Home

PW16 User Manual

image

Contents

1. Initiates display of events from memory lt ENTER gt cancels memory readout Enable or disable chime function Activates or deactivates outputs and devices Activates program mode to add or change Users codes Displays events and automatically scrolls to the next event every 2 5 sec Use lt MEMORY gt key to scroll up manually Only if enabled by installer Press lt Control gt for 2 seconds For details see page 12 Note If you started an operation incorrectly press ENTER to exit and return to the previous mode O peration How to Arm the System before Exit e Preparingthe Systemfor Arming Verify that all zone indicators are off when all zones are closed all doors exits and windows are closed and motion in the protected area is restricted or bypassed the System is ready to be armed If one or more zone indicators are illuminated it displays the open zones Close open zones or bypass them Bypass any zone you cannot close Bypass indicator flashes indicating bypassed zone s For details see page 9 Note Bypassed zones are not protected e Arming the System Before leaving premises the system has to be armed Arming the alarm system will turn on all detectors in the partition s being armed Enter user code and then lt ENTER gt to arm the system There is a exit delay prior to the system being armed During this delay time a slow beeping is heard to indicate that th
2. the first thing that will always be displayed is the system messages If the system led turns ON but no other Zone LED s are ON at the same time this means that there are no current system alarms If a zone LED and LED s are ON then this indicates system alarms that have not yet cleared The LED s 1 8 are pre defined as to what system alarm they will display These system alarm indications are shown in the table below LED 1 Battery Low LED 5 Radio Pendant Battery Low LED 2 LED 6 Supervised Detector Failure LED 3 Telephone Line Failure LED 7 Zone Inactivity Timeout LED 4 Radio Detector Battery Low LED 8 Dialer Kiss off Failure Following the display of current system alarms the panel will then sequence through the 255 historical memory events starting at the most recent event The second table shows the alarm events that can be displayed in memory mode and what indicators are used to show them 11 How to Read Trouble Messages Any failure or abnormal events that may occur are indicated by trouble messages and the Trouble indicator is lit Press MEMORY to read out messages and other events stored in memory How to Display Events from Memory The system memory stores the last events Press MEMORY to display list of events Following the display of current system alarms the panel will then sequence through the 255 historical memory events starting at the most recent event The second table shows the al
3. control Functions User code can change dialer telephone numbers User code can alter the real time clock J User can answer an incoming call and start up down load User can allow access to installer program mode from client mode Initiate Walk test mode How to Change Master Code While in CLIENT mode Press lt PROGRAM gt and 1 to change Master code press ENTER the code digit will be flashed back to you Use the numeric keyboard to enter your new Master code The code can hold any combination of 1 to 6 digits It is recommended using a multi digit code Press ENTER to save your new code the new code will be flashed to you and 3 short beeps to indicate correct entry or 1 long beep if not accepted Press lt PROG gt and ENTER exit user Code Program mode How to Add or Change User Code While in CLIENT mode press lt PROGRAM gt and the User number 2 to 50 to add or change the code press lt ENTER gt If there is an existing code already it will be flashed back to you Use the numeric keyboard to enter the new code The code can hold any combination of 1 to 6 digits Entering the new code will delete the old code Press lt ENTER gt to save your new code the new code will be flashed to you and 3 short beeps 15 Repeat the procedure for all users Press lt PROG gt and ENTER to exit Local Program mode How to Delete User Code In client mode press lt PROGRAM gt and the User number 2 to 50 you
4. leave the premises If you wish to stay or that no one will enter the protected premises you may cancel the Entry exit delay by pressing the ENTER key The slow beeping stops and the system is immediately armed The A B or C indicator flashes to indicate that the system is armed in stay mode The indicators may go out a few seconds after exit delay expired depending on the installer s setting e Disarming the System Enter user s code and press lt ENTER or press lt STAY gt if enabled by installer The A B or C indicator goes off to indicate that the system is disarmed How to Arm Partitions The protected area can be grouped into 3 separate partitions A B C The system can be grouped for User s convenience to separate in a business environment the offices from the warehouse area or in a private residence the different rooms of the home e g living room bedroom etc To arm partition A enter user code for partition A To arm partition B enter user code for partition B To arm partition C enter user code for partition C Note to arming partition with code see page 8 How to arm the system before exit During exit delay you can leave premises At the end of the procedure the A B or C indicator lights up to indicate that the partition A or and B or C is armed The indicators may go out after a few seconds depending on the installer s setting To disarm partition see Disarming the System 9 How to Bypass Z
