 PAN TILT RESET 128 255 CICOMPLETE RESET 16 Lamp 0 25 No function 26 100 Lamp Off 101 255 Lamp On 17 Pan Tilt speed 0 255 Pan Tilt Pan fine Tilt fine 18 Colour time Foedus wn immer Frost Prism 19 Beam ume Static Gobo 20 Gobo time 8 8
11. n the lamps will reach temperatures of up to 600 C Touching the lamps may cause serious burns Objects coming into contact with the lamps during and shortly after operation may catch fire Disconnect the product from mains prior to installing or before changing a lamp Allow a lamp to cool for approx 15minutes before exchanging it Never touch a lamp with bare hands If damaged or deformed a lamp must be exchanged When exchanging the lamp be sure to use suitable lamps only Lamps with greater performance generate excessive heat for the product risk of fire Damage resulting from the use of an unsuitable lamp is exempt from warranty Never connect the lighting effect to the mains prior with opened housing 8 Fuse AN A ATTENTION DANGER OF LIFE RISKOF FIRE RISK OF SHORT CIRCUIT Disconnect the product from the mains prior before changing a fuse oe the fuse by a fuse of same type and rating An incorrect fuse could damage of destruct the lighting effect Replace a fuse by levering the fuse holder cover with an appropriate screwdriver Remove the old fuse and place the fuse inside the holder Replace the fuse holder and insert it Never connect the lighting effect to the mains prior with opened housing 9 Cleaning ATTENTION AN A DANGER OF LIFE RISKOF FIRE RISK OF SHORT CIRCUIT The product must be freed regularly from dust other deposits and contamination as this may reduce the protective insulation which may lead to a fatal
12. ructions carefully Ensure that everybody and anybody involved in the installation operation transport and storage of this product is suitably qualified 2 8 Verify whether any visible damage was caused during transport If the power cord housing or the light are damaged do not operate the device contact your specialized dealer immediately 2 Supply Voltage Mains Cord and Connection to Mains The handling of supply voltage mains cords and connections to mains calls for particular care considering the risk from a ee electric shock the risk of fire and the risk of short circuits please observe the following notes in particular Products operating on supply voltage should be kept out of the reach of children Therefore ensure the permanent supervision if children are in the immediate vicinity of the product For commercial facilities the regulations on the prevention of accidents of the respective trade association must be observed The operation of this equipment at schools training facilities and hobbyorself help workshops must be supervised responsibly by trained personnel Check the product regularly for any damage to the mains cord Should you discover any damage to the malns cord do not operate or disconnect this product Secure the product against accidental operation and contact your specialized de alert Always separate the product from mains by holding the mains plug by the handling surface Never disconnect by holding the line cord
13. ting from an improperly installation As a stand alone system the device must be installed vertically on an absolute planar firm fireproof shock and vibration free surface The installation of this lighting effect must be carried out by trained and professional staff The installation of this lighting must only be carried out with the appropriate materials The suspended installation of this lighting effect necessitates a suitable suspension system The lighting effect must never be fixed swinging freely in the room No individuals should linger underneath the lighting effect during suspended installation It is a must to install this device with a second independent fixture Such second fixture must guarantee in the event of failure of the main fixture that no assembly parts will fall down Use the fixture on the undersurface only The ont effect unit must be attached via two certified hooks and omega bracket to a tie bar system Use the screw threads on the undersurface only It must be ensured that an expert inspects the mechanical and safety relevant installation prior to the initial operation and following major modifications prior to the renewed operation It must be ensured that an expert inspects the mechanical and safety relevant installation at least once a year It must be ensured that an expert inspects the mechanical installation and the installation of relevance to safety within the framework of an acceptance test at least every four years Th