5. lt 823 gt ENTER 1 7 lt ENTER gt Where 1 7 the current day 1 Sun 2 Mon to 7 Sat Press PROGRAM 824 ENTER lt HHMM gt ENTER Where HH Hour in 24 Hour Format and MM Minutes 16 Press lt PROGRAM gt lt 825 gt lt ENTER gt lt 1 31 gt lt ENTER gt Where 1 31 the current date Press lt PROGRAM gt lt 826 gt lt ENTER gt lt 1 12 gt lt ENTER gt Where 1 12 the current month Press PROGRAM lt 827 gt lt ENTER gt lt YY gt lt ENTER gt Where YY current year e g 02 2002 How to operate the access control output If the alarm system has been set up to allow control of an electric door lock you can activate the door release function as follows Press CONTROL or Press lt CONTROL gt enter CODE then lt ENTER gt The Control LED will lights up while the lock is active and turn off as soon as power is removed from the lock The Access Control function can either be a single button operation or restricted to requiring a valid User code entry Both options are shown above Please consult your installer as to what option may be programmed How to start Walk test Mode While in CLIENT mode a User with the proper authority can start walk test mode This special mode latches the alarm signals from detectors at the keypad initiating the test so that one person can trigger every detector connected to the alarm then return to the keypad to verify operation On terminating Walk test mode the
6. test results are put into the memory buffer so they can be viewed at a later time To start Walk test mode while in CLIENT mode press PROGRAM 836 lt ENTER gt The keypad buzzer will beep at 1 second intervals Next trigger every detector connected to the panel then return to the keypad and all of the zones that were triggered will be displayed at the keypad To terminate Walk test mode press ENTER The keypad will stop beeping and automatically exit CLIENT mode How to Answer an in coming call From time to time your installer may need to access the alarm from a remote PC to make changes to your programming and for security reasons they may have configured the alarm so that an authorized person onsite is required to make the alarm system answer the in coming call This option is only available in CLIENT mode 17 To answer an In coming Call press PROGRAM lt 835 gt lt ENTER gt Provided the line connected to the alarm was ringing at the time the panel will now answer the call and allow a remote PC connection How Remote command control works Another powerful feature available from your alarm is Command Control This feature is a remote control facility which allows valid users to access the panel via a standard touch tone telephone and check or change the Arm Disarm status of each of the areas operate each of the eight outputs or turn on an optional Microphone The Command Control feature is only available on pan
7. B is Armed AREA B On Steady ARMED ARMEDC Area C is Armed AREA C On On Steady ENC LIN MODE A Area A STAY Mode AREA A fag ON STAY MODE B Area B STAY Mode AREA B Flashing ON STAY MODE C Area C ee Mode AREA C Flashing DURESS ALARM Duress Alarm TAMPER Flashing LINE Flashing At keypad LED s 1 8 On Steady SUPERVISED RADIO ALARM Supervised Radio Bypass Flashing Passive Infra R assive Infra Red AMPER Flashing LED s 1 16 On Steady 13 ZONE INACTIVITY ALARM Zones 1 16 LED s 1 16 On Steady TAMPER Flashing CONTROL Flashing TELEPHONE LINE FAILURE Phone Line Failure LINE On Steady EXCESSIVE RE TRIES Panel Dialer LINE On Steady LED1 On Steady FAILURE TO GET A KISSOFF Panel Dialer LINE On Steady LED2 On Steady WALKTEST MODE Manual walk test MAINS On Steady mpag BATTERY On Steady LINE On Steady LED s 1 16 On Steady How to Control Outputs and Devices The keypad enables control of external devices such as an air conditioner or heater To activate or halt a device press lt CONTROL gt Control LED lights up steady press the number of the device up to 8 different devices can be controlled via the keypad then press ENTER to activate or deactivate the selected device To check what outputs are ON simply press the CONTROL key LED s corresponding to device ON lights up Press ENTER to return to normal mode How to Get into to User Program Client Mode There are 2 levels of program m
8. This feature works the same way that Directly Controlling an Output works see page 14 only it requires a code to access the function 19 Warranty CROW LIMITED WARRANTY Crow warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose numbers are printed on the printed circuit board inside his product Crow s obligation is limited to repairing or replacing this product at its option free of charge for materials or labor if it is proved to be defective in materials or workmanship under normal use and service Crow shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other then Crow There are no warranties expressed or implied of merchantability or fitness for a particular purpose or otherwise which extend beyond the description on the face hereof In no case shall Crow be liable to anyone for any consequential or incidental damages for breach of this or any other warranty expressed or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by Crow s own negligence or fault Crow does not represent that this product can not be compromised or circumvented that this product will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that this product wil
9. a A Once the code 2045 has been received the panel checks the current status of Area A and replies with the pre programmed voice message relating to that status e g if Area A is Armed then the Armed message will be sent if Disarmed then the Disarmed message will be sent If only the DTMF board is fitted the voice message is substituted with a long beep if Area A is Armed and three short beeps if it is disarmed Once the status message has informed you of the actual state you can use the key to toggle the option on amp off or Arm and Disarm e g in our example above code 2045 accesses Area A arming or disarming Assuming the status message we received was Area A alarm is Armed If we press the key Area A will be Disarmed and we would receive a status message Area A alarm is Disarmed or whatever message is programmed by the installer While you are on line with the panel you can move between menu options by entering the code of the option you want to control Assuming there was a code of 4321 programmed to control outputs After having used code 2045 to control the Arm Disarm 18 status of Area A we first press the button to reset all previous entries Then we can enter the digits 43215 that is 4321 as the code to control outputs and 5 to select output 5 The current status of output 5 will be given either by the voice message or the appropriate tone and then the status can be changed w
10. arm events that can be displayed in memory mode and what indicators are used to show them The system will display the last event and automatically scroll to the next one every 2 5 seconds and a beep is emitted Use the arrow keys to scroll up manually Wait until all messages are displayed or press ENTER to cancel memory readout EVENT TYPE DEVICE INDICATOR STATUS ACTIVATION Zones 1 16 LED s 1 16 On OnSteady BYPASS Zones 1 16 Pus EU Steady Dmm DETECTOR TAMPER Zones 1 8 TAMPER Flashing memo cere eem DETECTOR TAMPER Zones 9 16 TAMPER Flashing ee Et WRONG CODE ALARM Code at Keypad TAMPER On Steady p ieee oan CABINETTAMPER TAMPER Flashing RE al TAMPER SWITCH Tamper alarm at TAMPER ES Steady k eypad LED s 1 8 On Steady 12 LOW BATTERY Controller Battery BATTERY Flashing MAINS FAILURE Controller Mains MAINS Flashing Supply FUSE FAILURE F1orF2 Controller on board MAINS Flashing RE RADIO ZONE LOW BATTERY Radio Zone 1 16 BATTERY Flashing rna ise coca PENDANT LOW BATTERY Radio Key User 1 20 BATTERY Flashing RN eee ane coca PANIC BUTTON or Keypad Panic LINE Flashing BUTTONS 1 amp 3 PRESSED TOGETHER At keypad LED s 1 8 Flashing FIRE ALARM BUTTONS 4 amp 6 Keypad Fire LINE Flashing PRESSED TOGETHER CONTROL Flashing MEDICAL ALARM BUTTONS Keypad Medical LINE Flashing 7 amp 9 PRESSED TOGETHER BYPASS Flashing ARMED A Area Ais Armed AREA A On Steady ARMED B Area
11. at Chime is disabled To enable Chime mode press lt CONTROL gt and PROGRAM Control LED goes off to indicate that Chime is active Emergency Alerts This three special key s function is best programmed by your installer to suit your individual situation Most commonly it is used in a panic situation These are a PANIC FIRE and MEDICAL alarm When using the LED keypad the Panic alarm can be generated by either the single Panic button or by the simultaneous operation of two buttons Pressing two buttons simultaneously generates the Fire and Medical alarms How to initiate Panic Press the lt PANIC gt or Press simultaneously lt 1 gt and 3 10 How to initiate Medical Alarm Press simultaneously 7 and 9 How to initiate Fire Alarm Press simultaneously lt 4 gt and 6 Generate Threat or Duress If you are compelled to disarm the system under threat you must enter the duress digit before the user s code to activate the automatic dialer The duress digit shifts up your usual code by one digit If your code is 345 and 8 is your duress digit than entering 8345 will modify your code The modified duress code will disarm the system in a normal way but at the same time will activate the dialer silently to report a duress event without arousing suspicion For details ask installer How to Read System Messages When viewing the memory events at the keypad by pressing the MEMORY gt
12. dias ELECTRONIC ENGINEERING LTD PowerWave 16 16 zone Control panel Communicator Users Operating and Programming Guide Version 6 20 P N 7121240 Rev B N A July 2002 Contents Nigerian 4 Meet the Crow Alarm Control System 4 Typical Alarm System Configuration 4 Keypad Deseript OD cs ue tiae dee o erede dp ie e ede ord 5 FUNCHION Keys cce reete RU D OO RD ADT DH 5 Alphanumeric Keys cto bip eeu tpa ana Det 5 Nudible Signals 4 cubilia acne avo pp eed as 6 l nidIGat OF s scent rennen eene endo pe en re enn rere 6 Zone and Status indicators LEDs b 16 eee 6 Partitions indicators LEDs A B i Cieipin rinmi anaa N 6 Armed indicator Memory indicator Bypass indicat OF eee 6 Program indicator Aux indicator Mains indicator sse 6 Tamper indicator Battery indicator Line indicator Control indicator eien seis Attra cat eaten an onimane AAN G T 6 Summary Of FUNCTIONS iiics eret tenet t ten i e avai Eat 6 Operation s mto een ih E bete pg dui 8 How to Arm the System before Exit nennen 8 How to Arm the System when Staying Home sese 9 How to AT mm Partltlons uice creer eap edd o 9 Howto Bypass ZONES anin a oce m eee tenter i de ne oe en ge 10 How to use Chime If enable by Installer eee cesses e 10 Emergency Alert S sire ern e io n RR E EAR ERR RR e 10 Generate Threat or DUre5s acc eget moco n pps ie Pes 11 How to Read System Messages sssssssssseeeeneene nennen nennen nns 11 Ho
13. e system is not armed yet and reminds you to leave the protected area The A Bor C indicator lights up to indicate that the system is armed The indicators may go out few seconds after exit delay expired depending on the installer s setting If you must disarm the system during the exit delay press lt ARM gt e Quick Arm When enabled by the installer Press lt ARM gt to arm the system The A B or C indicator lights up to indicate that the system is armed During exit delay time a slow beeping is heard reminds you to leave the protected area e Disarming the System Enter User s code and press ENTER The A B or C indicator goes off to indicate that the system is disarmed e Stopping Resetting Alarms In case of an alarm condition Enter User s code and press ENTER to stop alarm any time and turn off any audible sirens How to Arm the System when Staying Home e Arming the Systemin Stay Mode This type of arming is used when people are present within the protected area At nighttime when the family is about to retire perimeter zones are protected but not the interior zones Consequently interior movements will be ignored by the system To arm Stay mode press lt STAYs gt enter user code and then lt ENTER gt The A B or C indicator flashes to indicate that the system is armed in stay mode Q uick Stay When enabled by the installer press lt STAY gt to arm the system During exit delay you can
14. els fitted with a Voice or DTMF board The Voice board provides voice prompts to guide you through Command control operations whereas the DTMF board provides tones one Long Tone for ON or three short beeps for OFF Please talk to your installer to find out if all or any of these options are available on your alarm To perform any of the Command Control features you must first ring the phone number which the panel is connected to The panel may be set up to answer after a specific number of rings of it may be set up to use a fax defeat option Either way when you ring the phone number and the panel answers the call the first thing you will hear over the phone is a burst of modem tone for two seconds After this tone has stopped you must enter the access code which is associated with the Command menu option you wish to access Remember the code you enter will determine which menu option you access If you miss the pause the panel will repeat the modem tone and then again pause for 5 seconds looking for your access code This process will be repeated 4 times before hanging up if no valid code is received When entering codes or other information in Command Control the key acts as a Clear button When you have entered the required 4 digit access code the panel will reply with the status message associated with the Command Control function you have accessed For example lets say we have a code of 2045 to allow Arming amp Disarming of Are
15. ent site Up to 8 keypads can be integrated into the system Access levels and Users access codes are detailed below Keypad Description The LED Keypad shows all the information required to operate the system The User communicates with the alarm system via the keypad The Keypad displays continuous information about the status of the alarm system and enables the User to operate the system in different modes change settings and program Users access codes The keypad also collects and records events to be displayed afterward on request to overview system activities and to analyze system performance for diagnostics Function Keys These keys are used to arm the system enter commands to alter system settings or scroll through the history events ARM STAY BYPASS PROGRAM CONTROL MEMORY PANIC ENTER ORE HSH O P e D IB 3 A Alphanumeric Keys These keys are used to enter codes Initiate Emergency or for programming 5 Audible Signals The keypad emits signals beeps in response to User activities These signals are listed in Table Table List of Audible Signals Sound Sequence Description Illegal operation or wrong key pressed Slow beeping Through the Exit or Exit or entry delay warning when arming Entry delay time the system indicates that you must exit the protected area also Entry delay warning when entering via the entry zone to disarm the sys
16. hone Arm or disarm the whole house or just one area all with your own voice confirming your selections Imagine turning on the spa before leaving work so it is hot when you get in the door The under floor heating has just automatically switched on using the on board timer and you have just opened the rollerdoor and disarmed the garage from your cell phone so the white ware repairman can work on your washer The controller will support a 16 LED keypad or the more sophisticated LCD liquid Crystal Display keypad It also has a comprehensive alarm event memory that stores all of the controller activity with the time and date Typical Alarm System Configuration The protected premises can be divided up to 16 zones as defined by the installation scheme The protected area can be grouped into 3 separate partitions A B C The system can be grouped for User s convenience to separate in a business environment the offices from the warehouse area or in a private residence the different rooms of the home e g living room bedroom etc Each zone can react differently to various events to generate an alarm or activate a device The system can be armed in two different modes 1 Arm the protected areas are entirely vacated 2 Stay people and pets populate the protected areas The User who has access to the key pad s control features can change the settings The system can be accessed via multiple keypads each located at a differ
17. intend to delete press lt ENTER gt The code will be flashed back to you Press BYPASS to delete User code Press lt ENTER gt to save the change Press lt PROG gt and lt ENTER gt exit program mode How to Add or Change Telephone Numbers Your panel will accept up to 6 phone numbers with a total of 16 digits Your panel can be can be programmed to dial all or any of these depending on the event which has occurred The six phone numbers are at program address 331 through to 336 While in CLIENT mode key in the following sequence lt PROGRAM gt 331 ENTER The address for telephone number 1 The existing number will be flashed out at the Keypad then enter NEW TELEPHONE gt ENTER The new numbers will be flashed back to confirm acceptance At any time you can enter in the address for the telephone number just to view the currently programmed value then press the PROGRAM button to move on to another address Note Address 331 PH 1 332 PH 2 to 336 PH 6 Note on the LED keypad 0 is indicated by LED A and 9 by LED B How to set Time and Date The alarm system has an internal clock that may be used to automatically Arm or Disarm the alarm or turn Outputs On or off It is also used to identify when events occurred in memory via the LCD keypad Should you need to change the Time amp Date it must be done from CLIENT mode To change the Time amp Date press Press PROGRAM
18. ith the button on the remote telephone Note For output control you must enter in the 4 digit code e g 4321 followed by the output number you wish to control in this case 5 At any stage if you enter in an incorrect code you can press the button on the remote telephone to clear all code entries and then start again To turn on the optional Microphone only available if the Voice Board is fitted you must enter in the appropriate code followed by the button To turn the Microphone off you simply press the button again To end a Command Control session simply hangs up the phone The panel is monitoring the line at all times and 15 seconds after the last key press it will automatically hang up the line This 15 second timer is active during the whole command control process so a period of 15 seconds without a key press will cause the panel to hang up How Local command control works If a command control code for outputs is programmed and the output s are allowed to be locally controlled from the keypad then entering the 4 digit code at a keypad will blank the display and the zone LED s will now indicate the output status e g if output 1 is on zone 1 LED will be on By now pressing the 1 button at the panel keypad output 1 can be turned off provided it is allowed to be locally controlled To leave local command control mode simply press the ENTER button and the keypad will return to normal operation
19. l in all cases provide adequate warning or protection Purchaser understands that a properly installed and maintained product can only reduce the risk of burglary robbery or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result Consequently Crow shall have no liability for any personal injury property damage or any other loss based on claim that this product failed to give any warning However if Crow is held liable whether directly or indirectly for any loss or damage arising under this limited warranty or otherwise regardless of cause or origin Crow s maximum liability shall not in any case exceed the purchase price of this product which shall be the complete and exclusive remedy against Crow 20 Use the following form to record your changes and customizations Zone Name N Device Designation al col ll tol ol r oj e cof Lo CO N 00 9 al oF l LO c r e 9 ol ol o x l ol N o o a aas iaa iaa aaa aa aa han Poel Uae AY e A A A A A A QI A e e e e e e e 09 e e 22
20. ode CLIENT mode and INSTALLER mode Normally the installer will give you access to the CLIENT mode so you can add delete or change the user codes If you request it your installer can provide you with access to the INSTALLER mode as well To get into CLIENT mode provided the system is NOT armed Press PROGRAM enter Master code and ENTER The Program indicator lights up to indicate that the system is in User programming mode If you get a single long beep at this point and the Program LED doesn t turn on it means your code cannot access Program mode e Howto exit program mode To exit out of program mode press lt PROGRAM gt and lt ENTER gt The Program indicator goes off to indicate that the system is not in User programming mode 14 How to Change or Add Codes About Master code and User code The factory default master code 123 is intended as a preliminary control of the alarm system After PowerWave is installed and put into service the code can be changed to any code known to the Master user The Master user can define up to 49 user codes To limit access rights the holder of the Master code can ask the installer to define several User profiles Access rights are listed below User code has Area A and or B or C permission User code can arm and or disarm arm an area User code can arm and or disarm arm an area in Stay mode User code can change its code User code can change user s code User code can Operate
21. ones Bypass any zone that cannot be closed You can bypass selected zones prior to arming It is also used to temporarily exclude a faulty zone from service which requires repair To bypass a selected zone press lt BYPASS gt Bypass indicator lights up to indicate that the system is in bypass mode Enter the zone number e g 01 05 12 one or more zones the zone LED indicators lights up to indicate that the zone is bypassed following press lt ENTER gt the Bypass LED flashes to indicate zone s bypassed While in the Bypass mode it is possible to bypass more than one zone press BYPASS Bypass indicator lights up to indicate that the system is in bypass mode Add the zone number e g 03 one or more zones the zone LED indicators lights up to indicate that the zone is bypassed following press ENTER the Bypass LED flashes to indicate zone s bypassed To un bypass zones press BYPASS enter zone number e g 07 13 the zone LED indicators goes off to indicate that the zone is un bypassed and ENTER Note Disarming automatically un bypasses all zones How to use Chime if enable by Installer A Chime Day zone is a detector that can be part armed while you are at home but working in another part of the building It can be programmed to operate a buzzer or light to let you know y ou have a visitor To disable the Day chime zone press CONTROL and PROGRAM Control LED indicator lights up to indicate th
22. tem ndicators There are 30 LEDs indicators show the status of the system Zone and Status indicators LEDs 1 16 Partitions indicators LEDs A B C Armed indicator Memory indicator Bypass indicator Program indicator Aux indicator Mains indicator Tamper indicator Battery indicator Line indicator Control indicator Summary of Functions The system s main functions are listed in table CR Kus Ben Nowe Full Initiates full arm or Partition Arm Full Arm Initiates full arm FI by gt mi Disarm Disarms the Only when slow beeping during exit system during is emitted exit delay Disarm OD Disarms the Stopping Alarms 6 Feo Kayo Bee Nowe Arm Stay rm dd gt Gi pq Initiates partial alarm when the user is home Initiates partial alarm when the user is home Only if enabled by installer Disarm OD ENTER Disarms the c Aajo Geen Disarm Disarm STAY Disarms the system cr E 2e cr s Bypasses a zone s Repeats the procedure to un bypass zones Initiate dx Activates panic Panic alert Initiate CC 1 j 3 Activates Only if enabled by emergency BI Initiate Medical Activates emergency alert Only if enabled by installer Initiate Fire lt gt C4 C6 Activates Only if enabled by Alarm emergency alert installer NE Crime PET eem Enable dis able Control gt Ceara Bev gt Gum Change or Add Users code gt Gn c MPE gt GR
23. w to Read Trouble Messages sese 12 2 How to Display Events from M emory eene 12 How to Control Outputs and Devices eene 14 How to Get into to User Program Client Mode 14 How to Change or Add Codes rr tpe epp 15 How to Change Master Code eie ec PPP HR ER 15 How to Add or Change User Code sess eene 15 How to Delete User ode tenute 16 How to Add or Change Telephone Numbers eee 16 How to set Time and Date inpet dice detente 16 How to operate the access control output nnn 17 How to start Walk test ModE iue rm e e eese o He 17 War alb ys ette er inp De OUT EP ERU URP ru dE DER PURGE ees 20 ntroduction Meet the Crow Alarm Control System Thank you for choosing to protect your premises with a PowerWave 16 PW16 of Crow Electronic Engineering Ltd Power Wave of Crow Electronic Engineering Ltd is a highly advanced multifunction alarm control system designed to flawlessly manage your security system at home or at business protects you against burglary and supports the operation of electronic devices The PW16 has many incredible program options and additional accessories that can enhance the standard features of the panel from simple Home Automation to Radio control and Voice Prompted Command control Please ask your installer to find out more about these powerful features You can phone your home to check or change the status of any output using the keys on your p